Document Dawkd9G42QMbdGQ098mw4Zna
UNITED STATES ENVIRONMENTAL PROTECTION AGENCY REGION 5
77 WEST JACKSON BOULEVARD CHICAGO, ILLINOIS 60604
SUBJECT: FROM: THRU: TO:
CLEAN AIR ACT INSPECTION REPORT Vantage Oleochemicals Inc., Chicago, IL
Karyn DeFranco, Physical Scientist AECAB (MN/OH)
Brian Dickens, Section Supervisor AECAB (MN/OH)
File
BASIC INFORMATION
Facility Name: Vantage Oleochemicals Inc.
Facility Location: 4650 S Racine Avenue, Chicago, IL
Date of Inspection: May 25th, 2022
EPA Inspector(s): 1. Karyn DeFranco, Physical Scientist 2. Brianna Fenzl, Environmental Engineer 3. Constantinos Loukeris, Environmental Engineer
Other Attendees: 1. Luke Toonen, Environmental Specialist, MWRD 2. Terry Sheahan, Environmental Engineer, Chicago Department of Public Health
Contact Email Address: Offsite Report
Purpose of Inspection: Conduct Clean Air Act offsite monitoring of air emissions from manhole covers along Vantage wastewater stream discharge.
Facility Type: Organic Chemical Manufacturing Facility
Regulations Central to Inspection: The FESOP permit and Illinois SIP including, but not limited to emission limits on the fatty acid plant. As well as the construction permit and 40 C.F.R. part 60 Subparts A, VVa, and NNN, including emission limits and monitoring requirements on the Luwa Glycerin Distillation (GD2) plant.
Facility Name: Vantage Oleochemicals Inc. Facility Location: 4650 S Racine Ave Date of Inspection: May 25, 2022
Arrival Time: 1:36pm Departure Time: est. 5:00pm
Inspection Type: Unannounced Inspection Announced Inspection
OFFSITE MONITORING OBSERVATIONS
Data Collected and Observations: Offsite monitoring was conducted on manhole air emissions along the wastewater stream flow out of the Facility. "Manhole D" is the outlet of Vantage Oleochemical's process wastewater discharge into the system near MWRD sampling point 1A. MWRD confirmed that only Vantage Oleochemical is discharging into the sewer at Manhole D. "Manhole A" is the location that EPA took a Summa canister grab sample from on April 26, 2022. Manhole A is downstream in the sewer flow from Manhole D.
EPA took total hydrocarbon readings with a 2020 TVA and Benzene concentration readings with a handheld Phocheck Tiger Select PID. The highest readings were observed from Manhole D. See Appendix B.
Photos and/or Videos: were taken during the inspection. FLIR videos were taken during this inspection. See Appendix A.
Field Measurements: were taken during this inspection. - Total hydrocarbon measurements were taken with a 2020 TVA. - Benzene concentrations were taken with a handheld Phocheck Tiger Select PID benzene gas detector. - Temperature was determined by the temperature spot on the FLIR camera.
DIGITAL SIGNATURES
KARYN
Digitally signed by KARYN DEFRANCO
Report Author: _D_E__F__R__A_N__C__O____-_0_5'_00_' ____________ Date: 2022.07.25 18:12:29
Section Supervisor:
Digitally signed by Frank,
Frank, Nathan Date: 2022.07.25 21:58:04 Nathan
__________________-0_5'_00_' _____________
Page 2 of 3
Facility Name: Vantage Oleochemicals Inc. Facility Location: 4650 S Racine Ave Date of Inspection: May 25, 2022 APPENDICES AND ATTACHMENTS 1. Appendix A: Digital Image Log 2. Appendix B: Field Measurement Data
Page 3 of 3
Facility Name: Vantage Oleochemicals Inc. Facility Location: 4650 S Racine Ave Date of Inspection: May 25, 2022
APPENDIX A: DIGITAL IMAGE LOG
1. Inspector Name: Constantinos Loukeris
2. Archival Record Location: C:\Users\kdefranc\OneDrive - Environmental Protection Agency (EPA)\Illinois\Vantage Oleochemicals\MONITORING\FLIR-05-25-22
Image Number 1
2
File Name MOV_0303 MOV_0304
Date and Time (incl. Time zone and DST) 05/25/2022
05/25/2022
Latitude and Longitude
41.812411, -87.65516
Description of Image
Plume from Manhole A, B, and C at the intersection of S Racine Ave and 45th Street Accidental save- video of nothing; lens cap on.
MOV_0306
05/25/2022
41.81154, -87.65524 Plume from Manhole D
3
Appendices Page 1 of 2
Facility Name: Vantage Oleochemicals Inc. Facility Location: 4650 S Racine Ave Date of Inspection: May 25, 2022
APPENDIX B: FIELD MEASUREMENT DATA
Manhole ID (designated by Inspectors)
A (slotted manhole) B C
D E
Lat.
Long.
41.812411
41.812398 41.812345
41.81154 41.81296
-87.65516
-87.65524 -87.65529
-87.65524 -87.5497
Benzene reading from Tiger Select PID (ppm)
3.3
Total hydrocarbon Temperature reading (TVA) (FLIR) (F) (ppm)
300
92-93
3.7
278
92-93
3.4
No measurement
taken
25.8
1508
2.5
No measurement
taken
Appendices Page 2 of 2