Document EdEbM8RQqb7QxBeJr65D5N7j
St. Louis, Missouri 63166 MCNS 062843
The thermal and chemical stability of the polychlorin
ated biphenyls (PCBs) are clearly responsible for their
widespread use in the electrical industry. Unfortun
ately, many of the environmental concerns about PCBs
are attributable to the same properties. Where fire
resistance and ef f 1 cl ent transmi ss 1 on of electrical
energy are Important, PCBs are the preferred dielectric
fluid. In fact, the U.S..Government's Interdepartment
al Task Force on PCBs, PCBS IN THE ENVIRONMENT (1972),
concluded that for closed'systems such as transformers
and capacitors there are no suitable replacement
products for PCBs. Consistent with these decisions,
Monsanto Introduced a new product, Aroclor* 1016,
containing substantially less of the degradation
vr.es1stant higher chlorinated Isomers, restricted the
sales to use In ol-ee-frd- ays terns, and set up a high
temperature 1 ncl ncerator <for ift^'dlsposal of used fluids. *
While incineration Is an icceptable solution to the
,J
disposal of used transformer fluids, It is not feasible*-
for tile disposal of PCB Impregnated capacitors.-wha-clv
..
*re--1n many_cases buried-in landfills-.-
The objective of this study was to produce data which would help evaluate the suitability of landfill disposal of Aroclor 1016 Impregnated capacitors. Of prime concern was the rate at which percolating ground water might leach Aroclor 1016 from various types of
soils.
Experimental
The experimental procedure employed consisted of perco
lating water through a column packed with soil coated with Aroclor 1016 and then monitoring the effluent
water for PCBs. The set up used Is shown schematically In Figure I. The soil columns employed are approxi mately 3" In diameter by 12" in height and were dry
packed In layers. Each soil layer being 3" thick first uncoated soil, followed by soil coated with 2.5% (w/w) of Aroclor 1016, and finally another layer of uncoated soil. An acetone solution of Aroclor 1016 was used to coat the air dried soil, followed by removal of the acetone In a rotary evaporator.
^Registered trademark of Monsanto Company
MQNS 062848
/ J.
Crfyi'jj/titr* 'SkkZ* Mjc -/ >i?u 'S"/, ^y
Three different types/of soils were used In this
ustudy. The characteristics of each are shown be-l-ow. >w
x
Soil
Norfolk
Ray
Drummer
Sandy Loam Silty Loam Silty Clay Loam
* Sand
* Silt
* Clay % Organic
Carbon
82.5 11.0
5.5
1.0
.
6.2 83.2
9.6
1.0
2.8 55.4 35.8
6.0
~'
_T.he i.ntent was to a/U-pvp-^KP /im(tarie th. e various soil types
which could be encountered at different land fill
sites. The soils used and the procedure employed -
have been used to evaluate the soil mobility of agri
cultural chemicals.
^ 7, Af/s Distilled water was/fed from the reservoir to -the soil
column [at a constant pressure The flow rates were
observed to increase the first few days, and then
decrease and level out. Apparently, after the wetting
phase some channeling occurs until the soil becomes
compressed In the column. This effect was most
pronounced with the silty soils. The average flow
rates in liters/day for Norfolk Sandy Loam, Ray Silty
Loam and Drummer Silty Clay were 0.26, 0.53 and 0.32,
respectively.
pOBs
The effluent water from the soiycolumn was In turn passed through a polyurethane/Toam column which quantitatively absorbs -thV'Wss? GESSER (1971).
Sampling was carried out on a periodic basis by
Interchanging a new polyurethane foam column for the old column. In this manner, the effluent couldj,*-- ^w*****'''
continuously monitored. The PCBs were r-Ame-re^trom the polyurethane by elution with 20 ml of acetone followed by 100 ml of nanograde hexane and collected In a 250 ml separatory funnel. The aqueous phase was discarded and the hexane layer was filtered through
anhydrous sodium sulfate Into a Kunderna-Danish evaporative concentrator. The hexane concentrate was transferred to an alumina* column and eluted with 125
ml of hexane. The hexane eluent was concentrated in
J
Alumina, chromatographic grade, 80/200 mesh, heated at 400C for 4 hours and deactivated with 5* (w/w) dis tilled water. 30g of alumina packed into a glass 'bViWliiotjUfl'^column 10" X 20 mm O.D. topped with 2 cm of anhydrous sodium sulfate and washed with 75 ml of nanograde hexane before addition of sample.
