Document EmjkVLo9gRZmOB9rBbvXnDZM0
AROCLOR* DIELECTRIC FLUIDS FOR CAPACITORS
Trademark of Monsanto Company
kqns 073260
/
CONTENTS
Introduction The Advantages of Aroclor* Dielectric Fluids
Properties
Composition physical Properties
Viscosity Vapor Pressure Chemical Properties Electrical Properties Permittivity Loss Tangent D.C. Resistivity
Construction
Paper Assembly of Capacitors
\
Production Earth Treatment Impregnation
Performance A.C. Capacitors D.C. Capacitors
Toxicity and Handling Precautions
Appendix A Laboratory Measurements on Aroclor Fluids
Appendix B
'
Compatibility Testing Method
Pg
Trademark of Monsanto Company
n
NGNS 073201
INTRODUCTION
The Aroclor* dielectric fluids are a range of chlorinated biphenyls produced by Monsanto for the manufacture of liquid filled capacitors. These products are generlcally known as aakarels', synthetic -fire resistant insulating liquids which, if decomposed by an electric arc, evolve only non-explosive gaseous mixtures.
The Aroclor liquids were first used in the United States in 1931 and today they are extensively used in the capacitor industry throughout the world.
There are three grades of Aroclor fluids in common use for capacitors as indicated below:
Aroclor 1242 (Commercially known as Trlchlorobiphenyl) the most economically attractive, is essential for outdoor capacitors in a low temperature environment, but is more difficult to handle In production.
Aroclor 1248 (Commercially known as Tetrachloroblphenyl) is a
compromise between the economic advantages of 1242 and the ease
of handling of 1254.
.
Aroclor 1254 (Commercially known as Pentachloroblphenyl) is the V
easiest to handle in production but does not gain the maximum' I
economic advantage.
Trademark of Monsanto Company
3
MO*S
Advantages of Using Aroclor Fluids.
Reduoed size capacitors are possible for a given rating;
fluorescent lighting units are a particular application in which
this is utilized.
'
-
Reduced raw material cost arising from the smaller quantity of paper and foil needed in manufacture.
Reduced labor content because of the fewer windings required. Increased through-put from a given plant capacity with existing labor foroe.
Higher Btress operation' of capacitors is possible because of a
Bore uniform permittivity (Dielectric Constant) in the
eapaoitor. '
.
Longer life capacitors are produced because of the high stability and resistance to oxidation of Aroclor fluid.
Small fire hazard because Aroclor fluid is fire-resistant.
r
MONS 073263
PROPERTIES Values for the aiost important properties
0
H*
ftr
\jp Aroclor dielectrics ere given in the Table.
Tvoical Properties of the Aroclor Dielectrics. (These values do not constitute a specification)
Property
Aroclor 1242
Aroclor 1248
Vise, at 37. BC. (ASTM D88-56) Vise, at 54.4C. (ASTM D88) Vise, at 98.9C. (ASTM D88-S6)
Sp. Gr. at 25/15.5C. (ASTM D1810) Sp. Gr. at 65/15.5C. (ASTM D287) Sp. Gr. at 65/15.5C. (ASTM D1810) Color, APliA Condition Acidity, mg. KOH/g. (ASTM 0974,0664) Pour Point, C. (ASTM 097-57)
Refractive Index at 25C. (ASTM D1807) Refractive Index at 20C. Inorganic Chlorides (ASTM D1821) Distillation Range (ASTM D-20) Distillation Range (ASTM D-20-56)
C. Corrected for stem and
X o X tn
barometric pressure Water Concent (ASTM D1533-60) ResistiviCy, 100C., 500 v. D.C.
at 0.1" gap. (ASTM 01169) Dielectric Constant, 100C.
o
NJ o>
at 1000 cycles (ASTM D924-49) DieLectric Strength (ASJM D877-49)
at 25C. KV min.* Flash Point, Cleve open cup (ASTM D92-57)* Flash Point, (C.O.C.)* Burn Point (ASTM D92) Fire Point* Sulfates (ASTM D117-31)* Fixed Chlorine Content (Carius)* Evaporation at 100C* for 6 hrs.* Specific Heat at 25C. * Hydroly/able Chlorine Compounds
(ASr:i ul820-61) ppm. chlorides max. Thermal Stability (ASTM D1936) chlorides Coefficient of Thermal Expansion * (ASTM 01903)
82*92 sec.Saybolt Univ, 1.381 - 1.392
50 max.
'
Clear
0.01 max.
-14 or lower
1.6240 - 1.6260
0.05 ppm. max.
10% 325 min. 902 360 max. 35 ppm. max
500x10^ ohm-cm.,min-
4.7 to 4.9
35 170 to 200 C.
