Document Edj7VnVNzVmZ5Bn4rMNb4bz1R

ABSTRACT This document presents the findings of a study of available wastewater management and treatment technology for the purpose of determining toxic pol lutant effluents concentrations and daily load achievable in three industrial categories: polychlorinated biphenyls (PCBs) manufacturing; capacitor manu facturing; and transformer manufacturing. All plants in the above categories have PCB discharges to either water ways or sewage treatment plants, under normal operating conditions. All plants have discharges to storm sewers or directly to waterways under heavy rainfall conditions. Extensive survey of wastewater treatment technologies and cooperative laboratory work with several suppliers of treatment equipment and research facilities has confirmed that carbcn adsorption technology is the best current candidate for successful removal of KBs from the wastewaters. As an alterna tive uv-ozonaticn was considered. This technology is still in the research stage; however, it offers potential of ocnplete destruction of PCBs all the way to OOj, water and HC1. Another adsorbent technology now in the development stage, A*ERLHE polymeric adsorbents, has demonstrated a TCBs removal efficiency roughly equivalent to carbon daring laboratory tests. Further testing is needed with this adsorbent to accurately assess its potentiality. Far scrap oils and burnable solid wastes generated at these plants, high temperature, controlled incineration offers a straightforward method of de struction, whereas scientific landfilling appears to be the best suited mode of disposal for nonbumable contaminated solids. Zero discharge objectives can be best achieved by eliminating discharge streams and developing recycle systems. All ncn-oontact cooling water would be segregated, cooled, and recycled. All other wastewater streams tuuld be pretreated, the portion of the pretreated water which would be used in the plant would be treated with carbon, while the excess water would be i. HONS 070354 incinerated in a specially designed system which would allow Car energy zeoonmry. Svpporting data, rationale for the selection of above reocmaended treat ment technologies and associated costs are contained in this report. ii. HONS 070355 TABLE OF CCNUNIS Page SECTION I - INTRODUCTION............................................................................... 1 1.0 OBJECTIVE OF THIS STUDY........................................................................... 1 2.0 SCOPE OF THIS STUDY........................................................................... 2.1 Industry Characterization..................................................... 2.2 Control and Treatment Technologies for PC3s Hastes . . 2.3 Capital and Operating Costs for Selected Treatment Technologies ....................................................................... 1 2 2 3 3.0 REPORT CONTENT...................................................................................... 3 SECTION II - SUMMARY AND CONCLUSIONS........................................................ 4 SBCTICN III - RECCPMENDATICNS....................................................................... 15 SBCTICN IV - HATES! USE AND HASTE CHARACTERIZATION.................................. 18 1.0 introduction........................................................................................... is 2.0 SPECIFIC HATER USES........................................................................... 18 3.0 INDUSTRY AND PROCESS HASTE CHARACTERIZATION.............................. 19 3.1 Manufacturing Process - Polychlorinated Biphenyls (PCBs) 20 3.1.1 Process Description.................................................... 20 3.1.1.1 PCB Production and Usage ....................... 22 3.1.2 Raw Hastes................................................................... 3.1.3 Plant Hater Usage.................................................... 3.1.4 Wastewater Treatment and Housekeeping............... 24 24 27 3.1.4.1 Treatment Facility for the Effluent from Sauget Ocrrplex......................................... 31 3.1.5 Plant Effluents............................................................ 31 3.2 Askarel Capacitor ManufacturingIndustry........................ 32 3.2.1 Askarel Capacitor Manufacturing Plants.............. 34 3.2.1.1 Askarel Handling......................................... 36 3.2.1.2 Process Description .................................. 37 . 3.2.1.3 Raw Hastes.................................................... 42 3.2.1.4 Hater Use.................................................... 42 iii. MOMS 070356 TABUS OF CONTENTS (Oon't) Page SECTION IV (don't) 3.2.1.5 Wastewater Treatment..................................... 46 3.2.1.6 Effluent Ccnposition......................................52 3.3 Askarel Transformer ManufacturingIndustry.............................52 3.3.1 Transformer Manufacturing Plants...............................59 3.3.1.1 Askarel Handling ......................................... 61 3.3.1.2 Process Description......................................62 3.3.1.2.1 Assembly and Askarel Filling Procedure for the Distribution andPower Transformers. ... 62 3.3.1.3 Saw Wastes .................................................... 63 3.3.1.4 Water Use............................................................69 3.3.1.5 Wastewater Treatmoit......................................71 3.3.1.6 Effluent Ccnposition......................................75 SECTION V - SELECTION OF POLLUTANT PARAMETERS.................................................79 1.0 INTRODUCTION..............................................................................................79 2.0 SIQJIFICANCE AND rationale for setaction of pollutant PARAMETERS.............................................................................................. SO 2.1 Polychlorinated Biphenyls........................................................ 80 2.2 Chemical Oxygen Demand (CCD).....................................................81 2.3 Fats, Oils and Greases................................................................82 2.4 Suspended Solids........................................................................... 82 2.5 Dissolved Solids................... . . .............................................83 2.6 Other Constituents....................................................................... 83 SECTION VI - WASTEWATER TREATMENT TCCHN3LOGIES............................................. 84 1.0 INTRODUCTION.............................................................................................. 84 1.1 Similarities and Contrasts Between PCBs wastes and Con trol Practices in their Production, and in their Use as Dielectrics ....................................................................... 84 1.2 Sunmazy of Waste Management ProblemAreas............................ 85 1.2.1 Waste Liquid PCBs and Contaminated Scrap Oil . . 85 1.2.2 FCBb in Wastewaters........................................................ 