Document EqEV3KneoaOok2M9bkve4xwwn

MQNS PROCESS DESCRIPTION FOR THE MANUFACTURE OF AROCLORS MONSANTO COMPANY Monsanto, Illinois Messrs: P. P. Hcislcr H. C. Carder M. K. Gibbs - Oi^g. Res. II, 1,. Hubbard - Org. Res. Process Holders September 20, 1966 Tentative Amendment No. "K" TI'JHK Tentative Amendment No. MFH to the Standard Manufacturing Process for Aroclor (Dept. 246 - WGK) dated 7/20/64. ODJKCTJVK Produce improved quality Aroclor with activated bauxite (A12Oj) treatment . PKFSKNT FRACTION Distilled Aroclor is treated with activated attapulgus clay for quality up-grading in one of two earth treating tanks followed by filtration to remove suspended solids before storage. PROPOSK1J PKpCf:DUKK Substitute clay with "poroccl", activated bauxite supplied by Minerals and Chemical Corp. , at levels sufficient to evaluate up-grading per formance. Poroccl (20/60 and 4 60 mesh) suspended with agitation and recirculation in the existing earth treating system. Treated Aroclor will be filtered to remove suspended solids before storage. JUS'i'IKlCAlTO^N ' Anniston personnel have demonstrated (sec Report 370- 322-9 byJ.G. Bryant) exceptional up-grading performance in the laboratory by circulating Aroclor 1242 through a packed bauxite bed. Reported per formance is summarized below: Specification Present Up-grading Performance @ Anniston........ ..... Bauxite l*b. Treating Pcrformanc e Resistivity (x 10%mm-cm) Power Factor () lOO^C 8* 1 KC <6? 1 00*C & 60 cps Tbcrm.tl Chemical Chlorides, ppm Wcstinghousc Stability, ppm Hydrolysis Stability, ppm 900 0. 2 2. 0 0. 3 0.7 0.2 44.000 0. 02 * 0. 03 * 0.07 0.18 0. 04 * Kxcecding Sensitivity of Measuring Instrument. HONS 047761 2 JUS'J JKICATION (Conl'd. ) Monsanto can very economically defend its unique marketing position if such performance can be demonstrated on a plant scale. TIMING This amendment will be initiated after Anniston has successfully demonstrated a similar amendment and at time consistent with normal production schedules, SAJ-KTV Aluminum oxides have been in contact with Aroclors for more than two years in storage units with no difficulties. Because of this, and laboratory work with bauxite treatment, present safety considerations are believed to be adequate. KXTKNT Op l>?.-MONSTRATipN. Up to 40 batches of Aroclor 1242 (2, 000 gal. /batch) will be processed resulting in a maximum of 800, 000 lbs. of product which will be used in non-electrical applications. Prepared by: Cliff Woodward Reviewed By: Approved By: ^ ___ ......................................................................./O'U-66 J)iv, Rcsca rch Group Deader Date Production Supervisor Date ^ L /rv.:- A /ci,- .. /o/,.uc Mgr. of Research ' J Prod. Gen. Superintendent Date Research Safely Review Committee $ 0 0/v\n . Tut/ ! /of/g/H, PI. Process Res. Grc$p Lcador'Dale y?5 Gen. .... Tech. Servicing Dale i /> / > ../' /Djf-Sfa Technical Production Manager "Date HONS 047762 MONSANTO COMPANY ORGANIC CHEMICALS DIVISION STANDARD MANUFACTURING PROCKSS FOR AROCLORS - DEPARTMENT 246 Supersedes: Standard Manufacturing Process for the Manufacture of Aroclors, Department 246 Dated July 20, 1964 and all amendments. Trcpared by: D. E. Harris Approved by: _S "General Superintendent fiesearch ^cTrhfca^^o^ci3on' \FecTm Date: /o/t,k af COPY in of This process is the property of Monsanto Company and the recipient Is responsible for its safekeeping. It contains confidential Information of Monsanto Company which must not be reproduced, revealed to unauthorized persons or sent outside the company without proper authorization. Either retain in a secure file or return to the Standard Documents Dept. HONS 047763 ( DJ STRIBUTION SHEET 1. Technical Information Center 2. Technical Information Center 3. Central Reports f|, Technical Production Manager i). Production General Superintendent 6. production Supervisor 7. TS1) Group leader 8. Plant Research 9. Id brary 10. Extra 11. Extra 1?. Extra 13. Extra 3 It. Danna 13. Danna ( HONS 047764 AMKNDING RECORD SHKKT MONS 047765 ( TABIK OK CONTENTS INDEX SECTION I SYNOPSIS OK PROCESS SECT]ON 13 F1.0W SHEETS A CHICHINATION REACTION STEP B. AERATION AND D1STIIJ.AT10N 0. B).ENDING, FILTRATION AND STORAGE SECTION 111 PROCESS IN DETAIL A. NOMENCIATURE AND BATCH DATA B. CHI.ORINAT] ON REACTION STEP C. AERATION AND DIST1LIAT10N D. BI.END1NO, FILTRATION AND STORAGE E. BY-PRODUCT HYDROGEN CHIORIDE Section iv { APPENDIX A comments on process A. CHLORINATION STEP B. AERATION & DISTILLATION C. BLENDING & FILTRATION D. GENERAL EQUIPMENT LIST APPENDIX B FINISHED GOODS AND RAW MATER]All SPECIFICATIONS APPJiNDIX C PHYSI CAL AND CHEM] CAI, DATA APPEND!X D UTILITIES APPENDIX E PERSONNEL APPENDIX F PACKAGING AND SHIPPING APPENDIX Q APPENDIX H MATER] AI, BAIANCE ATMOSPHERIC DISCHARGE AND WASTE DISPOSAL APPKND1X I APPENDIX J PROCESS CONTROL PROCEDURES SAFETY AND TOXICITY DATA APPEND!X K BACKGROUND INFORMATION APPENDIX I, time: cycles APPENDIX M QUALITY CONSIDERATIONS APPENDIX N MI SCELLANKOUS HONS 047766 PAGK ? 3 3A 3H 3C U 5 -6 7 7-8 8 9-13 II 1? 13-21 ??' 23 ?3|-?0 29-30 31-3? 33-33 36 37 38-3)3) 3)9 H6 3)7-93 53)-57 ( llcpt. ?^6 - Frocess poser! ptl on i. AHOCljOH SKCT1 ON 3 SYNOFSJS OP PROCESS Aroclor 1e a trade name used to designate chlorination products of biphenyl, biphenyl high boilers, or mixtures of the two. liquid Aroclors are produced by chlorinating biphenyl to 21, 32, k?, h0, 6*1, 60, and 62<f> chlorine content. Chlorination above 63St yields a solid product at norma] temperatures. Liquid Aroclors are Identified by four digit numbers; The last two digit numbers represent the chlorine content (percentage by weight), and the first two numbers represent the Aroclor condition (crude or distilled). Crude Aroclors start with the prefix 11 whereas distilled Aroclors start with the prefix 12. For example, Aroclor 121)2 Is a distilled chlorinated Diphenyl containing 1)2JS chlorine. The first process step In tte manufacture of AroclorB Is a chlorina tion reaction. Biphenyl ( 0-0) and chlorine (Cl?) gas In.the presence of a Ferric Chloride (FeClj) catalyst are reacted to form a chlorinated aromatic compound. Hydrogen chloride (HC1) gas Is liberated during this reaction and piped to the muriatic acid department. The exact chemistry of biphenyl chlorination Is unknown. Many Isomers are formed. A schematic represcntatlon of biphenyl chlorination Is as follows; B1IHKNYI. M.W. * 15*1 CH1.0R1 NB M.W. * 71 AR0C1.0H M.W .= (26*1.1396.6) HYDHOGKN CHLOHIPK M.W.-; 36.6 HONS 047767 Dept. 246 - Process Description AROCl.OR SKCT'3 01l_l SYNOPSIS .OKJWtOCKSS (Cont'd.) The second prooess step 1b the aeration and distillation of the crude Aroclor. Dry air Is blown through the crude Aroclor for a period of two hours or more. Aeration removes most of the free hydrogen chloride. Distillation of crude AroclorB 1b done under vacuum auto matically controlled with the controller pre-set between 30-50 mm Hg. age. to obtain the best performance. Distillation of crude Aroclor separates residue, lime, ferric chloride, and tars from the finished product. The third.process step Includes blending, filtration, and storage of AroclorB. Approximately 0.1 - 0.2# by weight of Attapulgus earth Is added to the distilled Aroclor. The mixture Is agitated and filtered to the finished product tank. The purpose of the Attapulgus earth ., Is to absorb moisture and chloride Ion to Improve the electrical properties of the Aroclor. During the filtration of distilled Aroclor, 2 - 16 or,, samples of the finished product are taken to the laboratory for control analyses. If the control analyses pass specifications, the batoh is transferred to a storage tank. This process description will describe the production of Aroclors 1242, 1248, 1254, 1260, 1254 xylene mix, and 1262. MOMS 047768 Dept. ?i|6 - Process Description AHOCipjl SKCT1 ON_ 1_1 FLOW SHKKTS Thl B section contains the following flow sheets. 1. Complete process flow sheet. 2. Chlorination Reaction Step 3. Aeration and Distillation li. Mending, Filtration and Storage. I 3. < MOWS 047769 MONS 0 4 7 7 7 1 MOMS 0 4 7 7 7 2 Dept. 246 - Process Description 11. AHOCIOR SUCTION111 PKOCKSS IN DKTA) 1. A. NOMKNCLATUHK AND HATCH DATA Aroclor 3s a trade name used to designate chlorlnatjon products or biphenyl, biphenyl high boilerB, or a mixture of the two. The physi cal properties vary from light free flowing liquids to crystalline and non-crystalline solids, depending upon the degree of chlorina tion and the composition of the raw materials. Chlorinated biphenyl yields a liquid product of Increasing viscosity up to and Including 6356 chlorine. Chlorination above 63# yields a Bolld product at norma 1 tempera ture s. A numerical system of nomenclature, consisting of four digits, has boon developed for Identifying the various Aroclors. The first digit denotes the aromatic raw material used In the chlorination step. The figure 1 -- Indicates 100# technical grade biphenyl. The second digit denotes whether or not the product Is distilled. The figure -1 -- Indicates undl stilled product, and the figure -2 - Indicates a distilled product. The last two digits of the nomen clature Bystem denote the approximate percentage by weight of chlorine contained In the finished product. For example, Aroclor 1242 1b a distilled chlorinated biphenyl containing *12# chlorine. Manufacture of all liquid Aroclors Is essentially the same. Hat-h data arc listed below: TyP0 Aroclor Diphenyl Charge 1242 4000// 1248 4000// 1254 4000// 1?60 AOOOJ/ 1262 4 000// Chlorination Time 6 Hrs. 8 Hrs. 10 Hrs. Hrs. 14 Hrs. Specific Gravity of Crude 1.349-58 1.4o8- 18 1.498-508 1.558-69 1 .580-90 at 65C at 630 C at 65C at 90C at 90C Weight of Crude Hatch 6670//-. 7580// 8450// 9600// 10,600// Weight of Distilled Hatch 6400// 7200// 804 0// 9100// 9850// Tons of 100# by-product 1IC1 per Hatch 1.24 1.43 2.27 2.47 2.70 Thcoretl ca] Molecular Weight 257.7 292:6 326.6 369.5 395.6 MONS 047773 K Jk'pt. ?HG - process Doscript!on b. AKOCJOK SECTION 333 HtOCKSS IN DKTA1 1. it. cuwia nation rjsacm on stop Chlorination of biphenyl is the only process step where a chemical reaction takes place. All other Aroclor process operations are mechanical. The starting raw materials for Aroclor production are biphenyl and chlorine gas. Hi phenyl is received in 8,OOQ 10,000, and 20,000 gallon tank cars from Anniston, Alabama. The biphenyl in the tank cars 1b a solid mass because the crystallising point of biphenyl is 68.7C. Steam must be applied to the tank car coils to melt the biphenyl. It is necessary to melt a vent hole through the solid mass of biphenyl by insertion of a hairpin steam coil through the tank car dome before applying steam to the tank car coils. The vent hole avoids a press ure build-up in the bottom of the tank oar and possible damage to the car. When the biphenyl is completely melted, it is sampled for ( identification and unloaded through the tank car standpipe by air pressure to the 2b,000 gallon storage tank. Dry air is used to unload the biphenyl cars to keep the biphenyl free from moisture. The flash point of biphenyl Is 112c. Chlorine gas is received in a 1) inch pipeline from the chlorine department. In order to facilitate operation of the chlorine liquefaction system, "snift" gas with a purity of 75-93^ (the remain der being air) is transferred from the chlorine department. The normal pressure of the chlorine gas in Department 2k6 is 20-23 psig. Hi phenyl (AOOO))1) is charged into each chlorlnator from the measuring tank. The biphenyl charge in the measuring tank can be regulated by valves at different overflow levels. The four overflow levels on the measuring tank permit biphenyl charges of 1800, 2800, 3600, and 1)000 pounds. TWO pounds of anhydrous ferric chloride are charged to the chlorlnators after the biphenyl is charged. MONS 0<*77?4 Chlorination is carried out in five chlorlnators. Each chlorlnator is three feet in diameter by sixteen feet high, and constructed of steel. Pour of the chlorlnators has a catalyst bed which is 2'3" in diameter by 8 feet high. The catalyst bed consists of 1-1/2 inch diameter by 2 inches long pieces of pipe which are similar in nature to raschig rings. The fifth chlorlnator is identical to the other chlorlnators except that it has no catalyst basket. The catalyst beds in four of the chlorlnators will be removed as they fail mechanically. After charging the chlorlnator, circulation of the charge is started before the chlorine feed is begun to maintain an even distribution of the ferric chloride catalyst. The temperature of the biphenyl is 1]0C-120C at the Btart of the chlorination. The chlorlnator mass reaches 120C-130C within 30 minutes after the biphenyl is charged. Dept. ?'l6 - JTocess Description AUOCIOU c. SKCT1ON 1J 1 HtOCKSS JN DKTA3L. (Cont'd.) D. Chlorine gas from the chlorine department passes through a brink mlBt eliminator and evaporator before entering the ehlorlnator. The mist eliminator removes most of the Impurities, and the evapora tor Insures that all of the chlorine Is gaseous. ' The purified chlorine gas Is admitted to the bottom of the chlorlnator through a distributor plate (Bparger) and passes through the catalyst bed. A ehlorlnator temperature less than Y/0C Is main tained during the chlorination reaction to avoid sublimation arid subsequent condensation of biphenyl In the off-gas system. Knch ehlorlnator Is equipped with a Brink mist eliminator. The purpose of the off-gas mist eliminators Is to trap entrained particles of Aroclor and biphenyl. The chlorination temperature In the ohlorlnators 1b controlled by automatic control of the air flow through the externa] alr-coolcd heat exchanger. The chlorination temperature must be