Hone to boiling point Hone 43 + 0.5% 0.42 max. 0.29
0.5 0.4 ppm. max. 0.00068 cc./cc./C.
73*80 sec.Saybolt Univ.
1.404 - 1.414
100 max. Clear 0.01 max. -7
.
1.630 - 1.631
343 - 373C.
35 ppm. max 500x10^ ohm-cm.,min.
4.6 35 193C.
475 - 48.5% 0.27
* Hoc determined unless by special request.
Aroclor 1254
44-48 sec.Saybolt Univ.
1.495 - 1.505 50 max. Clear 0.01 max. 7-12 1.6370 - 1.6390
0.05 ppm. max.
10% 366 - 378C. 50% 371 - 383C. 90% 378 - 394C. 35 ppm. max.
500x10^ ohm-cm., min.
4.15 to 4.35
35
Higher than 350 C.
None 55 + 0.5% 0.42 max. 0.26
1.0 0.5 ppm. max. 0.00066 cc./cc-/C.
NOTE: Tm uompani properties obtained by different laboratories, exactly the same test methods and techniques must b>. ibcd Different test methods or techniques will produce varying results-
(ft) Tr.-idi mark of Monsanto Company
Composition Aroclor fluid Is made by the chlorination of biphenyl to predeter mined chlorine contents which are Indicated as a percentage by the last two digits In Jthe code number e.g. Aroclor 1248 contains 48jS chlorine by weight. Each grade of Aroclor fluid contains a range Of chlorobiphenyls with differing numbers of hydrogen atoms sub stituted by chlorine, and In each of these chlorobiphenyls there Is abundant isomerism.
Physical Properties Viscosity. The Viscosity-temperature characteristics of the Aroclor liquids are shown In Figure 1. It can be seen that Aroclor 125^ is the most viscous at all temperatures and Aroclor 1242 the least. The differences between the three grades are greatest at lower temperature and beoome less as the temperature Is raised. a4 previously explained, Aroclor fluid consists of a number of homologues and consequently each grade does not have a sharply defined melting point, but remains liquid over a wide temperature range. Instead, their vlscosltes Increase smoothly but sharply AS the temperature Is reduced. Aroclor 1242 has the lowest pour point of all three grades.
Vapor Pressure. It can be seen that Aroclor 1242 has the greatest vapor pressure at a given temperature and Aroclor 1254 the least. This fact should be considered in determining the fluid tempera ture during degasification and impregnation. The vapor pressure varies with absolute temperature according to the usual logarith mic law. The variation of the vapor pressures of the Aroclor*
* GNS 073265 (f
dielectrics with temperature Is shorn in Figure 2.
Chemical Properties
The chemical inertnfess of Aroclor fluid i3 outstanding. The liquids are not oxidized by exposure to air or oxygen even under extreme conditions of temperature and pressure, nor do they react with moisture. When subjected to a bomb test at 140C in oxygen at a pressure of 250 p.s.l.g. (17 kg/cm^), there was no evidence
of oxidation as Judged by development of acidity or formation of
sludge. They can withstand many years of service in electrical equipment at high temperatures without oxidation.
Aroclor fluid is manufactured to a rigid specification ensuring a low value for free acidity and free chlorides. Tests have shown that these low values are maintained even when the liquids are heated for prolonged periods in the presence of air and moisture at elevated temperatures.
Aroclor fluid is slightly sensitive to ultra-violet light, which can result in the formation of traces of ionic contaminants.
Aroclor fluid undergoes no decomposition at temperatures up to
175C. At much higher temperatures, or when subjected to arcp,
the principal decomposition products are carbon and hydrogen
chloride.
',
Laboratory tests and practical experience have shown that phosgene. Chlorine, or hydrocarbons are not formed as decomposition products of Aroclor fluid.
MOMS 073266
7
Electrical Properties The laboratory methods used to measure the electrical properties of the Aroclor dielectrics are described in Appendix A.
Permittivity (Dielectric 'constant') The permittivity of Aroclor fluid is higher than that of mineral oil, which accounts for the size reduction and increase in stress that is possible. Stresses of 15 to 17 V/um are common; and higher values are reported.
Since chlorinated biphenyls are polar compounds, their permittivi ties are temperature-dependent. This Is Illustrated in Figure 4, which shows the variation with temperature of the permittivity of each of the three grades of Aroclor fluid. These readings were taken at a frequency of 50 c/s and an electric stress of lV/ura.
ki the lowest temperatures, all three grades have a permittivity
of about 2.8, since, because of the very high viscosity, there is
no contribution from dipole orientation polarizability. As the
temperature is increased, the permittivity begins to increase when
the viscosity becomes sufficiently reduced to allow the molecular
dipoles to orientate themselves in the alternating electric field.