86 1.2.3 PCBs Contaminated SolidWastes................................... 86 1.2.4 Air Emissions of PCBs.....................................................87 iv. MONS 070357 TAHI OF OOOTENTS (Con't) SECTION VI (don't) Page 1.3 Summary of Current PCBs Waste Control Practices .... B7 1.3.1 1.3.2 1.3.3 1.3.4 Control of Waste Liquid PCBs and Contaminated Scrap Oils............................................................... Control of PCBs in Wastewaters .............................. Control of Solid Wastes Contaminated with PCBs . Oontxol of Air Emissions of PCBs.......................... 87 88 89 91 2.0 CM1DIEATE PCBs WASTE TREATMENT TECHNOIOGIES CONSIDERED ... 92 2.1 Treatment of Waste Liquid PCBs and Contaminated Scrap Oils.......................................................................................... 93 2.1.1 Incineration . . . . ."......................... 93 2.1.2 Sanitary or Scientific Landfill .......................... 95 2.2 Treatment of Wastewaters Containing PCBs....................... 95 2.2.1 Carbon Msorption.................................................... 95 2.2.1.1 PCBs Adsorption Testing by Carborundum Company.................................................... 97 2.2.1.2 PCBs Adsorption Testing by ICI-US ... 98 2.2.1.3 PCBs Adsorption Testing by Calgon corp. 102 2.2.1.3.1 Adsorption Treatment of the Wastarater.................................. 105 2.2.1.3.2 Reactivation of the Granular Carbon. ................................. 106 2.2.1.3.3 Carbon Treatment....................... 107 2.2.1.3.4 Materials of Construction . . 107 2.2.1.4 Carbon Regeneration Alternatives - Wet Catalytic Oxidation .............................. 108 2.2.1.5 Further Applications Data . ................... 109 2.2.2 Ultraviolet-Assisted Ozonation .................................. 109 2.2.2.1 Molecular Responses to Ultraviolet Region Energy ......................................... Ill 2.2.2.2 Photodegradation of PCBs. . ................... 112 . 2.2.2.3 Experimental Factors in UV-Assisted Ozone Oxidation of PCBs...........................113 ' 2.2.214 Destruction of PCBs and Refractory Organics at Houston Research,Inc.. . 114 '2.2.2.4.1 PCBs Destruction Data .... 114 - . -2.2.2.4.2 Operating Data Obtained from - ... Refractory Organics Tests . 114 v. *0NS 070358 SECTION VI (Oon't) TABIE CF CONTENTS (Oon't) Page 2.2.2.5 Destruction of PCBs and Refractory Organics at Vfestgate ResearchQorp. . . lie 2.2.2.5.1 PCBs Destruction Data................. 116 2.2.2.5.2 Pilot Scale Tests of Refractory Organics Decarposition . . . 122 2.2.2.6 Laboratory Test Results from AiResearch Oorp................................................................. 127 2.2.2.7 Contents on UV-Ozone Tests ....................... 127 2.2.3 Non-Carbon Adsorbents for PCBs ................................. 127 2.2.3.1 The Antoerlite XAD Series of Macroreticular Resins..............................................................128 2.2.3.1.1 PCBs Adsorption Testing.... 128 2.2.3.1.2 Process Concept for Resin Ad sorption of PCBs.........................129 2.3 Treatment of PCBs - Contaminated Solid Wastes..................... 130 2.3.1 Incineration..................................................................... 130 2.3.2 Sanitary Landfill.......................................................... 132 2.4 Treatment of Air Emissions...................................................... 132 2.4.1 Condensation Methods...................................................... 132 2.4.2 Granular Adsorption Methods....................................... 132 2.4.3 Catalytic Oxidation of Organics in Evaporated Effluents......................................................................... 132 2.5 The Potential for Zero Discharge........................................... 133 3.0 RATICNAIE AND SELECTIONS OF CURRENTLY RECOEMENDED WASTE TREAT MENT METHODS............................................................................................134 3.1 Incineration Reocnmended for Liquid PCBs and Scrap Oils . 134 3.2 Carbon Adsorption and UV-Assisted Ozonation Reocnmended for PCBs in Wastewater.......................................................... 13b 3.3 Incineration and Landfill Reocnmended for Contaminated Solids............................................................................................ 136 3.4 Dry Carbon Filter Adsorption Reocranended for Control of Air Emissions.............................................................................136 SECTION VII - COST CF TREATMENT AND (CONTROL TECHNOLOGIES.........................138 1.0 SUMftRY....................................................................................................... 138 1.1 Plant to Plant Cost Variations...............................................140 vi. MOMS 070359 SECTION VII - Oon't TABLE OF CONTENTS (Oon't) PAge 1.2 Activated Carbon Terminal Treatment System...........................142 1.3 Costs Based on Volume Flew........................................................ 143 2.0 COST REFERENCES AND RATIONALE........................................................... 143 2.1 2.2 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 Interest Costs and Equity Financing Charges ................... 143 Time Basis for Costs................................................................... 144 Useful Service Life....................................................................144 Depreciation...................................................................................144 Capital Costs ............................................................................... 144 Annual Capital Costs....................................................................144 Land Costs...................................................................................... 144 Operating Expenses....................................................................... 145 Rationale for Incineration Costs . ..........................................145 Definition of Levels of Treatment..........................................148 2.10.1 Effect of Varying Effluent PCB Concentrations . . 148 2.10.2 Zero Discharge Definition ......................................... 149 3.0 PCB WASTEWATER TREATMENT PUNT DESIOJ PARAMETERS AND COSTS . . 150 3.1 Introduction...................................................................................150 3.2 Pretreatment....................................................................... ... . 154 3.2.1 Equalization and Separation Basin.............................. 154 3.2.1.1 Equalization Basin Capital and Cperating Cost................................................................ 156 3.2.1.2 Equalization Basin Costs .......................... 156 3.2.2 Multimedia Filtration.................. 156 3.2.2.1 Filtration Costs ......................................... 160 3.3 Activated Carbon Treatment Systsn for Removal of PCBs Fran Wastewater........................................................................... 