Document Edg6dndn0rk0zq5jvpVM7yGog

2 -K UNION CARBIDE CORPORATION CHEMICALS AND PLASTICS ENGINEERING SOUTH CHARLESTON, WEST VIRGINIA MEMORANDUM February 22, 1973 fteceriveo 23 1273 r / j. ports' R. Turner E. 0. Garrett D. R. Matheny/G. R. Monk J. J. Potter, JrV C. J. Swan, Jr. (6) ^MMUNICAr/ON COP *s*roy Aftr Ue y Pile No, Coplea D. V. Moody, Jr. C. C. Beely J. E. Repp J. L. Slapeon rRSULATIOK-EESIGR CRITERIA 8PIRIT8-CRATE ETHANOL RBFIHEMEOT ETHANOL PIART BO. 12 TEXAS Cm, TEXAS Following are the recommended material and thickness specifications for each anticipated service condition: Temperature . Material Insulation Service Ranee Specification Thickness Process - Piping and Equipment Procesa - Piping Process - Equipment Process Equipment - Subjected to Cyclic or Thawout Temps. Utility Piping (Steam, Water, Air, etc.) Above 50'F Belov 50*F Belov 50*F Belov 50*F normal (up to ltOO*F thawout) 50*F to 250*F 1A<2> 1M 1K-B TIM-101-515 TIM-lll-515 TIM-111-515 TIM-lll-515 3A ' t. tt Utility Equipment (Steam, Water, Air, etc.) 8team Traced lines or (k) Equip. 50*F to 250*F All temperatures j^3) 2A(1) TIM-101-515 Personnel Protection - Piping 135*F to 250*F Personnel Protection - Equipment 135*F to 250*F ^3) UCTC 17273 >*2* it*.- Service Personnel Protection - Piping or Equipment 2 Temperature Range 250*F and above Material Specifications and) Insulation Thickness TIM-lte-515 Tire Protection - Piping and Equipment Tire Protection - Piping Tire Protection - Equipment Wote Above 50*F 50*F and below 50*F and below w(i> 1A<2> 1M TIM-133-515 TIM-13lt-515 TIM-13U-515 (X) All valves, fittings and other Irregular surfaces shall receive a mastic weather harrier. (2) Aluminum Jacketing used In services operating below 50*F shall have a baked-on acrylic enamel finish on the outside to prevent condensation. (3) On smell equipment where spraying of urethane would he impractical, Material Specification 2M may he used. (k) for steam operating at 1*00*F or less, copper traclj shall he used. For steam operating above 1*00*F, stainless steel tracing shall he used. Because of restrictive regulations Imposed by the Occupational Safety and Bealth Administration (OSHA), the Texas City Plant has adopted a policy stating that no new asbestos-containing Insulations shall he installed on new Installations. Material Specification 2A presently approves calcium silicate products which still contain asbestos fibers. By the time material procure ment is necessary, asbestos-free products will he readily available; there fore, the material for Specification 2A should he one of the following: Kaylo 10-AF - Owens-Coming Fiberglaa Corp. Thermo-12 - Johns-ManviHe Corporation 8uper Caltemp, type XA - Pabco Industrial Producta This criteria la being issued for simultaneous review and preparation ofInsulation and Beat Tracing Schedules. Any consents should be directed to UCTC 172*74 UNION CARBIDE CORPORATION CHEMICALS AND PLASTICS ENGINEERING SOUTH CHARLESTON, WEST VIRGINIA February 22, 1973 MEMORANDUM FEB 23 1973 / J. PCxxjg^ R. Farmer X. 0. Garrett D. R. Netheny/G. R. Hook J. J. Potter, Jr* C. J. ftran, Jr. (6) Coulee D**or Aftet PlU No,____ iJ D. V. Moody, Jr. C. C. Seely J. H. Repp J. L. 81apeca DBQLXEZOS-PBSIGR CRITERIA SPIRITS-GRADE ETHANOL RSFISBKEKI ETHANOL PIAKT SO. 12 TEXAS CM, TEXAS Following are the recommended material and thickneaa specifications for each anticipated service condition: Temperature . Material Insulation Bervlce Range Specification Thlctoeae Proceaa - Piping and Equipment Procesa - Piping Proces* - Equipment Process Equipment - Subjected to Cyclic or Tbawovt Temps. Utility PlpU* (Steam, Water, Air, etc.) Utility Equipment (Steam, Water, Air, .etc.) Steam Traced Lines or Equip.^ Personnel Protection - Piping Personnel Protection - Equipment Above 50'? Belov 50*? Belov 50*F Belov 50*? normal (up to too*? thawout) 50*? to 250*? 1 50*? to 250*? .!*<*> 1M 1M-B TIM-101-515 TIM-HI-515 TIM-in-515 TIM-111-515 -* * 3A*': t , .4 * * 7K^3) All temperaturea TIM-101-515 135*? to 250^? 135*? to 250*? 7&3> UCCTXC 06221 2 8ervlce Temperature Range Personnel Protection - Piping 250*? and above or Squipnent Material Specifications 2A^ Insulation Thickness HX-lte-515 fire Protection - Piping and Equipment fire Protection - Piping fire Protection - -Equipment Kate* Above 50*? 50*? and below 50*? and below ltA^ 01 EW-133-515 T3M-13^515 TDt-13^515 (1) ALL valves, fittings sod other irregular surfaces shall receive a asstic weather barrier. \# --*r- (2) Aluminum Jacketing used in services operating helcw SO*? shell have a hahed-on acrylic enamel finish on the outside to prevent condensation. (3) On smell. equipaant where spraying of urethane would he Impractical,. Material Specification 2M nay he vised. (k) ?or steea operating at U00*? or less, copper tracing shall he need.. Per steam operating above J*00*F, stainless steel tracing shall ho used. . Because of restrictive regulations imposed by the Occupational Safety and Bsalth Administration (OSHA), the Texas City Plant has adopted a policy stating that no new-asbestos-containing Insulations shall be installed on new installations. Material Specification 2A presently approves calcium silicate products which still contain asbestos fibers. By the time material procureaent is necessary, asbestos-free products will be readily available; there fore, the material for Specification 2A should be one of the following: Kayla 10-AF Tbexso-12 - Owens-Coming flberglms corp. - Johns-Manvllle Corporation I Sager Caltemp, 3^fpe KA - Pabco Industrial Products This criteria is being Issued for simultaneous revler and preparation-of Insulation and Baat Tracing Schedules. Any comments should be directed to UCCTXC 06222