Document Eqrvw95NkE7ZGR6KX2yjeab30

",rOKHO"W. M. Mees W. J. Litschgi j. P. Mieure * k GG R ESS REPORT ORGANIC CHEMICALS pIVISION * 1ECHNOLOGV DEPARTMENT 0. Hicks E. S. Tucker FOR January 1972 F- T A i L * YES '1-- i~i ll NE r MO 6*' C 5 1-31-72 A tL OC T ON St. Louis - South Second Street NOS 2-21-760.01-13480, 85010, 16300 Thit document it tht fwoperty ol MONSANTO COMPANY li conttint CONFIDENTIAL INFORMATION which mutt not be reptoduced, itvootari fo uneulhonztd person* or enr ouind* thfl Company school proper aurhonttfion. The recipient it tetpontibi* for its tefeVeepmg and das truciion. , D IS T R (BUT ION 'WITH OE T AILS H. S. Bergen M. W. Farrar *P. B. Hodges W. K. Johnson *R. E. Keller ^*R, H. Munch *W. B. Papageorge T. M. Patrick *W. R. Richard *C. W. ROOS J. E. Springgate *E. S. Tucker/W. M, Mees/W, J. Litschgi *E. P. Wheeler/G, J. Levinskas PUOJC ct T IT*, e. ENVIRONMENTAL ANALYTICAL STUDIES - RESEARCH AND DEVELOPMENT, MANUFACTURING AND OUTSIDE SUPPORT STUDIES IOJCCT OHJeCTfVC Identify, locate and assess the magnitude of Aroclor pollution problems, help determine what needs to be done to control pollution sources, verify the effectiveness of proposed pollution control procedures, guide develop ment of recycle and/or disposal methods, and provide collaborative data for legal and regulatory purposes. SUMMARY During the period covered by this report (January 1972) , M8 environmental and research samples have been analyzed for polychlorinated biphenyls (PCB's) by electron capture gas chromatography (EC/GC). Analysis of these samples represents a minimum manpower expenditure of ^168 hours. v A table showing the sample sources, types, and the level and Aroclor found as well as the support objective is presented in the details section. PCB's typical of our Aroclor products have been found at levels above and below recommended guidelines in: . General Electric, Frigidaire, and Buick plant waste water effluents.. . J. F. Queeny plant sewer effluents. . General Motors Corporation hydraulic fluids. . Process water, pulp, and paperboard samples from Alton Box Board Company. . Vanillin and Vanillin Black Liquor from the Monsanto Seattle plant. . Commercial dishwasher detergents manufactured by Economics Laboratory, Inc. Additional external and internal support has been provided in the form of: . General internal and external analytical consultation. . Distribution of Aroclor methodology and reference standards. . Determination of the soil migration characteristics of Aroclor 1016. . Discussion of the PCB environmental problem with representatives of the "academic" community and. the Office of Science and Technology. . HONS 2069S3 2-21-760.01-13480, 85010, 16300 1 Page No. 2 FUTURE PLANS PCB Analysis 1. Seven grab samples from J. F. Queeny sewers. 2. Two J. F. Queeny monthly sewer effluent composite samples. 3. Ten PCB fortified water samples fcr General Electric, Pittsfield, Massachusetts/Monsanto intra-laboratory methodology check. 4. Twenty-three fortified water samples for inter-laboratory (A/s, WGK, Anniston)methodology check. . 5. Four paper samples from Champion Paper Company. 6. Complete Aroclor 1016 soil migration study. 7. Analysis of Kanechlor 400 for furans. 8. Three clove oil samples from Monsanto Flavor/Essence, Inc. H. J. Litschgi db 2-2-72 E. S. Tucker HONS 206954 DETAILS (Cont'd) Sample Source Alton Box Board Co, Alton, Illinois CMC Frigidaire Dlv. General Electric ' Pittsfield, Mass, GM, Buick Division Flint, Michigan J. F. Queeny Monsanto Seattle 1 i Electro Sol and ' Finish Sample Matrix 2-21-7o0.01-154b0, bp'Jlu, lo^uu TABLE I Page No- 3 customer service Associated # of SarnDles Level Found Aroclor Support Objective Paperboard, water and pulp 5 ND* to PPM 1242 Pollution Control Plant Effluents 2 PPB 1242 Pollution Control Plant Effluents 5 PPB 1242 Method Check Settling Pond Water, oil and sludge and hydraulic fluids 20 PPB to % MANUFACTURING SUPPORT Sewer effluent composites 3 PPB to PPM PPM Vanillin and Black Liquor 2 ND RESEARCH DEVELOPMENT Commercial dishwashing detergents 4 PPB to PPM ' 1242 1242 5432 1242 1254 Pollution Control Pollution Control Pollution Control Determine if detergents are still contaminated iI *ND - None detected HONS 206*55 DETAILS (Cont'd) > 2-21-760.01-13480j 85010, 16300 Page No. 4 Customer Service Alton Box Board Company, Alton, Illinois Duplicate samples of process water, pulp, and paper were sent to Monsanto and three independent laboratories (WARE, Industrial Testing Laboratories, Inc., and Hazelton Laboratories) for comparative PCB analysis. The results were as follows. Sample No. 1 2 3 4 5 Sample Description Estimated Total PCB Level (PPM) Monsanto WARF ITL Hazelton Machine white water 0.008 Primary Head Box 138 >0.01 WB water Pulp after Deckels 0.03 69* Kraft JAX 10-20-71 0.30 62# I.P. Kraft JAX 10-20-71 0.20 0.00 4 ND 0.00 a ND 0.06 0.30 0.20 0.83 4.32 7.07 >0.01 >0.01 >0.01 0.50 0.50 The total estimated PCB levels reported by Monsanto, WARF, and Hazelton are in excellent agreement with each other. The results reported by Industrial Testing Laboratories, Inc. are of by a factor of *\<15X-35X. General Motors Corporation, Friqidaire Division, Dayton, Ohio In the past, Frigidaire