Document EaYqyRJEVmmk772G3J6rqm64
USEPA at any time subsequent to the effect.lye date of this Section, the owner or operator... of an emission source located In that couiity: . . ' or any county contiguous to that county who ' -. would otherwise be subject to the compliance date In subsection (b) shall comply with the requirements of . sections 2IS.60) through 21S.603 within one year from the date of redestgnatton but In no case later than Oiqcfenber 31, 1987.
(Source:: Adopted at 7 Ml. Reg. 1244. effective January 21. 1983.)
Section 215.60S Compliance Plan ..
The owner or operator of an emission source subject to Section 215.604(a) shall submit to the Agency A compliance plan, pursuant to 35 111. Adm. Code 201. Subpart H. including a
project completion schedule where applicable, no later'than, for Section. .215.601(a) and (b). April; 21. 1983.
;
b) The' owner or operator of an emission' source subject to Section 215.604(b) shall submit to
the Agency a compliance plan. Including a project completion schedule where applicable,
no later than December 31.1986.
c) The owner or operator of an. emission source
subject to Section 215.604(c) shall submit a compliance plan. Including a project completion schedule within 90 days after the date of redesignation, but In no case later than Oecember 31. 1986.
d) Unless the submitted compliance plan or schedule Is disapproved by the Agency, the owner or operator of a facility or emission source subject to the rules specified In subsection, (a). (b) or (c) may operate the emission-source according to the plan and .schedule as submitted.
e) The .plan and. schedule shall meet , the requirements of 35 Ml. Adm. Code 201. Subpart H, Including specific Interim dates
as required In 3S 111. Adm. Code 201.242.
(Source: Adopted at 7 111. Reg. 1244. effective January 21. 1983)
*
Section 215.606 Exception to Compliance Plan
Coin-operated dry cleaning operations and dry cleaning facilities, consuming'less than 30 gallons per month (360 gallons per year) of perchloroethyTene are not required to submit or obtain an Agency approved compliance plan or project completion.schedule.
(Source: Adopted at 7 111. Reg. 1244. effective January 21. 1983)
Section 215.607 " standards for Petroleum Solvent Dry Cleaners
a) The owner or operator of a petroleum solvent dry cleaning dryer shall either:
1) Limit emissions of volatile organic
material to the atmosphere to an average oi~ 3.5 kilograms of volatile organic material per 190 kilograms dry weight of articles dry cleaned., or
2) Install and operate a solvent recovery dryer. In a manner such that the dryer remains closed and the recovery phase continues until.a final, solvent flow rate of SO mllltliters per minute is attained.
b) The owner or operator of a petroleum solvent filtration system shall either:
1) Reduce the volatile organic material content In all filtration wastes to 1.0 kilogram or less per 100 kilograms dry vmtght aP artlcley dry cleafted."before
disposal, and exposure to the atmosphere. ' or
2) rnstaTT ahd operate a carlrfdge
,
. filtration system, and drain the filter
cartridges in their sealed housings for 8
hours or more before their removal.
(Source: Added.et VI Reg.. 2296,,ettecltve_ April 3. 1987)
Section 215.608 Operating Practices for Petroleum Solvent Ory Cleaners
In order to minimize fugitive solvent emissions, the owner or operator of a petroleum solvent dry cleaning facility shall employ good housekeeping practices Including the following: "
a) General.Housekeeping Requirements
1) Equipment-containing solvent (washers,
dryers, extractors and filters) shall remain closed at all times except during . load transfer and maintenance, tint
filter and button trap .covers shall remain.,closed..except when solven.trladen material Is being removed.
2) Cans, buckets, barrels and other
containers of solvent or of solvent-laden
material shall be covered except when In
. . use.
3) Solvent-laden material- shall be exposed to the atmosphere^ooly for the minimum time necessary for load transfer.
b). Installation and operation of equipment:
1) All cartridge filters shall be enclosed
and operated In accordance, with the procedures and specifications recoronended bythemanufaclurerforthe cartridge. filter. After installation, the cartridges shall, be inspected,.monitored
and maintained in accordance with the manufacturer's -reconmendatlohs; and
2) Vents on containers for new solvent and for solvent-containihg waste shall be
constructed and maintained so as to minimize solvent vapor emissions.
- 127 -