Document EJXj2YLZZ9m6nKgbOZ9YrNB4
Preliminary Dust Surrey for Asbestos Textile Institute, Juno, 1947.
.24
2. Secondly -- since the limit of resolution of the microscope
lenses used in dust counting does sot permit seeing particles very much smaller
than one micrcn, one any ask If there are many fibers of great length, hut of
such
vldth that they are invisible?
Samples of atmospheric dust vere obtained for omnination by the
electron aicroecope, by mounting the small specimen slide used vith -this
Instrumnt, in the dust collecting zees of the electric precipitator. Iaorder
to eliminate very large fibers, the air being sampled vas caused to psse first
through a glass spiral coated vith adhesive car Its Interior. This subjected
the dust particles to centrifugal force end the largest cares would be pre
cipitated. out, much ae they might be in the nasal passages of man.
Studies vith other industrial dusts employing this spiral indicate
'
- t'
that very rarely do cubical particles larger than three to five microns suc
ceed in passing through the several turns of the spiral.
In samples obtalnedvlth this apparatus in a card room having a
good dust, control, ve obtained, pictures, some of vhlch are reproduced In the
attached Figure. They demonstrate first, that the cubical particles seen by
a lev power light-microscope are in fact bundles of fiber resembling a life-
sire.handful of partially opened fibers.
The picture further demonstrated that there are many fibers of con
siderable length, sons fully 50 microns,, whose other dimension la only a -
fraction of a micron; the fiber is therefore invisible in the dust counting
nicrosoope.
N*