Document EBZLpzk3LRnm5vMxadK48EDn

April 27,1992 Dow U.S.A. The Dow Cherr'cal Comoa1"/ PO Box '50 PlacL.enrr'e Louisiana 70765-G'50 Daniel Cortez Eddie Guillory Petrin Petrin Building 4106 cc: Marty Morrison Utilities Building 1801 Asbestos Monitoring Enclosed are sample results for potential exposure to asbestos. The OSHA 8-hour permissible exposure limit for asbestos is 0.2 f/cc >5 microns and the 30-minute short term exposure limit is 1 f/cc >5 microns. The results displayed are based on sampling duration. The data sheet shows the results of exposure using two methods, the Limit of Detection (LOD) and the Limit of Quantitation (LOQ). Included on the data sheet is an explanation of the method Limit of Quantitation. Thank you, Darlene S. Creel Industrial Hygiene Ext. 6181 Building 3502-E Attachment dsc PRODUCED FOR THE ASBESTOS DATABASE DATE: MASTER No. _________________ 43 3$71 ------ DO A .1.14670 CONFIDENTIAL ASBESTOS MONITORING DATA RESULTS: UTILmES 1902 **LOD ***LOQ EXPOSURE GUIDELINES 8-HR. TWA LIMIT-0.20FIB/CC 30-MtNUTE LIMIT = 1.0 FIB/CC LIMIT OF DETECTION = 7 FIB/MM2 LIMIT OF QUANTITATION = 100 FIB/MM2 DATE SAMPLE # PERSONNEL DESCRIPTION DUR(MIN) * LOD ***LOQ VOL(D FlBffiC FIB/CC 4/23/92 13524 *439-11-1161 Insulator: Removing damaged 90 deg. from 435# steam line. WET METHOD USED 30 76 <0.01 <0.51 * The proper protective clothing was worn during the job. North 7700 Respirator with HEPA filters were worn during the job. Note: The Limit of Quantitation has been defined as 100 Fibers/MM2 using the minimum fiber loarfing criteria specified. In the NIOSH analytical method 7400, the stated range of the method is too to 1300 Flbers/MM2 filter area. Although samples below this range can be analyzed, the method has not been validated below 100 Fibers/MM2. However, the NIOSH method 7400 also establishes the estimated Limit of Detection as 7 Fibers/MM2 (Reference OSHA Std. 1910.1001, Appendix B). Based on this Information, we will establish 100 Flbers/MM2 filter area as our Limit of Quantitation and 7 Fibers/MM2 fitter area as our Limit of Detection (which is more representative of the actual fibers present) for asbestos monitoring. We wfN report both Limit of Quantitation and Limit of Detection. If only Limit of Quantitation were expressed, the minimum reportable result would calculate to be 0.04 Fibers per cc for an 8-hr. Time weighted average sample at a flow rate of 2 liters per minute and 0.6 fibers per cc for a 30 minute time weighted average short term sample at a flow rate of 2 liters per minute. ij i} A L I A o / 1 CONFIDENT! Al LOUISIANA DIVISION INDUSTRIAL HYGIENE SAMPLE RECORD 2sample N 13524 PLANT/DEPT. U 4~. 'ft h e.S MONITORING FOR: ^5 DATE, OTHER CHEMICALS PRESENT:______________ SAMPLE COLLECTION MEDIA: BADGE NO.____ TYPE. PUMP SERIAL NO. "7 3 ( 9 ( CALIBRATION DEVICE: O-POBBLEMETER ROTAMETER TEMP/HUMIDITY: (REQUIRED FOR BAOGES}_ OTHER________ \y'f CHARCOAL TUBE SIZE_________________ "flLTER CASSETTE SIZE z>C~ ffl m SILICA TUBE SIZE_________________ DRAGERTUBE TYPE________________ OTHER __________________________________ PUMP FLOW RATE CALIBRATION: BEGIN: 1. 2 3 3. BEGINNING FLOW RATE AVG '"Cc/MIN L/MIN SHIFT; erSHR. 12 HR. CT"PERSONNEL SAMPLE AREA SAMPLE FULL SHIFT TWA ENDING:1. 7 CRrTF STEl/TASK EMPLOYEE NAME, EMPLOYEE I.D.#_ JOB CLASSIFICATION. IH JOB CODE # CONTRACTOR COMPANY s -He i,'KuteJ<<- fiv7r, __ Cqjl 3 ENDING FLOW RATE AVG. ^5~&Q I 0^CC/MIN L/MIN SAMPLE AVERAGE FLOW RATE TIME STARTED _ TIME STOPPED _ I'm PM r.jo em TOT. RUNNING TIME(MIN). RESPIRATOR USED? *CfYES NO RESPIRATOR MODEL / CANISTER TYPE A/Or-tf' 17U'fesrtCt SAMPLE VOLUME {AVG FLOW X RUN TIME).-2k. MOUTH-BIT DUST S-HALF-FACE FULL-FACE AIR-LINE SCBA _5k= DESCRIPTION OF AREA SAMPLED/JOB PERFORMED DURING MONITORING __ f'VO'ir* C/~3S~~**r ANALYTICAL REPORT REFERENCE # ANALYTICAL RESULTS: O TT77r RESTRICTED FOR USE WITHIN DOW ONLY l_____ V <0,0\ C-Ot) VP-124 0 w1 \ LDQ FORM FILLED IN BY: J DO A 114o7 CONFTDFNTTA