Document DvyepM019B2dr6wkMb7M1j2na

/ g i MI Tactisuy ' Insurance AssmxYrifix iiAim^nui Chicago 'sax fiiaxcikcu WESTERN REGIONAL OFFICE 300 WEST ADAMS ST. CHICAGO. ILLINOIS 60606 TELEPHONE Of 21 263- f 24$ July 15, 1970 American MaizerProducts Company 113th Street and Indianapolis Boulevard Roby, Indiana 46326 ATTENTION: Mr. R. W. Bales SUBJECT: FIA File Mo. 6523 RE: Proposed Installation of Shrink Film Packaging System Gentlemen: This will acknowledge receipt of one (1) copy each of Vapor Corporation Installation Manual Bulletin Mo. ID-100-24, Revision A and Monsanto Bulletin O/FF-15, "Therminol Applications Unlimited", transmitted by you under your cover letter dated July 10, 1970. This information refers to the proposed employment of a Vapor Corporation liquid phase heater in conjunction with Monsanto heat trans fer liquid, Therminol FR-1, as a heating system for reference installation. \' In our June 24, 1970 meeting held in our Office, it was indicated to you that of the alternate heating systems proposed, a steam heat transfer system was the most desirable and a liquid heat transfer system, the. least desirable, from a fire protection point of view. Subsequently, in the writer's letter to you, dated*July 13, 1370, only those requirements applicable to heating systems this Association deemed suitable were presented. ' . With regard to the information submitted, please be advised that the general arrangement of the liquid phase heater is acceptable, but formal approval of detailed working drawings pertaining to the unit by this Association will still be necessary. However, Underwriters' Laboratories, Incorporated Gas and Oil Equipment List indicates that Therminol FR-1 is a mixture of chlorinated, aromatic hydrocarbon liquids which forms .weakly combustible and explosive mixtures with air at temperatures of the-order of 291F., and has a closed cup flashpoint of 350r. and an ignition temperature of 1206F.. On this -- basis, then, we would require that the liquid phase heater be located in a separate, sprinklered noncombustible adjoin and that carbon dioxide, or at minimum, steam flooding, of thp heater fire box be provided. -yrr DSW 434936 STLCOPCB4087996 American Maize-Products Company Roby, Indiana 46326 July 15, 1970 -2 - Other requirements, outlined in the writer's letter of July 13, 1970, under the heading GENERA! would be applicable in this case as well. I trust this evaluation is sufficient for you to proceed in this project, but should you have any questions, feel free to call or write. -A V Very truly yours, FACTORY INSURANCE ASSOCIATION RAG/pm /?. (L . . R. A. Gonzalez District Engineer Chicago Field Office DSW 434937 STLCOPCB4087997