ASBESTOS TESTING INC.
5205 NOYES AVE, CHARLESTON, WV 25304 (304) 925-6795 October 23, 1986
Erik A. Osby Industrial Hygiene Dept. Union Carbide Corporation P.0. Box 2831 Charleston, WV 25330
The following bulk insulation analysis results pertain to samples received on 10/21/86. All bulk insulation analysis is performed in accordance with EPA recommendations concerning analysis of bulk insulation using Polarized Light Microscopy.
ANALYSIS RESULTS
Sample #1
N.D.-Asbestos 1%-Mineral Wool 5%-Ce11ulo s e
94%-Clay
Sample #2
N.D.-Asbestos 1%-Mineral Wool
99%-Foam Glass
Sample #3
5%-Asbestos (Chrysotile) 10%-Cellulose 85%-Foam Glass
S amp 1e #4
8 5%-Asbestos ( 5%-Amosite) (80%-Chrysotile)
15%-Clay
Sample #5
40%-Asbestos (10%-Amo sit e) (30%-Chrysotile)
60%-Clay
Sample #6
15%-Asbestos (Amosite) 85%-Clay
Respectfully submitted
_John S. Ferrell Industrial Hygienist
A0400>
UCC 008985