Document Ed1GZaNyyzEeaQ5MjvxVow7pb

42-*tlZ/ SELECTOR PYDRAUL Fire-Resistant Hydraulic Fluid A guide to selecting the cor rect Pydraul fluid for hydraulic systems. O/FF-3 Monsanto TOWOLDMONOQ35369 TOWOLDMONOQ35370 PYDHAUL. fluids Development Fire protection for industrial hydraulic opera tions began with Pydraul in 1951. Pydraul fluids have since provided industry with millions of machine hours of safe operation. Pydraul fluid has never caused a fire--not even when sprayed from broken high pressure hydraulic lines onto white-hot surfaces. New ways are continuously being explored to improve the excellent performance records of Pydraul fluids. From the first Pydraul fluid, (Pydraul F-9) the family has grown to a dozenplus specially tailored, fire-resistant safety fluids. Each answers a major but specific hy draulic fluid need for industrial use. In addi tion to guarding Against fire, each Pydraul fluid lubricates as well as premium grade oil. Pydraul fluids have answered the need of vir tually every industrial hydraulic operation, in doors and out--from the sub-zero, outdoor hy draulic lift operations for refineries and blast furnaces to the low-viscosity fluid demands of high-speed, precision machine tools. REFORMULATION The Pydraul fluids in this Selector were re formulated in 1970 to remove polychlorinated biphenyls (PCB's). They are now designated with the letter "A" following the product name and provide equal or superior performance when compared to the original Pydraul fluids. Because some PCB's have been considered to be persistent in the environment, Monsanto chose to remove these components from Pydraul. We took this action voluntarily in an effort to demonstrate our environmental awareness. Reformulation of the Pydraul fluids provided us with the opportunity to make a number of product improvements, particularly in the areas of lubricity, pump performance and thermal stability. These improvements give you the benefit of the latest Monsanto technology in fire resistant hydraulic fluids. Performance Pydraul fluids offer a wide range of viscosities from which you can select the proper range speci fied by your hydraulic equipment manufacturer. Whichever Pydraul fluid you select, each pro vides the same protection against fire, premium lubricity, ease of maintenance, and freedom from corrosive action and foam. Pydraul hydraulic fluids also offer several additional benefits-- REDUCED FIRE INSURANCE RATES Pydraul eliminates fire hazards from hydraulic 'operations, reduces fire threats to surrounding structure and equipment. Insurance premiums for plants using Pydraul are often lower than premiums for operations using petroleum oil. LONGER PUMP LIFE Machines which operate on water-based fluids frequently require pump repair or replacement as often as every two or three months. Machines which use Pydraul hydraulic fluids can operate on the same pump for several years. Pydraul hydraulic fluids give the same long pump life as the finest grade petroleum oil. NO CORROSION PROBLEMS Any metal hydraulic system component in con tact with Pydraul will not rust. Pydraul hydrau lic fluids do not lose anti-rust properties even after extended use. MAXIMUM EQUIPMENT RESPONSE Pydraul never produces excessive froth or foam during normal operations to interfere with hy draulic equipment response. Because Pydraul hydraulic fluids lubricate as well as premium petroleum oils, Pydraul permits equipment to operate at