Document EqEV3KneoaOok2M9bkve4xwwn
MQNS
PROCESS DESCRIPTION FOR THE MANUFACTURE OF AROCLORS
MONSANTO COMPANY Monsanto, Illinois
Messrs: P. P. Hcislcr H. C. Carder M. K. Gibbs - Oi^g. Res. II, 1,. Hubbard - Org. Res. Process Holders
September 20, 1966 Tentative Amendment No. "K"
TI'JHK
Tentative Amendment No. MFH to the Standard Manufacturing Process for Aroclor (Dept. 246 - WGK) dated 7/20/64.
ODJKCTJVK
Produce improved quality Aroclor with activated bauxite (A12Oj) treatment .
PKFSKNT FRACTION
Distilled Aroclor is treated with activated attapulgus clay for quality up-grading in one of two earth treating tanks followed by filtration to remove suspended solids before storage.
PROPOSK1J PKpCf:DUKK
Substitute clay with "poroccl", activated bauxite supplied by Minerals and Chemical Corp. , at levels sufficient to evaluate up-grading per formance. Poroccl (20/60 and 4 60 mesh) suspended with agitation and recirculation in the existing earth treating system. Treated Aroclor will be filtered to remove suspended solids before storage.
JUS'i'IKlCAlTO^N
'
Anniston personnel have demonstrated (sec Report 370- 322-9 byJ.G. Bryant) exceptional up-grading performance in the laboratory by circulating Aroclor 1242 through a packed bauxite bed. Reported per formance is summarized below:
Specification
Present Up-grading Performance @ Anniston........ .....
Bauxite l*b. Treating Pcrformanc e
Resistivity (x 10%mm-cm) Power Factor () lOO^C 8* 1 KC
<6? 1 00*C & 60 cps Tbcrm.tl Chemical Chlorides, ppm Wcstinghousc Stability, ppm Hydrolysis Stability, ppm
900
0. 2 2. 0
0. 3 0.7 0.2
44.000 0. 02 * 0. 03 * 0.07 0.18 0. 04
* Kxcecding Sensitivity of Measuring Instrument.
HONS 047761
2
JUS'J JKICATION (Conl'd. )
Monsanto can very economically defend its unique marketing position if such performance can be demonstrated on a plant scale.
TIMING
This amendment will be initiated after Anniston has successfully demonstrated a similar amendment and at time consistent with normal production schedules,
SAJ-KTV
Aluminum oxides have been in contact with Aroclors for more than two years in storage units with no difficulties. Because of this, and laboratory work with bauxite treatment, present safety considerations are believed to be adequate.
KXTKNT Op l>?.-MONSTRATipN.
Up to 40 batches of Aroclor 1242 (2, 000 gal. /batch) will be processed resulting in a maximum of 800, 000 lbs. of product which will be used in non-electrical applications.
Prepared by: Cliff Woodward
Reviewed By:
Approved By:
^ ___ ......................................................................./O'U-66
J)iv, Rcsca rch Group Deader Date
Production Supervisor
Date
^ L /rv.:- A
/ci,-
.. /o/,.uc
Mgr. of Research
' J Prod. Gen. Superintendent Date
Research Safely Review Committee
$ 0 0/v\n . Tut/ !
/of/g/H,
PI. Process Res. Grc$p Lcador'Dale
y?5 Gen.
.... Tech. Servicing
Dale
i /> / > ../' /Djf-Sfa
Technical Production Manager "Date
HONS 047762
MONSANTO COMPANY ORGANIC CHEMICALS DIVISION
STANDARD MANUFACTURING PROCKSS FOR AROCLORS - DEPARTMENT 246
Supersedes: Standard Manufacturing Process for the Manufacture of Aroclors, Department 246 Dated July 20, 1964 and all amendments.
Trcpared by:
D. E. Harris
Approved by:
_S "General Superintendent
fiesearch ^cTrhfca^^o^ci3on' \FecTm
Date: /o/t,k af
COPY
in of
This process is the property of Monsanto Company and the recipient Is responsible for its safekeeping. It contains confidential Information of Monsanto Company which must not be reproduced, revealed to unauthorized persons or sent outside the company without proper authorization. Either retain in a secure file or return to the Standard Documents Dept.
HONS 047763
(
DJ STRIBUTION SHEET
1. Technical Information Center 2. Technical Information Center 3. Central Reports f|, Technical Production Manager i). Production General Superintendent 6. production Supervisor 7. TS1) Group leader 8. Plant Research 9. Id brary 10. Extra 11. Extra 1?. Extra 13. Extra 3 It. Danna 13. Danna
(
HONS 047764
AMKNDING RECORD SHKKT MONS 047765
( TABIK OK CONTENTS
INDEX
SECTION I
SYNOPSIS OK PROCESS
SECT]ON 13
F1.0W SHEETS
A CHICHINATION REACTION STEP B. AERATION AND D1STIIJ.AT10N
0. B).ENDING, FILTRATION AND STORAGE
SECTION 111
PROCESS IN DETAIL A. NOMENCIATURE AND BATCH DATA B. CHI.ORINAT] ON REACTION STEP C. AERATION AND DIST1LIAT10N D. BI.END1NO, FILTRATION AND STORAGE
E. BY-PRODUCT HYDROGEN CHIORIDE
Section iv
{ APPENDIX A
comments on process
A. CHLORINATION STEP B. AERATION & DISTILLATION C. BLENDING & FILTRATION D. GENERAL
EQUIPMENT LIST
APPENDIX B
FINISHED GOODS AND RAW MATER]All SPECIFICATIONS
APPJiNDIX C
PHYSI CAL AND CHEM] CAI, DATA
APPEND!X D
UTILITIES
APPENDIX E
PERSONNEL
APPENDIX F
PACKAGING AND SHIPPING
APPENDIX Q APPENDIX H
MATER] AI, BAIANCE
ATMOSPHERIC DISCHARGE AND WASTE DISPOSAL
APPKND1X I APPENDIX J
PROCESS CONTROL PROCEDURES SAFETY AND TOXICITY DATA
APPEND!X K
BACKGROUND INFORMATION
APPENDIX I,
time: cycles
APPENDIX M
QUALITY CONSIDERATIONS
APPENDIX N
MI SCELLANKOUS
HONS 047766
PAGK ?
3 3A 3H 3C
U 5 -6 7 7-8 8
9-13 II 1?
13-21 ??'
23 ?3|-?0 29-30
31-3? 33-33 36
37 38-3)3) 3)9 H6 3)7-93 53)-57
(
llcpt. ?^6 - Frocess poser! ptl on
i.
AHOCljOH
SKCT1 ON 3
SYNOFSJS OP PROCESS
Aroclor 1e a trade name used to designate chlorination products of biphenyl, biphenyl high boilers, or mixtures of the two. liquid Aroclors are produced by chlorinating biphenyl to 21, 32, k?, h0, 6*1, 60, and 62<f> chlorine content. Chlorination above 63St yields a solid product at norma] temperatures. Liquid Aroclors are Identified by four digit numbers; The last two digit numbers represent the chlorine content (percentage by weight), and the first two numbers represent the Aroclor condition (crude or distilled). Crude Aroclors start with the prefix 11 whereas distilled Aroclors start with the prefix 12. For example, Aroclor 121)2 Is a distilled chlorinated Diphenyl containing 1)2JS chlorine.
The first process step In tte manufacture of AroclorB Is a chlorina
tion reaction. Biphenyl ( 0-0) and chlorine (Cl?) gas In.the
presence of a Ferric Chloride (FeClj) catalyst are reacted to form
a chlorinated aromatic compound. Hydrogen chloride (HC1) gas Is
liberated during this reaction and piped to the muriatic acid department. The exact chemistry of biphenyl chlorination Is unknown. Many Isomers are formed. A schematic represcntatlon of
biphenyl chlorination Is as follows;
B1IHKNYI. M.W. * 15*1
CH1.0R1 NB M.W. * 71
AR0C1.0H
M.W .= (26*1.1396.6)
HYDHOGKN CHLOHIPK M.W.-; 36.6
HONS 047767
Dept. 246 - Process Description
AROCl.OR
SKCT'3 01l_l
SYNOPSIS .OKJWtOCKSS (Cont'd.)
The second prooess step 1b the aeration and distillation of the crude
Aroclor. Dry air Is blown through the crude Aroclor for a period of
two hours or more. Aeration removes most of the free hydrogen
chloride. Distillation of crude AroclorB 1b done under vacuum auto
matically controlled with the controller pre-set between 30-50 mm Hg.
age. to obtain the best performance. Distillation of crude Aroclor
separates residue, lime, ferric chloride, and tars from the finished
product.
The third.process step Includes blending, filtration, and storage of AroclorB. Approximately 0.1 - 0.2# by weight of Attapulgus earth Is added to the distilled Aroclor. The mixture Is agitated and filtered to the finished product tank. The purpose of the Attapulgus earth ., Is to absorb moisture and chloride Ion to Improve the electrical properties of the Aroclor. During the filtration of distilled
Aroclor, 2 - 16 or,, samples of the finished product are taken to the laboratory for control analyses. If the control analyses pass specifications, the batoh is transferred to a storage tank.
This process description will describe the production of Aroclors 1242, 1248, 1254, 1260, 1254 xylene mix, and 1262.
MOMS 047768
Dept. ?i|6 - Process Description AHOCipjl SKCT1 ON_ 1_1
FLOW SHKKTS Thl B section contains the following flow sheets. 1. Complete process flow sheet. 2. Chlorination Reaction Step 3. Aeration and Distillation li. Mending, Filtration and Storage.
I
3.
< MOWS 047769
MONS 0 4 7 7 7 1
MOMS 0 4 7 7 7 2
Dept. 246 - Process Description
11.
AHOCIOR
SUCTION111
PKOCKSS IN DKTA) 1.
A. NOMKNCLATUHK AND HATCH DATA
Aroclor 3s a trade name used to designate chlorlnatjon products or biphenyl, biphenyl high boilerB, or a mixture of the two. The physi
cal properties vary from light free flowing liquids to crystalline and non-crystalline solids, depending upon the degree of chlorina tion and the composition of the raw materials. Chlorinated biphenyl yields a liquid product of Increasing viscosity up to and Including
6356 chlorine. Chlorination above 63# yields a Bolld product at norma 1 tempera ture s.
A numerical system of nomenclature, consisting of four digits, has boon developed for Identifying the various Aroclors. The first digit
denotes the aromatic raw material used In the chlorination step. The figure 1 -- Indicates 100# technical grade biphenyl. The
second digit denotes whether or not the product Is distilled. The figure -1 -- Indicates undl stilled product, and the figure -2 - Indicates a distilled product. The last two digits of the nomen
clature Bystem denote the approximate percentage by weight of chlorine contained In the finished product. For example, Aroclor 1242 1b a distilled chlorinated biphenyl containing *12# chlorine.
Manufacture of all liquid Aroclors Is essentially the same. Hat-h data arc listed below:
TyP0 Aroclor Diphenyl Charge
1242 4000//
1248 4000//
1254 4000//
1?60 AOOOJ/
1262 4 000//
Chlorination Time
6 Hrs.
8 Hrs. 10 Hrs.
Hrs. 14 Hrs.
Specific Gravity of Crude
1.349-58 1.4o8- 18 1.498-508 1.558-69 1 .580-90 at 65C at 630 C at 65C at 90C at 90C
Weight of Crude Hatch
6670//-.
7580//
8450//
9600//
10,600//
Weight of Distilled
Hatch
6400//
7200//
804 0//
9100//
9850//
Tons of 100# by-product
1IC1 per Hatch
1.24
1.43
2.27
2.47
2.70
Thcoretl ca] Molecular
Weight
257.7
292:6
326.6
369.5
395.6
MONS 047773
K Jk'pt. ?HG - process Doscript!on
b.
AKOCJOK
SECTION 333
HtOCKSS IN DKTA1 1.
it. cuwia nation rjsacm on stop
Chlorination of biphenyl is the only process step where a chemical reaction takes place. All other Aroclor process operations are mechanical. The starting raw materials for Aroclor production are biphenyl and chlorine gas.
Hi phenyl is received in 8,OOQ 10,000, and 20,000 gallon tank cars from Anniston, Alabama. The biphenyl in the tank cars 1b a solid mass because the crystallising point of biphenyl is 68.7C. Steam
must be applied to the tank car coils to melt the biphenyl. It is necessary to melt a vent hole through the solid mass of biphenyl by insertion of a hairpin steam coil through the tank car dome before
applying steam to the tank car coils. The vent hole avoids a press ure build-up in the bottom of the tank oar and possible damage to the car. When the biphenyl is completely melted, it is sampled for ( identification and unloaded through the tank car standpipe by air
pressure to the 2b,000 gallon storage tank. Dry air is used to unload the biphenyl cars to keep the biphenyl free from moisture. The flash point of biphenyl Is 112c.
Chlorine gas is received in a 1) inch pipeline from the chlorine department. In order to facilitate operation of the chlorine
liquefaction system, "snift" gas with a purity of 75-93^ (the remain der being air) is transferred from the chlorine department. The normal pressure of the chlorine gas in Department 2k6 is 20-23 psig.
Hi phenyl (AOOO))1) is charged into each chlorlnator from the measuring tank. The biphenyl charge in the measuring tank can be regulated by valves at different overflow levels. The four overflow levels on the measuring tank permit biphenyl charges of 1800, 2800, 3600, and 1)000 pounds. TWO pounds of anhydrous ferric chloride are charged to the chlorlnators after the biphenyl is charged.
MONS 0<*77?4
Chlorination is carried out in five chlorlnators. Each chlorlnator
is three feet in diameter by sixteen feet high, and constructed of steel. Pour of the chlorlnators has a catalyst bed which is 2'3" in diameter by 8 feet high. The catalyst bed consists of 1-1/2 inch diameter by 2 inches long pieces of pipe which are similar in nature to raschig rings. The fifth chlorlnator is identical to the other chlorlnators except that it has no catalyst basket. The catalyst beds in four of the chlorlnators will be removed as they fail mechanically.
After charging the chlorlnator, circulation of the charge is started before the chlorine feed is begun to maintain an even distribution
of the ferric chloride catalyst. The temperature of the biphenyl is 1]0C-120C at the Btart of the chlorination. The chlorlnator mass
reaches 120C-130C within 30 minutes after the biphenyl is charged.
Dept. ?'l6 - JTocess Description AUOCIOU
c.
SKCT1ON 1J 1
HtOCKSS JN DKTA3L. (Cont'd.)
D. Chlorine gas from the chlorine department passes through a brink
mlBt eliminator and evaporator before entering the ehlorlnator.
The mist eliminator removes most of the Impurities, and the evapora
tor Insures that all of the chlorine Is gaseous.
'
The purified chlorine gas Is admitted to the bottom of the chlorlnator through a distributor plate (Bparger) and passes through the catalyst bed. A ehlorlnator temperature less than Y/0C Is main tained during the chlorination reaction to avoid sublimation arid subsequent condensation of biphenyl In the off-gas system. Knch ehlorlnator Is equipped with a Brink mist eliminator. The purpose of the off-gas mist eliminators Is to trap entrained particles of Aroclor and biphenyl.
The chlorination temperature In the ohlorlnators 1b controlled by automatic control of the air flow through the externa] alr-coolcd heat exchanger. The chlorination temperature must be at least 1?0C 30 minutes after the Btart of the batch and no more than 170 C
to finish off a batch. The normal batch temperature Is 130C. The louvers of the air-cooled heat exchanger located In the externa] circulating line of the ehlorlnator are controlled such that the batch temperature will remain between 120C and 170C. The
temperature of the batch Is recorded at four different points: (1) In the center of the ehlorlnator, (2) Just above the chlorine sparger In the ehlorlnator, (3) at the discharge of the ehlorlnator pump, and {) at the discharge of the air-cooled heat exchanger, point 1 1b alarmed for high temperatures, and point l| as alarmed fol low temperatures. As a safety device, a high temperature sensing element Is positioned at point 2 to shut off the chlorine gas flow If the reaction temperature exceeds 190C.
The batches are continuously circulated at ari average flow rate of 200-220 0PM from the bottom of the ehlorlnator, up through the air cooled heat exchanger, and back Into the top of the ehlorlnator over the catalyBt bed. Chlorine feed up to a maximum of 1500 pounds per hour Is fed Into each ehlorlnator through a flow recorder-integrator which is alarmed.
Progress of the chlorination reaction Is cheeked periodically as needed after 80j chlorination as measured by the recorder-inte
grator.
The degree of chlorination 1b measured by determining the specific
gravity of a sample taken from the circulating line. More frequent gravity cheeks are made when approaching the end of chlorination.
MONS 047775
Dept. 2Jl6 - Process Description
'
AHOCJOR
SKC'J'3 ON 322 22<_ockr.r_ 3 n_ dktaii .