at least 1?0C 30 minutes after the Btart of the batch and no more than 170 C to finish off a batch. The normal batch temperature Is 130C. The louvers of the air-cooled heat exchanger located In the externa] circulating line of the ehlorlnator are controlled such that the batch temperature will remain between 120C and 170C. The temperature of the batch Is recorded at four different points: (1) In the center of the ehlorlnator, (2) Just above the chlorine sparger In the ehlorlnator, (3) at the discharge of the ehlorlnator pump, and {) at the discharge of the air-cooled heat exchanger, point 1 1b alarmed for high temperatures, and point l| as alarmed fol low temperatures. As a safety device, a high temperature sensing element Is positioned at point 2 to shut off the chlorine gas flow If the reaction temperature exceeds 190C. The batches are continuously circulated at ari average flow rate of 200-220 0PM from the bottom of the ehlorlnator, up through the air cooled heat exchanger, and back Into the top of the ehlorlnator over the catalyBt bed. Chlorine feed up to a maximum of 1500 pounds per hour Is fed Into each ehlorlnator through a flow recorder-integrator which is alarmed. Progress of the chlorination reaction Is cheeked periodically as needed after 80j chlorination as measured by the recorder-inte grator. The degree of chlorination 1b measured by determining the specific gravity of a sample taken from the circulating line. More frequent gravity cheeks are made when approaching the end of chlorination. MONS 047775 Dept. 2Jl6 - Process Description ' AHOCJOR SKC'J'3 ON 322 22<_ockr.r_ 3 n_ dktaii . C AKHAT3 CM) AN1) D3ST3 1JAT3 0N When chlorination is complete, the crude Aroclor is pumped into number two blow tank (capacity 2000 gallons). The crude Aroclor is aerated in the $2 blow tank for two hours or more with dry air. Aeration of crude Aroclor removes most of the free hydrogen chloride. Crude aerated Aroclor is transferred from the #2 blow tank to the //I blow tank. The #1 blow tank is used as a crude Aroclor feed tank to the stills. Crude aerated Aroolor is transferred from the //I blow tank to vacuum stillB through an automatic control valve which maintains a constant level in the stills. Under normal conditions the automatic feed to the stills is shut off after distilling bout 75,000 pounds of Aroclor. (This is equivalent to filling 7 still receivers). The Btill is then boiled down until a temperature difference between the still coil outlet and vapor temperature , approaches 40C. At this point distillation is discontinued and ' all but a small heel of the residue is drawn off to drums and discarded or Bold as Montar. The still is immediately recharged with crude Aroclor and 200 poundB of lime is added directly to the still pot. Hydrated lime is received in 50 pound bags. The lime neutraliz es any residual HC1 in the still liquor and prevents sublimation of ferric ohloride during the distillation period. Distillation of Aroclops is done under vacuum automatically controlled. The best performance is obtained at a steady vacuum which can be pre-set. by a controller between 30-50 mm Hg. Abs. Natural gas is used to heat the coil of the Aroclor still furnaces. The pressure of the gas.burner (eclipse, st. 108.5, 2", //5G8, GOO,000 BTU/hr.) is adjusted as needed for production requirements. The norma] gas pressure Js 3-5 psig. p. Hl.KNl)lNa, P'31.THAT] CM, AND STORAQK ' When the still receiver is filled, the distilled Aroclor is pumped to the blend tank (2000 gallon capacity). After two fillings of the receiver tank have been pumped to the blend tank, approximately 0 pounds of attapulgus earth 3b added to the distilled 121)2 Aro:lor. All other Aroclors are earth-treated with 20 pounds or Attapulgus earth. Regular AttapulguB earth is received in 50 pound bags. The mixture is agitated and filtered to the finished product tank (2000 gallon capacity) through a 3G inch stainless steel Sparkler kilter. ( The attapulgus earth 1b roasted at 250C for a minimum of four hours in a Orieve-Hcndry drying oven before addition to the Mend tank. The purpose of earth heat treatment is to remove any moisture in the earth and activate it. The attapulgus earth absorbs water and ionic impurities. This improves the electrioal-auali ty properties of the Aroclor. . HONS 047776 Itopt_. 2H6 - process Description AROC10R SKCT] ONJin. rnocKSS in pktah. D. B1-KN1): NQj FI1,THAT] ON AND STORAGE (Cont' d.) The filter press 1b cleaned after about 5-7 batches or as needed. During the filtration, 2-l6 oz. samples are taken to the laboratory for control analyses. If the control analyses pass specifIcatlons, the batch Is transferred from the product tank to a storage tank. After several batches have accumulated In the storage tank, the con tents of the tank are mixed, and composite samples are taken for lot analyses. Three underground (15,000 gallon) tanks and five above-surface (each 20,000 gallons) are available for storage of the finished products. The blend tanks, finished product tanks, and Aroclor 12*12 and 1 storage tankB are blanketed with nitrogen. The pressure of the nitrogen gas Is 10 pslg. Nitrogen blanketing maintains the electrical properties of the Aroclors. The Aroclors from the storage tanks are drummed, pumped to tank cars, pumped to tank trucks, or transferred to Department A-246 or H-2*l6 mixing tanks for the production of Pyranols, Inerteeris, or pydraul A-200. Hatches of Aroclor 125*l-mix arc mixed In the //I blend tank. This operation consists of a mix of 10# xylene and 90# Aroclor 125*1. Xylene is received In 55 gallon drums. The flash point of xylene is 85F. Mixing, sampling and drumming of 125*)-mix 1b accomplished directly from the blend tankB. After the blending operation, the blend tank must be cleaned. The bottom outlet of the tank is opened and the tank is cleaned out with live steam and then blown with air. F HY-PRODUCT HYDROGEN CHIPRIDE The by-product hydrogen chloride from the chlorirmbors is collected in a common pipeline header and flows to the centra] HC1 absorption unit to manufacture Muriatic Acid in Department F-218. If Department F-218 is unable to handle the off-gaB, it may be sewered at Depart ment 2*iG by passing through a Haveg S-K drowning Jet. The removal of HC1 from the off-gas concentrates the original quantity of hydrogen and air to a point well within the explosive limit. Therefore, It Is essential to either dilute this gas going up the vent stack or increase its velocity past the flame propogatlon rate (15 ft/sec). Thib is accomplished by introducing a sufficient quantity of Btcam into the vent stack. To remove vaporized and entrained impurities in the HC1 from the chlorinators, the gas passes through a condenser and mist eliminator. The entrained liquid, which 1b primarily biphenyl, is sewered. MONS 047777 9. Dept. 22)6 - Process Description AHOCJOi SECTIONJV COMMENTS ON PROCESS CHI ORINAT]ON STEP A . RAW MATERIAL Y] K] .T)S Biphenyl and chlorine are reacted to form a chlorinated biphenyl called Aroclor. The yields on biphenyl and chlorine vary with the type of Aroclors produced. Each particular type of Aroclor has Its own standard yield factors. Yields are not reported for the Indivi dual type on Aroclor each month. An average yield Is reported monthly and compared with standard and theoretical yields which are calculated according to the quantities of the various Aroclors produced during the month. Standard and theoretical conversion factors used in computing chlorine and biphenyl yields are listed below. STANDARD CONVERSION FACTORS AROCIOR ___ __ 1?A2 1248 129l| 1260 1262 123? 1P9H Xylene CHIORINE jl/11 Product .9032 1.0323 1.6130 1.2903 ].^3^ 0.680? 1.0l)5? BIPHENYL /// Product 0.6l80 0.5380 0.21978 0.1)368 0.1)163 0.7216 0.4480 THEORETICAL CONVERSION FACTORS AROCIOK CHIORINE H/jj Product 1332-1P32 1 ]h?-1?A2 ]]2)8-lPl)8 HJll-lPJl) 1160-1260 116?-1262 121)2)-10 Xylene 0.61)00 0.82) 00 0.9600 1.0800 1.2000 1.2A00 0.9720 DIPHENYL Product 0.6891 0.6919 0.9367 0.l)79Jl 0.1)11)7 0.3976 0.1)279 HONS 047778 Dept. Ph6 - Process Description JO. AKOCIOR SECTION IV COMMENTS ON PROCESS CliJ OK] NAT] ON STOP B. CAPACITY The monthly production capacity of Department 2H6 la P,^00,000 pounds of Aroclors on a 7 day per week basis. The capacity of the chlorinators is a function of the following variables. 1. Hatch Cooling Rate - Chlorination of biphenyl is an exothermic ?caction"wH3ch produces 510 BTU's per pound of chlorine gas undergoing a reaction with biphenyl. Biphenyl can be chlorinated as fast as the exothermic heat can be removed from the batch and maintain a batch temperature of 150C. ?. Chlorine Plow Rate - The rcaotion time decreases as the chlorine Tlow raTe" Increases. The chlorine flow rate is approximately 1000 pounds per hour per chlorlnator. A maximum chlorine flow I rate of 1500 pounds per hour per chlorlnator can be attained if desired. The concentration of chlorine in the "Bnift" gas is another factor controlling the rate of chlorination. 3. Catalyst - The chlorination rate increases when ferric chloride catalyst is added to the charge. The best results are obtained when the biphenyl charge contains .05# ferric chloride catalyst. C. y.AI'LT/ Some of the factors which affect Aroclor quality are as follows: 1. Temperature - According to research experimental results, the cHiorlnatSr temperature must be greater than ]?0C at the beginning of the chlorination reaction to produce stable Aroclors. ?. Catalyst - Good contact is necessary to produce stable Aroclors. Tt~ls 'suspected that agitation and circulation of the reactants improve the effectiveness of the catalyst. The catalyst is also responsible for the chlorine positioning on the biphenyl molecule Pcrric chloride catalyst may be responsible for producing the desired end product. Results of research work concerning catalyst and isomeric distribution are given in Appendix N. < MONS 047779 Dept. P*l6 - Process Dcscriptlon n. AKOCipK (. SECTI ON IV COMMENTS ON PROCESS CHI OR] NAT] ON_Si;KP C. QUALITY (Coni' d.) 3. Raw Materia] Purity - The purity of raw materials can affect the quality of Aroclors both directly and Indirectly. In a direct manner, impurities which are ionic lessen the resistivity of AroclorB. Distillation of crude Aroclor separates most of the ionic impurities; however, minute impurities can be carried over to the receiver tanks. Attapulgus earth can remove the remain ing impurities in moBt instances. If any ionic impurities remain after the earth treatment, the resistivity of the AroclorB will be low because such impurities will conduct electricity even in minute concentrations. In an indirect sense, impurities such as sulfates in the chlorine gas, will poison the ferric chloride catalyst and thus unstable Aroclors will be produced. The chemistry and mechanism of the catalyst poisoning are not known for certain. i|. Catalyst Basket - During the latter part of I9C9, the catalyst ( fSaslc&t was removed from one of the five chlorinators. The material produced in the chlorinator without the catalyst bas ket analysed as normal material. This material was used by a customer wi th satisfactory results. The catalyst baskets may be removed from the other four chlorinators as they fail. The only restriction on materia] made without the catalyst basket is that it will not be sold to General Electric, or Westinghouse. AERATION AND DISTILLATION MUNS 04778G Steam is not applied to the coils of the blow tanks when aerating Aroclors 1 ill2 and 11*18. This prevents the loss of Aroclor vapors. Eighty psig steam may be applied to the coils when aerating other Aroclors. High moisture may be removed effectively by blowing the crude Aroclor with dry air. Vacuum trouble on the stills Is usually caused by flashing of product, air leaks, plugged vacuum lincB, or Improper functioning of the vacuum Jets. Plashing can usually be stopped by operating the still at a slower rate or increasing the flow of cooling water to the vapor condenser. . Vacuum trouble can be traced systematically from the jets and usually ' isolated. High color and entrainment will result from overheating (around ?^C above normal distillation temperature) Aroclor, faulty operation of the distillation step, or boiling down thestill too far. (Tars will carry over). The "tail-end still fraction (tars) is a AROCLOR SECTION IV COMMENTS ON PROCESS BIENDING AND FI I.THAT] ON Attapulgus Earth la added in the blend tanks to reduce moisture and inorganic chlorides as well as improve electrical properties. If batches do not meet specification (See Appendix B), redlstillatlon may be necessary. The Attapulgus Earth is roasted for *1 hours at 250C before addition to the blend tanks when earth treating Aroclor 12^2. MQNS 0477S1 Dept._ ?46 - Process Description AROCIDR All 'KNI)]_X_A_ EQUIPMENT 1,1 ST This section contains an equipment list with each piece of equip ment listed by Item numbers In a consecutive numerical sequence. Miscellaneous items of Dept. 246 such as Instruments have not been assigned Item numbers. Equipment without Item numbers is not included in this equipment list. All equipment of Dept. 246 will have Item numbers assigned sometime in the future. This equipment list should be expanded as additional Item numbers are assigned. Item Equipment No. Name Equipment Number Description 101. Hi phenyl Transfer 19-0582 Taber vertical submerged cent, Pump 66-3930 pump, size C-3, 2?" inlet, 2" outlet. Connection bronze except shaft which is monel. Motor is 3 HP, 1800 RPM. 10? Diphenyl Storage Tank 21-2210 Tank purchased from Rogers and Wrigler. Capacity is 25,000 gallons. 10' 6" Dia. x '10'6" long. 3/8" plate shell. Design pressure is 50 psi . 