Document EqkEGL2wy9LekDQDeVDX62VnN
FILE NAME Kent KNT
DATE 1959 May 16
DOC KNT156
DOCUMENT DESCRIPTION Journal Article - Air Hygiene - The Journal of
the American Medical Association
1959
---- --
Annual Meeting
Atlantic City + June 8-12 1959
This Issue Exceeds 170,000 Copies
THE JOURNAL
OF THE
American
Medical Association
N.
DEFENDANT'S
ne
EXHIBIT
MAY 16 1959
ORIGINAL ARTICLES
OP.F Ph.D. Lowe M.D. EFFECT
A PRACTICAL DIETARY REGIMEN ON SERUM CHOLESTEROL LEVEL
P. A. Boyer Jr.
T.
Ph.D.
W. Gordier
, and J. D. Ralston M.D.
Indianapolis
AIR
HYGIENEFOR HOSPITALS
Norway Dissecting Aneurysm Pyro-
25 7
zinoic Acid
Amide
and Cycloserine
for Tuberculosis
356
Portugal Physiotherapy of Periarthritis
261
Spinal Amyotrophy Cryptorchism
POISONOUS SNAKE BITES
Thomas McCreary M.D. and Harold Wurzel M.D. Philadelphia
MEDICAL CARE UNDER THE HEALTH INSURANCE PLAN OF GREATER
E. F. Doily M.D. New York
HOSPITAL A SMALL COMMUNITY J. E. SegraveM.sD.
MEDICAL RESPONSIBILITIES
HANDLES A DISASTER
Chicago
IN A CHANGING WORLD
Gunnar
LaCrosse Wis
WHY
CONFERENCE M.D.
THIS CONFERENCE M.D. Brookline Mass
WHY THIS CONFERENCE
E. L. Stebbins M.D. Ballimore
THE RISE OF SPECIALISM IN MODERN SOCIETY
M. Gross Ph.D. Durham N.
SPECIALIZATIPrOiNor
AND THE Ph.D.
PURSUIT Evanston III
OF
EXCELLENCE
NEW YORK
268 272
277
280 283 284 285 289
Iron and Cobalt in Anemia 356
Sweden Combined Treatment of Tuberculosis Calcium Infusion Test for
Sarcoidosis Prolapse of the Uterus
Prolonged Blood Loss at Delivery
Pregnancy The PrediabetPriedicabetic
PePerriiood d
and Obstetrics ...
United Kingdom Little Donign eTrurm-
peters Loud Notes Reactions of Pa
tients Told They Have Cancer Mater-
nity Hospital to Close .... 359
Correspondence
-
Medicolegal Abstracts .............
361 . 362
Medical Film Reviews
. 363
Medical
Literature
THE NATURAL HISTORY OF SPECIALISM IN MEDICINE
294
Medical Literature Abstracts
364
lage Galdston M.D. New York
Book Reviews
391
THE THE
CHALLENGE S. M.
OF SPECIALIZATION
Tenney Hanover N. K.
IN
BASIC
MEDICAL
SCIENCE
EFFECT
OF SPECIALIZATION ON GRADUATE
Pearse M.D. Rochester N.
EDUCATION
IN
SURGERY ..
298 301
Questions and Answers Leukemia After Imadiation Amebic Granuloma Use of Glucocorticoids
MAINTENANCE EDUCATION E. L.
OF STANDARDS IN GRADUATE MEDICAL Turner M.D. Chicago
WORKSHOP CONFERENCE ON SPECIALISM IN MEDICINE
1. RESIDENCY PROGRAM
Wright Adams M.D. Chicago and G. A. Wolf Jr. H.D. Burlington Yi
THE SPECIALTY BOARD 2. J.
PhPihillaaddeelplhpiahia
and
W. S.
W.
BaBnanks ks
M.DM.D. .
Chicago
3. THE RESIDENT AND FELLOW
4.
A. THE
M. Harvey MD HOSPITAL
Baltimore
and
G.
G.
Reader
M.D.
New
York
J. C. Kinsey Ph.D. New York and J. F. Conlin M.D. Bocion
wsssenmeesnntnnnsnn
310
313 315 317 319
Exchange
Transfusions
Transfusions
Sterilization
of
Catheters Action of Testosterone Vita- min B Requirement lococcus
. Requirement
Carriers
Testosterone
Vita-
Testosterone
in Anemia Staphy-
Preoperative Tubercu-
losis Therapy Oral Treatment of
Diabetes Duties of Operating Room
Nurse
. Watkins Transposition
Transposition
.
