Hazardous Materials
agency: Occupational Safety and Health Administration, U.S. Department of Labor.
action: Advance notice of proposed rulemaking: request for comments and notice of an>nformal public meeting.* *
SUMMARYrThe Occupational Safety and Health Administration (OSHA) (the Agency) is planning to revise its safety standards concerning hazardous materials which are contained in Subpart H of 29 CFR Part 1910, 1910.101 through 1910.116. The existing hazardous materials standards cover safety hazards associated with compressed gases: flammable and combustible liquids including those used in spray finishing or dip tank operations: explosives and blasting agents: liquefied petroleum gases; and anhydrous
nonia^^ *he purpose of this notice is to solicit information regarding the content scope and format of a complete revision of Subpart H. This information will also be used by the National Institute for Occupational Safety and Health (NIOSH) winch is seeking to supplement its safety research in the area of petroleum refinery maintenance. In addition, this notice announces the scheduling of an informal public meeting to give the public on opportunity for making oral presentations of comments and information regarding the issues discussed here.
dates: Notice of intention to appear at the public meeting scheduled below must be received by March 13.1961.
The informal public meeting will be held on April 8 and 9.1981.
The written information requested in this notice must be submitted on or before July 30,1981.
addressess: Send notices of intention to appear to Mr. Tom Hall, Division of Consumer Affairs. Room N3635. U.S. Department of Labor. Occupational Safety and Health Administration. 200 Constitution Avenue. N.W., Washington. T).C. 20210. (202)523-8024.
The informal public meeting will be ..eld in the Auditorium. Frances Perkins Department of Labor Building, 200 Constitution Avenue. N.W.. Washington. D.C. 20210.
Written comments requested in this notice should be submitted, in
quadruplicate, to the Docket Officer, Docket S-013, Room S6212. U.S. Department of Labor. Occupational Safety and Health Administration. 200 Constitution Avenue. N.W., Washington.
D.C. 20210. (202)523-7894.
FOR FURTHER INFORMATION CONTACT:
Public Meeting:
Mr. Tom Hall. Division of Consumer Affairs, at the address above, (202) 5238024.
Directorate ofSafety Standards Programs:
Mr. Glen E. Gardner or Ms. Joanne E. Slattery. Directorate of Safety Standards Programs. Office of Fire Protection Engineering and Systems Safety Standards, Occupational Safety and Health Administration, U.S. Department of Labor, Room N3463, 200 Constitution Avenue, N.W.. Washington. D.C. 20210, (202) 523-7225.
SUPPLEMENTARY INFORMATION:
Background
The present OSHA standards covering safety hazards associated with hazardous materials are contained in Subpart H of 29 CFR Part 1910. 19mm through 1910.116. The hazardous materials addressed in Subpart H include compressed gases: flammable and combustible liquids including those used in spray finishing or dip tank operations; explosives and blasting agents: liquefied petroleum gases: and anhydrous ammonia. These Subpart H standards became effective on August 27,1971, after promulgation under Section 6(a) of the Occupational Safety and Health Act of 1970 (the Act), 29 655(a). Section 6(a) of the Act authorized OSHA to promulgate standards based on national consensus standards such as those published by the National Fire Protection Association (NFPA) and the American National Standards Institute (ANSI), and on established Federal standards.
Several factors indicate to OSHA that a comprehensive revision of its Subpart H standards may be necessary. One factor is that since the original promulgation of OSHA standards. NFPA and ANSI have revised and updated their standards. OSHA has been petitioned by these organizations and other interested persons to adopt the more recent versions of these standards or to make other changes to the existing standards.
Another factor concerns the possible need for extending coverage to some industrial operations that are not currently addressed in Subpart H. For example, current OSHA standards may
not adequately address significant hazards associated with oil refineries, chemical processing plants, or combustible dust processes.
OSHA also recognizes that since the
adoption of Subpart H in 1971, there have been advances in technology and industrial practices associated with hazardous materials. These changes may have created a need for revising the present hazardous materials standards to better address current safety problems.
In addition, although OSHA has already revoked many public and property protection provisions in its standards which were not directly relevant to employee safety and health (43 FR 49728: October 24.1978), OSHA still feels that there is a need to revise these hazardous materials standards so that they more directly address
significant employee safety hazards. Finally., this advance notice is another
step in the Agency's continuing program of using a common sense approach by streamlining and simplifying standards while focusing on the more serious workplace hazards. In this regard. OSHA has already undertaken the comprehensive revision of its fire protection standards (Subpart L of 29 CFR Part 1910: 45 FR 60656 (September 12.1980)) and its electrical standards (Suhoart S of 29 CFR Part 1910: 46 FR 4034 (January 10,1981)).
For these reasons. OSHA has concluded that a comprehensive revision of its Subpart H standards may be necessary to provide more effective protection for employees who work with and around hazardous materials which pose a risk of fire, explosion, acute exposure and other safety hazards. Any rulemaking proceeding to revise Subpart H will be conducted in accordance with Section 6(b) of the Act (29 U.S.C. 655(b)) and 29 CFR Part 1911. and will provide adequate public notice of and opportunity to comment an proposed
changes.
