Document EVr4mynrwZ9d09z1MLqpDLg4

! THE HARTFORD TRODUCTION **. rtc-h 3C IWiiUSTitlAL VAx WOBURN, MA 01801 i ww*j vw...MUk wurnniMcni 1 environmental sciences unit On May 11, 1983 a series of environmental tests were made at the A.V. Chesterton Research Facility at 30 Industrial Way, Woburn, MA 01801. The purpose of the evaluation was to monitor a simulation of the cutting, installation, and removal of asbestos-containing packing materials. Packings for both valves and pumps were utilised, during the simulation. The study was requested by David Lasnier, General Manager, A.W. Chesterton, and the evaluation were conducted by Stephen W. Campbell, Certified Industrial Hygienist, Hartford Insurance Group, Boston. Special thanks to Jack Santolucito and Bob Leduc for their eime and courtesy. This report represents the conclusions, recommendations, test methods and test r suits of the data obtained on May 11, 1983. v CONCLUSIONS 1. Airborne levels of asbestos measured during the simulation were all well below those limits generally regarded as safe. The sample that was obtained for the entire monitoring period of all six types of packing indicates levels of only 0.03 fibers par cc of asbestos. CSHA's legal limit for an 8-hour exposure to asbestos is 2.0 fibers per cc. 2. The simulation is deemed appropriate for the monitoring of the cutting and installation of asbestos containing packing materials. It should be noted that the removal of these packings from pumps and valves in field use may well pose a somewhat higher that monitored. 1 <ly> I THE HARTFORD a . y - *s'.tci5 3C INDUSTRIAL Wai WOBURN, MA 01801 ICSS DuNTP.D* DEPmhiMENT T ENVIRONMENTAL SCIENCES UNIT ( The reason for Che increased risk is associated with Che deteriorated condition of the packings often experienced under normal wear and tear. The packing removed during the simulation was relatively new and intact; thus, the likelihood of generating airborne fibers of asbestos was substantially reduced. RECOMMENDATIONS Normal field operations involving the removal, cutting and installation of asbestos packing typically takes between 10-30 minutes. The variability is reportedly largely dependent upon the difficulty in removing the worn asbestos containing packing from valves or pumps. For test data to be truly meaningful, it is necessary to approximate field conditions as closely as possible. What is necessary, then is to obtain samples during removal of asbestos containing packing that has been "abused" under actual conditions of use. As mentioned previously, the evaluation serves as a useful measure of employee exposure to asbestos during the cutting and installation of asbestos containing packings. Those values listed in the test results section of this report may veil understate the actual amount of asbestos experienced by a field person during the removal of worn packing from valves and pumps. Accordingly, the following recommendation is being submitted. 83-A In order to approximate more closely a real field situation, monitoring of asbestos exposure to the removal of worn packing materials should be simulated. If it is possible to provide for several types of packing materials to be tested at one time. The Hartford's Loss Control Department vnn'M v*-ry nnch like to conduct this type of testing again. V The purpose of the study was to approximate employee exposure to asbestos during typical field operations for the removal, cutting and installation of various packing materials. A member of A.W. Chesterton's research staff *c c^e Woburn facility assisted by simulating these operations utilizing 3 types of valve packings and 3 types of pump packings. Each of these packing materials was cut to length, installed in the appropriate equipment, momentarily brought up to normal operating conditions, and then removed.. The total time for this procedure involved approximately 10-18 minutes. One sample was taken during the entire procedure involving all 6 types of packing materials. In addition another sample vas collected for each of the individual packing materials to measure the exposure created by that one substance. The entire sampling period involved 97 minutes comprised of 6 separate sampling eriods ranging from 14--18 minutes each. All samples were collected on millipore type AA0.8 micron cellulose acetate filters mounted in 3 piece open faced cassettes attached to the lapel of the operator. Air vas drawn through these filters vith the use of Mine Safety Appliance Model G Vacuum Pumps set at flow rates approximating 2.0 litres per minute. Analysis of samples vas conducted by phase contrast microscopy. This technique measures all fibrous material present on the filter and may tend to overstate the actual presence of asbestos material. Periodic calibration of all equipment and analysis of all samples takes place at The Hartford's A1HA Accredited Laboratory in Hartford, Connecticut. V Cc>` <43 Jge& THE HARTFORD L1 fMV 30 INDUSTRIAL WAY WOBURN, HA 01801 fI | ENVIRONMENTAL SCIENCES UNIT TEST RESULTS All samples were collected on Jack Santolucito as he simulated the cutting. installation and removal of asbestos--containing packing. Sample #30 remained on his left l'apel for the entire sampling period , whereas samples #31-37 were changed with each style of packing. The results obtained are all quite low and indicate exposures well below those levels generally regarded as safe. SAMPLE # 30 TOTAL TIME (HRS:MIN) 1:37 TOTAL VOLUME(L) 189 TOTAL FIBERS 6,000 FIBERS/cc 0.03 STYLE PACKING All listed below 31 0:16 32 43,000 l 0.09 Valve 1000 32 0:15 30 43,000 4.0.09 Valve 1500 ( 33 34 0:14 0:14 29 4.3,000 4. 0.09 28 7,000 0.25 Valve 5010 Pump 1722 Whitelon. 