103 Diphenyl Head Tank 21-0767 16-7225 Tank made by Graver. Dwg. C-799. Steel tank 4'6" ID x 5'6" Btr. side, dished heads, shell 3/8", top head 3/8". and bottom head 3/4" with 1/2" Jacket over it and ending 9" up on tank side. Welded throughout. Test of tank is 60// and Jacket is 105// hydro, pressure. Mixer is Mixco Model N33075, gear driven propeller. Motor is 440/3/60 TKKC, 1725 RPM. lO'l Biphenyl Peed 66-7224 Durco Horiz. Cent. pump. 2" inlet, 2" outlet. Cap. 100 CPM Motor is 7i HP, 1760 RPM 105 Chloririator 7/1 21-3261 Tank made by Nootcr. Dwg. K-800. 3' ID x 16' long with pig. head. Shell 3/8" and head 7/16" thick, 3/16" Jacket over lower half of tank. 106 Chlorlnator #2 21-3245 Same as Item No. 105. RUNS 047782 Dept. P46 - Process Dcscript]on AR0C1.0R APPENDIX A EQU1 PMKNT IJST (Cont'd.) Item Equipment No. Name___ Equipment Number Deseriptlon 107 Chlorlnator #3 21-3251 Tank made by Leader Iron Works. Otherwise, same as Item No. 105. 108 Chlorinator #4 21-1283 Same as Item No. 107. 109 Chlorlnator #5 21-1432 Same as Item No. 107 110 //] Mi Bt Eliminator 15-0581 Tank made of carbon steel. Element made of carbon steel. Design pressure is 50 psig. and design temperature is 300E. 111 //2 Mist Eliminator 15-0582 Same as Item No. 110. 11? H3 Mist Eliminator 15-0583 Same as Item No. 110. 113 flh Mist Eliminator 15-0584 Same as Item No. 110. 114 //5 Mist Eliminator 15-0586 Same as Item No. 110. 115 Chlorine Mist Ellm. 21-4042 Tank made by Alpha. Carbon steel construction. Coded tank. Element 316 stainless steel. 15" dla., glass fiber inverted type. Design pressure is 50 psig and design temperature is 300P. ]]6 Chlorine vaporizer 38-51187 Chlorine vapor!zer made by Armstrong Company. 8-5/8" OD x 11' long. Carbon Btecl construction. Chlorine side steel designed for 250 psig. at 400E. Steam side designed for IOC psig at 4oOE. 120 1?1 Knockou t Chlorlnator //] Pump 19-4305 66-8109 Steel vertical 60 gal. tank. Durco Mark II horiz. cent. pump. Inlet is 3" and outlet 1b 2", ductile, iron, with Duramctallic seal and Marizel lubricator. Rate is POO Ql'M at 25' static head Sp. Gr. of 1.5. Motor is 10 HP, 1800 RPM. MONS 047783 Dept. ?1|6_- PrOC_eBB_ Description 15. AKOCLOK APPEND] X A EQU1 PMKNT LIST (Cont'd.) 3 tem No._ Kqulpmcnt _ Namc_ Equipment Number Dcecrl ptl on 3?? Chlorinator H2 Pump 19-)I306 66-8110 Same as Item No. 121 1?3 Chlorinator #3 Pump 12t| Chlorinator #)| Pump 1?5 Chlorinator #5 Pump IPG Plow Tank //? 19-^307 66-8111 19-'I308 66-8112 69-3892 66-6509 21-2086 Same as Item No. 121 Same as Item No. 121 Same as Item No. 3.21. Tank made by Graver. Iwg. K-863. 7' x 7' str. sides, dished heads 1/?', shell 3/8", 5 turn coil of 2" pipe supported on brackets welded. 1P7 Wow Tank #2 Pump 66-2956 69-0577 Taber horl 7.. cent. pump. Type 1.-2. 2\ " x 2". Semi-steel with monel shaft and water jacketed stuffing box. At 20' Btatic head, rate is 80 GPM, 1.5 Sp. Or. at 500F. Motor is 3 HP, 1800 RPM. 1?8 l Air Dr^er lJj-010l) 1 Anders Iykens Corp. Air dehydrator. Two code welded tankB filled with 55 lbs. activated alumina. I>wg. #6)156. l?9 ' '.^oV/ Tank f/i Pump 19-0629 66-9080 Same as 1tem No. 127. 13 ' , still Hi 20-001)3 Vacuum Btlll purchased from Graver. Dwg. C-809. Size 6' Dia. x 5'6" Ig. on str. side, shell, dished head 5/8". 60# hydro. pressure test. 131;, Kurnaoe //I 13? Still //3 Pump ( 27-001)5 19-059)) Steel heater furnace. Steel shell 3/16" x 3'9" dia. x 1)' 10j" Ig. lined with insulating fire brick. One col 3 2" xHy pipe, 3? turns formed Into a ?' dia. coi3 with spare blocks and legs. Dwg. E-806. Taber vert, sub, cent. pump, type J.-2. CaBlng, yoke, and Impeller made of steel. 2" Inlet and 2U outlet. Length 7 '9". Capacity is 76 GPM, static head 15', Sp. Gr. 1.8 at 700E. Motor is 5 HP, 1750 RPM MQNS 0*7784 Dept. ?kbProcess Description 1 6. AKOCIOU APPKND1X A BftUlPMKNT LTST (Cont'd.) 3 tcm No EquJ pmcnt __ Name Equipment Number Dcscript!on 333 sun 7/2 20-0062 Vacuum Bill] purchased from Nooter. IWg. 69,l`l. 61 11) x n'lO" sir. shell Internal, pipes, standard dished heads. Glass wool Insulation 3" with l/2" finished coat. 13'l Furnace //2 20-0066 Same as Item No. 133. 135 SU11 //2 Pump 66-1759 69-1277 Taber vertical sub. cent. pump. Type Cl.--1|, x 2", else 38JI. Pump Is dynamo steel. Capacity Is 75 GPM at 25' static head, Sp. Gr. 1.8, Motor Is 7i HP, 1750 RPM. 136 Condenser |/1 38-0770 Heat exchanger made by Nooter. Dwg, B-651. 12" dla. 5' long having nineteen 2" 01) 11 ga. monel tubes, monel tube sheets, monel reducer, and carbon steel Jacket and back up rings on flanges. 137 Condenser #2 38-1370 Same as Item No. 136. 130 Recei ver Tank //I 21-0771 Vacuum receiver tank made by Nooter. Dwg. C-795. SI ze Is 5'6" dla. x 5'6" str. side, 3/8" shell, 1/2" bottom and removable head. 2" IP, size xHy monel coll with 2" Inlet and 1" outlet. 3 turns, 5' dla. along side and 3 turns spiral on bottom. 60// hydro, pressure test on tank and 300// on coll. 139 Receiver Tank //2 21-1377 Tank made by Nooter. ix#p, C-Y9 Same as 3 tern No. 338. , 1^0 Receiver Pump 3 66-9067 Rlackmer pump, lypc PA-501,, bronze 69-0565 rotary pump, monel shaft, C.l. base. Capacity 1 s 50 GPM, 1.65 Sp. Gr., 350 to 500F. Motor Is 2 HP, 1750 RPM. i'll Receiver lump #2 66-5670 Same as Item No. ]<10. 69-1258 MllNS 047785 ltej.it. 2D 6 - Process Description 37. AKOCLOH AP1'KN1>3X A EQUIPMENT LIST (Cont'd.) J tom Np_j_ KquJ Client __ Name EquJ pment Number Description ].J|2 Hlend Tank #1 21-0779 Tank made by Graver. Dwg. K-86?. Welded steel tank, 7' dla. x 7' high dished heads l", shell 3/8"- All surfaces Bpraycd with .005)" zinc then .003" tin. 2" xlly pipe col 1 and supports. Case bronze stirrer and bronze shaft. Test of tank is 60# and coll Is 300# hydro, pressure. ]l)3 Hlend Tank #2 mu Hlend Tank lamp 21-1399 66-0217 19-1757 66-3718 Same as Item Ho. Ill2. Taber Horlz. Centrifugal pump. 30l| s.s. 2" x l|" capacity 6o GPM, 100' head. Motor Is 10.0 lip, 1800 RPM. 3113 36" Sparkler Fi 1 ter 15-0238 Filter made by Sparkler Mlg. Co., 33-P-12 horizontal plate filter. Typo 30;l s.s. Jacket tested for pressure of 30 psi . I'l6 Finished 21-0780 Filtrate receiver tank. Dwg. K-862. Product Tank #1 Same as Item No. ill2. 1/I7 Finished Product 21-111 00 Tank made by Nooter. Otherwise, Tank #2 same as Item No. Ill2. 3H8 Storage Tank #3 21-0768 Tank made by Graver. Dwg. C-609. Horizontal steel, 10' dla. x 26' long on str. Bide, dished heads, shell 4", head I/16". Test of tank is 60# and coil is 300// hydro, pressure. All coils, supports, inside surfare sprayed with .003" zinc and .053" tin. lll9 Storage Transfer 19-0585 Taber Vert. Sub. Pump. IVig. A-387. lamp #3 66-0853 Type C-3, 2" x 2", C.l . body, length 1.1'6". Cap. 30 GPM, 60' static head, Sp. Gr. 1.18 at 370&F. Motor is 3 HP, 1800 RPM. fi150 Storaf Tank #<l 21-0769 Same as Item No. 3l|8 Tank { fi133 Storaf Transfer 19-05814 Taber Vert. Sub. Pump Type 1.-2. lamp t 66-1501 2g " x 2". length 11'6". Cap 30 GPM at i)01 static head. Motor is 3 HP, 1800 RPM. MUMS 047786 Dept. 246 - Process Description 38. AKOCIOR API'KNJ>] X_A WJ2?1iiNT U ST (Cont1 d . ) 2 icm No. Equipment Name Equipment Number Descrl ptl on 15? Storage Tank //5 21-1310 Tank made by leader Iron Works. C-609. 10'Oft x ?6' long on sir. shell. Same as Item No. 148 for other characteristics. 153 Storage Transfer 19-0929 Same as Item Ho. 151, except ltunp Tib 66-085O length is 4 '7". Vjk Storage Tank i/8 21-3526 Slpha tank 1P'6" dla. x 2?' high. 20,000 glllon storage capacity. Aluminum constructed Dwg. TS-D-30]]. 155 Storage Transfer 19-3172 Durco pump, model WH2 A13oy constr. Pump 7/8 66-2631 2" x l|", 8" impeller. Cap. 160 GPM at 55' head. Motor is 7i HP, 3740 RPM. Vj6 Storage Tank in 21-21)04 Alpha tank. 13' OD x 20' high. Vertical tank, constructed of 3/8" mild steel. Capacity is 20,000 gals. 157 Storage Transfer 19-2077 Pump made by Blaokrner. Monel shaft, Pump 7n 66-1691 2-J" x Pi". Cap. 90 GPM. Vj1 head. Motor is 3 HP, 1750 RPM. 158 Scales 167 Wow Tank #1 24-0246 2/1 -0187 21-0750 Made by Toledo Scale Co. 800// capacity, dial type scale. Tank made by Graver. Dwg. K-863. 7' dla. x 7' str. side, dished heads shell 3/8". 5 turn coll of ?" xHy pipe. ]69 Surge Tank 22-0751 Cyclone collector made by Graver. Dwg. B-695. 48" dla. x 2y" on str. side, 3' 6" long and tangential inlet near top of side. 3/16" steel throughout of welded construction. 170 Cl ty Water Pump H1 69-1083 69-3365 Taber Horiz. pump. Model CH5, 3" x Pi" 9" impeller. Cap. 180 GPM, 50' head. Motor is 7i HP, 1800 RPM. 171 Cl ty Water Pump i/P 17? Off-Gas Mist Eliminator 69-2078 66-1796 21-5150 Same as Item No. 170 30"0D x 13'-3" straight side, steel construction, vertical for Brink Filter Element //15-0630(//?496 carbon 173 Off-Gas Heat 38-5588 8'long x 16" 01), 2 pass on tube Exchanger Bide, Z> bafflco, cteel construction. MQNS 047787 Dept. 246 - Process Description ( AKOCIOH APPENDIX A EQUIPMENT LIST (Cont'd. 19- 3 torn No Kqui pincnt Name EquJ pment Number Description 100 Exhaust Blower 11-0265 Made by American Blower Co. ,ypc 450E. Capacity Is 6408 SCPM at 1310 RPM. Dwg. K-10699. Motor js 19 IIP. 189 Coke Scrubber #1 21-0756 Scrubber liquor tank made by Graver. Dwg. C-800. 4'6" Dla. x 5'6" on Str. Side. Coll 3 turns of 1-?" x Hy pipe. 186 Coke Scrubber 7/2 21-1396 Same bb Item No. 185. 200 Cyclone Separator 21-1413 Separator made by Helntz Stec. 3' ID x o' high tangential separator with Integral vapor pipe complete. 203 Air-cooled Heat 38-5328 Air cooled heat exchanger made by Exchanger //5 Dialer. Cooling capacity is 1,200,000 BTU/hr. Steel construction except for aluminum fins, van motor is 2 IIP, 1150 RPM. 203 Steam Vacuum Jet #1 35-3523 #2 { Worthington 3-stage vacuum Jet. 204 Steam Eacuum Jet =H2 35-1686 Same as Item No. 203. 205 Steam Vacuum Jet #3 35-3533 3-Btaee porcelain Kubatl vacuum ejector with 10" 11) porcelain conden ser. Jet haB a capacity of 10///hr. air at standard conditions. Jet designed for ISO// steam and 2 mm Hg absolute. 206 Off-gas Drowning Jet 35-47! Made by Schuttc-Kocrtig. 8" Haveg fume scrubber. Complete with stand ard nozzle. 207 Drying Oven 14-0138 Grieve Hendry drying oven, 440 V., 3 phase, 60 cycle, manual reset temp, controller range 0-400C. 210 Air-cooled Heat 38-5564 Same as 1tem No. 201. Exchanger //I 66-8113 213 ( 212 Air-cooled heat Exchanger //2 Air-cooled Heat Exchanger //3 38-5565 66-8114 38-5566 66-8115 Same as Item No. 201. Same as Item No. 201. 213 Air-cooled Heat 38-5567 Same as Item No. 201. MONS 047788 Exchanger //4 66-8116 20. Itopt. 246 - Process Description AKOCnOK APPKND3X A EgUlPMKNT LIST (Cont'd.) ] tem No._ Equipment Name Equipment Number Dcscrlptlon 214 Air Dryer 14-0138 215 City Water 69-4363 Worthington 3CNFK84 with 8" impeller Circulating Pump 66-8179 and Monsanto standard base. ?]C TollBh Filter //9 Storage 15-0633 Alsop filter model No. PAK 125-4, 316 s.s, 6,000 in.^ filtration area, 840 in.3 volume. 237 Polish Filter #10 Storage. 15-0634 Same as Item No. 2l6. 218 Polish Filter flll Storage 15-0635 Same as Item No. 216. None Chlorine Pressure 29-1547 Recorder Made by Taylor Instrument Co. Pressure Recorder with 2 pens. Range 0-100. None Chlorlnator Flow Recorder 29-2019 Made by Taylor Instrument Co. Flow Recorder - Controller Cat. No. 137RF135. 12" chart, 0-10 Sq. root chart. None Water Meter 29-2486 Made by Worthington Corporation. 3" model JH turbine type water meter. None #] Still Tempera 29-3885 ture Reoorder Made by Leeds & Northrup Co. Temperature Recorder. Range 0-^l00C. None fil Still Absolute 29-1170 Pressure Controller Made by Taylor Instrument Co. Absolute pressure Recorder - Controller. None None 200// Steam Flow Reoorder 29-0835 fi2 Still Absolute 29-3353 Pressure Controller Made by Bailey Meter Company Flow Recorder. Made by Taylor Instrument Company. Absolute pressure Recorder Controller. None //2 Still Tempera 29-0844 ture Recorder Made by Leeds 8c Northrup Co. 6 point Temperature Recorder. None #2 Still level Controller 29-1463 .Made by Taylor Instrument Co. Liquid level Recorder - Controller. MOMS 047789 y Dept.. SM6 - Process Description 2] AUOCIOK APPEND!X_A EQUIPMENT LIST (Cont'd.) ] tern No. Equl pment Name____ Equl praent Number Desert ptlon None Chlorlnator 29-0280 Temperature Hecorder Made by Leeds & Northrup Co. 12 point Temperature Recorder. None #1 Blow Tank 29-2916 Temperature Recorder None 80# Steam Plow Recorder 29-5^52 Made by Taylor Instrument Co. Temperature Recorder Controller Adjusts 200# steam to #1 Blow Tank Cat. #86 RM43186-12. Made by Poxboro Company. Type T37, recording flow meter with Integrator and Indicator. Meter body 316 s.s. Integrator for 80#, 1\00F. Bteam. None 200# Steam 'y Plow Recorder 29-5^53 Made by Poxboro Company. Type T37 Reoordlng Flow meter with Integrator and Indicator. Meter body 316 e.s. Integrator for 200#, 510P. steam. y MONS 047790 Dept. ?56 - Process Description 22. AHOCIOH APPEND] X_H SPEC]F] CAT]ONS The following Is a list of the raw materials used for the manufacture of Aroclors. Specification sheets are Included where they exist. Material Code Raw Material 8?601 HI phenyl 33500 Ferric Chloride 38800 1.1 me 19509 81059 Attapulgus Earth Chlorine 53099 65005 N1trogen Xylene The following Is a list of the finished products manufactured In department 256, Specification sheets are Included where they exist. Product Code 811.12---------------- 821.15 8ll0l(Elect & Non-Elect) 81102 (Elect 8e Non-Eleot) 8ll03(Elect 4: Non-Elect) 81105(Elect 8c Non-Elect) 81107 8)101-81102 (Mix) 82868 Product enc Aroclor 1252 Aroclor 1258 Aroclor 1255 Aroclor 1260 Aroclor 126? 