Clothing Residual Nurse MusPatryalOysdios r of Facial Dermatis Facial
Paralysis
Contact
Contact
DermatDeirmattitiis s
Postural Variations in Pulse and Blood
DEFENSE THE ROLE OF MEDICAL EDUCATION IN CIVIL AND
Postoperative MOBILIZATION Pressure 3 2 2 Genitourinary
J. S. Patterson B.S. Washington D.
Bleeding Pastoperative Cerebrovascular
SPECIAL ARTICLE NOMENCLATURE OF BLOOD CLOTTING FACTORS DIAGNOSTIC PROBLEM
Complications Cataracts Congenital
325 Anomalies Baldness Contact Lenses and Hy-
P. Femur motitis Carcinoma and Thrombophle-
PROGRESSIVE PULMONARY INSUFFICIENCY IN A YEAR WOMAN
328
bitis Shortened
... 395
D. S. Kushner M.D. and S. Szonio M.D. Chicago
EDITORIALS
WASHINGTON NEWS
Strengthening Understanding ...... cee ORGANIZATION SECTION
Denmark Hypofibrinogenemic Hemor-
rhage in Pregnancy
.. cssscssseeeeee
Finland Tuberculous Laryngitis 17
3.50
Radiation Out Hearings Open Senate Group Approves International Re search Bill Flemming Asks Senate to
Television Series in Atlantic City Golf Tournament in Atlantic City
DEPARTMENTS REGULAR
Government Services occ seeue
Electroshock Hydroxycorticosteroid Psychic Levels After Disturbances
After
Thyroidectomy Gastroscopy
Reticulocyte Reaction in Hypoxia 350
France Hospital Teaching Reforms
Hold Line on HEW Spending House Yotes Extension of Law Admitting Aliens With TB FDA Plans Legal Move on
P.R.N. Abuses wc Adv Page 27
Meetings ..8...0..
Adv Page 30
Correction News
Examinations and licensure
Congress of Allergists 351
Iceland Leprosy.....
stems
351
Magazine
Officers of M. A
Report
Adv Adv
Page Page
40 52
Deaths
seteeees
Foreign Letters
. i
sufficiency in India Oxytocics Medical Supplies
Planned
Parent-
From Other Pages
Adv Page 58
Suggestions for Contributors Page 216
Canada Council on Hospital Accredita-
hood Spinal Arachnoiditis Opera-
Tonics and Sedalives
Adv Page 220
tion Nutritional Deficiencies in Men-
tions on the Heart Amebiasis Jaun-
Customs and Idioms
.Adv Page 234
tal Patients Surgical Results of Mitral
dice Brucellosis Chloramphenicol in
The Bright Side
.Adv Page 258
Valvolamy District Care for Mental
Patients Spinal Traction
cco.
Children Encephalilis ...
. 352
Israel Uptake of Radioiodine 355 1
Books Received
Advert..isers Index to
Adv ..Adv ..Adv
Page Page
264 272
Volume 170 No. 3 Published Weekly at 535 North Dearborn Street Chicago 10 Illinois Subscription 15 Single Copy 45 cents
Ready Soon New 7th Edition of Nelson's Pediatrics
Vol 170 No. 3
AIR HYGIENE
71/261
tion in blood cholesterol levels The dietary alteration was accomplished simply easily and inconspicuously and with an excellent degree of patient
acceptability
P. O. Box 1656 6 Dr. Boyer
Dr. C. L. Williams Superintendent of Central State Hospital provided facilities for this study
The com oil margarine used in this study was supplied as Emdee margarine by Pitman Company Indianapolis
References
1. Role of Dietary Fat in Human Health Publication 575
__
National Research Council National Academy of Science 1958. Symposium on Fats in Human Nutrition Council on Foods and Nutrition J. A. M. A. 1890-1925 Aug. 24 1957. Katz L Stamler .; and Pick .: Nutrition and Atherosclerosis Philadelphia Lea & Febiger 1958
2. Enos W. F Holmes R. H and Beyer .: Coronary Disease Among United States Soldiers Killed in Action in Korea Preliminary Report J. A. M. A. 1090-1093 July 18 1953
3. Keys A. and Anderson J. T Relationship of Diet to Development of Atherosclerosis in Man Symposium on Atherosclerosis Publication 338 National Research Council National Academy of Science March 22-23 1954
4. Dawber T. R Moore F. E and Mann G. V Coro-
nary Heart Disease in Framingham Study Am J. Pub Health
4-24 April pt 2 1957
Choles- 5. Rutstein D. D Ingenito E. F Craig J. M and
Mar-
tinelli M Effects of Linolenic and Stearic Acids on
Induced Lipoid Deposition in Human Aortic Cells in
Tissue Culture Lancet 545-552 March 15 1958
6. Margolin E. G Xanthoma Diabeticorum Ann Int
Med 629-635 Sept. 1953
7. Kinsell L. W. and others Dietary Modification of
Serum Cholesterol and Phospholipid Levels J. Clin Endo-
crinol 909-913 July 1952
8. Hardinge M. G. and Crooks H Fatty Acid Composi-
tion of Food Fats J. Am Dietet A. 1065-1071 Oct.