35 0:18 36 3,000 0.08 Pump 320 Blueon* 36 0:18 36 3,000 0.08 Pump 330 OSHA's 8-hour legal limit ACGIH TLV - Chrysotile ACGIH TLV - Amosite ACGIH TLV - Crocidolite 2.0 2.0 0.5 0.2 * Hose likely contains crocidolite, whereas all others most likely contain chrysotile asbestos. exposure to airborne asbestos contamination Respectfully submitted. Stephen W. Campbell, CSF, CXH Certified Industrial Hygienist SWC/ea H EVALUATION OF AIRBORNE ASBESTOS DURING CUTTING, REMOVAL, AND PACKING OF PUMPS STEPHEN W. CAMPBELL, CSP, CIH JUNE 23, 1983 JUNE 28, 1983 INTRODUCTION As a result of a previous study and recommendations made at that time, another evaluation of the simulated use of asbestos containing packing materials was conducted at the A. W. Chesterton plant in Woburn, MA. This latest study involved two sets of samples collected on June 23, 1983 and June 28, 1983. The first set involved strictly cutting of four types of asbestos containing packing material for a total of 65 pieces during a period lasting approximately one hour. The second sampling occurred several days later when a pump containing asbestos packing was dismantled, the packing removed, new packing cut, and installed. This procedure lasted only 17 minutes. The survey was conducted by Stephen W. Campbell, Certified Industrial Hygienist, The Hartford Insurance Group, Boston, MA. Special thanks to Jack Santoluccito, Bob LeDuc, and Victor DiDonato r their time and courtesy. This report represents the conclusions, discussion of findings, test methods and test results of the data obtained on June 23 and 28, 1983. CONCLUSIONS All samples collected during the cutting, removal, and repacking of asbestos containing packing materials demonstrate airborne levels of fiber well below those levels generally regarded as safe. In fact, levels were so low that no measurable amount of fiber was able to be detected during the sampling period. To provide an even more realistic assessment of this simulated exposure, additional tests should be performed during the removal of asbestos containing packing materials from pumps that have run for an extended period of time. Necessarily, such an approach will be ongoing by its nature, and will undoubtedly encompass a period involving several months. 0M SRC 735-0 DISCUSSION OF FINDINGS Testing conducted on June 23, 1983 involved essentially a blind test. Simply this means Chat Che material cut was known only to the operator and Che tester by the code letters A, B, C, and D. In an attempt to obtain as long a sample as possible, and to approximate the absolute "worst case condition", the operator cut packing rings from each of these materials for periods of approximately 14-15 minutes. Depending upon the type of material, Che amount available, and the ease of use, between 13-20 rings were cut from each of the unknown samples. On June 28, 1983 a very brief sampling period was chosen since the operator merely had to remove the packing from a pump that had been run for a period of 14 hours. The removal procedure lasted approximately 10 minutes, following which the operator cut new .ngs and installed them back into the pump again. This procedure approximates a more realistic assessment of the typical conditions faced in the field. Since the pump was only run for a period of 14 hours, the deterioration of the gaskets was not significant. Consequently, additional testing in the future will hopefully measure exposures found under more severe conditions of use. TEST METHODS As in the past asbestos samples were collected by placing a three piece open face cassette onto the lapel of the operator during the processes described. Samples were collected in the three piece open face cassette on a millipore type AA, pore size 0.8 rnicr'?"., 37 millimeter filter. Air was drawn through this apparatus with the use of a Mine Safety Appliance Model C Vacuum Pump operating at a flow rate of 2.0 liters per inute for the times indicated in the test results section. ( S*t & *. - - fiScd THE HARTFORD ( A. W. CLT'TSntc/fi COMMERCE WAY WOBURN, MA LOSS C0it:`:':0'. QE?ASTi5SNT environmental sciences unit In one instance the sampler was placed in an area extremely close to the stuffing box of the pump during the removal of asbestos containing packing material. Analysis of all samples and the periodic calibration of the vacuum pumps cakes place at The Hartford's AIHA Accredited Laboratory in Hartford, Connecticut. Analysis involved the counting of fibers via a phase contrast microscopy technique. TEST RESULTS - ASBESTOS All samples were collected on Jack Santoluccito during cutting of 5/16 inch or 10mm packing while cutting on a 50mm shaft on June 23, 1983. To simulate worst case conditions numerous cuts of -each type of packing were made and the entire procedure lasted 57 minutes and involved 65 cuts of various packing. SAMPLE TYPE PACKING TOTAL TIME(HRSrMIN) VOLUME(L) FI3ERS FIBERS/CC TOTAL CUTS 1 A, B, C & D 0:53 106 43000 40.03 65 2 A 0:15 30 </3000 40.10 20 3 B 0:14 28 <3000 40.11 13 4 C 0:14 28 Oooo 4o-ii 14 5 D 0:14 28 <3000 4o.ii 18 OSHA -- 8 Hour Time-Weighted Averagei Permissible Exposure Limit 2 .0 Fibers/cc The next series of samples were taken during the removal of A. W. Chesterton Model 2022 3/3 inch packing with A ffiOw e a ii44 cud r*r* free z. puzp * V e ^ run for hours. following removal of the six rings and the end ring another series of rings were cut and the pump was again packed for a future test. This activity took place on June 28, 1983 and the entire procedure lasted 17 minutes. Samples were taken on Jack Santoluccito and to the left side of the drive end of the pump stuffing box. LOCATION Jack SAMPLE 6 TOTAL TIME (HRS:MIN) 0:17 VOLUME(L) 34 FIBERS 43000 FIBERS/CC ^0.09 Area 7 0:17 34 43000 0.09 Hopefully this information has been of assistance to you in your attempt to field exposures to asbestos containing packing material. Respectfully submitted, ' -tephen V. Campbell, CSP, CIH Certified Industrial Hygienist SWC/ea