CEA-1800 - Aroclor Expansion - W.Q.K. 0230079 TOWOLDMONOQ45526 M eeting Agenda . AGENDA ' For Directors Review Meeting On Aroclor Expanslon-WGK (CEA l800) . 'i I. Introduction--------------------------------- W. A. Kuhn and/or J. W. Molloy II. Objectives (Dated 8/27/68 and Previously Issued) -- Specific Questions III. Chemistry of Process------------------------------ C. W. Hamlet - PR&D IV. Summary of Plant Process and Equipment -- R. S. Yates - CED V. Current Status of Project A. Construction ------------ ------------ r. s. Yates - CED VI. VII. B. Manning ---------------------- ---------------- h. F. Ray - Mfg. C. Training Program ------------------ H. F. Ray - Mfg. D. Overall Timing -------- ---------------- H. F. Ray - Mfg. Start-Up Plan ----------------------------------------------- H. F. Ray - Mfg. Project Risks A. In Process--------------- ---- C. W. Hamlet - PR&D B. In Design ------------------ ------ R. S. Yates - CED C. In Operation ------------ ------ H. F. Ray - Mfg. 02300 TOWOLDMONOQ45527 S tart-U p Aroclor Expansion - WGK (CBA-l800) Start-Up Objectives A. Overall Primary: 1. Demonstrate safe operation of the expanded Aroclor process within the control limits prescribed by PR&D in Tentative Process No. PI 50*1. Secondary; 1. Produce Aroclors which meet the specifications outlined in the Tentative Process. 2. Demonstrate the ability of the facilities to produce at designed capacity, specifically: . Aroclor 1242 40 Ji#/Yr. All Other Aroclors 30 M///Yr, Total - 70 K#Ar. . 3. Demonstrate the ability of the facilities to realize cost standard biphenyl yield or better on total Aroclor production, specifically: Raw Material Biphenyl # Theory Yield 97# Demonstrate the ability of the facilities to meet standard manufacturing cost. 5. Achieve the above objectives within a 45-day start-up and demonstration period and within budgeted start-up expense. B. Technological Objectives 1. Demonstrate the optimum Continuous porocel absorption column operating conditions in terms of capacity, quality, porocel usage and product loss. 2. Demonstrate the ability of the ferric chloride catalyst addition system to insure proper catalyst level in the continuous chlorinator line. 3. Demonstrate the ability of the "dynatrol" to control the Aroclor 1142 specific gravity within specification limits. 4 Demonstrate the ability to continuously monitor the power factor of the finished product with the in-line analyzer developed at Anniston. . _,, / \UJ4 ^ ^4, 02 30081 TOWOLDMONOQ45528 -2B. Technological Objectives (continued) 5. Demonstrate the effect of maintaining finished product elec trical properties (Power Factor and Resistivity) during extended storage periods through use of nitrogen blanketing. 6. Evaluate the effect of aging Aroclor 1142 on Aroclor 1242 stability. 7. Demonstrate operating conditions which will allow duplication of Anniston production. 0230082 TOWOLDMONOQ45529 Manning _Cha^^-- FOREMEN Premium w Still w Second | Oper. (4)| Swingman #2 (1) Standard (2) I 7 Days/Wk. 7 Days/Wk. 7 Days/Wk. 3 Shifts/Day| 3 Shifts/Dajy 3 Shifts/Djay Duties Batch Duties 2 Stills Duties 5 Chlorinato bs (Existing)j 3 Mix Tankp (Existing) Continuous 4 Chlorinato ,3 New 2 Stills j I| Tank Farm Load all Catalyst 1 Mix Tank 2 Blow Tanks Cars & (Existing)! Trailers 21st 5 DaysATk. Shift- 2 Shifts/ Still `Day 21st Shift - Duties Second S&S i All . Drum,,- Standard mins of 1 Day Standard material in Dept. Biphenyl 1 Head Tank (Existing) 1 Off Gas Condenser ; j { I | ( 4 Absorbers; &| Complete j Charge ofj Therminol! Heating ` System Pump Finished Product Tanks To Storage 1 Off Gas j Storage j Tank & Misi 1 Continuoujs Blow Tank! . Eliminator ij Sample \ 1 Surge Tank! ! Repair ' Swingman (1) i'#l CD 1 5 Days Monday .1 Shift 21st Shift Premium Biphenyl i Handling Thurs. & Frit & 2 Days i All Repair Repairman; Work Sat. & Sun. I 2 Days Relief Foreman Porter (1/2) i 5 Days/Wk. 1/2 Shift/Day Clean Control Room, Rest Room, 2 Offices & Smoking Shelter TOWOLDMONOQ45530 START-UP ORGANIZATION (Tentatively Effective 10/15/68) J. W. Molloy Gen. Supt. W. A. Kuhn TPM . ' -Dr o o R. S. Yates CED H. F. Ray Mfg. Repr. !' ! ' | V. Bravd.ey l Start-Up L foreman C. W. Hamlet PR&D ii J. Cagle | I W. Crabtree j ! T. Athmer ; ! G. Craine Relief/Shifti Relief j Foreman i ; Foreman ! ; Shift j Foreman : ; Shift . ; ! Foreman J. | ; V. Cook : i Shift : Foreman i TOWOLDMONOQ45531 T ra in in g AROCLOR expansion: (cea 1800) TRAINING PROGRAM . I. Course Content ' A,. Supervisory 1. Introduction to Key Personnel . 