Document EqXq2XrL3E6x7GLLEzzo7dQk0

I0WANK HI-TEST SERIES HT Two-Pass Portable Tubular Boiler for High Pressure Steam THE KEWANEE HI-TEST TUBULAR BOILER is now in production ready for immediate duty in any Steam usage for Power service or Industrial Process. HT-SERIES has been newly contrived to fit modern ways and means of manufacture. It is planned with due regard for easy handling. Even when performing under critically heavy loads this fusion-welded steam generator is found highly efficient, offering continued "economies in fuel year in year out. Characteristically portable, the KEWANEE HI-TEST TWO-PASS boiler is compact yet extra rugged, built in full conformity with A.S.M.E. Boiler Code. Fabrication by qualified welders using latest facil ities reflects a modem practice in streamline construction for high pressure. The metal casing is de signed for a refractory lined firebox or combus tion chamber, making it entirely self-contained. All fuels whether solid, liquid or gas. hand or mechanical fired from front, side or rear may be burned with eco* nomical results wherever high pressure live steam is consumed, even if the condensate is not returned to the Boiler. 2 To meet stringent requirements of the A.S.M.E. Code for high pressure power boilers careful selection, preparation and assembly of all plate material is mandatory. All joints are Fusion Welded by his- trained work men, X-Ray checked and test-specimen results recorded. Fusion Welded seams for the heavy flanged heads and tubular shell were adopted after thorough investiga tion and painstaking development of procedure con trolled by code and proved by exograph inspection. During the course of construction and after compiction each boiler is rigidly inspected by a qualified Inspector licensed by the National Board of Boiler and Pressure Vessel Inspectors to insure universal accept ability by any State or Municipality. Fusion Welded Joints are thoroughly annealed to in sure Relief of Locked-up Stresses by raising the tem perature of the bare Boiler and holding in a zone of 1200 F., then allowing to cool gradually. Our huge modern Recirculating-Type Stress Relieving Furnace, photo above, the only one of its size, insures a um/orrrnly of temperature of less than 100 variance throughout its entire interior. This procedure is iilallo important for absolute dependability, as well as ulti mate safety. 3 KEWAN HI-TEST Series HT Specifications-- BOILER NUMBER HORSEPOWER STEAM RADIATION--HANO FIRED -MECHANICALLY FIRED HEATING SURFACE GRATE AREA OR PLAN AREA FURNACE VOLUME FURNACE WIDTH LENGTH HEIGHT ABOVE GRATES CYLINDER DIAMETER FRONT REAR BOILER LENGTH OVERALL BOiLER HEIGHT FLOOR TO TOP OF SHELL WATER LINE HEIGHT STEAM SUPPLY SIZE BLOW-OFF SIZE FEEO WATER SIZE INJECTOR SUPPLY SIZE SAFETY VALVE BOILER OPENINGS NO -SIZE-- 125 LB VERIFY ALL SIZES - - 150 L8 BREECHING OIAMETER STACK DIAMETER STACK HEIGHT-HAND FIRED STACK HEIGHT-MECHANICALLY FIRED BREECHING OIAMETER. TWO BOILERS STACK DIAMETER. TWO 80ILERS STACK HEIGHT. TWO BOILERS. HANO FIRED STACK HEIGHT. TWO BOILERS. MECHANICALLY FIRED "`FIREBRICK ABOVE BASE LINE `"COMMON BRICK IN BASE AND PIER * "2 IN INSULATION LINING IN FURNACE OUTSIOE SURFACE TO COVER APPROX SHIPPING WEIGHT BOILER HANO-FIRED 125 LB '50 L3. MECHANICALLY-FIRED 125 LB 150 LB CODE WORD. STEAM BOILER-125 LB- W P. -150 LB . W P HT 50 HT 60 HT 75 HT 100 HT 125 HT 150 SO. FT. SO. FT. SO. FT. SQ. FT. CU. FT. 90 7000 asoo 500 18.3 72 60 3400 10200 600 20.3 90 75 10500 12750 750 22.5 105 100 14000 17000 1000 27.5 140 125 17500 21250 1250 30.2 181 150 21000 25500 1500 35.7 213 IN. 48 48 53 59 65 65 . in. ; 56 62 62 68 68 80 IN. . 