Document DvwVOMBe0dwnYzD1ka233g8g4

f A MERIC I UAL LIABILITY INSURANCE COMPANY REFORT OF INVESTIGATION - . THE FLINTKOTE C0:3>AKY - TILETEX iPLAHT McKinley Avenue Chicago Heights, Illinois y 4.' <1 1' By Leon D. Horowitz Chief, Industrial Hygiene Section I ENGINEERING DEPARTMENT WAKEFIELD, MASSACHUSETTS 11687 FK-284 i i m m i m m ' i n . ...................................... ... ACKNOWLEDGEMENT The author of this report wishes to acknowledge the courtesy extended to him of Ur. B.A. Opita, Plant Manager, and Mr. Fred Svansop, Assistant Plant Manager, during his visit to this plant on March 10, 196s. ' He also acknowledges the help given to hit?, during this study, of Mr. J, T. Grisn of the Chicago Office of Aaarican Mutual Liability Insurance Company. . PURPOSE To evaluate the control of the potentially hazardous dusts, asbestos, tale, and limestone at the floor tile manufacturing operations. Neither the visit of our representative under the terns of our policy nor the making of this report constitutes an undertaking to determine or varrant .that your premises or operations are safe. 1 CONCLUSIONS i i Airborne dust concentrations vere excessive in the Scrap Grinding Area and at the No. 7 Dry Mix Feed. ' * ANALYSIS OP EHVIR01KENTAL DUST l Air samples for dust count vere obtained in the Scrap Grinding Are* and the Dry Mix Feed hoppers of l'o. 1, 6, and 7 lines. The results of these dust counts are shown on the attached Air Analysis Table. The Threshold Limit Value {T.L.V.) of 14.0 million particles per cubic foot (mppcf) is based on the formulation of toxic mineral dusts going into feed mixtures. Although approximately 3 to 5 bags of pure asbestof are added to each batch at the feed stations, it is of short duration and the batch loadings are intermittently spaced rather than continuous. Soje investigators might apply the more stringent T.L.V. of 5.0 mppcf (or the newly proposed 2.0 mppcf). However, it is our opinion that the exposure observed docs not warrant such strict interpretation. Note that the three air samples which did not exceed the TLV of 14.0 snppcf vere * also close to or belcv the TJL.V. of 5.0 mppcf used for asbestos alone. ,_ DESCRIPTION OF PROCESS AMD DUST EXPOSURE . Dry Mix Feed to Tile Machines Number 6 and Humber 7 Dry Feed Mixers are loaded froa rav material paper bags through hinged doors at the top of the mixers. Two-inch slotted hoods at each end of each pair of doors provide 350 feet per minute slot velocity. Thus, the air movement at the front of the feed-opening is less than 100 feet per minute and is, therefore, inadequate to provide the required control of dust during dumping. -2- Ths* slots have been damaged by heavy bags, etc,, and are, therefore, restricted at several points, The Dry Mix Feed for the Chip Kanufaeturins Line (Specialty Lint) is controlled by a Urge enclosing hood with duct take off at one end with very low air move* ent into'the duct (200 feet per minute air velocity), therefore, providing .practically no air movement Gordust control at the feed opening when bags are dumped into the mixer. Scran Crlndlnr, Area All reject and waste tile are brought to this area in steel drums for grinding and eventual use in the tile manufacture. The drums art dumped, by mechanical means, into a hopper and belt-conveyed to a grinder after which it'is belt-eonveyed to bins at one end of the roam. Although some dust collection it provided, it is very, inadequate, The drum dumping created a greet deal of dust as docs the grinder, belt? conveyors, belt transfer points, and belt dumping into the bins. Employees do not wear dust respirators during any of these operations. RECCMENDAT1CNS 1. The exhaust slots at Ho. 6 & 7 Dry Teed Mixers should be repaired and the - exhaust volume provided by the dust collecting system should be Increased. One method to provide adequate air velocity control of the dust created at this location is to provide slots at both sides of each feed opening instead of across two feed openings, This method is used at the Tile-Ter. plant in Hew Orleans where air velocities provided at a similar slat-type exhaust hood was ouch greater than at this location. The door hinged at the rear between the two slots on both sides effectively helps provide an air velocity away from the operator and dumping operation. Another effective method of providing adequate air velocity for controlling dust at this dump operation is to exhaust air directly from the mixer whenever the doors are opened. This would provide an inward movement of air which could effectively prevent the dust from rising up to the operator's breathing sone, 2. Although dust counts were not excessive at the .Dry Mix Feed dumping operation ' for the Chip Manufacturing Line, exhaust ventilation at both dump hoods should be improved. This would require an evaluation of-the dust collecting system . which is not providing adequate air movement and a better hood enclosure. The hood opening should be made snullor so that the inward air movement provided by an improved dust collecting system would be most effective at the source`of dust contamination, namely at the feed opening of the mixer, 3. It appears that a new dust collecting system oust be provided at the Scrap Crinding Operation. The drum dump hopper must be completely enclosed end ventilated to prevent dust; from escaping to the room air. All belts must be enclosed and prwided with exhaust ventilation to prevent dust escape to room air. All belt^ transfer points must be redesigned to prevent spillage -3and exhaust hood enclosures oust be used et these points to prevent escape of dust to the room atmosphere. The grinder oust be enclosed or provided with exhaust ventilation to prevent atmospheric contamination. rhe bins oust also be nted to the dust collecting system. , This dust' collecting system should include a cloth bag-type dust collector with ' automatic shaking device and provisions to return collected dwt to the mami' . facturing process if so desired. Exhaust air must be discharged to the outside, 4^ All operators exposed to dust concentrations which exceed the established T.L.V. must vear only respirators approved by U.S. Bureau of Hines for pneumoconiosis dusts. A respirator program, to maintain and keep individual respirators clean, must be instituted. 5. Annual (as well as preemployaent) chest X-rays (14" x 17") must be made on all employees working in toxic dusty areas. 6. Housekeeping must be nrinttintd In the Mixer Feed areas ms veil as the Scrap Crinder Area. i itfcHltfillMiiln.nl i iiM U ttH l !>ATF. 3-10-69 PUNT Fliwtkote-Tiletex Plant _ LOCATION _gyiwlHL_Ave.. Chicago Heists. .9 s^ Dim Atn-A.n.U*S{!. TABLE Location' and Event* Asbestos, Talc. Licesto Mixture Concentration -___ IQ 10 Breathing /.one Scrap Grinding Area 26.7 * m BC-15 sN-16 TM BN-25 1I BN-2 6 lo General Air Scrap Cringing Area . 10 Dry Kit* Teed - No. 6 10 Dry Mix Peed No. 7 Manual Shoveling in Calendar * 10 No. 1 Line Calendar Roll 10 No. 1 Lint t>rv Mixer (Room) 27.0 5.3 . 19.3 * 2.C A.C .. * - Threshold limit Volin A--Milligrams pet Cubic Meter B--PortsP**, Million C---Million Particle* per Cubic Foot - 14.0 mppcf ** Exceeds T.L.V.