The temperature at which this increase in permittivity begins is
dependent upon both the grade of Aroclor fluid (being lowest for
Aroclor 1242), and the frequency of the applied field.
r
As the temperature is further increased, the permittivity passes through a maximum, and then decreases. This decrease in permit tivity with increase of temperature is due mainly to the disturbance
MCNS 073263
of the alignment of the dipoles by thermal agitation. The maxi mum permittivities attained vary with the grade of Aroclor fluid, being greatest for Aroclor 1242 and least for Aroclor 1254. with Aroclor 1242 the permittivity of this series reaches a maximum, and a further reduction In chlorine content causes a reduction In permittivity, as shown In Figure 3-
Loss Tangent. The loss tangent, or power factor, of Aroclor fluid Is highly temperature dependent. This Is Illustrated In Figure 5, which shows how the loss tangent (plotted here on a logarithmic scale) of each of the three grades vary with temperature.
The curve for each grade consists of a peak due to absorption associated with the transition In permittivity, followed by a region where.the loss tangent steadily increases with temperature. In this latter region, the loss tangent follows the increase in fluidity with Increasing temperature and is highly dependent upon the purity of the fluid. The temperature at which the peak occurs Is about 19 below the pour point.
P. C. Resistivity. The values quoted In the table are typical for Aroclor fluid as produced; but they can be Improved by vacuum de hydration or treatment with suitable grades of absorbent such as fuller's earth or activated alumina. Values of 20 to 50 T/V cm at 100C are common. The values for Aroclor 1242 and 1248 ar^e lower than 1254 because a given amount of contamination reduces the d.c. resistivity more with a liquid of lower viscosity and higher permittivity.
MOWS 073268
fche approximate variation of the atc. resistivity of the 3 trades of Arocior fluid with temperature is shown in Figure 6.
I
MOWS 073269
to
M.
K M tM M IC VISCOSITY <cS)
MOMS 0 7 3 2 7 0
Figure 1 The viscosity-temperature characteristics of the Aroctor dielectrics Trademark of Monsanto Company
MGNS 073271
r2-
*
Fljure 2 The variation of the vapour pressure of the Aroclor dielectrics with temperature Trademark of Monsanto Company
' . ' . >3
-figure S The variation of permittivity with chlorine content
nohS 073*u
?
Figure 4 The approximate variation of permittivity of Aroclor* fluids with temperature Trademark of Monsanto Company
HONS 0 7 3 2 7 3
HOhS 01321k
TfNPfIMTVIl (*()
near* 5 The approximate variation of the dielectric loaa angle of Aroclor* fluids with temperature
( r il iiu u iin i iM titi
MCNS 073275
//
Figure 6 The approximate variation of the DC resistivity of the
Aroelor* dielectrics with temperature
T'rnrlomrk oiiffa..M- ,,on sa---n--t--o------Cma, ndnnyv
............ ....................
7
(it oky rtnt oEMiTr
-i 10
MOMS 073276
D
Flturo 7 The permittivity of paper impregnated with Aroclor* fluids Trademark of Monsanto Company
CONSTRUCTION
Construction of Aroclor Fluid Capacitors Paper Kraft paper Is used because of Its purity and Its nearly five fold capability of acid neutralization over rag tissue.
.
The permittivity of Impregnated paper depends upon the density of the paper as well as the permittivity of the lmpregnant. This relationship is shown in Figure 7 for the 3 grades of Aroclor fluid and for mineral oil, the values being calculated at a temperature of 20C. Since paper Impregnated with Aroclor 1242 has the highest permittivity, the least area of windings is needed to obtain a given value of capacitance and the greatest economy la obtained.
Low density paper has been shown both theoretically and practical ly to give the least dielectric loss in a capacitor. This effect arises from the distribution of electrical stress between the cellulose fibres and the lmpregnant and is in addition to, and independent of, any losses in the lmpregnant itself.
Most manufacturers of capacitor tissue are familiar with Aroclor fluids and have developed suitable grades for use with them.
f Assembly of Capacitors It cannot be emphasized too strongly that every material that comes into contact with Aroclor fluid must be carefully checked for compatibility. Aroclor is a good solvent for many thermo-
HONS 07327?
plastics and elastomers and the resulting solution has a high dielectric loss tangent. Materials which must be considered Include the major insulation, the lead-through insulators, any neans of sealing the container and the residues from the manu facturing process e.g.. fluxes left after soldering. Connection tags if of copper should be tinned, otherwise stainless steel can be used. Soldering should be kept to a minimum and where possible the special cored solders which have been developed by manufacturers for use with Aroclor fluid should be employed. Opaque bushings must be used because of the slight light sensi tivity of some grades of Aroclor fluid, particularly Aroclor 1242.
