Document De4G7O869o3QKJQYMjZ5V7Xn

YOUR "ASKAREL" TRANSFORMER SHOULD BE TOWOLDMONOQ30411 FAR A8 EQUIPMENT CAN BE I) test friend! Since "askarel" type transformers were first made in 1930, few pieces of electrical equipment have equalled these "juice controllers" in trouble-free service. The name "askarel" applies to the liquid insulation that fills askarel type transformers. And "askarel" is a general name for a unique kind of chemical classified as a halogenated hydrocarbon. But., don't let this chemical jargon bother you one bit. After you read this little pamphlet, you'll be an EXPERT on operating askarel transformers; you'll know all about this wonder ful liquid askarel insulation because it's all very simple. Since many engineers and maintenance operators work with BOTH askarel and transformer "oils," you will want to remember that askarel is different from mineral oil . . . and you'll want to know the simple ways to "check up" on the health of your askarel transformer. That's the reason for this pamphlet. First, to tell you that your askarel transformer, in addition to being F1RESAFE, can be the most trouble-free piece of equipment you operate. Second, to give you the few simple facts that will make you an expert on the "whys" and "wherefores" of the easy maintenance. Knowing the facts given on the following pages, you will keep your askarel (and transformer) operating at trouble-free, top performance, year, after year, after year.* 'We own one that has been operating as faithfully as a hasrt beat for 28 yearsi Monsanto also supplies: Pydraul AC All synthetic fire-resistant compressor lubricant. Pydraul All synthetic fire-resistant hydraulic fluids. Thermal Fluid Fire resistant, non-vaporizing heat transfer fluid. Coolanol Dielectric coolants for high power electronic circuits. Fluid OS-59 Dielectric for high frequency power transformers. Askarel transformer fluids can be ordered directly from any one of these Monsanto sales service centers Atlanta Boston Syracuse W11 rn i r t o n TOWOLDMONOQ30412 LET'S OILS -- that can burn There are unite a number of these. They are sold by oil companies; and these mineral oils are used m transformers when1, if they catch lire, no great harm (besides the transformer itselfi comes from the burning oil. If water gets into an oil-filled transformer, it. lends to settle through the oil to the bottom. There are certain ways to check on the health of mineral oil insulation, loo, but the Check points" are somewhat different than for askarel. ASKARELS -- that cannot burn Although there are TWO /;// of askarel fluids <supplied under a number of brand namesi, actually they all have just, one and the mime basic ingredient: Monsanto's Aroe!orK 12(>U. (If you want to know, Aroclor 12(>0 is hexachlorobiphcny!i. And THIS is one of the world's best liquid insulations! don't worry about "different kinds" So, what are the two types? What's the difference? Simply this: they have different pour points and the liny amount of "scavenger" chemical added to each is different. The I'yranol 1170 (General Electric: type has the lower pour point; it will still pour at -IT0 below 1F.1 zero. The Inerteen ITU i Westinghoiise .- type will pour down to 26 below F.. zero. These two types each contain a liny amount of a different additive; both additives are good and do their job. However, the additive in Pyranol type askarel can crystallize out a bit at IT above iF.i zero. It does no harm; tiecrystals disappear after a while when the transformer warms up. Uther brand names, like fblon-xlol Allis Chalmers-; Notlamol 'Wagner Electric ; Ashestol Amert ran Corp. ; Sal'-T-Kuhl kuhl- man Electric- are either one type or the oilier. Some manu facturers simply call their fluid by the common descriptive name- askarel. But, transformer manufacturers who supply askarel thuds have sound reasons lor favoring their own type. So, it's best in stay with your particular brand. However, since basically askarel is askarel, there will be no difference in the operation of your transformer if IN EMERGENCY you would Interchange or even mix the two types! But askarel is NOT oil cannot, should not, must noi lie mixed with ordinary transformer oil. For one reason: the mside core materials used with mineral oil tilled units get gooey with askarel. For another reason over 2` , of mineral oil mixed into askarel 'clobbers" its lire resistance. For another reason never mind' Don't nii.r or nih'rchaiiip' uxkn'i-l and ml. "Askarel" liquid insulation is a vers carefully-manufactured, highlv pure, chemically made fluid. It does not vary in composition like the range of oils. AND . . . askarel is hrunrr than water. If water gets into askarel insulation, only a smidgeon 112.7 ppm dissolves the rest thxih mi top. Axkaril /x one <>; the nmxt iirr-n'xixtaitt, rhrnnrnlli/-nirrt, hi ut-xtuhhliijuiilx eirr ilvrelapai! You can lie sure of this: askarel does not deteriorate when exposed to air. heat, hot metal; it does not break down over long use to form conducting or corrosive chemicals; it does not sludge or oxidize. Askarel will remain perfectly stable year after year after year unless broken down by exposure to severe arcing the kind that could set an oil transformer afire. The only real "enemy" of askarel is: contamination by water. 