C AKHAT3 CM) AN1) D3ST3 1JAT3 0N
When chlorination is complete, the crude Aroclor is pumped into number two blow tank (capacity 2000 gallons). The crude Aroclor is aerated in the $2 blow tank for two hours or more with dry air. Aeration of crude Aroclor removes most of the free hydrogen chloride.
Crude aerated Aroclor is transferred from the #2 blow tank to the //I blow tank. The #1 blow tank is used as a crude Aroclor feed tank to the stills. Crude aerated Aroolor is transferred from the //I blow tank to vacuum stillB through an automatic control valve which maintains a constant level in the stills. Under normal conditions the automatic feed to the stills is shut off after distilling bout 75,000 pounds of Aroclor. (This is equivalent to filling 7 still receivers). The Btill is then boiled down until a temperature difference between the still coil outlet and vapor temperature , approaches 40C. At this point distillation is discontinued and ' all but a small heel of the residue is drawn off to drums and discarded or Bold as Montar. The still is immediately recharged with crude Aroclor and 200 poundB of lime is added directly to the still pot. Hydrated lime is received in 50 pound bags. The lime neutraliz es any residual HC1 in the still liquor and prevents sublimation of ferric ohloride during the distillation period. Distillation of Aroclops is done under vacuum automatically controlled. The best performance is obtained at a steady vacuum which can be pre-set. by a controller between 30-50 mm Hg. Abs.
Natural gas is used to heat the coil of the Aroclor still furnaces. The pressure of the gas.burner (eclipse, st. 108.5, 2", //5G8, GOO,000 BTU/hr.) is adjusted as needed for production requirements.
The norma] gas pressure Js 3-5 psig.
p. Hl.KNl)lNa, P'31.THAT] CM, AND STORAQK
'
When the still receiver is filled, the distilled Aroclor is pumped
to the blend tank (2000 gallon capacity). After two fillings of the receiver tank have been pumped to the blend tank, approximately
0 pounds of attapulgus earth 3b added to the distilled 121)2 Aro:lor.
All other Aroclors are earth-treated with 20 pounds or Attapulgus
earth. Regular AttapulguB earth is received in 50 pound bags. The
mixture is agitated and filtered to the finished product tank (2000
gallon capacity) through a 3G inch stainless steel Sparkler kilter.
( The attapulgus earth 1b roasted at 250C for a minimum of four
hours in a Orieve-Hcndry drying oven before addition to the Mend
tank. The purpose of earth heat treatment is to remove any moisture
in the earth and activate it. The attapulgus earth absorbs water
and ionic impurities. This improves the electrioal-auali ty
properties of the Aroclor. .
HONS 047776
Itopt_. 2H6 - process Description
AROC10R
SKCT] ONJin.
rnocKSS in pktah.
D. B1-KN1): NQj FI1,THAT] ON AND STORAGE (Cont' d.)
The filter press 1b cleaned after about 5-7 batches or as needed. During the filtration, 2-l6 oz. samples are taken to the laboratory for control analyses. If the control analyses pass specifIcatlons, the batch Is transferred from the product tank to a storage tank. After several batches have accumulated In the storage tank, the con tents of the tank are mixed, and composite samples are taken for lot analyses.
Three underground (15,000 gallon) tanks and five above-surface (each 20,000 gallons) are available for storage of the finished products.
The blend tanks, finished product tanks, and Aroclor 12*12 and 1 storage tankB are blanketed with nitrogen. The pressure of the nitrogen gas Is 10 pslg. Nitrogen blanketing maintains the electrical properties of the Aroclors.
The Aroclors from the storage tanks are drummed, pumped to tank cars, pumped to tank trucks, or transferred to Department A-246 or H-2*l6 mixing tanks for the production of Pyranols, Inerteeris, or pydraul A-200.
Hatches of Aroclor 125*l-mix arc mixed In the //I blend tank. This operation consists of a mix of 10# xylene and 90# Aroclor 125*1. Xylene is received In 55 gallon drums. The flash point of xylene is 85F. Mixing, sampling and drumming of 125*)-mix 1b accomplished directly from the blend tankB. After the blending operation, the blend tank must be cleaned. The bottom outlet of the tank is opened and the tank is cleaned out with live steam and then blown with air.
F HY-PRODUCT HYDROGEN CHIPRIDE
The by-product hydrogen chloride from the chlorirmbors is collected in a common pipeline header and flows to the centra] HC1 absorption unit to manufacture Muriatic Acid in Department F-218. If Department F-218 is unable to handle the off-gaB, it may be sewered at Depart ment 2*iG by passing through a Haveg S-K drowning Jet. The removal of HC1 from the off-gas concentrates the original quantity of hydrogen and air to a point well within the explosive limit. Therefore, It Is essential to either dilute this gas going up the vent stack or increase its velocity past the flame propogatlon rate (15 ft/sec). Thib is accomplished by introducing a sufficient quantity of Btcam into the vent stack.
To remove vaporized and entrained impurities in the HC1 from the chlorinators, the gas passes through a condenser and mist eliminator. The entrained liquid, which 1b primarily biphenyl, is sewered.
MONS 047777
9.
Dept. 22)6 - Process Description
AHOCJOi
SECTIONJV
COMMENTS ON PROCESS
CHI ORINAT]ON STEP
A . RAW MATERIAL Y] K] .T)S
Biphenyl and chlorine are reacted to form a chlorinated biphenyl
called Aroclor. The yields on biphenyl and chlorine vary with the type of Aroclors produced. Each particular type of Aroclor has Its own standard yield factors. Yields are not reported for the Indivi dual type on Aroclor each month. An average yield Is reported monthly and compared with standard and theoretical yields which are calculated according to the quantities of the various Aroclors
produced during the month.
Standard and theoretical conversion factors used in computing chlorine and biphenyl yields are listed below.
STANDARD CONVERSION FACTORS
AROCIOR
___ __
1?A2 1248 129l| 1260 1262 123? 1P9H Xylene
CHIORINE jl/11 Product
.9032 1.0323 1.6130 1.2903 ].^3^ 0.680? 1.0l)5?
BIPHENYL /// Product
0.6l80 0.5380 0.21978 0.1)368 0.1)163 0.7216 0.4480
THEORETICAL CONVERSION FACTORS
AROCIOK
CHIORINE H/jj Product
1332-1P32 1 ]h?-1?A2
]]2)8-lPl)8
HJll-lPJl) 1160-1260
116?-1262
121)2)-10 Xylene
0.61)00
0.82) 00 0.9600 1.0800 1.2000 1.2A00 0.9720
DIPHENYL Product
0.6891 0.6919 0.9367 0.l)79Jl 0.1)11)7 0.3976 0.1)279
HONS 047778
Dept. Ph6 - Process Description
JO.
AKOCIOR
SECTION IV
COMMENTS ON PROCESS
CliJ OK] NAT] ON STOP
B. CAPACITY
The monthly production capacity of Department 2H6 la P,^00,000 pounds of Aroclors on a 7 day per week basis. The capacity of the chlorinators is a function of the following variables.
1. Hatch Cooling Rate - Chlorination of biphenyl is an exothermic ?caction"wH3ch produces 510 BTU's per pound of chlorine gas undergoing a reaction with biphenyl. Biphenyl can be chlorinated as fast as the exothermic heat can be removed from the batch and
maintain a batch temperature of 150C.
?. Chlorine Plow Rate - The rcaotion time decreases as the chlorine
Tlow raTe" Increases. The chlorine flow rate is approximately 1000 pounds per hour per chlorlnator. A maximum chlorine flow
I rate of 1500 pounds per hour per chlorlnator can be attained if desired. The concentration of chlorine in the "Bnift" gas is another factor controlling the rate of chlorination.
3. Catalyst - The chlorination rate increases when ferric chloride catalyst is added to the charge. The best results are obtained when the biphenyl charge contains .05# ferric chloride catalyst.
C. y.AI'LT/
Some of the factors which affect Aroclor quality are as follows:
1. Temperature - According to research experimental results, the cHiorlnatSr temperature must be greater than ]?0C at the beginning of the chlorination reaction to produce stable Aroclors.
?. Catalyst - Good contact is necessary to produce stable Aroclors. Tt~ls 'suspected that agitation and circulation of the reactants improve the effectiveness of the catalyst. The catalyst is also responsible for the chlorine positioning on the biphenyl molecule Pcrric chloride catalyst may be responsible for producing the desired end product. Results of research work concerning catalyst and isomeric distribution are given in Appendix N.
<
MONS 047779
Dept. P*l6 - Process Dcscriptlon
n.
AKOCipK (. SECTI ON IV
COMMENTS ON PROCESS
CHI OR] NAT] ON_Si;KP
C. QUALITY (Coni' d.)
3. Raw Materia] Purity - The purity of raw materials can affect the quality of Aroclors both directly and Indirectly. In a direct manner, impurities which are ionic lessen the resistivity of AroclorB. Distillation of crude Aroclor separates most of the
ionic impurities; however, minute impurities can be carried over to the receiver tanks. Attapulgus earth can remove the remain ing impurities in moBt instances. If any ionic impurities remain after the earth treatment, the resistivity of the AroclorB will be low because such impurities will conduct electricity even in minute concentrations.
In an indirect sense, impurities such as sulfates in the chlorine gas, will poison the ferric chloride catalyst and thus unstable
Aroclors will be produced. The chemistry and mechanism of the catalyst poisoning are not known for certain.
i|. Catalyst Basket - During the latter part of I9C9, the catalyst ( fSaslc&t was removed from one of the five chlorinators. The
material produced in the chlorinator without the catalyst bas ket analysed as normal material. This material was used by a customer wi th satisfactory results.
The catalyst baskets may be removed from the other four chlorinators as they fail. The only restriction on materia] made without the catalyst basket is that it will not be sold to General Electric, or Westinghouse.
AERATION AND DISTILLATION
MUNS 04778G
Steam is not applied to the coils of the blow tanks when aerating Aroclors 1 ill2 and 11*18. This prevents the loss of Aroclor vapors. Eighty psig steam may be applied to the coils when aerating other Aroclors. High moisture may be removed effectively by blowing the crude Aroclor with dry air.
Vacuum trouble on the stills Is usually caused by flashing of product, air leaks, plugged vacuum lincB, or Improper functioning of the vacuum Jets.
Plashing can usually be stopped by operating the still at a slower rate or increasing the flow of cooling water to the vapor condenser.
. Vacuum trouble can be traced systematically from the jets and usually ' isolated.
High color and entrainment will result from overheating (around ?^C above normal distillation temperature) Aroclor, faulty operation of the distillation step, or boiling down thestill too far. (Tars will carry over). The "tail-end still fraction (tars) is a
AROCLOR SECTION IV
COMMENTS ON PROCESS BIENDING AND FI I.THAT] ON Attapulgus Earth la added in the blend tanks to reduce moisture and inorganic chlorides as well as improve electrical properties. If batches do not meet specification (See Appendix B), redlstillatlon may be necessary. The Attapulgus Earth is roasted for *1 hours at 250C before addition to the blend tanks when earth treating Aroclor 12^2.
MQNS 0477S1
Dept._ ?46 - Process Description
AROCIDR
All 'KNI)]_X_A_
EQUIPMENT 1,1 ST
This section contains an equipment list with each piece of equip ment listed by Item numbers In a consecutive numerical sequence. Miscellaneous items of Dept. 246 such as Instruments have not been assigned Item numbers. Equipment without Item numbers is not included in this equipment list. All equipment of Dept. 246 will have Item numbers assigned sometime in the future. This equipment list should be expanded as additional Item numbers are assigned.
Item Equipment No. Name
Equipment Number
Description
101. Hi phenyl Transfer 19-0582 Taber vertical submerged cent,
Pump
66-3930 pump, size C-3, 2?" inlet,
2" outlet. Connection bronze
except shaft which is monel.
Motor is 3 HP, 1800 RPM.
10? Diphenyl Storage Tank
21-2210
Tank purchased from Rogers and Wrigler. Capacity is 25,000 gallons. 10' 6" Dia. x '10'6"
long. 3/8" plate shell. Design pressure is 50 psi .
103 Diphenyl Head Tank
21-0767 16-7225
Tank made by Graver. Dwg. C-799. Steel tank 4'6" ID x 5'6" Btr. side, dished heads, shell 3/8", top head 3/8". and bottom head 3/4" with 1/2"
Jacket over it and ending 9" up on tank side. Welded throughout. Test of tank is 60// and Jacket is
105// hydro, pressure. Mixer is Mixco Model N33075, gear driven propeller. Motor is 440/3/60
TKKC, 1725 RPM.
lO'l Biphenyl Peed
66-7224
Durco Horiz. Cent. pump. 2" inlet, 2" outlet. Cap. 100 CPM Motor is 7i HP, 1760 RPM
105 Chloririator 7/1
21-3261
Tank made by Nootcr. Dwg. K-800. 3' ID x 16' long with pig. head. Shell 3/8" and head 7/16" thick, 3/16" Jacket over lower half of
tank.
106 Chlorlnator #2
21-3245 Same as Item No. 105.
RUNS 047782
Dept. P46 - Process Dcscript]on
AR0C1.0R
APPENDIX A
EQU1 PMKNT IJST (Cont'd.)
Item Equipment No. Name___
Equipment Number
Deseriptlon
107 Chlorlnator #3
21-3251
Tank made by Leader Iron Works. Otherwise, same as Item No. 105.
108 Chlorinator #4
21-1283 Same as Item No. 107.
109 Chlorlnator #5
21-1432 Same as Item No. 107
110 //] Mi Bt Eliminator 15-0581 Tank made of carbon steel. Element made of carbon steel. Design pressure
is 50 psig. and design temperature is 300E.
111 //2 Mist Eliminator 15-0582 Same as Item No. 110.
11? H3 Mist Eliminator 15-0583 Same as Item No. 110.
113 flh Mist Eliminator 15-0584 Same as Item No. 110.
114 //5 Mist Eliminator 15-0586 Same as Item No. 110.
115 Chlorine Mist Ellm. 21-4042 Tank made by Alpha. Carbon steel construction. Coded tank. Element 316 stainless steel. 15" dla., glass fiber inverted type. Design pressure is 50 psig and design temperature is 300P.
]]6 Chlorine vaporizer 38-51187 Chlorine vapor!zer made by Armstrong Company. 8-5/8" OD x 11' long. Carbon Btecl construction. Chlorine
side steel designed for 250 psig. at
400E. Steam side designed for IOC psig at 4oOE.
120 1?1
Knockou t
Chlorlnator //] Pump
19-4305 66-8109
Steel vertical 60 gal. tank.
Durco Mark II horiz. cent. pump. Inlet is 3" and outlet 1b 2", ductile, iron, with Duramctallic seal and Marizel lubricator. Rate is POO Ql'M at 25' static head Sp. Gr. of 1.5. Motor is 10 HP, 1800 RPM.
MONS 047783
Dept. ?1|6_- PrOC_eBB_ Description
15.
AKOCLOK APPEND] X A
EQU1 PMKNT LIST (Cont'd.)
3 tem No._
Kqulpmcnt _ Namc_
Equipment Number
Dcecrl ptl on
3?? Chlorinator H2 Pump
19-)I306 66-8110
Same as Item No. 121
1?3 Chlorinator #3 Pump
12t| Chlorinator #)| Pump
1?5 Chlorinator #5 Pump
IPG Plow Tank //?
19-^307 66-8111
19-'I308 66-8112
69-3892 66-6509
21-2086
Same as Item No. 121
Same as Item No. 121
Same as Item No. 3.21.
Tank made by Graver. Iwg. K-863. 7' x 7' str. sides, dished heads 1/?', shell 3/8", 5 turn coil of 2" pipe supported on brackets welded.
1P7 Wow Tank #2 Pump
66-2956 69-0577
Taber horl 7.. cent. pump. Type 1.-2. 2\ " x 2". Semi-steel with monel shaft and water jacketed stuffing box. At 20' Btatic head, rate is 80 GPM, 1.5 Sp. Or. at 500F. Motor is 3 HP, 1800 RPM.
1?8 l
Air Dr^er
lJj-010l) 1
Anders Iykens Corp. Air dehydrator. Two code welded tankB filled with 55 lbs. activated alumina. I>wg. #6)156.
l?9 ' '.^oV/ Tank f/i Pump
19-0629 66-9080
Same as 1tem No. 127.
13 ' , still Hi
20-001)3
Vacuum Btlll purchased from Graver.
Dwg. C-809. Size 6' Dia. x 5'6" Ig.
on str. side,
shell, dished head
5/8". 60# hydro. pressure test.
