Document Em2X0vj8KYGgVbjDkqx66yQrV
Air Conditioning . SeaTT
Campbell Heating Company
3121 Dean, Des Moines 17, Iowa DIRECT FIRED SPACE HEATERS
Oil, Gas, Stoker, Hand Fired or Combination Gas and Oil Fired
DIRECTOR, EASTERN SALES: Nm. Adams, Odd Yobk Road, Lambektviujs, N. J. Telephon'd No. 665
Heater Guaranteed for 10 Years from An; Cause, Blower, Motor, Burner and Controls, for One Year Against Defects.
The Campbell Direct Fired Space Heaters are designed to be located in the room to be heated but they can be con nected to a duct system for heating any type of building and are quiet enough to be used in churches, schools, etc.
They are designed to be shipped as a complete unit ready to connect to fuel line, electric power and flue but they can be shipped in sections for assembling in a basement room. The steel heater is then assembled and welded on the job.
Furnished also for Gas, Stoker or Hand Firing
Unit Num
ber
Output Capacity Btu per hr.
0)
US075 U8100
U8125 U8150
U8175 U8200
U8250
725,000 893,000
1,080,000 1.275,000 1.440.000
1,725.000 3,160,000
Overall
65* Return AirNo Ducts
Heating
Dimensions
Inches Not Inch
Stack
Surface Burner Connection
CFM
SqFt
Dia. In.
for 140* Motor
(4)
(5)
Outlet HP
,W L Ht.
Temp. (3)
(2)
8,850 2-H HP 280 80 80 114
10,900 2-M HP 320 80 93 118
13,200 2-% HP 360 80 105 120
15,600 2-1 HP
440 80 U8 120
17,500 2-1 HP
480 80 130 120
21.100 3-1 HP
600 94 137 136
26,400 2-1M HP 750 94 157 136
12
14 16
16 18 20 20
Firing Rates
Oil GPH
1,000 Btu
GAS C.F.H.
Lbs/H r 1
Approx. .Ship--
ping Weight
Stoker
1 1
7.0
8.5 10.5 12.0 14.0
16.5 20.5
900 1,120 1,350
1,600 1,800
2,150 2,700
80 6.000 100 7,200
125 8,500 150 9,700 175 11,500 200 12,700 250 15,000
(1) Allow 10 to 35 per cent above heat loss for pick up load. If heater is not located in room to be heated an allowance for duct and pther radiation losses should be made of 10 to 15 per cent above heat loss figures.
(3) Rated air volume produces 75 deg air temperature rise through the heater. This air volume can be varied to suit other conditions.
(3) Motor size can be increased to provide for any duct system. (4) Heat Emission per square foot of heating surface is 3000 Btu per hour or less. (5) An induced draft blower can be furnished if a stack or chimney is not available. The gas passages of the
heater are adequate so that an induced draft blower is not ordinarily necessary. Stack connection can be provided through the top of the casing to support a stack through the roof, or out the front as illustrated.
For data on other Campbell ProdtieU eee pages 1158-1159
1178
Air Conditioning
E. K. Campbell Company
Kansas City 3, Missouri HEAVY DUTY FURNACE FAN EQUIPMENT
Standard Units Up To 8,000,000 BTU/HR
Made in Units from 500,000 Btu/hr to 8,000,000 Btu/hr. Available for any fuel or in "All-Fuels" model. Operating efficiencies up to 84 per cent with resultant fuel
economy. Counter-Flow heat transfer. Drive thru principle exclusively (no suction applications), Low Internal resistance to flue gases. Fiberglas insulated casing. Baked enamel exterior finish. Extra Heavy welded steel construction throughout. Available in any required arrangement of duct outlets. Extreme flexibility of equipment arrangements. Balanced job design--blower and furnace sized separately. Sold only on an engineered basis to fit job requirements. Used in thousands of large buildings over country, the E. K. Campbell Co's Type H-D Furnace-Fan system is particularly suited for buildings containing large spaces, such as industrial plants, churches, schools, hangars, etc. High quality equipment, designed to last, giving unusually low cost on a year service basis. The E. K. Campbell Company guarantees RESULTS as well as its equipment. Inquiries Invited regarding LARGE SPACE HEATING PROBLEMS.
Manufacturing Ensineerr tince 1910
1179