160 3.3.1 Activated Carbon System Design.................................. 167 3.3.1.1 Regeneration of Spent Carbon ................... 175 3.3.1.2 Etooncmic Analysis of Carbon Treatment of PCB Contaminated Wastewater................... 178 3.3.2 UV-Ozonation - Potential Alternative........................ 180 3.3.2.1 3.3.2.2 3.3.2.3 3.3.2.4 Description of System Ccnponents and Rationale for Cost Evaluation................... 180 Capital Costs.....................................................188 Operating Costs ......................................... 188 Total Treatment System Cost for Zero Discharge System..........................................200 vii. MOWS 070360 SECTION VII (Con't) TABLE OF CONTENTS (Con't) Page 3.3.2.5 Total Wastewater Treatment Plant Costs Using Activated Carbon or Ultraviolet Light Catalyzed Ozonation ................... 3.3.3 Cost of Implementing Carbon Adsorption Treatment for Selected Plants............................................ 3.3.4 Zero Discharge 3.3.4.1 3.3.4.2 3.3.4.3 3.3.4.4 3.3.4.5 Description of Dry CoolingTower ... Design Criteria......................................... Capital Costs............................................. Operating Costs ......................................... Cost of "Zero Discharge" for Selected Plants...................... .......................... 3.3.5 Ccnparison of "zero Discharge" with Discharge to Surface Waters........................................................ 3.4 Scrap Oil Incineration......................................................... 3.5 Solid Waste Incineration................................ 3.6 Total Industry Treatment Costs . ........................... 200 205 212 212 213 213 213 218 218 222 223 224 APPENDIX A - Plant 106's Position Statement on Dow's XFS-4169 Capacitor Dielectric Liquid APPOJDIX B - PCB Adsorption Testing by XAD-4 Resin APPENDIX C - Description of Macroreticular Resins fran Rahn and Baas Co. APPEK>XX D - Non-Carbon Adsorption and Other Research Stage PCB Treatment Technologies ' .. APPENDIX E - Energy Requiranent for Various Treatment Options viii. HONS 070361 SBCTICN IX SUMMARY AND CCNCLUSICNS The table cm the succeeding page gives a quantitative suninary o daily PCB waste loads achievable by PCB manufacturer and the two major PCBs users (capacitor and transformer industries). This information was derived frem data supplied by these industries and presents estimates of anounts of PCS wastes currently discharged by these industries to the environment via water, land and scrap oil generated and destroyed by these facilities via inciner ation. The results of this study are grouped into three broad categories. First, those dealing with industrial characterization, production, use and emissions. The second group contains those giving an overview'of available technologies for treatment of various PCB wastes and the third summarizes the costs associ ated with currently recommended waste treatment methods. Industrial Characterization 1. The domestic annual production of PCBs in 1974 was 40,466,000 lbs of which approximately 22,000,000 lbs was used by capacitor manufactur ers and 12,000,000 lbs was used by transformer industries. The balance reflects inventory changes and about 5,395,000 lbs of export sales. 2. There are a total of 37 PCB user (capacitor and transformer) plants in the U.S. and one PCBs manufacturer. Of the 38 plants, 10 dis charge their effluents into the water ways while the remainder dis charge PCBs into the sewage treatment plaits. All plants in these categories have discharges under heavy rain fall conditions. 3. In addition to air onissiens, there are three types of waste materi als generated at these plants that require treatment and proper handling in order to minimize the PCB entry into the envirorment. These are: 4 HONS 070362 PCB Manufacturer Capacitor Industries Transformer Industries TABLE 1 SUMMUW OF WASTE LOADS PCB Discharge in waterways cor Sewers 3.06 lbs 5.86 lbs 0.17 lbs Daily Average Iand-Destined PCD Wastes 301 lbs 4440 lbs unknown Scrap Oils to Incineration 1425 lbs 3968 lbs 1750 lbs MCNS 070363 (a) waste waters containing trace quantities of PCBs (10 to 500 ppb PCBs) (b) waste PCBs, scrap oils and small quantities of process water highly contaminated with PCBs (O) burnable and non-bumable solid materials contaminated with PCBs. Quantitative estimates of these wastes are given in Table 1. 4. The quantities of land-destined wastes originating at the PCBs and capacitor manufacturing plants were estimated fron sparse data sup plied by a few plants. Similar information is not available frcm the transformer industry. These plants normally drum their solid wastes and have incomplete information cm the nimber of drums ac cumulated annually. Some plants ocnpact their wastes prior to drum ming; others drum their wastes without the benefit of compacting. There are no adequate records to quantify these wastes. At sane plants, the majority of this waste category, however, exists in an enormous total waste volume and prcbably at relatively low concen trations of PCBs. Further efforts are needed to adequately define these wastes. 5. As yet, very little is being done to control air emissions. The general assumption is that the vapor pressure of PCBs is so low that there will be essentially no air contamination. A few facilities, however, were reported to be filtering and chilling exhaust air fron PCBs impregnation areas. 6. Vtiile the emissions of PCBs to water are expected to decrease due to improved pollution abatement of waterborne wastes, the release of PCBs to air and land is expected to increase. The primary source of increasing air emissions is the increase in the load of incineration materials due to proper handling of wastes vhich were previously discharged into the waterways or sobers. The quantities of landdestined wastes will also increase due to improved housekeeping measures. 6 HONS 070364 7. Since most water used at these facilities is for non-contact cooling purposes/ at most plants it is possible to significantly reduce the effluent volune by segregation of wastewaters, recycling and proper housekeeping measures. 8. Most plants have already undertaken PCBs containment program in order to minimize the entry of PCBs into the environment. 9. Thera is no ccntnercial scale wastewater treatment for PCBs removal being practiced bteyond those of gravity settling of the heavy PCBs layers as a sludge fran the bottom of strips or tanks, and skinning of a contaminated oil-layer from the water surfaces. 