Sometimes a "must" ...but often
electrical engineers who know!
Askarel-type transformers have served industry, insti tutions, commercial housing, the military, electric utility companies and electric railroads safely, reliably, economically ... for over 30 years.* They are supplied -- built to exact specification --- by all major electri cal manufacturers. But only a relatively few engineers and electrical architects have dug into chemistry to learn WHY the askarel transformer is so fire safe, so reliable in operation, requires so little maintenance. Not too many electro-technologists know that askarel transformers (even when they cost a little more compared KV for KV with mineral oil transformers) can actually save money on the installation as a whole, and save money over years of use!
Askarel transformers are quite unique. And the "tradesecret" is the fluid. If you would like to join the "inner circle" of astute electrical architects and engineers who for the past 30 years have known just how, where, and why an askarel transformer should be installed . . . just check the facts (and factors) in the following few pages.
`Monsanto has manufactured and supplied askerel fluids since the askarel-type transformer was first introduced. Askarel type trans formers were first made by General Electric In 1930. The askarel fluid insulation was supplied under the trade mark Pyranol. Other electrical manufacturers soon developed askarel units using various trade marks for the askarel fluid, such as Inertoen (Westinghouse); Chlorextol (Allis-Chalmers); Nofiamol (Wagner Electric); Asbestol (Amertran Corp ); Saf-T-Kuhl (Kuhlman Electric). Many manufac turers, however, simply use the generic namo, askarel.
0221058
|
TOWOLDMON0025744 WATER_PCB-00010213
formers require pressure and their cost is high! But askarel transformers quietly handle their load, under surge and drop, delivering a steady power flow year after year. The secret of this quiet, fire safe service is the askarel fluid . . . the finest liquid insulation that chemistry has developed. Askarel fluid cannot be ignited by a blow torch! In ad dition, this dielectric liquid will not oxidize or sludge; will not attack or corrode metals; remains chemically stable when subjected indefinitely to temperatures at least as high as 150 C. The unique values of the askarel-type transformers all stem from the chemical, electrical, and physical proper ties of the askarel fluids.
0221059
TOWOLDMON0025745 WATER_PCB-00010214
FIRE SAFETY
Askarel fluids, unlike mineral oil, cannot be ignited . . . even by the heaviest arc, such as might accidentally be caused by lightning. Kqually important, askarel transformers cannot carry or add burning oil hazards to fires that may start from other causes. The fluid does not deteriorate when exposed to heat, hot metal, nor does it decompose over long use to ac cumulate electrically unstable contaminants. Since askarel fluid won't burn, and gases formed by arcing do not support combustion, the use of askarel transformers eliminates the possibility of fire and secondary explosion.
Fire a/e askarel transformers are the choice of far-sighted engineers for hospitals, hotels, schools, institutions, under ' ground networks, military bases, mines, shopping centers, electrical railroad systems, rocket sites.
OZ2V060
|
TOWOLDMON0025746 WATER_PCB-00010215
ECONOMY
Askarel type transformers cost about the same or very slightly more than open dry types, cost much less than sealed dry (gas) transformers. While askarel units cost up to 15% more than equal-capacity mineral oil units, this initial cost is only part of the economic picture: askarel transformers can usu ally be installed without the costly vaults, fire walls, or sprink ler systems required by safety codes for mineral oil units. Further savings accrue in the design of the power transmis sion system. Since askarel units can be placed in congested, closed areas without danger to workers, askarel units can be close to (he point of poucr usage. (See Performance Compari son Table) In addition, fire insurance rates are usually lower when askarel units are used.
DEPENDABILITY
A properly designed and installed askarel transformer will give trouble-free service for a minimum of 80 years. Since their introduction in 1930, the manufacturers report finding the overall failure rate to be less than 0.5% for all units under test and service conditions. The Edison Electric Insti tute's last report (1956-1958) on their member utilities pub lishes the failure rate for askarel transformers as 0.13 per hundred banks per year! Even these rare reported failures are found to be due to improper sealing that allowed moisture to enter. Modern design requirements for askarel transformer seals eliminates possible failure.
