Document EqQ97gR8w07JeJRQ0666gea7n

TOWOLDMON0038666 WATER_PCB-00023135 TOWOLDMON0038667 WATER_PCB-00023136 Raw-Material Handling Bulk Delivery--For Major Cost Cutting Bulk-Shipping Service . Methods of Bulk Shipment Bulk-Storage Systems Materials of Construction Storage Tanks Pipe Lines Pumps and Filters Unloading Tank Cars Returning Empty Cars Unloading Tank Trucks Safety Precautions . Plasticizer Data Viscosity-Temperature Curves 2 2 2 4 4 5 6 10 10 11 12 12 12 14 15 ThJi bull*1/n rpf(Ki T.th-maJ Cv'ltf/n No. 0 49, "Th Bulk Tank Sfo-oo. o* Pla.<Lhn," S.p-.mh.. 1945. U6U58< 1 II II II TOWOLDMON0038668 WATER_PCB-00023137 RAW-MATERIAL HANDLING Handling of raw materials is an important part of any manufacturing company's operations. Materials handling accounts for about 25 per cent of labor time for in dustry as a whole. About 10 per cent of all hourly employees work full time on handling materials. Large-volume usage of chemical raw materials by the rubber and plastics industries provides many opportunities for important savings in bulk buying, receiving, handling, and storage. In this bulletin are outlined several ways by which significant economies can be realized in the purchase and handling of plasticizers. The contents of this bulletin include sections on Monsanto Chemical Com pany's delivery service, methods of bulk receipt and their advantages, technical details for a typical bulk-storage system, and properties of several Monsanto plas ticizers frequently shipped by bulk methods. BULK DELIVERY-FOR MAJOR COST CUTTING Receiving of Monsanto plasticizers by tank car or tank truck contributes to re duction of raw-material costs in three ways. First, bulk selling prices average about ten per cent less than carlot and trucklot prices. Savings are even greater in comparison with less-than-carlot delivery in drums. Lower freight rates add more savings on f.o.b. items. Other significant savings are made possible by re ductions in handling labor. MONSANTO'S BULK-SHIPPING SERVICE Nine bulk-storage stations, convenient to major plastics-producting centers, are maintained by Monsanto to service plasticizer customers. They are well kept, and care is taken to keep products free from all contaminants. Modem equipment and handling methods expedite shipments for fast delivery service. Both tank-car and tank-truck service are available from the bulk-storage stations located at the three plasticizer production plants at: Anniston, Alabama Everett, Massachusetts St. Louis, Missouri The following bulk stations serve customers by tank trucks with Monsanto plas ticizers: Akron, Ohio Long Beach, California Greensboro, North Carolina Miami, Florida Houston, Texas Perth Amboy, New Jersey Monsanto supplies a wide variety of quality plasticizers. Offering more than eighty plasticizers, Monsanto produces the largest selection of plasticizers in the world. The nearest Monsanto bulk station is a one-stop center for all your plasticizer needs. TOWOLDMON0038669 WATER_PCB-00023138 E VC s VoC <0 MONSANTO'S NINE PLASTICIZER BULK STATIONS The more frequently used plasticizers are generally stored at most bulk stations. Monsanto gladly works with customers to maintain convenient bulk storage of plasticizers, whenever the volume warrants it, to provide customers with the lowest cost and the most rapid service. tCzo3--rt oX 0*V1* <>8b 3 TOWOLDMON0038670 WATER_PCB-00023139 METHODS OF BULK SHIPMENT Liquid plasticizers can be delivered in bulk by railroad tank cars (from Annis ton, Everett, or St. Louis) or by tank trucks. Various factors determine whether rail or truck delivery is more practical and economical. Tank trucks are gaining rapid acceptance for bulk deliveries up to about 300 miles. Beyond that distance bulk deliveries are usually made by tank cars. Tank trucks are more versatile and flexible than tank cars. They do not require special railroad spurs. Frequently, faster delivery can be assured because the tank truck is a single unit, not dependent upon the schedules for an entire train of cars. When necessary, smaller quantities can be carried in tank trucks than in tank cars. Tank cars vary in capacity from a minimum of 4000 gallons to 10,000 gal lons, Tank trucks usually carry 3000 to 4000 gallons per shipment depending upon state highway regulations. Minimum tank-truck orders for 2000 