HONS 073^78
>9
PRODUCTION
Production of Capacitors Although the production of Arocl'or fluid Impregnated capacitors is generally similar to that of-oil Impregnated units, and similar plant may be used, there are several differences In detail and these are described In the following sections.
If an oil plant is to be changed to Arocl'or -fluid, resistant gasket seals must be Installed and the equipment thoroughly clean ed and flushed with Aroclor fluid (which is subsequently discarded).
Purification (Absorbent Treatment)
.
The main difference between a chlorinated biphenyl and an oil
capacitor impregnation plant is the purification section. It should
have the capability of degassing and treating the fluid with
absorbent material to remove contamination, if capacitors are
filled by a flooding technique, then Aroclor fluid which is unused
and returned to the system will be found to be slightly contaminated.
This fluid must be purified by treatment with a suitable absorbent
auch as fuller's earth or activated alumina. For this to be fully
appreciated, it must be realized that the Aroclor liquids are more
susceptible to contamination than their mineral oil counterpart.
Because of their higher solvent action and higher permittivity,
the contamination level which would be acceptable in mineral oil
and which is commonly encountered in an impregnation plant will be
unacceptable for Aroclor fluid.' The absorbent treatment can be
carried out in two principal ways. In the first place the absorbent
MGNS 073279
Is contained In a column and the liquid la circulated until the contamination Is removed. Alternatively, activated absorbent la added to the liquid in a container and It is stirred to ensure Intimate mixing and then the earth la filtered through oven dried paper filter. In both cases either fuller's earth or alumina may be used and each must be activated. It has been found by experience in laboratory tests that the earth may be over activated and the optimum temperature is about 2Q0C'. for 6 hours. If this is then added In quantities to the material to be treated, it is ensured that the fresh activated earth is used each time and the treatment stay be more easily controlled in this way in the mixing technique. However, there still exists the problem of separating the absorbent and here the column technique has a considerable advantage, since circulation through the column does not necessitate further filtra tion. This method has the disadvantage that the column gradually becomes less active during Its life and there is not always the same degree of control over the treatment process.
Impregnation It is customary to store the capacitor liquid in a large tank the size of which depends on whether the material is delivered in drums or tankers. It is recommended that these storage tanks be lagged and heated since at low temperatures difficulty would be
encountered in pumping the Aroclor 1254 and in certain extremes of temperature even Aroclor 1242 can become umpumpable. After transfer from the storage tank the liquid is first earth treated and mixed with any unused liquid drawn back from the capacitor
MOHS 073280
impregnation tank, if applicable. The treated liquid is then subjected to vacuum drying and de-gassing in exactly the same way as with mineral oil and after this process it 1b passed to the final storage vessel where it is held before being passed to the impregnation section. Large capacitors may be vacuum impregnated by a manifold technique in which the liquid is piped individually to each capacitor can. Alternatively, they may be filled by a flooding technique which is more applicable to the smaller fluorescent lighting capacitors. Here the capacitors can be loaded in wire cages and completely immersed in the liquid in the same way as with mineral oil. For the actual impregnation cycle the following temperaturea are recommended:
Aroclor 1242 Aroclor 1248/1254
70- 6oc 90-100c
.
The lower Impregnation temperatures are recommended for Aroclor 1242 since it will be sufficiently thin at these temperatures.
After the impregnation cycle has been completed the vessel should
be cooled to below 50C before being opened. This is to avoid
the unpleasant fumes of Aroclor vapor escaping into the work-shop.
The capacitors should then be sealed as quickly as possible at
the proper temperature and degreased before final painting and
testing.
'
Toxicity precautions and the handling of Aroclor fluids is dealt with in a separate section but workers handling the liquid, or
a*'
MGNS 073281
capacitors coated with It, are advised to wear gloves or use barrier cream.
43
MGNS 073282
PERFORMANCE
A.C. capacitors at low ambient temperatures.
If a capaoitor is continuously energized before and whilst
.
subjected to a low temperature environment it operates satisfac
torily because the heat produced in the dielectric balances the
heat lost from the case. A self-compensating process exists such
that if the temperature of the dielectric falls the losses in
crease, and more heat is generated to establish a new equilibrium.