40 46 46 50 60 60 IN.j 42 42 42 48 54 54 IN. | 66 : 66 72 78 84 84 FT. IN.| !N.I IN. 1 12-5 107 95 ' 13-5 113 101 14-3 116 104 15-5 128 111 16-2 142 124 18-6 142 124 IN. | 4 i 4 4 5 6 6 IN. 1 2I 2 2 2 24 24 IN. ivi 1l*2: n/s 1>/2 1i - "> IN i i i'i 1' * 14 14 IN. . 2-24: 2-24-2. 2-3 2-3 2-3 2-3 IN. . 2-24: 2-21/2, 2-3 2-3 2-3 2-3 IN. 24 26 29 31 33 36 IN, 22 24 27 29 31 34 FT. 55 60 65 70 75 30 FT. 45 50 55 60 65 70 IN. 31 34 38 41 44 48 IN. 29 32 36 38 41 45 FT. 1 65 70 75 80 35 90 FT. 55 60 65 70 75 80 NUMBER' NUMBER SQ. FT. ; SQ. FT. ' 1300 300 130 115 . 1450 850 155 145 1700 1100 165 165 2750 1450 205 200 3250 1500 235 250 3500 1550 260 300 L8. 13660 LB. 13760 LB. 12470 LB 12570 15380 15580 14080 14280 18870 19270 17405 17805 22920 23420 21070 21570 HTETF HTETG HTETH HTETI HTEFF HTEFG HTEFH HTEFI 26720 27420 24630 25330 HTETJ HTEFJ 30200 30900 23000 28700 HTETK HTEFK 'No Brickwork. Furnace Refractory or Insulation included. 'For Oil. Gas or Stoker, add word to code: example--ship one HTETF OIL. `Series 30 Nozzles for 250 lb. cast-iron or 300 lb. steel fittings. Steam supply and blow-off sizes given are openings regularly found on boilers in stock. EQUIPMENT--Standard--For Coal. Oil. Gas and Stoker--Boiler shell with Damper in Outlet; Flue Gas Chambers--Rear with insulation Lining, insulated Doors and Frames; Front with insulated Doors and Frame; Rear and Center Saddles; Fire Doors and Frames, Steel Casing extending to top of masonry base. Coal Hand Fired--Base Front with Ash Doors; Dead Plate; Stationary Grates. Oil. Gas, Stoker Fired--No Base Front furnished. Prices on Special Base Fronts at extra cost. FIRE TOOLS for Coal, Hand Fired --Hoe. Poker, Slice Bar, Flue Cleaners with handles. For Oil. Gas, Stoker--Flue Cleaners with handles only. ***No Brickwork. Furnace Refractory or Insulation included. TRIMMINGS-- for Coal, Stoker, Oil. Gas Steam Gauge with Syphon and Cock: extra heavy cast :rcn Water Column with Water Gauge and Gauge Cocks. Compression Try Cocks: Safety Valves as required by A.S.M.E. Code; Blow-off Valve and Cock: Globe and Check Valve for feed pipe. No other accessories or piping. Special trimmings furnished at additional cost. 4 Two-Pass Portable Tubular Boiler /or High Steam 0 V / BOILER NUMBER A-CYLINDER DIAMETER FRONT AR-CYLINOER diameter, rear 3-80ILER LENGTH C-BOILER HEIGHT D--WATER LINE HEIGHT E-WATER COLUMN HEIGHT F-5TEAM NOZZLE HEIGHT x^:yl;noer&-center to center G--FURNACE WIDTH H-pjRNACELENGTH J-FURNACE HEIGHT ABOVE GRATES K-3RIDGEWALL WIDTH L-FURNACE CASING HEIGHT ABOVE BASE M-STEAM SUPPLY LOCATION N-SAFETY VALVE LOCATION O-SAFETY VALVE LOCATION P-iNjECTOR STEAM SUPPLY LOCATION O-FEED WATER LOCATION R-9LOW-OFF LOCATION S-REAR FLUE GAS CHAMBER DEPTH '-FRONT FLUE GAS CHAMBER DEPTH TT -SHELL EXTENSION BEYOND CASING U-BREECHING CONNECTION. HEIGHT V- LENGTH W- WIDTH Y- LOCATION E-REAR FLUE DOOR CLEARANCE AA-FURNACE CASING WIDTH. INSIDE 0S- LENGTH CC-8ASE WIDTH 00- LENGTH EE- HEIGHT FF-SADDLE HEIGHT FRONT AND REAR GG-REAR BRICK PIER LOCATION HH-BASE REAR WALL THICKNESS 1 HT 50 HT 60 ; HT 75 HT 100 ! HT 125 ' HT 150 IN IN. ' FT IN, IN IN ! in : IN in. : 42 66 12-5 107 95 ' 93 113 81',: 42 66 13-5 113 101 99 119 8>/i 42 72 14-3 116 104 102 122 11N 46 78 15-5 126 111 109 132 1134 54 84 16-2 ; 142 ' 124 122 149 UN 54 84 i8-6 142 124 -V) 149 1H4 IN * IN. ; IN. IN 1 IN. 1 48 ` 56 . 40 ! 41/2, 71 : 48 62 46 4`,,i 77 53 62 46 9 79 59 65 65 68 68 30 50 60 60 999 67 100 100 IN 121 128 135 146 149 IN 53 : 54 54 54 60 IN ' IN. ! 10 , io ! 