Document EqvRw2qLNDwq62kRoKvxnnzaj
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY
REGION III Four Penn Center - 1600 John F Kennedy Blvd
Philadelphia, Pennsylvania 19103-2852
Report Title: Inspection Date(s): Regulatory Program(s):
Geospatial Measurement of Air Pollution of PES Former Refinery 3/28/2023 SIP, Title V, NESHAP, NSPS
Company Name: Facility Name: Facility Location:
Latitude: County/Parish:
Hilco Global PES Former Refinery 3144 W Passyunk Ave Philadelphia, PA 19145 39.9147 Philadelphia
Longitude: -75.2005
AFS Number: Permit Number: NAICS Code: Unique Project #:
110000336994 OP20-000052 324110, 424710 3E23CA087A
SIC: 2911, 5171
Facility Representatives: Pat Kelly Phone: 215-339-7277 George R. Toth Phone: 215-339-7477
Contact: Contact:
pkelly@hilcoglobal.com GToth@hilcoglobal.com
Point of Contact
EPA Inspectors:
Paul Arnold
Phone: 215-814-2194 Contact:
Arnold.Paul@epa.gov
Parmatma Adhikari
Phone: 215-814-2161 Contact:
Adhikari.Parmatma@epa.gov
Scott Yanos
Phone: 215-814-2128
Contact: Yanos.Scott@epa.gov
Alex Everhart
Phone: 919-814-2114
Contact: Everhart.Alex@epa.gov
Nicholas Bobbs
Phone: 202-564-0726
Contact: Bobbs.nicholas@epa.gov
Philip Myers
Phone: 303-877-0561
Contact: Myers.philip@epa.gov
PAUL EPA Lead Inspector ARNOLD
Digitally signed by PAUL ARNOLD Date: 2023.05.18 07:13:00 -04'00'
Signature
Paul Arnold
Four Penn Center - 1600 John F Kennedy Blvd
(3ED21)
Philadelphia, PA 19103-2852
KRISTEN
Digitally signed by KRISTEN HALL
Supervisor HALL
Date: 2023.05.18 07:18:36 -04'00'
Signature
Kristen Hall
Date Date
Table of Contents
Section
Page
I Introduction............................................................................ 3 A Summary of the Facility.................................................................................. 3 B Inspection Opening Conference...................................................................... 3
II Site Activity/Process Information.................................................................... 4
III Observations.................................................................................................... 4
IV Closing Conference......................................................................................... 4
Unique Project #: 3E23CA087A
Page 2 of 4
I. Introduction
The United States Environmental Protection Agency (EPA) conducted a Geospatial Measurement of Air Pollution (GMAP) monitoring at PES Former Refinery (PES, Hilco or Facility) to determine if elevated levels of compounds were present. The Philadelphia Air Management Services (AMS) was notified of the inspection on March 20, 2023, via email. On March 28, 2023, EPA notified the Facility of the planned inspection via phone.
A. Summary of the Facility
The Facility is located at 3144 W Passyunk Ave, Philadelphia, PA 19145. The Facility was formerly the site of a large oil refinery and tank complex under Philadelphia Energy Solutions (PES), which was mostly used to refine high-quality gasoline. Following an explosion at the Facility on June 21, 2019, PES shut the Facility down and sold the property to Hilco. Hilco has been redeveloping the land in order to convert it into warehouses by removing the refinery and the storage tank systems. At the time of the inspection, only one tank was actively storing oil, which at this point was a four foot accumulation of sludge at the bottom of the tank.
The Facility received a Title V Operating Permit (OP20-000052) from AMS issued on October 7, 2022.
PES Former Refinery is classified as major source for Volatile Organic Compounds (VOC), SOx, NOx, CO, Hazardous Air Pollutants (HAP) and Particulate Matter (PM). The Facility is subject to, or potentially subject to the following federal regulations:
40 C.F.R. Part 60, Subpart Ka: Standards of Performance for Storage Vessels for Petroleum Liquids for Which Construction, Reconstruction, or Modification Commenced After May 18, 1978 and Prior to July 23, 2984
40 C.F.R. Part 60, Subpart Kb: Standards of Performance for Volatile Organic Liquid Storage Vessels (including Petroleum Liquid Storage Vessels) For Which Construction, Reconstruction or Modification Commenced After July 23, 1984
40 C.F.R. Part 60, Subpart IIII: Standards of Performance for Stationary Compression Ignition Internal Combustion Engines
40 C.F.R. Part 63 Subpart R: National Emission Standards for Gasoline Distribution Facilities (Bulk Gasoline Terminals and Pipeline Breakout Stations)
40 C.F.R. Part 63, Subpart ZZZZ: National Emission Standards of Hazardous Air Pollutants for Stationary Reciprocating Internal Combustion Engines
B. Inspection Opening Conference
At 02:54pm on March 28, 2023, EPA inspectors arrived at the Facility for a CAA Inspection and conducted a brief opening conference. Hilco was represented by Pat Kelly, Director of Utilities and George Toth, Vice President of Refinery Operations. EPA inspectors, Paul Arnold, Partmatma Adhikari, Nicholas Bobbs, Phil Meyers, Scott Yanos and Alex Everhart, presented
Unique Project #: 3E23CA087A
Page 3 of 4
their credentials and explained the purpose of the visit was to conduct a Geospatial Measurement of Air Pollution (GMAP) monitoring. EPA inspector Nichola Bobbs explained that the GMAP vehicle has the capability to monitor Hydrogen Sulfide (H2S), Volatile Organic Compounds (VOCs), Methane (CH4), Sulfur Dioxide (SO2) and Benzene (C6H6).
II. Site Activity/Process Description
The site activity mostly has to do with the removal of the refinery and tank farm. Most of the site has been cleared from the former refinery and tank farm with only one active tank, Tank 273. This tank is still active at the site and, as described above, only has four feet of oily sludge within the tank, according to Pat Kelly. There are pipes that connect the facility to the tank farm across the river but they have been decommissioned and cleared of any material then filled to prevent their use, according to Pat Kelly.
The opening conference concluded at 03:06pm.
III. Observations
EPA inspectors were led on a drive through of the Facility at 03:09pm by Pat Kelly of Hilco.
The first area observed was Tank 273. No significant readings were recorded by the GMAP at this location. After this, the GMAP was driven to the area where the benzene tanks were located before they were removed. No elevated readings were observed by the GMAP at this location. A designation of "elevated" means elevated concentrations of the listed pollutants the GMAP monitors were above the background level using the GMAP. Actual numeric concentration readings observed during the monitoring event were not yet verified at the time of this report, but can be shared with the Facility, once the data becomes verified.
The drive through concluded at 03:38pm
IV. Closing Conference
After the tour of the facility, EPA inspectors, and Pat Kelly had a brief closing conference to ask additional questions and discuss observations. The EPA inspectors noted that the investigation is on-going, and any areas of concern identified in the final reports do not necessarily reflect a violation or deviation, rather, they are areas that will require further investigation. EPA also noted that they would issue an inspection report within in 60 days, with a copy to the State. Simultaneously, EPA will perform a detailed review of records and may have additional questions.
The inspection concluded at 03:45pm
Unique Project #: 3E23CA087A
Page 4 of 4