Document Ed6OEZYz1ZpJeB72ZXQeeOeDR
American Society of Heating and Ventilating Engineers Guide, 1926-27
is so small that the least unfavorable condition or interference practically puts the chimney out of commission.
At best the head produced by chimneys up to 64 ft. in height is so. small that the draft is frequently affected by surrounding conditions making the draft a doubtful one. 'Chimneys over 64 ft. in height are not usually so affected, because as a rule the chimney is designed by an engineer and must be well built to sustain such a heavy load and the
height is such as to produce considerable head or force to offset unfavor
able weather conditions, etc. Chimneys in this class produce about
0.009 in. draft per ft. of height in zero weather with 600 deg. in the stack
according to the formula:
)P
7.9
r8
where
P = draft pressure in inches of water.
H = height of chimney in feet.
T0 = absolute temperature of outside air.
Ts = absolute temperature of stack gases.
For low-pressure heating boilers, water heaters and warm air furnaces conservative modern practice in the matter of chimney sizes is in accord ance with the accompanying schedule, Table 61 :
Table 61. Chimney Sizes
Warm Air
Furnace Capacity
in
Leader Pips
Sq. In.
Steam Boiler Capacity Sq. Ft.
of
Radia
tion
Hot Water Heater Capacity Sq. Ft.
of
Radia
tion
Nominal Dimen
sions
OF FireClay
Lining In.
Rectangular Flue
Actual
Inside Dimensions
of Fire Clay
Lining
In.
Actual Area
Sq. In.
Effec tive Area Sq. In.
Round Flue
Inside Diameter
of Lining
In.
Effec tive
Area Sq. In.
Height in Ft. from Grate
790 590 973 8Mxl3
7xllJ-<! 81 70
1000
690 1140
900 1490 13x13 llKxllK 127 99
900 1490 8Hxl8 6%xl6^ 110 100
1100 1820
1700 2800 13x18 HMxi6
183 156
1940 3200
2130 3520 18x18 15^x15% 248 195
2480 4090 20x20 17Kxl7k 298 234
3150 5200
4300 7100
4600 7590 20x24
17x21
357 278
5000 8250 24x24
21x21
441
5570 9190
24x24* 576 380
5580 9200
6980 11500
7270 12000
24x28* 672 468
8700 14400
28x28* 784 531
9380 15500
10150 16750
30x30* 900 616
10470 17250
28x32* 896 635
11800 19500
14700 24300
17900 29500
10
12 15
18 20
22 24
27
30 33 36
*Dimensions below are for unlined rectangular.flues. 1See also Code of Minimum Requirements for Heating and Ventilating of Buildings.
112
SJi
79 c o I-2
113 cr o
177 2 jo
o-q
52 254 c"w 314
5.2 |
c 41 u
380 aSt) 452 m2
b>2afa2
573
707 855 1018
g.Hx.
,, r =
&>
C'o-e
American Society of Heating and Ventilating Engineers Guide, 1926-27
Chimneys recommended for larger, boilers 15 to 250 .hp. are propor tioned in accordance with the report made by a joint Committee of the American Boiler Manufacturers Association and Stoker Manufacturers Association and approved by these organizations. The sizes are given in Table 62.
Table 62. Height of Stack for Average Installations (Sea Level) Forced Draft Stokers
Per Cent Rating.................................... Draft Furnace........................................ Friction Loss (Boiler)......... '................ Friction Loss (Breeching)................... Total Draft Required........................... Height of Stack (Ft.)...........................
100 0.15 0.18 0.10 0.43
80
150 0.15 0.4
0.10 0.65 112
200 0.15 0.65 0.10 0.90 145
250
0.15 0.9 0.10 1.15
178
300 0.15 1.20 0.10
1.45 220
^_ Diameter of Chimney in Inches for Horizontal Return Tubular Boilers
Height of Stack in Feet--For Sea Level and 0 deg. fahr. Outside Temp. Assumed Fric. jjon Loss in Stack 0.1 in. per 100 ft.
Nominal
H. P.
15 20 25 30 35 40 50 60 75 90 100 115 125 150 175 200 210 225 250
100% Rating
13 14 16 17 18 19 20 21 23 . 25 26 27 28 30 32 33 34 35 36
150% Rating
14 16 18 19 20 21 23 24 26 28 29 31 32 34 36 38 38 40 41
200% Rating
17 18 20 21 22 23 25 27 29 31 33 34 35 38 40 43 44 45 47
Draft at Base of Stack
0.12 0.15 0.20 0.25 0.30 0.35 0.40 0.45 0.50 0.55 0.60
_0._6_5 ___ ___ ___ ___ ___
--
100% Rating
21 26 35 43 52 60 69 78 86 95 104 112
__
__
150% Rating
22 ' 28
37 46 56 65 74 84 93 102 112
_12_1
200% Rating
25 30 41 51 61 71 81 91 101 111. 122 132
__
Rating............
Efficiency____ CO,.. ...........
Data on Which Tables are Based
100% 65% 8%
150% 200% 65% 63%.
9% 10%
Stack Temp, deg. fahr.................
Lbs. of Gas..................
450 -500 85 77
550 73
Average Friction Loss Through Boilers
Per Cent Ratings..........
100
150
200
250
300
Loss Ins., Water...... ....... 0.1 to0.3 0.2 to0.6 0.3 to0.9 0.5 to 1.4 0.7 to 1.9
Friction loss through boiler varies according to construction. -- -- For Furnace Draft.--Allow 0.15 for forced draft. For Natural Draft 0.35 iri. or higher should be used depending upon rate of combustion and fuel used. For Breeching Friction Loss.--Allow 0.05 in. for each right angle bend and 0.1 in. per 100 ft. of length. Cross sectional area should be 20 per cent larger than that of stack.
113