Document EvDQeYMeNoEzM12KgQN3EdGbL

INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION south charleston plant S.icanes e^a LHetTisnt P.O. BOX BOO^, SOUTH CHARLESTON, WV 25303 DeanJ.R.Tc (Ns'rie'l Locetion Area Ccy tO Mailing Lists A-1, A-2 P.L. Vevenick M.E. Knopp W.R. Mannia W. B. Spunlock att Nov. 1, 1984 . O^ig^at-rig Ofect A-es Babied Wintenization Insulation Attacked is a status nepovt cfi the. Wintenization Insulation that is being penionmed in the South Chanleston Plant. Report mitt be iss ued meekly to show horn we (Uie pnognessing on the estimated Insulating monk nequinea ion. Wintenization. Note thene is a column on nepont ion. Add Ons to anginal Winteniz>' ing List. This column could be changing inom time to time, these chan ges mill be denoted on nepont. T.G. West UCC 003178 INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION p. d. box sog4. south charleston, wv oocus SILICONES AND URETHANE INTERMEDIATES SOUTH CHARLESTON PLANT to(Nom*) rviHipn Loca&ion Arnrt Attached Distribution LUipv t.o Dels OnginoMng Oepr,. Apab Subject August 14, 1984 South Charleston Plant Winterization During the 1983 Christmas Holidays we were hit with severe winter weather that cost the plant several hundred thousand dollars. Several units Incurred less damage than others due to winterization of facilities before the cold weather. I suggest that each of you review your area of responsibility and make sure that you are adequately protected this year. This Is normally one of our "long suits" and we were caught by particularly severe weather last year. However, we do have room for Improvement in some areas and I expect you will take appropriate action for correction. You may want to talk to some of your peers that had good success last year. RGL/ph 1085Y R. G. Link UCC 003179 UCC 003180 514-686-D + +DO IT THE SAFE WAY SIGNED AREA 5 MAINTENANCE INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION P. O. BOX 8004 SOUTH CHARLESTON, W. V. 25303 SILICONES AND URETHANE INTERMEDIATES SOUTH CHARLESTON PLANT 514 TO: R. H. Stodghill D. R. Stokely DIVISION: AREA: Silicones II COPY: S. J, Chanley J. R. Dean T. G. Swanson DATE: August 10, 1984 ORIGINATING DEPT: AREA: 5 SUBJECT: Winter Preparations for Silicones II In an effort to minimize the potential for freeze-ups and additional other problems associated with winter weather, the maintenance department would like to ask the Silicones II staff to prepare a list for each of the following. 1. List the equipment related repairs required. This should include items such as steam tracers, steam traps, and pipe repairs. 2. List the insulation work needed. 3. List the facility repairs required such as doors, windows, and heaters. When the lists are received by the maintenance department we will prepare a Ghant chart to indicate when the work can be expected to be complete. Please try to get the information to us as soon as possible, hopefully no later than August 24. If you have any questions or comments concerning this subject please see me. Sincerely, D. B. Howard UCC 003181 INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION SOUTH CHARLESTON PLANT , Silicones and Urethane Intermediates P.O. BOX BOD4, SOUTH CHARLESTON, WV 25303 TotNsme) Division Vmn Location Area . _ Copy to Dste &/14/84 Originating Dept ` Ares Subject Wintexization To aZJL axea 2 Opexatlont> Vep. Head*. Anea 2 needs a Wintexiaation List ion the wonk you axe expecting to need to prevent a pieeze up Like Ae had in the 83 8 84 ineeze up. We need this list by 8-24-84, so the List can be gant chanted and a wonkabZe completion date estabZished. We need 3 sepenate Lists a& ioLtows with Wonk nequests to pexionm ) the wonk. One List shouZd be ion. insutation loonk that is to pn.eve.nt ineeze up*. - . One List to covex Steam tnaps andtnacing. The othex tut should be iox window pained and doons that xequixe wonk to pnevent ineeze up&. Thanks 3.3. Ashwonth UCC 003182 4' 2-^ NEEDED t NSULATI ON WORK Bldgs 144/149 1. The leg on line to tank 1299 at number 11 swltchbank, Also a 1 1/2' section of same line above/west of number 11 switchbank. 2. Following sections of line from tank 1299 to number 22 vaporizer. A. 2' section south side number 29 still. B. 5` section at number 22 vaporizer feed preheater. C. 3' section below vaporizer acid feed motor valve. D. 2' section at "1" beam overhead switch #830 (S.E. end York) 3. The following section of number 22 vaporizer residue purge line. A. 6' section at condensate pot tie-in. B. 6' section west side tank 1283. C. 8' section over york panel board. D. 8' section over switch gear, east side of York. E. 10' section at tank 1401 tie-in. 3' section of tank 1703 acid line to number 13 swicthbank, south of tank 1366. 5. 1401 pumpout line to "I" beam, S.W. tank 1314, 8' section at "I" beam, also same line west side of number 29 still. 6. Tank 1315 pumpout line. A. 8' section south of number 29 still. B. 6' section downstream of cock valves south of number 29 still {at reducing station). 