Tests have shown that a capacitor impregnated with Aroclor 123; can operate continuously energized in ambient temperatures down
to -60pC#
emrvived-whilsb--installed "outdoor3durlng'>the~vint er~1962-3v
If, however, a oapacitor is subjected to a low temperature
environment first and then energized it may be damaged by dis
charges occurring in voids formed by the contraction of the
dielectric before it has time to heat up sufficiently. Cases when
this might occur are in street lighting capacitors during winter,
or capacitors installed in a plant that has been shut down during!
winter holiday periods. For this reason, the following minimum
ambient temperatures are suggested for the J grades:
Aroclor 1251*. - 7C
_
f
- Aroclor 121*8 -28C
Aroclor 121*2 -1*5C
'
.
MONS 073283
P.Cfl Capacitors Aroqlor fluid is also used in d.c. capacitors but it has been found that at the high stresses used the service life of the capacitor tends to be reduced if the working temperature is raised above 40C. This can be overcome by using stabilizers In the Aroclor fluid to overcome the slight electrochemical degradation which tends to take place. Generally the effect is proportional:to the quantity of stabilizer used and up to 1 per cerit of .anthraqulnone or 2-ethyl anthraquinone and 2 per cent of .azobenzene have been used.
t
MOWS 07328**
TOXICITY
'
Toxicity and Handling Precautions
'
Aroclor fluid made by Monsanto has been used for over 35 years
without causing any toxic effects, but it must be handled with
care.
Tfiese precautions should be observed: li,. Avoid skin contact. Protect the hands, preferably by
oil-resistant gloves.
5>. If skin contact should occur, wash off with soap and water.
3* If hot Aroclor fluid must be handled In a closed or confined area provide exhaust ventilation or wear an approved respirator.
If Aroclor fluid gets In the eyes, flush with large amounts of.water. In the event that irritation persists refer the lA^lent to a Physician.
J, Infrequent exposure to Aroclor vapor will not cause any 111
effect, but prolonged exposure to a high vapor concentration
should be avoided.
'
Jf these precautions are neglected acne may develop and , excessive exposure may cause liver damage.
MCNS 073285
APPENDIX A
Laboratory Measurements of Aroclor Fluids Monsanto's test methods are based on the ASTM Standards and procedures. However, for electrical testing many techniques stay be used. Therefore, understanding and Interpretation may be required to correlate different results obtained under various testing conditions.
Monsanto will work with you In comparing the various techniques for measuring electrical properties.
Process Control Measurements In operating an Impregnation plant, It Is convenient to be able to measure the electrical properties of the Aroclor fluid without the necessity of taking samples. A cell Installed In a flow line la useful for this purpose. It should be arranged that there Is a turbulent flow of Aroclor fluid through the gap between the electrodes except when a measurement Is being taken so that adequate cleaning of the electrode surfaces occurs. To obtain the same value of d.c. resistivity with a plant cell and with a laboratory cell It Is necessary for the Aroclor fluid to be (!) stationary whilst the measurement Is made, (2) subjected to the electric field for one minute, and (3) at the same temperature>.
HOWS 073286
APPENDIX B
Compatibility Testing Method Procedure If the material Is available In a laminar form or is a surface coating a piece 25 mm square Is cut from a sheet. Other materials are selected so that the sample taken Is present at the same con centration as In the finished article. The sample Is put Into a glass Jar that has previously been cleaned and dried In the follow ing sequence: 1. Wash In benzene 2. Wash with hot water and detergent 3. Six rinses with distilled water 4. Rinse twice with analytical grade acetone 5. Dry In an oven at 130C for 1 hour To this Jar, and to a similar one without a specimen within It, are added 150 ml of Aroclor fluid. The Jars are then closed with ground glass lids and aged In an oven at 100C for 7 days.
After ageing, the Jars are removed from the oven and the electrical properties of the Aroclor fluid In both the specimen Jar and the eontrol Jar are measured at 100C according to the method described
In Appendix A, The specimens are examined for swelling or other
signs of deterioration, and any color change of the Aroclor fluid
Is noted.
>
Results
The Aroclor fluid In which the sample has been Immersed must not experience a decrease In resistivity below 1 terohm-cm at 100C.
Information on materials which have been tested is available on
request.
A
MCNS 073287
Technical Service The technical service staff of Monsanto is always ready to provide additional information on the use of the materials described in this report, and to assist manufacturers in the eolutlon of particular problems ensuing from their application.
Nothing contained herein is to be construed as a recommendation to use any product in conflict with any patent. MONSANTO MAKES NO WARRANTIES AS TO THE FITNESS OR MERCHANTABILITY OF ANY PRODUCTS REFERRED TO, no guarantee of satisfactory results from reliance upon contained information or recommendations, and disclaims all liability for any resulting loss or damage.
MOHS 073288