1958. Stefanik P. A. and Trulson M. .: Modifying Fatty
Acid Content of Diet ibid 591-595 June 1958
9. Morrison L. M Nutritional Prografmor Prolongation
of Life in Coronary Atherosclerosis J. A. M. A. 1425-
.
1428 Dec. 10 1955
10. Kinsell L. W. and others Essential Fatty Acids and
the Problem of Atherosclerosis Am J. Clin Nutrition
628-631 Nov. 1958
11. Keys A Anderson J. T and Grande .; Essential
Fatty Acids Degree of Unsaturation and Effect of Corn ( Maize Oil on the Cholesterol Level in Man Lancet
66-68 Jan. 12 1957
12. Vail G. E Cooking with Fats High in Polyunsatu-
rated Fatty Acids J. Am Dietet A. 119-121 Feb.
1959
13. Lewis L. A. and others Serum Lipid Levels in Nor-
mal Persons Findings of Cooperative Study of Liproproteins and Atherosclerosis Circulation 227-245 Aug. 1957
14. Terman L. .: Dietary Management of Hypercholesterolemia Geriatrics 111-114 Feb. 1959
Loe
AIR HYGIENE FOR HOSPITALS
II EFFICIENCY OF FIBROUS FILTERS AGAINST STAPHYLOCOCCIC DROPLET NUCLEI AND BACTERIA DUST
Henry F. Allen M.D. Boston
There is general agreement that air supplied to delivery rooms operating rooms and nurseries
should be free from dust and bacteria On the one
hand pure air is needed to maintain dilution of air-
borne contaminants derived from human sources
inside these areas on the other hand the demon-
strated fact that pathogenic organisms may enter such spaces via conditioning ducts must be guarded against by efficient cleaning of air supply
To insure satisfactory performance over long periods devices for delivering clean air should be simple and trouble and should require a minimum of maintenance Recent developments in the
field of air filtration permit realization of these ob-
jectives at reasonable installation expense and low operational costs This paper reports studies of the arrest of bacteria particles by fibrous filters
in experimental and actual situations
From firmary School
the bacteriology laboratory Massachusetts and the Department of Ophthalmology
Eye and
Harvard
Ear InMedical
A laboratory and operating room study shows that it is possible to provide absolute filtration of bacteria on dust particles and high retention of bacterial droplet nuclei through installation of certain deep glass material in the hospital ventilating system A asbestos paper offered retention in the some range No hospital
should accept an installation which has not been found to retain at least 85 of at-
mospheric dust or its equivalent Careful
performance testing of the installation is
essential
Bacteria in air occur as droplet nuclei or are attached to minute particles of dust lint or skin The former are produced by the atomization of re-
72/262
AIR HYGIENE
J.A.M.A. May 10 1959
spiratory secretions as during talking laughing
coughing or sneezing These droplets approximate 10 in diameter and evaporate almost instantly in air of a relative humidity of less than 100 The
droplet nuclei which remain after evaporation consist of one or more bacteria with a coating of dried organic material They are usually between 1.34 and 2.68 in diameter * and settle at an average rate
of 0.04 ft per minute in still air As convection cur-
rents tend to keep room air in constant motion bacterial droplet nuclei tend to remain in a state of
continuous suspension
bearing dust particles are thought to
vary greatly in size and to be much larger than droplet nuclei Most of them settle at 1 or 2 ft per
minute in still air but some may be continuously
suspended in moving air
may be bonded together by phenolic resins or papers of cellulose and asbestos glass glass and asbestos or ceramic fibers with or without a binder A great increase in filtering surface can be achieved
by pleating these materials Air velocities through
the medium usually range from 5 to 25 ft per min ute In general units presenting a superficial area of 4 sq ft provide an air flow of 1,000 cu ft
per
minute at an average duct velocity of 250 ft per minute Retention of particles by these mediums is
largely the result of inertial impaction of particles on fibers In addition the static gas film around
fibers may interfere with the passage of particles
Although physicians do not ordinarily carry out performance tests on air filters an understanding of the basis for efficiency rating is important This is
because a filter which is highly efficient against
Fig blower system 1 nitrogen supply line 2 flow regulator 3 DeVilbiss 40 nebulizer 4 location of dispersion disk 5 sampling point MF holder 6 mercury manometer 7 vacuum pumps 8 filter medium in holder 9 water manometer 10 filter holder 11 fan 12 calibrated bag not used during tests 13 wet and dry bulb thermometers gauge
Ventilating air is cleaned by passage through devices which operate on one of the following principles 1 impingement on mediums coated with
viscous material 2 impaction on fine fibers of dry porous mediums 3 electrostatic precipitation or 4 washing or scrubbing by passage through wet cells or fine sprays
The antibacterial efficiency of viscous and wet
cell filters is too low to warrant their use in critical
hospital arcas Electronic air cleaners have been
reported to possess high efficiency against air-
borne bacteria and viruses but will not be discussed in this paper Fibrous filters may be made of
fabric mediums of wool felt or cotton batting
or cloth deep mats composed of glass fibers averaging between 0.8 and 3.0...in diameter which