14 11 16 13 16 20 16 17 IN. i 34 39 42 43 45 IN. ; 32 | 32 32 34 36 63 16 26 45 36 N 1 20 ' 20 20 22 24 24 IN 20 20 20 22 24 24 1 N : 10 j 10 10 12 14 15 in ; 108 ; 114 117 127 143 143 IN, j 36 | 36 36 42 46 46 IN i 14 1 14 14 16 18 18 IN ' 9! 9 9 10 11 11 N 36 ; 36 39 42 45 45 IN. ; 70 : 70 75 90 96 96 IN. 64 70 70 76 76 38 IN 1 78 l 78 S3 98 104 104 IN. ' 90 96 101 107 107 119 IN. 15 ; 15 18 18 18 13 IN 26 32 26 30 40 40 IN 24 32 36 40 42 57 IN. 26 26 31 31 31 31 5 --A X Ray Inspection cf FusionWelded Seams on Hi-Tfil Boiler She!! by Radiograph.: Unit mounted on running gear. Tests X-RAY-RADIOGRAPH ANALYSIS: All seams subject to bursting stresses are radiographed on films which are filed for permanent record and future reference. By careful study of these films the inspector i? aided in determining the soundness of the weld. As a further check up on thoroughness of workmanship and physical properties the inspector subjects the test specimens to Tensile. Bend and Specific Gravity or Density tests. HYDROSTATIC TEST: The finished product is subjected to a Hydrostatic Test Pressure EQUAL to one and one-half times its Maximum allowable Working Pressure in accordance with the A.S.M.E. Code requirements. Each boiler is inspected during the course of con struction and tested by a qualified inspector of a recognized steam boiler inspection and insurance company. Desi gn The simplest possible shapes are used. Two cylindrical shells of different diameters are joined with tube heads by Fusion Welding, only a few diagonal head braces are needed. Front and rear flue gas chambers are an integral part of the boiler shell, eliminating joints. PLATE -- Shells and heads are fabricated from firebox and flange steel, 55,000 to 65.000 pounds per square inch tensile strength. Internal stresses are taken up without excess weight due to the cylindrical shape with no stay belts or cross braces. TUBES -- This new HI-TEST BOILER has High Quality Seam less Steel Tubes as standard equipment 4 ' direct and 3" return. The tube layout provides for free un restricted water circulation sweeping steam bubbles from the heat transmitting surface so a steadv water line is maintained. All tubes can be cleaned or removed from either the front or rear of the boiler. Conservative Rating In accord with accepted standards ten square feet of heating surface constitute one boiler horsepower. Heating surface, furnace volume, water content; Steam space, disengaging or liberating area all basic fundamentals, have been incorporated in technically correct ratio for good boiler design. Kewa..ee experience evolved through seventy-two years of research in steam generation predetermines the exact location of the steam nozzle which assures delivery of steam not less than 97% quality at high overloads without the necessity of dry pipes or baffles. 6 * X-RAY-RADIOGRAPH ANALYSIS: All seams subject to bursting stresses are radiographed on films which are filed for permanent record and future reference. By careful study of these films the inspector is aided in determining the soundness of the weld. As a further check up on thoroughness of workmanship and physical properties the inspector subjects the test specimens to Tensile, Bend and Specific Gravity or Density tests. HYDROSTATIC TEST: The finished product is subjected to a Hydrostatic Test Pressure EQUAL to one and one-half times its Maximum allowable Working Pressure in accordance with the A.S.M.E. Code requirements. Each boiler is inspected during the course of con struction and tested by a qualified inspector of a recognized steam boiler inspection and insurance company. Design The simplest possible shapes are used. Two