gallons qualify for the tank-car price within established delivery zones. Both tank cars and tank trucks are available with two or three compartments for combined ship ment of two or three different plasticizers. In compartmented delivery, the Mon santo customer receives the bulk price on each plasticizer--a distinct advantage for small individual usage of several plasticizers. BULK-STORAGE SYSTEMS Suitable equipment must be available to permit receiving and storage of bulk plasticizer shipments. The larger the volume of single delivery, the larger is the storage equipment needed, and the larger the capital investment. On the other hand, as volume increases, so do the savings on handling. AKRON, OHIO TOWOLDMON0038671 WATER_PCB-00023140 Basic elements of a bulk-storage-and-handling system are one or more storage tanks, pipe lines, valves, a pump, and a filter. The number and size of (he stor age tanks depend on the volume of delivery, rate of plasticizer usage, deliv ery time, and distance from the Monsanto bulk station. Sufficient reserve capacity should be allowed for possible in-transit delivery delays. Details of construction and operation of bulk-storage-and-handling equipment are described in the next sections of this bulletin. The properties of Monsanto plasticizers typically shipped by bulk methods are also listed in detail at the end of the bulletin, These prop erties are helpful in design of the. stolage-and-handling facilities. Storage tanks are not always necessary for receiving liquid plasticizer by bulk shipment. If the bulk shipment can be used within a short time, a customer can supply the plant directly from the tank car, remaining on the siding. Rail roads allow two days to unload a tank car hut begin to charge demurrage after the second day unless the tank car is "trip-leased." If plasticizer usage is not quite large enough to warrant installation of storage facilities, a customer can also fill drums from the tank car or tank truck and thus realize the price saving from bulk delivery. MATERIALS OF CONSTRUCTION Corrosion problems arc ordinarily not encountered in the storage and handling # of plasticizers. Common steel is generally recommended for new storage facilities because of its lower cost. Existing equipment constructed of stainless steels, nickel, Monel, etc. are also suitable when available for conversion from other service. LONG BEACH, CAL. Uln ... 1 1^1 |u TOWOLDMON0038672 WATER PCB-00023141 STORAGE TANKS Constructon Vertical steel tanks of from 5000- to 25,000-gallon capacity, depending on stor age requirements, are recommended. Construction of a typical storage tank is illustrated by Figure 1. Plasticizer-resistant topping (epoxy, polyester, or furane) is recommended to protect the concrete slab against spilled plasticizer. The top is fitted with a 24-inch flanged manhole for inspection, four 2-inch flanged nozzles, and a 6-inch nozzle. One 2-ipch rtozzle is fitted with a 2-inch, iron-pipe goose neck for venting, and another is used as a charging inlet. The 2-inch charging line should be extended from the inlet nozzle to the bottom of the tank to prevent generation of static electricity by free-falling liquid. The other pair of 2-inch nozzles and the 6-inch one remain as spares. A 2-inch flanged nozzle is lo cated at the bottom of the tank for unloading. The unit is heated when necessary by external steam coils. The coils consist of '/'-inch copper or steel tubing installed in two sections. One spiral section on about 18-inch centers is placed directly against the bottom. The other is wrapped on 18-inch centers around the lower third of the unit. The coil area is then shielded and insulated with conducting compound as shown in Figure 1. Steam pressure on the coils can be up to about 110 pounds. (Steam coils may not be neces sary where extremely cold weather is unlikely or if rapid pumping during cold weather is not required. Storage tanks for polymeric plasticizers should be fitted with steam coils.) The tanks are equipped with a guarded, vertical ladder; a working platform with adequate guard rails is installed on the top of the unit (Figure 2). Additional devices, such as liquid-level gauges and temperature regulators, may be added if desirable. Horizontal, fuel-oil-storage tanks have proved satisfactory for smaller installa tions. Two 