1252 - 1258 Mix Montars 1, 2, 3 and 5 MOWS 047791 MONSANTO CHEMICAL COMPANY OMOAMC CMIMIC4LI DIVISION v-amwmwm SPECIFICATION MATERIAL DIPHENYL (BIPHENYL) CHCMICAL FORMULA MtTIKMl COOK 82601 UIINO DIPT!. 246 ANNISTON PLANT MOLT. 15*1 -20 ^U^fN|JIDEB BPBCB 0^0 AMPLE POP ANALVBIB 2 x 16 oz. w.M.Bottles UNRESTRICTED INFORMATION Routine Tests Appearance and Color Crystallizing Point OENERAL INFORMATION Distillation Range: First Drop to Dry Point Specification Light Yellow cryst. Solid 68.7*C, min. 2.5*C, max. Must lnolude 255*C within Range Issued^; R m in Method Number 10,252 10,298 10,299 This specification Is the property of Monsanto Chemical Company and la for Internal use only. pH IN M INC Vo U/M> MONS 041792 Monsanto enoANie chcmIcal* eiviaiOM W, G. Krummrich Plant RAW MATERIAL SPECIFICATION PRODUCTION T. W. Dalton C . A . Pratte mol wl. 162,21 MATIRUk 33500 P1. ANT Ferric Chloride Anhydride UttMO DOT*. WGK 233 "jAirTraK upplicr McKesson St Robbins --------- 1--------- --------------------- APPROVALS M. A. Terpstra QUALITY CONTROL (CMt Chmi*t) W. J, Gresham CHCMICAL FORMULA Fe Cl, ACTKRIBTIC UNRESTRICTED INFORMATION Appearance Assay Sulfates Ferrous Salt* Solubility: 10:10 of Water 10:10 pf Formula 30 Alcohol Black powder or Granules 97.0%, min. 0.05%, max. Trace, max. Complete to slightly turbid, max. Complete to slightly turbid, max. J.F.Q, 16-A 22-570 120-570 S-570-1 112-B W Kutln Antlylf, Alt Artmly* MfiMil Milf< MQNS 047793 Monsanto I.ANIC C HA MIC A l_ tllVIK ( RAW MATERIAL. SPECIFICATION PRODUCTION P. E. Heislei* C. A. Pratte MATKAiAL CAM 38800 WGK DAT, CFFKCTIVC 7/21/66 APPROVALS Lime, Hydrated UAINA DKPTI. 222, 246 UPPLItft . Mississippi Lime Co, M. E. Gibbs OUALIT V CONTROL (Chimt Ctfmtti) W. J. Gresham Ca (OH)2 6/20/63 C NAPACT eristic AMPLC POP ANALTIII 1 x 16 oa. W.M. Bottle Appearance Fine white or slightly gray powder, free from lumps or gritty material Assay (CafOHh) 92.00%, min. ( Carbonates as (CaCOj) 3,00%, max, Magnesium 0.50%, max. Sulfates (as $0*) 0.30%, max. 10, 188 10,191 10,193 10,192 10,189 Supplier's certificate of analysis to be sent on day of shipment to: Chief Chemist, Monsanto Co., Monsanto, 111, ( (10 HtlEAi, Antfyslt, 4ff ffAif, 4ml,nd A, Mfy. MONS 0A7794 Monsanto MATCAIAL COOK 19409 Atlapulgus Earth 200/UP PLANT UIINI DCPT1. W. C. Krummrich Plant WGK 246 ( RAW MATERIAL SPECIFICATION 1-21-66 UPPLIKA Mineral fc Chemical Phillips Corp. PRODUCTION P. E. Heialer APPROVALS W. D, Robinson C. A. Pratte . 9UALITV CONTROL (CM*I CAMt0 W. J, Gresham CHEMICAL FORMULA Clay 11/15/62 CHARACTERISTIC 2 x 16 02. W.M. Bo tile a LIMIT* UNR ESTRICT^D INFORMATION ;rj Volatile Matter (at 950*C.) |R) Meah Teat: Through USS 325 6 - 6% 90%, min. J. P. Prader MKT MOD This material ia not accepted without the supplier's analysis of the above properties. ( (IV AmJfaJa, 4ff ilMri If nkmiI Mlf. HONS 047795 Monsanto MATCHIAL COD* 43099 PLANT Nitrogen Gas U*IN DIPY*. . RAW MATERIAL ( SPECIFICATION WOK DAT! KPPCCTIV* FEB 1 8 1965 See Below Air Reduction Sales r.n . APPROVAL! PRODUCTION J.M.C.. P.E.^.. W.B.P.. C.H.S. PtaCAPCH uFS R.W.B.. H.W.K.. M.A.T . W.D.R. . J.A.s! QUALITY CONTROL (Chill CheatIII) C.H.C, W.J.G. C.H.R. J S.M. >1 PKCWIPTION CHIMIOI rgWMVLA Grade - 0. P. Special Nitrogen Yy ____ cmaract*qi*tic AMPLK POP ANALVtl* ----- LIMIT* IMUIOIV D- 0**1* UITM Assay (1) Oxygen Hydrogen DewPoint Nitrogen Argon Oxygen Carbon Dioxide Acetylene 99.9%, min. 0.1*, max. 0% . -76F Typical Analysis 99.78% 0.12* 0.1* <.00005* <.00005* (l) Nltrogeh plus inert rare gases (?) Any analyses to be obtained from supplier on request. (5) B-215, C-216, 244, 246, 247, B-254, A-255, 256, 267, 270. ( ': : - (10 RmMm AnafyaU. All tlAsti Analyse* *y repeal mmly. MONS 047796 Monsanto OR4ANIC CMIMICAL* DIVISION MATCMIAL CODS 64005 PLANT MATCMIAL UAINS 0PT. 5* Xylene WGK ( RAW MATERIAL DATS CFPCCTIVC A-255 SPECIFICATION 6/21/66 Chem Tech PRODUCTION J . E. Smith P ROC UltMlNT A. H. Smith APPROVALS C. Eaker (Nitro) DUALITY CONTROL /CM*/ Ch*n/*f> W. J. Gresham POCMIPTION CMIMICAL FORMULA C6H(CH,), mol, wt. 106.1$ 7/12/63 AMPLC POM ANALYSIS 1 x 16 ot. C HAM AC T KAlt TIC UNRESTRICTED INFORMATION J. P. Prader (R) Appearance Clear Colorless liquid (R) Sp. Gr. @15.5/15.5 *C, 0.860 - 0.870 T-2516 (R) ( Distillation Range 1st Drop Dry Point 137*C., min. 143*C., max. T-2516 100% over in 5*C., max. Acidity Sulfur compounds No free acid Free of H2S and SOz Supplier's certificate of analysis to be sent on day of shipment to: Chief Chemist, Monsanto, Company, Monsanto, 111. (. (A) Analfl$, Alt (Mm Antlya4 by w|m*I wily. Mows 097797 Monsanto FINISHED PRODUCT SPECIFICATION PRODUCTION T. W. Dalton W. E. Ault UPRODUCT | CHLORINE Liquid tOCPT. | 232 Pl'AnI D WGK PRODUCT COOK 81059 " u " Sales and Internal ALII CODI j JUN 2 9 1%6 3060-000-06-03 RCfCiACM N. F. Mueller Duality control fCMr camioO W. J. Gresham CHCMIC 4k 0MUL* 70.914 6/24/63 AMRlS POA ANALVIIP 1 x 40 ml. Beaker 3/4 full CMAAACTCAIITte UNRESTRICTED INFORMATION (R) Appearance Clear heavy liquid (R) Color (R) Moisture Amber to greenish yellow .015%, max. (R) NVM . 01%, max. J. P. Prader MTNN 10, 748 10,748 12,793 12,793 Iron as: Fe. FeClj, 6H*0 Report % Report % 10,bSS When ufted in manufacture of AC1 product, the specification on Iron as Fe is 20 ppm max. (H.V.Moss) For use in Depts. 264, 256, 236, 243, 244 and 251. ( MONS 047798 4mrtlvifcv rtauett Only MONSANTO CHEMICAL COMPANY ORSANIC CHIM)CAL| DIVISION PRODUCT COOS 81115 W. Q. Krummrlch PlanLf Internal FINISHED PRODUCT ACM COOK" SPECIFICATION IOKPT. OR JO* ___ _246__ J.F.Q.. ~PnOOUCT fTVrf Num) TTP* . Aroclor 12?2_____________________ (MCS - 'product (OhMilMlffOT*) ' TVPI 5236 Chlorinated Biphenyl C HIMICAt FORMULA 236) Issued APR 7' W. CL. Kc New ItAMPLt FOR ANALVm _____________ 2 x 16 oz. w. M. Bottles Routine Tests Appearance Sp. Or. (825/15.5'C Acid Number Color, APHA H20 General Tests Chlorine Specification Clear Liquid 1.266 - 1.276 0.014 mg. KOH/grm. max. 100, max. 55 ppm., max. 51.5 - 52.5* Method No. 10,114 10,087 10,084 10,620 This specification is for Internal use only. MONS 047799 MONSANTO CHEMICAL COMPANY OftQAHIC CHCMCAtt OIVUION Krummrlch and Anniston FINISHED PRODUCT ' SPECIFICATION AoouCT'irT>4 __ Aroclor 1242 ____________ VrODUCT Mmf) RROOUCT COOK lOKRT. OR JOB 81101-82612 IW0K-g46-Ann.27 Sales INLU COOK 1040-240-04/ll/l6-03/09 Issued W. 0. Xrummrich Whnfc By. ,>v, -6 ih CNRMCAL FORMULA 5-4-61 Mixture KAMRLK ROM ANALVMt -___ 3 X 16 OZ. V. M. BQttlMM___ UNRESTRICTED INFORMATION Routine Tests Condition Color, APHA Sp. Or. (25/15.5*0) Acidity (mg, KOH/g.) Moisture (H*0) (ppm.) General Tests Distillation Range (ASTO D-20 Corrected) 10)6 Distilled by wt. 90)6 " " " Viscosity 8100'P (SUS) FlaBh Point (*F) Fire Point Specification Clear 100 max. 1.381 - 1.392 0.010, max. 50, max. 325*C, min. 360*C, max. 82-92 338 - 392 None WOK Anniston Metnod no. 10084 0-1 10084 046 10114 052 10087 050 10620 047 10117 14-31-54 10086 10123 10123 049 14-28-54 14-28-54 HONS 047800 MONSANTO CHEMICAL. COMPANY ftftftAMC CNIMCAkf MVIMM W.O.K. and Anhlaton FINISHED MtQDUCT mioovcT cods 81102 UM Sales IALU COM |<mre46i90K | 27 Ann. SPECIFICATION 1040-260-04/11/16-03/09 ftftOOUCT (W9* TVftB Aroolor 1248 Electrical Grade (pyranol 1498) fftOPWCT fOft199l ftlSj TTftft Issued 1/10/64 Corrected 2-16-64 Mixture MOL *T. MPiniMI IPICI Of 2-12-60 lAMPLft fOft AMALT9W 3 x 5 Pt. Amber Bottles UNRESTRICTED INFORMATION Routine Tests Color, APHA Condition Sp. Or. 965/15-5" C , Aoidlty (mg. KOH/gra.) Moisture Refractive Index 925*C Inorganics (Free) Chlorides Pour Point Dielectric constant (1000 cycles 9100*0) Resistivity (500 VDC 910p*C 0.1" QAP) as OHM-CM x 309 Hydrolysis Stability Test (as Chlorides) Monsanto Stability Test (as Chlorides) Distillation Rqnge (ASTM D-20, Corrected) 10f Distilled by Wt. 90% Distilled by Wt. Specification 50, max. Clear 1.405 - 1.415 0.010, max. 35 PPm., max. 1.6285 - 1.6305 0.05 ppm., max. 0*C, max. 4.5 - 4.7 500, min. 1.0 ppm., max. 0.5 ppm., max. 5*I5*C, min. 385*C, max, Method No's. WOK Annlstor 10,084 14-44-54 10,084 0-1 10,114 14-49-54 10,087 14-42-54 10,620 14-53-54 10,125 14-34-54 T-2092 014 10,115 14-27-54 11,608 14-36-54 11,607 14-35-57 Tl2087 010 11,503 14-61-57 , 10,117 14-31-54 general Tests (made only on request) Sulfates Dleleotrlo Strength 925*C Fire Point Viscosity 954.4*0 (SUS) Corrosion Test (6 hrs. 9210*C with bright aluminum foil) Change In wt. of A1 (%) None 35 KV, min. None to boiling point 73 - 80 0.0 12,169 - - 11,605 043 10,123 14-28-54 10,086 14 -A -52 10,126 14-55-57 (over) MONS 047001 A. C. Color, APHA A. C. Condition A. C. Acidity (mg. KOH/g.) A. C. Inorganic {Tree) Chlorides 60, max. Clear 0.010, max. 0.05 ppm., max. OENERAL INFORMATION Specific Heat Fixed Chlorine 0.27 <17.5 - "8.5* 10,08" l"-""-5" 10,08" 0-1 10,087 1"-"2-514 10,118 010 MONS 047802 MONSANTO CHEMICAL COMPANY OAOANIC CHEMICAL* DIVISION Krumnrleh and Anniston FINISHED PRODUCT SPECIFICATION ~PRODUCT (TYarie J Aroolor 1254 'PRODUCT flam*) PRODUCT CODE 1 DIPT* OR JDD 81103 - 82613 1WGK-246-Ann.27 Issued 7/15/64 USE w. o. Krummr'lcn riant Sales SALESCODS By /YU H 1040-280-04/11/16-05/09 . TYPE Non-Electrical Grade TYPE MOL *T. 5-4-61 Mixture ' -` SAMPLE POM ANALYSIS - 5 x 16 .pz, W. M. Bottles________________________________ UNRESTRICTED INFORMATION Routine Tests Color, APHA Sp. Or. 065/15.5*0 Acidity (mg. KOH/g.) Moisture (Ht0) (ppm.) Oeneral Tests - Flash Point Vlsooslty S210*F (SUS) Specification 100, max. ; 1.495 - 1.505 0.010, max. 50, max. None 44-48 WQK Annlstor Method no. 10084 10114 10087 10620 046 052 050 047 10125 . 10086 14-28-54 049 MGNS 047003 Monsanto ANNISTON AND KRUMMR1CH Rinishid product SP1CIP1CATION Hwluifttw 1 P. E. Htlilti Ui.ll 1 W. . Ault HMWIT Pt*"fAroclor 1260 Electrical Grad* Anniaton 'wmvnn. Krummrich B110S WGK___ Ann. t WC,K - ? Salww 5/25/66 1040-290-04/11/16-03-09 IMIIMIU---------------------------------------------- ---------- W . D. Robtnaon w*6iTv *TN*b rciuwcfMMiM/ O. E. Dolin W. J. Greaham (MlMt *6 PMWW* WT. 2/7/62 BNBkrDi 3 x 5 pt. Amber Bottle a 6HTt UNRESTRICTED INFORMATION (R) Color (APHA) 150, max. (R) Condition Clear <R> Specific Gravity 90. IS. 5*C. 1.555-1.566 (R) Acidity (mg KOH/g,) 0.014, max, (R) Moiature (HjO) (ppm) 35, max. (R) Viacoatty 0 210T. (SUS) 72 - 7$ (R) Refractive Index 0 25 *C. 1.6455 - 1.6470 (R) Inorganic (Free) Chloride# <R> Pou^r Point (*C) (R) Diatillation Range 0.05 ppm, max. 25 - 34 (AS'fM D-20, Corrected) 10% Diatilled by wt, 385 - 396'C. 50% Diatilled by wt. 390 404 *C. 90% Diatilled by wt. 400 - 420*C. (R) Corfoaion Teat (6 hr a. 0 210*C, with bright aluminum foil) (R) Change in weight of Al (0) (R) A C. Color (APHA) (R) A.C, Condition (R) A.C, Acidity (mg. KOH/g.) (R) A.C(. Inorganic (Free) 0.0 150, max. Clear 0. 014, max. Chlpridea ' 0, 05 ppm, max. (Over) J. P. Prader 1 MM 100S4 10084 10114 10001 10620 10006 10125 10118 10115 10117 14-44-54 14-49-54 14-42-54 14-53-54 14- 4-52 14-34-54 14-48-57 14-47-54 14-31-54 10126 10004 10004 10007 10118 14-55-57 14-44-54 14-42-54 14-48-57 HONS 047806 Xemttnt AH |l/o AnmlyitA & raot Oalv ONRESTRICTED INFORMATION (Cont'd.) Charactcri.tic Limit a_________________________ Method Fla eh Point Fire Point - Fixpd Chlorine (%) (R) Dielectric Strength 0 50*C. (R) Reactivity (500 VDC 100*C. .1M gap aa ohm-cm x I0y) .(R) Dielectric Constant 1000 cyclee, 100*C. None None 59.5 - 60.5 30 K.V,, min. 500, min. 3.6 - 3.0 WGK 10123 10123 10068 11605 11607 11607 Annitton 14-20-54 14-20-54 14-13-54 14-35-57 14-36-4* RESTRICTED INFORMATION (R) Monaanto Stability Teat (Aa Chloridee in ppm.) GENERAL INFORMATION (R) f' (R) Evaporation Loaa after 6 bra. O 100'C. (%) Stability teat after 10 daye at 100*C. in glaee reeled in air. 0. T, max. 11503 0.2, max. 10116 No liberation of chlorine or chloridee 14-61-57 12-32-54 MOWS 047805 Monsanto ANNISTON And KRUMMRICH FINISHED PRODUCT SPECIFICATION AROCLOR DISTILLED 1262 use ANN. b WCK 81107 -WCK_____ ("T,Ann-2 1 WGK-241 Sales MAR 02 1966 APPAOVAlt 1040-300-04/11/16-03-09 P. E. Heiler {ill* ' W. E. Ault ieiAiTOM W. D, Robinson .U.L,', W. J. Gresham ci D j. Dolm 1/24/62 PDA AnALTIII pMuioTv 2 x 16 o*. W.M. Bottles J. P. Prader UNRESTRICTED INFORMATION (R) Appearance <R) Color (R) Specific Gravity @ 90/15.5 *C. (R) Acid No. (mg. KOH/g.) (R) Viscosity @ 210'F. GENERAL INFORMATION Pour Point (ASTM) Distilling Range Total Chlorine Specific Gravity Temperature Coefficient (85 - 130*C,) Viscous liquid APHA 150, max. 1.572 - 1.583 0. 014, max. 86 - 100 SUS 35 - 38*C. 390 - 425'C. 61.5 - 62.5% 0.001/*C. 10084 10084 10114 10087 10086 MUNS 047806 (R) Routine Analysis, Alt others Analysed by request Only MONSANTO CHEMICAL COMPANY Krummrlch and Anniston , FINISHED PRODUCT V SPECIFICATION "VVotiVcT (Ttmi* --) PROOUCT COOK 82868 UM IALU COOS lOIPT. OR JOt IWOK 246 Ann. 2' Sales Issued nil 15 19S4 w. Q v^Kruir^Ich^piant- By See Below TtPt Montars 1 and 2 "PRODUCT TYPO Polychlorinated Polyphenyla Mixture MOL *T. wniimi inn or 6-15-61 IAMPI-1 Fe ANALYIU g x 16 oz. W. M. Bottles UNRESTRICTED INFORMATION Routine Tests Specification Anniston WOK Method No. Appearanoe Black Solid 14-17-52 11321 General Information physical Properties (Typical Values) Nontar X Montar 2 Softening Point (ASTM E-28-51T) Acidity 54-l6o*C Slightly Basic 70-170`C Slightly Basl Chlorine content 56-42)6 44 - 4856 CaO Pe Benzene Insoluble Flash Point 5-1536 O.5-I.O56 --------- ---500-620'F 5-1556 0.5-1.OJ6 12.5)6 ... - RESTRICTED INFORMATION Montsrs 1 and 2 sre the still residues from distillation of Aroclors 1042 and 1248 respectively. Composition of these Montars Is not controlled, being entirely dependent on conditions required to make acceptable dlBtllled product. Sales Code Nos. Montar 1 6405 - 001 - 04 - 03/09 Montar 2 6405 - 002 - 04 - 03/09 M0NS 047807 MONSANTO CHEMICAL COMPANY OROAMC CHEMICAL! DIVISION Krummrloh and Anpiaton FINISHED PRODUCT PROOUCT COOK 82868 I DEPT* OR JOR Iwgk 2^6 Ann.27 USE Sales ALE! CODE SPECIFICATION PRODUCT (TreMa *See Below TYPE Montars 5 and 4 PRODUCT (CMaslMf Wan) . TYPE polychlorinated polyphenyla issued JUL151964 W. 0. Krummrich P.iant By ~Yfi DT)),.L 1 mol rr. 6-15-61 Mixture 1AMPLE FOR ANALTMI 2 x 16 oz. V. M. Bottles UNRESTRICTED INFORMATION Routine Testa Specification Anniston WOP Method No. Appearance Black Solid 14-17-52 115; Oeneral Information Physical Properties (Typical Values) Montar 5 Montar 4 3oftenlng Point [Method A STM E28-51T) se-ies^c 92-206`C Acidity Slightly Basic Slightly Basl Chlorine Content CaO 50-52* 5-10* 54-5656 5-1056 ' Pe 0.5-0.6* O.5-I.O56 RESTRICTED INFORMATION Montars 5 and 4 are the still residues from distillation of Aroclors 1254 and 1260 respectively. Composition of these MontarB Is not controlled, being entirely dependent on conditions required to make acceptable dis tilled product. *Sales Code Nos. Montar 5 6405 - 005 - 04 - 05/09 Montar 4 6405 - 004 - 04 - 65/09 <r HONS 047808 23. Dept. 246 - Process Description AROCLOR APPENDIX C PHYSICAL AND CHEMICAL DATA Physical Constant Data sheets which are available are listed following this page. HONS 047809 PHYSICAL CONSTANTS DATA niUTHIHT-- 1 ' ! i i i i-- "IitmucturaI formula ' R2601 DIPHENYL TMnuo n,p, Metzner 2/12/43 'Ha'v.l *' 6/22/43. 