MGNS 062849
a Kunderna-Danish evaporative concentrator and analyzed using a gas chromatograph equipped with a electron capture detector. The conditions for the gas chromato graphic analysis were as follows:
Instrument: Hewlett-Packard Model 5753A
--
(Ni-63 Electron Capture Detector)
Column: 2M X +M-" 4* XE-60 silicone on 80/100 Mesh Chromosorb W High Performance - Glass
Injection Port Temperature: 220C Column Temperature: 170C isothermal Detector Temperature: 300*0
Carrier Gas: Helium, 60 ml/min. Purge Gas: 10* Methane/Argon, 120 ml/min. Pulse Internal : 50 nsec
.
,iResults and Discussion T Iwiv .L Xj.' O^r--
.
The -atHrl-y t-i-ca-1 columns were changed and analyzed on days
5, 10, 17, 24, 31, 39, 52, 98 and 185. Table JTsummar-
Izes the -el>*e^at-+otrs of PCBs In the column effluents >y\.
Qsu>slU
s FCt U-I'W
_____ Table in
Elapsed Days/
Norfolk
Ray
Drummer
Soil
Sandy Loam Silty loam S11ty Clay Loam
pp>t?,
5 thru 31 39 52 98
185
NO* ND* ND^ 65 23 92 63 153 63 136
NO ND ND ND ND
3~-#<me^ete4d_-*4-ppb f
' pfb
Breakthrough of the PCBs In the effluent water was
related to the clay content of the soil. The soils
containing higher levels of clay retained the PCBs.
The order in which breakthrough occurred as a function
of effluent volume was Norfolk Sandy Loam followed by
Ray Silty Loam and finally Drummer Silty Clay Loam
(none observed). This Is in agreement with recent work,
HAQUE (T 97 4 ) , demonstrating that iMtf clay^ -ar-e -good-
,
adsonbetrty for PCBs.
** h-fluo 0^ *Cz<. !'u
HONS 062850
fas'loO
yu**-pr-
ks*.
_
b'The the
water
solubility
of
Aroclor
1016
has
not been' determi ned;1 i t Is estimated p> be In the
range of 225-250 ppb. The -ba-e-H--F*r-th1s estimate Is
. j_/ . q tiU
that Aroclor 1016 contains more of the less chlorln-
4-'^
ated, more, soluble Isomers than does Aroclor 1242 which has'a water solubility of 200 ppb. In all cases, the.^oncentratlon of PCBs In the effluent water was less ^than the estimated solubility of Aroclor 1016 In water, f
, Ir
CJ'M.-'-! The chromatograms shown In Figure II detail the Isomer
distribution of the PCBs observed in the effluent water. Aroclor 1242, the product formerly sold for use in capacltors, 1 s shown at the top. '"(he Aroclor 1016 which
was coated on the soil Is shown next,fol1 owed by the PCBs leached from the soils, and finally a less chlorin
ated member of the Aroclor series, Aroclor'1221, which was used as a standard for quantitation. The number '
above each peak Indicates the v4pm4fiate)chioroblphenyl In that peak. A comparison of th'e Aroclor 1 242 and ' ' Aroclor 1016 chromatograms i nd I lj tffS the -4-gn1 f 1 eent
reduction of the penta and higher chloroblphenyls achieved In the manufacture of Aroclor 1016.
aV-o
The Isomer distribution of the PCBs in the effluent water is the result of differences In the water solubility and adsorption characteristics of the
Isomers In Aroclor 1016. It is evident that only the less chlorinated, more biodegradable PCBs, AHMED and FOCHT (1973 a,b),TUCKER (1972), similar to Aroclor
1221, were leached from the soil. A degradation rate for Aroclor 1221 of 73+21J has been observed In semicontinuous activated sTudge tests at feed levels of 1 and 5 mgs/24 hours^ TUCKER (1972).
Conclusions
The results of this study clearly demonstrate that PCBs are not readily leached from soil by percolating water.
In the worst case, less than 0.05X of the total Aroclor 1016 available (25,000 ppm) was leached from the soil
during the entire four month duration of these experi ments. During this period of time approximately 30-70 liters of water were passed through the three soil
columns, an amount of water roughly equivalent to 30 50 ft. of rainfall, assuming no run off.
The ease of leaching Aroclor 1016 from the different types of soils was in the following order: Norfolk
Sandy loam>Ray Silty Loam>Drummer Silty Clay.
MCNS 062851
XOAI.S 06i85i
MGNS 062853