APPENDIX I
Procedure
for
Measurement of Airborne Concentration
Respirable Particle
ARP
A 9 oz containeorf powder is placed in a mechanical device
shaken vertically at a fixed rate to deliver about 1 gram of
and
powder The shaker is located within a closed chamber so that any airborne dust is contained within the chamber and is rapidly dispersed and uniformized by means of a small circulating fan The airborne dust is sampled with a 10mm nylon cyclone at a
1.7 min flow sized particles
rate The cyclone separates out
and delivers them to a TS1 3210A
the respirable quartz crystal
mass monitor for weighing The concentration of respirable
particles as mg in the chamber is monitored and printed
out every 10 sec
'
@'
The the The
peak ARP concentration and the average ARP concentration for first two 2 minutes after shaking are measured and recorded peak concentration is normally reached in the first 10 sec
following shaking
i
The number of shakes and the powder delivered from the container
.
are also recorded as data