cylindrical shells of different diameters are joined with tube heads by Fusion Welding, only a few diagonal head braces are needed. Front and rear flue gas chambers are an integral part of the boiler shell, eliminating joints. PLATE -- Shells and heads are fabricated from firebox and flange steel, 55,000 to 65,000 pounds per square inch tensile strength. Internal stresses are taken up without excess weight due to the cylindrical shape with no stay bolts or cross braces. TUBES -- This new HI-TEST BOILER has High Quality Seam less Steel Tubes as standard equipment 4 ' direct and 3' return. The tube layout provides for free un restricted water circulation sweeping steam bubbles from the heat transmitting surface so a steady water line is maintained. All tubes can be cleaned or removed from either the front or rear of the boiler. Conservative Rating In accord with accepted standards ten square feet of heating surface constitute one boiler horsepower. Heating surface, furnace volume, water content; Steam space, disengaging or liberating area all basic fundamentals, have been incorporated in technically correct ratio for good boiler design. Kewa..ee experience evolved through seventy two years of research in steam generation predetermines the exact location of the steam nozzle which assures delivery of steam not less than 97% quality at high overloads without the necessity of dry pipes or baffles 6 > J J KEWANEE, HI-TEST Series HT Furnace -- The available'furnace volume is large, and proportion tion. Handholes in front and rear heads are arge enough to permit removing tubes through them. ate to efficient combustion requirements. The heavy casing of reinforced steel panels is easily CASTINGS --The flue door, fire door and base -cnt assemblies are cast in extra strong fine grained qua'-y erected, and accommodates any commercial insulation iron to withstand the hard usage demanded m daily as well as refractory fire brick lining. This design insures permanence, reduces radiant heat losses to a service. Surfaces between doors and frames are machine ground to a gastight fit. minimum, and eliminates infiltration. More uniform ly effective furnace temperatures are maintained and high overall Combustion Efficiency is developed with lower operating and maintenance costs. Factors very DOORS Exposed to Temperatures are Heavily In sulated with material manufactured specially to meet KEWANEE specifications. important to all Power Plant Operators. Those scientific features are outlined briefly iu the ( The Rear Flue Gas Chamber diverting burned gases preceding few salient paragraphs in order to oresent of combustion out of the direct tubes into the return this KEWANEE HI-TEST BOILER as me'of the rubes is thoroughly well protected against radiant most outstandingly modern of its type. heat losses by means of high temperature-resistant factory-formed liners and insulated flue doors. ACCESSIBILITY for Cleaning and Inspection -- Ample cleanout handholes and manhole opening pro vided for easy periodic internal cleaning and inspec It is ready to serve every commercial or private de mand likely to arise in Industrial Plants. Laundries. Hospitals. Hotels. Creameries. Dairies. Food Product and Meat Packing Plants, Canneries. Chemical Plants, Railroad Shops, etc. o o Our Hi-Test cLelded line ships from the Kewanee factory expertly packed for quick assembly and setting on the masonry base all ready for the refractory lining of the Firebox casing. With brickwork reduced to a minimum these units arc readily transferable at nominal cost for rcinstallation should the necessity arise. 7