Comments and Information Requested
Through this advance notice. OSHA invites interested persons and organizations to provide written and oral comments relating to the need for and content of a Subpart H revision. In particular. OSHA invites comments regarding any needed changes, additions or deletions to Subpart H und information in response to the questions
below. OSHA also invites comments
pertaining to any economic considerations (including, but not limited to, costs) and environmental impact regarding the questions posed in thisnotice. OSHA further requests that
CCR 000000206
Federal Register / Vol. 46, No. 15 / Friday, January 23. 1981 / Proposed Rules
7693
: available injury data be provided re a 'able.
A revu ,.i of OSHA'a hazardous ials standards may have a
ncant economic impact on a itantial number of small entities, articulariy small businesses, in ccordance with the provisions of the uiatory Flexibility Act (Pub. L. 99: 94 Stat. 1164 (5 U.S.C. 601 et set?.)), >5riA invites information regarding the conomic impact which any of these , templated changes to Subpart H . ht have on small businesses, Eluding, but not limited to, compliance, porting and recordkeeing costs. OSHA i requests comments regarding : matives which would minimize the wnomic impact on small businesses vhile at the same time accomplishing - objective of protecting worker safety
health.
wSHA realizes that this notice ddresses a large amount of material,
vever. the Agency anticipates that rested persons and organizations \ . concentrate their remarks on those trees of concern to them. OSHA also n^cipates that the information received a i provide OSHA with some guidance ) he sequence in which the hazardous nateriala standards should be revised or
1vc1ot
" nowj above, NIOSH is ) ;pating with OSHA in this niormation gathering process. Material concerning petroleum refinery i intenance is of particular interest It s ie intention of the Division of Safgety Research, NIOSH. both to
develop standards recommendations to i ist OSHA and, simultaneously, to i relop safety guidelines for petroleum refinery maintenance. Therefore, a copy of all relevant communications received
espouse to this notice will be f warded to NIOSH for it use.
it should be noted that safety
requirements concerning the storage and h idling of anhydrous ammonia. ; sently 1910.111, will not be Qiacussed in this notice. Revision of the anhydrous ammonia provisions was the $ bject of an April 23.1976, advance r ice oi proposed rulemaking in the 5 ~Jerai Register (41 FR 17227).
Additionally, grain handling facilities v-'I not be specifically addressed in this r ice. Grain handling facilities were the s.- jject of a February 15,1980, request
for information published in the Federal Poster (45 FR 10732). Comments and i DrmaUon received in response to the c iydr ammonia and grain handling f 'itife. ..otices will be considered in <. . development of standards for these c es which may be included in Subpart l
The remaining standards in Subpart H will be discussed in this advance notice. Discussion will be limited to safety
issues and will not address health issues. OSHA invites written or oral comments and information regarding the
following general and specific issues concerning Subpart H.
A. CeneraJ Issues: Several issues have been raised which are common to a number of the hazardous materials standards contained in Subpart H.
OSHA invites comments on these general issues which are set forth below.
(1) Should OSHA use a new format in
revising its hazardous materials standards? On September 12,1980,
OSHA published in the Federal Register (45 FR 60656) a revision* of its fire
protection standards contained in Subpart L of 29 CFR Part 1910. Revised Subpart L utilizes a new format consisting primarily of performance, or goal-oriented mandatory standards.
These performance standards are accompanied by several nonmandatory
appendices which contain compliance guidelines intended to provide
compliance flexibility. Compliance can be effected through the means suggested
in the appendices or in some other manner as long as the level of performance required by the standard is met Additionally, Appendix C to
Subpart L contains a Ust of applicable references intended to provide the employer with additional information which will be helpful in the implementation of the mandatory
performance standards. OSHA is
considering the use of this format in revising its hazardous materials standards. Comments are invited on the advantages or disadvantages of such a format
(2) Do particular provisions of Subpart H need simplification or clarification? For example, would it be simpler to have all of the definitions applicable to
Subpart H contained in one section, or would it be simpler to continue to have applicable definitions accompany each section to Subpart H? Comments which identify other Subpart H provisions in need of simplification or clarification are invited as well as suggested corrections to such provisions.
(3) Are there gaps in the coverage of Subpart H with regard to both the hazards and types of workplaces
covered? For example, current OSHA
standards may not adequately address significant hazards associated with oil refineries, chemical processing plants, or combustible dust processes. OSHA invites public comment on these issues by posing the following questions: (a)
what are these significant gaps: (b) how can OSHA best eliminate these gaps:
through the revision of existing standards, the development of new standards, or both: and. (c) should new
standards apply to all industries (horizontal standards) or only to a particular industry (vertical standards], or should a combination of both types of standards be used?
(4) Should OSHA expand the coverage of Subpart H in order to more fully address the problems involved with hazardous materials? Should OSHA also recognize and change the section titles? Such expansion and reorganization of Subpart H as envisioned by OSHA would include section designations for any new standards that are developed to cover gaps which exist in current standards.
The following outline for Subpart H is under consideration by OSHA and is being presented to solicit comments from the public regarding its content and the need for expansion, deletion, and
reorganization:
Subpact H--Hazardous Materials
1910.10 Scope and application. .102 Definitions.
Casas
1910.103 General requirements (including containers, storage, handling, and use).
.104 Liquefied energy gases (LEG). .105 Hydrogen. .106 Oxygen. .107 Acetylene. .108 Cryogens (cryogenic gases including
refrigerants).
Liquids and oxidizers
1910.109 Flammable and combustible liquids.
.110 Anhydrous ammonia. .Ill Oxidizing materials (liquids and
solids). .112 Corrosive liquids.