550-gallon tanks, such as the one shown in Figure 3, may be installed either above or below ground with common fill and outlet manifolds to handle a 1000-gallon tank-truck delivery. To prevent electrolytic deterioration of underground steel storage tanks the fol lowing procedure is suggested: Sandblast outside of tank. Apply coal tar-epoxy coating. Bolt or clamp a sacrificial zinc or aluminum anode (about 3 feet long and 8 to 10 inches in diameter) to lugs on each side of the tank. Such anodes reportedly last about 10 to 15 years. Back fill with sand and crushed gravel for good drainage. To prevent flotation of the empty tank, it should either be anchored or else covered by backfill heavy enough to exceed the buoyancy of the empty tank. Approximate installation costs of various storage systems are as follows: Capacity (gallons) Cost Installed ($) 1,100 (2--550-gal. tanks) 8,00 5,000 3,800 10,000 5,500 Capacity (gallons) 15,000 20,000 25,000 Cost Installed ($) 7,000 9.000 11,000 t # J) UtlHbdV | TOWOLDMON0038673 WATER_PCB-00023142 PLAN AT TOP 2" Outlet Nozzle ---------PLAN AT BOTTOM FIGURE 1--VERTICAL STORAGE TANK 7 TOWOLDMON0038674 WATER_PCB-00023143 18" 14" Radius Plan of Ladder Safety Guard Handrailing 0614591 TOWOLDMON0038675 WATER_PCB-00023144 * I ~T Manhole Optional 4- 10" -J 2" 2" Tappings >1 Bottom Outlet tor Abot/e Ground Storage 1 Dip-tube Outlet I ,, tor Underground Storage FIGURE 3--550-GALLON, 12-GAGE, FUEL OIL STORAGE TANK GREENSBORO, N. C. Preparation for Use Thorough initial cleaning of steel storage units is necessary. The inside is first sandblasted (unless it is essentially rust free) to assure clean and smooth sur faces. When this operation is completed, the sand is removed, and the tank is swabbed or mopped with the plasticizer to be stored. This step should be done as promptly as possible after sandblasting to prevent re-rusting, particularly under conditions of high humidity. After mopping, which removes most of the dirt, a few hundred pounds of the plasticizer is charged to the tank to complete the cleaning. By means of a pump, temporary filter, and hose, the plasticizer is pumped from the tank through the filter and sprayed through the manhole down the walls of the tank until all dirt is removed. 0614^92 9| TOWOLDMON0038676 WATER_PCB-00023145 PIPE LINES Recommended piping throughout the system is 2-inch steel with screwed unions. A suitable thread sealant is Permatex (trademark of the product manufactured by Permatex, Inc., Brooklyn, N.Y.). Welded pipe may be used instead of screwed connections, if periodic pipe changes are not anticipated. Heating of the lines when necessary is accomplished by tracing with a %-inch or Vfc-inch paralleled steam line. A typical run of steam-traced pipe is shown in Figure 4. Steel plug valves are used throughout the system. FIGURE 4--TYPICAL RUN OF STFAMTRACF D PIPE PUMPS AND FILTERS Self-priming, steel or bronze-lined, centrifugal pumps are recommended, though many type's of pumps may be used. Pumps such as Duriron Pump, Dayton, Ohio (Serif's H) or Worthington Pump, Harrison, New Jersey are satisfactory. The pump should be located and installed so that, it can both unload tank cars to the storage tanks and subsequently transfer the plasticizer from storage to pro duction units. A non-self-priming centrifugal pump may be used if the outlet nozzle is as close to the? bottom of the tank as piping will permit, and if the pump is not needed for top unloading of tank cars. Valves should be located on both sides of the pump to provide shut-offs necessary during repairs or repacking of the pump. Asbestos packings (Oarlock Inc.. Palmyra, N.Y.) have proved satisfactory in most instances. A cartridge filter should he installed on the discharge* sick* of the pump to remove' extraneous matter and dirt. A diagmmmafie piping arrang'em<*nt is suggested in Figure f>. 10 061<*593 | TOWOLDMON0038677 WATER_PCB-00023146 UNLOADING TANK CARS It is recommended that tank cars be unloaded by pumping out through a stand pipe placed through the dome opening. This method is preferred to bottom un loading to reduce the possibility of plasticizer leakage. Air pressure is not recom mended for unloading because of the possibility of car rupture or loss of product, by pipe? failure. Care should be exercised to prevent entry of moisture or other foreign matter into the car. The dome opening should be protected when the car is opened for sampling, final unloading, or at any other time. The following unloading procedure is recommended: 1. Spot the car, set brakes, and block wheels. 