particles 10... in diameter may be extremely inefficient against particles l in diameter A case in
point is the poor performance of viscous filters
against atmospheric dust
Deep mats composed of glass fibers averaging between 0.8 and 3.0 in diameter are rated by the National Bureau of Standards NBS discoloration test with atmospheric dust used as the test
material that is against particles averaging 0.5 in
diameter Their efficiency increases with the useful
life of the filter as particles build up on the filter face Efficiencies from 35 to 95 over the life of
different grades of filters are achieved at the rated
velocity The initial resistances of the various me-
diums range from 0.14 to 0.48 in water gauge at the
rated velocity
Vol 170 No. 3
AIR HYGIENE
73/263
Paper filters are rated by the NBS discoloration test or in terms of their efficiency against dioctyl phthalate DOP smoke an aerosol of particles uniformly 0.3 in diameter Absolute filters achieve a minimum guaranteed arrest of 99.95 against DOP smoke Their retention of bacteria approaches 100 This high efficiency is obtained at the cost of in-
creased resistance to air flow
Experimental Studies
There are few studies of the efficiency of fibrous
mediums against organisms Decker and co-
workersfiber tested the efficiency of three grades of
fiber pads and of two types of mineral papers against freshly atomized aerosols of Serratia indica and Escherichia coli T bacteriophage A singlethickness pad possessing the characteristics of Fil-
terdown FG retained 99 of the bacteria and
98 of the bacteriophage Penetration of the glass-
asbestos paper was 2.8 to 14 per 10 million organ-
isms of type E glass paper 1 to 2 per 100 million organisms
The downstream section of the filter holder in-
corporated a fine stiff stainless steel screen to pro-
vide backing for the filter medium being tested The screen was soldered to the flange and the
interstices of the meshwork were filled with aluminum powder in a plastic base so as to present a flush smooth border 1.25 in wide around the
periphery of the filtering surface A gasket of spun
glass fiber was cemented to the downstream flange
and one of 0.12 foam rubber to the upstream
flange Clamps were used to maintain firm pressure through the opposed flanges on the filter medium
:
between the gaskets
The ducts were equipped with dispersion disks
located five duct diameters upstream from each
sampling point to provide thorough mixing of the aerosol before sampling The sampling points were
located 20 in downstream from the intake and
from the filter holder respectively All joints were made airtight with sealing tape
Air samples were taken through angle glass tubes 6 to 8 mm in diameter inserted through the
TABLE Characteristics of Fibrous Filter Materials
Code Trade Name
Material
Diameter of Glass Fiber Emciency %
... B. Ceram-
le FG ... ...
CH Micretain
Fiberfrax Filterdown Aerosolve 95 Aerosolve 85
Glass paper asbestos paper
Aluminum silicate paper Glass mat Glass mat
9 Glass mat
1.0
1.0
2.4 1.25
1.0-1.1
0.8-0.9
*
During useful life of Alter Dioctyl phthalate 0.3 # smoke $ National Bureau of Standards discoloration test $ At rated velocity
93.97 95
83 90-95 90-95 80-65
Rating
Test
DOP DOP
DOP
NBS NBS NBS
:
Rated
Velocity Ft per Blin
Pressure Drop 10. H
Efficiency vs.
Bacterial
Droplet
Nuclei %
Efficiency vs. Dustborne Bacteria %
5.5
0.90
99.97
100
5.0
0.40
96.7-98.1
100
5.0 21.0 23.0 25.0
0.18
97-98
99
0.48
87-99
99
0.35
89-98
99
1-670
5-1-69
vee
Because the bacterial species used by these workers is particularly vulnerable to drying and because neither it nor the bacteriophage is likely to be
encountered in environmental air it seemed de-
sirable to confirm these studies and to extend them
to a pathogenic species more resistant to drying to bacteria attached to dust particles and to other filter materials At the same time an opportunity was afforded to compare two sampling techniques in the light of newer knowledge regarding one of them With these purposes in mind the following
test situation was established
Materials blower system was adapted
for bacterial sampling of air upstream and downstream from the filter medium The assembly fig 1
consisted of several feet of round galvanized sheet metal duct 2 in in diameter a filter holder com-
posed of two sided funnels with flanges by means of which the funnels could be clamped base to base and a fan at the downstream end of the
system The filtration surface was 6.5 in on a
with an area of 0.29 sq ft
side
duct wall and pointing upstream in the center of
the duct The air was sampled for bacterial content
either by filtration through cellulose ester gel mem-
branes Millipore filters MF or by bubbling
through critical orifice liquid impingers containing
200 cc of 3.2 heart infusion with 0.2 gela-
tin solution the stem being 4 cm from the bottom of the container The pH of the impinger fluid was
7.2 A loopful of a silicon antifoaming agent Anti-
foam A was added to each impinger Sampling
rates were 2.0 to 4.5 liters per minute a pressure
drop of 24 in Hg being maintained across the critical orifices during operation The dimensions of the sampling tubes were selected to make the sampling velocity approximately isokinetic with the central
duct velocity Fresh aerosols were produced by atomization of