131;, Kurnaoe //I
13? Still //3 Pump
(
27-001)5 19-059))
Steel heater furnace. Steel shell 3/16" x 3'9" dia. x 1)' 10j" Ig. lined with insulating fire brick. One col 3 2" xHy pipe, 3? turns formed Into a ?' dia. coi3 with spare blocks and legs. Dwg. E-806.
Taber vert, sub, cent. pump, type J.-2. CaBlng, yoke, and Impeller made of steel. 2" Inlet and 2U outlet. Length 7 '9". Capacity is 76 GPM, static head 15', Sp. Gr. 1.8 at 700E. Motor is 5 HP, 1750 RPM
MQNS 0*7784
Dept. ?kbProcess Description
1 6.
AKOCIOU
APPKND1X A
BftUlPMKNT LTST (Cont'd.)
3 tcm No
EquJ pmcnt __ Name
Equipment Number
Dcscript!on
333 sun 7/2
20-0062
Vacuum Bill] purchased from Nooter. IWg. 69,l`l. 61 11) x n'lO" sir. shell Internal, pipes, standard dished heads. Glass wool Insulation 3" with l/2" finished coat.
13'l Furnace //2
20-0066
Same as Item No. 133.
135 SU11 //2 Pump
66-1759 69-1277
Taber vertical sub. cent. pump. Type Cl.--1|, x 2", else 38JI. Pump Is dynamo steel. Capacity Is 75 GPM at 25' static head, Sp. Gr. 1.8, Motor Is 7i HP, 1750 RPM.
136 Condenser |/1
38-0770
Heat exchanger made by Nooter. Dwg,
B-651. 12" dla. 5' long having nineteen 2" 01) 11 ga. monel tubes, monel tube sheets, monel reducer, and carbon steel Jacket and back up rings on flanges.
137 Condenser #2
38-1370
Same as Item No. 136.
130 Recei ver Tank //I 21-0771 Vacuum receiver tank made by Nooter. Dwg. C-795. SI ze Is 5'6" dla. x 5'6" str. side, 3/8" shell, 1/2" bottom and removable head. 2" IP,
size xHy monel coll with 2" Inlet and 1" outlet. 3 turns, 5' dla. along side and 3 turns spiral on bottom. 60// hydro, pressure test on tank and 300// on coll.
139 Receiver Tank //2 21-1377
Tank made by Nooter. ix#p, C-Y9
Same as 3 tern No. 338.
,
1^0 Receiver Pump 3 66-9067 Rlackmer pump, lypc PA-501,, bronze
69-0565
rotary pump, monel shaft, C.l.
base. Capacity 1 s 50 GPM, 1.65
Sp. Gr., 350 to 500F. Motor Is
2 HP, 1750 RPM.
i'll Receiver lump #2 66-5670 Same as Item No. ]<10. 69-1258
MllNS 047785
ltej.it. 2D 6 - Process Description
37.
AKOCLOH
AP1'KN1>3X A
EQUIPMENT LIST (Cont'd.)
J tom Np_j_
KquJ Client __ Name
EquJ pment Number
Description
].J|2 Hlend Tank #1
21-0779
Tank made by Graver. Dwg. K-86?. Welded steel tank, 7' dla. x 7' high dished heads l", shell 3/8"- All surfaces Bpraycd with .005)" zinc then .003" tin. 2" xlly pipe col 1
and supports. Case bronze stirrer and bronze shaft. Test of tank is
60# and coll Is 300# hydro, pressure.
]l)3 Hlend Tank #2
mu Hlend Tank lamp
21-1399 66-0217
19-1757 66-3718
Same as Item Ho. Ill2.
Taber Horlz. Centrifugal pump. 30l|
s.s. 2" x l|" capacity 6o GPM, 100'
head. Motor Is 10.0 lip, 1800 RPM.
3113 36" Sparkler Fi 1 ter
15-0238
Filter made by Sparkler Mlg. Co., 33-P-12 horizontal plate filter.
Typo 30;l s.s. Jacket tested for pressure of 30 psi .
I'l6 Finished
21-0780
Filtrate receiver tank. Dwg. K-862.
Product Tank #1
Same as Item No. ill2.
1/I7 Finished Product 21-111 00 Tank made by Nooter. Otherwise,
Tank #2
same as Item No. Ill2.
3H8
Storage Tank #3
21-0768
Tank made by Graver. Dwg. C-609.
Horizontal steel, 10' dla. x 26' long
on str. Bide, dished heads, shell
4", head I/16". Test of tank is 60#
and coil is 300// hydro, pressure.
All coils, supports, inside surfare
sprayed with .003" zinc and .053"
tin.
lll9 Storage Transfer 19-0585 Taber Vert. Sub. Pump. IVig. A-387.
lamp #3
66-0853
Type C-3, 2" x 2", C.l . body,
length 1.1'6". Cap. 30 GPM, 60' static
head, Sp. Gr. 1.18 at 370&F. Motor
is 3 HP, 1800 RPM.
fi150
Storaf Tank #<l
21-0769
Same as Item No. 3l|8
Tank {
fi133 Storaf Transfer 19-05814 Taber Vert. Sub. Pump Type 1.-2.
lamp t
66-1501
2g " x 2". length 11'6". Cap 30
GPM at i)01 static head. Motor is
3 HP, 1800 RPM.
MUMS 047786
Dept. 246 - Process Description
38.
AKOCIOR API'KNJ>] X_A
WJ2?1iiNT U ST (Cont1 d . )
2 icm No.
Equipment Name
Equipment Number
Descrl ptl on
15? Storage Tank //5
21-1310
Tank made by leader Iron Works.
C-609. 10'Oft x ?6' long on sir. shell. Same as Item No. 148 for other characteristics.
153 Storage Transfer 19-0929 Same as Item Ho. 151, except
ltunp Tib
66-085O
length is 4 '7".
Vjk
Storage Tank i/8
21-3526
Slpha tank 1P'6" dla. x 2?' high.
20,000 glllon storage capacity.
Aluminum constructed Dwg. TS-D-30]].
155 Storage Transfer 19-3172 Durco pump, model WH2 A13oy constr.
Pump 7/8
66-2631
2" x l|", 8" impeller. Cap. 160 GPM
at 55' head. Motor is 7i HP, 3740
RPM.
Vj6
Storage Tank in
21-21)04
Alpha tank. 13' OD x 20' high.
Vertical tank, constructed of 3/8"
mild steel. Capacity is 20,000 gals.
157 Storage Transfer 19-2077 Pump made by Blaokrner. Monel shaft,
Pump 7n
66-1691
2-J" x Pi". Cap. 90 GPM. Vj1 head.
Motor is 3 HP, 1750 RPM.
158 Scales 167 Wow Tank #1
24-0246 2/1 -0187
21-0750
Made by Toledo Scale Co. 800// capacity, dial type scale.
Tank made by Graver. Dwg. K-863. 7' dla. x 7' str. side, dished heads shell 3/8". 5 turn coll of ?" xHy pipe.
]69 Surge Tank
22-0751
Cyclone collector made by Graver. Dwg. B-695. 48" dla. x 2y" on str.
side, 3' 6" long and tangential inlet near top of side. 3/16" steel throughout of welded construction.
170 Cl ty Water Pump H1
69-1083 69-3365
Taber Horiz. pump. Model CH5, 3" x Pi" 9" impeller. Cap. 180 GPM, 50' head. Motor is 7i HP, 1800 RPM.
171 Cl ty Water Pump i/P
17? Off-Gas Mist Eliminator
69-2078 66-1796
21-5150
Same as Item No. 170
30"0D x 13'-3" straight side, steel construction, vertical for Brink Filter Element //15-0630(//?496 carbon
173 Off-Gas Heat 38-5588 8'long x 16" 01), 2 pass on tube
Exchanger
Bide, Z> bafflco, cteel construction.
MQNS 047787
Dept. 246 - Process Description
( AKOCIOH APPENDIX A
EQUIPMENT LIST (Cont'd.
19-
3 torn No
Kqui pincnt Name
EquJ pment Number
Description
100 Exhaust Blower 11-0265 Made by American Blower Co. ,ypc 450E. Capacity Is 6408 SCPM at 1310
RPM. Dwg. K-10699. Motor js 19 IIP.
189 Coke Scrubber #1 21-0756 Scrubber liquor tank made by Graver. Dwg. C-800. 4'6" Dla. x 5'6" on Str.
Side. Coll 3 turns of 1-?" x Hy pipe.
186 Coke Scrubber 7/2 21-1396 Same bb Item No. 185.
200
Cyclone Separator 21-1413
Separator made by Helntz Stec. 3' ID x o' high tangential separator with
Integral vapor pipe complete.
203
Air-cooled Heat
38-5328
Air cooled heat exchanger made by
Exchanger //5
Dialer. Cooling capacity is 1,200,000
BTU/hr. Steel construction except for
aluminum fins, van motor is 2 IIP,
1150 RPM.
203 Steam Vacuum Jet #1 35-3523 #2 { Worthington 3-stage vacuum Jet.
204 Steam Eacuum Jet =H2 35-1686 Same as Item No. 203.
205 Steam Vacuum Jet #3 35-3533 3-Btaee porcelain Kubatl vacuum ejector with 10" 11) porcelain conden
ser. Jet haB a capacity of 10///hr.
air at standard conditions. Jet designed for ISO// steam and 2 mm Hg
absolute.
206
Off-gas Drowning Jet 35-47!
Made by Schuttc-Kocrtig. 8" Haveg
fume scrubber. Complete with stand
ard nozzle.
207 Drying Oven
14-0138
Grieve Hendry drying oven, 440 V.,
3 phase, 60 cycle, manual reset temp, controller range 0-400C.
210
Air-cooled Heat
38-5564
Same as 1tem No. 201.
Exchanger //I
66-8113
213
(
212
Air-cooled heat Exchanger //2
Air-cooled Heat Exchanger //3
38-5565 66-8114
38-5566 66-8115
Same as Item No. 201. Same as Item No. 201.
213
Air-cooled Heat
38-5567
Same as Item No. 201. MONS 047788
Exchanger //4
66-8116
20.
Itopt. 246 - Process Description
AKOCnOK
APPKND3X A
EgUlPMKNT LIST (Cont'd.)
] tem No._
Equipment Name
Equipment Number
Dcscrlptlon
214 Air Dryer
14-0138
215 City Water
69-4363
Worthington 3CNFK84 with 8" impeller
Circulating Pump 66-8179
and Monsanto standard base.
?]C TollBh Filter //9 Storage
15-0633
Alsop filter model No. PAK 125-4, 316 s.s, 6,000 in.^ filtration area, 840 in.3 volume.
237 Polish Filter #10 Storage.
15-0634
Same as Item No. 2l6.
218
Polish Filter flll Storage
15-0635
Same as Item No. 216.
None
Chlorine Pressure 29-1547 Recorder
Made by Taylor Instrument Co. Pressure Recorder with 2 pens.
Range 0-100.
None
Chlorlnator Flow Recorder
29-2019
Made by Taylor Instrument Co. Flow Recorder - Controller Cat. No.
137RF135. 12" chart, 0-10 Sq. root chart.
None
Water Meter
29-2486
Made by Worthington Corporation. 3" model JH turbine type water meter.
None
#] Still Tempera 29-3885 ture Reoorder
Made by Leeds & Northrup Co. Temperature Recorder. Range 0-^l00C.
None
fil Still Absolute 29-1170 Pressure Controller
Made by Taylor Instrument Co. Absolute pressure Recorder - Controller.
None None
200// Steam Flow Reoorder
29-0835
fi2 Still Absolute 29-3353 Pressure Controller
Made by Bailey Meter Company Flow Recorder.
Made by Taylor Instrument Company. Absolute pressure Recorder Controller.
None
//2 Still Tempera 29-0844 ture Recorder
Made by Leeds 8c Northrup Co. 6 point Temperature Recorder.
None
#2 Still level Controller
29-1463
.Made by Taylor Instrument Co. Liquid level Recorder - Controller.
MOMS 047789
y Dept.. SM6 - Process Description
2]
AUOCIOK APPEND!X_A
EQUIPMENT LIST (Cont'd.)
] tern No.
Equl pment Name____
Equl praent Number
Desert ptlon
None
Chlorlnator
29-0280
Temperature Hecorder
Made by Leeds & Northrup Co. 12 point Temperature Recorder.
None
#1 Blow Tank
29-2916
Temperature Recorder
None
80# Steam Plow Recorder
29-5^52
Made by Taylor Instrument Co. Temperature Recorder Controller Adjusts 200# steam to #1 Blow Tank Cat. #86 RM43186-12.
Made by Poxboro Company. Type T37, recording flow meter with Integrator and Indicator. Meter body 316 s.s. Integrator for 80#, 1\00F. Bteam.
None
200# Steam
'y Plow Recorder
29-5^53
Made by Poxboro Company. Type T37 Reoordlng Flow meter with Integrator and Indicator. Meter body 316 e.s. Integrator
for 200#, 510P. steam.
y
MONS 047790
Dept. ?56 - Process Description
22.
AHOCIOH
APPEND] X_H
SPEC]F] CAT]ONS
The following Is a list of the raw materials used for the manufacture of Aroclors. Specification sheets are Included where they exist.
Material Code
Raw Material
8?601
HI phenyl
33500
Ferric Chloride
38800
1.1 me
19509 81059
Attapulgus Earth Chlorine
53099 65005
N1trogen Xylene
The following Is a list of the finished products manufactured In
department 256, Specification sheets are Included where they exist.
Product Code 811.12----------------
821.15 8ll0l(Elect & Non-Elect) 81102 (Elect 8e Non-Eleot) 8ll03(Elect 4: Non-Elect) 81105(Elect 8c Non-Elect) 81107 8)101-81102 (Mix) 82868
Product
enc
Aroclor 1252 Aroclor 1258 Aroclor 1255 Aroclor 1260 Aroclor 126? 1252 - 1258 Mix
Montars 1, 2, 3 and 5
MOWS 047791
MONSANTO CHEMICAL COMPANY OMOAMC CMIMIC4LI DIVISION
v-amwmwm
SPECIFICATION MATERIAL DIPHENYL (BIPHENYL)
CHCMICAL FORMULA
MtTIKMl COOK
82601
UIINO DIPT!.
246
ANNISTON PLANT
MOLT. 15*1 -20 ^U^fN|JIDEB BPBCB
0^0
AMPLE POP ANALVBIB
2 x 16 oz. w.M.Bottles
UNRESTRICTED INFORMATION
Routine Tests
Appearance and Color
Crystallizing Point OENERAL INFORMATION Distillation Range:
First Drop to Dry Point
Specification Light Yellow cryst. Solid 68.7*C, min.
2.5*C, max. Must lnolude 255*C within Range
Issued^; R m in
Method Number 10,252 10,298 10,299
This specification Is the property of Monsanto Chemical Company and la for Internal use only.
pH IN M INC Vo U/M>
MONS 041792
Monsanto
enoANie chcmIcal* eiviaiOM W, G. Krummrich Plant
RAW MATERIAL SPECIFICATION
PRODUCTION T. W. Dalton C . A . Pratte
mol wl. 162,21
MATIRUk
33500 P1. ANT
Ferric Chloride Anhydride UttMO DOT*.
WGK
233
"jAirTraK
upplicr
McKesson St Robbins
--------- 1---------
---------------------
APPROVALS
M. A. Terpstra QUALITY CONTROL (CMt Chmi*t) W. J, Gresham
CHCMICAL FORMULA
Fe Cl,
ACTKRIBTIC
UNRESTRICTED INFORMATION
Appearance
Assay Sulfates Ferrous Salt* Solubility:
10:10 of Water
10:10 pf Formula 30 Alcohol
Black powder or Granules 97.0%, min. 0.05%, max. Trace, max.
Complete to slightly turbid, max. Complete to slightly turbid, max.
J.F.Q, 16-A
22-570 120-570 S-570-1 112-B
W Kutln Antlylf, Alt
Artmly* MfiMil Milf<
MQNS 047793
Monsanto
I.ANIC C HA MIC A l_ tllVIK
( RAW MATERIAL. SPECIFICATION
PRODUCTION P. E. Heislei* C. A. Pratte
MATKAiAL CAM
38800
WGK DAT, CFFKCTIVC
7/21/66
APPROVALS
Lime, Hydrated
UAINA DKPTI. 222, 246
UPPLItft
.
Mississippi Lime Co,
M. E. Gibbs OUALIT V CONTROL (Chimt Ctfmtti)
W. J. Gresham
Ca (OH)2
6/20/63 C NAPACT eristic
AMPLC POP ANALTIII 1 x 16 oa. W.M. Bottle
Appearance
Fine white or slightly gray powder, free from lumps or gritty material
Assay (CafOHh)
92.00%, min.
(
Carbonates as (CaCOj)
3,00%, max,
Magnesium
0.50%, max.
Sulfates (as $0*)
0.30%, max.