2. General' Indoctrination .. . _ 3. Dept. Tour ^. Dept. Organization 5. Security of Information 6. Process Technology 7. Review and Discussion ' 8. Introduction to Training ' 9. Assignments, Responsibilities and Authority 10. Process Equipment and Control Limits 11. Process Instrumentation ' , 1?. Assignments for Operator Training 13.- Operating Instruction of Existing Equipment 1*). Safety 15. Materials Handling 16. Utilities 17. Quality 18. Yields 19. Economics 20. Process Description 21. Risk Analysis 22. Communications 23. Equipment Repairs 2h. Records 23. Follow Process in Field 26. Preparation for Water Batching 023008^ TOWOLDMONOQ45532 COURSE CONTENT A. Shift Supervisors -2- Week Beginning Sept . $7 '1<55ET Sept. 16, 1968 Sept. 23. 3968 Sept. 30, 1968 Subject Introduction to Key Personnel General Indoctrination Dept. Tour Department OrganiEation ' ; Security of Information Process Technology Review and Discussion of First Week Subjects Introduction to Training Assignments, Responsibilities, and Authority Process Equipment and Control Limits Process Instrumentation Process Technology Operating Instructions of Existing Equipment Assignments for Operator Training Review and Discussion of Previous Subjects. Safety Process Instrumentation Materials Handling Utilities Quality Yields, Economics Process Technology Process Description Risk Analysis Review and Discussion of Previous Subjects Communication Follow Process Flow in Field Materials Handling Records Equipment Repairs Check-out on Preparation for Operator Training Risk Analysis Review Preparation for Water Batching Materials Handling o;?30OB6 TOWOLDMONOQ45533 MASTER TRAINING SCHEDULE Shift Supervision -3- Week Beginning Sept. 9, 1968 Sept. 16, 1968 Subject 1. Introduction to Key Personnel H. Ray - Manufacturing Representative and Dept. Supv. R. Yates'- Project Manager (C.E.D.) J. Molloy - Production Superintendent ' V,_ Brawley -Dept, Foreman R. Cederstrom - CED Construction Supt. 2. General Indoctrination Introduction to Aroclor Hovj it is made Uses 3. Dept. Tour Existing Equipment New Equipment 4. Dept. Organization Salaried Supervisor Foreman Hourly Relief Foreman Premium Oper. Still Oper. Sc-COi'iCi Gpci . Standard Oper. Repairman Porter 5. Security of Information Reason for Security 6. Process Technology a. Batch b. Continuous 1. Review and Discussion of First Week 2. Introduction to Training Subjects to be Covered Trainers 3. Assignments, Responsibilities and Authority Assignments - shift coverage of entire " dept, making flow sheets, completing IFO's, devise data sheets, etc. Responsibilities - Supervise safe running of equipment by hourly personnel, produce scheduled pounds of quality material as outlined in the Start-up Objectives. - 0?30oei TOWOLDMONOQ45534 MASTER TRAINING SCHEDULE (cont1d) Shift Supervision (cont'd) Week Beginning Sept. 16, 1968 Sept. 23, 1968 Subject ' " 3. cont'd. . . Authority - Overall direction of all operators and operations. Make decisions on process changes for safe operations and quality material. Have equipment main tained on shifts and weekends. 4. Process equipment and control limits. Explanations of the function of each piece of equipment and safe limits of each. . Make flow sheets for operator training. 5. Process Instrumentation V.B. - Explain instrumentation on existing equip . L.V. - Explain instrumentation on new equip. Complete IFO's on new equip. 6. Process Technology 7. Operating Instructions of existing equipment. Read & discuss Operating Instructions. 8. Assignments for Operator Training Brawley - Biphenyl and catalyst mix tank. Sp. Gr. controller. Craine - All chlorinators and Intermediate Storage Tank. Athmer - 3 Blow tanks, 4 stills, therminol system. Cook - All still receivers, surge tanks, blend tanks, absorbers, finish product tanks and power factor analyzer. 