bacterial suspensions from a DeVilbiss 40 nebulizer activated by nitrogen from a commercial cylinder at a Bow rate of 6.4 liters per minute hour broth cultures of Staphylococcus aureus Food and Drug Administration strain 209 American Type Culture Collection 6538 were diluted with sterile
74/264
AIR HYGIENE
J.A.M.A. May 16 1959
distilled water to a degree suitable for sampling
after nebulization The organisms were less than
lu in diameter and were highly dispersed Dry aerosols were produced by insufflating fine
dust obtained from the filter cones of ward vacuum
cleaners into the duct from a powder blower These
coated cones retain almost 100 of airborne
bacteria contacting them The principal species recovered from this dust were represented by strains of yellow and white staphylococci hay bacilli sarcinae and assorted molds It is probable that the bacterial particles were not in a state of high
dispersion in these aerosols
The properties of the several filter materials
samples tested are shown in table 1. At least three
from one or more lots of each medium were tested and at least three trials were made with each
sample
Operation humidity of the room air was adjusted to the desired level by allowing steam to flow from the chamber of an autoclave into the room The rate of air flow through the system was adjusted by controlling the fan speed to produce
the desired velocity at the filter face Flow rates
Table Retention of Nebulized Staphylococci
by a Single Pad of Filterdown FG
Colonies
Sampler
Upstream
Mulpore Alter oe
257
Impinger ..,.......cceesescesceees Implager Millipore filter .........
920
3.57
per Literi
Downstream 3 0.1 Par
Temperature 23 C relative humidity 31 Sampling rate 2 liters per minute
Efficiency T
Efficiency
5.68 12.93
were measured directly by timing the inflation of a calibrated bag of weight polyethylene capacity 5.5 cu ft fig 1
With air flowing through the system at the desired rate fresh or dry aerosols were introduced at
the intake and allowed to flow for from 1 to 30 min-
utes before sampling was begun Sampling was carried on simultaneously at the upstream and downstream sampling points usually for 60 seconds
At the end of each run the filter membranes
were transferred to the surface of trypticase soy
agar plate or aliquots of the impinger fluid were filtered through Millipore filters HA type which
were incubated on the same solid medium After
incubation of the plates at 37 C for 24 hours and
22 C for 12 hours colonies were counted under mag-
nification using the ophthalmic biomicroscope and
slit lamp Zeiss Opton
Conditions and Controls The temperature dur-
ing these experiments varied from 21 to 24 C the
relative humidity was adjusted between 31 and
71 The construction of the system insured that no
Organ- room air was drawn into it or the samplers other
than that which was introduced at the intake _ isms present in the room air were not of the test
species and were numerically insignificant in pro-
portion to those in the artificial aerosols and their
occasional presence appeared to have no effect on
the results
In a representative number of trials but not in all
the filters and the downstream sections of the filter
holder and ducts were sterilized by hot air between
tests Failure to sterilize them in other trials
ap-
peared to make no difference in the results of these tests presumably because the test organisms were not present on or were not liberated by blow from the filter pads or the interior surfaces of the ducts in significant quantities The sampling mem-
branes were sterilized by autoclaving
The experimental techniques used in this study are described more fully in the first paper of this series At the relatively low filtration velocities and the relatively small sampling volumes used in the present study there was no evidence that vari-
ation of the relative humidity within the range re-
corded above had any effect on either the efficiency of filtration by the glass materials or the recov-
ery of organisms on the sampling membranes MF In contrast to conditions in the former study " there was no warming or drying of air during its passage through the blower system Humidification of
sampled air by passing it through 18 by in tubes containing rolled moist filter paper failed to increase the yield of organisms on the MF in com-
parative tests with air of 39 relative humidity at a sampling rate of 2 liters per minute
There was no evidence of increasing penetration of the fibrous materials with time Rather it was
clear that accumulation of dust on the filters in-
creased their retention of bacteria Filterless trials
indicated an expected recovery rate of 90 or better
at the downstream sampling point No correction
for this factor was made in calculating efficiency of
filtration
oo
1 Results findings recorded in table refer to
retention of bacterial droplet nuclei by new unused filter materials in terms of the dry aerosol assay
Millipore filter sampling technique When parallel
sampling by this method and by liquid impingers
operated at an identical rate 2 liters per minute
was conducted simultaneously at both the upstream and the downstream sampling points impinger
counts were 3.3 to 3.57 times those on the MF at the
upstream point and 2.75 to 2.9 times those on the
MF at the downstream point In spite of the threefold disparity in absolute values filtration by the