EASY MAINTENANCE
Askarel transformers are easiest to maintain! Most of the askarel transformers in service today have received little or no maintenance in decades of operation. Even the accumu lation of relatively large amounts of non-ionic contaminants has little effect upon askarel's excellent dielectric strength. The only contamination that seriously affects the askarel's dielectric strength is water. Proper sealing banishes this source Of contamination. Five simple periodic tests (three of them, visual) will check out the askarel insulation. Monsanto and the transformer manufacturers furnish guidance literature on this easy-to-follow maintenance. Unlike oil type trans formers, with askarel units there is no chance of fluid oxi dation or sludge formation, and therefore, less need for replacing the fluid.
LOW NOISE LEVEL
Askarel transformers operate quietly! Where open dry type transformers in office buildings, hospitals, schools and insti tutions require a sound suppressing room or locating far from point of use, askarel units are so quiet that no sound problem arises. Wherever a fire safe transformer is warranted, the askarel type unit operates at a significantly lower noise level than dry types and offers a significantly superior impulse rating over the dry type.
Askarel-Type Transformers Offer Five Important Advantages Over Other Type Transformers
Eliminate Fire Hazard More Economical to
Install and Operate
Proven Dependability Less Maintenance, Easier Upkeep More Quiet Operation
> F
C
< c
7
t D t C
*
c
u 3 t
0221061
TOWOLDMON0025747 WATER_PCB-00010216
BASE UNIT CO
200%
1
180%
160% 140%
Additional cost of
vaults, fire doors and walls, and/or sprinkler systems to meet safety and noise requirements can double original
unit cost.
120%
100%
(LOWEST BASE UNIT COST)
80%
TOWOLDMON0025748 WATER_PCB-00010217
1ST & ADDITIONAL EXPENSE COMPARISON
Utile additional installation cost BUT: original unit cost is higher than any other type.
little or no additional installation
cost; no additional measures needed
for fire and explosion safety.
(3-15% more t/ian mineral oil)
Little additional installation cost BUT: cannot be used where there Is excessive atmospheric dust, dirt, moisture, or where high noise level will cause
interference.
1 l i
T V c (
II
3
V
i l u 3
t
ASKAREL
4
OPEN DRY TYPE
SEALED, GAS DRY TYPE
TOWOLDMON0025749 WATER_PCB-00010218
Here are
foul
important
reasons
why engineers choose askarel
transformers!
SAFETY!
Freedom from fire and sec ondary explosion.
USE FLEXIBILITY!
Tightly sealed askarel trans formers can be used in at mospheres contaminated with dust, lint, corrosive vapors and moisture.
DEPENDABILITY!
Askarel fluid does not oxi dize or sludge.
LOW NOISE LEVEL!
Askarel transformers can be installed close to power sup ply outlets without causing objectionable noise.
FOUR IMPORTANT ADVANTAGES FOR INDOOR USE, AND FOR OUTDOOR INSTALLATIONS, TOO!
RANGE OF ASKAREL TRANSFORMERS
Askarel transformers are available in all capacities, in size ratings exceeding 15,000 KVA. Most askarel transformers in use to day fall in the 25 to 2,000 KVA range, the majority ranging between 100 and 1,000 KVA.
X
The following transformer comparison chart
/is devised to show the economics of askarel units in the 25 to 2,000 KVA range, which are used primarily for their superior safety features.
<^1064
TOWOLDMON0025750 WATER_PCB-00010219
compare the performance., advantages...
ASKAREL
OPEN DRY TYPE
MINERAL OIL TYPE
/CLOSED i 1 GAS
SEALED
Transmission NORMAL RANGE & Service Costs
HIGH
HIGH
HIGH
Supplemental NEGLIGIBLE
Installation Costs
HIGH (if noise damping or shield ing from atmos
phere, contamina tion & water is
needed)
HIGH (when used
indoors, requires vaults, fire walls, sprinklers and noise damping)
NEGLI GIBLE
Operational EXCELLENT Dependability
Affected by cor rosive atmosphere,
moisture, water flooding, dirt and
dust.
