Document Dvmn88X1np986BojnwK8pD14

loa*oiiag rofian but ||}f^ 5)^<vWi oo wiiti lonpt Win (OlbMlw grratironUIng tulgru t f In pwtt pfonta hovmp two or more oltomotors, porollol ooeroffon (S on overydoy act. When hro rmchlnes ore syn. chronlzed tome Indication It needed to show when nciuu. ' In Hep, to o voltmolor, tompi or o tynduotctn What the Synchroscope Voltage, frequency and phote to. be satisfactory, requires generators tems. The synchronising-dark method, rolatlonrhlp mutt match when alternatori and cystems are of similar electrical characteristics and prime movers with speed characteristics that are alike. with voltmeter, lamps or ifnehrescopq can use the same potential Irani(amen' provided (or the regular metering Thli Alternator* in Parallel. Two poly* additional load Is applied only doHnj' synchronized. James Wilton, phase oo generators, to parallel, must the syuchtoniaing period, and does ost electrical engineer, tells how have equal voltages, frequencies that notch, the some phase rotation, and affect the Instruments' accuracy lot'. metering. one Instrument sums up all proper phase relationship- Phase rots* tions are set equal at installation, and values except voltage. He ex the process is called "phasing out." An ae voltmeter indicates voltages, but a plains the operating princi check is also needed to determine when they are reselling maximum values In ple of several synchroscopes an Individual cycle. This lost test can he mads with either lamps or voltmeter, but values are not so good with either medium as with & synchroscope. The only definite indication given by lit ah ALtuutATtNO-cunaKf/r power cither lamps or voltmeter. Fig. 1, is that plant with more than one generator, the the incoming alternator is passing the essential Instruments are voltmeter, em* point of synchronism---or li in step. If meter and synchroscope. There are also . the lamps are connected so they are some helpful but not indispensable as* burning at the point of exact tyn- sUtaata like the wattmeter, power-factor chronism -- ijrnchronUing bright -- lha indicator and frequency meter. Before considering the synchroscope, let'a glance at the functiona of voltmeter and ammeter. eye cannot distinguish the instant of maximum brilliancy. For the method called synchronising dark, the dark period is shorter then the bright Yet the Voltmeter end Ammeter. To hold cor* reel voltage, every plant must have evailable at least one voltmeter. In ad* ditiou, each generator must have an ammeter to measure output current be* cause the amount determines the heat* fog of the machine. The heating in turn limits the total load that can be safely carried. Moat power plants, for over-eli economy end operating continuity, have more than one generating unit To carry the common load, these units are usual ly operated in parallel. TMs operation, eye cannot tell the exact point of no* current through the lamps, which Is the point of synchronism. If the voltmeter it used on the equiva lent of synchronising bright the indica tion, properly interpreted. Is better than with lamps. If the voltmeter Is con* nected for the equivalent of synchronis ing dark, the point of synchronism Is not clearly indicated because Its pointer Is at xero on the Insensitive end of the scale. Synchronising bright with either voltmeter or lamps requires a special transformer except on low-voltage sys Synchroscope Operation. To parallel one ac generator with another, the syo*. chroscope clearly indicates every eec& lion that the operator needs to know; except exact voltage. Although this is-. strument usually has only a single mark at top tenter end Slow and Fail with an arrow above exeh word, it shots, whether lha incoming generator Is nta- alng at the aame frequency as tbo has or the other generator but not In sp*; chjunfom with it. The synchroscope \ also shows whether the incoming go*. erator is running slower or faster, at . whether the geatrotora are in syn chronism. By the term synchronism-- ; in step--we mean that incoming genera* tor and bus are et the tame frequency,; nd that voltage alternations of both _ have (he same value and polarity at ths same time. These Indications give Informatics . for the preliminary operation* of par* alleling a generator with a ruftolag j plant, and enable the operator to eJos* : the generator switch without shock *0 ' the system. This It particularly lopor- ; tant on lower.frequency stcam*turbls plants since a small error causes ls^P swings of power to pull the incombf alternator into synchronism. Tb** swings place unnecessary electrical sod , mechanical strains on equipment. Although synchronizing lamps are w* really necessary, many plants lostsll ( H 1144) POWER March l**l chroscopes, Fig. 3. Its operating prin ciple is comparatively easy to demon* Sirota. The rotating armature is ener gized by circuit A through coils P and Q in series with a reactor and a resist ance respectively. Col) P circuit is highly inductive, due to the external re actor, causing current in the eoil to lag nearly 90 deg behind the voltage of circuit A. Coil circuit Q with Its ex ternal resistor, is but slightly inductive so current in that coil is very nearly In phase with the voltage of circuit A. The equivalent ot a true 90-deg current difference for these armature coils is ...TO, dttquombted view at on iron-rone synchroscope uses o stationery 2-phosc obtained by shifting them slightly from I^ermofwra wHK distributed winding. The vane is octuated by the resultant Hux. a true right angle to each other. This produces a smoothly rotating magnetic field In the armature structure, and nd How It Works causes the pointer to show the true phase relationship between circuits A and 0. Circuit of coils F Is highly inductive because of the iron field poles, end Its to addition to a eyochroscope. boro brightly when the pointer la bottom and dim gradually ai U * toward the top mark, where the i are completely dark. In this way, perator has a constant check on faehroscopo and its connections, schroscopo operation depends on of the following methods: (1) .phase bipolar synchronous motor to excitation, Fig. 2, 3, . 5 and fttype works by a-2-phase split of one of tho synchronizing voltages (2) Vane actuated by a resultant Box, Fig. 6 and 7. This method works by a 3* phase split of both synchronizing volt ages. (3) Electrodynamometer move ment, Fig. 9, similar to a wattmeter's. Methods (1) and (2) ore applications of the rotating field. Rotating fleW. The split-phase bi polar synchronous motor with ac exci tation and the rotating armature Is one of the oldest types of split-phase tyo* current la nearly 90 deg behind the voltage ol circuit B, whose magnetism is oscillating in value, end fixed fo position in relation to poles F. The armature rotating field coincides with ihst of the field poles, holding the armature end Its pointer. Thus they move clockwise or counterclockwise at a rate corresponding to the difference In frequency of circuits A and 8. If frequency of the circuits is tha same, the pointer comet to rest at the post* RtOCtor- _ rr if i J______ LJ !1 {P t _____ -U ------- -k-------------B - i' SpItf-phaM rotar end bipolar syn- rivmcope with a revolving orrooture 'OW8! . March IV, <r -a -- - This stator combines on ormotvra bnd flold windings; both stationery Distributed winding on the stator with o phose-shlft circuit Is shown (W| 77