Document DvGkbxjoqNL7B23Qj6OzEJMdo
Granite cutting, finishing Pneumatic hand tools Surfacing machine
Grinders Polishers, buffers, eta. Portable
Swing frame
Type of Hood
Local hood Local hood
VmUlftUoa
Air Ptow
Uroa) Transport
Velocity
(fpm)
Remark* and Reference*
500 cfm
500 cfm for tools np to 2% in diameter
1000 cfm for 2% to 2% in diameter
5.500-0,000 5.500-6,000
Ref. 26, 27 Typical hood 3 x 8 In
with 3 in fiange Hood surrounds tool
opening
Standard wheel hood Downdraft bench
Booth Booth
(See Table 45-1) Bench type, 2-400 cfm per sq,
ft of exhaust grille but not less than 150 cfm per sq ft of plan working area
100 fpm at face 100-200 fpm Indraft through
opening In booth face
SS i
Bef 22, 28 Ref 15, 19, 22, 29
Recommended for larger parts (Usual cfm per grinder
2,000-4,000)
Kitchen range
Canopy
100 fpm at hood face
1,500-1,800 Provide drip gutter on all mtenor vertical waffs to catch condensed grease Ref 30
Laboratory hood (provide Booth type with door)
50-100 fpm
Ref 24, 31. Air supply location very critical
Metalixmg
Local hood Booth
200 fpm at hood face 125-200 fpm at booth face
3,500 3,000
Ref. 15 Not recommended for
toxic materials Use higher ventilation rates for
toxic materials
MUexs
Enclosure
Motion picture protector Enclosure (carbon arc)
100-200 fpm through feed and in 3,000-3,500 Ref 19,22 spection openings
12-100 cfm (for fume and gas re moval) directly exhausted from projector housing
Ref. 31. 1,000-1,500 cfm or 20-30 air changes per hour for heat removal
SAFETY ENGINEERING TABLES
>
2 |*j
*-<
tq
%
o 5
-
O ^
^
f*
t*j
State or Local Regulation! Should Be Consulted and Followed Where Higher Ventilation Rater Are Specified