03W900 TOWOLDMON0030413 NOW LET'S TALK year to year operation! One of the most brain-y electrical engineers in the business once said: "The best 'maintenance' for askarel transformers is KEEP 'EM DRY. and leave them alone!" This business of "keep 'em dry," however, whether your trans former is EITHER an oil-type or an a,skarel type, is the watchword! Il lakes some care. In fact, anything MECHANICALLY you can do to stop moist air breathing and condensation will be the best health insurance for your liquid filled transformer. Here are some of the questions that come up when you want to "keep 'em dry." Is your transformer a welded shell or a gasket top? (even the tightest gaskets can "breathe!") Does your transformer run, stop; run, stop; run, stop? (This hot-to-cold temperature cycling makes the breathing taster and harder!) Is air around it mostly cold and dry or hot and moist? (Wouldn't it be great for automobiles and transformers if there wasn't any such thing as condensation!) When you have "breathing" and high humidity you can cut back on check-ups if you fit the transformer with a drying device iall transformer makers offer these) or you can bleed dry nitrogen into the shell. Any mechanical steps you take to stop inside con densation will be double insurance on trouble-free operation. Of course, if you are ordering a brand new transformer either oil or askarel type you can "design out" most of the moistureentry points. Musically, you call for all-welded construction, in cluding fins, pipes, and instrument connections AND a recessed gasket for the hand holes. (If you or your electrical equipment supplier would like more complete details on tips to keep innards dry, we can send you a copy of; "Design Details For Moisture Protection of Liquid In sulation Transformers.") So you'll be happy to learn that preventing moisture contamina tion is the only major health insurance you need provide for your askarel insulation. CHECKING THE CHECKPOINTS Now you are well on your way to being an "expert." Since you know that keeping tabs on MOISTURE is the major checkpoint on your askarel transformer, let's ask: How do you keep tabs on moisture? You do this by a periodic test of the askarel's dielectric strength- Do not bother to check -- or if you do -- do not bo misled or dis turbed by relatively high power factor... or evon a drop in volume resistivity. (If you want to know why. you can read the fine print on the following page.) The DIELECTRIC STRENGTH of the askarel is your major clue to the "health" (i.e. dryness) of your askarel transformer. Besides taking a good look at a sample of your askarel -- dielectric strength is the only "test" you need actually run! Here's why: the dielectric strength of askarel is sensitive to moisture; nol sensitive to other ordinary contaminants (like metal dust, salts, dirt, etc.). The dielectric strength is also hurt by severe arcing, but you'll know that arcing is the culprit if the askarel has gotten noticeably black or has particles of sooty carbon floating in it. Unless you've had severe arcing (lightning, accidental overload, back surge, etc.), the dielectric strength is your "moisture indicator." New askarel has a minimum dielectric strength of 35 KV at 25C.; a maximum moisture content of 30 ppm. If you check the dielectric strength periodically, find that it is rapidly decreasing this is your "clue" to moisture pick-up, arcing, or both. When the moisture content rises to 100-120 ppm (or over) -- the dielectric strength will drop to 20 KV or less. That's your clue! INSPECT FOR WATER CONDENSATION IN THE SHELL. AND "REFINE" THE ASKAREL. As the operator, you will have to judge how often you want to check up on your askarel insulation. Steadily running, well-sealed askarel transformers have run as long as 25 years on the initial charge of askarel -- and the dielectric strength still checked out at above 30 KV. HOWEVER, if the dielectric strength drifts down ward to 25-20 KV at 25C. -- then it is time to "clean-up" the liquid insulation and to get rid of any water accumulation in the shell, too. This askarel clean up is relatively simple; the askarel need NOT be discarded. BUT MOST IMPORTANT ... if the dielectric strength drops rapidly over a short period of time, this shows rapid pick-up of water (or arcing). When you take your sample for check-up -- be sure to take it carefully (so it represents the surface) and handle the sample properly (so it doesn't pick up moisture in the sampling). 