1. Review and discussion, of previous subjects. 2. Safety . General Dept, safety, clean-up and house keeping. Plant disaster plan for plant and dept, location and use of safety showers, fire extinguishers, gas masks, Scott air pak, emergency clothing, stretcher, fire alarm and eye protection. o2300 TOWOLDMONOQ45535 . -5MASTER TRAINING SCHEDULE (cont'd) Shift Supervision (cont'd) Week Beginning Sept. 23, 1968 Subject 2. cont'd. List safety devices for new equipment. List all grounding points in existing and new Equipment. Hold Safety Review for.project. 3. Process Instrumentation Complete writing IFO's. 4. Materials Handling Cover all chemicals used in dept., toxicity consistency, special precautions. Use "Standard Manufacturing Process" for existing dept. Sample raw materials for identification. 5. Utilities Utility Plant Air Inst. Air . 80# Steam 200# Steam City Water Natural Gas Line Location and Shut-Off Ground Floor at Catch Pot. Ground floor north of air dryers. High-line - Dent. 25^4 tl tl II ' tl Next to roadway, south of water tank. Ground floor, north of sprinkler house. 6. Quality Review Spec Sheets List most critical properties List frequent problems and solutions Discuss sampling. List sample needs on start-up. 7. Yields, Economics Review 1969 Cost Standard (Start-up) Process yield loss points Blends 8. Process technology Read and discuss tentative process for continuous unit. 9. Process Description Read and discuss process description of new equipment. 0? 300 89 TOWOLDMON0045536 .. 6- - - MASTER TRAINING SCHEDUXE,(uont-id) Shift Supervision (cont'd) - Week Beginning Sept. 23, 19^8 Sept. 30, 1968 Subject 10. Risk Analysis Read and discuss risk analysis for start-up of new equipment. .1. Review and'discussion of previous subjects 2. Communications Verbal Written 3* Follow process flow in field. Trace all process lines in existing and new equipment. Check out all instruments 4. Material Handling Explain trailer, car and drum loading. How to inspect each. 5. Records ' Make new data sheets for gathering in formation on start-up. Also determine where samples are to be taken, how many, what size and frequency. 6. Equipment Repairs Discuss equipment repairs that must be made soon as possible and what equipment can wait until next day. Also discuss how to contact necessary crafts on nights and weekends. 7. Check-out on preparation for operating training. Make certain each man is prepared to train, knows when to train and knows who he must train. 8. Risk analysis review Review risk analysis so possibly problems and possible solutions are discusseu and known. 9. Preparation for water-batching Make final check on equipment. . Discuss what material will be used for water-batching, how it will be transferred and what will be done with material after water batching. . Check inventory of material carefully. 0230090 TOWOLDMONOQ45537 B. Premium Operator Week Beginning Sept. 30, 1968 ' ' . . .' . '* , Subject Water-batch Biphenyl/catalyst mix tank .. Check-out instrumentation on Bi0/catalyst mix tank. Water-batch #6 through #9 chlorinators. Check-out instrumen+ation on all chlorinator-. Check-out instrumentation on intermediate storage tank. Check-out panel alarms and instruments. Trouble Shootings . Equipment Failure Sampling Data Sheets 1. Water-batch Biphenyl/catalyst mix tank. Fill mix tank with 1242 Aroclor. Circulate to check-out line and pump. 2. Check-out instrumentation in Biphenyl/catalyst mix tank. Check-out all instrumentation in field and on panel board, including timer. 3. Water-batch #6 chlorinator Fill #6 chlorinator with 1242 Aroclor. Circulate to check out line and pump. 4* Ciicciv-Out instruriientation on -jlv Cnloi'iuat,oi', Check-out all instruments in field and on panel1 board. Oct. 1, 1968 Oct. 2, 1968 1. Water-batch #7, 8 and 9 chlorinators. Check-out all instruments in field and on panel board, giving special attention to the specific gravity controller. 1. Check-out instrumentation on intermediate storage tank. Check-out all instruments in field and on panel board. 