Document Dv64NKbnb7EpX7Y8dwz695KXa
November 6, 1973
PLAINTIFF'S EXHIBIT DOW-641
R. C. Goheen Styrene Plastics Maintenance 759 Building
cc: N. S. Kigar, Styrene Plastics Maintenance, 759 Building
PERSONAL MONITORING RESULTS FOR ASBESTOS
The results of the personal monitor worn by Ray Bowers while bagging and stripping a reactor in 658 Building are as follows:
Master Number
27886
Operation
Bagging and stripping asbestos insulation in 658 Building*
Date 10/23/78
IHG Wearing respirator during operation
Time (min.) 24.8
Asbestos fibers/cc
0.65
2.0
The results above indicate that no overexposure would have occurred even without the use of respirator protection. The good use of controls such as water, roping off the area, disposing in plastic bags and posting of warning signs should be commended. The only additional suggestion would be the use of rubber boots during asbestos demolition projects.
S. L. S. Dombrowski Industrial Hygiene Laboratory Health and Environmental Research 1803 Building 636-2939
jdb
ST000I 687
407360
yy<7 t /--/-- r. -t2Z4X
December 11, 1978
J. J. Mikusko ICPD Maintenance 209 Building
__
cc: W. Whelton, IC/SP Maintenance, 800 Building
THE RESULTS OF THE PERSONAL SAMPLES TAKEN FOR ASBESTOS ON DECEMBER 4, 1978, IN 107 BUILDING
Man Bill Hoffman pipecoverer
Ed Kusmierz - multi craft .
8-hour TWA permissable exposure
Time 315
315
Volumn (1) 559
578
F/cc 0.08
0.19
2.0
The results were without regard to respiratory protection.
If you have any questions contact me.
R A-OJLuta
R. A. Olson H&ER Industrial Hygiene Laboratory 1803 Building 517-636-0221
If
ST0001688
407361
CRI NUMBER
R&D REPORT
DOW CHEMICAL U.S.A.
RESTRICTED: for use within The Dow Chemical Company only.
DE p ARTMENT
HES USA Industrial Hygiene Laboratory
TITLE
omem-
LAoCrtA.uWiK
HEH2.1-1-38(16)
CATS ISSUED
January 11, 1979
ACCOUNT NO. PROBLEM NUMBER
367 9085000
'
INDUSTRIAL HYGIENE SURVEY FOR ASBESTOS FIBERS, POWER MAINTENANCE, SOUTH POWER, 500 BUILDING, MICHIGAN DIVISION, AUGUST 9, 1978
F. L. Sabel
REVIEWER'S SIGNATURE
R. W. Bohl
DESCRIPTIVE SUMMARY WITH CONCLUSIONS:
-d-i&J? /-/S.-T?_________________________________
(Include in this spoce references to data books, and to earlier related reports, patents and publications*)
An industrial hygiene survey was conducted at South Power,
500 Building, to evaluate employee's exposures to asbestos fibers during the application of asbestos insulating blankets to a large steam operated turbine generator. A personnel breathing zone sample of the "B" maintenance man was col lected with a battery operated pump with a calibrated air flowrate of 1.0 Lpm when connected to an inline 47 mm filter holder containing a 0.8 micron Type AA Millipore filter. An area sample was collected on top of the generator employing the above collection system at 20 Lpm. Asbestos fibers on the filter greater than 5 microns in length were counted using phase contrast microscopy according to the method of Bayer and Zumwalde, US. Public Health Service.
RIB UTICIN:
DOW C
D. Woodcock, Powerhouse J. Yount, Pow erhouse, 500 Building R. A. Gaska, Basic Ope'rations, 256 Building R. D. Olson, Incustria 1 Hygiene Services, 607 Building D. G. Egnatz, Medical, 607 Building D. J. Roberts , USA RD , 2020 Building D. Laviolette , Safety, 256 Building Industrial Hygiene Contacts Central Report Index, 566 Building
407362
0001689
^ C P C --JC34 L
STOOoI69o
The following concentrations of asbestos fibers were found
Sample Location
Sample Time (minutes)
Breathing zone, maintenance clas sification
177
On top of generator
170
Dow IHG
Sample Air Volume (L)
72
33
Asbestos Fibers/cc
0.10
0.003
2.0
The above results are within the Dow Industrial Hygiene Guide (IHG) of 2.0 fibers/cc of air and employee exposures to asbestos during the application 'of the asbestos blankets were judged acceptable.