01 il'"1 TOWOLDMON0030414 How to check test your a You'll be able to "take the pulse" of your askarel insulation with the following five simple rapid tests, i Three are simply `'inspcci nmbv-eye!"i You can do these check-ups yourself or have the tests run by a local transformer service shop. 1 COLOR 'by inspection i New askarel is a clear, faint - yellow liquid. After long-term use, the color will gradually intensify to brown. Any color change, such as taking on a green, red or blue cast, indicates extraction. If sou find a distinct rhamjr in rotor, the complete range of electrical characteristics should be checked to learn if the extracted color is the tell-tale for contamination. CLARITY i by inspection > New askarel is clear and should remain clear in service. Development of turbiditv or cloudi 2 ness indicates contamination from water, insulation par ticles, metallic dust or dirt. Cloudiness or turbidity calls for a complete analysis. The exception to this would be cloudiness in a cold sample of I')'HAS'OI. I This type askarel contains a scasenger additive which will '`come out" of solution when cold around la TV and cause white turbidity and perhaps show salt-like deposits on the trans former shell. If this is noticed, heat the askarel sample to 150-200F. for several hours and agitate. Cpon heating, the I'yranol's additive will redissolve, as it will in a warm transformer. BLACK COLOR AND SMALL CARBON PARTICLES hy in spection ) If the color of the sample is lilack. and especially 3 if suspended carbon particles can be seen, this shows that the askarel has arced and should be discarded. You can also detect exposure to strong arcing rhnniralhi, with indicator paper. Simply dip a piece of moist blue litmus paper into the askarel. If the blue litmus turns red, there is excess acidity from arcing beyond the limit absorbed by the "scavenger" additive. 0J5 7902 TOWOLDMONOQ30415 W insulation! DIELECTRIC STRENGTH ihy A STM 1)901. n77> Tlw l idl'd r ic siren gl h is i In* m>st i m port an t; and il is a si in pie 4 lest In make. The dielcctrie strength of new askarel is :ir> K V at T'>miiiimnni. This \ alue should not be allowed to tail below 35-30 KY. Contaminants iwhich may have pronounced elled on the power factor and volume resis tivity; nuitttllji iIn mit Itiwcr usA'rur/'s liicUctric slrcmjth. Reduced dielectric streamh almost always shows exposure to strong airing or moisture contamination. MOISTURE The moisture content of new askarel is d() parts per million maximum. The moisture sut unit nut level is about Ilia ppm at ordinary temperatures. When the moisture content approaches 1'Ja ppm maturation level;, the dielectric strength goes down. The moisture content ot askarel should not be allowed to rise over 70 ppm; it should be held as near as possible to dll ppm, NOTE: ll ymr sample shows dn-da KY dielectric strength, pm need not cheek tor moisture. However, il you do cheek moisture, use the Karl Fisher Method, AS I'M I >-l add. IF ANY OF THESE FIVE CHECK-UPS APPEAR ABNORMAL, CON TACT YOUR TRANSFORMER MANUFACTURER FOR COMPLETE ANALYSIS. These simple tests will sliow you tin- condition of your askarel insulation, but only nnlmrllii the condition ot your transformer. They can be relied upon alien the sample is carefully taken so as not to "miss" water globules Moating on the surface or adhering to t he shell m i he air space over the insukit ion So, if you have taken mechanical precautions against moisture entry into your askarel transformers and can "Keep 'em dry!" these tests will he your assurance ihni, between checks, you can "Forget 'em." *1 in* Ami'iic ,ui Institute ot l.lec ttical t iif'ineers (ms published a comprehensive anil informative Kuide titled "Proposed Guide lor Maintenance ol Transformer Askarel." Ait I. No /(>, December IUbH This guide describes properties to be inspei ted and i he AST M method to be used. Monsanto (omplelely analyzes each production lot ol transformer askarel by these methods prior to shipment However these official tests are NOT ES SENTIAL to I tie u er of askarel transformers. When