2. Open car vent pipe, and check to insure that the lines are not blocked. 3. Provide a protective covering, and then open the dome cover. 4. Place a 2-inch standpipe in the car, and connect to the suction side of the pump. [>. Operate valves to direct the plasticizer to the intended receiver, and pump out contents of car. 6. When car is empty, stop the pump, close all valves necessary, and disconnect and remove standpipe. In cold weather it may be necessary to warm the car contents before unloading. In suc-h instances (after step 3) steam at 30 to 100 pounds' pressure is passed through the heating coils of the car until the contents are heated to 30' C. The remainder of the above procedure is then followed. TOWOLDMON0038678 WATER_PCB-00023147 RETURNING EMPTY CARS After the standpipe has been removed, close the dome cover and all other connections securely. If the heating coils were used, remove all steam condensate by draining the coils and then blowing compressed air through them until dry. Do not permit water or other foreign matter to enter the car. UNLOADING TANK TRUCKS Tank trucks are usually unloaded by a gasoline-driven pump, with spark-proof ignition and a flexible hose connection, that is permanently installed on the truck. Care should be taken to prevent entry of moisture or foreign matter in the same manner as for tank cars. The unloading area must be free from flammable solvents that might be ignited by the truck-engine or pump-engine exhaust. The truck driver should follow this recommended procedure: 1. Spot the truck, set brakes, and block wheels. 2. Open dome cover, and check to insure that the lines are completely open. 3. Provide a protective covering while the dome cover is open for product sampling, inspection, and unloading, 4. Connect flexible unloading line to intended receiver. 5. Set valves correctly to direct the plasticizer to the intended receiver, and pump out contents. 6. When truck is empty, stop the pump, close all valves necessary, and disconnect. 7. Properly close dome openings to keep out foreign material on return trip. Heating of the truck contents is not normally required, since the product is loaded warm and since most trucks are insulated to maintain a sufficient temperature in transit. During cold weather, or when a viscous plasticizer is shipped, steam may be applied to the heating coils of the truck. SAFETY PRECAUTIONS Handling of plasticizers generally presents no serious safety hazards. Plasticizers are in general of low toxicity and do not give off appreciable vapors at temperatures ordinarily encountered in handling. However, before a tank that has contained a plasticizer is entered, it is advisable to blow clean, compressed air into the unit for a few hours. Workmen then entering the tank should wear an air mask as an added precaution. Although flash points of plasticizers are rather high, open flames should be kept away from and out of storage units or tank cars. If welding, for example, must be done in a unit, boil out with water containing about one-percent caustic soda, flush, and reboil with clear water. Air the unit again, and check the safety of the atmosphere inside the unit with an explosion meter before proceeding with welding. f i 0619995 ^ TOWOLDMON0038679 WATER_PCB-00023148 EVERETT, MASS. Plasticizers splashed into the eyes may be somewhat irritating, but no serious eye injuries have been reported. The standard first-aid treatment is immediate and copious washing with water for at least five minutes. If discomfort persists, a phy sician should be consulted. Plasticizer that gets on the skin should be washed of! with soap and water. They should not, of course, be taken internally. TOWOLDMON0038680 WATER_PCB-00023149 DATA ON MONSANTO PLASTICIZERS Specific Gravity Crystallizing Point Flash Point Viscosity Plasticizer Specific Gravity at250/25C Pour Point <C) Crystallizing Point <C) Flash Point Viscosity (Cleveland Open Cup) (Centistokes) CF) CC) @100F @210F PHTHALATES Dibutyl Diethyl Diisodecyl (DIDP) Diisooctyl (DIOP) Dimethyl Dioctyl (DOP) Santicizcr 160 Santicizer 165 