optimum response capability. INSPECTION AND REPLACEMENT DOWN-TIME ARE VIRTUALLY ELIMINATED Pydraul hydraulic fluids are designed to be permanent. Pydraul fluids do not wear out. Ex cept for normal "make-up" requirements, you never have to add new Pydraul to hydraulic systems. Pydraul eliminates "drain and change" periods; it does not have to be inspected in your system from month to month--or replaced from year to year. 0bi0178 1 TOWOLDMONOQ35371 PYDHAUL Selector One PHYSICAL PROPERTIES Appearance Spec. Gravity 25/25C. Neutralization No. (mg KOH/g) man. Moisture (max.) % VISCOSITY Centisfokes(n iOOT. (a 2109F. SSU (o 100F. (a 210F. Absolute SSU (<i 100F. (SSU x Density) ( 210F. Pour Point Bulk Temp. Max. (continuous operation) Boiling Point eF. at 760 mm Hg Coefficient of Thermal Expansion per F. Specific Heat BTU/lb./'T. ( 77F. Thermal Conductivity BTU/hr./ft./F. Vapor Pressure mm Hg(n 200F. Bulk Modulus (Room Temp. 1000-6000 psi) Rust Test ASTM D-665 Foam Test ASTMD-892 Solubility in Water . FIRE RESISTANCE TESTS Factory Mutual Spray Test. Test fluid sprayed at 1000 psi through orifice, passing through flame of propane torch. Factory Mutual Channel Iron Test. Test fluid sprayed at 1000 psi through orifice, onto hot channel iron at 1300F. Hot Manifold Test (Federal Test Method Std. 791). Test fluid dripped on at 1300F. ^ Factory Mutual Apprcn^l. FM.) ( FM J PYDRAUL 60 Cloudy Blue Liquid 1.088-1.091 0.25 0.10 9.6--10.4 cs 2.3--2.5 cs 60 SSU 35 SSU 60.5 SSU 35 SSU --70F. 17 5F. 707F. 0.00044 0.42 0.047 0.002 328,000 Pass Pass Negligible Pass Pass Intermitlenl flashing and burning. Does not burn after leaving tube. Yes Fire-resistance Advantages of Pydraul Pydraul fluids protect hydraulic equipment and person nel with permanent fire protection. Pydraul fluids contain no water to evaporate and leave a flammable residue. During their millions of hours of machine use, Pydraul fluids have been accidentally sprayed over molten metal, through electrical arcs, into flames and sparks--without causing fire. Pydraul fluids have never caused or con tributed to a hydraulic fire in any type of equipment. They pass all of the important ignition tests for fireresistance. FOLLOWING IS A PARTIAL LIST OF APPLICATIONS FOR THE PYDRAUL FLUIDS: STEEL INDUSTRY continuous casters rolling mills furnaces scrap chargers stripper cranes arc welders combustion controls mobile equipment 0510179 2 TOWOLDMONOQ35372 PYDRAUL 150-A Cloudy Blue Liquid 1.120-1.131 0.30 0.10 29-34 cs 6.9-8.1 cs 146 SSU 53 SSU 163 SSU 56 SSU --55F. 150F. 585F. 0.00042 . 0.40 0.072 0.01 319,000 Pass Pass Negligible PYDRAUL F-9-A. Clear Blue Liquid 1.20-1.23 0.50 0.10 48-57 cs 4.7--5.5 cs 250 SSU 43 SSU 302 SSU 52.2 SSU 0F. 225F. 644t>F. 0.00037 0.34 0.065 0.02 395,000 Pass Pass Negligible ' Pass Pass Inteimittent flashing and burning. Little burning in pan below. Yes Pass Pass Does not flash or burn. Yes PYDRAUL 625-A Clear Blue Liquid 1.30-1.34 0.50 0.10 125-145 cs 6.7--7.2 cs 628 SSU 49 SSU 829 SSU 65 SSU + 5F. 225F. 770F. 0.00048 0.30 0.062 0.004 400,000 Pass Pass Negligible Pass Pass Does not flash or burn. Yes ALUMINUM INDUSTRY stripper cranes direct chill casters furnaces rolling mills mobile equipment FORGING AND EXTRUSION forge presses extrusion presses ^ billet manipulators FOUNDRIES furnaces molding lines 3 DIECASTING diecast machines trim presses FABRICATION forming presses welders furnaces 0510180 TOWOLDMONOQ35373 TOWOLDMON0035374 VISCOSITY, SAYBOLT UNIVERSAL SECONDS VISCOSITY, SAYBOLT UNIVERSAL SECONDS O -100 -90 --70 -60 -50 -- *0 - 30 -20 -10 0 10 20 30 *0 50 60 70 SO KINEMATIC VISCOSITY, CENTISTOKES KINEMATIC VISCOSITY, CENTISTOKES V TOWOLDMONOQ35375 i/> * < 2S! *- O | Mixing Compatibility PYDRAUL WITH OTHER HYDRAULIC FLUIDS ` ....... | 60 I 1M-A ] F-9-A j * rROUti LLLLl. 