glass medium demonstrated by both methods was of the same order of efficiency It is presumed that the larger number of organisms recorded by the impinger represents both break of bacterial
aggregates by it and decay of organisms after con-
tacting the MF surface The former factor could
account for the slightly higher efficiencies demon-
strated by the impinger technique since aggregates
Vol 170 No. 3
AIR HYGIENE
75/265
which would produce only a single colony on the MF would presumably be arrested by the glass filters more readily than single cells The fact that the efficiency of the more retentive materials appeared nearly the same by both methods is consistent with monodispersion of the particles in the aerosol A typical trial is shown in table 2
Of the deep materials clean thickness pads of Filterdown 50 ordinarily retained 98.5 to 98.7 of freshly nebulized bacterial aerosols Impinger samples confirmed the 99 retention reported by Decker and his group for the same me: dium However one substandard lot was received
which passed up to 15 of droplet nuclei This was returned to the manufacturer who confirmed the poor performance of the sample and stated that
steps had been taken to prevent release of sub-
standard lots in the future thickness pads of Aerosolve 95 a deep medium of considerably lower resistance to air flow than Filterdown FG
showed an average retention of 95 with a range from 89 to 98.5 in different runs Retention of
droplet nuclei by laden filters was higher than by clean filters Both mediums retained essentially 100 of bacteria dust particles produced by the powder blower It is reasonable to assume that any medium retaining 90 or more of an aerosol of droplet nuclei would retain essentially 100 of bacteria attached to atmospheric dust particles
Unlike absolute filters deep filters are not individually guaranteed as to their efficiency by the
manufacturer This fact suggests the need for test-
ing the performance of individual filters used in critical situations especially in view of the variation we have observed in different lots of deep
material
Penetration of the glass and asbestos papers by droplet nuclei was roughly in proportion to their DOP ratings The high retention of these mediums was achieved only at a resistance to air flow significantly greater than that offered by the deep mediums A cotton surgical face mask retained less than 20 of staphylococcic droplet
nuclei
Field Studies
Because of abnormally high bacterial counts in
the operating rooms a survey of the two operating suites was undertaken With use of titanium tetra-
chloride as an indicator it was determined that air
from the corridor was being drawn into each of the four eye operating rooms and exhausted through
ceiling ports in the scrub rooms and anesthesia
rooms When the doors to the corridor were closed
a brisk flow of air under them into the operating rooms was apparent The air flow at either end of the main corridor of the operating suite was then
tested and it was found that air was being drawn
under and between the double doors which opened
into the main stair well of the hospital at one end
of the corridor and into the ear nose and throat outpatient clinic at the other A similar situation was encountered in the ear nose and throat operating suite on the floor above
A survey by ventilating engineers confirmed
these findings It was brought out that the supply
fans had been slowed in order to reduce the intake
of outdoor dust through viscous panel filters At the
same time exhaust fans in the anterooms continued
to operate at their original speed so that a negative
air pressure was created in the operating rooms The parallel between this situation and that re-
ported by Blowers and workers is striking
In accordance with the consultants recommenda-
tions the exhaust ports were sealed off and fan
speeds increased to the maximum 1,700 revolutions
per minute creating a positive pressure in the oper-
ating rooms Air escaped by exfiltration under doors
and through louvers into surrounding areas The total air flow thus provided was between 500 and
600 cu ft per minute for each operating room with
100 outside air providing about 12 air changes per hour Viscous filter panels in the intake ducts
TABLE Performance of New Filters to Operating Rooms Against Nebulized Staphylococcifi
Room
Colonies per Cu Ft
a y
Efficiency
Upstrena Downstream
%
1 e cece es crepe een cn tteesceeeecees ba
5.40 X
160
97
170
95
4
... pas
97
*
Pressure drop 0.24 water gauge 15min trials at 2 liters per minute
for outside air were supplemented by banks of deep glass filters Acrosolve 95 in the distribution ducts to each operating room
In order to test the efficiency of the completed
installations samples were taken from the ducts at
suitable locations upstream and downstream from
the banks of filters while freshly nebulized and dry dust aerosols were being introduced through open-
ings in the duct wall into the air stream from the supply air fan The first tests showed penetration of the order of 50 The fault was traced to defective
installation and token calking of the cadmiumplated filter frames in the ducts and to omission of the rods used to seat the filter cartridges firmly against the felt gaskets in the frame This omission was contrary to the manufacturer's specifications In one instance the tapping screws used to fas-