Solids
1910.113 Explosive materials (manufacturing, storage, handling, and use).
.114 Ammonium nitrate. .115 Fireworks. .116 Combustible dusts (metal and
organic). .117 Flammable solids. .118 Reserved. .119 Reserved.
Operations involving hazardous materials
1910.120 Grain handling facilities. .121 Spray application using flammable or combustible liquids. 122 Dip tanks containing flammable or combustible liquids. .123 Oil refineries. .124 Chemical plants. .125 Reserved.
Is the scope of this expanded version of Subpart H too broad? Should some of the subject areas be consolidated and are there any subject areas that should be eliminated entirely? Convenely. is
CCR 000000207
7m
Federal Register / VoL 46. Nxr. 15 / Friday, January 23. 1951 / Proposed Rules
' -* scope of this expanded revision of >part H too narrow? What other
nazardous materials should OSHA Include in Subpart H7
(51 Should OSHA require controls such as labeling or other means of
marking piping and hoee transfer
systems to prevent the inadvertent mixing of chemicals or other materials at loading and unloading points? What information is available on the number
of employee injuries and fatalities caused by the Inadvertent Tnixmg of chemicals or other materials at these points? What type of controls are
currently in use to prevent these
occurrences? How effective are such controls in preventing employee injuries and fatalities? What additional controls would provide greater employee protection?
(6) Should OSHA
specifically require special protective equipment for employees who repair piping containing hazardous materials? (See present OSHA requirements for protective equipment in Subpart I of 29
CFR Part 1910, particularly 51910.132(a).) For example, should
breathing apparatus be made available and ready for use during repair work?
Should fire-resistive protective clothing quired when repair work is
Pb.iorraed on piping which contains
flammable material? Should emergency ventilation equipment and, when necessary, a water supply and bose. be accessible and ready for use to dilute
vapors or liquid leaks that occur during repair work taking place inside of
buildings? Should OSHA require written emergency rescue procedures? What other measures should OSHA consider?
(7) Should OSHA develop standards for the hazards of in-plant piping
systems that use flammable premixed gases? How should OSHA define flammable gas? What test procedures should be used? What source materials
should be used? (8) Should OSHA require testing of
piping used for flammable, combustible,
or toxic gases or liquids? For example, should OSHA require an acceptance static pressure test on piping that is newly installed or has been repaired, to assure that the piping will not leak? If static pressure testing of piping were to be required, what test methods and testing equipment should be acceptable
to OSHA? (9) Should employers be required to
provide information and training to
th employees who handle or use m,, tals covered in Subpart H? Should
OSHA require material safety data sheets or equivalent forms for those
substances covered in Subpart H? What
information should be contained in these material safety data sheets, e.g..
manufacturer noma, chemical and trade name, physical and chemical properties, hazards? By what other means should
OSHA require employers to inform employees of hazards? What employee training should OSHA require? Is there a need for requirements in addition to those which would be created by the proposed Hazards Identification standard (40 FR 4412: January 16,1981)?
(10) What types of personal protective equipment and clothing should be .required for handling hazardous materials (e.g., gloves, full body clothing, boots, eye protection)? What specifications should be used and what test methods and pass/fail criteria should be applied to such equipment? Are specifications possible for broad industry application? What would be an
alternative to the use of specifications that would assure appropriate protection from specific hazards? What protective equipment and clothing are presently being used and how effective
are they? How oftem must equipment and clothing be replaced? What training should employees have is the use of protective equipment and clothing? How often should such training be provided? Should OSHA standards include provisions for a broad class or general use type of protective equipment and clothing for handling a class of similar materials? For which substances should protective equipment and clothing be addressed only on a substance by substance basis? Is further research on the question of protective equipment and clothing necessary for the materials or processes covered by this notice before suitable protection can be specified?
(11) What injury data is available concerning the storage, handling, and use of hazardous materials? What circumstances were involved in such
accidents? Were there control or safeguard failures, pipeling ruptures, uncontrolled sources of ignition, procedural errors, or the inability of personal protective equipment and clothing to prevent injury?
(12) Should OSHA require the use of monitoring devices for various hazardous materials which would indicate when an unsafe condition is beginning to develop? For example, a device which monitors the hazardous material-to-air volume ratio would serve as a warning when a hazardous atmosphere is being approached. OSHA
invitee comraents-on the types of
monitoring devices which, are available (both fixed and portable types) and on devices which are presenty being used
to monitor gases, vapors, and dost* Should these devices produce an
audible alarm? Are common monitoring devices available which are approved for use in hazardous (explosive) atmospheres? If so, when should OSHA require such monitoring devices? What degree of accuracy should be required of such monitoring devices?
(13) Should OSHA require planning for workplace disasters as a part of a written emergency action plan as addressed in the new 1910.38, Subpart E, as revised September 12.1980 (45 FR 60656)? Under what conditions? What type of training should be required for employees who will be affected by such plans? How often should such training activities be conducted? Should such plans require planning and coordination with outside resources such as hospitals, ambulance services, and police and fire departments to eiisure appropriate response to workplace disasters? Can allowances be made for an employer's inability to control performance of such outside agencies? Should OSHA encourage the development of community cooperation in planning for workplace disaster situations? If so. how?
(14) Should OSHA require communication devices such as radio, telephone, etc., to be available for emergency use by employees who work with hazardous materials while alone or in isolated areas?
(15) Should OSHA require some form of systems safety analysis such as failure mode and effects analysis for operations involving hazardous materials? If so. what sizes and types of operations should be covered?