90 YES NO YES YES 150 YES NO YES YES 220 YES NO YES YES 300 YES NO YES YES 550 YES 1 NO 1 YES YES HOUGHTO-SAFE 1010 1055 1 1120 1130 YES YES YES"" YES NO NO NO " NO YES YES YES y'es "1 YES YES YES YES Fyrquel is a registered trademark of Stauffer Chemical Company. Houghto Safe is a registered trademark of . F. Houghton Co. PYDRAUL WITH OTHER PYDRAUL FLUIDS 135-A 230-A 312-A 540-B 60 150-A F-9-A 625-A 60 150-A F-9-A 625-A YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES - NO YES YES NO - NO NO YES NO - YES YES NO YES - NOTE: All of the reformulated Pydraul fluids are compatible with their older counter part i.e. 150-A is compatible with 150, F-9A with F-9, etc. 0310163 TOWOLDMONOQ35376 Converting to PYDRAUL is Easy Regardless of the type hydraulic fluid being used, converting a system to low-cost Pydraul fluids is easy. Virtually every type of equipment which uses fire-resistant hydraulic fluid has been converted to Pydraul fluids. Most equip ment manufacturers are experienced in Pydraul fluid conversions and should be consulted. If changing seals is necessary, equipment manu facturers can recommend what seals to change, and many carry a supply of correct seals. Laboratory tests and operational experience show Viton*, Teflon*, and silicone the preferred elastomers for compatible seals. Please refer to the following section on seal and packing in formation for compatibility of Pydraul with other elastomers. To replace other fluids which are compatible with Pydraul and where compatible seals are in the system, it is only necessary to add Pydraul as make-up fluid. It is not necessary to drain or clean. When converting from petroleum oils, non-compatible synthetic fluids, water-glycol fluids, or water-in-oil emulsions, the following steps are recommended. These conform to USA Standard R93.5--1966. Please ask the Monsanto fluids specialist for recommendations and assistance. He may be reached by phoning the nearest sales office, listed on the inside back cover of this brochure* Change-Over Procedures CHANGING FROM PETROLEUM OIL 1. Completely drain and clean the system. Small amounts of oil will not interfere with the per formance of Pydraul, but resistance to fire is reduced by the amount of oil left in the system. 2. Drain and blow out pipelines. Manually clean valves and reservoirs. 'Registered trademark of EL. I. Du Pont de Nemours & Co., tnc. 3. Open' or remove and drain valves. Replace gaskets, packings, and seals with those com patible with Pydraul. It is particularly im portant to change dynamic seals. Static seals do not necessarily have to be changed if they are not leaking. Non-compatible static seals will have to be replaced when the part is disassembled for maintenance. 4. Remove pumps, accumulators, and cylinders, if necessary, for draining. Replace packings, seals, gaskets, and bladders with those com patible with Pydraul. 5. Check component functions before the sys tem is closed and fluid is added. 6. If your system cannot be completely drained, you may have to flush it with a small amount of Pydraul. CHANGING FROM WATER-GLYCOL OR WATER-IN-OIL EMULSION 1. Drain and clean system thoroughly. Remove all traces of water. Empty all lines and low points or dead pockets in components. 