10. Wastes in PCBs production and PCB wastes in capacitor and transformer manufacturing differ primarily in that the producer generates sane higher boiling, highly chlorinated and polycyclic materials referred as "Montar" that are separated from the Aroclor products and in cinerated. Thus the users of PCBs do not receive the higher boiling materials. Aroclor 1016 is the principal PCB used by capacitor industry; at sane plants Aroclor 1242 and 1221 are also being used in limited quantities. Mineral oil is the principal coolant oil used by the transformer industry. PCB transformer oils (blends of 60 to 70 percent Aroclor 1254 or 1242 and 40 to 30 percent trichloro benzene) are used in only 5-10 percent of these plants' manufacturing volute. However, it has been concluded that the characteristics of the waste materials and effluents generated in all these facilities are, in general, similar enough so that the same kinds of treatment technologies can be utilized for purposes of controlling PCB entry into the envirorment. 11. Most industrial analysis for PCBs in wastewaters are based on grab sanples and probably have not been more accurate than about - 504 at the one and ten ppb level. 7 MONS 070365 12. Rivers receiving FCBs discharges far a nunfeer of years vary greatly in FCBs content with time, apparently depending upon FCB content in storm water runoff and the degree to which bottom sediment is agi tated and suspended. 13. Wherever there have been PCS operations in the past, there are proba bly high concentrations in local waterways bottom sediments. 14. All water streams have greatly lowered PCBs aontents: (a) when solids are removed (b) when dispersed or dissolved oils are removed (c) When the stream cotes in contact with a wide variety of solid surfaces (d) when no surface active agents are present. 15. Over the past 45 years, waste PCBs from transformer and capacitor operations have been used as local road oiling compounds. Sometimes they were discarded in dunps adjacent to manufacturing facilities. These are sources of long term leaching of PCBs into waterways, par ticularly with storm water runoff. Overview of Available Technologies for the Treatment of Various PCB Wastes 1. The most advanced treatment technology in use is incineration. The PCBs manufacturer and one user have plant scale incineration capable of destroying PCBs with very high efficiency. There are at least two osmrercial services (Rollins Environmental Services and Chemtxol Pollution Servioes) available, with four incinerator locations in the Eastern and Southern U.S., that destroy PCBs. 2. Incineration is primarily applicable to waste PCBs and scrap oils contaminated with FCBs. All installations have the capacity of "burning" seme contaminated wastewater but, of course, the pro portion of that water to the exothermic oil burning must be kept low. HONS 070366 3. Only one commercial incineration service (Rollins) can routinely handle all kinds of PCBo contaminated transformer and capacitor ccxnpcmanta, sledges, fuller's earth and other solids, as long as they can be contained in a 47 gallon fiber dmn. One PCB user company incinerates transformer internals for purposes of metal recovery. 4. Adequate methodology is available for those plants wishing to con trol the release of PCBs to the environment. Currently available technologies can be applied to the efficient removal of PCBs from wastes, or their destruction with the other wastes, 5. The PCBs content of wastewaters can be lowered to the 1 ppb level or below by carbcn adsorption, macroreticular polymer resins and proba bly other adsorbents. 6. Carbon adsorption is currently the best available technology for plant scale treatment of PCBs wastewaters. This conclusion is based cn laboratory tests with PCBs in water, and cn the long background of plant scale use of carbcn adsorption for removal of organics from water. 7. UV-ozcnaticn technology is the best demonstrated method, on the labo ratory scale, for destruction of PCBs in wastewaters when the streaiB occur in large volume, cn a relatively continuous flew basis and with PCBs at the ppb ccnoentraticn levels. This technology has the po tential far conversion of PCBs to CDj, H^O and Hd. B. Waste liquid PCBs and scrap oils contaminated PCBs are best handled, as a guideline, by high temperature (2000-2400F) and long residence time (2-3 eeconds) incineration. However, because of incinerator design variables, the ocnditlcns should be chosen in each case to lead to 99.9994 destruction. 9. Incinerators should be equipped with low temperature alarms, and low temperature shut down of PCBs feed. They should have high efficiency water scrubbers to prevent HC1 dissemination. 9 MGNS 070367 10. Hue best incinerator oonbination for handling wastes frcm these in dustries is a rotary burner fired by a liquid burner, and followed by an afterburner and scrciaber system. The rotary burner can be designed to handle a variety of solid materials, and the liquid burner can handle both the oily and water type wastes. 11. Polymeric resins (JWBEKLECES) were found in laboratory tests to be approximately as effective as carbcn in removing KBs frcm water. Further pilot scale testing is needed with this newer (than carbon) technology to accurately assess its potential. 12. Although still in the laboratory stage, catalytic reduction of KBs offers the possibility of reduction to biphenyl and HC1; and cata lytic oxidaticn offers a potential for destruction of PCBs to 002 20 and HC1. 13. Reverse osmosis and ultrafiltration appear to offer a long term po tential for a more maintenance-free, and lcwer operational cost method of separation of PCBs from water. Success is dependent upon specialized mstbrane development now being carried out at several facilities. 14. It is believed that treatment systems employing activated carbcn end possibly UV-ozonation oculd produce effluents which would be at or below the limits of detectability for PCBs with currently available analytical techniques. However, since no full scale systems for the treatment of KBb are in operation at this time, this possibility cannot be confirmed. 15. Unfortunately, no methodology is presently available which can guarantee "zero discharge" to the environment. "Zero discharge" ob jectives can be best met now by eliminating discharge streams and developing recycle systems. All streams that are high in pollutants and can't be treated for reuse and the rainwater runoffs should be collected and incinerated. 10 0AS 070368 Oasts Associated with Currently Beoctcroended Waste Treatment Methods 1. Tha Table on the succeeding page sumnarizes the estimated maximun capital and annual costs for the treatment of wastes generated in each industry category. As shown treatment of all contaminated and potentially contaminated wastewaters, the incineration of scrap oils and the incineration of aantatinated solid waste generated in the domestic production and utilization of FCBs is $35.50 million and $9.61 million, respectively. The total annual cost given above represents $0.28 per pound of PCB utilized within the U.S., based on 1974 data. 2. Rainwater contribution to tha capital and annual wastewater treatment costs was estimated at 15 and 25 percent, respectively. If significant isolation of the contaminated areas can be achieved these costs will be sonadiat reduced. 3. The estimation of total maximum costs anticipated for the manufacturer and users of FCBs was facilitated by preparing cost estimates for each plant site visited during the course of this study and then aggregating to the total industry category cn the basis of the percentage of the total industry represented by the visited plants. 