Document DvoD0d9Zoaa4wQamYGm2rEdLQ
w
ii l
; i; ii;; ij
M H'
'i W-.
*{ {,{
f Mr
liiiiii
Heating Systems oiTSandd Gas
Ray Oil Burner Co.
Since 1872
1301 San jose Avenue San Francisco 12,-Cal.
_n
Atlantic Seaboard Division
^ttnyF^TAY--*
629 Grove Street
Jersey City 2. N. J.
There Is a RAY Burner for every Heating Purpose.
RAY FORCED DRAFT PACKAGED BURNER
__ A factory assembled unit readily applied to Scotch Marine type boilers of proper design for fully automatic operation on
' oil, gas or combination gas-oil. The combination gas-oil unit includes a rotary oil burner,
ttSySKBBw integrated ring type gas burner, secondary air control with a
:flHaBnSK|flj forced draft fan, windbox, refractory support ring, completely
flg. wired control panel and pre-piping completely factory as
sembled for quick and easy installation to the boiler.
Oil components may be selected to burn any grade of oil
FD-ARC Size #6 fully with the secondary air control providing increased efficiency
automatic, combination gas-oil, Forced Draft
even with the difficult-to-burn catalytic residual #6 fuel oils.
Packaged Burner.
From 59 to 456 certified output horsepower.
RAY COMBINATION OIL-GAS BURNERS
ARC-144 Model SO for heavy oil and Low Pres-
sure Gas
Typo PC for OH and Low Pressure Cos
Type AR-HH Combination OH and High Pres
ewe Gas
ARC-MODEL 50. Consists of a: rotary type oil burner of Ray conventional design coupled with a gas housing for low pressure gas, from 2 in. WC to 10 in. WC. The gas burner parts provide for the introduction of gas in a manner which,
fully utilizes the energy in the high pressure air supplied by the rotary burner fan. Gas and primary air are intimately combined, in two stages, before mixing with
the secondary air which is introduced through a vaned annular opening concen tric with the nozzle. Change-over requires less than one minute. Available to bum
any grade of oil in 10 sizes with capacities to 31,500,000 Btu/hr. TYPE HN for gas pressures above 1 Ib/sq in. may be used alone or in combina tion with a Ray Oil Burner. Built in eleverf sizes; in capacities to 43,000,000 Btu/hr. TYPE PC. Combination gas-oil burner pf the pressure atomizing type. Available in
three sizes with capacities from 560,000 to 2,500,000 Btu/hr.
RAY DOMESTIC AND MARINE BURNERS
Steam Turbine Drive,
Fully Automatict Type
Type TG, all grades oil. Tested and approved for
Ray Warm Air OH Furnace
Jp, ft or lighter oil
U. S. Navy Service.
RAY PRESSURE ATOMIZING OIL BURNERS Fully automatic for No. 2 oil. or
lWigAhRteMr. AAICR oFrUDRCN;ACcaEpSacBituieislt 1intofiv1e8sgizaellso,nwsitpheirnhpouutrc. apacities of 105,000; 14.n0o, rm2R3A0,Y00O0;IL35W0,A00T0E; R45H0,E00A0TEBRtuS. Four sizes. Capacities: 35, 45, 60 and 75 gal. M,axi.mu,,m,-
recovery rates: 100 to 240 gph.
1510
Heating Systems SSgu
Ray Oil Burner Co.
Since 1872
1301 San Jose Avenue
, Atlantic Seaboard Division
San Francisco 12, Cal.
629 Grove Street
Distributors in All Principal Cities of the World
Jersey City 2, N. J. Consult your local Telephone Directory
li Products: A complete line of Horizontal Rotary and Pressure Atomizing Oil Burners;
Combination Oil-or-Gas Burners; Industrial Gas Burners; Forced Draft, packaged
Burners; Oil Burning Water Heaters; Warm Air Furnaces, Commercial Ranges.
Type AR-144 Size 10 for
tNo. 6 oil. Available in
10 sizes from to HO gph. Fully automatic.
Fully Automatic Type AR-IS4, for No. 6 oH.
1 to 1000 Boiler hp Type AG. Manual, Semi-au tomatic control.
Type ARJP, Fully Au tomatic for heavy oH where gas for ignition not available.
RAY HORIZONTAL ROTARY OIL BURNERS
Built in fully automatic, semi-automatic and manual types;
in sizes from 1 to 1000 Boiler hp; to burn all grades of fuel oil.
laQ ftS_tteot_a_r,n_bKd_e_aai_trnndgn_m_re_oc_do_em.-l.-s.-m--i-en--n-c--dl*ue-ddJefroburuowtuhsi eudiwirreehcecvrteaonatdhebDretlithadnriv5e0s--orth6e0
Cycles AC, or only DC is available. Types for straight elec
tric or straight gas ignition; pump or gravity feeds. Direct
drive types include a steam turbine driven model.
DuA--alll Pf_u_u_lmmljyDpaauntodmRaetiscetrimyvpopeeirls,
fior nheavy oonil with the Ray
iVncISorCpOorSaItTe Yth"VeaRlvaey,
a patented, exclusive feature which automatically meters the
TvveBR-Ul.BdtDrive, correct amount of fuel at all times, regardless of changes in
Fully Automatic. 100 gph.
$14 to
viscosity of the oil due to temperature variations. All larger sizes employ dual ignition system, consisting of dual high-volt
age transformers, dual electric ignitors and dual gas valves.
Fully automatic sizes 9 and 10 include as standard equipment
electronic pilot and flame failure control.
Oil Capacity U. S. Gallons
Max.
3 4 38 8 18
Equivalent Boiler HP
Min.
3 3 9 25
Max.
9 12 25 56
Equivalent Lbs. Steam
Generated
Min. | Max.
110 325 110 430 325 865 865 1950
Heat Capacity
Input Thou. Btu Oil or 1000 Btu Gas
Min. | Max.
140 140 420
1120
420 560 1120 2500
Equivalent Sq. Ft Steam Radiation
438 438 1310
3500
1310 1750 3500
7900
0.5 2.5 0.5 2.5 1 2.5 25
2 2 3 7
8 GO 290
75
8 60 290
75
8 110 290
150
16 230 580 300
375
375 375 750
234 1170 234 1170 469 1170 938 2350
4 11 5 15 8 22
13 17 27
35 460 1250
600
50 580 1720
750
72 930 2500 1200
1650 2250 3300
1870 2350 3750
5170
7030 10,300
10 33 12 50
15 67 25 100
35 40 50
85
110 1150
3800
165 1400
5800
225 1720
7750
335 2900 11500
1500
1800 2250 3750
4950 7500 10000
15000
4690 5620 7030 11700
15500 23400
31400 46900
NOTE:
35 150
50 210 75 320
120 165
250
500 4000 700 5800 1000 1 8700
17400 24400 37000
5250 7500 11250
22500 31500 48000
m- issible, under depsiioraubiuletwcounudpityiounssp, etoanocpecroantediatitohnisghoef rdrraatfetsa,nodr afudrvniasaceblveoulunmdeer.reIsttrmictaeydbceopnedri-
tions, to operate ai reduced rates.
Heating capacities are based upon 150,000 Btu per gal of oil for rotary burners and 140,000 Btu per
8al of oil for pressure atomizing burners and upon an overall boiler efficiency of 75 per cent.
1511