2. Check-out panel alarms and instrument control points. Discuss each alarm on panel board stating problems and corrections. Discuss settings and control points on instruments. TOWOLDMONOQ45538 B. Premium Operator Week Beginning ' Subject Oct. 3, 1968 ,' ' 1. Equipment failure Discuss equipment failure and power failure. Sampling Discuss sampling frequency, size bottles, reason for and necessary analysis. '3.' Data Sheets ................. Discuss record data sheets, what data is needed, how to record and what it should mean to operations. 4. Check-out HC1 line to condenser and drowning .let. Check-out valve line-up from each chlorinator to the HC1 condenser and to the new drowning jet. 5. Check-out chlorine lines Check-out lines and instrumentation for chlorine addition to each chlorinator. Oct. k, 1968 1. Review and discuss all equipment and training. 0230092 TOWOLDMONOQ45539 t1 -Aroclor Expansion-(CBA-1800) Training Program C. Still Operator Content . - ' 1. General Indoctrination 2. Dept. Organization 3. Introduction'to Personnel :4. Dept. Tour ................ 5. Security of Information .6 Safety and Housekeeping 7 Introduction to Training ' 8 Classroom Training 9. Field Training .10 Materials Handling - 11. Quality 12. Sampling 13. Instrumentation 14. Trouble Shooting 15. Recording Data 16. Plant Disaster Plan . 17. Discussion ^Ooy3 TOWOLDMONOQ45540 C. Still Operator 1st Week General Indoctrination ........... Dept. Organization, - , Introduction to Personnel Dept. Tour , Security of Information ' .Safety and Housekeeping Introduction to Training Train on Existing'Equipment . 2nd Week Monday Tuesday Wednesday Thursday Friday Review Training of Previous Week Materials Handling Quality Sampling , Classroom Training on function of equipment ' Field training for location of equipment, lines and process flow. . Field training for location of instruments Classroom training for function of instruments - Field training on complete operation of continuous blow tank. " " " " still operations ** ** ** + V< o r>m /*> T_ C'yrc'+Ckm Field training on receivers 3 and 4, surge tanks 3&4, All 4 porocel absorbers both Power Factor Analyzers and finish product tanks 3 and 4. 3rd Week Monday Tuesday Wednesday Thursday Friday Review and discussion of previous training. Safety, plant disaster plans. Field train on rework and transfer lines. Field train on therminol system. Field training on complete process flow on all 4 still systems. Review instrumentation and panel board. Trouble shooting and discussion on equipment failure. Review record sheets, how to fill out, where to get readings and samples. Run //I and ^2 stills. Open discussion of all equipment and training. Final check-out in field of any problem or question : ' able areas. 023009*1 TOWOLDMONOQ45541 C. Still Operator 1st Week 1. General Indoctrination Introduction to Aroclor, areas of responsibil ities, plant and dept, procedures. 2. Department organisation Salaried Hourly H. Ray - Dept. Supv. Premium Operator J. Molloy - Prod. Supt. Still Operator V. Brawley - Foreman Second Operator J. Cagle - " Standard Operato: T. Athmer - " Repairman G. Craine - " Porter V. Cook - " G. Schwartztrauber- Cost Analyst 3. Introduction to personnel it. Dept, tour Existing Equipment New Equipment 5. Security of information Reason for security 6. Safety and Housekeeping - Discuss dept, safety record, eye protection, safe working habits. Location and use of emergency equipment iiow to turn in fire alarm. Discuss housekeeping expected. 7. Introduction to training Discuss briefly how training will be done, subjects to be covered and probable timing. 8. Train on existing equipment Actual training with Premium Operator on existing blow tanks, preheater, stills 1 and 2, jets, receivers, blend and finish product tanks, city water tank and pumps. 2nd Week Monday . 1. Review training of previous week. Discussion of Stills 1 and 2 2. Materials Handling Discuss all chemicals used on immediate job in respect to toxicity, consistency, special precautions. ' 3. Quality Review spec sheets and discuss how the opera tion will affect the material specifications'. 023q`> TOWOLDMONOQ45542 C. Still Operator -; - - " 2nd Week Monday (cont'd) 4.' Sampling--------------- ----- --------- Discuss sampling. Importance of good samples and how to sample. . 