4. The treatment syBtam includes settling for solids removal, oil skimriing, equalization, fine media filtration, terminal PCB treatment, flow measure ment and sailing, and discharge to surface receiving waters. All sludges and free floating oils are disposed of through incineration. All backwash waters used in the system are recycled back to the gravity settling basin for treatment. All spent adsorbent is destroyed by incineration (far wastewater flows up to 300 gpn) or regenerated on-site for reuse (for waste flows above 300 gpm). 5. An activated carbon system was selected as the terminal PCB treatment method for purposes of estimating the maximum total costs. A potentially viable alternative to carbon adsorption, UV-oaonaticn, has less well de fined capabilities. Additionally, it is believed that unless (die UVozonation system can do an equal or better jcb of destroying PCBs at a lower cost, it will not be selected by these industries. 11 HONS 070369 TABI 2 MAXIMUM PCS DTOSTTO TREATMENT COSTS industry Capital Cost Total Annual Cost PCB Producer Capacitor Manufacturing Transforrrar Manufacturing Total $ 1,600,000 16,600,000 17,300,000 $35,500,000 $ 595,000 4,200,000 4,815,000 $9,610,000 Total Coat Per Pound of PCS utilized Total COst Per Pound of PCB discharged to waterways $ 0.28 $ 2896 Ooet Per Pound Produced or Used $0,015 0.190 0.401 12 HONS 070370 6. A carbon adsorption system will remove PCBs from industrial effluents to a level of one ppb or less. It is impractical to design an activated carbon system to obtain a choice of effluent concentrations. The operat ing coat savings for operations at various effluent PCB concentrations are expected to be too small to justify designing carbon adsorbers far KBs removal at higher than one ppb level. 7. The work performed by Houston Research and Westgate Research on UVozonaticn indicates that the final acnoentraticn is a function of resi dence time, and that CV-ozcnation systems can be designed to achieve any desired effluent PCB concentration. 6, Preliminary conparisons of the capital costs of the two systems show at least a 100 percent greater oost for the ozone aystan over the carbon. When pretreatment costs are combined with treatment, the UV-ozonation process is about 10 percent higher than the carbon process. 9. The design and fabrication of incineraticn equipment is a highly proprie tary industry, it is believed that any attempt to estimate the cost of such systems on a rational basis would be fruitless. In addition, it seems quite improbable that the smaller PCB user plants would find it eooncmically justifiable to install aid operate such a system for de struction of scrap oils and solid wastes contaminated with PCBs. The al ternative to cn-site incineration is contract incineraticn. For purposes of cost estimation and based on the range of prices quoted by service corpanies, a flat rate of $0.10 per pound has been assured for all scrap oil aid solid wastes even if they are generated by facilities which have an an-site incinerator. 10. Contract incineration of large volime, dilute aqueous streams does not seem to be a feasible alternative due to the logistics and transportation cost. For purposes of achieving "zero discharge", capital costs for cnsite incineration systems were developed. In this case, the accuracy of capital cost estimates are not domed as critical in view of the high operating oost, primarily fuel cost, associated with this syston. 13 CHS 0 703 71 11. The least oost "zero discharge" system comprises segregation of waters used in the plant and cooling and recycling all non-acmtact cooling water. All other wastewaters will be routed to a central syston for equalization, settling and fine media filtration. Hie portion of the water to be utilized in the plant will be subjected to terminal treat ment with carbons, the excess water will be subject to incineration in a specially designed system vhich would have the potential of energy recovery. 12. Capital and total annual costs to achieve 'zero discharge", based on the system described above, was developed for selected plants. It was con cluded that the total annual costs for "zero discharge" was about 2.0 to 12.0 times the oost of the carbon system (close loop cooling water case; then rainwater was included. 13. Rainwater runoff is a direct function of the locations' rainfall and run off area. The rain runoff area may or may not be dictated by the size of tlae production facility. This single flew could provide the largest flow variation for all production facilities. 14. For the "zero discharge" system the rainwater contribution to the annual wastewater incineration oost is vary high. Ocrparison of the two "zero discharge" cases i(1) inclusion of rainwater runoff as incinerating material and (2) exclusion of rainwater runoff ] indicates the annual oost of the case 1 to be 2 to 42 tines the oost of the case 2 for the various plants under study. 15. As a rough approximation, energy requirement far waste incineration is directly proportional to the hydraulic load of the imit. Hater inciner ation is far more energy intensive than scrap oil incineration. 15. Energy requirement of each plant is proportional to the total hydraulic load of the pretreatment and terminal treatment systems. 14 MQNS 070372 SECTION III EBOOMEMDWICNS There are indications within the PCBs manufacturer and PCBs user indus tries that progress is being made in air and water pollution abatement; how ever, little is being dene to assure that the land-destined wastes are dis posed of in an environmentally sound manner. This shortcoming can be attributed to higher costs associated with handling large volumes of wastes fijrther information is needed regarding methods and costs of handling landdestined wastes. Based on the summary and conclusions cited in Section II, the following reoenmendations are made: 1. Verification sampling should be conducted under controlled conditions in order to define the levels of PCBs discharged into the environ ment with higher degree of accuracy. 2. Promulgation and enforcement of regulations for water pollution abatement from stationary sources should be continued. Regulations for non-point sources should be initiated to minimize the entry of PCBs into the environment. 3. The use of more biodegradable PCS (Aroclor 1016) in transformer ap plications should be encouraged. 4. New regulations should be developed and enforced to ensure that the land-destined wastes from these facilities are disposed of in an en vironmentally sound manner. 5. Additional data should be developed to adequately characterize solid wastes generated by these three industries and then define methods and costs of handling these wastes. 6. The capability of various incineration facilities should be deter mined for PCBs destruction on a given doctored feedstodc using a pre developed and specific test plan. Analysis of available data indi cated that there are differences of opinions as to optimum tempera ture level and residence time for PCB incineration. 