has submitted each month two monthly composite samples for PCB analysis. The PCB levels found in the recent samples were considered low enough to be insignificant. A last set of compos ite samples were analyzed to confirm that the plant effluent had no significant level of PCB's. Estimated PCB Level Sample Description (As Aroclor 1242) Plant 2 (10/13-11/9) Plant 3 (10/13-11/9) 0.004 PPM O.OOOg PPM General Electric, Pittsfield, Massachusetts The G.E, analytical laboratories at this site have been analyzing their plant effluents for PCB's for several months now. In an attempt to establish that the PCB levels they were finding were correct, they took five duplicate grab samples for analysis by both laboratories. The levels found by each laboratory are shown in the following table. Sample Description B F G I K Estimated Total PCB Level (PPM) Monsanto General Electric Aroclor 0.005 0.004 0.003 O.OOOg 0.001 0.002 0.008 0.0008 O.OOO5 0.001 1260 1260 1242 1242 1242 MONS 206956 (tv 2-21-760.01-13480, 85010, 16300 Page No, 5 DETAILS (Cont'd) For all practical purposes the agreement between the two laboratories is really quite good. Especially when you consider the low level of PCB's present in these samples and the general problems associated with obtaining duplicate grab samples. At their request, a set of 10 duplicate water samples fortified with Aroclor 1260 were prepared and sent to GE Pittsfield for analysis. The results from the analysis should establish that the minor variations observed in samples B, F, and G are due to sample problems and not the analytical procedure General Motors Corporation, Buick Motor Division, Flint, Michigan Due to continued pressure from Michigan State Regulatory agencies con cerning PCB releases into the environment Monsanto has been analyzing a number of plant effluent and hydraulic fluid samples for them. The results of our most recent analyses are as follows. Buick Sample No. or Description 1 2 3 4 5 7 8 9 10 (Sta. 5) 11 12 13 A & C Pydraul 312A - Die Cast " Machine 15 Pydraul 312A - Die Cast ' Machine 19 No. Blow Down Holding Tank 11-24-71 So. Blow Down Holding Tank 11-24-71 Estimated Total PCB Level as Aroclor 1242 (PPM except as noted) 0.008 0.001 0.005 0.00 04 0.001 0.002 0.002 0.003 0.010 1.3 0.60% 8.4 3 .3 3.1 3.1 2.99% 2.63% 0.69% 0.01% Manufacturing Support J. F. Queeny Plant Sample Description MSD (November) CA (November) CD (12/6-12/17) Estimated PCB Level as Aroclor 1242 (PPM) 0.006 0.042 5.4 - Sample also contained ^19 PPM Aroclop 5432. HONS 20A9S7 2-21-760.01-13480, B5010, 16300 Page No. 6 DETAILS (Cont'd) Since all the estimated PCB levels, with the exception of the MSD sample, exceed the Monsanto internal discharge limit of 10 PPB a number of grab samples will be taken to attempt to determine if the higher levels being observed are real and if so, where the PCB's might be coming from. Monsanto, Seattle A sample of vanillin and vanillin black liquor were submitted for PCB and PCT analysis to establish that these materials were not being contaminated with Pydraul ACA. The Pydraul ACA is apparently used in air compressors associated with the process. Neither Aroclor 1242 nor Aroclor 5432 were detected in either sample. The detection limits were 3 PPB and 1 PPM, respectively. Research and Development Dishwasher Detergents Four samples of dishwasher detergents manufactured by Economics Laboratory, Inc. were purchased from two supermarkets and analyzed for PCB's. PCB's were found in all samples at the levels shown in the following table. Sample Description Electro-Sol, C09141 3991-0520-0471 Purchased at Schnuck's, Creve Coeur Electro-Sol, CO2501 3391-0518-1270, Purchased at Kroger's, St. Louis Estimated PCB Level PPM 0.60 Aroclor 1242 0.09 1242 Finish, 710051 6266-0500-0771 Purchased at Schnuck's, Creve Coeur 0.19 1242 Finish, "Special Formula for Water in'This Area", C08081, 1035-0502-0565 Purchased at Kroger's, St. Louis Soil Migration Study 1.17 1254 Experiments are currently in progress to measure the relative ease with which PCB's can be leached from three types of soil (Drummer Silt Loam, Ray Silt Loam, and Norfolk Silt Loam) by-percolating ground water. The data will be *used to determine if the entry of PCB's to . HOMS 20*95 2-21-760.01-13480, 85010, 16300 Page Ho. 7 the general environment from land fill disposal of Aroclor capacitors could be significant. The procedure being employed involves gravity percolation of distilled water through a 3" X 9" column of each soil. The middle 3" of 6oil being impregnated with 2.5% (w/w) Aroclor 1016. The eluant is then collected and periodically monitored by EC/GC after extraction with hexane. At the present time, only the eluant from the most porous soil, Norfolk Sandy Loam, is beginning to show traces of PCB's (^6 t total eluant volume). Inter-Laboratory PCB Method Check Analysis of all PCB fortified water samples have been completed by both W. G. Krummrich and the Applied Sciences Section. Statistical analysis of the data awaits analysis of these samples by the Anniston plant laboratory. They currently estimate that because of samples with higher priority they will not be able to complete the analysis until about 3-1-72. db HONS 206959