1Zll/44. Rev. A.M. Ellenbung 6/26/57 FwiwH IblacylM WtM tettUBBL. Blllin Paid 4 760 -- eUta nlllm Paht 4 -- Wllnt Prill 4___B_ CiwUlllIlM Pdi4 IMIlf PalM CgHs UfiHiT 265 C -iia 69, Q^C 69ur oo Bellateln V - 576 iouiiei PATK cn*m.HUB66r him&mr~n-1641-42 Inl rrll Tahlra 1028 fSwann file 1137 1935 Swann Curve* 1934 Inl Trlt T.hl.. 1028 I^elllg ttinritv a___ 77/4..C Swillt&ijjltf.f Pwadt m 68.a comidtm < Ewwiiwi MuctKwWBt t i Rid SwcUw ftotmct) Ullta Villa Stadrua flliww) Ylmtllr more mhsul. 70 129^2 C hlitlllty 9 W8a whip urn* Senxenc.jB 21 lathanol lr 0.8896 1 041 a 23 lha par gal. D = 1.68822 Swann glia 4137* lain Int Crll Tahl.a 1028 29. 8 Say, Bee. 31.2 . 5 dyne/cm Insoluble________________ 8..8go8-tg.a/nll nPPi ag. oauoilvYetmnt., C. K571 ga.. //110n0n ga.. aanaUlv.eawntl 1317 gf..//mlOOugg. aaoliventi 25.1 8. /100 g. advent Swann glia 1127 A 1020 Int. CHI Dow Seidell Tahl.a 1928 1943 _1941_ 15*1 1941 1941 nl> PM*F fin Hanot CaAmlgi Ha l FaaMlon dsirn r.up). nil (15) sgaF - closed 'eup --apen eup---270 pan gm mnl a 1804 4 ma.~a Bng. -owm.--mo -MrM8 Swann.Flla 1137 A (1943) Inl, Crll. TahUm 1928 UMtHUJlJf.____, fl-255-CCrtimi 136.5 BTU/lh^ 43 BTU/lb 528aC- . 41 4 Aim ahanlnla Swann Flla 4137 A (1928) RfcE CB 884 <1856) Rev.-Scl. Inal rnmenl 1,363 -flMO 28 8 gm.ral par gm Lange Handbook 1831- ( 53.1 BTU/lhh MUNS 047810 NOTE:-Fllea of W-P-Metanar. St. Loula Twldly KMMlma. Klathl__m_ _nJ)l 1ItDk- I Pnkr>. WMeatL.e.ai ler Annlalnn Plant Report cnpv In Synthetic Ufugi" fi'--' :SD liSi CD* PHYSICAL CONSTANTS DATA ( 2) rSKRIC CHLO^Da, ANHYDROUS rA'w Pc'-r.-S*!t Chcro.- Co. towtoit Pena-jSkit ChtmTCb.' 6-57 Found tolcculif Wclht NAME , ! Boilins Point 1 7E0 tins ... FeCL. 166.22 , SOURCE 4 DATE Ttf 1 Ref-1- Boilini Point H _m Mdf. uilllilm Point Solution Poinl Soecitie Giovilv Specific Gravity Pounds per Gel. t PC Coefficient ol Emotion Rclnclivt Index# nt Infra Rod Sooetrum Ult Violet Swctni (Rtftrtnct) yi entity _________ ,_________________ ViKOSitV # Sublime a MiQlllly In wan Sol utility in Soliftlllty In ..____________ V. Sol. Ihont rinel_______ R.f.l. Flh Point 9F fUahodJ Fin Point C Ufilit of Combustion , . He ol femillen Therail Sialllly Icil.Al/'inilO_________________ HLent Heat of Fusion ' Latenl Heel of Vio. ' Sotclllc Hell , Cillltol Tnotfitin V" *1 ' "*,*"R<ftye..ic4 *. LC>i o jrenn-djui v nem. co. Tecn. Data Shea .It Spec*. ToxititV fdvt Rtkrtnet) moms 047811 'yC'T-C-.-T^rMr^fttn^hvnlH-nfu^t Yrlmttd BMitrfr f Manimttf Chtmltal Ou idditienat aktHt if ntttuvy. . CD*** *i* 38800 PHYSICAL CONSTANTS DATA HYDRATED LIME (Cslclum Hydroxlfc) A *** 1-25-57 FonmU Moleculu WlIlM mAmc BaIIIm Pair! (KOh Mltatfemt bi Bel IIm Point M m CivsiiIIIzIm Point m tokleillJoHnt PotiH Giovihr # . 20^C toiiclllc GisvUff Pm) p Gil. * 50 *C CnHidint * Ekmwm ftitiKtln Mu : Mil Rtd Swell* IHttfmn) Utlll Vtold SNdlMI tKHtrma) Vlauiltv * Vlccetltv Sri Sil lAIIRv In VMa \ Seldtllttv tn Mitllllv In OOUWCK 0 PATO____________ Ce(QH).____________________ Ref. 1______________________ 74. ID *____________________ ___ Ref. 1______________________ Whits pnuirlsp Ref 2 DrnmpojiAA 2.2 4 D 1.574. Ed 1.545 Ref. 1 Ref. 1____________________ _ ___ Ref. 2_____________________ _ ___ Rei--1______________________ .185%ftOC. .077*8 11 DC Ref. 1 ' Soluble In eclds end WH4 :i Ref. 1 _ Flash PiW P /m*m\ Fin wm K Uti Dl CiriMiittan Hll1 si FsmttaL ______________________ Tlumil StollltY (eS-Au/iln.) Lint HiM sl FalM , Lrtml HiM iIVmi.___!______________________ SmcKIc HlS Critlcil Tsmntm CrHIcil Pratnot _. Bitigrl^lm flee* References; 2. JnfoPrpotlon bv Vendor 1 i U i o . 1B5R ToslcHv ta<* n,i'r,wi _ HONS 047812 tr ... PHYSICAL CONSTANTS DATA CHLORINE ' T OUPILIBIV 9*j4 W. H. Demeree WAMI Ftiwrtl Wrote Wrtt______ ___________________ 7-29-54 ~70IJ tQUBCt 4 OAT________________ ADUttttfll______________ ______________ _____ fillliMfelftlMM . tlllNfeM *100U ' ... .. t 34.05 -71. Ji _AP1___________________ ___ Ref. 1 -100.04 Ref. 1 -rxrM------------------------------ Ref. 1 imlilUilM Nft H ||i/iiIm hin , iXS,. O'CHM ss; m --------------------- Funds p*m.# ] c -100.44 1715 1.404 Ref. 2 Ref. 2 Lenee CrtlHctel d EnmlM r ffiettaMat 0*Cj *i (1 11M toictnrt 2rtMI Ultfi VMft IdnImi/K^vmmJ ICAlltV , . 1.47 Ref. 2 VI cull** la * tirilttr It fi & tftlifrJd Solicitor fc----S&ec.lflc erayltv a J0*0 1.377 Flirt Pote F llutti}: s tPiw'c ; 111 Hi III u ert Hut tf Fialtt | LM MtttaMafVu. Sdelite Hut j CdUtil Taturtn j Ctl Iril Pimm* ! cu imMIm fiaMlal | * KeF. 1 - Calc. from det. date 1 us 1 o ' cHy I'CfW Ktfrrtbi) 144*C 76.1 ttmAfl. Ref. 2 . Rftf. 1 HONS 047813 PHYSICAL CONSTANTS DATA TcMflwer--' AROCi-OR TDMFTETD1V---------- A. M. Ei.fr bora _____ NAMNEAM^ f oiimili itoliculu Weijht ____ __________ Awuuitu______________________ Boilini Point M 780 m Rnte Belli Ejuj j( 3 m " Baling fan* 8 _n ----------- --- Bsiiu* foil ,.j*i _________ !ystilliijjV PoM..... ......................... IfcJljj* Ptuol _________ __________ SsUudPtinl Sjwtilit ChhIy ^$7 25 C.___ ScKilii CwilK 25/15.5-C, Poundl ptlTlI. 25 % CoiWiciMt ol Emumon 25-65 'C. Rilntiivo iiidiii2VC. o l Mil Rd Swcliw iR'iw**l Ullil Violat Spedfun (Htfmtnctj Yiiwltof ...'ilSi'U jVjlikcvoMntuv J- i*0r0" . ...-------- --....... SuUfiMilBi Dyff/cm 6 ZO'C. SoliiiltHY In WUr kllOllltyJn. 3A~Aitc-.ol @29C. ScliRiltlv in Pyr dir.f __ @ 10C. i'oaTV ` 1.. CelPiitat-Mol: 325 - 160 C. No" c rviialliairg _L._38Q_ 1. 381 - 1. >92 11.50 1.62-15 - 1.6265 J4rJ5_SilS_ 45.1 . Ir tr: .bIt 23. 3 g./IOQ cc 1 32 5 8./IHQ cc_ ,---------------- u, ------- lauaiijLBAii. . iLmoi. Bui!. UP 3 935; 2Ui:= 55_____ M. B. OP-1.5 Sprtf fit'll- _2. J 4.56 M. B. QP-iiS ____ u _ _ _____ .U -CiU. Sci.. lfi-. J 952 M. B. OP-l '6 flirt Point HfikUioH E.o.c, Fin FoM^C c o.c, Hilt ol Contiatlon HW oi fWWUrt IMM ssilffir Icnym-'nli'.) Utnl H*8 of FjbIm ______ LnamtRny*,.ci>1/pro,_ Smith HU gc,____ Clllicrt Tww&fMtffC CmicH Pttmie Pr>,,r pr;r e rm* Conductivity, cal/ _____ __________ cm/ C/oec. D e ec* r;c Gorta- jOO 60 cy. 180 C. Ncnr 61____ 0.29? 0- >*0 1 4 1 C . c.r lonn 24,0 e 2* C. 4.3 -4.9 L CAjcuIiltd____________ M B. QP. 16________ I-L'Jie p..ii. jj OP~i~A~iL~ Tonicity (Civ* Htftrrntt) _ Con'aci Medea Dpi/ HONS 047814 Q.-2J_S.____ t I3> PHYSICAL CONSTANTS DATA TflTTcTuR AL^ORMUL A ( ceumiBiY A. M. Ellenburg FoomHi Mo tttllftt WoltM naMi BoIIIm Poll* S 7(0 aa Bo fto Bs lint Point a mn s itaiiiino Point Ik So itlon Point Ranee n a d NlA s *NA a iss 1a Sooclllc Ginllv 65/15.5VC. round* por Gal. * 25 C Corilicionl o1 Ewauion !R-6R0r Rotisctin Mu* !S"r" i Ini i Rod Soectfua IRifmoci) Oilto Violet Spodnoi (Htftmni Vlncoolb# lpOF. YncodtY* su SolItillltv In WSa Solilillitv in 3A Alcohol 6 25UC. Sol utility In Fyrld(n* 0 29UC. bill 4-2f 57 C12 HR Cla 292 (Ave.) Y#11nw Tlnt^ri Mnh Oil 345-385C. 185-2IODr ci. ______ tOUaCC PATE Monsanto Bull. OP-115(1 !' St It Non-crvstalllzlnff II 1.445 1.405-1.415 12.04 0.00070 cc/cc/uC. 1.6285-1.8305 IS SDec Ifteat Ions 9/9/54 M.B. OP- 115 SDeclfleatlon 9/9/54 73-80 BUS 44.2 Insoluble 15 g. /100 ce 111.4e./100 cc M.B. OP-115 J. CoU. Scl. 7.166.(1952 M.B. OP-115" SI Fiiah Point PK/UuMJ c.o. c. Fir#P*WC HUit at ConfaiutlM c. o. c. Hsi of Fotadlon , IISimp Stkllity tcoi.Ai/aln.) LMent Haat ol Fiaion LMffilHiMot V. cal/gm.___________ SokHIc Han A 25UC. Cilllcil Taaottohn . Cillical Pianino_____ Oilnoelitlon Comtirt _______________ Sr eelfie Heat 0 &00UC. 196r.' None 54 0.277 0.358 Pour Point 0C. or lower > Thermal Conductivity, cal/ r cm/vC/sec. 23.6 S 28V im Dielectric Constant. 100"C.. u ta cy. ______ 4.5-4.7 Ii o M " Calculated M R. OP-11S n-------- ---------------------------------------- IS To be Dubllahed M.B. OP-115 TOXiefiV (Civ* Rtftrtnct) Contact Medical Dept, --M.B. OP-115 PHYSICAL CONSTANTS DATA luimut* 1 1,1 rTT 1 " ... ITRUCTUMAL OohMuTa ABOCL.OR I?54_________________________________ (SHFIIID IT A.M.EUerbjr* na|mc Famuli MdIkuIm ieiilK Aa fia liM Pair! M160 ML DotllaiPiilid M 3 h Rarge " W lino Point M qrtAlliino Paint Ik SolMen Point teaclfic Gravity Specific firovllye Ml oat Ml saa 25>/2SwC. 65/15.5C. Ak CotlficloM<D Emersion 25-65"C. HofioctlwMu* , >r*i Mia Rad Seadnen tmitmal Dili* Viold Saactiwa iMtmai Vlautilv 210"F Vluaiitv # mo TsmIm Dvnes/cm tel JH'Ittv ia M* ._ telifcihtvin 3A Alcohol 627WC WiWWyIb Pvrldlne A 31C. DAT! _ 4 25 4T Cl? HaClt, ______________ 326 'Art.)__________________ Pal* Yellow ls-D-a oil 365-40iC iao.??nr touweg a PATt Monsar, o Ral' OP-llHl95f M Non - c r v sI.bIaIz In a II 1-536________________________ 1.495-1.505 12.82 ,,__________ 0 00068 cclcc/~C. 1.6370-1.6390 Rpr lf r*Hr>r x 2/\4/SV MU QP.1 ' Snrntf(ration 7/14/56 44-48 SUS MB OP- 115 50.3a2bC. 42.0fll00u *a Insoluble 10 g./lOO ec______________ 114 e. /100 cc ll It M II flash Point*/Started/ C. 0. c. flra Point C c. o. c. Ikl Hf at FanaMon intrail Sltellltvfcal./iu/'Bift.) LAMl Hula/Fmi* ' 1,6 ontHodotVai. Settitle Had rl/grn 6 2iT'c. CtH leal Taneefitiin Critical Pratura None Jimt_________________________ II 50 0.261 Calculated MB OP-115 t relflfc Hr.tt- B 300 C.____________ 0.336________________________ Ppur Point . m Vm TVermdl Conducttvtt. Cal/ cfn/6ClSec. g 9Rr r II | To be Dublished i Dielectric CoMi'an!. 100C. 0 6 b cv. 1 o 4.15-4.35 MR - OP -1 lf> HONS 047816 TexlcHv Afepnc; Contact Medical Dept. M B - OP-115 PHYSICAL CONSTANTS DATA PHYSICAL CONSTANTS DATA `lURVIuift 1 1 .. 1 STRUCTURAL FORMULA A ROC LOR 1262 (Ki ' TBMP1UB ______ A. M. Elltnburg7/3/57 DAT! ci7 Formula Molttula MW* NAME BoIIIm Polfl 4 760 M lira Poll! a <-i7h3ci7________________________ IQUACg 0 DATt Llyht veil, ntteky Rnntn 390-425C Monnnntp Bulletin OP-1J5 " (1956 fin BoiliM Palm 8 *4 cmwililv Point ______________________ Ifal Solillon Point Sooclllc Giovltv 80/15, S"C Sncitic Gravity 25/25C Pound* pa Gal. * ax C Cooltldont d twanlon 25-rso RofiictlvtMai jS5r i Mi Rat Saactnan rituinM/ Ultii Violat Sooctna nktfrmcii VlKOllly 0 21 QF____________ Yilentity {ii fel Ulllty in Ha felliMIltv In So) Alltty ll 1.577-1.567 1.64$ 13-72______________ ,,_____________ 0.00064 cc/cc/l'C 1.646-1.650___________________ SDecs. 4/11/55 MR n^.nx______________________ Afi.tfin SITS Specs. 4/11/55________________ Flnlt Paint F mrnhpil FlraPointC tlH tl emanation . Hti ot Bunion__ TtwiMi ability(MLAi/alflJ____________________ LImt Hta ol Ptalon limlHaMof Vid. ' SHtitle Hut cm IcnlTanonrAn cm ten Pittuit , Dllrelation CooMat ptur Point Nona None 25-38C MB OP-115__________________ (1 < M I u MONS 047818 i Toilcttv fGivt Rafaranta) Contact Med. Dept. MB OP-115 NOTE: Then fata ikoaU w( * rataat ad muM* CIU(tal Company. Ut additional (/mhk^. 2b. Dept. 246 - PyocesB Description AROCLOR APPENDIX D UTILITIES The utility calculations are based on design calculations for a 28.8 million pounds per year production rate. The breakdown of utility usage by Individual equipment Is only on estimate. The estimates of utility usage are average values In most Instances as It Is difficult to measure the operating time and load for a particular piece of equipment with great accuracy. The total usage of each utility was taken from the cost sheets. Estimates of Individual operating time and percentage of the total load were made to calculate the distribution of utilities as given In the following pages of this section. ( HONS I Dept, 246 - Process Description AROCLOR APPENDIX D UTILITIES (Cont'd.) 25. 