15 HONS 070333 7. Haste PCBs liquids and scrap oils contaminated with PCBs should be incinerated in approved facilities. New incineration facilities can be installed in cne year. 8. Every effort should be made at each plant to minimize flows. Hie source of rain runoff contamination should be traced and efforts should be directed to isolate the contaminated areas. 9. Disposable foot coverings and outer garments should be provided at each plant; vrork clothing should not be allowed to leave the plant other than via solid waste. 10. All spills should be cleaned via rags or floor dry and disposed of in waste drums for incineration. All solid waste should be disposed of in impervious sealed containers. 11. As a housekeeping measure, all sinks in the PCB impregnation and PCBs handling areas should be contained. Hie wash water from these sinks should be properly treated prior to disposal. 12. Wastewaters containing PCBs should be treated by the standard sani tary procedures of settling the sludges and sediments, removal of suspended solids, and skimming to ranove floating oils; all prior to specialized terminal treatment for PCBs. 13. Wastewater pretreated as recommended above should then be treated in carbon adsorption columns for removal of PCBs to the ppb levels or. less. Spent carbon should be regenerated in an environmentally sound man ner, or sent to approved incineration along with other PCBs wastes. 15. Waste capacitor and transformer components, absorbent solids, adsor bents, soil, cloth, paper, wood and similar solids contaminated by PCBs should be incinerated in a rotary kiln. Hu exhaust should be fed to an incineration unit for liquid PCBs, equipped with after burner and scrubber to assure destruction of all PCB vapors. Sucb facilities can be installed in cne year. 16 MQNS 070374 16. Exhaust air from PCB impregnation areas should be filtered through absorbent carbon, with chilling, if necessary, to meet clean air quality standards. This equipment can be installed in one yaar. 17. Research on the catalytic oxidation of dilute PCB vapors in air streams should be conducted to determine the feasibility of low terperature destruction of PCBs by an energy saving process. This method will take more than three years to develop. 18. Research on UV-ozonation should be continued to achieve the follow ing goads: a) determination of optimum conditions for a continuous flow reactor system using actual wastewaters b) conduct on-site demonstration tests using portable equip ment at a PCB using plant, operating on a wastewater slip stream c) design, construct and operate a pilot unit, on actual wastewater, to develop reliable capital and operating cost UV-ozonizaticn treatment technology can be fully developed and in stalled in three years. 19. Pilot scale R&D an reductive dechlorination should be continued to obtain reliable capital and operating costs. This method will proba bly be available for plant scale application in three years time. 20. Laboratory research on catalytic oxidation as a method of PCBs des truction should be initiated. The feasibility of wet catalytic oxidation using suspended commercial catalysts at elevated tempera tures (200-500C) and elevated pressures (500 to 1000 psi) should be determined. This method will take more than five years to develop. 17 MONS 070375 . Treatment and housekeeping measures practiced at the facilities and on-going PCS containment programs . Plant waste effluents found and their exposition 3.1 Manufacturing Process - Polychlorinated Biphenyls (PCBs) ' 3.1.1 Process Description Monsanto, the sole donastic manufacturer of PCBs, manufactures this chemical in their Sauget, Illinois plant. The basic raw material is biphenyl Which is manufactured fren pure benzene in another Monsanto plant. The PCB manu facturing operation is conducted in two steps. First, biphenyl is chlorinated with anhydrous chlorine in presence of ferric chloride to produce crude PCBs and than the crude PCBs are distilled to obtain the finished product. A schematic flow diagram of this process is given in Figure 3.1.1-1. The reaction section consists of 6 reactors (3 batch and 3 cascade). Currently Monsanto manufactures four different types of Aroclors (1242, 1016, 1254 and 1221). For the manufacture of any given product, the chlorinator is charged with proper quantities of biphenyl and catalyst and heated beyond the melting point of biphenyl. The flow of vaporized chlorine is then started and the charge is circulated with a puip. Throughout the chlorination, the temperature is kept above the melting point of the mixture, but below 150C to ovoid excessive sublimation and plugging of the line discharging the hydrogen chloride produced by the chlorination. The reaction pressure is maintained near atmospheric. The degree of chlorination is principally determined by the time of contact with anhy drous chlorine. The contact time varies from 12 to 36 hours for the manufacture of different Aroclor types, ihe degree of chlorination is measured by the specific gravity Of mixture or the ball and ring softening point when the product is viscous. The vapors from the chlorinator (HC1 containing PCBs) are fmihhod with liquid Aroclor and the gaseous BCl is sent to another plant at the Sauget ocnplex for purification. The crude product is held at an elevated tem perature and bloon with dry air for several hours, after which it is sent to the nw Aroclor storage tank where a few tenths of 1 percent of alkali is stirred 20 HONS 070376 Figure 3.1J-IA* PREPARATION OF CRUDE CHLORINATED BIPHENYLS-MCNSANTO KRMMRCH PLANT jvCMT Figure 3.I.I-IB-DIST1LLATION OF CRUDE PRODUCTS'MONSANTO KRUMMRICH PLANT RAW AROCLOR I ?T^*M j_________ p--H^O VAPOR 6AS FIREO RETORT VACUUM OVCRMCAO DISTILLATION BOTTOM I a, -MCI TO PURIFICATION I --___ iL--_ SCRUBSCR | (CASCAOC REACTORS) CHLORINATION SECTION STORAGE \ AS ABOVE ) SHELL a TUBE CONDENSER STEAM JET EJECTORS - AROCLOR 016 NON-CONTACT 1 COOLING WATER |1 1 STILL 1____ ({VACUUM}) CONDENSER IT* STEAM JET EJECTORS V MDCMSATC - AROCLOR 1294 - MONTARS TO INCINERATION I t t O iO SNOW with the material to react with any remaining hydrogen chloride or ferric chloride. Dm air from the blcwer tank is scrubbed with water and vented to the atmosphere through a demister. The raw Aroclor is subsequently batch distilled under reduced pressure to remove the color, and the traces of hydrogen chloride and ferric chloride. The methods of purification are different for the different types of and products. Raw Aroclor 1254, 1242 and 1221, each are distilled in stills under reduced pressure, achieved via steam jet ejectors; the condensate from the still is the finished product while the bottoms are the Montars which are druimed and aent to incineration. Hie distillation section for the 1016 product consists of a gas fired retort and a vacuum distillation tower. The latter is used to allow