ten the water gauge manometer to the duet wall had forced the filter frame inward away from the duct After correction of these deficiencies reten-
tion of the order of 95 was found for droplet nuclei table 3 The effect of ventilation on the concentration of droplet nuclei Staph albus nebulized into an operating room is shown in figure 2
76/266
AIR HYGIENE
J.A.M.A. May 16 1959
Comment
of Selection of a filter for a given purpose represents
a compromise between high efficiency and low pressure drop inversely reflecting power cost and serv-
ice life For air supplied to hospital operating
rooms delivery rooms and nurseries this compro-
mise must be resolved in terms the expected
microbiological and particulate challenge to the filter and the efficiency of cleaning required of the
filter against the expected challenge
The state of bacteria and molds in outside atmos-
pheric air is not entirely clear Colebrook and "
Cawston found a preponderance of nonpatho-
genic bacteria and molds with occasional colonies
Log
2.0 _~
1.8
Temperature 24C Relative humidity 34
samples
samples
.6
samples
samples
air
|e
in
bacteria
bacteria
semiabsolute mediums would make their use appear uneconomical for air supplied to spaces in which
human beings are continuously liberating organisms
from their persons
loosely No filter medium can be better than the
of its installation As air seeks the path toifghtlneeassst
resistance the volume of air bypassing a
installed filter bank will increase with the
of dust in the filter bed At the same tibmueillodw
manometer readings may give the erroneous
sion that the filter bed is operating well beilmopwreist-s
maximum the
permissible
pressure
drop
when
actually
reverse is the case
Unlike a plumbing installation a faulty air filter assembly shows no immediate sign of leakage Be-
cause the load of particles entering the air intake
during any short period of time is small dust and bacteria may accumulate before spilling over into a channel If alternate moisture and drying exist at an upstream location bacteria which have proliferated during the moist phase may strike the filter face en masse during the dry phase Detection of
leakage would thus depend on prolonged sampling fortuitous sampling during a period of spillage or
performance tests using a standard challenge of
dust or bacteria
bacteria 1.2
bacteria
of
concentration tol
concentration
concentration
concentration concentration
concentration 0.8
concentration
initial
initial 0.6
of of
cent
cent ^
per
LOO10
LOO10 0.2
LOO10
0 Humidified molecular membrane sample
Xx Electrostatic precipitalian sample
5
10
151
201
25
minutes |
Fig Rate of disappearance of Staphylococcus albus
from ventilated and unventilated rooms
of Staph aureus in air sampled on the roof of their hospital There was no way of telling whether these organisms were floating or attached to dust particles The infrequency of the common human respiratory pathogens in their samples suggested that few bacteria existing as droplet nuclei survive drying and exposure to atmospheric conditions out
of doors
The efficiency of the deep mediums Filterdown FG and Aerosolve 95 together with a high rate of flow at a low pressure drop across the filters
renders them acceptable for filtration of ordinary
atmospheric air supplied to critical hospital areas The high pressure drop across the absolute and
Neither the contractor nor the consulting engi neer carried out a performance test of the filters
installed in the ducts leading to our operating
rooms Moreover the consultant failed to detect the
contractor's failure to meet the manufacturer's
floor specifications for installing the filters No hospital
should accept an installation which has not been
found to retain at least 85 of atmospheric dust or
its equivalent Ventilating engineers should be
pre-
pared to certify the initial performance of any high-
efficiency filter system and to check any sam-
ple of fibrous medium for substandard efficiency
A correctly installed bank of deep glass
filters protected by suitable viscous or electronic
prefilters requires remarkably little maintenance
After six months of continuous hour operation
the pressure drop across the filters for our operating
rooms had risen from 0.25 to 0.42 in of water maxi-
mum allowable dirty drop is 0.8 in of water Other
advantages include disposability ease of replace-
ment and retention of dust during filter changes
Heavy particles on the duct
should be re-
moved by vacuum cleaning at the time of filter
changes
The ceramic paper is intended for temper-
ature dust filtration and would not normally find an application in hospital ventilating systems The absolute mediums because of their higher resistance to flow are not ordinarily used in air supply systems for hospitals
The asbestos paper Micretain is stated by the manufacturer to be suitable for use in supply systems to operating rooms A cartridge presents 200 sq ft of pleated filtering surface and permits an
Vol 170 No. 3
AIR HYGIENE
air flow of 1,000 cu ft per minute at a clean rated
pressure drop of 0.4 in water gauge Because of its higher efficiency greater uniformity and longer
service life 4,000 hours with adequate prefiltration
the manufacturer believes that this will be an eco-
77/267
ticles and high retention of bacterial droplet nuclei A asbestos paper intended for
offered retention in the same range hospital use
200 Beacon St. 16