10, 188
10,191 10,193 10,192 10,189
Supplier's certificate of analysis to be sent on day of shipment to: Chief Chemist, Monsanto Co., Monsanto, 111,
(
(10 HtlEAi, Antfyslt, 4ff ffAif, 4ml,nd A,
Mfy.
MONS 0A7794
Monsanto
MATCAIAL COOK
19409
Atlapulgus Earth 200/UP
PLANT
UIINI DCPT1.
W. C. Krummrich Plant
WGK
246
( RAW MATERIAL SPECIFICATION
1-21-66
UPPLIKA
Mineral fc Chemical Phillips Corp.
PRODUCTION
P. E. Heialer
APPROVALS
W. D, Robinson
C. A. Pratte .
9UALITV CONTROL (CM*I CAMt0
W. J, Gresham
CHEMICAL FORMULA
Clay
11/15/62
CHARACTERISTIC
2 x 16 02. W.M. Bo tile a
LIMIT*
UNR ESTRICT^D INFORMATION ;rj Volatile Matter (at 950*C.) |R) Meah Teat:
Through USS 325
6 - 6% 90%, min.
J. P. Prader
MKT MOD
This material ia not accepted without the supplier's analysis of the above properties.
(
(IV AmJfaJa, 4ff ilMri If nkmiI Mlf.
HONS 047795
Monsanto
MATCHIAL COD*
43099
PLANT
Nitrogen Gas
U*IN DIPY*.
.
RAW MATERIAL
( SPECIFICATION
WOK
DAT! KPPCCTIV*
FEB 1 8 1965
See Below Air Reduction Sales r.n .
APPROVAL!
PRODUCTION
J.M.C.. P.E.^.. W.B.P.. C.H.S.
PtaCAPCH
uFS
R.W.B.. H.W.K.. M.A.T . W.D.R. . J.A.s!
QUALITY CONTROL (Chill CheatIII)
C.H.C,
W.J.G.
C.H.R. J S.M.
>1 PKCWIPTION
CHIMIOI rgWMVLA
Grade - 0. P. Special Nitrogen
Yy
____
cmaract*qi*tic
AMPLK POP ANALVtl*
-----
LIMIT*
IMUIOIV
D- 0**1*
UITM
Assay (1)
Oxygen
Hydrogen
DewPoint
Nitrogen Argon Oxygen Carbon Dioxide Acetylene
99.9%, min.
0.1*, max.
0%
. -76F
Typical Analysis
99.78% 0.12* 0.1*
<.00005* <.00005*
(l) Nltrogeh plus inert rare gases (?) Any analyses to be obtained from supplier on request. (5) B-215, C-216, 244, 246, 247, B-254, A-255, 256, 267, 270.
(
': :
-
(10 RmMm AnafyaU. All tlAsti Analyse* *y repeal mmly.
MONS 047796
Monsanto
OR4ANIC CMIMICAL* DIVISION
MATCMIAL CODS
64005
PLANT
MATCMIAL UAINS 0PT.
5* Xylene
WGK
( RAW MATERIAL
DATS CFPCCTIVC
A-255
SPECIFICATION
6/21/66
Chem Tech
PRODUCTION
J . E. Smith
P ROC UltMlNT
A. H. Smith
APPROVALS
C. Eaker (Nitro)
DUALITY CONTROL /CM*/ Ch*n/*f>
W. J. Gresham
POCMIPTION
CMIMICAL FORMULA
C6H(CH,),
mol, wt. 106.1$ 7/12/63
AMPLC POM ANALYSIS
1 x 16 ot.
C HAM AC T KAlt TIC
UNRESTRICTED INFORMATION
J. P. Prader
(R) Appearance
Clear Colorless liquid
(R) Sp. Gr. @15.5/15.5 *C,
0.860 - 0.870
T-2516
(R)
(
Distillation Range 1st Drop Dry Point
137*C., min. 143*C., max.
T-2516
100% over in
5*C., max.
Acidity Sulfur compounds
No free acid Free of H2S and SOz
Supplier's certificate of analysis to be sent on day of shipment to: Chief Chemist, Monsanto, Company, Monsanto, 111.
(.
(A) Analfl$, Alt (Mm Antlya4 by w|m*I wily.
Mows 097797
Monsanto
FINISHED PRODUCT SPECIFICATION
PRODUCTION
T. W. Dalton W. E. Ault
UPRODUCT
| CHLORINE
Liquid
tOCPT.
| 232
Pl'AnI D WGK
PRODUCT COOK
81059
" u
"
Sales and Internal
ALII CODI
j JUN 2 9 1%6
3060-000-06-03
RCfCiACM
N. F. Mueller
Duality control fCMr camioO
W. J. Gresham
CHCMIC 4k 0MUL*
70.914 6/24/63
AMRlS POA ANALVIIP 1 x 40 ml. Beaker 3/4 full
CMAAACTCAIITte
UNRESTRICTED INFORMATION
(R) Appearance
Clear heavy liquid
(R) Color (R) Moisture
Amber to greenish yellow .015%, max.
(R) NVM
. 01%, max.
J. P. Prader MTNN
10, 748 10,748 12,793 12,793
Iron as: Fe. FeClj, 6H*0
Report % Report %
10,bSS
When ufted in manufacture of AC1 product, the specification on Iron as Fe is 20 ppm max. (H.V.Moss)
For use in Depts. 264, 256, 236, 243, 244 and 251.
(
MONS 047798
4mrtlvifcv rtauett Only
MONSANTO CHEMICAL COMPANY ORSANIC CHIM)CAL| DIVISION
PRODUCT COOS
81115
W. Q. Krummrlch PlanLf Internal
FINISHED PRODUCT
ACM COOK"
SPECIFICATION
IOKPT. OR JO*
___ _246__ J.F.Q..
~PnOOUCT fTVrf Num)
TTP*
. Aroclor 12?2_____________________ (MCS -
'product (OhMilMlffOT*) '
TVPI
5236 Chlorinated Biphenyl
C HIMICAt FORMULA
236)
Issued APR 7' W. CL. Kc
New
ItAMPLt FOR ANALVm
_____________ 2 x 16 oz. w. M. Bottles
Routine Tests Appearance Sp. Or. (825/15.5'C Acid Number Color, APHA H20 General Tests Chlorine
Specification Clear Liquid 1.266 - 1.276 0.014 mg. KOH/grm. max. 100, max. 55 ppm., max.
51.5 - 52.5*
Method No.
10,114 10,087 10,084 10,620
This specification is for Internal use only.
MONS 047799
MONSANTO CHEMICAL COMPANY
OftQAHIC CHCMCAtt OIVUION
Krummrlch and Anniston
FINISHED PRODUCT
' SPECIFICATION
AoouCT'irT>4
__ Aroclor 1242 ____________
VrODUCT
Mmf)
RROOUCT COOK
lOKRT. OR JOB
81101-82612 IW0K-g46-Ann.27
Sales
INLU COOK
1040-240-04/ll/l6-03/09
Issued
W. 0. Xrummrich Whnfc
By. ,>v, -6 ih
CNRMCAL FORMULA
5-4-61
Mixture
KAMRLK ROM ANALVMt -___ 3 X 16 OZ. V. M. BQttlMM___
UNRESTRICTED INFORMATION Routine Tests
Condition
Color, APHA
Sp. Or. (25/15.5*0) Acidity (mg, KOH/g.)
Moisture (H*0) (ppm.)
General Tests Distillation Range
(ASTO D-20 Corrected) 10)6 Distilled by wt. 90)6 " " " Viscosity 8100'P (SUS)
FlaBh Point (*F)
Fire Point
Specification Clear 100 max. 1.381 - 1.392 0.010, max. 50, max.
325*C, min. 360*C, max. 82-92 338 - 392 None
WOK
Anniston Metnod no.
10084
0-1
10084
046
10114
052
10087
050
10620
047
10117
14-31-54
10086 10123 10123
049 14-28-54 14-28-54
HONS 047800
MONSANTO CHEMICAL. COMPANY ftftftAMC CNIMCAkf MVIMM
W.O.K. and Anhlaton FINISHED MtQDUCT
mioovcT cods 81102
UM Sales
IALU COM
|<mre46i90K | 27 Ann.
SPECIFICATION
1040-260-04/11/16-03/09
ftftOOUCT (W9*
TVftB
Aroolor 1248 Electrical Grade (pyranol 1498)
fftOPWCT fOft199l ftlSj
TTftft
Issued 1/10/64 Corrected 2-16-64
Mixture
MOL *T. MPiniMI IPICI Of
2-12-60
lAMPLft fOft AMALT9W 3 x 5 Pt. Amber Bottles
UNRESTRICTED INFORMATION
Routine Tests
Color, APHA Condition Sp. Or. 965/15-5" C , Aoidlty (mg. KOH/gra.) Moisture Refractive Index 925*C Inorganics (Free) Chlorides Pour Point Dielectric constant
(1000 cycles 9100*0) Resistivity
(500 VDC 910p*C 0.1" QAP) as OHM-CM x 309 Hydrolysis Stability Test (as Chlorides) Monsanto Stability Test (as Chlorides) Distillation Rqnge (ASTM D-20, Corrected) 10f Distilled by Wt. 90% Distilled by Wt.
Specification
50, max. Clear 1.405 - 1.415 0.010, max. 35 PPm., max. 1.6285 - 1.6305 0.05 ppm., max. 0*C, max. 4.5 - 4.7
500, min.
1.0 ppm., max.
0.5 ppm., max.
5*I5*C, min. 385*C, max,
Method No's.
WOK
Annlstor
10,084 14-44-54 10,084 0-1 10,114 14-49-54
10,087 14-42-54 10,620 14-53-54 10,125 14-34-54 T-2092 014 10,115 14-27-54 11,608 14-36-54
11,607 14-35-57
Tl2087 010 11,503 14-61-57 , 10,117 14-31-54
general Tests (made only on request)
Sulfates
Dleleotrlo Strength 925*C Fire Point Viscosity 954.4*0 (SUS) Corrosion Test
(6 hrs. 9210*C with bright aluminum foil) Change In wt. of A1 (%)
None 35 KV, min. None to boiling point
73 - 80
0.0
12,169 - - 11,605 043 10,123 14-28-54
10,086 14 -A -52 10,126 14-55-57
(over)
MONS 047001
A. C. Color, APHA A. C. Condition
A. C. Acidity (mg. KOH/g.) A. C. Inorganic {Tree) Chlorides
60, max. Clear
0.010, max.
0.05 ppm., max.
OENERAL INFORMATION
Specific Heat Fixed Chlorine
0.27 <17.5 - "8.5*
10,08" l"-""-5" 10,08" 0-1 10,087 1"-"2-514
10,118 010
MONS 047802
MONSANTO CHEMICAL COMPANY OAOANIC CHEMICAL* DIVISION
Krumnrleh and Anniston
FINISHED PRODUCT
SPECIFICATION
~PRODUCT (TYarie J
Aroolor 1254
'PRODUCT
flam*)
PRODUCT CODE
1 DIPT* OR JDD
81103 - 82613 1WGK-246-Ann.27 Issued 7/15/64
USE w. o. Krummr'lcn riant
Sales SALESCODS
By /YU H
1040-280-04/11/16-05/09 . TYPE
Non-Electrical Grade TYPE
MOL *T. 5-4-61
Mixture
' -`
SAMPLE POM ANALYSIS
-
5 x 16 .pz, W. M. Bottles________________________________
UNRESTRICTED INFORMATION Routine Tests
Color, APHA
Sp. Or. 065/15.5*0
Acidity (mg. KOH/g.)
Moisture (Ht0) (ppm.)
Oeneral Tests
-
Flash Point
Vlsooslty S210*F (SUS)
Specification
100, max. ; 1.495 - 1.505
0.010, max. 50, max.
None 44-48
WQK
Annlstor
Method no.
10084 10114 10087 10620
046 052 050 047
10125 . 10086
14-28-54 049
MGNS 047003
Monsanto
ANNISTON AND KRUMMR1CH Rinishid product SP1CIP1CATION
Hwluifttw 1
P. E. Htlilti
Ui.ll
1
W. . Ault
HMWIT
Pt*"fAroclor 1260
Electrical Grad*
Anniaton 'wmvnn.
Krummrich B110S WGK___
Ann. t WC,K - ?
Salww
5/25/66
1040-290-04/11/16-03-09
IMIIMIU---------------------------------------------- ----------
W . D. Robtnaon w*6iTv *TN*b rciuwcfMMiM/ O. E. Dolin
W. J. Greaham (MlMt *6 PMWW*
WT.
2/7/62
BNBkrDi
3 x 5 pt. Amber Bottle a 6HTt
UNRESTRICTED INFORMATION
(R) Color (APHA)
150, max.
(R) Condition
Clear
<R> Specific Gravity 90. IS. 5*C. 1.555-1.566
(R) Acidity (mg KOH/g,)
0.014, max,
(R) Moiature (HjO) (ppm)
35, max.
(R) Viacoatty 0 210T. (SUS)
72 - 7$
(R) Refractive Index 0 25 *C.
1.6455 - 1.6470
(R) Inorganic (Free) Chloride# <R> Pou^r Point (*C) (R) Diatillation Range
0.05 ppm, max. 25 - 34
(AS'fM D-20, Corrected)
10% Diatilled by wt,
385 - 396'C.
50% Diatilled by wt.
390 404 *C.
90% Diatilled by wt.
400 - 420*C.
(R) Corfoaion Teat (6 hr a. 0 210*C, with
bright aluminum foil)
(R) Change in weight of Al (0) (R) A C. Color (APHA)
(R) A.C, Condition (R) A.C, Acidity (mg. KOH/g.) (R) A.C(. Inorganic (Free)
0.0 150, max. Clear 0. 014, max.
Chlpridea
'
0, 05 ppm, max.
(Over)
J. P. Prader 1 MM
100S4 10084 10114 10001
10620 10006 10125
10118 10115 10117
14-44-54
14-49-54 14-42-54 14-53-54 14- 4-52 14-34-54 14-48-57 14-47-54 14-31-54
10126
10004 10004 10007 10118
14-55-57
14-44-54 14-42-54 14-48-57
HONS 047806
Xemttnt
AH |l/o AnmlyitA & raot Oalv
ONRESTRICTED INFORMATION (Cont'd.)
Charactcri.tic
Limit a_________________________ Method
Fla eh Point
Fire Point
-
Fixpd Chlorine (%)
(R) Dielectric Strength
0 50*C. (R) Reactivity
(500 VDC 100*C.
.1M gap aa ohm-cm x I0y)
.(R) Dielectric Constant
1000 cyclee, 100*C.
None None 59.5 - 60.5
30 K.V,, min. 500, min.
3.6 - 3.0
WGK
10123 10123 10068
11605 11607
11607
Annitton 14-20-54 14-20-54 14-13-54
14-35-57
14-36-4*
RESTRICTED INFORMATION
(R) Monaanto Stability Teat (Aa Chloridee in ppm.)
GENERAL INFORMATION
(R) f' (R)
Evaporation Loaa after 6 bra. O 100'C. (%)
Stability teat after 10 daye at 100*C. in glaee reeled in air.
0. T, max.
11503
0.2, max.
10116
No liberation of chlorine or chloridee
14-61-57 12-32-54
MOWS 047805
Monsanto
ANNISTON And KRUMMRICH FINISHED PRODUCT SPECIFICATION
AROCLOR DISTILLED 1262 use
ANN. b WCK 81107 -WCK_____
("T,Ann-2 1 WGK-241
Sales
MAR 02 1966
APPAOVAlt
1040-300-04/11/16-03-09
P. E. Heiler
{ill*
'
W. E. Ault ieiAiTOM
W. D, Robinson
.U.L,',
W. J. Gresham ci
D j. Dolm
1/24/62
PDA AnALTIII
pMuioTv
2 x 16 o*. W.M. Bottles
J. P. Prader
UNRESTRICTED INFORMATION
(R) Appearance <R) Color (R) Specific Gravity @ 90/15.5 *C. (R) Acid No. (mg. KOH/g.) (R) Viscosity @ 210'F.
GENERAL INFORMATION
Pour Point (ASTM)
Distilling Range
Total Chlorine
Specific Gravity Temperature Coefficient (85 - 130*C,)
Viscous liquid APHA 150, max. 1.572 - 1.583 0. 014, max. 86 - 100 SUS
35 - 38*C. 390 - 425'C. 61.5 - 62.5% 0.001/*C.