2. Clean with steam or warm water. Follow by blowing with dry air. 3. Check sealing materials, hoses, and accumu lator bags. Replace if necessary with com patible materials. 4. Install a minimum charge of Pydraul and operate the system from 16 to 24 hours. During this period, inspect the reservoir. If water or other contaminants float to the top, skim them off. 5. Drain the flushing charge immediately after shut-down while the fluid is warm. Drain all isolated points or parts which do not drain back to the reservoir. If water is apparent in fluid clinging to walls, wipe down all acces sible parts. CHANGING FROM PHOSPHATE ESTERS (OTHER THAN PYDRAUL) 1. Drain the system completely. 2. Cleaning is unnecessary. 3. Generally, seal changes are unnecessary at the time of conversion, but installation of compatible seals is recommended during routine maintenance. i 0510184 TOWOLDMONOQ35377 Seals and Packings Information Materials compatible with Pydraul hydraulic fluid are necessary for dynamic or moving seals. For static seals they are preferred, but not essential. The following table indicates materials recommended, de pending on the Pydraul fluid selected. PYDRAUL FLUID 60 F-9-A 150-A 625-A BUTYL R R R R R--Recommended EPR VITON TEFLON SILICONE BUNA N NEOPRENE NATURAL RUBBER Russu u u RRRRu u u RRRRu u u RRRRu u u S--Satisfactory M--Marginal U--Unsatisfactory This list of component manufacturers is a guide to obtaining seals compatible with Pydraul fluids. Please contact your equipment manufacturer or seal supplier for their most current recommendations. Acushnet Process Company 776 Belleville Avenue New Bedford, Massachusetts 02745 Anchor Packing Company 401 North Broad Street Philadelphia, Pennsylvania 19108 Bearings, Inc. 3634 Euclid Avenue Cleveland, Ohio 44115 A. W. Chesterton Company Everett Massachusetts 02149 Chicago Rawhide Manufacturing Company 1311 Elston Avenue Chicago, Illinois 60622 C. E. Conover & Company, Inc. 333 Passaic Avenue Fairfield, New Jersey 07006 Crane Packing Company 6400 Dakton Street Morton Grove, Illinois 60053 Garlock Packing Company Palmyra New York 14522 Goshen Rubber Company, Inc. P. 0. Box 416 Goshen, Indiana 46526 Greene, Tweed & Company North Wales Pennsylvania 19454 Hercules Packing Corporation 11061 Walden Road Alden, New York 14004 International Packing Corporation Bristol New Hampshire 03104 Johns-Manville 22 East 40th Street New York, New York 10016 C. W, Marsh Company 36 Hudson Street Mu9kegon, Michigan 49441 Minnesota Rubber Company 3630 Wooddale Avenue Minneapolis, Minnesota 55416 Parker Seal Company 10567 Jefferson Boulevard Culver City, California 90230 Plastic & Rubber Engineering, Inc. 756 East Florence Avenue Los Angeles, California 90001 Plastic & Rubber Products Company 2100 Hyde Park Boulevard Los Angeles, California 90047 Precision Rubber Products Corporation Hartmann Drive Lebanon, Tennessee 37087 Raybestos-Manhattan, Inc, Packing Division Passaic, New Jersey Reliable Rubber Products EddyingTon Pennsylvania 19020 Rockwell Mechanical Packing Company. Inc. 1634 Long Beach Avenue Los Angeles. California 90021 W. S. Shambari Company 11617 West Jefferson Boulevard Culver City, California 90230 Vellumoid Company Rockdale Street and Beaman Avenue Worchester, Massachusetts 01606 The James Walker Packing Company, Inc. P. 0. Box 