the separation of the higher chlorinated, less biodegradable compounds from the relatively later chlorinated and more biodegradable ones. The raw Aroclor (421 chlorinated material) is fed into the reboiler. The vacuum in the tower is main tained at about 100 mg Hg via steam jet ejectors. The steam is partially con densed and the condensate is discharged into the plant discharge sump. The first cut fron this tower is recycled back to the retort. At a preset overhead temp erature the 1016 product is collected and sent to the product storage. The high boiling residue from the tower is sent to a subsequent chlorination cycle and the resulting raw Aroclor is distilled in a still. The overhead fron this still is the finished product. The bottoms fron this tower are the Montars, which are aant to incineration. For special orders, in order to increase electrical resistivity, the Acoclors are stirred, at an elevated temperature, with a few tenths of It of well-dried fuller's earth and then filtered through paper. All Aroclors are stored at 150F. Steam coils are used on the storage tanks for heating these tanks. 3.1,1.1 PCS Production and Usage The William G. Krunmrich plant at the Sauget complex has an annual design capacity of 48 million pounds chlorobiphenyls. Table 3.1.1.1-1 22 HONS 070378 TABLE 3.X.1.1-1 PCB MANUFACTURE S. SALES U.S. production Domestic sales U.S. export sales (Thousands of pounds) 1974 First Quarter 1975 40,466 34,406 5,395 8,532 7,986 1,538 Domestic Sales by PCB Grade Aroclor 1221 Arodor 1242 Aroclor 1254 Aroclor 1016 57 6,207 6,185 21,955 10 2,201 2,115 3,660 Predcminant Utilization of Aroclors Aroclor 1221 & 1016 Aroclor 1242 6 1254 Capacitor applications Transformer applications 23 MCNS 0 703 79 fCMent data from Monsanto related to production and sales on PCBs for the year 1974 and the First Quarter of 1975. Table 3.1.1.1-2 presents approximate molec ular oarrposition of these Aroclors as published by Hutzinger et al (0. Hutzinger, 8. Safa and V. Zitko, "Chemistry of PCBs", CSC Press, 1974). The majority of the PCBs produced in this plant is marketed domestically. At present, almost all Monsanto's PCB production is being used in 'closed electric systems" (transformer and capacitor applications). 3.1.2 Raw Wastes The raw wastes from the manufacturing area oonsist of the liquor from the scrubber, the condensate from the steam jet ejectors, water used for showers and eye baths, miscellaneous floor wash dams, waste oil collected in drip pans and druns, and montars which are the bottom cut from their stills. The composition and the quantities of the individual waste stream are not monitored. All affluent streams generated in the manufacturing area are directed into the Maps In this area. The waste oil collected in the drip pans and the montars are emptied into 55 gallon drums and sent to incineration. The raw wastes generated in the incinerator consist of the wituri scrubber liquor and the water phase from the separator but? in the incin erator area. The composition of the combined stream is monitored. However, the composition of the individual streams is not known. Mon-product PCB discharges an shown in Figure 3.1.2-1. It has been estimated that this plant generates sbout 25 lbs. of scrap oil and Montar per ten of PCB produced. Additionally the quantities of material sent to landfill approximates to 5.4 lbs. per ton of PCB produced. Additionally, reports that the plant's PCB contribution to air is under 1 lbs/day. 3.1.3 Plant Water Usage On the average, the PCB plant uses a maximum of 388,800 gallons of water and a maximum of 360,000 lbs. of steam, daily. Hater is used for non contact cooling purposes in shell and tube condensers, in a water scrubber, for floor washings, for shouars and in eye baths. Steam is used in the steam jet 24 HONS 070380 TABLE 3.1.1.1-2 APPROXIMATE M3LECUIAR COMPOSITION OF AROCLORS Chlorobiphenyl C12H10 Ci2H9a 1221 11 51 Aroclor Type or Grade (percent ocnfosition) 1242 1254 <0.1 <0.1 1 <0.1 C12HBCl2 C12H7C13 32 16 0.5 4 49 1 2 25 21 Cl2H5a5 VA c12H3a7 C12H2C18 c12Hia9 C12Cl10 0.5 8 48 ND 1 23 ND <0.1 6 ND ND ND ND ND ND K> ND ND 1016 <0.1 1 20 57 21 1 <0.1 ND ND ND ND M> - Denotes non-detectable 25 MCNS 070381 ?SFO0 snow Fiflur3.l.2-I-NON-PRODUCT PCB DISCHARGES AT MONSANTO'S KRUMMRICH PLANT VAPOR FROM JET EJECTORS------------------------EXHAUSTS FROM THE SCRUBBER----------------SURFACE AREA EVAPORATION (IN GENERAL) CONDENSATE FROM STEAM EJECTORS-----NON-CONTACT COOLING WATER-----------------SCRUBBER LIQUOR ;----------------------------------------- MONTARS------------------------------- --------------- -------- BOTTOMS FROM SEPARATOR SUMP----------COLLECTION FROM ALL DRIP PANS -- RAGS FOR CLEANING----------------------------------FLOOR DRY----------------------------------------------------- SPENT FILTER PAPERS B FULLERS EARTH ------------------------------------------ AIR TO SEWERS INCINERATION LANDFILL I I I joctora and for steam tracing purposes. fta plant uses municipal water and purchased steam. lbs process water frcrn this facility consists of the liquor from their scrubber and the steam condensates which are discharged in one of the two snips in the manufacturing area. Additionally, 273,600 gallons of water are used In the Incin erator daily for quenching the hot gases from the fire box. The resulting weak nuriatic acid in the quench pot is used in the venturi scrubber and in the packed tower. The type and quantities of water used and discharged at this plant are sixttnarized below. Water Balance Manufacturing Plant Quantities, GPP Process Hater in water scrubber mi.sc. floor wash downs condensate from steam jet ejectors Non contact cooling water showers, eye bath condensate from steam tracers Total Peed 14,400 7,200 -- 360,000 7,200 -- 388,800 Discharged 14,400 7,200 14,400 360,000 7,200 28,800 432,000 Incinerator water used for hot gas quenching water phase from the simp Total 273,600 -- 273,600 273,600 14,400 288,000 3.1.4 Wastewater Treatment and Housekeeping Monsanto reports significant environmental controls at their Knxonrich, Sauget plant. Since 1969, they have invested more than 22 man-years of work and millions of dollars in this program. The in-house goals have reduced the FCB discharges into water to about three pounds per day. 27 MCNS 070383 A John Zink designed incinerator was erected at Sauget in 197. to safely dispose of PCBs. A schematic flow diagram of this operation is given in Figure 3.1.4-1. Aroclor is steam atomized and fed into the fire box. Natural gas is used for ccnbustion and the feed is incinerated at temperature above 2200"F at 5 percent excess oxygen with a retention time of 2-3 seconds. The gases are quenched with water and the exhausts from the quench pot are passed through a high-energy venturi scrubber, then through a packed column which is irrigated by the week muriatic acid originating from the quench pot. Exhausts are then vented to atmosphere through a demister. These exhausts as well as the effluent from the incinerator section are nonitored. In the