7. Tank car unloading line at pump suction, number 13 tank car spot. 8. Install the existing insulating blanket on number 1 evap. head on number 28 still. 9. Install the existing insulating blanket on number 23 kettle steam chests. 10. 3 1/2' section of tank 1270 pump discharge (to tank 1271). 11. Tank 1270 suction line. 12. Tank 1271 pump suction and discharge lines. 13- Tank 1271 circ. line at N.E. side of tank. 14. Feed line to number 24 vaporizer from tank 1271 (at feed orifice). 15* Number 24 furnace make line S.E. of tank 1271. 16. Drain legs on chiller trains at condensate pot. 17. Suction and discharge lines, number 29 still decanter B.L. pump. UCC 003183 NEEDED INSULATION WORK Bldgs 144/149 Page 2 18. Tank 1314 circulating/feed line to number 23 still. 19. Suction/discharge lines tank 1401 pump. 20. Line to S.W. side of tank 1293* 21. 1004 line at flange, west of number 11 switchbank. 22. Tank 1261 suction line (south side) (Note: Steam trap needs replacing). 23- Number 22 decanter suction/discharge lines. 24. Line to tank 1405 pump header, west of tank 1412. 25. Feed line to south end number 21 kettle. 26. Transfer line to tank 1366. 27. Suction line from tank 1368, 1369, 1367, 1365 also section of pump suction line. 28. Number 21 still decanter lines (on roof). 29. Number 29 still side make line to tank 1315* 30. Acetic acid line suction to tank 1703 pump and valve on N.E. side of tank. 31. Insulate 1001 line number 14 to number 12 switchban^ (Note: Line to be tranced first). 32. Water outlet York gear box cooler. 33. Number 21 still make line (short section next to window) 149-2 and down to number 13 switchbank. 34. Number 21 kettle pump out line. Additional work may be added to list as job progresses. UCC 003184 NEEDED INSULATION WORK Bldg, 135 Water line from 2309. Insulate steam line to number 3 still feed preheater. Insulate discharge line from number kettle pump to cooler. Insulate outlet steam from number 2 kettle condensate line. Line to tank 1203 at number 10 switchbank. lasulate lines to converter wash line. Insulate from converter wash line. Steam from number 3 still feed preheater. Insulate water bottom layer line from decanter to number 10 switchbank. New covering over number 2 kettle insulation. UCC 003185 NEEDED INSULATION WORK East side Evaporators water lines. Bldg. 17*1 ' Steam line to DMV 1 2 evaporator. Boiler feed water line to pump seal flushs. 6238 make line (top) 6237-36 make line (top) 6236 suction 6223 suction 6236-37 P. 0. line from make pump. Finish number **3 line. Finish 6210 make line, water line to 62*tO - 6250. West side. Water to 6210 jets. Boiler feed water line to pump seal flushes, also line at end of 6210. Charge line to 6210 finsih from 6206 6201 calandria. UCC 003186 NEEDED INSULATION WORK Bldgs. 133 & 134 Bldg 133 west side yard. 1. Repair the insulation on the oil lines to and from the merrill oil pumps. Bldg. 133 inside 1. Repair the insulation on the inlet and outlet merrill oil lines to Number 5 furnace. Bldg 133 south side 1. Repair the insulation on the steam line to number 5 furnace. Bldg. 133 east yard 1. Repair the insulation on the stam line to and steam condensate line from tank 1197. 2. Repair the insulation on the steam line on the north side of tank 1197. 3. Repair the insulation on the oil line on the north side of tank 11974. Repair the insulation on the air pot on the east side of tank 11975. Repair the insulation on the water line from the 2309 pump. .6 Repair the insulation on the steam condensate pot and lines. Building 134 west yard 1st level . 1. Repair the insulation on the steam line to number 15 still feed preheater. .2 Repair the insulation on the feed lines to number 11 and 12 converters. 3. Repair the insulation on the feed valves on the bottom of number 11 and 12 converters. 4. Insulate the water lines to the vent drums on number 11 and 12 converters. 5. Repair the insulation on the oil lines from number 11 and 12 converters. .6 Insulate the oil lines in the pipe rack in the west yard. 7. Repair the insulation on the 1224 pump header. .8 Repair the insulation on the steam line to number 11 kettle. 9. Repair the insulation on the steam line to number 4 swtichbank. .10 Insulate the water line to number 4 switchbank. UCC 003187 NEEDED INSULATION WORK Bldgs 133 & 13^ Page 2 Building 13** 2nd level west side 1. Repair the insulation on the steam line to the converters. Building 13** 3rd level west side 1. Repair the insulation on top of number 11 converter. 2. Repair the insulation on the oil lines from number 11 and 12converters. 3. Insulate the make valve on top of number 12 converter. 4. Insulate the steam line to number 12 converter. 5. Repair the insulation on the oil line from the surge tank to the system. 