75 Chicago Heights, Illinois 60411 OblOlbb 8 TOWOLDMON0035378 Filters and Hoses FILTERS/Most standard oil filters are satisfactory. You can use active earth or clay types. Filter manufacturers include: Briggs Filtration Division Bowser Corporation Cookeville, Tennessee Dollinger Corporation 20 Centre Park Rochester 3, New York Capital Engineering Company 5839 Ashland Avenue Chicago, Illinois Commercial Filters Corporation (HonanCrane) Lebanon, Indiana Cuno Engineering Corporation Sub. of American Machine & Foundry 4627 S. Vine Street Meriden, Connecticut Fulflo Specialties Company, Inc. 410 Fancy Avenue Blanchester, Ohio Hilliard Corporation 98 W. Fourth Street Elmira, New York Marvel Engineering Company 7227 North Hamlin Avenue Chicago 45, Illinois Pall Corporation 32 Sea Cliff Avenue Glen Cove, L. I., New York Purolator Products 1000 New Brunswick Avenue Rahway, New Jersey Rosaen Filter Corporation 1776 E. Nine Mile Road Hazel Park, Michigan Schroeder Bros. Corporation 101 Nichol Avenue McKees Rocks, Pennsylvania Serfilco Division Service Filtration Corporation 7408 North Milwaukee Niles, Illinois 60648 HOSES/Although both neoprene and buna elastomers swell some what in Pydraul, hose of these materials have given satisfactory service when made of a reinforced braid construction. Butyl, nylon or Vi ton are preferred when new hoses are installed. Suppliers include: Anaconda Metal Hose Division Anaconda American Brass Co. Waterbury, Connecticut 06720 Anchor Coupling Company 3600 N. Fourth Street Libertyville, Illinois Eastman Mfg. Company (See Imperial-Eastman Corp.) Department T. R. 6300 West Howard Street Chicago 48, Illinois Electric Hose & Rubber Co. 1201 Duro Street Wilmington, Delaware Gates Rubber Company 999 South Broadway Denver, Colorado 80217 Imperial Eastman Corp. 6300 W. Howard Street Chicago, Illinois Lewis Products Hohenwald, Tennessee 38462 Samuel Moore Co. Mantua, Ohio Resistoflex Corp. Roseland, New Jersey Stratoflex, Inc. 222 Roberts Cutoff Rd. Fort Worth, Texas Weatherhead Corp. 302 E. 131st Street Cleveland, Ohio 44108 TOWOLDMONOQ35379 Other Components SWIVEL COUPLINGS Systems for Pydraul fluids often contain swivel couplings. Some suppliers are: Chiksan Division FMC Corporation 332 N. Brea Boulevard Brea, California PIPE JOINT SEALERS . . . can be bought from: American Sealants Company (See Loctite Corporation) 115 N, Mountain Road Hartford 11, Connecticut Crane Packing Company 6410 Oakton Street Morton Grove, Illinois Dow Corning Corporation Midland, Michigan Friesland Plastics Company Friesland, Wisconsin General Electric Company Insulating Materials Department 1 Campbell Road Schenectady 6, New York Permatex Company Department T. R. Flagler Court Building West Palm Beach, Florida W. S. Shamban & Company 11617 W. Jefferson Boulevard Culver City, California Shell Chemical Company 110W. 51st Street New York, New York PAINTS . . . resistant to Pydraul are supplied by: ,, Amercoat Corporation Department T Brea, California Andrew Brown Paint Company 5413 S. District Boulevard Los Angeles, California Carboline Company 32-R Hanley Industrial Court St. Louis, Missouri Carrol Products 148 Marine Street Farmingdale, New York Finch Paint & Chemical Company Torrence, California W. P. Fuller & Company 1645 W. Valencia Drive Fullerton, California The Glidden Company 900 Union Commerce Building Cleveland, Ohio Interchemical Corporation Finishes Division 1255-T Broad Street Clifton, New