Inter Office
Mr. J. A. Hudson, Manager Dearborn Glass Plant
Personnel and Orpenliation St*u
December 8, 1981
cc R. Kuhn M. S. Lechner, M.D.
P. B. Paxton R. Smith
Subject: Industrial Hygiene Survey - Asbestos Analysis Reference: Glass Plant Storage Memo - November 18, 1981
Per the request of Mr. R. Smith, three bulk insulation samples from the Glass Plant storage area in the AAD warehouse were submitted to Clayton Environmental
Consultants. These samples were analysed for the presence of asbestos using the exhaustive technique of X-ray diffraction.
The results indicate the following:
Sample Description
Pipe insulation, east side, main ramp, Col L6
Pipe insulation Col J10
Pipe insulation Col B-19 Pound on floor
Asbestos Contamination (%)
1 -- 2% Chryeotile 6% Amosite
l8-20 Chryeotile No other forms detected
B% Chryeotile No other forntB detected
This material, used as insulation covering pipe, does not pose a significant inhalation hazard to employes working in the area unless there ie actual cutting or ripping of the material aB would typically occur during maintenance activities. As with any work performed on insulation containing asbestoB, proper precaution should be taken in accordance with OSHA regulation 29 CFR 1910.1001. These precautions include:
. Wearing impervious, disposable clothing . Wearing Corporate-approved respirators . Special changing and decontamination areas . Proper housekeeping and maintenance procedures such as wet methods and
vacuum cleaning . Visible caution signs and labels . Proper disposal methodB such as collecting waste materials in impermeable,
clearly labeled bags . Medical surveillanoe of employes exposed above 0.1 fiber/cc.
If there are further questions, please contact me on 33-78955*
[i/j. & Lt\
Alan R. Amberg, Industrial Hygienist Industrial Hygiene^a Toxicology Department Employe Health Services jb