6. Repair the insulation on the make line from number 12 converter. Buidling 13*1 4th level west side 1, Repair the insulation on the merrill oil surge tank. 2. Repair the insulation on the steam line to and steam condehsate from the surge tank. . Building 134 North side 2nd level 1. Repair the insulation on the 180 pound and 30 pound steam line at the main header Building 134 South yard 1st level 1. Insulate the brine lines to the brine pumps. 2. Insulate and repair the insulation from the brine pumps to and frombldg. 13**. 3. Insulate the condensate line from the trap to the sewer from the 600pound steam line near the brine pumps. 4. Repair the insulation on the 600 pound steam line from number 5 switchbank to bulding 134. 5. Repair the insulation on the steam line at number 6 switchbank. 6* Repair the insulation on the steam line at number 5 switchbank. 7* Repair the insulation on the brine line over tank 1117, 1118, and 1120. 8. Repair the insulation on the riverwater line at number 3 switchbank. 9- Repair the insulation on the steam line at number 3 switchbank. UCC 003188 NEEDED INSULATION WORK Bldgs 133 & 134 Page 3 Building 134 1st level east yard 1. Repair the insulation on the steam line to number 2 switchbank by tank 1112 and 3 legs by number 2 switchbank. 2. Repair the insulation on the make line from the wash column to number 2 switchbank and from number 2 switchbank to tanks 1107 and 1108. 3. Repair insulation on process water line from number 2 switchbank to 2309 pump. 4. Insulate the water line from inside building 13** to the acetol reactor. 5. Repair the insulation on the steam and water lines on number 1 switchbank. 6. Repair the insulation on the steam line by tank 1101. 7. Repair the insulation on the steam condensate line from number 17, 15, & 1** stills. Building 13** 1st level inside 1. Repair the insulation on the 180 and 30 pound steam headers through the building. 2. Repair the insulation on the steam lines from the header to number 15 and 14 stills. 3. insulate the number 15 still steam chest. 4. Insulate the steam condensate line from number 15 still to header. 5. Insulate the steam trap on number 17 still. 6. Repair the insulation on the bottom head on number 17 still calandria. 7. Insulate the water leads from the river water strainer to the instrument air kickoff instrument on 2nd floor. 8. Lnpulate .the:.bottom head and pipe on number 13 still calandria. 9. Repair the insulation on the brine return line. 10. Repair the insulation on the converter feed lines. 11. Repair the insulation on the steam line and calandria on number 16 still. 12. Insulate the steam line to number 12 still calandria. 13- Insulate the steam trap and condensate line on number 12 still. 14. Insulate the condensate line from the calandria on number 16 still. 15* Insulate the steam header valve, the steam tracer lines, and header, and steam trap lines from the traps south end of building 134. UCC 003189 NEEDED INSULATION WORK Bldg 133 134 Page 4 Building 134 inside 2nd floor 1. Repair the insulation on the steam line valve and DMV to number 16 still. 2. Repair the insulation on the steam line around the valves on DMV to number 12 still. 3. Insulate the steam line and steam condensate on the heater at the south door. 4. Repair the insualtion on the steam line and the water perheater to number 12 still. 5. Repair the insulation on the 180 pound steam line to number 12 vaporizer. 6. Repair the insulation around the valves and DMV on the steam line to number 13 still 7. Repair the insulation around the valves and DMV on the steam line to number 13 still 8. Repair the insulation on the feed line to number 11 converter. 9. Repair the insulation on the brine line to the condenser. 10. Insulate the water feed and water leads on water feed to the wash column. Building 134 inside 3rd level 1. Repair the insulation on the brine line to the VME vent condensate. 2. Repair the insulation on the acetaldehyde vent conder^pr. 3. Repair the insulation on the 600 pound steam reducing DMV and line. 4. Repair the insulation on the steam line to number 17 still steam jets. 5. Repair the insulation on the steam line to number 13 still steam jets. 6. Repair the insulation on the steam line to number 12 still steam jets. Building 134 Roof 1. Repair the insulation on the instruments on number 12 still. 2. Repair the insulation on the water line to number 13 still condenser. 3. Insulate the water line to number 13 still jet condenser. 4. Repair the insulation on the steam line to number 13 still jets. 5. Repair the insulation on the steam line to number 17 still jets. 6. Insulate the water line to number 17 still jets. UCC 003190 UCC 003191 MEMO AVOID ORAL INSTRUCTIONS DATF _?