10084 10084 10114 10087 10086
MUNS 047806 (R) Routine Analysis, Alt others Analysed by request Only
MONSANTO CHEMICAL COMPANY
Krummrlch and Anniston , FINISHED PRODUCT V SPECIFICATION
"VVotiVcT (Ttmi* --)
PROOUCT COOK 82868
UM
IALU COOS
lOIPT. OR JOt IWOK 246 Ann. 2'
Sales
Issued
nil 15 19S4
w. Q v^Kruir^Ich^piant-
By
See Below TtPt
Montars 1 and 2 "PRODUCT
TYPO
Polychlorinated Polyphenyla
Mixture
MOL *T. wniimi inn or
6-15-61
IAMPI-1 Fe ANALYIU
g x 16 oz. W. M. Bottles
UNRESTRICTED INFORMATION Routine Tests
Specification
Anniston WOK Method No.
Appearanoe
Black Solid
14-17-52 11321
General Information
physical Properties (Typical Values)
Nontar X
Montar 2
Softening Point (ASTM E-28-51T) Acidity
54-l6o*C Slightly Basic
70-170`C Slightly Basl
Chlorine content
56-42)6
44 - 4856
CaO Pe Benzene Insoluble Flash Point
5-1536 O.5-I.O56 --------- ---500-620'F
5-1556 0.5-1.OJ6 12.5)6 ... -
RESTRICTED INFORMATION
Montsrs 1 and 2 sre the still residues from distillation of Aroclors 1042 and 1248 respectively. Composition of these Montars Is not controlled, being entirely dependent on conditions required to make acceptable dlBtllled product.
Sales Code Nos.
Montar 1 6405 - 001 - 04 - 03/09 Montar 2 6405 - 002 - 04 - 03/09
M0NS 047807
MONSANTO CHEMICAL COMPANY OROAMC CHEMICAL! DIVISION
Krummrloh and Anpiaton
FINISHED PRODUCT
PROOUCT COOK 82868
I DEPT* OR JOR Iwgk 2^6 Ann.27
USE
Sales ALE! CODE
SPECIFICATION PRODUCT (TreMa
*See Below TYPE
Montars 5 and 4 PRODUCT (CMaslMf Wan)
. TYPE
polychlorinated polyphenyla
issued JUL151964
W. 0. Krummrich P.iant By ~Yfi DT)),.L
1
mol rr. 6-15-61
Mixture
1AMPLE FOR ANALTMI 2 x 16 oz. V. M. Bottles
UNRESTRICTED INFORMATION Routine Testa
Specification
Anniston WOP Method No.
Appearance
Black Solid
14-17-52 115;
Oeneral Information
Physical Properties (Typical Values)
Montar 5
Montar 4
3oftenlng Point [Method A STM E28-51T)
se-ies^c
92-206`C
Acidity
Slightly Basic
Slightly Basl
Chlorine Content CaO
50-52* 5-10*
54-5656 5-1056 '
Pe
0.5-0.6*
O.5-I.O56
RESTRICTED INFORMATION
Montars 5 and 4 are the still residues from distillation of Aroclors 1254 and 1260 respectively. Composition of these MontarB Is not controlled, being entirely dependent on conditions required to make acceptable dis tilled product.
*Sales Code Nos.
Montar 5 6405 - 005 - 04 - 05/09 Montar 4 6405 - 004 - 04 - 65/09
<r
HONS 047808
23. Dept. 246 - Process Description AROCLOR APPENDIX C
PHYSICAL AND CHEMICAL DATA Physical Constant Data sheets which are available are listed following this page.
HONS 047809
PHYSICAL CONSTANTS DATA
niUTHIHT-- 1 '
! i i i
i-- "IitmucturaI formula '
R2601 DIPHENYL
TMnuo n,p, Metzner 2/12/43 'Ha'v.l *' 6/22/43. 1Zll/44. Rev. A.M. Ellenbung 6/26/57
FwiwH IblacylM WtM
tettUBBL. Blllin Paid 4 760 -- eUta
nlllm Paht 4 --
Wllnt Prill 4___B_ CiwUlllIlM Pdi4 IMIlf PalM
CgHs UfiHiT
265 C -iia
69, Q^C 69ur
oo
Bellateln V - 576
iouiiei PATK
cn*m.HUB66r him&mr~n-1641-42
Inl rrll Tahlra 1028 fSwann file 1137 1935
Swann Curve* 1934 Inl Trlt T.hl.. 1028
I^elllg ttinritv a___ 77/4..C
Swillt&ijjltf.f
Pwadt m 68.a
comidtm < Ewwiiwi
MuctKwWBt t
i Rid SwcUw ftotmct)
Ullta Villa Stadrua flliww)
Ylmtllr
more
mhsul.
70 129^2 C
hlitlllty 9 W8a
whip urn* Senxenc.jB 21
lathanol lr
0.8896 1 041 a 23 lha par gal.
D = 1.68822
Swann glia 4137* lain Int Crll Tahl.a 1028
29. 8 Say, Bee.
31.2 . 5 dyne/cm
Insoluble________________ 8..8go8-tg.a/nll nPPi ag. oauoilvYetmnt., C. K571 ga.. //110n0n ga.. aanaUlv.eawntl 1317 gf..//mlOOugg. aaoliventi
25.1 8. /100 g. advent
Swann glia 1127 A 1020
Int. CHI
Dow Seidell
Tahl.a 1928
1943 _1941_
15*1 1941
1941
nl> PM*F fin Hanot CaAmlgi
Ha l FaaMlon
dsirn r.up). nil (15)
sgaF - closed 'eup --apen eup---270
pan gm mnl a 1804 4
ma.~a Bng. -owm.--mo -MrM8 Swann.Flla 1137 A (1943)
Inl, Crll. TahUm 1928
UMtHUJlJf.____, fl-255-CCrtimi
136.5 BTU/lh^
43 BTU/lb 528aC- . 41 4 Aim ahanlnla
Swann Flla 4137 A (1928) RfcE CB 884 <1856) Rev.-Scl. Inal rnmenl 1,363
-flMO
28 8 gm.ral par gm
Lange Handbook 1831-
( 53.1 BTU/lhh
MUNS 047810
NOTE:-Fllea of W-P-Metanar. St. Loula
Twldly KMMlma. Klathl__m_ _nJ)l
1ItDk- I Pnkr>. WMeatL.e.ai ler Annlalnn Plant Report cnpv In
Synthetic Ufugi"
fi'--' :SD
liSi
CD*
PHYSICAL CONSTANTS DATA
( 2) rSKRIC CHLO^Da, ANHYDROUS
rA'w
Pc'-r.-S*!t Chcro.- Co. towtoit Pena-jSkit ChtmTCb.'
6-57
Found tolcculif Wclht
NAME , !
Boilins Point 1 7E0 tins ...
FeCL. 166.22
,
SOURCE 4 DATE Ttf 1
Ref-1-
Boilini Point H _m Mdf. uilllilm Point
Solution Poinl Soecitie Giovilv Specific Gravity Pounds per Gel. t
PC
Coefficient ol Emotion
Rclnclivt Index#
nt
Infra Rod Sooetrum
Ult Violet Swctni (Rtftrtnct)
yi entity _________ ,_________________
ViKOSitV #
Sublime a
MiQlllly In wan Sol utility in
Soliftlllty In
..____________ V. Sol. Ihont rinel_______
R.f.l.
Flh Point 9F fUahodJ
Fin Point C Ufilit of Combustion
,
.
He ol femillen
Therail Sialllly Icil.Al/'inilO_________________ HLent Heat of Fusion '
Latenl Heel of Vio.
'
Sotclllc Hell
,
Cillltol Tnotfitin
V"
*1 ' "*,*"R<ftye..ic4 *.
LC>i o
jrenn-djui v nem. co. Tecn. Data Shea .It Spec*.
ToxititV fdvt Rtkrtnet)
moms 047811
'yC'T-C-.-T^rMr^fttn^hvnlH-nfu^t Yrlmttd BMitrfr f Manimttf Chtmltal
Ou idditienat aktHt if ntttuvy. .
CD*** *i* 38800 PHYSICAL CONSTANTS DATA
HYDRATED LIME (Cslclum Hydroxlfc)
A *** 1-25-57
FonmU Moleculu WlIlM
mAmc
BaIIIm Pair! (KOh Mltatfemt
bi Bel IIm Point M m
CivsiiIIIzIm Point
m
tokleillJoHnt
PotiH Giovihr
#
. 20^C
toiiclllc GisvUff Pm) p Gil. * 50 *C
CnHidint * Ekmwm
ftitiKtln Mu
:
Mil Rtd Swell* IHttfmn)
Utlll Vtold SNdlMI tKHtrma)
Vlauiltv *
Vlccetltv
Sri Sil lAIIRv In VMa
\ Seldtllttv tn
Mitllllv In
OOUWCK 0 PATO____________
Ce(QH).____________________
Ref. 1______________________
74. ID *____________________ ___ Ref. 1______________________
Whits pnuirlsp
Ref 2
DrnmpojiAA
2.2
4 D 1.574. Ed 1.545
Ref. 1 Ref. 1____________________ _ ___ Ref. 2_____________________ _
___ Rei--1______________________
.185%ftOC. .077*8 11 DC Ref. 1
'
Soluble In eclds end WH4 :i Ref. 1 _
Flash PiW P /m*m\
Fin wm K Uti Dl CiriMiittan Hll1 si FsmttaL ______________________
Tlumil StollltY (eS-Au/iln.)
Lint HiM sl FalM , Lrtml HiM iIVmi.___!______________________
SmcKIc HlS
Critlcil Tsmntm CrHIcil Pratnot
_.
Bitigrl^lm flee*
References;
2. JnfoPrpotlon bv Vendor
1
i
U
i
o
. 1B5R
ToslcHv ta<* n,i'r,wi
_ HONS 047812
tr ... PHYSICAL CONSTANTS DATA
CHLORINE
'
T OUPILIBIV
9*j4
W. H. Demeree
WAMI Ftiwrtl Wrote Wrtt______ ___________________
7-29-54 ~70IJ
tQUBCt 4 OAT________________
ADUttttfll______________ ______________ _____
fillliMfelftlMM . tlllNfeM *100U '
... ..
t
34.05 -71. Ji
_AP1___________________ ___ Ref. 1
-100.04
Ref. 1
-rxrM------------------------------ Ref. 1
imlilUilM Nft
H
||i/iiIm hin
,
iXS,. O'CHM
ss; m
---------------------
Funds p*m.# ] c
-100.44
1715 1.404
Ref. 2
Ref. 2 Lenee
CrtlHctel d EnmlM
r ffiettaMat 0*Cj
*i
(1 11M toictnrt 2rtMI
Ultfi VMft IdnImi/K^vmmJ
ICAlltV
,
.
1.47
Ref. 2
VI cull**
la * tirilttr It fi & tftlifrJd
Solicitor fc----S&ec.lflc erayltv a J0*0
1.377
Flirt Pote F llutti}:
s tPiw'c
;
111
Hi
III
u ert Hut tf Fialtt |
LM MtttaMafVu.
Sdelite Hut
j
CdUtil Taturtn j
Ctl Iril Pimm* !
cu imMIm fiaMlal |
*
KeF. 1 - Calc. from det. date
1 us 1 o
' cHy I'CfW Ktfrrtbi)
144*C 76.1 ttmAfl.
Ref. 2 . Rftf. 1
HONS 047813
PHYSICAL CONSTANTS DATA
TcMflwer--' AROCi-OR
TDMFTETD1V----------
A. M. Ei.fr bora _____ NAMNEAM^
f oiimili itoliculu Weijht ____ __________
Awuuitu______________________
Boilini Point M 780 m Rnte
Belli Ejuj j( 3 m
"
Baling fan* 8 _n ----------- --- Bsiiu* foil ,.j*i _________
!ystilliijjV PoM..... ......................... IfcJljj* Ptuol _________ __________
SsUudPtinl Sjwtilit ChhIy ^$7 25 C.___
ScKilii CwilK 25/15.5-C, Poundl ptlTlI. 25 %
CoiWiciMt ol Emumon 25-65 'C.
Rilntiivo iiidiii2VC. o l
Mil Rd Swcliw iR'iw**l
Ullil Violat Spedfun (Htfmtnctj
Yiiwltof ...'ilSi'U
jVjlikcvoMntuv J- i*0r0" . ...-------- --....... SuUfiMilBi Dyff/cm 6 ZO'C. SoliiiltHY In WUr kllOllltyJn. 3A~Aitc-.ol @29C.
ScliRiltlv in Pyr dir.f __ @ 10C.
i'oaTV ` 1..
CelPiitat-Mol:
325 - 160 C.
No" c rviialliairg
_L._38Q_ 1. 381 - 1. >92 11.50 1.62-15 - 1.6265
J4rJ5_SilS_ 45.1 . Ir tr: .bIt 23. 3 g./IOQ cc 1 32 5 8./IHQ cc_
,---------------- u, ------- lauaiijLBAii. .
iLmoi. Bui!. UP 3
935;
2Ui:= 55_____ M. B. OP-1.5
Sprtf fit'll- _2. J 4.56
M. B. QP-iiS ____ u _ _ _____
.U -CiU. Sci..
lfi-. J 952
M. B. OP-l '6
flirt Point HfikUioH E.o.c,
Fin FoM^C
c o.c,
Hilt ol Contiatlon
HW oi fWWUrt
IMM ssilffir Icnym-'nli'.)
Utnl H*8 of FjbIm ______ LnamtRny*,.ci>1/pro,_
Smith HU gc,____
Clllicrt Tww&fMtffC
CmicH Pttmie
Pr>,,r pr;r e rm* Conductivity, cal/
_____ __________ cm/ C/oec.
D e ec* r;c Gorta- jOO 60 cy.
180 C. Ncnr
61____ 0.29?
0- >*0 1 4 1 C . c.r lonn 24,0 e 2* C.
4.3 -4.9
L CAjcuIiltd____________ M B. QP. 16________
I-L'Jie p..ii. jj
OP~i~A~iL~
Tonicity (Civ* Htftrrntt) _
Con'aci Medea Dpi/
HONS 047814 Q.-2J_S.____
t
I3> PHYSICAL CONSTANTS DATA
TflTTcTuR AL^ORMUL A
( ceumiBiY
A. M. Ellenburg
FoomHi Mo tttllftt WoltM
naMi
BoIIIm Poll* S 7(0 aa Bo
fto Bs lint Point a mn s itaiiiino Point Ik So itlon Point
Ranee n
a
d NlA s *NA a
iss
1a
Sooclllc Ginllv 65/15.5VC. round* por Gal. * 25 C
Corilicionl o1 Ewauion !R-6R0r
Rotisctin Mu*
!S"r" i
Ini i Rod Soectfua IRifmoci)
Oilto Violet Spodnoi (Htftmni
Vlncoolb#
lpOF.
YncodtY*
su SolItillltv In WSa Solilillitv in 3A Alcohol 6 25UC.
Sol utility In Fyrld(n* 0 29UC.
bill 4-2f 57
C12 HR Cla 292 (Ave.) Y#11nw Tlnt^ri Mnh Oil 345-385C. 185-2IODr
ci. ______ tOUaCC PATE
Monsanto Bull. OP-115(1 !' St It
Non-crvstalllzlnff
II
1.445
1.405-1.415 12.04 0.00070 cc/cc/uC. 1.6285-1.8305
IS SDec Ifteat Ions 9/9/54 M.B. OP- 115
SDeclfleatlon 9/9/54
73-80 BUS
44.2 Insoluble 15 g. /100 ce 111.4e./100 cc
M.B. OP-115
J. CoU. Scl. 7.166.(1952 M.B. OP-115"
SI
Fiiah Point PK/UuMJ c.o. c.
Fir#P*WC HUit at ConfaiutlM
c. o. c.
Hsi of Fotadlon
,
IISimp Stkllity tcoi.Ai/aln.) LMent Haat ol Fiaion
LMffilHiMot V. cal/gm.___________
SokHIc Han A 25UC.
Cilllcil Taaottohn
.
Cillical Pianino_____
Oilnoelitlon Comtirt
_______________
Sr eelfie Heat 0 &00UC.
196r.' None
54 0.277
0.358
Pour Point
0C. or lower
>
Thermal Conductivity, cal/ r cm/vC/sec.
23.6 S 28V
im Dielectric Constant. 100"C..
u ta cy. ______
4.5-4.7
Ii
o
M "
Calculated M R. OP-11S
n-------- ----------------------------------------
IS To be Dubllahed M.B. OP-115
TOXiefiV (Civ* Rtftrtnct)
Contact Medical Dept, --M.B. OP-115
PHYSICAL CONSTANTS DATA
luimut* 1
1,1 rTT 1
"
... ITRUCTUMAL OohMuTa
ABOCL.OR I?54_________________________________
(SHFIIID IT
A.M.EUerbjr*
na|mc
Famuli
MdIkuIm ieiilK
Aa fia liM Pair! M160 ML DotllaiPiilid M 3 h
Rarge "
W lino Point M qrtAlliino Paint Ik SolMen Point teaclfic Gravity Specific firovllye
Ml oat Ml
saa
25>/2SwC. 65/15.5C. Ak
CotlficloM<D Emersion 25-65"C.