(16) Should fire retardant coatings and mastics be acceptable under Subpart H with respect to protection against fire? For example, certain OSHA standards, such as 5 1910.106(d)(4)(ii), require walls to have a specified fire-resistance rating when used to protect employees from exposure to hazardous materials. Should walls having fire retardant coatings and mastics which afford a specified level of protection, be acceptable to OSHA as alternatives to fire-resistance rated walls? What criteria and test methods should be specified to evaluate the protective characteristics of fire retardant coatings and mastics? What field compliance techniques or devices are available to determine if the fire
retardant coatings and mastics are capable of providing the intended level of protection?
B. Specific Issues: In addition to the general issues discussed above. OSHA
invites comments on the following specific issues relating to hazardous
materials. (1) Compressedgas cylinders, (a)
Should OSHA develop inspection
CCR 000000208
Federal Register / Vol 4ft. No. 15 / Friday, january 23.1981 / Proposed Rales
7SS5
ocedures fcr compressed gas _ iinders? Sh uld cylinder inspection r me to be conducted in accordance
(he Hazardous Materials
jgulations of the Department of ;ansportation (DOT) (49 CFR Parts
171-179) and with Compressed Gas Association (CGA) Pamphlets C-fl and
-8 as prescribed in 1910.101(a)? (b) Should standards for compressed
gas cylinders be contained in Subpart H or should such standards be contained
i Subpart M, Compressed Gas and
ompressed Air Equipment? (c) Should OSHA standards include
quality assurance provisions for
ompressed gas cylinders manufactured utside of the United States? Should UOT approval of such cylinders be acceptable to OSHA? (d) Is there a need for standards /hich specifically address the use of impressed gas cylinders in hospitals
and laboratories? (e) Should OSHA develop
equirements for the handling, in-plant
ransportation, securing during use. and storage of compressed gas cylinders?
(f) Should OSHA require a color coding system for compressed gas cylinders that would serve to identify the contents? What type of system
should be required? ") Liquefied-petroleum gas (LPC). (a) aid MAPP (methylacetylene-
propadiene) gas be considered a
liquefied petroleum gas? Although MAPP gas possesses some of the same characteristics as LP gases (especially
the LP gas. propane) it does not technically conform to the definition in the National Fire Protection Association
(NFPA) Standard 56. "Liquefied Petroleum Gases. Storage and Handling." nor to the OSHA definition of LP gases in % 1910.110(a)(7). Consequently. MAPP gas is not
presently covered by a specific OSHA standard. A new section is being considered ( 1910.104 in the outline
discussed above) entitled "liquefied energy gases" which would include liquefied natural gas (LNG), liquefied synthetic natural gas (SNG). MAPP gas, and LP gases. OSHA invites comments concerning the appropriateness and
effectiveness of such an approach. (b) Should OSHA adopt applicable
provisions of the latest edition of the
NFPA standard for LP gases (NFPA 56}? The 1968 edition of NFPA 58 was used as the source for the present OSHA
standard for LP gases ( 1910.110) and
OSHA has not revised or updated this ' tundard since its promulgation in 1971.
c) Should LP gas-fired temporary ..jitters (salamanders) be tested and approved in accordance with the
American National Standards Institute
(ANSI) standard for gas-fired construction heaters (ANSI Z63.7)? Who should perform the testing? Should testing and approval by the American Gas Association (AGA) be acceptable?
(d) Should OSHA standards include maintenance provisions for LP gas distribution equipment? What maintenance provisions should be specified?
(e) Should OSHA incorporate applicable provisions of ANSI Standard B138-1. `'Design and Construction of LP* GaB Installations at Marine and Pipeline Terminals. Natural Gas Processing Plants. Refineries and Tank Farms." for all of general industry?
(f) Should OSHA adopt standards to cover aerosol container filling processes which use LP gases or some other flammable gas as the propellent? Are injury data available which would indicate a need for such standards?
Should OSHA use the provisions of the latest edition of NFPA 58 which apply to filling LP gas containers as a basis for any requirements pertaining to aerosol container filling processes? What precautions and special procedures are presently being used for filling rooms? What are proper procedures for disposal
of leaking containers? (3) Liquefied natural gas (LNG) and
synthetic natural gas (SNG). fa) Should OSHA develop standards for LNG and SNG? What source standards should be
used? What hazards need to be addressed?
(b) Should OSHA develop standards
for underground and above-ground storage of LNG and SNG?
(4) Cryogens. Should OSHA develop standards which address the safe handling, use. in-plant transportation, and storage of cryogens (gases compressed to a liquid state of extremely low temperatures)? Should cryogens be defined in terms of temperature alone or both temperature and pressure? Should OSHA develop design criteria for pressure vessels and other storage containers based on the extreme low temperature properties of
cryogens? (5) Flammable and combustible
liquids, (a) Should OSHA allow storage tanks for flammable and combustible liquids to be constructed of materials other than steel? What minimum criteria should these other materials meet? If
storage tanks were constructed of other materials, would there be an increased risk of leaks? What other hazards, if
any. would be presented by the use of other materials?
(b) Should certain industries which are presently exempted from the OSHA standard for flammable and combustible liquids as specified in 1910.106 (j) (6)
be covered by a revised OSHA standard for flammable and combustible liquids? What requirements should be provided to cover these industries?