Jersey Lowe Brothers Company Third & Madison Streets Dayton, Ohio Magna Coatings & Chemical Corporation 1785 N. Eastern Avenue Los Angeles, California Nycote Laboratories 15002 Delano Street Van Nuys, California Pittsburgh Plate Glass Company One Gateway Center Pittsburgh 22, Pennsylvania Rinshed-Mason Company 5935 Milford Detroit, Michigan Royalty Paint & Varnish Company Pasadena, California Saran Protective Coatings Company 2415 Burdette at Reed Ferndale, Michigan Sherwin-Williams Company 101 Prospect Avenue, N. W. Cleveland, Ohio Titanine, Inc. Seagrave Corporation Elmwood & Morris Avenues Union, New Jersey U. S. Paint, Lacquer & Chemical Company 2101 Singleton St. Louis, Missouri ACCUMULATORS . . . many hydraulic systems for Pydraul contain an accumulator which uses a bladder to separate the fluid from air or nitrogen pressure. For these, a rubber compatible with the fluid is nec essary. Suppliers include: Greer Hydraulics. Inc. 5930 W. Jefferson Boulevard Los Angeles, California TOWOLDMON0035380 Reclaiming PYDRAUL Fluids Pydraul hydraulic fluid lost from leaks and spills caii be reclaimed because it is exceptionally stable and resistant to water and other con taminates. If fluid losses are appreciable--fluid recovery can result in considerable savings. Simply placing a container beneath leaks until they can be repaired will save some fluid. Where drip pans have been used beneath hydraulic WATER REMOVAL... Water does not mix with Pydraul and will, therefore, form a layer on top. A drum reserved for contaminated fluid with a side and end bung, placed horizontally on a cradle about two feel off the floor, is a simple machinery, more than half of the total Pydraul leakage has been reclaimed. This dollar-saving recovery appears especially advantageous because it isn't practical to re claim either water glycol or water-oil emulsions except to filter out large dirt particles. Re claiming Pydraul fluid helps make it the most economical fire-resistant fluid available. Reclaiming Pydraul consists of two steps: re moving water, and filtering dirt or other solid particles. and effective settling chamber. Salvaged fluid can be added through a large funnel in the top opening and Pydraul periodically drained o(T through the lower opening. For a more elaborate system, permanently in stalled set tling tanks, or a commercial installa tion can be used. A second method is centrifuging. Suitable units arc* made by DeLaval and Sharpies Co. Cen trifuges operate swiftly . . . will separate water from large volumes of fluid in a short time. FINAL FILTRATION ... A number of filtration units are available complete with filter pump and motor. Other systems use filler media such as cotton linters, felt or metal screens. Attapulgus clay and Fuller's earth may be used to help keep the fluid clean, reduce moisture and lower neutralization number. Diatomaceous earth filtration is recommended for solid parti cles removal only. Paper and fiber type filters are recommended for water and particle re moval but are ineffective for lowering neutra lization number (acidity) values. n Handling Animal toxicity studies and human experience indicate that the Pydraul hydraulic fluids may be used safely if a few reasonable precautions are taken. Repeated or prolonged skin contact should be avoided not only to prevent absorp tion of the material and possible systemic effect but, also, because the fluids are excellent sol vents for the oils