Document DdnGZD0wx2Mw7NLX2eDEMqwxa
r'
C*
4/1/74
.Date
COSV! BTiaty!;.'-'' :v4'--
r ;l y
i'irra . !
A f \ 5 ,
v. -
association im c.
1623 EYE STREET, N .W ., W A S H IN G TO N , D .C . 20506 PHONE (202) 593-2070
To The Talc Subcommittee
From Norman F. Estrinl Ph.D.
Please:
Attend to
Note and return
I I Note and forward to
L~` Files
r n See (phone) me re '-- attached
I Prepare reply for my -- signature
I I Send me information 1-- 1 required to answer
f i t For your information
As per conversation
. As requested
I I For your comments '-- 1 and suggestions
I I Does attached meet 1-- 1 vvitfi your approval?
f I For signature, if you 1-- 1 approve
1 | Make----------------Photo Copies
Other Remarks
P LA IN T IFFS EXHIBIT
WCD-397
Goodhue WCD 000193
A M E R I C A N CYANAM'ID COMPANY.
C O N SU M ER P R O D U C TS DIVISION
P. O ,
BOX
151, C L I F T O N , A R E A C O D E 2 Cr 1
NEW J E R S E Y
544- 7000
071S
March S, 1974
Dr. Norman Estrin The Cosmetic, Toiletry and Fragrance Assoc., Inc.
1625 Eye Street, N.W. W a s h in g t o n , D.C. 20006
Dear Norman:
I ashed our microscopist at the Stamford Research Laboratories to comment on the "Final Report of CTFA Talc Subcommittee" and sent a copy to Dr. J. Longfellow who requested that I provide you with as many copies
as you deem useful. I, therefore, am enclosing eight (8) copies of the
report. If more are needed, please let me hnow.
F D B :dt
F. D. Barbuscio
Goodhue WCD 000194
I . t '
,'-.f;
r-':
STAMFORD RESEARCH LABORATORIES
RESEARCH SERVICE DEPARTMENT REPORT
to M r, I r a n i : B a r b u n c io
FRCM
M icro sco p y
material M e th o d : A s b e s t o s i n T a l c
charge NO, 2096-35 ( 546- 7145) WORK REPORTED 9Y D . W. D a v i
d e p t . C o n s u m e r P r o d u c t s ; f room no.
'
DATE REPORTED
2- 25-74 i
test
M ic ro s c o p ic a l E x a m in a tio n
DATE SUBMITTED 1- 11-74 i
-
NOTEBOOK REFERENCE S _ 1093l . P O . 110.111
:
Introduction
i-
'
\ Our comments on the data you have submitted concexming
the Dept; of Health, Education and Welfare's microscopical method
1
|
for determining the amount of asbestos'in talc mayibest be divided
into two parts; the test procedure itself and the Objections
raised;by-the CTPA subcommittee after a round-robin trial.
Test Procedure
.i
-1 1. Sampling,
|,
The method of campling should be specified. Micro-
riffling would probably be universally acceptable for powders
of allsizes and compositions;
i
!' 2, Size of Sample.
: j The test specifies a weight of one mg.; depending on
the .size-range of the talc product, this may be too much or too jii n
t'
i- .
little ito be truly representative,
'{ . ...
i 3* Criteria for a Piber.
.. . V .. ; Two of these criteria (li and iii) may become contra-
dictor. These criteria stipulate that fibers must have a length
o 5 micrometers or greater and a width of 5 micrometers or less.
Thus, e| fiber 50 micrometers long and 8 micrometers wide (perfect
ly possible) would be in conflict with itself! The aspect ratio and
the'length suffice to define the fiber dimensions; 'width should not
he specified.
i
i
4, Area to be Examined, i ;; i
!
. t.
' /' '] Assuming that one mg, is representative,; the maximum
area suggested for examination is 648 sq, nun. This seems unnsces-
aarily -Large for routine microscopy, for it involves approximately
100 traverses of 50 fields each at 4001, or approximately 5000 fields,1
If the sample is well-dispersed, as specified, 10 equally-spaced
traverses, involving about 500 fields, should be adequate. . >
ESD=i
,r
Goodhue WCD 000195
22096-35
General Comment
. :J;_,-vv ,... .
-'." j Our Microscopy Laboratory can perform.this test.
However, we feel that the time required would probably be
one tpctwo days per sample, if* the figures are to:be meaning
ful. '
.'
1 t ..
iObjections by the OHFA Subcommittee
<. '
''
!/; ^ O b j e c t i o n iio. 1.
1
i `-
. ; This objection seems invalid, since theitest re
quires that, both indices of refraction exhibited by a fiber
be below 1,574- if the fiber is identified as chrysotile.. .
Also, ;lt seems unlibely that an experienced mineralogist
would confuse fibrous talc,or edgewise, platy talc, with
chrysotile, as other optical characteristics, i.ej, detailed
morphology, interference color, change of relief on rotation,
etc., would usually be distinctive,
* /. .
.- Objections Ho. 2, 3, A, 5, 6 and 7,
,j
.
" ' These all appear to be valid, General CommaTTh
!'
]
; It is quite obvious, from the disparity Of results obtained in the round-robin trial, that the test, as presently designed, is not practical. Of the seven alternatives sug- gested, Ho, 1, (Modified Optical Method) still seems to offer the best chance of successful application by the industry.