Document EqOam2xm8VbNDvE3kzz1YBNKV

INTERNAL CORRESPONDENCE UNION CARBIDE CORPORATION TECHNICAL CENTER P.O. BOX 83GL SOUTH CHARLESTON, WV 00003 T;) tN D-s-.sS H. E. Rucker 512/2009 Codv 8. H. Avashia, M.D. - 512/23 J. W. Barna - 2009/6 W. L. Browning - 2009 W. V. Filipek - 5515 C. P. Maxwell - 701/2 B. R. McMakin - 2009 J. H. Parsons - 2281 W. J. Vincent - 514/109 March 19, 1987 EM&TS - HS&EA Industrial Hygiene Asbestos Exposure Monitoring Attached are the results of the Asbestos exposure monitoring performed on insulators in the South Charleston Plant, Building 106- They were monitored over a 3 day period while using glove bags to remove asbestos from several lines, horizontal and vertical. Employees were equipped with 2 pair of coveralls, no street clothes, boots, gloves, head cover and either an A0R57A or Willson R12 Half-face, HEPA filter, respirator. The employees showered each day, before leaving the plant. The monitoring results indicate that the exposure levels were well below the 0.1 fiber/cc Action Level, established by OSHA for an 8-hour workday (TWAg). We feel that the glove bag method is a very good way of controlling airborne fibers. However, we must be sure that the procedure is followed closely by each insulator using a Glove Bag. Please inform J. R. Chandler, R. E. Coyner and S. M. Barker of their exposure monitoring results, as soon as possible. Have them sign and date this report and return to M. A. Patel at Building 701-330. UCC 024802 Asbestos Exposure Monitoring -2- March 19, 1987 If you have any questions or if we can be of further assistance, please feel free to call us on extension 4779 or 3750. WORK BY: APPROVED BY: Jt .&JJ Manhar A. Patel VES:MAP:rab 2180P UCC 024803 I ASBESTOS EXPOSURE MDNIT0RIN3 Carp. Ref. W2158 K2160 W2161 Date 3-11-87 3-12-87 3-12-87 3-12-87 3-13-87 Sanple Type/ Enployee Name Sarrpling Time Personal/ J. R. Chandler 6hrs 57min Air Cone, fibers/cc 0.0314 TViAg fibers/cc 0.0273 COMMENTS Collected while stripping, along with 2 others, 40 feet of asbestos using glove bags. Personal/ R. E. Coyner 7hrs 26min 0.034 0.0317 Collected while using glove bags to strip approx. 50 feet of asbestos, with 1 other insulator. Personal/ S. M. Barker 7hrs 15min 0.0571 0.0531 Collected while using glove bags to strip approx. 50 feet of asbestos, with 1 other insulator. Personal/ J. R. Chandler 7hrs 15min 0.0066 Personal/ S. M. Barker 7hrs 9nin 0.041 0.00698 0.0366 Collected while retrieving bags and helping with vacuun - ground man. Collected while stripping approx. 12 feet of asbestos using glove bags. Opened vacuum cleaner to change HEPA filter had a few problens. ASBESTOS Permissible Exposure Level TWg 0.2 fibers/cc OSHA Action Level 0.1 fibers/cc 2180P rab UCC 024804