Document EqYV7K7xjO6ZK6E1EOexweY6b

Boilers The Brownell Company Dayton, Ohio Sales Representatives-in All Sections of the Country Steel Heating and Power Boilers, Feed Water Heaters, Tanks,Breechings, Stacks, Boiler Castings, Steel Plate Construction and Steam Engines. Since 1855, when The Brownell Co. was established, this company has been manu facturing a complete line of High Grade Boilers and other equipment. The Brownell Smokeless Firebox Boiler is designed and constructed to burn any kind of fuel economically and with- out smoke. Brownell Fire box Boilers are mechanically correct and insure long life. Brownell Heating Boilers have generous and properly designed fireboxes, permitting complete combustion and high efficiency. Brownell ratings are very con servative, only the parts of boiler below the normal water level and coming in actual contact with the hot gases being considered as effective heating sui face. Brownell Boilers will carry the number of square feet of direct radiating surface or equivalent given in opposite tables if sufficient radiation is installed to heat the building to the required temperature. Brownell Firebox Heating Boilers are regularly built according to the A. S. M. E. Code for 15 lb. working pressure but will be furnished for pressures up to 100 lb. at an increased cost. Brownell Return Flue Portable--Smokeless Type--Bulletin B-6A Brownell Brick-set Firebox Boiler--Direct Draft Type Bulletin B-6 Brownell Return Flue Portable--Direct Draft Type--Bulletin B-6A 290 Brownell Brick-set Firebox Boiler--Smokeless Type Bulletin B-6 The Brownell Co. Boilers BROWNELL DIRECT DRAFT PORTABLE BOILERS Boiler No.............. -------Capacity--Steam, bq. h L... CpMity--Sq. Ft.... Approximate Weight................ Diam. of Boiler, In....... Length Boiler Overall. Ft.. In.. 407 408 409 2300 2900 3500 4100 4800 5800 6900 7400 8300 48 48 48 8-6 9-6 10-6 410 4000 6600 9000 54 10-0 411 41? 413 414 415 416 417 418 419 420 421 422 423 424 4500 5000 5500 6000 7000 8U0U 9500 11000 13000 15000 17500 20000 25000 28000 7400 R300 9100 .9900 11600 13700 16/00 18200 21500 2481X1 28500 32000 40000 45000 9800 10600 13200 14100 15900 17300 19600 21000 23000 24800 27100 29000 35000 38000 54 54 60 60 60 '60 66 66 72 72 78 78 84 84 11-0 17-0 12-6 13-6 14-0 15-6 15-6 I/-8 15-10 i y--4 17-10 19-10 20-0 22-0 Heating Surface. Sq. Ft........... 293 333 373 Size of Steam. In........................ 6 6 6 Size of Return. In...................... 4 4 4 Height of Water Line. `n. .. . - 69 69 69 427 487 66 4 '4 76 76 537 6 4 76 614 7 5 78 670 7 5 78 698 7 5 78 761 7 5 78 936 1061 1224 1356 1539 1796 2227 2478 8 8 8 8 8 8 10 10 6666 6666 87 87 92 92 92 92 98 98 Height. Floor to Top of Shell. 84 84 84 91 91 91 95 95 95 95 108 108 109 109 110 110 116 116 Space Required to Open Rear Doors. In.. ....................... 25 25 25 Diam. Breeching. In......... 22 22 22 Diam. Stack. In----- . 20 20 20 Min. Height Stack. Ft. ... 50 50 55 Diam. Breeching. 2 Boilers, In. 30 30 30 Diam. Stack. 2 Boilers; In... . 28 28 28 28 24 22 55 34 31 28 24 22 55 34 31 28 24 22 60 34 31 30 26 24 60 38 34 30 26 24 60 38 34 30 25 26 65 40 36 30 28 26 65 40 36 35 30 28 65 44 40 35 32 30 /0 46 42 37 34 32 /O 50 46 37 34 32 /O 50 46 40 36 34 80 52 48 40 36 34 90 52 48 43 43 40 40 38 38 90 100 56 56 54 54 Minimum Height Stack, 2 Boilers, Ft......................... 60 60 65 65 65 70 70 70 75 75 75 80 80 80 90 100 IQQ too BROWNELL SMOKELESS PORTABLE BOILERS Boiler No...................... - -.......... 307 308 309 Capacity--Steam. Sq. Ft......... 3000 3500 4000 310 4500 311 5000 312 5500 313 6000 314 6500 31.S 7500 316 317 318 319 320 321 322 323 324 850(1 t(XNK) I2IKX1 14000 16000 18000 20000 25000 30000 Capacity--Water. Sq. Ft.------ 5000 5800 6600 7400 8300 9100 9900 1070(1 12400 14000 16500 19800 23100 26400 29700 33000 4000U 48000 Approximate Weight................ Diam. of Boiler. In.............. Length Boiler Overall. Ft.. In. 7800 8600 9300 10400 11100 11900 14300 15300 16900 48 48 48 54 54 54 60 60 60 8-7 9-10 10-10 10-7 11-7 12-7 12-7 13-7 15-1 17800 20000 21900 24000 25500 27900 28000 35000 41000 60 66 66 72 72 78 78 84 84 16-1 15-9 17-9 16-6 17-8 17-8 18-8 20-1 24-1 Heating Surface. Sq. Ft........... 307 381 405 472 526 579 631 687 766 877 922 1062. 1255 1370 1529 1601 2090 2655 Size of Steam, In........................ 6 6 6 Size of Return, In...................... 4 4 4 6 4 66 4' 4 7 5 7 5 7 5 7 5 88 6 .6 8 6 8 6 8 6 8 10 10 666 Height of Water Line. In......... 69 69 69 76 76 76 78 78 78 78 87 87 92 92 92 92 103 103 Height. Floor to Top of Shell. In.............................................. 84 84 84 92 92 92 95 95 95 95 108 108 109 109 110 110 118 118 Space Required to Open Rear Doors. In... ................. 75 75 75 28 28 28 30 30 30 30 35 35 37 37 42 42 44 44 Diam. Breeching, In................. 77 22 22 Diam. Stack. In......................... 20 20 20 24 22 24 22 24 22 26 24 26 28 24 . 26 28 26 30 32 28 - 40 34 44 32 32 36 44 36 34 40 38 40 38 Min. Height Stack. Ft............. 50 55 55 55 55 60 60 60 65 65 65 70 70 70 80 90 90 100 Diam. Breeching. 2 Boilers, In. 30 30 30 34 34 34 38 38 40 40 44 46 50 50 52 52 56 56 Diam. Stack. 2 Boilers, In... . 28 28 28 31 31 31 34 34 36 36 40 42 46 46 48 48 54 54 Min. Height Stack, 2 Boilers, Ft............ ................................. 60 65 65 65 65 70 70 70 75 75 75 80 80 80 90 100 100 no BROWNELL DIRECT DRAFT BRICK-SET BOILERS 1 2 3 4 5 6 7 8 9 10 11 12 1.3 14 15 16 17 18 19 20 900 1050 1200 1400 1700 7000 7000 2600 3000 3500 4000 4500 5500 6300 7300 8700 10000 11000 12000 14000 1500 1700 2000 2300 2800 330(1 330(1 43<KI MXXI 580(1 6600 7400 9100 10700 12400 14400 16300 18200 I980C 23100 2800 3000 3200 3600 4700 4600 5200 5600 6000 7000 7800 8600 9700 11000 13500 14800 16000 17400 18600 20400 30- 30 30 36 36 36 42 42 42 48 48 48 54 54 60 60 66 66 72 72 6-6 7-6 8-6 7-6 9-0 10-6 8-6 10-0 11-6 10-6 12-0 13-6 14-0 16-6 13-6 18-0 16-0 18-0 16-0 18-0 113 128 143 193 231 268 269 317 364 390 444 499. 373 683 755 887 971 1097 1183 1343 4 3 4 4 4 4666667 7 7 7 7 8 7'A M 3 3 3 3 4 4 4 4 4 5 5 5 5 5 6 6 6 6 Height of Water Line, In....... 53 55 53 59 59 59 61 61 61 65 65 65 67 67 75 75 80 80 85 85 Work. In........... ................. 70 70 70 77 77 77 83 83 83 90 90 90 96 12 14 16 16 18 18 20 20 22 22 24 24 28 12 12 14 14 16 16 16 18 20 70 22 72 26 40 40 40 40 40 45 45 45 45 45 50 50 30 26 28 30 30 34 36 38 24 26 28 28 30 32 34 % 108 108 114 114 120 120 28 32 32 32 32 36 36 26 30 30 30 30 34 34 30 33 35 60 60 60 60 38 40 40 40 42 44 46 34 36 36 36 38 40 42 Ft........................................... 50 50 50 50 50 50 55 60 60 70 70 70 70 70 Approximate Shipping Weight........ Heating Surface. Sq. Ft.................... Height Floor to Top of Brick Work,- Space Required to Open Rear Doors, In........... .... Min. Height Stack. 2 Boilers. Ft.. . BROWNELL SMOKELESS BRICK-SET BOILERS 107 2600 4300 6100 42 9-10 309 6 4 61 108 3100 5100 6700 42 11-4 359 6 4 61 109 3600 5900 7200 42 12-11 409 6 4 61 110 111 4000 4700 6600 7800 8400 9100 48 48 12-4 13-10 448 506 66 44 65. 65 112 5500 9100 9800 48 I'M 563 7 5 65 113 6500 10700 12300 54 15-10 643 7 5 67 114 7500 12400 13600 54 18-4 756 7 5 67 115 8500 14000 16000 60 17-10 851 7 5 75 116 10000 16500 17400 60 20-4 987 7 5 75 82 82 82 89 89 69 95 95 107 107 22 22 22 25 25 25 28 28 30 30 22 22 24 24 27 27 30 30 34 34 20 20 22 . 22 24 24 28 28 32 32 50 50 50 50 55 55 60 60 60 60 26 30 34 34 36 36, 38 40 42 42 26 28 30 30 32 32 34 36 38 38 60 60 60 60 60 60 70 70 70 75 291 117 11500 19000 19400 66 18-4 1074 8 6 80 113 35 36 34 70 44 40 75 118 13000 21500 21000 66 20-4 1204 8 6 80 113 35 36 34 70 46 42 80 119 14000 23100 22400 72 18-4 1303 8 6 86 1)9 37 38 36 70 48 .44 s'80 120 16000 26400 24300 72 20-4 , 1468 8 6 86 119 37 . 38 36 70 50 46 80