normally present in the skin. Thus, drying and irritation could occur. When splashed or sprayed into the eyes, Pydraul causes painful smarting. There is no evidence, however, of any permanent eye injury. In the event of accidental contact with the eyes, the eyes should be flushed with copious amounts of water for 15 minutes and the workman re ferred to a physician; physicians have used \</( Pontocaine solution and ophthalmic cortisone acetate solution to relieve irritation. When Pydraul is kept at room temperature, it does not constitute a vapor inhalation hazard except in a confined, unventilated space. Res piratory protection or mechanical exhaust ven tilation should be provided if there is repeated and prolonged contact of the fluid with heated surfaces with resulting volatilization or possible decomposition of the fluid. Where a ruptured oil hydraulic line near a white-hot surface means a fire, a ruptured hydraulic line containing Py draul causes a vapor with an unpleasant odor that can help you locate the trouble. 0310189 TOWOLDMONOQ35382 DISTRICT SALES OFFICES ALL DIVISIONS AKRON, OHIO 44313 260 Springside Drive Montrose Development Park Tel. (216)666-4111 AJLANTA, GEORGIA30326- /'''Lenox Towers East ( 3400 Peachtree Rd. N. E.--Suite 1711_^ VJej. (404) 577-220----------- 3*2-0 BOSTON, MASSACHUSETTS 02149 Everett Station Tel. (617)387-5010 CHICAGO, ILLINOIS 3158 Des Plaines Ave. Des Plaines. Illinois 60018 Tel. (312)296-6688 CINCINNATI, OHIO 45206 1501 Madison Road Tel. (513) 751-6707 DETROIT, MICHIGAN 48235 500 Northland Towers East Tel. (313)357-0910 HONOLULU, HAWAII 96812 205 Pacific International Bldg. 677 Ala Moana Blvd., P.O. Box 3824 Tel, (808) 531-2744 HOUSTON, TEXAS 77002 1300 Main Street Tel, (713) 223-4011 LOS ANGELES, CALIFORNIA 90022 6670 t. Flotilla St. Tel. (213) 723-2492 3,^,1-t f~r~1 For technical information phone your Monsanto representative or the nearest sales office (listed on this page). To place an order for Pydraul products from Monsanto Dial toll free 800-325-3850. NEW YORK, NEW YORK 10017 277 Park Avenue 'Tel. (212)922-4111 ST. LOUIS, MISSOURI 63166 800 N. Lindbergh Blvd. Tel. (314) 694-1000 SAN FRANCISCO BAY AREA 2710 Lafayette, Santa Clara, Calif. 95052 Tel. (408) 243-0414 SEATTLE, WASHINGTON 98104 911 Western Avenue Tel. (206)622-4203 SPRINGFIELD, MASSACHUSETTS 01101 730 Worcester Ave. Tel. (413)788-6911 WILMINGTON, DELAWARE 19803 2005 Concord Pike, Fairfax Tel. (302) 658-6531 "Nothing contained herein is to be construed as a recommendation to use any product in conflict with any patent M0NSAN10 MAKls NO WARRANTIES AS TO THI EUNfSS OR ME RCHANT Affli (T Y Of ANY PRODUCTS REFERRED TO. no guaiantee ol satisfactory results from reliance upon contained information or recommendations, and disclaims all liability for any resulting loss or damage " Monsanto Monsanto Company / Organic Division, Specialty Products f 800 North Lindbergh Blvd. / St. Louis, Missouri 63166 0610190 TOWOLDMONOQ35383 MONSANTO COMPANIES AND OFFICES Argentina Monsanto Argentina S.A.f.C. Tucuman 117 Buenos Aires El Salvador Netherlands , s,,,uMonsmloCmHoimmc, OT./o*; S.A Monmlc N V er/,t,,Z7lr r c,,,, Uc,, % -- Australia Adelaide Monsanto Australia Limited P.O. Box 1111K Adelaide South Australia 5001 Brisbane . ' San Salvador France Societe Monsanto 8, rue d Argenson . Paris 8me * Nicaragua Monsanto (Nicaragua) S.A. Apa'tado Postal 288 Managua Monsanto Australia Limited . P.O. Box 63, Hamilton