Document DvbLVOJR83JVd7rapBRnQXpM4
John A. Jurgiel & Associates, Inc
September 12, 1934
lot: C3KCOUMC 3*lV 3T LOUIS, Ullloutl l]UI 13141 307*7404
Mr. Don Cehner Insulating & Materials Corp. 1042 Central Industrial St. Louis, Missouri 63110
Dear Don:
As part of MPO operations in the SRU vessels T-4809 and T-4809 were striped of insulation by IMCO. In support of this removal Jurgiel .and Associatescollected air samples on September 5, 1984 to determine fiber release during the.removal.
The four workers removing the insulation had been trained in asbestos removal and wore the required protective equipment. The removal area was secured with asbestos warning tape and portable warning signs. The insulation was wet d :wn before removal and during clean-up activities.
Results of personal and area samples i..iicated that removal procedures were effective in controlling fiber .release. The. results'.of. our. monitoring Is contained in .the. attached table... A11 . samples -were well., below the OSHA standard of' 2 fibers - per cubic centimeter.'
Should.you have any questions please feel free to call.'
JttWo
Doug&as N. Nimmo Certified Industrial Hygienist
cc: V. J. Grizzel (Shell Oil Company)
LAM 019548 ABS-000359
Sample Number Time
on - off
SRU-1 1246-1430
SRU-2 1250-1555
SRU-3 1233-1555
SRU-4 1257-1554
SRU-5 1500-1552
AIRBORNE FIBER CONCENTRATIONS DURING INSULATION REMOVAL ON VESSELS T-4808 & T-4809 SRU September 4, 1984..
Location
_ placeing insulation into bags
North West Corner of. controlled area (upwind)
Inside controled area (downwind)
South Side of Controled area (downwind)
* general -clean-up
Fiber Concentration
. f/cc 0.007
N.D.
N.D.
0.009
N.D.
=None Detected
LAM 019549 ABS-000360