1. Power Consumption A. Electricity - 440 V., 3 phase, 60 cycle Item Equipment No, Motor Motor HP Peak Load KW 101 Biphenyl transfer pump 103 Biphenyl head tank pump 104 Biphenyl feed pump 3.00 .75 7.50 2.6 0.7 6.6 Monthly Usage KWH 80 240 1980 121 122 123 124 125 127 129 132 135 140 141 144 149 151 153 155 157 170 174 180 #5 Chlorlnator pump #4 Chlorlnator pump #3 Chlorlnator pump #2 Chlorlnator pump #1 Chlorlnator pump #2 Blow tank pump #1 Blow tank pump #1 still pump #2 still pump #1 Receiver pump 2 Receiver pump Blend tank pump #3 Storage transfer pump #4 storage transfer pump #5 storage transfer pump #8 storage transfer pump #7 storage transfer pump #1 city water pump #2 city water pump Exhaust blower Miscellaneous Totals 10.00 8.8 10.00 10.00 8.8 8.8 10.00 8.8 10.00 8.8 5 .00 5.00 5.00 7.50 4.4 4.4 4.4 6.6 2.00 1.7 2.00 3.00 1.7 2.6 3.00 2.6 3.00 2.6 3.00 2.6 3.00 3.00 2.6 2.6 7.50 6.6 7-50 6.6 15.00 13.0 135.75 119.8 3040 3040 304 0 3040 3040 200 1580 1580 2340 20 20 200 160 240 200 80 80 2340 0 0 26,860 HUNS 04V 82Q Dept. 246 - Process Description AROCLOR APPENDIX D UTILITIES (Cont'd.) 1, Power Consumption (Cont'd.) B. Electricity - 110 V., nne phase, 6o cycle Peak Load Equipment KW Lighting 15 Instrumentation 2 Miscellaneous .2 Natural Oas Totals 20 Item No. Using Equipment Normal Use SCFH Peak Use SCFH 131 #1 Furnace 1200 132 #2 Furnace 1200 Totals 2400 2400 2400 4bo6 3. Compressed (plant) Air Item No, Using Normal Use SCFM Peak Use SCFM 127 148 #2 Blow Tank #3 Storage Tank 60 60 200 200 150 #4 Storage Tank 60 200 152 154 #5 Storage Tank #8 Storage Tank 60 60 200 200 156 #7 Storage Tank 60 200 Miscellaneous Totals 10 370" 200 ITOT 26. Monthly Usage KWH_________ 3600 1440 2150 7190 Monthly Usage MSCF 430 430 boO Monthly Usage MSCF 2590 90 90 90 90 90 MONS OA7821 Dept. 246 - Process Description 27. AROCLOR APPENDIX D UTILITIES (Cont'd.) 4. Nitrogen Item No. Using Equipment Normal Use SCFH Peak Use SCFH Monthly Usage SCP 142 143 146 147 148 150 152 #1 Blend Tank #2 Blend Tank #1 Product Tank #2 Product Tank #3 Storage Tank #4 Storage Tank #5 Storage Tank Totals 3 3 3 3 3 3 & 4 4 4 4 4 4 4 23" 2140 2140 2140 2140 2140 2140 2140 14.980 Purchased Water Item No. Using Eauloment 130 131 203 204 205 206 #1 Still #2 Still #1 Vacuum Jet #2 Vacuum Jet #3 Vacuum Jet S-K Drowning Jet Miscellaneous Totals Normal Use 0PM 3 3 20 18 15 25 2 "BE" Peak Use QPM 5 5 20 20 20 30 10 TOT Monthly Usage M. Oal. 150 150 870 770 650 120 100 2810 High Pressure Steam 200 TSlfl at' 3B8F Item No. Using Equipment 167 203 204 205 #1 Blow* Tank #1 Vacuum Jet #2 Vacuum Jet #3 Vacuum Jet TotalB Normal Use Lb.Ar. 210 450 400 325 1385^ Peak Use Lb .Air. 310 670 615 500 2095" Monthly Usage M. lb. 150 320 290 240 100O 7. Low^Pres sure^S team Item No. 102 138 139 142 143 146 Using Eaulment Biphenyl Storage Tank #1 Receiver Tank #2 Receiver Tank #1 Blend Tank #2 Blend Tank #1 Finished Prodi Tank Trf.n 1 a Normal Use Lb./hr. 700 700 700 200 200 200 2700 Peak Use Lb ./hr. 900 ' 900 900 300 300 300 3800 Monthly Usage M. Lb. 500 500 500 150 150 150 T9S0~ MONS 047B22 28. Dopt, 246 - Process Description AROCLOR APPENDIX D UTILITIES (Cont'd.) 7. Low Pressure Steam (Cont'd.) Item No. Using Equipment Normal Use Lb ./hr. Peak Use Lb./ir. Monthly Usage M. lbs. 1*17 #2 Finished Product Tank 200 148 #3 Storage Tank 700 150 #4 Storage Tank 700 152 #5 Storage Tank 700 154 #8 Storage Tank 700 156 #7 Storage Tank 700 Miscellaneous 1400 300 900 900 900 900 900 2800 150 500 500 500 500 500 1000 Totals 7800 10,500 5600 MONS 047823 Dept. 246 - Process Description 29. AROCLOR APPENDIX E PERSONNEL Departments 246, A-246, B-246 and C-246 are closely related. Operating personnel may work In all of the departments In a given day. For this reason, the description of operating classifications and assignments for departments 246, A-246, B-246 and C-246 Is given as though all four of the departments are Just one department. Operating Classifications Job Premium Operator Second Operator Repairman Standard Operator Porter Swingman Number of Men 7 day/week Schedule 10 & 4 Schedule 43 43 i1 22 ii 10 TOTAL 12J 9i The swingman works two shifts per week (Saturday and Sunday) as a relief foreman, two shifts as a repairman, and one shift operating the premium Job. There 1b an open shift on the second operator Job that Is covered by overtime. The premium operator and second operator cover three shifts each (Jay. The repairman works the day shift, and with the Bwlngman, there Is 7 days per week repairman coverage. Standard operators work the day and middle shift 5 days per week. The porter works half time In department 246 and half time In department 243. The premium operator has lead responsibility for his shift. The work force works all three departments Aroclor, Pyranol and Pydraul as one coordinated operation. The assignment of time Is 70# to Aroclors, 15# to Pyranol and 15# to Pydraul. Operating Assignments: MUNS 047824 Premium Operator: Has overall responsibility and operates 5 chlorlnators 2 stills and covers the necessary absences of the standard operator. Second Operator: Operates 2 blend tanks filter, 2 finished product tanks, storage tanks, makes Pyranol and Pydraul mixes, loads trailer, and tank oars, charges chlorlnators and transfers receivers and also belongs to the Fire Brigade. Repairman: Unloads cars and trailers of Biphenyl, Trichlorobenzene and Tetra-Trichlorobenzene and finished product, makes weekly safety lnspectlot 30. Dept. Sk6 - Process Description AROCLOR APPENDIX E PERSONNEL (Cont'd) Standard Operator: Fills, stencils and labels 5 gallon, 30 and 55 gallon drums and clean-up asslgnmenta when not drumming. The Standard Operator loads cars and trailers as does the second operator. Porters Cleans office, control room, repair room, wash room and smoking shelter. Swlngman: Works one day per week as premium operator, two dayB as repair man and two days as relief foreman. As relief foreman takes overall supervision on day shift on weekends including arranging for maintenance, night sheets and line-up of work. < ( MOWS 047825 Dept. 246 - proceBa Description 31. AHOCLOR APPENDIX F PACKAOINQ & SHIPPINO Aroclor, Pyranol le Pydraul and filled about half in drums and half in tank care or tank trucks. A substantial amount (about 40) of Aroclor is used to make Pyranol and Pydraul. Sales are largely directly to the customer. The remainder is in bulk shipments to the J. F. ftueeny Plant. All electrical grade tank truck shipments are made in the customers trucks whloh are stainless steel. Non-electrical Aroclors are shipped in leased trucks and may be iron although other materials of construction are suitable. Pydraul is shipped in steel tank trucks. Electrical grade Aroclor and Pyranols are shipped in solid aluminum lined tank cars or in lined tank oars either 4,000 or 8,000 gallons in capacity. The lining is either tin, zinc or aluminum spray because iron and iron oxide contamination is detrimental to the electrical properties. Electrical grade cars are either owned by Monsanto or on a long term lease. Non-electrical grade Aroclor is shipped in Bteel cars. All electrical grade lots and bulk shipments of non-electrical material are sampled from the final container. That is all tank cars and tank trucks are sampled and analyzed after loading. All electrical grade drums are sampled from one of the drums. Tank cars and tank trucks are inspected to be sure they are free or dirt and water or other foreign material before loading. HeelB are drained before loading some materials. Car washing when necessary is done by the repair track. Tank cars are sealed with a numbered aluminum seal. MOMS 0 4 7 B * 6 Lacquer lined drums are used for Aroclor and Pyranol and plain steel drums are used for Pydrauls. A summary of products, weights and containers current use is as follows: Weights and Containers Product 5 Qal. ICTfaT-------~5TTJar------ TT TC 1232 1242 1248 1254 1254 Xylene 1260 1262 .. 55 . 60 _ 60 - -- 60 _ 60 _ 600# 600# 600# 600# 600#' 600# 600# Yes Yes Yes - Yes - _ Yes Yes Yes - YeB - MCS295 - - 645# -- Pyranol i486 - - 675# -- Pyranol l48l - - 675# - Det_1_2f|6_=_Jroce8B_De8orlj2tln AROCLOR APPENDIX P PACKAOINO & SHIPPINO (Cont'd.) Product Pyranol A-13B3B Inerteen PPO Pydraul A-200 Pydraul 280 WeiKhtB and Containers 5 OalT------ 30 OaT.------- 55 Oal. |5 36# IW, 6o 360# 59 6o " 645# 625# TT - - YeB - TC 4000 Oal. 4000 Gal. 8000 Oal. HONS 047827 Dept. 5*16 - Process Description AROCLOR APPENDIX 0 MATERIAL BALANCE 33. The material balance on Dept. 246 was made with a minimum of field measurements. Most of the estimates on the following page check fairly close with actual raw material usages that can be readily measured. The exact composition of some of the Inter mediate process Btreams Is uncertain. ( MOMS 047828 Dept. 246 - Process Description AROCLOR Appendix q SUMMARY OF MATERIAL BALANCE RESULTS AROCLOR 1242 Raw Material & Cost ($/lb.) Usages - Lbs/100 lbs product Material Balance Theory Material Balance Usages lbs/100 lbs Biphenyl (.0662) 58 63 58 Finished Prod. 1 Filter Cake 3.5 Still Bottoms 5 Off-Oas HC1 63.O Chlorine (.0217) 84 91.8 42 Finished Prod. 1.5 Filter Cake .05 Vacuum Jet 2.8 Still Bottoms .95 Alr-HCl Mix ture 44.50 Off-Oas HC1 91.80 Ferric Chloride ( .129) 0.03 Attapulgus Earth (.0302) 15 Air (.00055) 3 Lime (.0100) 0.5 03 .15 3 0.5 .03 .15 3.0 0.5 AROCLOR 1248 Biphenyl (.0662) 52 56.5 52 Finish Product 1 Filter Cake 3 Still Bottoms .5 Off-Oas HC1 56.5 Chlorine (.0217) 96 103.2 48 Finished Prod. 1.5 Filter Cake .05 Vacuum Jet 2.55 Still Bottom: .95 Alr-HCl Mix ture 50.15 Off-Oas HC1 103.20 HONS 047829 These raw materials are the same for production of all Aroclors 1. Dept. 246 - process Description 35. AROCLOR APPENDIX Q Raw Material & Coat (i/lb.) Biphenyl (.0662) SUMMARY OP MATERIAL BALANCE RESULTS (Cont'd.) AROCLOR 1254 Usages - Lbs/100 lbs product Material Balance Theory Material Balance Usages Lbs/100 Lbs 46 49.8 46 Finished Produc 0.5 Filter Cake 2.8 Still Bottoms 0.5 Off-Oas HC1 49^8 Chlorine (.0217) ( Biphenyl (.0662) Chlorine (.0217) 108 117.5 AROCLOR 1260 40 43.4 120 128.8 54 Finished Produc 1 Filter Cake 0.05 Vacuum Jet 6.8 Still Bottoms 0.95 Alr-HCl Mix ture 54.7 Off-Oas HC1 117.50 4o Finished Produc 0.9 Filter Cake 2.0 Still Bottoms 0.5 Off-Gas IIC1 43.4 60 Finished Produc' 0.5 Filter Cake 0.05 Vacuum Jet 4.8 Still Bottoms 0.95Air-HCl Mix ture 62.50 Off-Gas HC1 128.60 ( HONS 047830 36. Dept, 246 - Process Description AROCLOR APPENDIX H ATMOSPHERIC DISCHARGE - WASTE DISPOSAL Lbs. per C lbe. Total LbsAr based on of Aroclor Produced 1. HC1 Fumes from blow tanks 0.01 2,000 2. HC1 fumes from other tanks vented to atmosphere 3. Chlorine gas from chlorlnator vented to blow tank 0.01 UNKNOWN 2,000 UNKNOWN 4. Aroclor & Biphenyl vapors of tanks vented to atmosphere UNKNOWN UNKNOWN DlBOharge to Sewers 1. HC1 from chlorlnators 2. CI2 from chlorlnators 2.5* 2.0* 500,000* 30,000* 3. Condensibles In chlorlnator off-gas 2.0* 30,000* Discharge to Waste Disposal 1. Montar 2. Aroclor 0.0176* 0.33* 5,000* 95,000* Estimated HONS 047831 Dept, 846 - Process Description 37. AROCLOR APPENDIX I PROCESS CONTROL Sampling Point Frequency Reason for Normal Sample Range Method Number Chlorinators 2-3 times per batch Specific Gravity .011 Blend Tanks Storage Tank Composite Tank Cars & Trailers 3 times eaoh day Every 1-2 days Color (APHA) 50-150 Max. Sp.Qr. at 25/15.5C .011 Acidity (mg.KOR/g.) .014 Max. Moisture (HpO) (PPM) 35 PPM Max. Refractive Index at 25C .0020 Inorganic(freeJChlorides .05 PPM Max. Dielectric Constant .20 Resistivity (500 VDC 0 100C 500, Min. 0.1" OAF as ohm-cm x 109 Hydrolysis Stability 1.0 PPM Test (as Chlorides) Max. Monsanto Stability 0.5 PPM Test (as: Chlorides) Max. Sulfates None Dielectric Strength at 25C 35 KV Min. Viscosity at 100F (sus) 10 Thermal Chemical 0.75 PPM Chlorides Max. Same as blend tanks Every Load Same as blend tanks 10,084 10,114 10,087 10,620 10,125 T-2092 11,608 11,607 T-2087 11,503 12,169 11,605 10,086 12,722 HONS 047832 Testa made on electrical grade Aroclors only. . Tests made on request only. Special oustomer test. Maximum range for all Aroclors Including electrical and non-electrlcal grade s. Dept. 246 - Propose Description 38. AROCLOR APPENDIX J SAFETY AND TOXICITY DATA SAFETY EQUIPMENT The following is a list of safety equipment (personal and departmental) required in department 246. 1, Fire extlrigulBhers: A. Dry Chemical (3) - Southwest corner Bldg. CR - Main Floor - West wall at top of Btairs of second floor. B. Carbon Dioxide Snow - Southwest corner of Bldg. CR, ground level. 2. Chlorine Qas Masks(4) - Southwest oorner, second floor - Control room, second floor ( - East side, outside control room - Wall, Southwest corner of sprinkler house, main floor. 3. Scott Air Masks - West of Lean-To 4. Safety Showers (2) - Southeast corner of Bldg. CR, ground level. - Southeast corner of Bldg. CR, 2nd floor. 5. DaviB Vapotester 6. Eye Baths 7. Sprinkler System Safety Precautions The following are safety precautions followed in the operation of department 246. 1. Safety Equipment of Employee Each employee haB the following safety equipment: (l) hard hat ( (2) safety glasses (3) goggles (4) rubber and canvaB gloves (5) rubber overshoes. Special equipment may be Issued as necessary for performing a particular Job in a safe manner. HONS 047833 I Dept, 246 - process Description 39. AROCLOR APPENDIX J SAFETY & TOXICITY DATA (Cont'd.) 2. Sampling of Crude Aroolor The earnpie8 of Aroclor taken during the chlorination reaction are hot (170C). Precaution must be taken to avoid Bkin contact of sampleB and inhalation of hydrogen chloride, chlorine and aroclor vapors. 3. Fires Fires may result from the ignition of leaking gas, xylene, diphenyl, rags, paper, wood, etc. Automatic fire extinguishers and sprinklers have been installed to combat fires. 4. Explosions Explosions may be caused from accumulated pockets of natural gaB or a rapid burning of Diphenyl in a oloBed container such as a ohlorinator. Chlorinators are equipped with a 10" diameter pressure relief line with a rupture disc madeto buret at 22 psi in case diphenyl within the chlorlnator ignites. 5. Toxicity Toxicity does not present a serious problem. However, a com ( plete dally change of clean clothes iB supplied to each person and time is allotted at the end of each Bhlft to take a bath. Instructions are also Issued to avoid actual skin contact with Biphenyl and Aroclor as much as possible and to wash hands and faoe before eating. 6. Miscellaneous There are many accidents that can occur that may be classified as health and safety hazards. These accidents may result from such things bb broken process lines, acid leaks, steam leaks, etc. The worst inherent hazards are as follows: 1. Free chlorine from ruptured line or major leak. 2. HC1 gas from ruptured line or major leak. 3. Dropping bottoms from Btllls. 