HofioctlwMu* , >r*i
Mia Rad Seadnen tmitmal
Dili* Viold Saactiwa iMtmai
Vlautilv
210"F
Vluaiitv #
mo TsmIm
Dvnes/cm
tel JH'Ittv ia M*
._
telifcihtvin 3A Alcohol 627WC
WiWWyIb Pvrldlne A 31C.
DAT!
_ 4 25 4T
Cl? HaClt, ______________
326 'Art.)__________________ Pal* Yellow ls-D-a oil 365-40iC iao.??nr
touweg a PATt
Monsar, o Ral' OP-llHl95f M
Non - c r v sI.bIaIz In a
II
1-536________________________
1.495-1.505
12.82
,,__________
0 00068 cclcc/~C. 1.6370-1.6390
Rpr lf r*Hr>r x 2/\4/SV
MU QP.1
'
Snrntf(ration 7/14/56
44-48 SUS
MB OP- 115
50.3a2bC. 42.0fll00u *a
Insoluble
10 g./lOO ec______________ 114 e. /100 cc
ll
It M II
flash Point*/Started/ C. 0. c.
flra Point C
c. o. c.
Ikl
Hf at FanaMon intrail Sltellltvfcal./iu/'Bift.)
LAMl Hula/Fmi* '
1,6 ontHodotVai. Settitle Had
rl/grn 6 2iT'c.
CtH leal Taneefitiin
Critical Pratura
None Jimt_________________________
II
50 0.261
Calculated MB OP-115
t relflfc Hr.tt- B 300 C.____________ 0.336________________________
Ppur Point .
m Vm
TVermdl Conducttvtt. Cal/ cfn/6ClSec.
g 9Rr
r
II | To be Dublished
i Dielectric CoMi'an!. 100C. 0 6 b cv.
1 o
4.15-4.35
MR - OP -1 lf> HONS 047816
TexlcHv Afepnc;
Contact Medical Dept.
M B - OP-115
PHYSICAL CONSTANTS DATA
PHYSICAL CONSTANTS DATA
`lURVIuift 1 1 .. 1
STRUCTURAL FORMULA
A ROC LOR 1262
(Ki
'
TBMP1UB ______ A. M. Elltnburg7/3/57
DAT!
ci7
Formula Molttula MW*
NAME
BoIIIm Polfl 4 760 M lira Poll! a
<-i7h3ci7________________________
IQUACg 0 DATt
Llyht veil, ntteky Rnntn 390-425C
Monnnntp Bulletin OP-1J5 " (1956
fin BoiliM Palm 8 *4 cmwililv Point ______________________
Ifal Solillon Point Sooclllc Giovltv 80/15, S"C
Sncitic Gravity 25/25C Pound* pa Gal. * ax C
Cooltldont d twanlon 25-rso RofiictlvtMai jS5r i Mi Rat Saactnan rituinM/
Ultii Violat Sooctna nktfrmcii
VlKOllly 0
21 QF____________
Yilentity
{ii
fel Ulllty in Ha
felliMIltv In So) Alltty ll
1.577-1.567 1.64$
13-72______________ ,,_____________ 0.00064 cc/cc/l'C 1.646-1.650___________________
SDecs. 4/11/55 MR n^.nx______________________
Afi.tfin SITS
Specs. 4/11/55________________
Flnlt Paint F mrnhpil
FlraPointC tlH tl emanation
.
Hti ot Bunion__
TtwiMi ability(MLAi/alflJ____________________
LImt Hta ol Ptalon limlHaMof Vid. '
SHtitle Hut
cm IcnlTanonrAn cm ten Pittuit , Dllrelation CooMat ptur Point
Nona None
25-38C
MB OP-115__________________ (1
< M I u MONS 047818
i
Toilcttv fGivt Rafaranta)
Contact Med. Dept.
MB OP-115
NOTE: Then fata ikoaU w( * rataat ad muM*
CIU(tal Company. Ut additional
(/mhk^.
2b. Dept. 246 - PyocesB Description AROCLOR APPENDIX D
UTILITIES The utility calculations are based on design calculations for a 28.8 million pounds per year production rate. The breakdown of utility usage by Individual equipment Is only on estimate. The estimates of utility usage are average values In most Instances as It Is difficult to measure the operating time and load for a particular piece of equipment with great accuracy. The total usage of each utility was taken from the cost sheets. Estimates of Individual operating time and percentage of the total load were made to calculate the distribution of utilities as given In the following pages of this section.
(
HONS I
Dept, 246 - Process Description
AROCLOR APPENDIX D
UTILITIES (Cont'd.)
25.
1. Power Consumption
A. Electricity - 440 V., 3 phase, 60 cycle
Item Equipment No, Motor
Motor HP
Peak Load
KW
101 Biphenyl transfer pump
103 Biphenyl head tank pump
104 Biphenyl feed pump
3.00 .75
7.50
2.6 0.7 6.6
Monthly Usage KWH
80
240
1980
121 122 123 124 125 127 129 132 135 140 141 144 149 151 153 155 157 170 174 180
#5 Chlorlnator pump #4 Chlorlnator pump #3 Chlorlnator pump #2 Chlorlnator pump #1 Chlorlnator pump #2 Blow tank pump #1 Blow tank pump #1 still pump #2 still pump #1 Receiver pump 2 Receiver pump Blend tank pump #3 Storage transfer pump #4 storage transfer pump #5 storage transfer pump #8 storage transfer pump #7 storage transfer pump #1 city water pump #2 city water pump Exhaust blower
Miscellaneous Totals
10.00 8.8
10.00 10.00
8.8 8.8
10.00 8.8
10.00 8.8
5 .00 5.00 5.00 7.50
4.4 4.4 4.4 6.6
2.00 1.7
2.00 3.00
1.7 2.6
3.00 2.6
3.00 2.6
3.00 2.6
3.00 3.00
2.6 2.6
7.50 6.6
7-50 6.6
15.00 13.0
135.75 119.8
3040 3040 304 0 3040 3040
200 1580 1580 2340
20 20 200 160 240 200 80 80 2340 0 0 26,860
HUNS 04V 82Q
Dept. 246 - Process Description
AROCLOR
APPENDIX D
UTILITIES (Cont'd.)
1, Power Consumption (Cont'd.)
B. Electricity - 110 V., nne phase, 6o cycle
Peak Load
Equipment
KW
Lighting
15
Instrumentation
2
Miscellaneous
.2 Natural Oas
Totals
20
Item No.
Using Equipment
Normal Use SCFH
Peak Use SCFH
131 #1 Furnace
1200
132 #2 Furnace
1200
Totals 2400
2400
2400 4bo6
3. Compressed (plant) Air
Item No,
Using
Normal Use SCFM
Peak Use SCFM
127 148
#2 Blow Tank #3 Storage Tank
60 60
200 200
150 #4 Storage Tank 60
200
152 154
#5 Storage Tank #8 Storage Tank
60 60
200 200
156 #7 Storage Tank 60
200
Miscellaneous Totals
10 370"
200 ITOT
26.
Monthly Usage KWH_________
3600 1440 2150 7190
Monthly Usage MSCF 430 430 boO
Monthly Usage
MSCF 2590
90 90 90 90 90
MONS OA7821
Dept. 246 - Process Description
27.
AROCLOR
APPENDIX D
UTILITIES (Cont'd.)
4. Nitrogen
Item No.
Using Equipment
Normal Use SCFH
Peak Use SCFH
Monthly Usage
SCP
142 143
146 147 148
150 152
#1 Blend Tank #2 Blend Tank
#1 Product Tank #2 Product Tank #3 Storage Tank
#4 Storage Tank #5 Storage Tank
Totals
3 3 3 3 3 3
&
4 4
4 4 4
4 4
23"
2140 2140
2140 2140 2140 2140 2140
14.980
Purchased Water
Item No.
Using Eauloment
130
131 203 204
205 206
#1 Still #2 Still #1 Vacuum Jet #2 Vacuum Jet #3 Vacuum Jet S-K Drowning Jet Miscellaneous
Totals
Normal Use 0PM
3 3 20 18 15 25 2 "BE"
Peak Use QPM
5 5 20 20 20 30 10 TOT
Monthly Usage M. Oal.
150 150 870 770 650 120 100 2810
High Pressure Steam
200 TSlfl at' 3B8F
Item No.
Using Equipment
167
203 204
205
#1 Blow* Tank #1 Vacuum Jet #2 Vacuum Jet
#3 Vacuum Jet TotalB
Normal Use Lb.Ar.
210 450 400 325 1385^
Peak Use Lb .Air.
310 670 615 500 2095"
Monthly Usage M. lb.
150 320 290 240 100O
7. Low^Pres sure^S team
Item No.
102
138 139 142 143 146
Using Eaulment
Biphenyl Storage Tank
#1 Receiver Tank #2 Receiver Tank #1 Blend Tank #2 Blend Tank #1 Finished Prodi
Tank Trf.n 1 a
Normal Use Lb./hr.
700
700 700 200 200 200
2700
Peak Use Lb ./hr.
900
' 900 900 300 300 300
3800
Monthly Usage M. Lb.
500
500 500 150 150 150
T9S0~
MONS 047B22
28.
Dopt, 246 - Process Description
AROCLOR APPENDIX D
UTILITIES (Cont'd.)
7. Low Pressure Steam (Cont'd.)
Item No.
Using Equipment
Normal Use Lb ./hr.
Peak Use Lb./ir.
Monthly Usage M. lbs.
1*17 #2 Finished Product Tank
200
148 #3 Storage Tank
700
150 #4 Storage Tank
700
152 #5 Storage Tank
700
154 #8 Storage Tank
700
156 #7 Storage Tank
700
Miscellaneous
1400
300
900 900 900 900 900 2800
150
500 500 500 500 500 1000
Totals
7800
10,500 5600
MONS 047823
Dept. 246 - Process Description
29.
AROCLOR
APPENDIX E
PERSONNEL
Departments 246, A-246, B-246 and C-246 are closely related. Operating personnel may work In all of the departments In a given day. For this reason, the description of operating classifications and assignments for departments 246, A-246, B-246 and C-246 Is given as though all four of the departments are Just one department.
Operating Classifications
Job
Premium Operator Second Operator Repairman Standard Operator Porter Swingman
Number of Men
7 day/week Schedule
10 & 4 Schedule
43 43 i1 22
ii 10
TOTAL
12J 9i
The swingman works two shifts per week (Saturday and Sunday) as a relief foreman, two shifts as a repairman, and one shift operating the premium Job. There 1b an open shift on the second operator Job that Is covered by overtime. The premium operator and second operator cover three shifts each (Jay. The repairman works the day shift, and with the Bwlngman,
there Is 7 days per week repairman coverage. Standard operators work the day and middle shift 5 days per week. The porter works half time In department 246 and half time In department 243. The premium operator has
lead responsibility for his shift.
The work force works all three departments Aroclor, Pyranol and Pydraul as one coordinated operation. The assignment of time Is 70# to Aroclors, 15# to Pyranol and 15# to Pydraul.
Operating Assignments:
MUNS 047824
Premium Operator: Has overall responsibility and operates 5 chlorlnators 2 stills and covers the necessary absences of the standard operator.
Second Operator: Operates 2 blend tanks filter, 2 finished product tanks, storage tanks, makes Pyranol and Pydraul mixes, loads trailer, and tank oars, charges chlorlnators and transfers receivers and also
belongs to the Fire Brigade.
Repairman: Unloads cars and trailers of Biphenyl, Trichlorobenzene and Tetra-Trichlorobenzene and finished product, makes weekly safety lnspectlot
30.
Dept. Sk6 - Process Description
AROCLOR
APPENDIX E
PERSONNEL (Cont'd)
Standard Operator: Fills, stencils and labels 5 gallon, 30 and 55 gallon drums and clean-up asslgnmenta when not drumming. The Standard Operator loads cars and trailers as does the second operator.
Porters Cleans office, control room, repair room, wash room and smoking shelter.
Swlngman: Works one day per week as premium operator, two dayB as repair man and two days as relief foreman. As relief foreman takes overall supervision on day shift on weekends including arranging for maintenance, night sheets and line-up of work.
<
( MOWS 047825
Dept. 246 - proceBa Description
31.
AHOCLOR
APPENDIX F
PACKAOINQ & SHIPPINO
Aroclor, Pyranol le Pydraul and filled about half in drums and half
in tank care or tank trucks.
A substantial amount (about 40) of Aroclor is used to make Pyranol and Pydraul.
Sales are largely directly to the customer. The remainder is in bulk shipments to the J. F. ftueeny Plant.
All electrical grade tank truck shipments are made in the customers trucks whloh are stainless steel. Non-electrical Aroclors are shipped in leased trucks and may be iron although other materials of construction are suitable. Pydraul is shipped in steel tank trucks.
Electrical grade Aroclor and Pyranols are shipped in solid aluminum lined tank cars or in lined tank oars either 4,000 or 8,000 gallons
in capacity. The lining is either tin, zinc or aluminum spray because iron and iron oxide contamination is detrimental to the electrical properties. Electrical grade cars are either owned by Monsanto or on a long term lease. Non-electrical grade Aroclor is shipped in
Bteel cars.
All electrical grade lots and bulk shipments of non-electrical material are sampled from the final container. That is all tank cars and tank trucks are sampled and analyzed after loading. All electrical grade drums are sampled from one of the drums.
Tank cars and tank trucks are inspected to be sure they are free or dirt and water or other foreign material before loading. HeelB are drained before loading some materials. Car washing when necessary is done by the repair track. Tank cars are sealed with a numbered
aluminum seal.
MOMS 0 4 7 B * 6
Lacquer lined drums are used for Aroclor and Pyranol and plain steel drums are used for Pydrauls.
A summary of products, weights and containers current use is as
follows:
Weights and Containers
Product
5 Qal. ICTfaT-------~5TTJar------ TT
TC
1232 1242
1248
1254 1254 Xylene 1260 1262
..
55 . 60 _ 60 -
--
60 _ 60 _
600# 600#
600# 600# 600#'
600# 600#
Yes Yes Yes
-
Yes
-
_
Yes Yes Yes
-
YeB
-
MCS295
-
-
645#
--
Pyranol i486
-
-
675#
--
Pyranol l48l
-
-
675#
-
Det_1_2f|6_=_Jroce8B_De8orlj2tln
AROCLOR APPENDIX P
PACKAOINO & SHIPPINO (Cont'd.)
Product
Pyranol A-13B3B Inerteen PPO
Pydraul A-200 Pydraul 280
WeiKhtB and Containers 5 OalT------ 30 OaT.------- 55 Oal.
|5
36#
IW,
6o 360#
59 6o "
645# 625#
TT
-
-
YeB -
TC
4000 Oal. 4000 Gal. 8000 Oal.
HONS 047827
Dept. 5*16 - Process Description
AROCLOR APPENDIX 0
MATERIAL BALANCE
33.
The material balance on Dept. 246 was made with a minimum of field measurements. Most of the estimates on the following page check fairly close with actual raw material usages that can be readily measured. The exact composition of some of the Inter mediate process Btreams Is uncertain.
(
MOMS 047828
Dept. 246 - Process Description
AROCLOR Appendix q
SUMMARY OF MATERIAL BALANCE RESULTS
AROCLOR 1242
Raw Material & Cost ($/lb.)
Usages - Lbs/100 lbs product Material Balance
Theory Material Balance
Usages lbs/100 lbs
Biphenyl (.0662)
58
63 58 Finished Prod. 1 Filter Cake 3.5 Still Bottoms 5 Off-Oas HC1
63.O
Chlorine (.0217)
84
91.8
42 Finished Prod. 1.5 Filter Cake .05 Vacuum Jet 2.8 Still Bottoms .95 Alr-HCl Mix ture
44.50 Off-Oas HC1
91.80
Ferric Chloride ( .129)
0.03
Attapulgus Earth (.0302) 15
Air (.00055)
3
Lime (.0100)
0.5
03 .15
3
0.5
.03 .15 3.0
0.5
AROCLOR 1248
Biphenyl (.0662)
52
56.5
52 Finish Product 1 Filter Cake 3 Still Bottoms .5 Off-Oas HC1
56.5
Chlorine (.0217)
96
103.2
48 Finished Prod. 1.5 Filter Cake .05 Vacuum Jet 2.55 Still Bottom: .95 Alr-HCl Mix ture
50.15 Off-Oas HC1
103.20
HONS 047829
These raw materials are the same for production of all Aroclors
1. Dept. 246 - process Description
35.
AROCLOR APPENDIX Q
Raw Material & Coat (i/lb.) Biphenyl (.0662)
SUMMARY OP MATERIAL BALANCE RESULTS (Cont'd.)
