Document Evo1V3oqKDp7pMRdrmLD46Y7N
Hoffman Specialty Co., Inc.
Specialties, Heating
Hoffman Kompo-Gage
HOFFMAN KOMPO-GAGE
Measures pressure up to 30 lb., vacuum to 30 in. Pressure is registered in ounces up to 5 lb. Vacuum is shown in half inches up.to 10 in.
Used in Hoffman "Controlled Heat" installations or in onepipe gravity vacuum systems equipped with No. 2 valves; in dicates efficiency of the apparatus when a warm house is main tained with vapor at temperatures considerably below 212 deg.
The No. 12 Hoffman Blast Trap is adapted for draining condensation from Indirect
Radiators, Dryers, Drums, Blast Coils, Unit Heaters, Hot Water Generators and
Ends of Long Steam Mains or Risers.
.t
The Trap embodies the desirable feature of open bucket or float traps because it
relieves condensation immediately upon its arrival at the trap regardless of the water
temperature. Coupled with the float is a thermostatic member which positively over
comes the chief difficulty with float traps by automatically relieving air as well as
condensation from the system.
No. IS Hoffman Blast Trap
Table of Nominal Capacities, No. 12 Hoffman Blast Trap
Pressure; Pounds per Square Inch.. V4 Capacity, Pounds per Hour............ 800 Capacity, Square Feet Radiation.. 3200
1000 4000
2 1500 6000
3 1800 7200
4 2000 8000
5 2500 10000
Maximam Operating Pressure, 30 lb. Capacities for oyer 5 lb. pressure, furnished on application. With Strainer: inlet connection, 1 in.; outlet, 1 in.
On the basis of K lb. of condensation per square foot per hour.
i No. 19 Quick Opening Hoffman Radiator Valve is of the semi-packless type for
vacuum pump installations or for vapor systems, where modulation is. not required.
Made in % in. size only,
capacity up to 200 sq. ft.
C.I. Radiation. Regularly
furnished in Lever Handle
pattern. Wood Wheels or
Lock Shields furnished on
special order without extra
charge. Extension stems
supplied at an extra charge.
No. 18 Hoffman Radiator Trap
No. 19 Hoffman Radiator ValK
No. 18 Hoffman Return Line Valve or Radiator Trap
is similar in principle to the No. 8 Valve. It is intended
for pressures up to 15 lb. and radiators up to 100 sq. ft. Thermostats are interchange
able and made of special Hoffman Diaphragm Metal that will not soften, stretch of crack
under repeated action. Made with x/i in. connections in Angle, Straightway, Right-
and Left-hand Offset Patterns. For roughing measurements see page (802).
Write for Descriptive Circulars
804
Specialties, Heating
TYPICAL INSTALLATION HOFFMAN "CONTROLLED HEAT" EQUIPMENT
.. ^cfTT)
TYPICAL HOFFMAN CONTROLLED HEAT" INSTALLATION.
NOTE.--Loop discharges into high end of return main. This results in venting airfrom high point tn return instead oflout point. Point^W" shouldbeat least iiin.aboveutaterlineutilk Nos. 0 and0 loopsandSOin. with Nos. 03 and 04-
NOS. 20 AND 21 HOFFMAN THERMOSTATIC STEAM TRAPS
Pressure Range 0 to 100 lb. Without Change or Adjustment
The Hoffman Steam Trap Body is of strong, rugged all bronze construction. The diaphragms in the thermostat, the valve pins and valve seat are all made of the
same non-corrosive alloy which has been successfully used for diaphragms in Hoffman Valves for a number of years. The alloy withstands high temperature steam, and repeated action without softening or cracking. It also withstands the
scoArinsgtraaicnteiornisofbustieltamin.to the trap body permitting ready removal for cleaning. All renewable parts are interchange able, permitting replacement without adjustment of any sort. The trap is built to give maximum service with minimum attention and when repairs or cleaning are required the work
can be quickly done. The Hoffman Steam Trap normally has a wide open
vent port which is maintained until all air and condensation is relieved from the system, after which steam contact with the thermostat closes the port. No hand operated by-.
Hot. to and tl
Hoffman Thermostatic steam Trap
passes are required to vent air from the system. The trap
canTnohteadiri-sbcihnadrgoer cfraepeazec.ity is dependent upon differences between the temperature of
condensation delivered to the trap and steam temperature, the greater the difference the larger the capacity of the trap. The following table gives continuous discharge capacities
in pounds per hour.
NO. 21 TRAP
NO. 20 TRAP
Pressure, lbs. per sq. in....... |
Temperature Drop 20....
275
Temperature Drop 35..
725
550 715 1580
70 820 1675
900 1830
100 925 1860
375 950
30 725 1410
50 l 70. 90 1 100 925 1085 1190 1225 1860 1 2250 I 2490 2550
No. 20 Trap has K in. pipe connections, & in. port. Weight 3}4 lb. No, 21 Trap has in. pipe"connections, 3 in. port Weight 3% lb.;