(c) Should OSHA require safety coated (plastic-coated) glass containers to be used for the storage of flammable and combustible liquids where plain
glass containers are presently permitted? Should OSHA permit greater
quantities of flammable and combustible liquids to be stored in plastic-coated glass containers than those which are presently premitted in plain glass containers? What should the maxiurn quantity be? Should OSHA continue to permit plain glass containers
and then, as an alternative, permit greater quantities to be stored in plastic-
coated glass containers? What types of accidents or incidents, whether they produced injury or not have occurred with plain glass containers that might
have been prevented if plastic-coated glass containers were used? What criteria for coating glass containers are already available and bow were they developed? What criteria should be developed?
(d) Should any container acceptable to DOT for the shipment of flammable and combustible liquids also be acceptable to OSHA for the storage of flammable and combustible liquids in the workplace? If so, what limitations should be placed on the use of the
containers and their storage facilities? What hazards can be expected during the transfer of flammable and combustible liquids from storage containers? Is-there a hazard in
transferring flammable and combustible liquids from shipping containers acceptable to DOT, to storage containers acceptable to OSHA7 What
hazards are associated with the storing of flammable and combustible liquids in the shipping containers? Which specific operations involving storage, handling,
or transferring of liquids, can be considered more hazardous than others and why? What problems can be encountered during the storage and handling of non-metallic containers? Are there significant hazards associated with the generation of static electricity during the transfer of flammable and
combustible liquids from non-metallic containers? What procedures are used
to dissipate the static electrical charge normally associated with the transfer of
flammable and combustible liquids? Are sufficient charges of electrical energy generated and stored in non-metallic containers which can be later released
as a potential ignition source? What level of static electrical charge is necessary to ignite flammable and
CCR 000000209
7696
Federal Register / Vol. 46, No. 15 / Friday, January 23, 1981 / Proposed Rules
c fustible liquid vapors found in l insing areas and what distance can
this electrical charge be expected to travel if the conductor is: (1) the ambient atmosphere, or. (2) the rack or holding device that holds the container during
dispensing operations? Does the construction material of spouts or spigots (i.e. metallic versus non-meiallic) affect the dissipation of the electrical charge developed during dispensing of flammable and combustible liquids?
(e) Should QSHA limit vapor concentrations to a specific percentage of a liquid's lower flammable limit (LFL)
(also known as lower explosive limit (LEL)) when determining hazardous concentrations? If so. what should that specific percentage be for nonhazardous, cr Class I. Division 1, Class I. Division 2 locations?
(f) Should OSHA develop separate standards for the storage of flammable and combustible liquids in laboratories? If so. how should they differ from general storage requirements?
(g) Should OSHA permit the use of automatic closing nozzles with latch
open devices on Class I liquid dispensers (such as gasoline servicepumps) used in industrial occupancies?
omatic closing nozzles with latch _ jii devices are currently allowed on
Class I liquid dispensers in service stations accessible to the public when dispensing is done by the attendant ( 1310.108(g)(3)fvi)(b)} but they are not allowed in industrial occupancies.
Would spiilage increase if automatic closing nozzles with latch open devices were permitted in industrial occupancies?
(h) Should OSHA continue to require that all rebuilt or repaired nozzle valves be recertified as soecined in 1910,106(g)(3)(iv)(i)(2)? Why or why not?
(i) Should CSHA permit the use of military-type ''jerry cans" for the storage of flammable and combustible liquids? Under what conditions?
(j) Should CSHA recognize alternative flash point determination test methods (such as the Setanash closed cup tester)
in addition to those soscified in 5 1910.103(a)(14)?
(k) Should OSHA change the drainage requirements as orescribed in
19l0.107(b)(2J(vii) for outdoor storage facilities for flammable and combustible liquids? What should be required?
(l) Should OSHA change its definition a liquid as specified in . i910.106(a}(17) to exclude the more viscous liquids such as certain paints and coatings? What test method should be used for flash point determination of
such viscous liquids?
(m) Should OSHA continue to limit the size of indoor storage rooms as specified in $ I910.106(d)(4)(ii)? If OSHA
does not continue to limit the size, what
additional requirements should apply? (n) Should OSHA redefine flammable
and combustible liquids in order to exclude those water base liquids (such as water base paints) which have a flash point but do not have fire points?
Should liquids (such as wine) containing 24 percent or less alcohol by volume by excluded provided that the remainder of the liquid does not present a hazard?
What criteria and test methods should
OSHA use to define flammable and combustible liquids?
(3) Oxidizing materials, (a) Should OSHA develop standards which address the storage, handling and use of oxidizing materials? What source
materials should be used? (b) Would fire protection measures
and storage provisions alone be appropriate and adequate for protecting
employees involved with the storage,
handling and use of oxidizing materials? (c) Should oxidizing materials be
classified? In what manner should they be classified? What criteria and test
methods should OSHA use to define
oxidizing materials? (71 Corrosive liquids, (a) Should
OSHA develop standards which address the storage, handling and use of
corrosive liquids? What sources of information should OSHA use to
develop standards? (b) Should OSHA require the
employer to have special safety procedures for treatment of in-plant accidents involving corrosive liquids?
Should OSHA prohibit the use of plain glass containers and require the use of
plastic-coated glass containers for storage and handling of corrosive liquids?
fc) Should corrosive liquids be
classified? In what manner should they be classified? What criteria and test
methods should OSHA use to define ' corrosive liquids?