-T9-<4 198 September 24, 1984 TO: D. F. Finley F. L. McCarty COPY: J. A. Ashworth D. R. Criner J. R. Dean E. A. Dumont M. D. Ginn S. Rossi Polyols Technical Staff FROM: D. H. Ott SUBJECT: Winterization Planning and Maintenance Work Just as a follow-up to our discussions last week: 1. Work scope/job lists are fairly well defined. Phase IV area is more straightforward than the Bldg. 103 area. 2. Priority of work should be done in a way to give us an : equipment system one at a time. The following basic guideline should be used. Phase IV Bldg. 103 1st SS/EB's 1 St SS/EB's 2nd Utility Supplies 2nd Utility Supplies 3rd #7 Rx, IX 3rd #3 Polymer 4th Isop Recovery 4th #1 Flex and #5 IX 5th #8 Rx, IX 5th #2 Polymer 6th #9 Rx, IX 6th #3 Flex and #1 IX 7th n Flex and #2 IX 8th Butyl Chloride 3. Insulation work appears to be a critical. Job vs. manpower must be addressed by Maintenance management. UCC 003192 2- - September 24, 1984 4. I am looking for a weekly update of progress against total planned work. This needs to be quantified well enough to be able to judge if resources will meet need. 5. Be sure that SO's are written to be able to collect up the costs associated with winterization. 6. I want to approve overtime associated with winterization preventative work. DHO/cgb D. H. Ott UCC 003193 aj CT iJs $ A *S Pofe/Z^S Z 3~~ 2c/&> {to/**# P-P P-/ /HUS S&JP /7/*<J &$<y? **t&> j*r #ot?* P pJ c*uPes /) Z ,/r ^ /3v/^ z~ fa43&x s^PSZP. /Ze&TSr/ JPsoA*s Aft-O A?^y> iy*> / Z* CcJ /*&(>*;' /?? tP' P /faC+f.5 P Pe^AA 2*2 . 222 3Z* -3 -/ ^Z/y * /1.P <? ^ /Xrtrt1 ' / / / S*T&J PZAt*.< x? xc/ dMdro*%/ ^ Z' Atrps/z UCC 003194 C P?aS** . _/ 7>rW -u^Zy f jy/ jmoZ 2>f 222 $32 /7'^ * |! p g a > w / > J `/ ^ L / $ A i l *5 <1 }^ 6I* H ii afSaj Sd< > -* jxL ^1 I JS 3 3 o NJ M. tu c4 ^ Ii V A I <2 ^ \\ 3 3 2 3 SI U. Vl su ^1 to 4 1 to J * * 3 \ * V <x >s- \ 4i* --1I a1 * -^ t mlg aut la <s V vs' ft m 'S C; rV \no-~D- Vo SVrt \r- 0" dTCr 0 n 8 od n3 $ A 5b VN.i .$ 1 fe i vi 11 MCT V Q Q K vu$ 4 8 ft V) v1 ^ -. V) ^G 5 N j <31 s to * 8b <4. 31 & K ~i ^ 5 * \*-> S 3 X "2 0Ssj V$ V'vi ^ v ii .v <3- ' .>. 13 Vl UCC 003195 i 3 a M UCC 003-196 Dui ajsS L 43 pd im z 1 2 dr Mb) 3 3 IPtf / Z --f- Off %,uthP CaHcL&F / 10 'J'VSu C/tT&e-S ffrtyb 72 /z v % /b ^lo V 63 To Do (D Mte r/fcvis f2o ^laht-r^n pezicM -4 S'f^^Y' rf hv fu^ O' '0V -fO. (TtfSt- CdO tut its f17SUC/HVCS. Cttn 'iiitif fc&nffh Gn GT msuc /fieri s Tkt^j ux>ul MT /n^UituS --^ ^hejil /k. a Gd 6 T 6$ ifA Vhtt'tl, (cei'ty fe (jjfur\ UCC 003197 4l JLjL 33 v 2-3 f4~ 2-^ j-D 4i DO IT THE SAFE WAY Hh SmED^H'6) UCC 003198 o <\i wz* >uzUJ o Uu.. ip; O W fcUzsn1|l -1 uL>zJuLl UJLi. (ri j 1: j * . *. S j *\ ["0<^c^Oc _5-- L9 O dH ; Q ~ 6 o ''Q'On <T M 1 : ; i L ! do-- rn o -- i;: 1 /j 10 cf o.V l) o o o L)L) o o o *0 --< 1 ^ 1 <d % i ^ *4 '4 ^ -O- -i-\r> - ~y <r^ -- --' ci >0 -- d- ! ! i i:! f Lu : i 1 l ! : : i A 1 J1 O'^'V-O l0 0:0, 3 o ^7 ^7 --* o d ; ; W *7<t5 d ':: :' ^o Ua : : 4; : i . o 1 j J ; 'O'*TM J 'h ; 3 t) i ! ! n !! M ! : 1 ! !` i : : M i : i ! . V) VO I -. 1 i i c8&J N U) U "2 a n ri o --o o -- d os o--: \ri~T !! || i1 I! :i | ' ; i o oi o o o1 qi ^ V* ri io 6 o ii:: ! .' - v, i ! 4 r\. ~t 6 !. V) o ^ c ;i i' :: oo , 5" 4i;1 tjO r0 ' i H 1 Ov4 e * -1 7<l o 3 ce 0i i 1J ! : ; -i lOrtO^C^CT --OCT Q \f) -J- ' d 1 o : 61 -------^' t( -j 6 . i!i:;1 :!.;; Q o O o J o <"t o \q O O dcfidrnoo . c* ^2 =r (O -- <-<-- Oo zf- ci -_ o o' : : .. oo dd h !.. L i : ; . : : : : : a R 3 a i ST a <ax ZoC r 1 d! 0) ^ ~:rn? i: idto!O'1--;-'j : ^1-C*T?---i---lOl t nfo^,*- i (O O : n? j o WO 0^.0 WJ O o q o O o i oo o ro o 1 ^ d* <? ,S5^; 2:- ......:. j _ : : i i . i ' ' i i i . i .: : ' d ^ ^ ^ ^ 00 ^ r0.`T | ^lr <*) *0 cs o -- c- io : -- : mo o \! i : ; : ; ; ' ;' i1 : , 1 : i * ; , i . : . ' ttCc j^ ;j W 4 : *o n<7: ? K-, WO < ^- It O lQ Vr? :o ~q l i * \5 tfl < i U < 3 X It ! ! ! :3! i! iO ff) :^ 6J J0i^rlo0^Ot^Of^f) !--9:m cO, d --- d |:j: Sii.; 9 ^ oo; O O : t0 *0 4" qj r-+ ftrt |-1 % oa" t *i n5 O `d O. ft? O ^ ! O --9 (Q % 19 ^ . Oo "tf w:1;" | cr id| m 6 n o 43 m -3" ?j 1* 0" "0 ; ;oO :"^'-7-r__(--_y-3d vf)T o& *0 !o _ ~ doo'd --. 6 qo 0 M M ! j ; ; ! :....... :..; yj ^iVjI' OOO OOl--d QO! qoo o ^ -z 2 -g ** i : i \A r P&O Q d >0 0 J 3t ^ i "1 r6 H = - d r !1 ' i "Z <n ` !^ .i -- nfi fi -9 -- ^ . ', H * s a 22 s: 5 s; a s s ss " ;1 1 !. '1 ; :: ;3. jd oo 5 ssa :: ** s * a 0) A o000O00-0--- -------~ -- J- UCC 003199 4 *`<0 53 "2^,C& 0ov* ' * .O M w ** *'-** ft ^)oOQ QQOOOo^1 ^0 5 *3 "* <H >- **> v >* > goo-OSv'^*>*. W 0 O O fi o ^ ~ ' ' "' < vjs ^ dO 6 O '^'; '"-CVN$(V),SwCY Q V> [Y l<| '>.'s- O JS jftuc o" di d' <$ o d. c> ^ o- o'ooo'd^Q 31 <5 o ^ ^ ^^ ^ ^^f*t<fl_i ^ --- o O_ C'-'"5 O OO CN.r^v>av^'0^i 4 * 4 ^ A jt ^ A yi/>i 'A /% m v\ ^ LA t ^ s ff C ^ op 00 ^ y, v > \3 -'3 <T \3 a3 v3 & 5 ''S \5 v3 \ ^ <3 o cf c[ Q O Sf Q oppo o 0 o oo o q > c W0 <t 3 r-Qt. v** ,1C2^l Nil . v* /\ /v r*\ *33 ^ h. '; CV X> ,vCfc n*. Ctl <4 - ^ ^ o < 'I h M 'o ^ n't Q *1 ^ CiO D00o,<3^0^^ <S6^^ s. *>c v* H ^ '^'v f^ s*'^ v-ooi cr"^ o ^ g Q ^ rti -- -- C* O S ~i d ^ d -4 - ^ o'w W <t v- v. s. ^ ^_- v- t- 1; t-i . v-: ' ** t* *, , 44J4 3ij4JiiSj.5i.3H N <* I 3-gJf a 3S J4J-S-3 JU i^b'Z-o^Szo eo "2 or d d^?> 3 o!s?oo!o0: o C* >* ~<x3. . " i 1 . J j -- (VUIJLV W W5 j r / t p J*- o* i ( -z OOj i * s, Jt * ft. * * ^< Iti 5 Vj>- d*>0icv ss| nI o!i'vi ^.^viOt vtf ^>o dec 5 ^ ogj dd| njeSO 'S'd Hj *4 oi ^ 4 r* >. ''ft rm ai r 1 8^i?II?|?IS'5 r* ''as10 V gi ia ilyf Jaos5c*?