Document Em6JY1my2y3nVYN4bJQJZzbdL
Air
System
Equipment
Fans and Ventilating Equipment
Ghe
NEW YORK'll
BLOWER
COMPANY Jl
GENERAL OFFICES 32nd STREET * SHIELDS AVENUE CHICAGO
fACIORIES i LAPOME. I N 0 . d CHICAGO. ILL.
Experienced Air Engineers
Representatives in Principal Cities
(Products . . for all indus
trial processes, ventilation andNheating. Specify them for every industrial, com mercial and institutional requirement. Check these nine classifications which give thumb nail specifications:
CENTRIFUGAL FANS AND BLOWERS Type ME Housed Centrifugal Wheels--Quiet Operating, Slow Speed Type and/or High Speed Wheels with Non-overloading Horse power Characteristics. Range of Standard Wheel Sizes 15 in. to 80 in. Wheel Diameter. Sizes 15 inch to 80 inch Wheel Diameter.
JUNIOR CENTRIFUGAL BLOWERS Type ME Junior Fans, direct connected Motor Driven. Range of Sizes 6 inch to 12 inch Wheel Diameter.
DISC TYPE (or PROPELLER) PANEL FANS Comet EXHAUSTAIR Ventilating Fans, Automatic Shutters, Power Roof Ventilators, direct connected Motor Driven. Size 10 inch to 30 inch Wheel Diameter. Heavy Duty Type, Pulley Driven, GIANT Disc Type Fans, Regular Sizes 36 inch to 108 inch Wheel Diameter with Round Body Frames.
INDUSTRIAL UNIT HEATERS Disc or Propeller Fan, Ceiling Suspension Type, NYBCo COMET Unit Heaters with Molybdenum Alloy Corrosion-Proof and Freeze-Proof, Extra Heavy Welded, Longlife Ferrous Heating Element. Suitable for low or high-pressure (unlimited) Steam Pressures. Capacities 24,000 to 300,000 BTLTs per Hour. Excel AIR-FLOW Centrifugal' Type Factory Unit Heaters. Blower-Type Unit Heaters with Encased Centrifugal Fans with NYBCo Molyb denum Alloy Welded Steel Heating Element (either Blow-through or Draw-through Type). Floor Type, Side-wall or Ceiling Suspension. Capacities 169,000 to 1,000.000 BTLTs per Hour.
AIR WASHERS A completely engineered line of PEERLESS Air Washers, Air Cleansing, Air-Conditioning and Cooling. Complete with Single- and Double-bank Atomizing Spray Systems, Marine Type Doors, Eliminators, Entering and Backspray Louvres, Water Strainers, Pumps and Motors, and with or without Humidity Flood ing Provisions. Sizes and Capacities ranging from 3,600 CFM to 76.000 CFM.
HOT BLAST HEATING SURFACE NYBCo "STEELFIN" Longlife High Preosure Molybdenum Alloy Steel, All Welded, Extra Heavy Duty. Homogeneous Fin-andOval-Tube Hot-Blast Heating Surface. Hotdip Overall Metallic Coating, Including Head ers. A Super-quality Product--proof against faults common to Surfaces constructed of Nonferrous and Cast Iron Materials. An Engi neered Product of Sizes and Capacities for Steam Pressures (or Hot Water Equivalents) from 2 lbs. to 150 lbs. duty. High Temperature
or Low Temperature Fin Spadngs, and a Range of Air Velocities from 400 to 1000 Ft. per Min.
VENTO, AEROFIN, and OTHER HEATING AND COOLING SURFACES
The various types and makes of Heat Transfer or Heat Exchange Surface, as regularly sold through the outlets-of~manufacturers of Fansystem Apparatus. These types of Surface are offered in various combinations and sizes, together with full and complete engineering recommendations.
MISCELLANEOUS Dust and Shavings Exhausters and Material Conveyor Blowers (Centrifugal Fans with Special Housings and Wheels); Engines. Motors, and V-Belt and Other Drives; Air Filters--Automatic and Cartridge or Renew able Types; Control Devices, including Pressurestats. Thermostats, Humidistats; Turbine Ventilators; Gas-fired Unit Heaters; Special ties; and Other Apparatus for use in conjunc tion with Complete Blower Systems. Complete data and descriptive matter furnished on specific request.
Certified Ratings
Write for Catalogues
Full Catalog Matter, Descriptive Bulletins, Per formance Tables, Engineering Data and Technical Presentation, Prices, and Complete Information with Illustrations will be furnished upon request of District Representative or by Home Office.
990
Since 1889
Air System Equipment Fans and s/o"ers
PROPELLAIR Inc. SPRINGFIELD, OHIO
VENTILATING SPECIALISTS IN ALL PRINCIPAL CITIES
Designed by Propellair to deliver maxi mum air with minimum horsepower. Air flow is even over all of blade--the whole fan works, not just the tips! Non-over loading--from free air to block-off, horse power is virtually constant as long as motor speed is constant. Number of blades, angle and shape, depend on use.
PROPELLAIR
VERTI-VENT
For Roof Ventilation
A fool-proof, auto matic ventilator in stalled easily on roof. Butterfly dampers, v within wind guard, \ offer virtually zero -i---------------------resistance. High velocity, vertical discharge throws heat and fumes far above the roof and prevents rain from entering when the fan is in operation. Dampers close gently and posi tively when fan coasts to a stop. 12 to 60 in. diameters, with capacities from 2100 to 68,000 cfm.
I
PROPELLAIR DRUM-TYPE
Belt-Drive Fans for Heat, Acids, Alkalis, Fumes, Gases or Dust
"CS" and "CSV" drum-type, belt-drive fans for severe, heavy-duty jobs involving elements listed for "CE" type. Sturdy, welded drum construction. Motor com pletely isolated from fan, driving belt protected in steel tube. 20 to 48 in. duct sizes, capacities 2400 to 43,000 cfm.
CURVED ENTRANCE RING
. An Important ' Propellair Feature'
In addition to serving as a sturdy support assembly, jt reduces tip loss and enables Propellair Fans to deliver maximum air per horsepower. Introduced in 1930 as a result of exhaustive experiments and tests by Propellair engineers, this design makes possible the utilization of the "Airfoil" air-movement principle in the entrance ring as well as in the propeller.
PROPELLAIR EXTENDEDSHAFT FANS
For Handling Excessive Heat, Moisture, Fumes, Dust and Gases Type "CE" extended-shaft fans for severe conditions involving excessive heat, moisture, harmful fumes, explosive gases, etc.--where a motor should not operate within air stream. Drive shaft housed and sealed within steel tubing. Special formedsteel ring and support assembly. Fan sizes 12 to 60 in., capacities 2000 to 68,000 cfm.
PROPELLAIR DIRECT-CONNECTED
FANS
For Duct, Wall or Hood, Installation
Type "CD" directconnected fans for wide range of jobs, from free air conditions such as window or panel mquntings, to instal lation in roof ventilators, hoods, or duct work involving medium to relatively high resistance. Successful whenever a motor can operate directly' within air stream. Sizes 12 to 60 in., capacities 800 to 85,000
cfm.
991