(31 Explosives and blasting agents, (a)
Should OSHA develop standards for the manufacture of explosives? Section
19*0.109 of the current OSHA Subpart H covers the transportation, storage, and
use of explosives and blasting agents, but does not cover the manufacture o: explosives.
Standards of the Bureau of Alcohol, Tobacco and Firearms (BATF) contain
requirements for the storage of explosives (Subpart J of 27 CFR Part 181, Sections 181.181 through 181.200): standards of the Department of
Transportation (DOT) contain
requirements for the transportation of explosives (49 CFR Parts 171 through
179): and, the OSHA Construction Standards (29 CFR Part 1926, Subpart U) contain requirements for the use of
explosives in blasting. It has been suggested that 1910.109
be revised to include provisions for the manufacture of explosives and to
incorporate the above noted standards by reference where appropriate. OSHA is interested in receiving comments concerning the usefulness and feasibility
of this approach. (b) Should OSHA develop a separate
standard for the manufacture, storage, and handling of fireworks? In the
alternative, should requirements for fireworks be more clearly delineated in the context of present standards for explosives?
(c) Should OSHA permit the transportation of blasting caps in the
same vehicle with other explosives when the safety Drocedures sDecified by DOT in 49 CFR 177.835(g) are followed?
(d) Should OSHA ever permit blasting operations to be performed during non
daylight hours? Under what conditions? Present OSHA standards (1910.109(e)(l)(v)) require blasting
operations to be performed only during
daylight hours. (e) Are present OSHA definitions for
"explosive" as specified in I910.209(a)(3l and "blasting agent" as specified in 1910.109(a)(1) technically
accurate? Are there other definitions which would be as accurate but would also be consistent with those of other
agencies, such as DOT? (f) When testing circuits to charged
holes, should OSHA require that
blasting galvanometers, which verify that circuitry is completed, be equipped
with a silver chloride cell which is especially designed for this purpose? Are there alternative batteries available
which are equally safe? There has been some controversy concerning this issue.
Some experts state that specifying the use of a silver chloride battery i9
necessary to ensure against accidental detonation of the charged holes. Other experts argue that specifying the use of
a silver chloride battery creates a monopoly market for this type of battery, restricts innovative technology, and needlessly excludes other types of
batteries which could be used without jeopardizing employee safety.
(9) Combustible dusts, (a) Should
OSHA develop standards in Subpart H which define and regulate combustible
dusts? If so. should various classes of combustible dusts be individually
addressed, e.g., metal, organic, plastic? Or would it be sufficient to develop general requirements applicable to all combustible dusts? What source
standards should be used?
CCR 000000210
Federal Register / VoL 46. No. 15 / Friday, fanuary 23,1381 / Proposed Rules
7897
(b) Should OSHA require specific dust control criteria for those industries whos n-facturing processes involve "ombuouDle dusts. e.g,, the
.larmaceutical industry and food
processing industry? Under what condition, if any. should explosion
venting be required? (10) Flammable solids. Should OSHA
develop standards for the use. handling,
and storage of flammable solids (such as camphor, potassium, sodium, and
phosphorus)? What source standards
should be used? What definitions and test methods should OSHA specify to accurately identify these substances?
(11) Spray application using flammable or combustible materials* (a)
Should ventilation requirements for
spray finishing operations presently contained in 1910.94(c) be
incorporated into a Subpart H standard for spray application using flammable or combustible materials? Confusion frequently exists when reference must
be made to to 1910.94(c) concerning
spray booth ventilation requirements when the other spray application
requirements are contained in Subpart
H. 11910.107. Would this confusion be eliminated if requirements for
ventilation and spray finishing were
contained in one standard? (b)' ild the requirement for a 20
foot q. .nee between a spray booth nd electrical equipment as specified in
1910.107(c)(2) be reduced to ten feet, and under certain conditions, five feet, to be consistent with the latest editions
of the National Fire Protection Association (NFPA) Standard 33. "Spray
Application Using Flammable and Combustible Materials" and the National Electrical Code. The 20 foot distance requirement was originally
adopted from the 1968 edition of NFPA 33. Would employee safety be adequate
at these reduced distances? (c) Should OSHA ever permit the
recirculation of air exhausted from a
spray operation back to the same spray operation? If so. under what conditions?
What precuations should OSHA require? Present OSHA standards ( 1910.107(d)(9)) prohibit the
recirculation of air exhausted from spray operations. However, recirculation is permitted by the latest
edition of NFPA 33 under certain conditions.
(d) Should OSHA permit open spraying, i.e., spraying outside of a
spray booth or spray room, as is
presently permitted in the latest edition of NFPA 33? If so, under what conditions
shoul HA permit this practice? (e) present OSHA ventilation
standard for spray operations
( 1910.94(c)(6)) requires specific
ventilation rates. It further requires that
ventilation must dilute solvent vapors to less than 25 percent of the lower flammable limit (LFL) (also called the
lower explosive limit. LEL). is compliance with the specified
percentage alone, sufficient to provide for employee safety? If not. what else should be required?
(f) Should OSHA ever permit the
placing of electric motors (approved for use in hazardous locations) in exhaust
ducts that are less than five feet in
length? This practice currently
prohibited by 5 1910.107(d)(5). Should this practice be allowed provided that:
(1) the motors are shielded from direct overspray; (2) the fan blades are
mounted directly on the motor shafi; and
(3) inspections, cleaning, and
maintenance are conducted on a regularly scheduled basis? Are there other precautions that are necessary?