5. Classroom training on function of equipment. Chalk talk on function of new equipment and safe limits of each. Tuesday 1. Field training for location of equipment, lines and process flow. Identify new equipment,' trace out all connecting lines and follow process flow. Wednesday . 1. Field training for location of instruments Locate instrumentation in the field and Identify its function. 2. Classroom training for function of instruments. Chalk talk on function and operation of instruments. Thursday ' 1. Field training on complete operation of con tinuous blow tank. Dry-run complete operation of the continuous blow tank. 2. Field training on complete operation of #3 & #4 still operations. Dry-run complete operation of Stills 3 & 4. 3. Field training on complete Therminol system. Dry-run complete operation of therminol system. Friday 1. Field train on receivers 3 & 4, surge tanks 3 & 4 all 4 porocel absorbers, both power factor analyzers and finish product tanks 3 & 4. Dry-run complete operation of the above equipment. 3rd Week Monday ' 1. Review and discussion of previous training. Review and discussion of all equipment. 2. Safety and Plant Disaster Plan. Discussion of all safety devices including therminol unit. Review of the Plant Disaster Plan. 3. Field train on rework and transfer lines. Trace all connecting process lines so necessary transfers can be made. Also locate all valves in lines. o?3ocm TOWOLDMONOQ45543 C. Still Operator 3rd Week Monday (cont'd) 4. Field train on Therminol system. Final check-out on Therminol system. Tuesday 1. Field train on complete process flow on all . 4 still systems. Dry-run complete operations of all 4 still systems. Wednesday 1. Review instrumentation and panel board. Discussion of panel alarms and how to correct problems. Also demonstrate how to change charts. 2. Trouble shooting and discussion on equipment failure. Discuss how to correct problems indicated on instruments on panel board and in field. Discuss in detail, equipment failure and power failure. Thursday 1. Review record data sheets, how to fill out, where to take readings and samples. Discuss record data sheets so each operator will know what data is needed and how data should be recorded. Also where readings are to be taken from and what they should mean to operations. 2. Run Stills #1 and #2. Run existing Stills 1 and 2 at direction of Premium Operator. Friday 1. Open discussion of all equipment and training. Question, answer and discussion of any or all subjects. 2. Final check-out in field of any problem or questionable areas. Make final check-out in field, of previous known problem areas of equipment. O?^0'7 TOWOLDMONOQ45544 C. Still Operator 3rd Week __ (Alternate Plan)_______________ Monday ' Review and discussion of previous training Water batch & simulate continuous blow tank operation. Water batch & simulate #3 Still operation, . - #3 Receiver, Surge tank, then ' Finish Product Tank. Tuesday Water batch & simulate #4 still operation, . #4 Receiver, Surge tank, then Finish Product tank. Trouble shoot during simulation.- Wednesday Water batch & simulate Therminol system operation Pack all Porocel absorbers. Thursday Review record sheets, how to fill out, where to get readings & samples. Review instrumentation on panel board Field train on rework and transfer lines. Discuss equipment and power failure. Discuss polishing filters on absorber lines. Friday Open discussion of all equipment and training. Final check-out in field of any problem or question able areas. 0. Still Operator 3rd Week Monday (Alternate Plan) 1. Review and discuss previous training. 