AROCLOR 1254
Usages - Lbs/100 lbs product Material Balance
Theory Material Balance
Usages Lbs/100 Lbs
46
49.8
46 Finished Produc
0.5 Filter Cake
2.8 Still Bottoms
0.5 Off-Oas HC1 49^8
Chlorine (.0217) (
Biphenyl (.0662) Chlorine (.0217)
108 117.5
AROCLOR 1260 40 43.4 120 128.8
54 Finished Produc 1 Filter Cake 0.05 Vacuum Jet 6.8 Still Bottoms 0.95 Alr-HCl Mix ture
54.7 Off-Oas HC1 117.50
4o Finished Produc 0.9 Filter Cake 2.0 Still Bottoms 0.5 Off-Gas IIC1
43.4
60 Finished Produc' 0.5 Filter Cake 0.05 Vacuum Jet 4.8 Still Bottoms 0.95Air-HCl Mix ture
62.50 Off-Gas HC1 128.60
( HONS 047830
36.
Dept, 246 - Process Description
AROCLOR APPENDIX H
ATMOSPHERIC DISCHARGE - WASTE DISPOSAL
Lbs. per C lbe.
Total LbsAr based on
of Aroclor Produced
1. HC1 Fumes from blow tanks
0.01
2,000
2. HC1 fumes from other tanks vented to atmosphere
3. Chlorine gas from chlorlnator vented to blow tank
0.01 UNKNOWN
2,000 UNKNOWN
4. Aroclor & Biphenyl vapors of tanks vented to atmosphere
UNKNOWN
UNKNOWN
DlBOharge to Sewers
1. HC1 from chlorlnators 2. CI2 from chlorlnators
2.5* 2.0*
500,000* 30,000*
3. Condensibles In chlorlnator off-gas
2.0*
30,000*
Discharge to Waste Disposal 1. Montar 2. Aroclor
0.0176* 0.33*
5,000* 95,000*
Estimated
HONS 047831
Dept, 846 - Process Description
37.
AROCLOR
APPENDIX I
PROCESS CONTROL
Sampling Point
Frequency
Reason for Normal
Sample
Range
Method Number
Chlorinators 2-3 times per batch
Specific Gravity
.011
Blend Tanks
Storage Tank Composite Tank Cars & Trailers
3 times eaoh day
Every 1-2 days
Color (APHA)
50-150 Max.
Sp.Qr. at 25/15.5C .011
Acidity (mg.KOR/g.) .014 Max.
Moisture (HpO) (PPM) 35 PPM Max.
Refractive Index at
25C
.0020
Inorganic(freeJChlorides .05 PPM
Max.
Dielectric Constant .20
Resistivity (500 VDC 0
100C
500, Min.
0.1" OAF as ohm-cm x
109
Hydrolysis Stability 1.0 PPM
Test (as Chlorides)
Max.
Monsanto Stability 0.5 PPM
Test (as: Chlorides)
Max.
Sulfates
None
Dielectric Strength at
25C
35 KV Min.
Viscosity at 100F
(sus)
10
Thermal Chemical
0.75 PPM
Chlorides
Max.
Same as blend tanks
Every Load
Same as blend tanks
10,084 10,114 10,087 10,620
10,125 T-2092 11,608
11,607
T-2087
11,503 12,169
11,605 10,086
12,722
HONS 047832
Testa made on electrical grade Aroclors only. . Tests made on request only. Special oustomer test. Maximum range for all Aroclors Including electrical and non-electrlcal
grade s.
Dept. 246 - Propose Description
38.
AROCLOR
APPENDIX J
SAFETY AND TOXICITY DATA
SAFETY EQUIPMENT
The following is a list of safety equipment (personal and departmental) required in department 246.
1, Fire extlrigulBhers:
A. Dry Chemical (3) - Southwest corner Bldg. CR - Main Floor
- West wall at top of Btairs of second floor.
B. Carbon Dioxide Snow - Southwest corner of Bldg. CR, ground level. 2. Chlorine Qas Masks(4) - Southwest oorner, second floor
- Control room, second floor
( - East side, outside control room
- Wall, Southwest corner of sprinkler house, main floor.
3. Scott Air Masks - West of Lean-To 4. Safety Showers (2) - Southeast corner of Bldg. CR, ground level.
- Southeast corner of Bldg. CR, 2nd floor.
5. DaviB Vapotester
6. Eye Baths
7. Sprinkler System
Safety Precautions
The following are safety precautions followed in the operation of department 246.
1. Safety Equipment of Employee Each employee haB the following safety equipment: (l) hard hat
( (2) safety glasses (3) goggles (4) rubber and canvaB gloves (5) rubber overshoes. Special equipment may be Issued as necessary for performing a particular Job in a safe manner.
HONS 047833
I Dept, 246 - process Description
39.
AROCLOR
APPENDIX J
SAFETY & TOXICITY DATA (Cont'd.)
2. Sampling of Crude Aroolor
The earnpie8 of Aroclor taken during the chlorination reaction are hot (170C). Precaution must be taken to avoid Bkin contact of sampleB and inhalation of hydrogen chloride, chlorine and
aroclor vapors.
3. Fires Fires may result from the ignition of leaking gas, xylene, diphenyl, rags, paper, wood, etc. Automatic fire extinguishers and sprinklers have been installed to combat fires.
4. Explosions Explosions may be caused from accumulated pockets of natural gaB or a rapid burning of Diphenyl in a oloBed container such as
a ohlorinator. Chlorinators are equipped with a 10" diameter pressure relief line with a rupture disc madeto buret at 22 psi in case diphenyl within the chlorlnator ignites.
5. Toxicity Toxicity does not present a serious problem. However, a com
( plete dally change of clean clothes iB supplied to each person and time is allotted at the end of each Bhlft to take a bath. Instructions are also Issued to avoid actual skin contact with
Biphenyl and Aroclor as much as possible and to wash hands and faoe before eating.
6. Miscellaneous There are many accidents that can occur that may be classified as health and safety hazards. These accidents may result from such things bb broken process lines, acid leaks, steam leaks, etc.
The worst inherent hazards are as follows:
1. Free chlorine from ruptured line or major leak. 2. HC1 gas from ruptured line or major leak. 3. Dropping bottoms from Btllls. 5. Hot aroclor and diphenyl.
Safety Record
The last loBt-time injury in Department 246 was January 28, 1948. The frequency of minor injuries 1b low, around one per month.
Toxicity: ThiB material is a liquid under normal conditions and has a
medium toxicity range for liquid ingestion and high toxicity for vapor
(
inhalation. The maximum allowable concentration (M.A,C.) is 1 mg/cubic meter.
Fire Hazard: There 1b no fire hazard under normal conditions. Aroclor mixes (Xylene, Toluene, Butyl Acetate, etc.) may burn and explode at high temperatures when exposed to flames.
MONS 047834
Dept, 246 - Process Description
AROCLOR APPENDIX J
SAFETY & TOXICITY DATA (Cont'd.)
4o.
Other Hazards: This material can cauBe dermatitis, systemic poisoning from the fumes, and yellow atrophy of the liver. There are skin, mucous membranes and eye hazards encountered in handling this material.
Treatment and Antidotes: Call a physician and remove patient from fumes.
Storage and Handling! Proteot the skin, lungs, and eyes by wearing approved protective clothing, respirator, and goggles. People who handle this material at elevated temperatures should have medical supervision, and the air should be sampled to Insure compliance with H.A.C. There are no special storage restrictions under normal conditions except store in a ventilated area.
Shipping: There are no speolal shipping restrictions,
FERRIC CHLOftlDE (FeC^)
Toxicity: This material is a solid under normal conditions and is nontoxlo or has a rating as low.
Fire Hazard: There is no fire hazard under normal conditions, but it will emit toxic fumes at high temperatures.
Other Hazards: Some people are allergic to this material and may develop skin rash, and there is an eye hazard.
Treatment and Antidotes: Call a physician.
Storage and Handling: Protect the skin with approved protective clothing, avoid the breathing of FeCl3 dust, wear approved respirator with adequate cartridge, and proteot the eyes with approved goggles. There are no Btorage regulations.
Shipping: There are no shipping restrictions.
DIPHENYL (CgH5CgH5)
Toxicity: This material is a solid at normal conditions and 1b medium toxic. The M.A.C. of vapor is a 2 mg/cubic meter of air. If Ingested, the lethal dose is 2.4 g/iCg of body weight. The fumes are not dangerouBl deadly, but they are poiBonous over a prolonged time.
Fire Hazard: Diphenyl is very flammable and will burn when exposed to heat ol' flame or oxidizing materials (F.F. - 120C).
Other Hazards: Diphenyl is not too corrosive to skin, but it will affect the eyes.
MOWS 047835
c
I
()
I I
('
Dept. 246 - Process Description
4i.
AROCLOR APPENDIX J
SAFETY & TOXICITY DATA (Cont'd.)
DIPHENYL (CsHjCgHj) (Cont'd.)
Treatment and Antidotes: Wash eyes with water and set the patient to fresh air. TryTTo get patient to vomit, and call a physician.
Storage and Handling; This material can be stored In steel containers away from l'lre hazards and oxidizing agentB. Wear suitable clothes and approved goggles when handling diphenyl.
Shipping: Ship In cars or other suitable containers with a red warning label of flammability.
XYLENE (C6H4(CH3)2
Toxicity: This material Is a liquid under normal conditions and Is very toxic in liquid or gaseous form, but it Is less toxic than toluene. The H.A.C. Is 200 ppm.
Fire Hazard: This material is very flammable and the limiting explosive concentration is 1-5.3# by volume in air. It will also react with oxidizing agents (F.P. -85F).
Other Hazards: This material will cause necrosis if enough is Inhaled, and is hazardous to eyes, mucous membranes, and the skin.
Treatment and Antidotes: Get patient to fresh air, and call a physician. Tf injested, get patient to vomit. Wash eyes and skin with water.
Storage and Handling: This material should be stored in a cool wellventilated area away from fire hazards or Btrong oxidizing agents. The material for storage can be steel oars or tanks. Wear approved protective clothing, respirator, and goggleB.
Shipping: Ship in containers of steel or appropriate material with a red label.
TRICHLOROBENZENE:
Toxioity: This material is a BOlid at room temperature and the vapors are quite toxic. The solid is poison if ingested. The M.A.C. is 50 ppm.
Fire Hazard: This solid 1b flammable but is listed only as a moderate fire hazard. Will burn at 420C or above.
Other Hazards: This material will affect the liver, eyes, and mucous membrane s.
Treatment and Antidotes: Wash eyes with water, and get patient to fresh air. Call a physician.
HONS 047836
( Dept. - Process Description
1)2.
AROCLOR
APPENDIX J
SAFETY & TOXICITY DATA (Con)
THICHLOROBENZENE (Cont'd.)
Storage and Handling: Store thiB material In cool, well-ventilated area away f'rqm hazards and oxidizing agents. Wear protective clothing, chemical safe goggles and approved respirator.
Shipping: Ship in steel containers like cars or tanks with red label.
TETRA-TRI-CHLOROBENZENE
Toxicity: This material is a solid at normal temperatures and is medium toxic. The M.A.C. of vapor Is 50-75 ppm.
Fire Hazard: This material is not a very great fire hazard, but It will Burn at high temperatures and will decompose and emit chlorine.
Other Hazards: This material will affect the eyes, skin, and mucous membranes.
) Treatment and Handling: Wash eyes and skin with water and get patient to rresh air. Call a physician.
Storage and Handling: Store this material in a cool place away from fire hazards and strong oxidizing agents. This material can be stored in steel cars, tanks, or etc. Wear protective clothing, approved respirator, and chemical safe goggles when handling thlB material.
Shipping: Ship this material In containers marked with a red label.
UME Ca(0H)2
Toxicity: Lime Is not dangerously toxic, and it is regarded as more of a nuisance. This material Is a solid or slurry.
Fire Hazard: This material is not flammable.
Other Hazards: Lime 1b very hazardous to the eyes. It will burn the skin also, and the dust will affect the mucous membranes.
Treatment and Antidotes: Flood eyes and skin with large quantities of water. If lime is Ingested, get patient to vomit and call physician.
Storage and Handling: Lime can be stored in steel containers, anl people
should wear (protective clothing, respirators, and rubber or chemical safe
( goggles when handling lime.
t
Shipping: There are no special restrictions for shipping, but the containers should have a white label, a caustic warning.
HONS 0A7837
l Dept. 46 - Process Description
AHOCLOR
APPENDIX J
SAFETY AND TOXICITY DATA (Cont'd.)
ATTAPUIflUS EARTH
Toxicity: This earth Is not toxic In general.
Fire Hazard; There Is no fire hazard.
Other Hazards: Attapulgus earth can create a dust hazard similar to other dusts that contain silica.
Treatment and Antidotes: Consult a physician.
Storage and Handling; Attapulgus earth presents no speolal storage problem and should Be handling by persons wearing an approved respirator.
Shipping: There are no special restrictions on shipping.
HYDROaBN CHLORIDE (HC1)
Toxicity: This material is a gas under normal conditions and Is very
( Toxic. The M.A.C. Is 5-10 ppm and a concentration of 1500-2000 ppm would
be fatal to humans In a few minutes.
Fire Hazard; There Is no fire hazard under normal conditions, but wet gas reacts with some metals to form hazardous hydrogen.
Other Hazards: This material Is hazardous to teeth, skin, eyes, and mucous membranes.
Treatment and Antidotes: WaBh profusely with water. If Ingested, eat chalk, magnesium hydroxide, egg whites, and milk, and also administer
oxygen. Call a physician.
Storage and Handling: This material should be stored In a cool, well ventilated area away from oxidizing agents. This material can be stored In rubber lined, glass, or tantalum vessels. People handling this material should wear suitable clothing like rubber aprons, shoes, and gloveB. Also rubber goggles or chemical safe grades and approved pack or canister gas masks.
Shipping: Shipping containers must have a white warning label and a non-flammable label. Ship In appropriate containers Buoh as rail car
or carboy.
CHLORINE (CI2)
^ Toxicity: This material Is a gas under normal conditions and 1b very
toxio. The M.A.C. Is .35 to 2 ppm. A concentration of 1000 ppm would be rapidly fatal. Least concentration with detectable odor Is 3-5 ppm.
MGNS 047838
Dept, 2A6 - pfoceBS Description
AROCLOR APPENDIX J
SAFETY & TOXICITY DATA (Cont'd.)
CHLORINE (CI2) (Cont'd.)
Fire Hazard: There 1b no fire hazard under normal conditions, but there 1b an explosion hazard if chlorine is mixed with a strong reducing agent such as hydrogen or hydrocarbons on high temperature.
Other Hazards: This material causes eye, skin, and mucous membrane Trritation.
Treatment and Antidotes: The patient should be given oxygen immediately and treated for shock. Call,a physician.
Storage and Handling; This material should be stored in a ventilated
and cool plaoe away from fire hazards. When handling, wear a gas mask or approved respirator, clothing and rubber or chemical safe goggles. In strong chlorine concentrations, wear canister gas masks, Scott Air Pack, or oxygen breathing apparatus.
Shipping: The Bhipping containers must have a green gas label and a non-flammable label on. Ship In steel cars or cylinders.
MUNS 047839
Dept. 46 - Process Description
AROCI/OR
APPENDIX K
BACKGROUND INFORMATION
45.
The manufacture of Aroolore was developed quite by ohanoe. The Indian Refining Company, in the latter part of 1926, approached the Swann Chemical Company located in Anniston, Alabama, regarding the production of Biphenyl which the Indian Refining Company wanted to use as a heat transfer medium. The Swann Chemical Company agreed to produce Biphenyl, but first a process had to be/developed.
Two years later, in 1928, a pilot plant for producing Biphenyl became operative. However, in the meantime, the Indian Refining Company dropped all interest in Biphenyl. Since a process had been developed for manufacturing Biphenyl, the Swann Chemloal Company started looking for other outlets for this material. The simplest outlet was in the form of Chlorinated Biphenyls which were produced In the laboratory in 1929.
The Chlorinated Biphenyls produoed exhibited good electrical proper ties. This was reported to the General Electric Company who Immediately became interested In the product which ultimately developed into large scale consumption in electrical transformers and capaoitors.
The trade name "Aroolors" was adopted for the Chlorinated Biphenyl products. The properties of Aroclors vary from mobile oily liquids to fine white crystals and hard transparent resins. The excellent electrical properties, fire resistance and inertness of the Aroclors make them useful for many applications.
Plant equipment was installed to produce Aroclors at a rate of 3000 pounds per day or 1 million pounds per year. In the following years, this production rate was insufficient to meet the increases sales requirements.
The Swann Chemical Company was purchased by the Monsanto Company in 1935. This purchase gave Monsanto access to the patent rights for the production of Aroclors.