nomical filter for critical hospital air supply situ-
ations
The excellent retention rate of several fibrous
filters suggests the desirability of designing ventilating systems to permit partial recirculation of air The advantages of recirculation in permitting easier
and cheaper control of temperature and humidity
are obvious especially where explosive vapors are not in use Even when volatile agents are being
^"sedThomas " feels that the present requirement
of 100 outside air is unreasonable and that 50
recirculation would be perfectly safe at the same relative humidity
In ordinary ventilating situations the need to sterilize fibrous filters in place does not arise If it became necessary to sterilize a heavily contami-
nated exhaust filter this could be done with beta-
propiolactone in the vapor phase 16 or with ethylene
oxide in suitable combination with an inert gas
The high efficiency of Filterdown FG permits
other applications in the field of air filtration At the
suggestion of Snow this material has been em-
ployed as a tertiary filter in an industrial vacuum
cleaner Kent Quiet Junior which is suitable for use in hospitals At a volume output of 135 cu ft per minute and at an air velocity of 210 ft per min ute through the medium a thickness pad of Filterdown FG placed upstream from the twin
motor intakes retained 99.8 of nebulized
staphylococci either alone or in conjunction with
the normal primary paper bag and secondary
cloth bag filters of the machines The higher efficiency observed at the higher velocity is consistent with arrest by inertial impaction
The low resistance to air flow of Aerosolve 95
and 85 suggests a possible application in surgical
masks We are currently exploring the use of these materials as a better means of checking bacteria of
respiratory tract origin at their source
This study was supported in part by the Massachusetts Eye and Ear Infirmary through its Bacteriology Research
Fund
Mr. Werner Mueller Jr. supplied parts of the mechanical equipment and Mr. David Feigenbaum supplied figure 1
References
1. Fredette .: Bacteriological Efficiency of Condi-
tioning Systems in Operating Rooms Canad J. Surg 226-
229 April 1958
i
2. Bourdillon R. .: Practical Advantages of Different Methods of Air Disinfection in Studies in Air Hygiene
Medical Research Council Special Report Series No. 262 London His Majesty's Stationery Office 1948 pp 311-318
3. Wells W. .: Airborne Contagion and Air Hygiene
Ecological Study of Droplet Infections Cambridge Harvard
University Press 1955 p 9
4. Phelps E. B State of Suspension of Bacteria in Air as
Measured by Settling Rates in Aerobiology edited by F. R. Moulton American Association for the Advancement of Sci-
ence publication no 17 1942 p 136
5. Wells p 44
6. Friedlander S. K Silverman L Drinker P and First
M. W Handbook of Air Cleaning Washington D. C. U. S. Atomic Energy Commission 1952
7. a Decker H. M Geile F. A Moorman H. E and Glick C. A Removal of Bacteria and Bacteriophage from Air by Electrostatic Precipitation and Spun Glass Filter Pads
Heating Piping & Air Conditioning Am Soc Heating & Ventilating Engineers J. 125 Oct. 1951. b Lidwell O. M Bacterial Filtration Efficiency of Electrostatic Air
Cleaner J. Inst Heating & Ventilating Engineers 139
1951
8. Decker H. M Harsted J. B Piper F. .; and Wilson M. E Filtration of Microorganisms from Air by Class Fiber Media Heating Piping & Air Conditioning Am Soc Heat-
ing & Ventilating Engineers J. 155 May 1954. Refer-
ence 7a
9. Rosebury T Experimental Borne Infection Baltimore Williams & Wilkins Company 1947 pp 90-92 Ferry
R. M Brown W. F and Damon E. Studies of
Viability of Stored Bacterial Aerosols Death Rates
Loss of of Sev
eral Pathogenic Organisms in Relation to Biological and
Structural Characteristics J. Hyg 125-150 March 1958
10. Cown W. B Kethley T. W and Fincher E. L
Critical Liquid Impinger as Sampler for Bacterial
Aerosols Appl Microbiol 119-124 March 1957
11. Allen H. F Air Hygiene for Hospitals Arrestment of Airborne and Dustborne Staphylococci by Hospital Vac-
Conclusions
uum Cleaner J. A. M. A. 553-559 Feb. 7 1959
A supply of clean air cannot by itself eliminate infection but a supply of unclean air cannot be
12. Blowers R Mason G. A Wallace K. R and Walton M Control of Wound Infection in Thoracic Surgery Unit Lancet 786-794 Oct. 15 1955
tolerated in a hospital Adequate cleaning of air by filtration through efficient fibrous mediums or by electrostatic precipitation is mandatory for operating rooms delivery rooms and nurseries Perform-
ance testing of any installation for efficiency
fine filtration is essential If an electronic air cleaner
is used incorporation of an efficient fibrous filter
13. Gaden E. L. and Humphrey A. E Fibrous Filters for Air Sterilization Ind & Eng Chem 2172 1956
14. Colebrook L. and Cawston W. C Microbic Con-
Council tent of Air on Roof of City Hospital at Street Level and in
Wards in Studies in Air Hygiene Medical Research Special Report Series No. 262 London His Majesty's Stationery Office 1948 pp 233 241
15. Thomas C. .: Air Conditioning in Hospitals Anesth & Analg 32-35 Jan. 1957
between it and the space being ventilated is essential Two deep glass materials were found
to provide absolute filtration of bacteria on dust par-
16. Hoffman tone Vapor as Sept. 1958
17. Snow D.
R. K. and Warshowsky .: Propiolac-
Disinfectant Appl Microbiol 358-362
L Unpublished data