Document EdRYXYOJMGxR8kaRk5NMpGOwb

PLAINTIFFS EXHIBIT NO. 4 Intra-company correspondence K. 0. Preston - Bloomington from Gerald E. Oevltt Toledo 11 date October 13, 1970 \ *ubict CHEVfBEST RESPIRATOR PROGRAM ec: H. F. Janecck - Bloomington J. L. Konzen, M.D* - Toledo 11 F. O'N. Brisley - Toledo 12 J. J* Young Toledo 12 Attached is a copy of the suggested respirator program. As I'm sure you are. aware, ve look upon this as a temporary measure until positive engineering and process controls can be Installed. If there are any questions, or ve can further assist you, do not hesitate to contact us. Gerald E. Devitt Chief Industrial Hygienist GED/dsl Attachment 01 070 0217 respirator program BLOOMINGTON PLANT Tour respirator program Is fundament ally divided into two areas because of the types of exposure against vhieh you are protecting your employees* The urethane operation "vest of the tracks" is to be protected against by the use of "nusianee" type respirators, of which you have already received samples. Although these units are advertised as "single service", many firms use them for longer periods of time, and the dust exposures in these areas of your plant should permit this activity. Es sentially, we are suggesting that these units be Issued on a "as needed" basis, and several days service should be gotten from them. This should aid the cost picture greatly. It must be pointed out that these 3M masks are essentially useless against toxic materials, such as asbestos, and therefore their use must be confined to protection against nuisance dust, such as those found in the foam area. The program in the foam ares should basically consist of informing the supervisors and employees as to the need for the use of these respirators until such time as the proper engineering controls can be installed. Then once this respirator program is installed, enforcement ehould be done by the line supervisors. Employees resistance towards these masks should be minimal as the masks are light, relatively comfortable, and easy to breathe through. Since these units are disposable, maintenance is essentially non-existence. The respirators and program for **ee i the asbestos operation is more complex than those for the foam program, .t is necessary that the employees using these units be both Informed and impressed with the need for the proper use and maintenance of these respirators. Before each day's use, the rubber parts, such as the elastic straps, should be checked to see that they are pliable and in good condition. The valve of the respirator should be examined and the entire unit should be tested for tightness. Filters should be examined and replaced as necessary. In making a decision as to the need for the replacement of filters, the amount of resistance to breathing through the device when it is actually put on in normal air is probably the best indication of all. Mechanical filters such as those in the Dustflo respirator recomended that do not offer excessive resistance to air flow, and are obviously lntaet may be considered to at least retain their original efficiency, and in some cases to have improved, and therefore do not need replacing. Each day as the respirator is used by the individual ei^loyee to whom 4t has been assigned, the unit where it contacts the face should be washed vl^h warm water and soap. If sueh a used unit is to be reissued to another e^loyee then it should be sterilized/ Several commercially available solutions are available for this purpose. However, care must be exercised that the sterilizing or disinfecting solution ehoosen does not damage any parts of the respirator. It should be pointed out to the esg>loyee when he is first Issued this respirator, that in order to be effective in its protective capacity, the unit must be worn tightly fitted against the face. They should be informed that if the respirator fits too loosely and air gaps are allowed to exist, then this * RESPIRATOR PROGRAM - BLOOMINGTON PLANT -2- respirator will actually Increase the hazard to the employee aa it will trap tone of the asbestos fibers and almost insure that they will -ultimately be inhaled by the worker* Ve would also suggest that one member of plant supervision or manage ment be held responsible for the basic operation and Issuance of these respirators. As part of this duty the respirator supervisor should eee that each employee who has been issued such a unit* is given a clean, dry location which Is relatively dust free and not in direct sunlight for the storage of the individual'4 respirator. Also each employee should be is sued his own respirator, and by the same token he should be held accountable for this unit as long as working in operations vhleh require respiratory protection* Certainly, part of this respirator program is the instruction to the wearer to insure that he is aware of the purpose, use and care of this personal protective equipment which has been Issued to him, and the fact that he has a real responsibility for his own good to maintain this unit in good and operable condition. Additional aid for such a respirator program should be forthcoming from the supplier of these units. By the same token, if Medical Services can further assist you, ve would be happy to do so. 10/13/70