incineration area, drainage is directed to trenches and piping which flow into a 10,000 gallon underground concrete basin. The water layer from this basin is pimped continuously, combined with the scrubber liquor, metered, monitored and discharged into the sanitary sewers of the Sauget complex and from there it is sent to the East St. Louis municipal sewers. The organic phase from the sump is periodically punped into waste storage tanks for inciner ation. The incineration unit has a rated design capacity of 10 million pounds per year. However, since the start of its operation this unit has achieved a service factor of about 0.60. Monsanto reports that this incinerator can achieve a maxinun of 6 million pounds of capacity annually; the unit is plagued with various nachanical problems. Monsanto uses their incinerator to process both their own wastes and as a service to other industries. Tire service charge for incineration is an average of SO per lb. of material, but the cost appears to be increasing. The incinerator feed is brought into the plant either by truck in 55 gallon sealed drune, by tank trucks or by rail. The drvms are opened, picked ip by a fork lift and emptied into a concrete pit. The tank truck carrying the waste liquids enters the incinerator area and the liquid waste is then pimped from the truck into the pit. The material in this pit is periodically puiped via a vertical oertrifugal pimp in one of the four 20,000 gallon, each, incinerator waste feed tanks. 28 HONS 070384 FkMre 31 4-1-PROCESS FUOW DIAGRAM OF THE JOHN ZINK INCINERATOR. AT MONSANTO'S KRUMMRICH PLANT 8 seeoto sno* fin nil car is brought into a designated area close to the Incinerator site. The material fron the rail car is normally puiped into a long term, 500,000 gallon storage tank. The material fron this tank is pimped into the incinerator feed tanks located an the incinerator pad, when required. Drainage is provided along the rail tracks. These drains enpty Into tha 10,000 gallon simp located 'under the incinerator pad. In the manufacturing area, Monsanto has taken a nuiber of significant steps to prevent loss of PCBs to the environment. Drainage is directed to trendies and piping, and then to one of two concrete 3,000-gallon underground settling basins. Oris insures PCB containment in case of accidental spill or equipnnt failure. Relief valve lines and atmospheric vents are routed through catch tanks, or are redirected to settling basins. When snail quantities of PCBs are collected in the settling basins of the manufacturing area they are later punped into 55 gallon dram, and eventually incinerated. The overflow fron these simps is combined with the non contact cooling water used at the plant, monitored and then discharged into the Sauget carpiex's sanitary sewer and from there to the East St. Louis municipal System. PCBs are packed and shipped in galvanized-steel 55 gallon dni"s, or in railroad tank cars. All tank cars are top loaded. In the drum filling area spills are cleaned via rags or floor dry and these materials are dnmried and Bant to landfill located in the town of Sauget. In the PCB truck or rail car loading area drainage is directed into a snail ooncrsta pit. Ae material aocumilated in this pit is periodically pimped into the basins located in the manufacturing area. Nitrogen blanketing is provided on storage tanks to eliminate any "breathing" of tha tanks and resultant PCB escape. Mist eliminators have been installed in vapor lines to eliminate the possibility of PCBs leaving the manufacturing area through these lines. 30 MONS 070386 -1 . Finally, underground sewers have been replaced with abovegrouid sewers, and repaired or combined with others, so that the effluent fran the department can be monitored. In addition, this step will prevent any unknown WiMAy of PCBs in the sewer systems or any contamination of fcbs into other A high housekeeping level is maintained in the plant itself. Housekeeping responsibilities which the operators have assured are as follows: . All pulps are checked far leakage on every shift. Drip pans that collect leaks are aiptied into scrap PCB druns. . All leaks are reported and documented so that corrections can be made and settling basins observed. . "Floor Dry" is used to absorb any PCBs that have spilled or leaked. If it becomes necessary to flush PCBs to the settling basin, a minimus - amount of water is used. . Sarpling druns and scrap PCB druns are quickly palletized, labelled and transferred to the in cineration area. 3.1.4.1 Treatment Facility for the Effluent from Sauget Oonplex 1 The processing and incineration departments' aqueous effluent enters the plant sewer system, and this system discharges into the Sauget Village waste sewer aystem. The combined streams then flow to the village primary treatment plant. The village treatment plant is under expansion to a secondary chemical treatment plant, scheduled for 1976 ccnpletion. Additionally, evaluations are being conducted to Include the village plant discharge in a projected regional biological treatment plent. ' ' 3.1.5 Plant Effluents This plant has no point source discharge frcm their operation, there is a single discharge frcm the manufacturing operation (the ocnbined stream of process and non-contact cooling water) to the main sewer system of the Sauget 31 *CNS 0 j complex aid than la a second discharge from the incinerator area to the saaa 11-nr systan. The composition of these streams as reported by Monsanto are as follows: flow rate, gpd PCSs, pin PCBs, Ibt/day Effluent from the Manufacturing Operation 432,000 0.75 2.70 Effluent firm the Incineration area 288,000 0.15 0.36 It has been reported that these effluents are clear liquids with essentially no suspended solids. The incinerator effluent my contain sane mounts of chloride. However, no information is available on the chloride content. 3.2 Aakarel Capacitor Manufacturing Industry Presently 90-95 percent of all capacitors manufactured in the U.S. are of the PCS impregnated type. Two important types of capacitors are phase correctors on power lines and ballast capacitors for fluorescent lighting. Aroclor 1016 is the principal FCB used In this application; at sane plants Aroclor 1242 and 1221 are also being used in limited quantities. The principal types of Aroclor impregnated capacitors and their applications are given below. A. High voltage Power Generally AC capacitors are used to improve the power factor of a circuit. Manor factor is the ratio of true power in watts to the apparent power as obtained by multiplying the current flowing to the load by the circuit voltage. The power factor correction can be mode directly at the lead or at utility substations. In the latter case high voltage units will be designed for 4,800 to 13,800 volt service. 1b the utility engineer the use of capacitors is purely a matter of economics. The main benefits that result from the use of capacitors are: 1. induction of losses associated with the delivery of electrical power to the point of use. 32 MOMS 070388