Central Queensland 4007 Melbourne Monsanto Australia Limited Germany Monsanto (Deutschland) G.m.b.H. 3 Immermannstresse 4000 Dusseldorf 1 Pakistan Karachi Monsanto Overseas S.A. Dinshaw House Fiat D-3 Ho. 4 Bath Island Hill Bast Tower, Princes Gate 161 Flinders Street Perth Monsanto Australia Limited P.O. Box 90 Applecross . Karachi 4 Guatemala Lahore . Monsanto Centroamerica (Guatemala) S A 7a Avenida 11-89 Zona 9 ' Edificio Gaieties Espana Guatemala City Monsanto Overseas S.A P.O. Box No. 1226 Lahore 4 West Australia 6153 Sydney Monsanto Australia Limited P.O. Box 4 Rozel/e Hong Kong Monsanto Far East Limited Fifth Floor, New Henry House Ice House Street Philippines Monsanto Philippines Inc. Suite 314. Rufino Building 6784 Ayala Avenue Makati. Rizal, D-708 H.S.W. Australia 2039 Austria Monsanto G.m.b.H. Rudoffplatz 12 Wien 1 India Bombay Monsanto Chemicals of India Private Ltd. Wakefield House 11 Sprott Road, Ballard Estate Puerto Rico Monsanto Inter-America Co. P.0. Box 837 Halo Rey Station Halo Rey 00919 Belgium ' Monsanto Europe S.A. I, Place Madou Bombay 1 Calcutta Monsanto Chemicals of India Private Ltd. Singapore Monsanto Singapore Co. (Pte.) Ltd. Gainurn Building, 2nd Floor Brussels 3 Belgium /Luxembourg Monsanto Europe N.V. 163, Mechelsesteenweg Antwerp 1 Brazil ' 19 Bejendranath Mukherjee Road Calcutta 1 Madras Monsanto Chemicals of India Private Ltd Caithness Hall 310-311 Linghi Chetty Street Madras 1 241 River Valley Road Singapore 9 South Africa Monsanto South Africa (Ply.) Ltd. 85 Russik Street Johannesburg Monsanto Comercio e Industrie Ltda Rua Araujo 216. 6' Andar Seo Peulo Canada Montreal New Delhi Monsanto Chemicals of India Private Ltd. 3/8 Asaf AH Road Hear Turkman Cate Spain Monsanto Iberica, S.A. Leparto 350 Barcelona 53 Monsanto Canada Limited Suite 1450 Place de Canada Israel Israel Chemical Fibres Limited Industrial Zone Sweden Monsanto (Scandinavia) AB Montreal 101 Ashdod U/vsundavaegen 108 Edmonton Monsanto Canada Limited P.O. Box 416 Edmonton, Alberta Toronto Monsanto Canada Limited 175 Rexdale Boulevard Pexda/e, Ontario Vancouver Monsanto Canada Limited 1550 Pend Avenue Vancouver 14, B.C. Chile Monsanto Chile Comerciale Industrial Ltda Edilicto Espana. Oficinas 502 Ca/le Estado 337 Italy Monsanto Italians SpA 24 Via F. Fihi 20124 Milano Japan Monsanto Japan Ltd. Room 623. Chiyoda Building 14, 2-chome Chiyoda ku Tokyo Mitsubishi Monsanto Chemical Co. Mitsubishi Main Building 5-2, Marunouchi2-chome Chiyoda-ku Tokyo 100 Btomma - Stockholm Taiwan Monsanto Far East Limited 23 Chung Shan North Road 7th Floor. Section 2 Taipei Thailand Monsanto Thailand Limited Thai Farmers Bank Building 142 Silom Road Bangkok United Kingdom Monsanto Chemicals Limited 10-18 Victoria Street Santiago Malaysia London S.W. 1 Colombia Monsanto Colombians, Inc. Carrera 15 Ho. 77-50 Bogota Monsanto Far East Ltd. 116 Jafan Semangat Peta/ing Jaya Selangor U.S.A. Monsanto Company 800 North Lindbergh Boulevard St. Louis, Missouri 63166 Dominican Republic Monsanto Dominicana, Inc. Jose/a Perdomo f17 Esquina Pasteur Santo Domingo Mexico Monsanto Mexicana, S.A. Thiers Ho. 248 Colonel Aniures Mexico 5 Venezuela Monsanto (Venezuela) C.A. Torre Phelps -- Piso 24 Plaza Venezuela Caracas Representatives in principal cities of the world Monsanto Monsanto Company / Organic Division. Specialty Products / 800 North Lindbergh Blvd. / St. Louis, Missouri 63166 PZ-0471-IGI-LRA LITHO IN U.S.A. Ob 10141 TOWOLDMONOQ35384