a complete analysis is re quired in .) spec nil i ase. the user should request it from the transformer maker, who in turn can i all ori Monsanto if needed GROOMING ASKAREL FOR RE-USE If strong arcing has blackened askarel, throw it away; it costs less to replace arced insulation than to reclaim it. If there's been no arcing, but a low dielectric test shows moisture contamination, you'll find it is quite easy to refine the askarel back to good operating dielectric strength. Simply run the insulation through a dry, ab sorbent filter. Most operators prefer a portable refining apparatus, such as a plate press, fitted with a dolly, (available from Sparkler, Mundelein, Illj; or the earthen cartridge filter type, (available from Industrial Filter Corp., Lebanon, Ind.i. Filter paper liners for the plate press are available from Carl Schleicher & Schuell Co., Keane, N.H. Any flexible hoses and gaskets on the refining equipment should be lined with or made of materials that will not be softened by contact with askarel fluid. (Silicone or Teflon materials are suitable). If you use a filter press, before refining it is advisable to oven dry the filter paper at 1(K)C. for a half hour to remove all moisture. If the askarel to be refined contains excessive moisture, circulate it hot (55-60C.) through the filter fitted with the paper liners only first. Then, refit press with dry paper and load it with the absorbent earth. The earth refining process is simple: 1. SPREAD DRY EARTH EVENLY OVER THE FILTER SURFACE. Fine-mesh Attapulgus clay or Fullers earth, dried and activated by heating for 12 hours at 25CRC. immediately prior to use. is highly efficient. The amount of earth used should be 0.1 to 0.2 per cent by weight of the askarel (askarel weighs about 13 pounds per gallon). To deposit the earth evenly, stir one-third of the earth with a small portion of askarel m a clean container. Pump the mixture through the filter and follow with two more one-third portions. 2. PUMP THE HEATED ASKAREL FROM TRANSFORMER THROUGH FILTER. Circulate askarel taken from near the top of the transformer, pass it hot (55-60' C.) through the filter and feed back through the bottom transformer outlet. 3. CONTINUE CIRCULATING THROUGH THE FILTER UNTIL ASKAREL IS CLEAR. When the askarel is clear use the simple tests described earlier to check for restored dielectric strength. 4. CHECK THE TRANSFORMER AFTER REFINING. After refining the askarel, the overall power factor and insulation resistance should closely approximate the values it would show with new askarel fluid. If the overall power factor is more than 30-35 per cent tat 30C. and 60 cycles) it is considered POOR and it is advisable to run a complete analysis of the entire insulation system. 03W903 TOWOLDMONOQ30416 POWER FACTOR & VOLUME RESISTIVITY High power factor and low volume resistivity in transformer mineral oils arc commonly regarded as "danger signals" that the oil has deteriorated and broken down chemically. This is NOT true of nskarel liquid insulation. New, (limned nskarel shows these electrical values: Power Factor; O.Ofi-ft.21'; t" 60 cycles 20"C. (about 1.2.0''; <" (it) cycles 10()O.i Volume Resistivity: 100-1000 x 10ohm-em (<< 10l)(\, 500V., DC., o.l" gap) 1'scd asltarel from SATISFACTORILY OPKRAT1NT, TRANSFoRMKRS normally 'ami frequently i shows Lower Factor: 20 to 80',' r 60 cycles 100C. \'olume Resistivity: about 2f> \ Id11 ohm-ent t(" 10t)C., 500 \',, DC., o.l" gap 1 This relatively hiyli power factor and relatively low volume re sistivity of used askarel ARK TO UK KXPKCTKI). Kven at these levels, the askarel's dieleetrie strength is STILL in the 80-05 KV range. The reason is simple: askarel, unlike "oil," is a relatively polar liquid. The volume resistivity is sensitive to traces of conductive nmtaminant.H. However, even in the presence of large amounts of contaminants, the volume resistivity does not seem to fall below 10 x I (I" iofmi-cmi. Vet tile dielectric strength remains high, be cause intrinsically askarel remains a non-conductor. To quote from Insulation Maga/.me, December 10(11 D1KLKCTR1C LOSS YARDSTICKS by John O. Holts, Manager Insulation Development Section, and Oraliam Lee Moses, Manager Services Kngmeermg, Westinghouse Kleetrie Corp., Kast Pittsburgh, Pa. "Dielectric loss is a good comparative evaluation for some characteristics of insulation. It may he used for comparing similar samples of the same materials. It may not be used as an overall evaluation for com paring different, materials." <i.e. "oils" and askarels' Power factor is not an important criteria of askarel insulation eflieieucy IN A