*5J1^ o >; rv ^ Or ^ s> Or ----o vd r< -H rv* tfv' rt* * - . ^ . _* ... x ^ '; i: ' ! k OOvS OC-O ^c\r^sjTV''Ons <3 nio o>h ^ o n^ o o f$<5^o CQ -/ 71 i i V ' ^ 1 " ; -'. m; io ^ -- : V !! oi WnJ ^ 'tjn K^| ^ Vo jo; io; ; ,Q& 00 ri-^k' !f\ vO Ui >t; j>% 'l^r^ !> 1^: ,, 'J m j "j I I '| i r iU|y.i^o,^^uoi9' &Aw SS Nv S*1"*] i ; !" i , ! O* !7 !i ii U * a *; *i *. > | *-*'*-;*' isP i x5 noriv-^NsC* w * * * u cv >>: 2 fi <~") 3S^!^oo!S2 2^c;=ol,q* 3-- 2g>?>[* i C* ; j ^ x> > f? tr> < \r UCC 003201 INTERNAL \ CORRESPONDENCE BUSINESS CONFIDENTIAL UNION CARBIDE CORPORATION r. a. box boo4, south charleston, wv 35303 SILICONES AND URETHANE INTERMEDIATES SOUTH CHARLESTON PLANT To (Name) Division Location Af'oa Mr. L. W. Phair Mr. R. P. Fulknier Mr, W. A. Garrett Data October 23, 1980 Originating Dept- RECEIVED n *r* - IS80 Si jUfCinc RP^^ - Project Insulation Crew * s " " ?'iKnier The work of the Project Insulation Crew on the plant's main steam headers will be completed within the next 2-3 weeks. We need to set direction for future utilization of these people. Experience at other UCC locations, discussions with you and members of the Maintenance Management Team, plus input from Operating Department Heads and C. E. Fry, all suggest that we should consider retention of this insulation crew to upgrade insulation within our operating units. This conclusion is supported strongly by members of the present crew. All respondents feel that the plant's present insulation needs can most effectively be addressed by a combina tion of project crew and our regular area insulators. The project crew is to concentrate on preplanned "blocks" of upgrading, with the area insulators attend ing to miscellaneous insulation work associated with day-to-day unit repairs or alterations. We propose to form a standing Project Insulation Crew of 10 people, plus its own supervisor. Past efforts to effectively use such a crew under the direction of the insulator supervisor in the particular area where work was being carried out have not proved to be successful on a continuing basis. They did not receive sufficient supervisory attention, and there was a tendency for their efforts to be dissipated on day-to-day miscellaneous stripping and repair work. The proposed crew would be used solely for upgrading work, planned in advance in conjunction with the operating department receiving the service. The Area Maintenance organization would neither borrow crew personnel, nor be associ ated with their supervision. To help assure this separation, it is proposed that the crew's second-level of supervision be provided by E. 0. (Dick) Harrah, whose qualifications include a past assignment as head of our old Area 6. We are now in the process of identifying "blocks" of insulation upgrading work within each operating department in the plant. A block of such work is roughly defined as any combination of line, vessel, or equipment insulation within a department that meets the following criteria: 1) A minimum of one week and a maximum of 2-3 weeks of work for the proposed crew, and 2) Is con fined to a small enough geographical area of the particular unit to permit effective hour-to-hour supervision. The concensus is that scattered work, or longer intervals of concentration, would promote lower productivity. UCC 003202 Mr. L. W. Phair -2- October 23, 1980 When identified, blocks of upgrading work would be scheduled on a plant-wide priority basis, considering input from both the involved departments and C. E. Fry. Prior U/A would be secured with the owning Department Head as to the scope of each block, the duration of work, and the probable cost. Re quired materials for each job would be on site before work started, and would be secured before the preceding job was completed. Progress reports on each block of work would be prepared as the job moved toward completion to assure that commitments were met, or deviations were understood and accepted. Crewrelated costs will be assigned to a new account, 327440, so they can be separated from area insulation work both on a departmental and a plant-wide basis. The present steam-line crew would serve as the nucleus for formation of the new crew, with some limited personnel changes. Such changes would provide an appropriate craftsman-apprentice balance, and assure that all members of the new crew were assigned at their election. Future crew assignments would be made as necessary to maintain these conditions, where possible. We suggest that the new crew be housed in Bldg. 428, using existing crew facilities, and that we continue our present practice of providing transportation to the current job site. ` If this approach to plant insulation receives your endorsement, we would intend to sustain it as long as meaningful crew-type work was available, and our clients agreed that the approach was cost-effective. A failure to meet either of these necessary conditions would initiate an immediate review of our approach, to alter or eliminate the