2. Water batch and simulate continuous blow tank operation. Fill continuous blow tank with 1242 Aroclor and simulate actual operation, pumping material to #3 still pot. 3. Simulate actual operation of #3 still line. Circulate material in $3 still pot, check-out all possible instrumentation, then move materia] to #3 receiver, surge tank, and finish product tank. Tuesday 1. Simulate actual operation of #4 still line. Circulate material in #4 still pot, check out all possible instrumentation, then move material to #4 receiver, surge tank, and finish product tank. 2. Trouble shoot during simulation. Trouble shoot in each possible area to learn possible problems and corrective action needed. OZ30098 TOWOLDMONOQ45545 C. Still Operator 3rd Week (Alternate Plan) - cont'd Wednesday 1. Water-batch and simulate Therminol system operation. Fill Therminol surge tank with 12^12 Aroclor and simulate actual operation, checking out instrumentation and trouble shoot to learn possible problems and corrective action needed. , 2. Pack Porocel absorbers. Fill absorbers with Porocel. Thursday 1. Review record sheets, how to fill out, where to get readings and samples. Review record sheets, discussing what informa tion is needed and what value the readings should be to the operator and why it is necessary to record it. Also discuss sampling, where to get samples and what is to be done with * them. 2. Review instrumentation on panel board. Final check-out on panel board. 3. Field train on rework and transfer lines. . Discuss equipment failure and power failure. Discuss what is expected to happen if any equipment should fail and necessary action to be taken. Discuss what will happen to equipment if the power fails and what are the most critical operation to be performed after failure. 5. Discuss polishing filters on absorber lines. Discuss polishing filters, purpose, and actual change of cartridges and gasket. Friday 1. Open discussion of all equipment and training. 2. Final check-out in field of any problem or questionable areas. 0? 30099 TOWOLDMONOQ45546 S tart-U p CEA-1800 - AROCLOR EXPANSION - WGK Start-Up Plans PROJECT SCHEDULE In order to demonstrate the expanded Aroclor facilities at WGK while adhering to the requirements outlined in the start up objectives. Phase II will be completed on the following construction schedule. Construction Phase II Area Completion Date A. Off-gas Purification System 9/4 B. Chlorinator Area (catalyst mix tank thru continuous blow tank) 9/30 C. Therminol System 10/14 D. #3 Still System and #1 Absorber (1242 Line) 10/21 E. #4 Still System and #2 and 3 Absorbers (1248/1254 line) 11/4 F. #4 Absorber (1260 line) ll/ll G. Anniston Duplication 11/18 thru 12/1 (Demonstration) PROJECT DEMONSTRATION A. Off-Gas Purification System - This system was activated on 57^ due to earlier failureof the existing department puri fication system. The equipment was thoroughly checked out prior to start-up and as a result no operating difficulties were incurred. The only aspect of the system not yet demonstrated is utilization of the material recovered from the off-gas in production of non-electric Aroclor. This will be completed as soon as sufficient material has accumulated. I B. Chlorinator Area - Process simulation will be accomplished using-Aroclor 1242. Chlorination control in the continuous line will be checked out by chlorinating the 1242 to 1148. Catalyst addition effectiveness will be measured by allowing an Aroclor 1242/catalyst mix to cascade thru the system. When the above operations have been checked-out (1 week maximum) the continuous chlorinator line will be brought on-stream to produce Aroclor 1142. This material will be collected in the intermediate storage tank brine which it will either be trans ferred to the existing #1 and #2 blow tanks for future pro cessing to Aroclor 1242, or else transferred to the batch chlorinator head tank for further chlorination. C. Therminol System - This system will be charged with Aroclor 124b from the department storage tanks. The entire therminol control system can be demonstrated prior to start-up of the stills. 