5. Hot aroclor and diphenyl. Safety Record The last loBt-time injury in Department 246 was January 28, 1948. The frequency of minor injuries 1b low, around one per month. Toxicity: ThiB material is a liquid under normal conditions and has a medium toxicity range for liquid ingestion and high toxicity for vapor ( inhalation. The maximum allowable concentration (M.A,C.) is 1 mg/cubic meter. Fire Hazard: There 1b no fire hazard under normal conditions. Aroclor mixes (Xylene, Toluene, Butyl Acetate, etc.) may burn and explode at high temperatures when exposed to flames. MONS 047834 Dept, 246 - Process Description AROCLOR APPENDIX J SAFETY & TOXICITY DATA (Cont'd.) 4o. Other Hazards: This material can cauBe dermatitis, systemic poisoning from the fumes, and yellow atrophy of the liver. There are skin, mucous membranes and eye hazards encountered in handling this material. Treatment and Antidotes: Call a physician and remove patient from fumes. Storage and Handling! Proteot the skin, lungs, and eyes by wearing approved protective clothing, respirator, and goggles. People who handle this material at elevated temperatures should have medical supervision, and the air should be sampled to Insure compliance with H.A.C. There are no special storage restrictions under normal conditions except store in a ventilated area. Shipping: There are no speolal shipping restrictions, FERRIC CHLOftlDE (FeC^) Toxicity: This material is a solid under normal conditions and is nontoxlo or has a rating as low. Fire Hazard: There is no fire hazard under normal conditions, but it will emit toxic fumes at high temperatures. Other Hazards: Some people are allergic to this material and may develop skin rash, and there is an eye hazard. Treatment and Antidotes: Call a physician. Storage and Handling: Protect the skin with approved protective clothing, avoid the breathing of FeCl3 dust, wear approved respirator with adequate cartridge, and proteot the eyes with approved goggles. There are no Btorage regulations. Shipping: There are no shipping restrictions. DIPHENYL (CgH5CgH5) Toxicity: This material is a solid at normal conditions and 1b medium toxic. The M.A.C. of vapor is a 2 mg/cubic meter of air. If Ingested, the lethal dose is 2.4 g/iCg of body weight. The fumes are not dangerouBl deadly, but they are poiBonous over a prolonged time. Fire Hazard: Diphenyl is very flammable and will burn when exposed to heat ol' flame or oxidizing materials (F.F. - 120C). Other Hazards: Diphenyl is not too corrosive to skin, but it will affect the eyes. MOWS 047835 c I () I I (' Dept. 246 - Process Description 4i. AROCLOR APPENDIX J SAFETY & TOXICITY DATA (Cont'd.) DIPHENYL (CsHjCgHj) (Cont'd.) Treatment and Antidotes: Wash eyes with water and set the patient to fresh air. TryTTo get patient to vomit, and call a physician. Storage and Handling; This material can be stored In steel containers away from l'lre hazards and oxidizing agentB. Wear suitable clothes and approved goggles when handling diphenyl. Shipping: Ship In cars or other suitable containers with a red warning label of flammability. XYLENE (C6H4(CH3)2 Toxicity: This material Is a liquid under normal conditions and Is very toxic in liquid or gaseous form, but it Is less toxic than toluene. The H.A.C. Is 200 ppm. Fire Hazard: This material is very flammable and the limiting explosive concentration is 1-5.3# by volume in air. It will also react with oxidizing agents (F.P. -85F). Other Hazards: This material will cause necrosis if enough is Inhaled, and is hazardous to eyes, mucous membranes, and the skin. Treatment and Antidotes: Get patient to fresh air, and call a physician. Tf injested, get patient to vomit. Wash eyes and skin with water. Storage and Handling: This material should be stored in a cool wellventilated area away from fire hazards or Btrong oxidizing agents. The material for storage can be steel oars or tanks. Wear approved protective clothing, respirator, and goggleB. Shipping: Ship in containers of steel or appropriate material with a red label. TRICHLOROBENZENE: Toxioity: This material is a BOlid at room temperature and the vapors are quite toxic. The solid is poison if ingested. The M.A.C. is 50 ppm. Fire Hazard: This solid 1b flammable but is listed only as a moderate fire hazard. Will burn at 420C or above. Other Hazards: This material will affect the liver, eyes, and mucous membrane s. Treatment and Antidotes: Wash eyes with water, and get patient to fresh air. Call a physician. HONS 047836 ( Dept. - Process Description 1)2. AROCLOR APPENDIX J SAFETY & TOXICITY DATA (Con) THICHLOROBENZENE (Cont'd.) Storage and Handling: Store thiB material In cool, well-ventilated area away f'rqm hazards and oxidizing agents. Wear protective clothing, chemical safe goggles and approved respirator. Shipping: Ship in steel containers like cars or tanks with red label. TETRA-TRI-CHLOROBENZENE Toxicity: This material is a solid at normal temperatures and is medium toxic. The M.A.C. of vapor Is 50-75 ppm. Fire Hazard: This material is not a very great fire hazard, but It will Burn at high temperatures and will decompose and emit chlorine. Other Hazards: This material will affect the eyes, skin, and mucous membranes. ) Treatment and Handling: Wash eyes and skin with water and get patient to rresh air. Call a physician. Storage and Handling: Store this material in a cool place away from fire hazards and strong oxidizing agents. This material can be stored in steel cars, tanks, or etc. Wear protective clothing, approved respirator, and chemical safe goggles when handling thlB material. Shipping: Ship this material In containers marked with a red label. UME Ca(0H)2 Toxicity: Lime Is not dangerously toxic, and it is regarded as more of a nuisance. This material Is a solid or slurry. Fire Hazard: This material is not flammable. Other Hazards: Lime 1b very hazardous to the eyes. It will burn the skin also, and the dust will affect the mucous membranes. Treatment and Antidotes: Flood eyes and skin with large quantities of water. If lime is Ingested, get patient to vomit and call physician. Storage and Handling: Lime can be stored in steel containers, anl people should wear (protective clothing, respirators, and rubber or chemical safe ( goggles when handling lime. t Shipping: There are no special restrictions for shipping, but the containers should have a white label, a caustic warning. HONS 0A7837 l Dept. 46 - Process Description AHOCLOR APPENDIX J SAFETY AND TOXICITY DATA (Cont'd.) ATTAPUIflUS EARTH Toxicity: This earth Is not toxic In general. Fire Hazard; There Is no fire hazard. Other Hazards: Attapulgus earth can create a dust hazard similar to other dusts that contain silica. Treatment and Antidotes: Consult a physician. Storage and Handling; Attapulgus earth presents no speolal storage problem and should Be handling by persons wearing an approved respirator. Shipping: There are no special restrictions on shipping. HYDROaBN CHLORIDE (HC1) Toxicity: This material is a gas under normal conditions and Is very ( Toxic. The M.A.C. Is 5-10 ppm and a concentration of 1500-2000 ppm would be fatal to humans In a few minutes. Fire Hazard; There Is no fire hazard under normal conditions, but wet gas reacts with some metals to form hazardous hydrogen. Other Hazards: This material Is hazardous to teeth, skin, eyes, and mucous membranes. Treatment and Antidotes: WaBh profusely with water. If Ingested, eat chalk, magnesium hydroxide, egg whites, and milk, and also administer oxygen. Call a physician. Storage and Handling: This material should be stored In a cool, well ventilated area away from oxidizing agents. This material can be stored In rubber lined, glass, or tantalum vessels. People handling this material should wear suitable clothing like rubber aprons, shoes, and gloveB. Also rubber goggles or chemical safe grades and approved pack or canister gas masks. Shipping: Shipping containers must have a white warning label and a non-flammable label. Ship In appropriate containers Buoh as rail car or carboy. CHLORINE (CI2) ^ Toxicity: This material Is a gas under normal conditions and 1b very toxio. The M.A.C. Is .35 to 2 ppm. A concentration of 1000 ppm would be rapidly fatal. Least concentration with detectable odor Is 3-5 ppm. MGNS 047838 Dept, 2A6 - pfoceBS Description AROCLOR APPENDIX J SAFETY & TOXICITY DATA (Cont'd.) CHLORINE (CI2) (Cont'd.) Fire Hazard: There 1b no fire hazard under normal conditions, but there 1b an explosion hazard if chlorine is mixed with a strong reducing agent such as hydrogen or hydrocarbons on high temperature. Other Hazards: This material causes eye, skin, and mucous membrane Trritation. Treatment and Antidotes: The patient should be given oxygen immediately and treated for shock. Call,a physician. Storage and Handling; This material should be stored in a ventilated and cool plaoe away from fire hazards. When handling, wear a gas mask or approved respirator, clothing and rubber or chemical safe goggles. In strong chlorine concentrations, wear canister gas masks, Scott Air Pack, or oxygen breathing apparatus. Shipping: The Bhipping containers must have a green gas label and a non-flammable label on. Ship In steel cars or cylinders. MUNS 047839 Dept. 46 - Process Description AROCI/OR APPENDIX K BACKGROUND INFORMATION 45. The manufacture of Aroolore was developed quite by ohanoe. The Indian Refining Company, in the latter part of 1926, approached the Swann Chemical Company located in Anniston, Alabama, regarding the production of Biphenyl which the Indian Refining Company wanted to use as a heat transfer medium. The Swann Chemical Company agreed to produce Biphenyl, but first a process had to be/developed. Two years later, in 1928, a pilot plant for producing Biphenyl became operative. However, in the meantime, the Indian Refining Company dropped all interest in Biphenyl. Since a process had been developed for manufacturing Biphenyl, the Swann Chemloal Company started looking for other outlets for this material. The simplest outlet was in the form of Chlorinated Biphenyls which were produced In the laboratory in 1929. The Chlorinated Biphenyls produoed exhibited good electrical proper ties. This was reported to the General Electric Company who Immediately became interested In the product which ultimately developed into large scale consumption in electrical transformers and capaoitors. The trade name "Aroolors" was adopted for the Chlorinated Biphenyl products. The properties of Aroclors vary from mobile oily liquids to fine white crystals and hard transparent resins. The excellent electrical properties, fire resistance and inertness of the Aroclors make them useful for many applications. Plant equipment was installed to produce Aroclors at a rate of 3000 pounds per day or 1 million pounds per year. In the following years, this production rate was insufficient to meet the increases sales requirements. The Swann Chemical Company was purchased by the Monsanto Company in 1935. This purchase gave Monsanto access to the patent rights for the production of Aroclors. Production capacity needed to be expanded, and since Monsanto had a chlorine plant bb "Plant B" (now called the W. 0. Krummrieh Plant), the Aroclor production was transferred from the Anniston Plant to the Monsanto, Illinois Plant, where operations at an increased productive oapaoity started in September, 1936. By 1940, the Krummrieh Plant production capacity was inadequate, and in 1941, a similar production unit was installed in the Anniston Plant. MQNS 047840 Dept. 46 - Process Description ' AROCLOR APPENDIX L TIME CYCLE The design capacity of the department is 2,400,000 pounds per month or 88,800,000 pounds per year. Figure 1 of this section illustrates the flow pattern of the Aroclor process and 11Bts the approximate time needed to complete each process step. The time table for the Aroclor process is summarized below: Operation Time (hours) Equivalent pounds of Finished Product Charge Chlorinator Chlorination 1248 1248 1254 1260 Transfer to blow tanks Aeration DlBti nation 1248 1248 1254 1260 Blending Filtering Dropping to Storage .25 6.00 8.00 10.00 12.00 .25 2.00 1.75 1.75 1.75 1.75 2.00 2.00 2.00 6400 7200 8o4o 9100 The time required to make completed batches of the various Aroclors are tabulated below: Aroolor T2$2 1248 1254 1260 Batch Time (hrs.) -------17725----18.25 20.25 21.25 Process operations including filter press cleaning, sampling, etc., are Independent of the batch completion time cycle because production time is not lost. MONS 047841 Dept. 246 - Process Description 47. AROCLOR APPENDIX M QUALITY CONSIDERATIONS The Aroclor compounds are among the most versatile chemically-made materials In Industry. Aroclors are useful In many ways because of their outstanding inertness. Aroclors are used alone for particular physical Jobs such as insulating, heat transfer, sealants, and expansion media; and they are used as components or extendors in elastomers, adhesives, paints, lacquerb, varnishes, pigments and waxes. AroclorB must be highly pure, with dependably minimal traces of electrolytes for use in electrical applications. Electrical grade Aroclors must pass numerous stringent specifications. The following tests determine Aroclor quality: Hydrolysis Stability Measure of chemically unstable chlorine compounds. Munch or Monsanto Stability Test Measure of thermally unstable chlorine compounds at elevated temperatures. Thermal Chemical Chloride Developed by the General Electric Company to measure chemically and thermally unstable chlorine compounds. Resistivity Measure of insulative properties. Power Factor Measures power loss due to current through a capacitor. Dielectric Constant Measures the capacitance of a Btandard such as air compared to the capacitances of Aroclor. Speoifio Oravity, Refractive Index Measures of chlorination level. The stability and electrical properties of electrical-grade Aroclors are paramount in quality considerations. The chlorination step of the process is most critical because many properties of the final product are determined by the properties of the crude Aroclor. Conditions In the ohlorlnator needed for a good quality product are: 1. Chlorination Temperature - The chlorination temperature must be greater than 120UC wlthin 30 minutes from the beginning of the ohlorlnation reaction to produce stable Aroclors. Results of research tests indicate that product stability Is better sb the initial chlorination temperature is increased. HONS 047842 Dept. g<l6 - Process Description H8. ( APPENDIX M QUALITY CONSIDERATIONS (Cont'd.) 2. Ferric Chloride Concentration - Research has found that the femo ohloride concentration must be at least 0.03^ to fomi stable products. Research recommends 0.05% ferric chloride. Lower catalyst ratios result in Increased "addition" chlorina tion as opposed to "substitution" chlorination, indicated by higher ohloride values and lower yields. The isomeric distribution of the final product 1b a function of the type and concentration of the oatalyst used in the reaction. Homogeneous suspension of the catalyst is extremely important. Good catalyst contact cannot be attained without homogeneous suspension. Since ferric chloride does not mix well with biphenyl, the dry catalyst must not be poured into the chlorinator. 