Document EqMOR0Ka7QmoGmJzRXKoEQxOR
EPA Inspection Report - Page 1 of 5
Region 6 - Enforcement & Compliance Assurance Division
INSPECTION REPORT
Inspection Date(s): Media Program: Regulatory Program(s)
02/12/2024 Air Title V, NSPS, SIP
Company Name: Facility Name: Facility Physical Location:
(city, state, zip code) Mailing address:
(city, state, zip code) County/Parish: Facility Phone Number Facility Contact:
Motiva Enterprises LLC Port Neches Terminal 100 E Port Neches Ave Port Neches, TX 77651 100 E Port Neches Ave Port Neches, TX 77651 Jefferson County 409-835-5381 Blake Yarbrough blake.yarbrough@motiva.com
Complex Manager
FRS Number: Identification/Permit Number: Media Identifier Number: NAICS: SIC:
110000599576 RN100210103 / FOP O3277 AFS # 48-245-00013 424710 5171
Personnel participating in inspection:
James Haynes
EPA Region 6 ECDAT
Ben Rosenthal
EPA Region 6 ECDAT
Blake Yarbrough
Motiva Enterprises LLC
Michael Brinkley
Motiva Enterprises LLC
Arles Zelayn
Motiva Enterprises LLC
Physical Scientist Physical Scientist Complex Manager Terminal Manager Operator
EPA Lead Inspector Signature/Date
Haynes, James Date: 2024.03.28 13:13:27 -05'00' Digitally signed by Haynes, James
James Haynes
Date
Supervisor Signature/Date
Digitally signed by JAMES
JAMES LEATHERS LEATHERS Date: 2024.04.15 17:44:20 -05'00'
James Leathers
Date
6ENFORM-019-R8.2 (02/12/2020)
1
EPA Inspection Report - Page 2 of 5
Section I - INTRODUCTION
Motiva Enterprises LLC / Port Neches Terminal Inspection Date 02/12/2024
PURPOSE OF THE INSPECTION
I, James Haynes, with Ben Rosenthal, EPA Region 6 inspectors, arrived at Motiva Enterprises LLC's Port Neches Terminal (the "Facility") at 16:00 on February 12, 2024, for an unannounced inspection. We met with Mr. Michael Brinkley, Terminal Manager, and Mr. Blake Yarbrough, Complex Manager. I presented my inspector credentials to Mr. Brinkley and informed him that this was an EPA inspection to evaluate the Facility's compliance with the Clean Air Act ("CAA"). The scope of the inspection is a partial evaluation ("PCE"). This inspection occurred as part of a multi-scale monitoring project in the BeaumontPort Arthur area. Photographs taken during the inspection can be found in Appendix 1.
FACILITY DESCRIPTION
The Port Neches Terminal is used for the storage and distribution of crude oil and other petroleum products.
Section II - OBSERVATIONS
During the opening conference, we discussed the Facility's in-service internal floating roof ("IFR") and external floating roof ("EFR") storage vessels and marine loading operations. We informed the Facility that we would use a FLIR GF620, an optical gas imaging ("OGI") camera, and TVA 2020, a flame ionization detector ("FID"), as part of the inspection.
We met with Arles Zelayn, an operator at the Facility, to begin our site tour. The following table is a summary of our observations:
Tank # 280 34030
1815
Tank Contents
Design
Notes and Observations
Stormwater
IFR
No hydrocarbons emission observed with the
OGI camera.
Debutanized Aromatic EFR
EPA inspectors noted hydrocarbon odors at
Concentrate
the tank's platform and along the circumference of the tank's shell.
EPA inspectors noted visual defects of gasket
material of the tank's guidepole hatch (Photo
1) and measured a concentration of 3,300
parts per million using the FID. [AOC 1] Light hydrocarbon emission observed with
the OGI camera at the base of the secondary
rim seal. [AOC 2]
Cyclohexane
IFR
No liquids on the floating roof.
No hydrocarbon emissions observed with the
OGI camera.
2
EPA Inspection Report - Page 3 of 5
1835 1834 275
Crude Oil Crude Oil Crude Oil
Section III - AREAS OF CONCERN
Motiva Enterprises LLC / Port Neches Terminal Inspection Date 02/12/2024
EFR
Hydrocarbon emission observed with the OGI
camera along the rim seal. [AOC 2]
EFR
No hydrocarbon emissions observed with the
OGI camera.
EFR
Hydrocarbon emissions observed with the
OGI camera along the rim seal. [AOC 2]
I conducted a closing conference at 18:45 for the inspection with Mr. Yarborough and Mr. Brinkley. We summarized the observations, including the following Areas of Concern:
1) At Tank 34030, upon detecting hydrocarbon odors at the tank's platform, we observed the gasket material at the guidepole hatch was torn. Mr. Rosenthal also measured emissions with the FID and confirmed that emissions were emanating from the hatch near the torn gasket.
2) At Tanks 34030, 1835, and 275, we observed hydrocarbon emissions with the OGI camera along the rim seals indicating that the secondary seals may not be controlling emissions as required.
Section IV - FOLLOW UP
EPA requested additional information following the inspection. On March 11, 2024, Motiva Enterprises LLC submitted responses to my request.
Section V - LIST OF APPENDICES
Appendix 1 - Photograph Log
3
EPA Inspection Report - Page 4 of 5
Motiva Enterprises LLC / Port Neches Terminal Inspection Date 02/12/2024
Appendix 1 Photograph Log
EPA Inspection Report - Page 5 of 5
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY
Photograph Log
Photo No. 1
Location: Motiva Enterprises LLC / Port Neches Terminal
City: Port Neches
County: Jefferson
State: TX
Photo File Name: Date of Photo: Time of Photo: Photographer: Description:
FLIR0033.jpg 02/12/2024 17:21 James Haynes Torn gasket material at hatch on Tank 34030. EPA recorded approximately 3,300 parts per million VOC, as methane, with the FID.