Document E3r1jEj19kdw16Mw9Zb9eoXb
FILE NAME Kelly Moore KM
DATE 1976 Jan 8 DOC KM031 DOCUMENT DESCRIPTION Memo RE Sources for Excessive Emissions
PACO TEXTURES MEMO
TO Bob Miller
FROM Doug Merrill
SUBJECT SOURCES FOR EXCESSIVE EMISSIONS
January 8 1976
Location Paco Textures San Carlos
1 Bulk Storage Tanks
a Description - Three tanks containing separately clay
talc and limestone
b Equipment - 40 Hp M.D. Blower 400 CFM
3 steel tanks Bag house on each tank with
4 piping
10.53 sq
ft
of cloth
C. Source - Upset condition -
leaks
in pipes
tank
fittings or damaged bags Breakdown - None equipment
a Maintenance - Dusthouse
not used . cleaned weekly
socks
replaced as needed
e Usage - Not continuous
approximately
25 hours per
montaht one hour per truck load
.
- Dust Collector
a Description Central Collector for dust pickup
points within factory area
Collector
- ICA REES Model 3-700 Dust
b Equipment
ft of cloth
15 Hp Blower 6000 CFM
2100 sq clean air vent contaminated
C. Source - Upset condition
by damaged cloth Breakdown - None equipment a Maintenance - Monitored
not used daily by Manometer
with
annual
inspection of cloth
176 hours per month
.e Usage - Continuous approximately
Boiler ~~. _
a Description - Exhaust for boiler
b Equipment - 25 Hp boiler .c Source - Upset condition - none auto Breakdown - none equipment not used
a Maintenance - Annual inspection
e Usage - Continuous approximately 150
shut
hours per
month
DWM
KM BB 5454