Santiclzer 213 Santicizer 214 Santicizer 602 Santicizer 603 Santicizer 630 Santicizer 631 Santicizer 636 1.045 1.120 0.965 0.983 1.189 0.983 1.116 0.991 1.042 0.951 0.972 0.982 0.990 0.987 0.973 --51 --43 -45 --45 --51 --40 --45 below --35 below-- 0.3I --53 --45 0 (gel)--55 ' below --35 340 305 450 430 300 425 390 390 305 325 412 395 370 385 ADIPATES Diisodecyl (DIDA) Dioctyl (DOA) Di (n-octyl, n-decyl) (DNODA) Santicizer 644 0.919 0.927 0.916 0.922 below --50 below --70 ~- 5 below --50 425 377 401 395 PHOSPHATES Tricresyl Santicizer 140 Santicizer 141 GLYCOLLATES Santicizer B IG Santicizer [15 Santicizer M-17 1.162 1.208 1.090 1.097 1.180 1.220 --54 below --35 below - -35 ' 470 450 435 below --35 20 below --35 390 386 380 SULFONAMIDES Santicizer 8 1.190 0 345 P0LYMERICS Santicizer 405 Santicizer 407 Santicizer 409 SECONDARY HB-20 HB-40 Santicizer 216 AROCLOR PLASTICIZERS Aroclor 1221 Aroclor 1232 Aroclor 1242 Aroclor 1248 Aroclor 1254 1.129 1.084 1.082 0.966 1.006 0.874 1.187 1.275 1.386 1.410 1.500 --1 16 4 --54 --26 1 -35.5 -19 -7 10 ' 530 320 345 322" 286 305 348 _ 379 none t) Tague Closed Cup Santldrer, HB-20, HB-40, and Aroclor: Monsanto Chemical Co. trademarks. Registered in U S. Patent OUire 171 9.9 2.4 152 6.4 1.8 232 14 3.7 221 27.4 4.3 149 6.4 1.6 218 29 4.2 199 18 3.0 199 24.4 3.9 152 12.9 2.7 165 29.6 4.5 211 34.5 5.0 202 30.4 4.6 188 30.5 4.3 196 28.9 4.3 218 192 205 202 245 232 224 199 197 193 174 277 160 174 161" 141 15? 176 193 none 14.5 3.6 8.2 2.4 9.5 2.8 40 4.0 18 2.8 9.9 2.5 24 3.6 26 2.9 31 2.8 120 e 4800 2600 1294 310 180 122 9.5 2 1 29 3.8 4.6 68 17 4? 470 2.4 3.1 6.0 C6l<af>97 TOWOLDMON0038681 WATER_PCB-00023150 -<a ' ''I sg g?g* m m isigggg gg s - i i-- TEMPERATURE. Degrees Fahrenheit FIG. 6 -- PHTHALATFS (A) -- VISCOSITY-TEMPERATURE CHART A.S.T.M. Standard Viscosity-Temperature Chart (D341) Ot TEMPERATURE, Deg-ees Fahrenheit FIG. 7-- PHTHALATES <B) -- VISCOSITY-TEMPERATURE CHART A.S.T.M. Standard Viscosity-Temperature Chart (D 341) 0ol^596 TOWOLDMON0038682 WATER_PCB-00023151 r # TEMPERATURE. Degrees Fahrenheit FIG. 8-- PHTHALATES (C) -- VISCOSITY-TEMPERATURE CHART A.S.T.M. Standard Viscosity-Temperature Chart (D 341) TEMPERATURE. Degrees Fahrenheit FIG. 9 -- ADIPATES -- VISCOSITY-TEMPERATURE CHART A.S.T.M. Standard Viscosity-Temperature Chart (D 341) Ofel^oOC TOWOLDMON0038684 WATER_PCB-00023153 TEMPERATURE. Degress fehuen'ie.t FIG. 10--PHOSPHATES -- VISCOSITY-TEMPERATURE CHART A.S.T.M. Standard Viscosity-Temperature Chart (D 341-39) Modified TEMPERATURE. Degr Fahrenheit FIG. 11--GLYCOLLATES -- VISCOSITY-TEMPERATURE CHART A.S.T.M. Standard Viscosity-Temperature Chart (D 341-39) Modified Ob i^toO 1 TOWOLDMON0038685 WATER_PCB-00023154 SANT1CIZER 40/ * TEMPERATURE. Degrees Fahrenheit FIG. 12 -- POLYMERICS-- VISCOSITY-TEMPERATURE CHART A.S.T.M. Standard Viscosity-Temperature Chart (D 341) lEMPEKAOlKE, Degrees Fahrenheit FIG. 13--SECONDARY PLASTICIZERS--VISCOSITY-TEMPERATURE CHART A.S.T.M. Standard Viscosity-Temperature Chart (D341) Obi'.bOi TOWOLDMON0038686 WATER_PCB-00023155 NoJ KINEMATIC VISCOSITY, TEMPERATURE. Degrees Fahrenheit FIG. 14--AROCLOR PLASTICIZERS -- VISCOSITY-TEMPERATURE CHART A.S.T.M. Standard Viscosity-Temperature Chart (D341) c 30 SC 50 70 80 90 IDO no 12D 130 1 40 ISO ISO 170 180 190 200 210 TEMPERATURE. Degree* Fahrenheit FIG. 15 --SULFONAMIDE --VISCOSITY-TEMPERATURE CHART A.S.T.M. Standard Viscosity-Temperature Chart (0 341) Cfe 1 6 C 3 TOWOLDMON0038687 WATER_PCB-00023156 The information contained in this bulletin is to our best knowledge, true and accurate, but all recommendations or suggestions are made without guarantee, since the conditions of use are beyond our control. The Monsanto Chemical Company disclaims any liability incurred in connection with the use of these data or suggestions. Furthermore, nothing contained herein shall be construed as a recommendation to use any product in conflict with exist ing patents covering any materia) or its use. 061461K TOWOLDMON0038688 WATER_PCB-00023157 AKRON AUANTA BOSTON CHIC AGO UNC NN AT I CLEVELAND DETROIT HOUSTON LOS ANGELES MINNEAPOLIS MW YORK PITTSBURGH SAN FRANCISCO SEATTLE . SYRACUSE WILMINGTON MONSANTO CHEMICALS LTD. London MONSANTO CHEMICALS (AUSTRALIA) LTD, Melbourne MONSANTO (CANADA) LTD. Monirepl Toronto * Voncouver / VI U614605 TOWOLDMON0038689 WATER_PCB-00023158