PUOPKRLY CONSTRUCTED TRANSFORMKR. However if improper construction materials or unpredictable foreign conlnmmunts enter the system high power factor nn the absence of moisture in the shell i can indicate improper construction. NOW . . . since you know that the DIELECTRIC STKKNCiTH is the most important checkpoint, and that iexcept for arcing' MOISTURE is the villain that saps dielectric strength you want to make sure that your SAMPLE truly represents vmir askarel insulation. TAKE YOUR SAMPLE AS CLOSE TO THE TOP OF THE LIQUID SURFACE AS POSSIBLE! (Many large askarel transformers hast- a huilt-m sampling tube near the surface for convenient sam pling. If additional sampling tube connections are contrived on to valves for easier sampling, make the tubes of clean glass, stainless steel, aluminum or t in for rigid types: and silicone or Telion tubing for llexible types.) Water//oofs on askarel. If there is any water in tour transformer, it may collect m little puddles ON TOP of the askarel. A\'l>, therefore, more water will probably be dissolved in the n-karel near the top, where it. contacts any collected condensation. If you find low dielectric strength and high moisture m the askarel, you will probably want to thoroughly dry out the shell and lake some mechanical steps to keep it dry. When you take your askarel sample for testing, take the -..inm precautions ibu! no more' ihal you take when sampling mineral oil. 1. Select a dry day. Do not sample insulation on a warm, moist day when humidity exceeds 75%, and 2. Make sure that the askarel is at least as warm as ttie sur rounding air. (Cold liquids can condense moisture from humid air ) 3. NEW containers tor fluid sample Vour sample container should be a new and previously unused small mouth pint glass bottle fitted with a Bakebte screw cap fitted with an aluminum or tin bottle cap liner Make sure that the new bottle does not stand around open to collect dust or moisture. Rinse the sample bottle and cap lining two or three times with askarel from the transformer then fill it. When sample will be tested promptly, a clear glass bottle can be used. If sample is to be stored indefin itely, use an amber glass bottle or wrap clear glass with aluminum foil. Whenever a sample is to be shipped to the transformer manufacturer (or to Monsanto) for complete analysis, the container must be a 5-pint amber glass bottle, lor your convenience, various transformer man ufacturers and Monsanto will send you the sample bottle filled with new askarel. You simply empty out the new askarel and re fill bottle with your sample. 0 JW'iO*. TOWOLDMONOQ30417 THAT'S THE STORY: ** keep 'em dry... let 'em alone! Hut you might want these storage and handling "tips" to make you a complete transformer askarel expert. STORE NEW ASKAREL IN A CLEAN DRY PLACE Keep the 5, 30, or 55 gallon drums dry; turn them over on their sides to keep water off the drum head, ill can he sucked in by the drum "breathing."; CLEAN UP SPILLAGE Askarel can. if left standing, attack paint, rubber, or plastics. Absorb it from floors with sawdust, sweep, and then wipe dry. Use a rag wet with mineral spirits if you want to make sure it's all cleaned away. TAKE ORDINARY PERSONAL CARE Transformer askarel has been made, handled ami used lor over do years without causing toxic or other ill effects. Askarel can be handled in the same manner as insulating mineral ml. As with mineral oil, there may be some people allergic to askarel, so pro longed skin contact should be avoided where possible. When accidentally spilled or splashed on the skin, askarel does not present an acute hazard nor will it cause serious skin irritation. Simply wash it off with soap and water. If work clothes become impregnated with askarel, they should be removed and washed. Eye contact may cause temporarily painful irritation but \() PERMANENT DAMAGE to the tissues or sight. Flush the eye with large amounts of water. A drop of castor oil may be put in the eye. As with all eye first-aid, refer to a physician who will treat the eye with an ointment. Ordinary, infrequent exposure to askarel vapors will not cause any ill effects. However, prolonged exposure to strong vapors should lie avoided. If hot fluid is to be handled in a closed or confined area, provide ordinary exhaust ventilation. Harmful concentrations of askarel vapors are easily detectable by the smarting of the nose or eyes. Should hot askarel (above 100C.) have to be handled in the open in a confined, unventilated area it is advisable to wear organic canister-type masks as supplied by Mine Safety Co., Pittsburgh, Pa. 0357905 TOWOLDMONOQ30418