special crew. As expressed earlier, there is a broad concensus in support of this proposal. Your endorsement, and that of the other managers is solicited. Also solicited is approval to recognize the contributions of the present crew's up graded supervisor, Mr. W. 8. (Bill) Spurlock. We reconmend that he be promoted to Maintenance Supervisor and be assigned responsibility for the new crew, reporting to Dick Harrah. He has demonstrated an ability to get the work done, not only on the steam headers but on the recent EO line repair job which called for the insulation of 2500 feet of 2-inch line on a crash basis. He has the support of the present crew, as well as the Maintenance Management Team. We have reviewed the potential to promote a female, minority, or younger craftsman, and conclude that this opening does not represent a viable opportunity for such a promotion. This promotion will not detract from our ability to meet the 1981 exempt head count limit in Maintenance. Please advise as to how we should proceed. JSC:mb UCC 003203 Profo-Bag I CUSTODIAL/MAINTENANCE WORKERS' ASBESTOS SAFETY BAG Asbestos-covered pipes pose serious potential problems for the owners and operators of private buildings and industrial facilities. Contamina tion can be released into the air by deterioration as well as by removal, emergency repairs and routine main tenance work on joints, valves, fittings and hangers. Because custodial and mainte nance personnel can be particularly vulnerable to the long-term effects of this contamination, government authorities now require strict pro cedures for all asbestos-related work. The Profo-Bag- is a portable, sealed workspace which holds in air borne contamination created by work on a pipe. Properly used, the ProfoBag- can reduce the exposures of your personnel at the same time it reduces the costs associated with such work. For instance, federal as bestos guidelines require that a building space be enveloped, or "contained," in an airtight seal of polyethylene before work begins. Profo-Bag offers quick, efficient method for performing work or, and around asbestos-covered pipes. ~ However, by using a Profo-Bag' for work on small runs of pipe, the need for costly containment tents and decontamination chambers is eliminated. In 1983, the U.S. Environmental Protection Agency completed its analysis of the new Profo-Bag, or "glove bag," technique and recom mended its use in the new federal asbestos guideiines. At the same time, in its recent feasibility study, the U.S. Navy reported Profo-Bag technology to be "a workable solu tion" which takes "about one-fifth the man-hours required for a standard containment tent." The 7-mil, 50" X 64" Profo-Bag is a sealed work space accessible by poly-coated Tyvek sleeves. This sleeve coating prevents microscopic contamination from escaping through the porous Tyvek fabric. Sleeves are heat-sealed to the main body of the bag to guarantee the maximum in air-tightness and seam strength. When full, the bag serves as its own asbestos disposal container, complete with required warnings. ACTI also offers a worker's manual and video tape explaining exactly how to plan and execute a Profo-Bagproject. Asbestos Control Technology, Inc. P.O. Box 183, Maple Shade. NJ 08052 / 1 -SOO-221 -1911 / 609-235-1190 UCC 003204 /?5&ES TO5 HANDLING Dp / jr lCC U->,yf ~ X XT' 74 /'A*4r`.-'tA y//r / ' /< C J& X /-/&&.' .J 'c / /V -J i'*z. - -Jeiac.i X. ' ` * tScftJ'i * ' - J L y , 'J<r>a/. DTstJ^cf. 02^ XXrl- S/ 2{X Xj ' fi&TtffiPLT-r-t^ ^yr&d/c&Ty&iO sLiXitdc o-X-LjX'-L . ^/c<-j-A<:X s/ji&h i / , <fU' JiCtyj _ 2ASt i, utyaNJi,- yL/l&O- ,Xsl // XT' ALiS&td'' CcC-Ccf- t>~t-y(4. Ut rl X Xz i'eTD . pXi.t/ . zy<Uy yuy-yf ^tL<r-c4DC *//? ^Xkrffc-4- -^Ljyac- -6ea*U6*-e XX~aXst X-t&py.CiiXcct -<Xf XX Cti- j-Xn ir, ) ^A-yi-'^C ,-\f.y>. -/>/ j/c7i-t> S//<ri Si-^T'-X, T y> i-fi / /-&t'LsyXX?s<X., X _ , r . p/Xs,: XX t-lcv p}`Jt / - s$ - X2'i - Z9cx X. c c/ j'/alf XTiPZ XlDty'L s',, {S^djdCC^tiA `y/j '}ZNyC!iL 1- , XU &n-iaz*? yX<fXXte&i, Xa, dfi3'*yjf'iDd^T 7, <?,jy"{/7t, ,. 0 / {/ -JjXaN* '/. yyt>X/i //cyX-' c.tjL X.C -Tr~-i XCH-i-u Vi17/ 7 '/ / *' i. _ jly J/Ji #/-> > -, > is. i yy^'yr a & isi NT .yXrocX - / - toscsT -tAX. sUnTLA-t c ^ cX .LNlXccX(,- JLC/uiA'f/, sd'*riari&~- A*i*s&tiS<sr 4/ " 1 7/ f / y/ - / i>0{yUCD . tyy'T ^t.Q s<L^ Lcts-ity?, t)U- 4yr>> ic- e>f XAtf/l/ . yttu* *u.yiA^ :' ' ^ -. ' z^'i^yicX' Xyesri.-'4`-'T- >sy ?fAc- CTi/iiC 76T- H96T 'DA&Au'tC -t Z(i^iL- ?X .dues"'' /. / , Xj't /; /? JNN, If / i X 'L. f. 'i ^iio' -Co l 6 Lc-r, t t ( '.y./. , .y. , X/'- 'y -JisijyC .Xcy >; <7 X////_<__,;jy^.^cz-c' 74>$X X-uXff/ly 77/ 7 --- / Cz-t-t , ( ,/ -JU-, 7TH-H6XS t **rzSiJLe.X //./-- )<nxyi4i /n(A; - f.-ti7sT'tsrAyT-s;.-'? 4 i 7/ //L'T ,--v >! 1^41.77 7 ft / . /Ay J-'-'St/zr /7-C. yj.j.^7 ../,. <y.'.y , ' '' ac/l^6 -7//X)'/ TL&TX'Xt <:. y . X > ______ " j.> i, C-Xf/ yic-yf/ // y.ct.z//641, ^ rz%7y. r -s, /*, / slG'UZ'Ct , UCC 003205 '/*&/Si --' &its'* 'C * 'St's //ei*ry\i} . -- --J-C'/'U' 7 * -47 u i c * v" a. '- yT zb l-Z . yi/yi^jy'ly y. \J?