(g) Should OSHA permit the use of
thin plastic or paper bags as protective
covers on sprinkler heads? It has been suggested that thin coverings on sprinkler heads would not alow the
activation of the sprinkler heads to any
significant extent and would protect the heads from overspray which could slow
their activation. OSHA is seeking any
data on the use of such protective coverings.
(h) Should OSHA permit the use of strippable coatings or kraft paper in
spray areas to facilitate cleaning? It has been suggested that the use of kraft
paper to cover exposed areas in spray operations facilitates cleaning and does
not significantly increase the Are hazard once it is covered with a thin coating of
overspray. Under what conditions, if any. should OSHA permit this practice to be used?
0} Should OSHA develop standards which specifically address the use of
water base finishes in spray operations?
Most of these finishes involve little or no hazard in the liquid state but leave
highly combustible residue upon the vaporation of the liquid easier.
(j) Should ventilation, requirements for powder coating operations be different from those for liquid spray operations?
For example, the latest edition of NFPA 33 addresses ventilation for powder coating operations by requiring Sufficient airflow to maintain the
exhaust duct at a powder concentration that will not exceed one half of the lower flammable limit or minimum
explosive concentration (MEC) of the powder in use as compared with 25 percent of the lower flammable limit
(LFL) for liquids. IF the MEC of the
powder has not been established, the
NFPA standard requires that the exhaust duct powder concentration be
maintained below &015 ounces per cubic fot (15 g/m*J. Does this approach provide an adequate margin of safety for employees?
(k) Should OSHA allow the use of spray buildings? A spray building is a detached building where only spray operations are conducted. What special conditions should be required for this type of building? Are the present OSHA requirements in $ 1910.107 unnecessarily stringent for application to spray buildings?
(l) Should OSHA change the title of 1910.107. "Spray Finishing Using Flammable and Combustible Materials/' to the NFPA title. "Spray Application Using Flammable and Combustible Materials." to be consistent with the Source standard as well as to eliminate confusion in the application of the standard?
(12) Dip tanks containing flammable or combustible liquids, (a) Should the
title of the present standard. 5 1910.106. "Dip Tanks Containing Flammable or Combustible Liquids," be changed to be consistent with the proposed title of the National Fire Protection Association (NFPA) Standard 34. "Standard for Dipping and Coating Processes Using
Flammable or Combustible Liquids?" (b) At present all dip tanks containing
flammable or combustible liquids are covered by 1910.106 without regard to the flash point of the liquid. Should OSHA limit coverage only to those
liquids with flash points below 200 degrees F, and to those liquids with flash points above 200 degrees F whose
temperatures are raised to within 50 - degrees F below their flash point? Would this approach provide adequate employee safety?
(c) Should the present requirements for dip tank bottom drains (S 1910.108(c)(3)) be revoked? It has been suggested that bottom drains are for the protection of the tank contents rather than for employee safety.
Additionally, it has been suggested that in the event of fire, draining the tanks may not contribute significantly to employee safety, and may actually decrease safety because draining the tanks results in exposing more residue laden surfaces.
(d) Should OSHA permit alternatives to its present requirement that overflow piping lead to a safe location outside the building as specified in 1910.108(c)(2)? Suggested alternatives include overflow piping which leads to a safe location inside the building or, instead of overflow piping, having a dike around the dip tank in conjunction with limiting
employee exposures! What criteria should be applied?
CCR 000000211
7698
Federal Register / Vol, 46, No. 15 { Friday, January 23. 1981 / Proposed Rules
(el Should OSHA ever permit the het of liquids in dip tanks to temK_,atures above their flash points? Under what conditions? Present OSHA standards prohibit the heating of liquids
in dip tanks to within 50 degrees F below their flash points as specified in 5 1910.108(c)(7). However, the latest edition of NFT?A 34 permits the heating
of liquids to their boiling points or to within 100 degrees F below their autoignition temperatures. Should OSHA revise its standard in this regard? If so, what additional requirements should be specified for ventilation and employee safety?
(f) Should applicable provisions of 1910.94(d) concerning ventilation for open surface tanks be incorporated into
the Subpart H standard for dip tanks? (g) Should present provisions
addressing hardening and tempering* tanks as specified in $ 1910.108(h)(1) be made applicable to internal quench tanks, i.e., fully enclosed tank systems
.used in heating-treating materials? (h) Should ventilation required for dip
tanks be based on a percentage of the lower flammable limit (LFL)? The
proposed NFPA Standard 34 would require that ventilation systems maintain vapor concentrations at or
belt 5 percent of the LFL five feet or mort jm the vapor source. If OSHA
adopts this approach, what type of monitoring should be used to ensure that the vapor concentration does not exceed specified levels?
(13) Molten metal operations. Should OSHA develop standards for operations involving molten metal? If so, what
problems should be addressed? What measures are available to minimize the incidence of steam explosions resulting from spills or the introduction of moisture into furnaces? Should OSHA require monitoring for carbon monoxide (CO) in areas of employee exposure
near furnaces to prevent employees from being overcome by acute
exposures? (14) Oil refineries, gas. chemical and
petrochemical plants, (a) Oil refineries, gas. chemical and petrochemical plants
have been modified to operate at higher output and with greater stroage capacity than contemplated in their original layout. Does improper spacing between certain equipment, resulting from these
plant modifications, contribute to
substantial safety hazards? Should OSHA propose general spacing requirements for equipment in refineries
and r1 'ts which are being modified or plan. What should be the basis for
these requirements? (b) Should OSHA require an
emergency action plan as addressed in new 1910.38. Subpart E, as revised
September 12.1980 (45 FR 60656) for all employees including contractors? What
specific elements should be contained in such a plan?