Production capacity needed to be expanded, and since Monsanto had a chlorine plant bb "Plant B" (now called the W. 0. Krummrieh Plant), the Aroclor production was transferred from the Anniston Plant to the Monsanto, Illinois Plant, where operations at an increased productive oapaoity started in September, 1936.
By 1940, the Krummrieh Plant production capacity was inadequate, and in 1941, a similar production unit was installed in the Anniston Plant.
MQNS 047840
Dept. 46 - Process Description
'
AROCLOR
APPENDIX L
TIME CYCLE
The design capacity of the department is 2,400,000 pounds per month or 88,800,000 pounds per year.
Figure 1 of this section illustrates the flow pattern of the Aroclor process and 11Bts the approximate time needed to complete each process step. The time table for the Aroclor process is summarized below:
Operation
Time (hours)
Equivalent pounds of Finished Product
Charge Chlorinator
Chlorination
1248 1248
1254
1260
Transfer to blow tanks
Aeration DlBti nation
1248 1248
1254
1260
Blending
Filtering
Dropping to Storage
.25 6.00 8.00 10.00 12.00
.25 2.00
1.75 1.75
1.75 1.75 2.00
2.00 2.00
6400 7200
8o4o
9100
The time required to make completed batches of the various Aroclors are tabulated below:
Aroolor
T2$2
1248 1254
1260
Batch Time (hrs.)
-------17725----18.25 20.25 21.25
Process operations including filter press cleaning, sampling, etc., are Independent of the batch completion time cycle because production time is not lost.
MONS 047841
Dept. 246 - Process Description
47.
AROCLOR APPENDIX M
QUALITY CONSIDERATIONS
The Aroclor compounds are among the most versatile chemically-made materials In Industry. Aroclors are useful In many ways because of their outstanding inertness.
Aroclors are used alone for particular physical Jobs such as insulating, heat transfer, sealants, and expansion media; and they
are used as components or extendors in elastomers, adhesives, paints, lacquerb, varnishes, pigments and waxes.
AroclorB must be highly pure, with dependably minimal traces of electrolytes for use in electrical applications. Electrical grade Aroclors must pass numerous stringent specifications. The following
tests determine Aroclor quality:
Hydrolysis Stability
Measure of chemically unstable chlorine compounds.
Munch or Monsanto Stability Test
Measure of thermally unstable chlorine compounds at elevated temperatures.
Thermal Chemical Chloride
Developed by the General Electric Company to measure chemically and thermally unstable chlorine compounds.
Resistivity
Measure of insulative properties.
Power Factor
Measures power loss due to current through a capacitor.
Dielectric Constant
Measures the capacitance of a Btandard such as air compared to
the capacitances of Aroclor.
Speoifio Oravity, Refractive Index
Measures of chlorination level.
The stability and electrical properties of electrical-grade Aroclors are paramount in quality considerations. The chlorination step of the process is most critical because many properties of the final product are determined by the properties of the crude Aroclor. Conditions In the ohlorlnator needed for a good quality product are:
1. Chlorination Temperature - The chlorination temperature must be greater than 120UC wlthin 30 minutes from the beginning of the ohlorlnation reaction to produce stable Aroclors. Results of research tests indicate that product stability Is better sb
the initial chlorination temperature is increased.
HONS 047842
Dept. g<l6 - Process Description
H8.
( APPENDIX M
QUALITY CONSIDERATIONS (Cont'd.)
2. Ferric Chloride Concentration - Research has found that the femo ohloride concentration must be at least 0.03^ to fomi stable products. Research recommends 0.05% ferric chloride. Lower catalyst ratios result in Increased "addition" chlorina tion as opposed to "substitution" chlorination, indicated by higher ohloride values and lower yields.
The isomeric distribution of the final product 1b a function of the type and concentration of the oatalyst used in the reaction.
Homogeneous suspension of the catalyst is extremely important. Good catalyst contact cannot be attained without homogeneous suspension. Since ferric chloride does not mix well with biphenyl, the dry catalyst must not be poured into the chlorinator.
3. Geometry of Reacting Vessel - The shape of the reactor affects the 'circulation and flow pattern of the reactants. It is suspected that the chlorine gas channels through a void space in the existing catalyst basket. This problem is presently
being studied.
The reactor must be designed such that circulation of reactants
is rapid and homogeneous and local over-chlorination does not ( occur.
4. Cleanliness - The ferric chloride settles to the bottom of the chlorinator. Areas of the packed bed become plugged with ferric chloride and channeling of reactant flow may result.
A steam clean-out of the ohlorinator may be an expedient mo the' to remove the ferric chloride. This method waB tried in th department, and evidently was successful. Further tests by the laboratory will verify the effectiveness of a steam clean
out.
5. Sparging - The sparger controls the gas distribution under the catalyst hold-up plate and the size of gas bubbles. It is riot
known whether the catalyst basket or sparger or both are the critical factors in achieving the proper flow of gas through the reactor. It is believed that the sparger should distribute
Bmall bubbles giving good gas distribution throughout the chlorinator. The small bubbles have a greater surface area per unit volume of gas for mass transfer and this should increase the reaction rate.
HONS 0 4 7 8 4 3
6. Raw Material Purity - The purity of raw materials can affect the quality of Aroclors. Sulfates are particularly harmful in the chlorine gas. It is suspected that sulfates poison the ferric chloride oatalyst and sulfates some of the biphenyl. If the ferric ohloride oatalyst is poisoned, the effective
catalyst concentration is reduced and thus unstable aroclors will be produced. The chemistry and mechanlBm of catalytic
poisoning are not known for certain. Sulfonated biphenyl is carried over during distillation and Ib not removed by earth treating.
Dept. 246 - ProcesB Description
AROCLOR
ATONDIX M
QUALITY CONSIDERATIONS (Cont'd.)
6. Raw Material Purity (Cont'd.)
Sulfonated biphenyl has ionic properties which lowers the resistivity of the finished product. A Brink MlBt Eliminator has been installed in Dept. 246 to eliminate the chlorine impurities.
7. Earth Treatment - The factors affecting stability also in fluence the electrical properties of Aroclors. An absorbent will be ineffective if the Aroclor waB not prepared in a manner such that a stable product was formed during the chlorination reaction.
However, research has found that absorbents are very effective for improvement of electrical properties by removing ferric chloride and tars carried over during distillation, provided the crude Aroclor has good stability.
The absorbent used in Dept. 246 (after distillation) is Attapulgus Earth, the concentration should be 0.5# for Aroclor 1242 and 0.1# for other Aroclors. The earth muBt be heat treated at 250C for a minimum of 4 hours before addition to the Aroclor. Heat treatment reduces the moisture and activates the earth.
8. Lime Treatment - It is important that proper amount of lime (250 founds per still run) be added to the still to prevent sublimation of ferric chloride.
9. The blend tanks, finished product tanks, and Aroclor 1242 and 1254 Btorage tanks are blanketed with nitrogen gas. Nitrogen blanketing maintains the electrical properties of the Aroclors by preventing corrosion of the equipment.
In summary, the chlorination step of the process is the most critical. A good quality Aroclor cannot be produced if a stabl compound is not formed during chlorination.
Once a Btable compound is formed, other techniques such as use of lime, absorbents, and nitrogen blanketing are used to maintain and Improve electrical properties.
MONS 047844
50.
Dept, 246 - FroceBs Description
AHOCIOR APPENDIX M
QUALITY CONSIDERATIONS (Cont'd)
Absorbents - Numerous absorbents have been screened in the laboratory at various contact temperatures for their effect on resistivity of plant untreated Aroclor 1242.
The most satisfactory absorbent pound for improving the resistivity of Aroclor 1242 was LVM attasorb. Table I of this section liBts the laboratory results of the different absorbents used to treat
Aroclor 1242.
Degradation of Aroclors
Degradation of Aroclors, which leads to loss in electrical resist ivity, is one of the short comings of using Aroclor as a dielectric expeclally Bince only a very minor degradation can cause a serious breakdown in electrical equipment.
The thermal degradation of fractionated Aroclor has been measured at 250C and the amount of Hydrogen Chloride liberated was measured The results of these teBts are listed in table II of this section.
Aroclor 1242 has been degraded by ultravlolent light, and the decrease in electrical resistivity with irradiation time was measured. The plot of resistivity versus concentration is a curve for a weak electrolyte. It is possible to remove the conducting material brought about by photo-degradation, and restore the resistivity of its original value by passing the degraded material over activated alumina.
Thermal degradation of Aroclors is minor compared to photo chemical degradation. Thermal treatment causes release of a small amount of hydrogen chloride initially, but this evolution ceases after a short time. Such behavior 1b attributed to thermal degradation of Impurities. If Aroclor is irradiated, then exposed to a thermal treatment, appreciably more HC1 is liberated.
HONS 047845
Dept, gil6 - Process Description
AKOCLOR
APPENDIX M
QUALITY CONSIDERATIONS (Cont'd.)
51.
TABLE I
ADSORBENT SCREENINQ DATA
Adsorbent
Adsorbent Pretreatment
Contact Temperature C
LVM Attapulgus Earth
LVM Attapulgus Earth
IMV Attapulgus Earth
LVM Attapulgus Earth
AttaBorb - LVM
None
Heated at 250C 12 Hours
Heated at 350C 12 hours
Heated at 350C 4 hours
None
Attaclay
None
Activated Alumina (Alcoa Orade P-3 -325 mesh)
None
Voclay 325 (Western Bentonite) Panther Creek (Southern Bentonite) Plltrol Qrade 1 Zeolex 7 (Zeolite) Florlte 60 mesh (Activated Bauxite) Suprex L-Q (Kaolin) Attasorb - LVM
Attasorb - RVM
None
None
None None None None Heated 35 CPC 12 hours None
60 80 100 120 60 80 100 120 60 80 100 120 60 80 100 120 60 80 100 120 80 100 120 60 80 100 120 80 100 120 80 100 120 80 80
100
100
100
100
.
Volume Resistivity at 100
ohm-cm. x 10C
3400 2000 2800 2900 4200 6400 7200 6100 9300 9000 6300 6300 2400 5600 6000 5700 9700 12,100 13,700 17,800 10,200 5400 6000 2100 2500 2800 3100 5700 3800 9700 6200 11,300 8100 2600 7000
3600
4500
12,200
16,200
HONS 0 4 7 8 4 6
( Dept, 246 - process Description
52.
AROCLQR
APPENDIX M
QUALITY CONSIDERATIONS (Cont'd.)
AdBorbent
TABLE I (Cont'd.)
Adsorbent Pretreatment
Contact Temperature C
Volume Resistivity at 100'
ohm-cm. x :
Linde Molecular Sieve Type 4-A
None
6o 2100
Laminar Alumina
None
60 900
(
Note: Reslsvitlty of Aroclor before treatment 1 x 10^ ohm-om.
(
MONS
Dept. 24G - Process Description
AROCLOR
APPENDIX M
QUALITY CONSIDERATIONS (Cont
TABLE 11
THERMAL DEGRADATION OF AROCLORS AT 250C
Aroclor 1221 1232 1242 1248 1254
Bra. of HCl/sm x 106
3.35 6.73 11.07
3-?l 6.42 9.81
5.96 9.58 13.00
3.61 5.44 8.48
3.43 3.96 6.43
Heatlrw Time
1 hr. 2 hrs. 5 Krs.
1 hr. 2 hrs. 5 hrB.
1 hr. 2 hrB. 5 hrs.
1 hr. 2 hrs. 5 hrs.
1 hr. 2 hrs. 5 hrs.
53
( HONS 0*7840
Dejg^^S^^^PrpceBsJDesorlgtlon
AROCIiOR APPENDIX N
MISCELLANEOUS REFERENCES 1. St. Louis Report No. 2694, Job No. 171-1028, February 15, 1952.
Title: Operation of Aroojor Stills At Increased Pressure For Increased RatcB
Summary: Distillation runs were made at 20 to 30 mm Hg. The rate of distillation of 1200 series Aroelors Increases with pressure,
2. St. Louis Report No. 2755, Job No. 2-02-760.01 - 3948-3 March 6, 1961.
Title: Improved Aroclor 1242 Studies
Summary:
Studies were carried out to determine the effect of temperature, chlorine content, and catalyst concen tration In chlorinated biphenyl mixtures. 2,4-dichloroblphenyl Is the peroursor of the high dielectric constant, trlchlorinated components.
3. St. Louis Report No. 2072, Job No. 2-02-750.01-3428, May 4, 1958.
Title: Final Report on Aroclor Process Studies.
Summary:
Purity of raw materials, catalyst concentration, reaction temperature and rate of chlorination were
the variables studies with respect to their Influence on the stability of the finished product.
4. St. Louis Report No. 2540, Job No. 171-616, December 28, 1958.
Title: The Effect of Prolonged Heat on the Electrical Properties of Aroolors.
Summary: AroclorB 1232, 1242, 1248 and 1254 were held at 130C. The power factor was periodically measured.
5. St. Louis Report No. 2234, Job No. 171-451, June 14, 1956.
Title: Evaporation Loss of Aroelors.
Summary: The evaporation Iobs of Aroelors was determined at 100C under static conditions.
MONS 047849
Dept. 246 - Process Description
AROCLOR ~ APPENDIX N
MISCELLANEOUS (Cont1d.)
REFERENCES (Cont'd.)
I
/ / /
/
/
55.
, '
6. St. Louis Report No. 2790, Job No. 171-1028, July 3, 1952.
Title: Increased Producti:n of Aroclors by More Rapid Rate of Chlorination.
Summary: Chlorination rate was increased from 400 pounds per hour to 770 pounds per hour. Aroclors produced at increased rate was within specifications.
7. St. Louis Report No. 1842, Job No. 2-02-750.01-3368 July 12, 1957.
Title: Use of Ferric Chloride as Catalyst for Production of Aroclor 1242.
Summary: The comparison of stability chloride valueB revealed no difference between the product made with iron turnings as catalyst and ferric chloride as catalyst.
8. St. Louis Report No. 2096, Job No. 2-02-750.01-3202, June 6,
1958.
Title: Resislstivlty Improvement of Aroclor 1242,
Summary:
Numerous absorbents were screened at various contact temperatures for their effect on resistivity of plant untreated Aroclor 1242. Heat activation of AttapulguB Earth was also studied.
9. E. E. Martin, OPERATING INSTRUCTIONS FOR DEPT. 246.
W. Q. Krummrlch Plant, I96TT"
`
10. E. E. Martin, PROCESS DESCRIPTION FOR MANUFACTURE
of aroclors. 155?;;
^
11. E. Mather, PROCESS DESCRIPTION FOR MANUFACTURE OF AROCLORS. 15W.
MONS 047050
Dept, 246 - Process Description
AROCLOR
APPENDIX N
MISCELLANEOUS
The following table shows the results of tests which measured the evaporation losses of the various Aroclors.
Aroclor
Evaporation Rate gms/om2/hr./100C
Aroclor 1221
.00174
Aroclor 1232
.000874
Aroclor 1242
.000338
Aroolor 1248
.000152
Aroclor 1254
.000053
Aroclor 1260
.0000088
Aroclor 1262
.0000132
Prom the above results, the evaporation rate for Aroclor 1262 is greater than that of Aroclor 1260. This unexpected result may be explained by some difference in the conditions of which the two lots were prepared.
The reaction products in Biphenyl Chlorination differ with the type of oatalyst used. Results of research investigations are listed belows
Catalyst
Pe C3o 3b Clo Ti CI5 Sn Clj|
Isomer Distribution of Aroclor 1232
2-
'i'i' * 2,4 - gll.'. - '4,4'
15* 11
11 24
7#
0.7 0 1
15* 20
20 16
6* 3.6 2.2
2.3
3856
38 46
38
11# 18
14
18
trX
9% 9 7 1.3
HONS 047851
57.
Dopt. 246 - Process Description
AROCLOR
APPENDIX N
MISCELLANEOUS (Cont'd.)
Some of the typical operating difficulties in department 246 and possible remedies are given below:
CHLORINATORS
Trouble
Cause
Remedy
Chlorlnators operating against too much back pressure
Plugged off-gas lines
Open lines and steam them out. Dry out lines with air before resuming operation.
Chlorinator slow in
1. Low chlorine
1. Call chlorine
picking up gravity
pressure or low
dept, for more
chlorine gas
gas
concentration
2. Check biphenyl
2. Wet biphenyl
storage tanks for
l moisture.
BLOW TANKS
Blow tanks stacking off
Operating chlorlnators with vent open
Close chlorinator vent; possibly re duce air to blow
tanks
STILLS
Not enough vacuum
1. Ejectors not pull ing properly
2. Coke scrubber contains water
1. Check ejectors
2. Drain coke sorubber
36" SPARKLER FILTER
Foreign material in filtrate samples
Dirty filter or broken paper
Clean and re-paper press
(~
HONS 047852