0230100 TOWOLDMONOQ45547 PROJECT DEMONSTRATION (continued) D. #3 Still System and #1 Absorber (1242 line) - This line will be simulated using Aroclor 124?. Complete checkout of the system excepting effectiveness of tie-up of residual HC1 and ferric chloride with lime will be possible prior to actual start-up on Crude 1142. Demonstration of this system will allow production of Aroclor 1242 and one other Aroclor simultaneously. Only the 1242 will be upgraded in the Porocel columns at this point; however. E. y/4 Still Area and #2 and 3 Absorbers (1248/1254 line) - This Tine wilT be checked out similar to the procedure outlined in Section D. Start-up of this system will allow demonstra tion of the 40 M #/yr. Aroclor 1242 design rate as well as the effect of porocel treatment on Aroclors 1248 and 1254. F. #4 Absorber (1260 line) - This line will be checked out with ArocTorr_l242 prior to start-up. Start-up of this system will allow demonstration of the effect of porocel treatment on Aroclor 1260. G. Anniston Duplication - Start-up of Item F completes demon stration of the design premises outlined in the CEA-1800 scope report. The final item to be demonstrated in the start-up objectives is duplication of Anniston production. Process conditions will be modified at this time to conform with those at Anniston in attempt to duplicate this produc tion and allow shipment to any customer from both plants. ghw cc: Messrs. R. S. Yates C. W. Hamlet R. Kuster J. W. Molloy V. Brawley J. Cagle T. Athmer V. Cook G. Craine R. Cederstrom Prepared by; H. F. Ray ^3ojoi TOWOLDMON0045548 W. G. Krummrich Plant Sauget, Illinois August 22, 1968 Aroclor Expansion - WGK (CEA 1800) Risk Analysis; D. C. Armstrong - WGK V. Brawley - WGK M. S. Feld - WGK ' T. E. Greeninan - WGK C. W. Hamlet - WGK J. R. McClain - WGK R. M. McCutchan - WGK J. W. Molloy - WGK P. Verna - WGK H. S. Bergen - G.O. D. B. Hosmer G.O. R. E. Howard R. M. Kounts - G.O. G.O. W. A. Kuhn G.O. R. J. Stratmeyer - G.O. M. E. Gibbs - 2nd St. R. H. Munch - 2nd St. A nalysis Attached are the Aroclor Expansion - WGK (CEA 1800) Risk Analysis Data Sheets indicating the major and minor risk considerations in this start up. Consider able preventive action has been taken to minimise the risk involved in the major problem areas. If there are questions concerning this analysis or any of the risks indicated, do not hesitate to contact the appropriate representative of CED, Research (PR&D) or Manufac turing. Hi F. Ra Mfg. RejS ap Attachments: R. S. Yates Proj. Mgr. 0230102 1 TOWOLDMONOQ45549 1. Specific Potential Problems Haw Materials Received H Threat . -p Probability Seriousness a. Biphenyl 1) Variation in quality a) Moisture contaminated b) Impurity level 2) Availability 6o 3 180 30 l 3 50 9 450 10 10~ 100 b. Chlorine Snlft Gas 1) Variation in quality a) Impurity level (Bromine) b) Sulfuric Acid content 2) Availability 100 100 5 10 9 900 9 900 9 45 10 100 c. PeCl3 1) Particle size too large or too small 2) Moisture contamination 3) Availability d. Lime 5 5 10 5 25 10 50 10 100 1) Availability 2) Moisture contamination e. Borocel 1) Availability 2) Moisture contamination 3) Particle size too large or too small 5 5 5 5 10 10 50 2 10 10 50 9 45 5 50 Raw Materials In Storage a. Biphenyl 1) Moisture contamination 2) Storage tank freeze-up 10 10 100 10 3 30 0?30103 TOWOLDMONOQ45550 2. H Threat Probability Seriousness o 3. Chlorlnator Area a FeCl^ Mix Tank 1) Inadequate catalyst supply to ItS chlorlnator 5 10 50 Chlorlnators 1) Unstable product 2) Crude 1142 out-of-spec on Sp. Gr. 3) Inadequate biphenyl feed to US chlorlnator 20 20 10 10 200 10 200 10 100 4) Inadequate temperature control Intermediate Storage Tank 10 3 30 1) Cannot feed stills or head tank 2) Cannot maintain proper aging temperature 3) HC1 emissions Blow Tank 1) Cannot feed stills at required rate 2) Cannot control level in tank 3) HC1 emissions *) HC1 is not removed to desired level Off -gas system 1) Cannot control off-gas temperature 2) Drowning jet will not handle full HC1 load 3) High back pressure 4) Water in HC1 off-gas 10 10 20 10 10 20 10 10 10 10 10 3 30 6 60 8 160 8 '8 8 2 80 8o l6o 20 5 50 8 80 9 90 IP 100 0? 30104 TOWOLDMONOQ45551 3. Threat_______ _ Probability Seriousness o 4. Stills 1) Erosion and/or pluggage of reboiler tubes 30 10 300 2) Cannot maintain vacuum 10 10 100 3) Cannot meet forward flow color spec. 4) Cannot control temperature 10 10 10 100 8 8o 5. Absorbers 1) Cannot meet electrical property specs 2) Cannot feed desired rate thru absorber 20 10 10 200 10 100 3) Cannot meet free chloride spec 10 10 100 6. Therminci Furnace 1) Coll failure 2) Cannot provide adequate heat for stills 10 10 10 100 10 100 7. Housekeeping 1) Unable to achieve acceptable level 10 8 8o 0P30105 TOWOLDMONOQ45552