-C-^l Cs C-eS O 77^ ^ * ~y^ -:. -- ........-- ..................... ............ /yy ~y~. ^ s_* <-j.- ^y^-s -szy&y., j _, yy/.^yy '&. ,*. ^p/j t jy~ UCC 003206 MANUFACTURING COMPANY, INC. P.O.Box 371 Do Pare, Wisconsin 54115 (414) 432-7574 Good Day! Enclosed please find a catalogue sheet describing the "Collector" asbestos removal chamber. If you are looking for a quality glove bag, you need look no further. We have 12 different sizes and styles, including a verticle bag, at very competitive prices. For more information, please contact me. Thank you. Argil D. White President Ship To: 1121 McDonald Street, Green Bay, Wl 54303 UCC 003207 -REN'OAL CH/Y1/IBER COLLECTOR! The Safe, Effective Asbestos or other Contaminant Removal chamber from Arg-Dri ALLOWS WORK IN A TOTALLY CONTROLLED ENVIRONMENT. Using the Arg-Dri asbestos pipe removal cham ber is an extremely effective procedure designed exclusively to protect the worker and to prevent asbestos fibers from escaping into the atmo sphere. Arg-Dri is easy to use and available in a variety of models, made of 6 mil. high quality, durable polyethylene, excellent internal visibility. 3 mil also available - see specs. HORIZONTAL PIPE VERTICAL PIPE EVEN GREATER FLEXIBILITY AND COMFORT. EASY TO USE - 5 SAFE, EFFICIENT STEPS AH Information. tecommendattons and suggestions appearing herein concerning Itwu products on bawd upon fools and data believed to be reliable. However. If Is me user's responsIbllHY to determine me solely, toslcfly and sultobHlty tor his own use of me product described herein. Since me actual use by omen Is beyond our control, no guarantee, expressed or Implied. Is made by J. V Manufacturing Company. Inc., os to me effects of such use. the results to be obtained or me safety and toiletry at me product nor does J. V. Monulocrurtng Company, me., assume any liability arising out of use by others of Ihe product referred to herein. Mor is the Irtomumon herein to be construed as absolutely complete since additional Information may be necessary or desirable when particular or eiceptlonal conditions or circumstances eiist or because of applicable laws or government regulations. Homing herein contained Is to be construed as permission or os a rscommendatlan to tnlnnge any potent. For Additional Information Contact J. V. Manufacturing Co., Jnc. 1121 McDonald Street. Green Bay, Wl 54303.414-432-7574 UCC 003208 The tools you will use should be put Into the Inside pouch before ' closing the bag around the pipe. Place the chamber around the pipe, bring the open edges together and seal with tape. Grommets are placed in center of bag for added support by tying rope to the pipe from the grommet. In an area, away from the work area, silt an opening only large enough to hold the vacuum hose. Through this opening, with a portable sprayer, spray the area to be worked on until It is wet. To perform the task, insert your hands and arms into the chamber. With the necessary equipment (already In the bag) remove the asbestos from the work area and gently collect the debris in the bottom of the bag. After the Job has been completed, place the tools in the pouch, seal the debris in the bottom, vacuum the top area and remove bag lor disposal. SPECIFICATIONS FOR ARG-DRI ASBESTOS PIPE REMOVAL CHAMBERS -- j Product Product Code Description 600203 Horizontal 3 mil, 36"W x 60"L, Printed, Tool Holder, Embossed 28" Poly Sleeve & Glove 600206 6 mil, 36"W x 60"L, Printed, Tool Holder, Embossed 28" Poly Sleeve & Glove 600306 6 mil, 60"W x 72"L, Printed, Tool Holder, Embossed 28" Poly Sleeve & Glove 600406 Vertical 6 mil, 60"W x 72"L, Printed, Tool Holder, Embossed 28" Poly Sleeve & Glove 600213 Horizontal 3 mil, 36"W x 60"L, Printed, Tool Holder, Embossed 28" Poly Sleeve w/cotton flocked lined rubber glove 600216 6 mil, 36"W x 60"L, Printed, Tool Holder, Embossed 28" Poly Sleeve w/cotton flocked lined rubber glove 600316 6mil,60"Wx72"L, Printed, Tool Holder, Embossed 28* Poly Sleeve w/cotton flocked lined rubber glove 600416 Vertical 6 mil, 60"W x 72*L, Printed, Tool Holder, Embossed 28" Poly Sleeve w/cotton flocked lined rubber glove 600506 Horizontal 6 mil, 44"W x 60"L, Printed, Tool Holder, Embossed 28" Polv Sleeve & Glove 600516 Horizontal 6 mil, 44"W x 60"L, Printed, Tool Holder, Embossed 28" Poly Sleeve w/cotton flock-lined rubber glove ' 600606 6 mil, 60"W x 60"L, Printed, Tool Holder, Embossed 28" Poly Sleeve & Glove 600616 6 mil, 60"W x 60"L, Printed, Tool Holder, Embossed 28" Poly Sleeve w/cotton flock-lined rubber glove Arg-Drl* DISPOSAL BAG (BURIAL) 600103 3 mil. Printed, 36" x 60" 600106 6 mil. Printed, 36" x 60" 600806 6 mil. Printed, 60" x 72" 600706 6 mil. Printed, 44" x 60" 600906 6 mil. Printed, 60* x 60" Packed Per Cose 12 12 12 12 Industrial Cost Per Case 1-4 5-9 10-19 20 + Cases Cases Cases Cases 12 12 12 12 12 12 12 12 100 50 35 75 72 For Additional information Contact J. V. Manufacturing Co., Inc. 1121 McDonald