3. Geometry of Reacting Vessel - The shape of the reactor affects the 'circulation and flow pattern of the reactants. It is suspected that the chlorine gas channels through a void space in the existing catalyst basket. This problem is presently being studied. The reactor must be designed such that circulation of reactants is rapid and homogeneous and local over-chlorination does not ( occur. 4. Cleanliness - The ferric chloride settles to the bottom of the chlorinator. Areas of the packed bed become plugged with ferric chloride and channeling of reactant flow may result. A steam clean-out of the ohlorinator may be an expedient mo the' to remove the ferric chloride. This method waB tried in th department, and evidently was successful. Further tests by the laboratory will verify the effectiveness of a steam clean out. 5. Sparging - The sparger controls the gas distribution under the catalyst hold-up plate and the size of gas bubbles. It is riot known whether the catalyst basket or sparger or both are the critical factors in achieving the proper flow of gas through the reactor. It is believed that the sparger should distribute Bmall bubbles giving good gas distribution throughout the chlorinator. The small bubbles have a greater surface area per unit volume of gas for mass transfer and this should increase the reaction rate. HONS 0 4 7 8 4 3 6. Raw Material Purity - The purity of raw materials can affect the quality of Aroclors. Sulfates are particularly harmful in the chlorine gas. It is suspected that sulfates poison the ferric chloride oatalyst and sulfates some of the biphenyl. If the ferric ohloride oatalyst is poisoned, the effective catalyst concentration is reduced and thus unstable aroclors will be produced. The chemistry and mechanlBm of catalytic poisoning are not known for certain. Sulfonated biphenyl is carried over during distillation and Ib not removed by earth treating. Dept. 246 - ProcesB Description AROCLOR ATONDIX M QUALITY CONSIDERATIONS (Cont'd.) 6. Raw Material Purity (Cont'd.) Sulfonated biphenyl has ionic properties which lowers the resistivity of the finished product. A Brink MlBt Eliminator has been installed in Dept. 246 to eliminate the chlorine impurities. 7. Earth Treatment - The factors affecting stability also in fluence the electrical properties of Aroclors. An absorbent will be ineffective if the Aroclor waB not prepared in a manner such that a stable product was formed during the chlorination reaction. However, research has found that absorbents are very effective for improvement of electrical properties by removing ferric chloride and tars carried over during distillation, provided the crude Aroclor has good stability. The absorbent used in Dept. 246 (after distillation) is Attapulgus Earth, the concentration should be 0.5# for Aroclor 1242 and 0.1# for other Aroclors. The earth muBt be heat treated at 250C for a minimum of 4 hours before addition to the Aroclor. Heat treatment reduces the moisture and activates the earth. 8. Lime Treatment - It is important that proper amount of lime (250 founds per still run) be added to the still to prevent sublimation of ferric chloride. 9. The blend tanks, finished product tanks, and Aroclor 1242 and 1254 Btorage tanks are blanketed with nitrogen gas. Nitrogen blanketing maintains the electrical properties of the Aroclors by preventing corrosion of the equipment. In summary, the chlorination step of the process is the most critical. A good quality Aroclor cannot be produced if a stabl compound is not formed during chlorination. Once a Btable compound is formed, other techniques such as use of lime, absorbents, and nitrogen blanketing are used to maintain and Improve electrical properties. MONS 047844 50. Dept, 246 - FroceBs Description AHOCIOR APPENDIX M QUALITY CONSIDERATIONS (Cont'd) Absorbents - Numerous absorbents have been screened in the laboratory at various contact temperatures for their effect on resistivity of plant untreated Aroclor 1242. The most satisfactory absorbent pound for improving the resistivity of Aroclor 1242 was LVM attasorb. Table I of this section liBts the laboratory results of the different absorbents used to treat Aroclor 1242. Degradation of Aroclors Degradation of Aroclors, which leads to loss in electrical resist ivity, is one of the short comings of using Aroclor as a dielectric expeclally Bince only a very minor degradation can cause a serious breakdown in electrical equipment. The thermal degradation of fractionated Aroclor has been measured at 250C and the amount of Hydrogen Chloride liberated was measured The results of these teBts are listed in table II of this section. Aroclor 1242 has been degraded by ultravlolent light, and the decrease in electrical resistivity with irradiation time was measured. The plot of resistivity versus concentration is a curve for a weak electrolyte. It is possible to remove the conducting material brought about by photo-degradation, and restore the resistivity of its original value by passing the degraded material over activated alumina. Thermal degradation of Aroclors is minor compared to photo chemical degradation. Thermal treatment causes release of a small amount of hydrogen chloride initially, but this evolution ceases after a short time. Such behavior 1b attributed to thermal degradation of Impurities. If Aroclor is irradiated, then exposed to a thermal treatment, appreciably more HC1 is liberated. HONS 047845 Dept, gil6 - Process Description AKOCLOR APPENDIX M QUALITY CONSIDERATIONS (Cont'd.) 51. TABLE I ADSORBENT SCREENINQ DATA Adsorbent Adsorbent Pretreatment Contact Temperature C LVM Attapulgus Earth LVM Attapulgus Earth IMV Attapulgus Earth LVM Attapulgus Earth AttaBorb - LVM None Heated at 250C 12 Hours Heated at 350C 12 hours Heated at 350C 4 hours None Attaclay None Activated Alumina (Alcoa Orade P-3 -325 mesh) None Voclay 325 (Western Bentonite) Panther Creek (Southern Bentonite) Plltrol Qrade 1 Zeolex 7 (Zeolite) Florlte 60 mesh (Activated Bauxite) Suprex L-Q (Kaolin) Attasorb - LVM Attasorb - RVM None None None None None None Heated 35 CPC 12 hours None 60 80 100 120 60 80 100 120 60 80 100 120 60 80 100 120 60 80 100 120 80 100 120 60 80 100 120 80 100 120 80 100 120 80 80 100 100 100 100 . Volume Resistivity at 100 ohm-cm. x 10C 3400 2000 2800 2900 4200 6400 7200 6100 9300 9000 6300 6300 2400 5600 6000 5700 9700 12,100 13,700 17,800 10,200 5400 6000 2100 2500 2800 3100 5700 3800 9700 6200 11,300 8100 2600 7000 3600 4500 12,200 16,200 HONS 0 4 7 8 4 6 ( Dept, 246 - process Description 52. AROCLQR APPENDIX M QUALITY CONSIDERATIONS (Cont'd.) AdBorbent TABLE I (Cont'd.) Adsorbent Pretreatment Contact Temperature C Volume Resistivity at 100' ohm-cm. x : Linde Molecular Sieve Type 4-A None 6o 2100 Laminar Alumina None 60 900 ( Note: Reslsvitlty of Aroclor before treatment 1 x 10^ ohm-om. ( MONS Dept. 24G - Process Description AROCLOR APPENDIX M QUALITY CONSIDERATIONS (Cont TABLE 11 THERMAL DEGRADATION OF AROCLORS AT 250C Aroclor 1221 1232 1242 1248 1254 Bra. of HCl/sm x 106 3.35 6.73 11.07 3-?l 6.42 9.81 5.96 9.58 13.00 3.61 5.44 8.48 3.43 3.96 6.43 Heatlrw Time 1 hr. 2 hrs. 5 Krs. 1 hr. 2 hrs. 5 hrB. 1 hr. 2 hrB. 5 hrs. 1 hr. 2 hrs. 5 hrs. 1 hr. 2 hrs. 5 hrs. 53 ( HONS 0*7840 Dejg^^S^^^PrpceBsJDesorlgtlon AROCIiOR APPENDIX N MISCELLANEOUS REFERENCES 1. St. Louis Report No. 2694, Job No. 171-1028, February 15, 1952. Title: Operation of Aroojor Stills At Increased Pressure For Increased RatcB Summary: Distillation runs were made at 20 to 30 mm Hg. The rate of distillation of 1200 series Aroelors Increases with pressure, 2. St. Louis Report No. 2755, Job No. 2-02-760.01 - 3948-3 March 6, 1961. Title: Improved Aroclor 1242 Studies Summary: Studies were carried out to determine the effect of temperature, chlorine content, and catalyst concen tration In chlorinated biphenyl mixtures. 2,4-dichloroblphenyl Is the peroursor of the high dielectric constant, trlchlorinated components. 3. St. Louis Report No. 2072, Job No. 2-02-750.01-3428, May 4, 1958. Title: Final Report on Aroclor Process Studies. Summary: Purity of raw materials, catalyst concentration, reaction temperature and rate of chlorination were the variables studies with respect to their Influence on the stability of the finished product. 4. St. Louis Report No. 2540, Job No. 171-616, December 28, 1958. Title: The Effect of Prolonged Heat on the Electrical Properties of Aroolors. Summary: AroclorB 1232, 1242, 1248 and 1254 were held at 130C. The power factor was periodically measured. 5. St. Louis Report No. 2234, Job No. 171-451, June 14, 1956. Title: Evaporation Loss of Aroelors. Summary: The evaporation Iobs of Aroelors was determined at 100C under static conditions. MONS 047849 Dept. 246 - Process Description AROCLOR ~ APPENDIX N MISCELLANEOUS (Cont1d.) REFERENCES (Cont'd.) I / / / / / 55. , ' 6. St. Louis Report No. 2790, Job No. 171-1028, July 3, 1952. Title: Increased Producti:n of Aroclors by More Rapid Rate of Chlorination. Summary: Chlorination rate was increased from 400 pounds per hour to 770 pounds per hour. Aroclors produced at increased rate was within specifications. 7. St. Louis Report No. 1842, Job No. 2-02-750.01-3368 July 12, 1957. Title: Use of Ferric Chloride as Catalyst for Production of Aroclor 1242. Summary: The comparison of stability chloride valueB revealed no difference between the product made with iron turnings as catalyst and ferric chloride as catalyst. 8. St. Louis Report No. 2096, Job No. 2-02-750.01-3202, June 6, 1958. Title: Resislstivlty Improvement of Aroclor 1242, Summary: Numerous absorbents were screened at various contact temperatures for their effect on resistivity of plant untreated Aroclor 1242. Heat activation of AttapulguB Earth was also studied. 9. E. E. Martin, OPERATING INSTRUCTIONS FOR DEPT. 246. W. Q. Krummrlch Plant, I96TT" ` 10. E. E. Martin, PROCESS DESCRIPTION FOR MANUFACTURE of aroclors. 155?;; ^ 11. E. Mather, PROCESS DESCRIPTION FOR MANUFACTURE OF AROCLORS. 15W. MONS 047050 Dept, 246 - Process Description AROCLOR APPENDIX N MISCELLANEOUS The following table shows the results of tests which measured the evaporation losses of the various Aroclors. Aroclor Evaporation Rate gms/om2/hr./100C Aroclor 1221 .00174 Aroclor 1232 .000874 Aroclor 1242 .000338 Aroolor 1248 .000152 Aroclor 1254 .000053 Aroclor 1260 .0000088 Aroclor 1262 .0000132 Prom the above results, the evaporation rate for Aroclor 1262 is greater than that of Aroclor 1260. This unexpected result may be explained by some difference in the conditions of which the two lots were prepared. The reaction products in Biphenyl Chlorination differ with the type of oatalyst used. Results of research investigations are listed belows Catalyst Pe C3o 3b Clo Ti CI5 Sn Clj| Isomer Distribution of Aroclor 1232 2- 'i'i' * 2,4 - gll.'. - '4,4' 15* 11 11 24 7# 0.7 0 1 15* 20 20 16 6* 3.6 2.2 2.3 3856 38 46 38 11# 18 14 18 trX 9% 9 7 1.3 HONS 047851 57. Dopt. 246 - Process Description AROCLOR APPENDIX N MISCELLANEOUS (Cont'd.) Some of the typical operating difficulties in department 246 and possible remedies are given below: CHLORINATORS Trouble Cause Remedy Chlorlnators operating against too much back pressure Plugged off-gas lines Open lines and steam them out. Dry out lines with air before resuming operation. Chlorinator slow in 1. Low chlorine 1. Call chlorine picking up gravity pressure or low dept, for more chlorine gas gas concentration 2. Check biphenyl 2. Wet biphenyl storage tanks for l moisture. BLOW TANKS Blow tanks stacking off Operating chlorlnators with vent open Close chlorinator vent; possibly re duce air to blow tanks STILLS Not enough vacuum 1. Ejectors not pull ing properly 2. Coke scrubber contains water 1. Check ejectors 2. Drain coke sorubber 36" SPARKLER FILTER Foreign material in filtrate samples Dirty filter or broken paper Clean and re-paper press (~ HONS 047852