(c) Should OSHA require a "hot work"
permit system for types of work which may cause fire or explosion?
(d) Can some flammable vapor or gas
concentration (percentage of lower flammable limits) be specified as the upper bound at which regular electrical
wiring can be used without hazard to employees? What monitoring and ventilation should be provided to ensure
that the concentrations of flammable vapors or gases are kept below an upper
limit? What level of accuracy should be required of the monitoring equipment? What monitoring equipment is currently available or in use?
(e) Should OSHA require special safety procedures for employees, including employees of outside
contractors, for work performed during breakdown process repairs, refinery turnaround procedures, and other planned process modifications or changes? Should all such procedures be in writing?
(f) Should compressed air be
permitted to be used as a purge gas for flammable or combustible material
containers and piping? Under what conditions? If compressed air is
permitted for purging flammable and combustible material containers and piping, what is the potential for a
flammable vapor-air mixture occurring? (g) Should OSHA develop standards
for high pressure steam or water equipment used in the cleaning of
equipment? (hj Should OSHA propose
requirements for the use of system safety analysis, such as failure mode and effects analysis, for new operations, shutdowns, and turnarounds involving hazardous materials? Such analysis would be conducted before any new operation, shutdown, or turnaround
occurred and would include a study of conditions and environments that effect system failures, the modes in which failure could take place, the problems that could be generated, and the
preventive or safety measures to be taken.
(i) Should OSHA require employers to prepare and implement a system safety
program which identifies all hazards capable of causing a disabling injury or death in each operation and defines the
alternative measures to eliminate or
control those hazards? {}) Shoud a system safety program
include all of the following: failure mode
and effect analysis: fault tree analysis: sneak circuit analysis including risk
assessment and hazard control?
(h) Should the scope of the system safety plan include: (1) design of new systems/facilities: (2) modifications to existing system/facilities; and, (3) operations and maintenance of systems/ facilities?
Public Participation
Written Comments and Information
The written comments and information requested in this notice must be submitted on or before July 30, 1981, in quadruplicate to the Docket Officer. Docket S-013. Room S6212. U.S. Department of Labor. Occupational Safety and Health Administration. 200 Constitution Avenue. N.W., Washington. D.C. 20210.
Public Meeting
In order to provide an informal fon.m in which interested persons can orally present comments and information regarding the issues discussed in this notice or on any other aspect concerning the regulation of hazardous materials in Subpart H. OSHA has scheduled a public meeting for April 8 and 9.1981. in the Auditorium, Frances Perkins Department of Labor Building. 200 Constitution Avenue. N.W., Washington. D.C. 20210.
The meeting on each day will begin promptly at 9:00 a.m., will recess from 12 noon until 1:30 p.m. and then continue until 5:00 p.m. 'Hie chairperson will be a representative of the U.S. Department of Labor, designated by the Assistant Secretary, and will have the necessary authority to regulate the conduct of the meetings.
OSHA requests that any person wishing to make oral presentations submit a notice of intention to appear by March 13.1981. Notice should be addressed to Mr. Tom Hall. Division of Consumer Affairs. Room N3635, U.S. Department of Labor. Occupational Safety and Health Administration. 200 Constitution Avenue, N.W., Washington, D.C. 2C210. The notice should identify the person and/or organization intending to testify, the amount of time requested for oral presentation, the subject, and a brief summary of the intended oral presentation. All persons giving writtern advance notice will have time reserved for oral presentations. Persons who do not submit advance notice, but who still wish to testify, are requested to register at the meeting they attend.
As long as time permits, at] persons who wish to be heard will be allowed to make oral presentations. Howevr. priority will be given to those who register in advance.
CCR 000000212
Federal Register ! Vol. 46. No. 15 / Friday, January 23,1981 / Proposed Rules
Additional Public Meetings
OSHA w'uld like to determine if Iding additional public meetings in cations other than Washington, O.C. will enable more person to participate. Specifically, OSHA wants to know whether there are significant numbers of persons who cannot attend the April public meetings in Washington. D.C., but who would be able to participate in a public meeting held on a different date in a more convenient location. Such persons should request the Agency to hold additional meetings and indicate when such meetings should be held and die city or region of the country in which to hold the meetings. (Such requests should be sent to the address provided above for written comments.) OSHA will carefully consider such request in determining whether and where to hold additional meetings. Notice of any additional meetings will be published in the Federal Register. All written and oral submissions, as well as other information gathered by the Agency, will be considerd by OSHA in the development of proposed standards or revisions to Subpart H. In addition, these submissions will be available for inspection and copying during normal business hours at the OSHA Docket Office.
hority
This document was prepared under the direction of Eula Bingham. Assistant secretary of Labor for Occupational Safety and Health. U.S. Department of Labor. 200 Constitution Avenue, N.W., Washington. D.C. 20210.
Sec. A. 84 StaL 1503 (29 U.S.C. 655); 29 CFR 'art 1911; Secretary of Labor's Order No. B-- 76 (41 FR 25059])
Signed at Washington. D.C. this 19th day if January, 1081. Uda Bingham,
Assistant Secretary ofLabor.