Street. Green Bay, Wl 54303* 414-432-7574 UCC 003209 UNION CARBIDE CORPORATION SOUTH CHARLESTON PLANT Safety and Health Department South Charieston. West Virginia 25303 J. K. Corrie p. R. Doug! as w. D. Howard c. E. Pries tl ey J. R. Roy T. G* Swanson J * R. Dement D. A. Gossel in C. H. Hancock C. R. Rotthoff M. J. Shoger E. D. Southard DATE: September 25, 1986 SUBJECT: New Asbestos Construction Standard Attached for your information is a summary of the Asbestos Construction Industry Standard. This standard establishes a permissible exposure level of 0.2 fibers per cubic centimeter which represents an order of magnitude reduction in comparison with the prior limit of 2 fibers per cubic centimeter. If you have any questions, please contact me at your convenience. WJV/yc 1692A Attachment UCC 003210 SUMMARY OF THE CONSTRUCTION STANDARD The construction standard has nine (9) appendices. Appendices A, C, D, and E are mandatory. The other five (5) B, F, G, H, and J, are non-mandatory. KEY POINTS P. E. L. (Permissible Exposure Limit) = 0. 2 - Fibers per cubic centimeter of air determined as an 8-hour time - weighted average airborne concentration. Triggers restricted areas, respiratory protection, protective clothing, and other requirement. fction Level = 0.1 f/cc as an 8-hour TWA. Triggers exposure monitoring, worker training, medical monitoring. No Ceiling Limit Separate Standards - Apply to general industry and to construction, because of differences in work forces and work sites. (Industry's fixed site manufacturing workplace, long term employees versus construction's short-term projects, temporary work sites, highly mobile work force, and unique characteristics of some operations.) Both standards provide requirements for methods of compliance, personal protective equipment, employee monitoring, medical surveillance, communication of hazards to employees, regulated areas, housekeeping procedures, and record keeping. UCC 003211 2- - Scope and Application of the Construction Standard The construction standard is geared to apply increasingly stringent requirements to the highest potential exposures. Six key construction activities that are associated with asbestos are listed; demol ition/salvage; removal/encapsulation; construction/al teration/repair/maintenance/renovating; installation; spill/emergency cleanup, and transportation/disposal/containment on site. Startup Dates For the construction standard, (effective July 21 , 1986) all requirements must be complied no later than January 16, 1987. Comnunication Among Employees This requirement provides for the safety and health of other workers on mul ti -employer work sites. Construction employees directly involved in asbestos related activities must inform other employers working nearby of the existence of asbestos, hazard levels, regulated areas, and rules. Exposure Monitoring The new asbestos standards cover specific provisions for monitoring, including methods, frequency, initial monitoring, and employee notification, because of the differences in work sites, the general industry and the construction standards differ in some monitoring practices (i.e. frequency). However required monitoring methods and equipment for sampling are identical. The construction standard calls for daily monitoring of employees unless all employees are equipped with positive pressure supplied air respirators. The standard also allows for discontinuation of monitoring if employee exposures can be statistically shown to be below the action level (0.1 f/cc). In addition, the standard does require initial monitoring to determine the effectiveness of engineering controls. UCC 003212 -3Respiratory Protection The standard stipulates rules for respirator selection, program of proper use, and facepiece fit. The standard stipulates that the employer must provide respirators appropriate for an employee exposure. To help assure that respirators provide employee with the necessary protection, the standard requires employers to periodically perform either qualitative (QLFT) or quantitative (QNFT) fit test on all users of half mask negative pressure respirators. If negative pressures are used, high efficiency filters are mandatory. Protective Clothing and Equipment The new standard stipulates that protective clothing is to be supplied to all employees exposed above the PEL of 0.2 flee {a regulated area). An additional stipulation in the construction standard is that a "competent person" at the asbestos removal demolition site must periodically examine clothing {worn by employees within negative pressure enclosures) for rips and tears, and mend/replace that clothing. A competent person is defined as an authority on site who identifies existing asbestos hazards and has authority to reduce/eliminate them, is trained formally in all aspects of abatement and removal procedures, supervises employee monitoring, personal protection, and understands and carries out provisions of the standard. UCC 003213