GOOD
EXCEL LENT
Amount of
Maintenance Required
LITTLE OR NONE
CONSIDERABLE
FAIR -- due lo oil s NONE tendency to degrade in service.
Operating Noise Level
VERY LOW
HIGH
MEDIUM
HIGH
impulse Levels
HIGH
LIMITED
HIGH
LIMITED
Safety from Fire
EXCELLENT AND COMPLETE
FAIR -- can cause ignition
POOR - can cause FAIR ignition and propagate fire
0^1065
TOWOLDMON0025751 WATER_PCB-00010220
HERE'S WHERE AN ASKAREL TRANSFORMER IS YOUR BEST CHOICE
INDUSTRIAL LOAD CENTERS In factory areas where maximum safe ty from fire is required and atmos phere contamination may prevail.
UTILITY NETWORKS Where location underground or above the surface requires protection from water and other elements, and where maximum safety against fire is needed.
INSTITUTIONS AND OFFICE BUILDINGS In schools, hospitals, government buildings, hotels, airports, shopping centers, sport stadiums, etc., where maximum safety and lowest noise levels are required.
WATER FRONTS AND BOAT DOCKS Where fire and weather resistance are the prime requirements.
ELECTRIC RAILROAD SYSTEMS Transformers on electric trains and throughout the system require maxi mum safety features and assurance against faulty operation due to weath er exposure.
MISSILE SITES Where surface and underground struc tures demand reliable performance and complete protection from weath er, fire and explosion.
CONGESTED OUTDOOR INSTALLATIONS Where safety from fire and explosion are required for crews working close to transformer units.
(J
TOWOLDMON0025752 WATER_PCB-00010221
-
Some engineers who have had no opportunity to acquire actual operating experience with askarel transformers and who have received little information about them sometimes harbor mis taken opinions that are contrary to the facts. Here are the three misconceptions that, however infrequent, have been occasionally encountered:
"Askarel fluids are `poisonous/ " The facts: askarel fluids have been manufactured, handled, and used for over 30 years without encountering toxic or ill-effects. It is well accepted by transformer makers and utilities that askarel fluids are not hazardous when handled under standards of normal good housekeeping and the ordinary personal precautions used with other inert industrial materials.
"Askarel transformers can explode." The facts: there is no instance, in the whole use history of askarel units, of sec ondary explosion (because gases formed by arcing are non explosive and non-combustible) 1 Even undeT strong arcing, the possibility of primary explosion in a properly designed and escape-vented askarel transformer is very remote. Modern design features, such as cable connection seals, completely protect askarel transformers from possible explosion.
"Askarel fluids run a high power factor." The facts: En gineers experienced with askarel transformers know that it is normal for an askarel transformer to show a higher power factor than a mineral oil unit.
It Is technically unsound to compare the Insulating efficiency of oil and askarel by simply measuring power factor. A high power factor in mineral oil i cause for alarm; HUT it is normal for askarel to show a power factor as high as 20 to 80 per cent at 100C, 60 cycles (2-8Vc at 20C) with absolute ly no danger of efliclency loss or impairing normal operation.
NOTE: The most significant and reliable measurement of transformer askarel is its DIELECTRIC STRENGTH. As karel will maintain its high dielectric strength unless there is significant moisture contamination or breakdown of the fluid from an unusually severe exposure to arc.
221067
|
TOWOLDMON0025753 WATER_PCB-00010222
Askarel fluids (both Inerteen and Pyranol type) are manufactured by Monsanto and shipped promptly to users anywhere in the world. Askarel transformer fluids, unlike naturally formed oils, are manufactured and quality-checked for consistency and shipped with an extreme care that is given to few industrial materials. This means askarel fluids can be depended upon to be uniform and provide the optimum service of any liquid insulation.
Operating with askarel units is the safest, easiest, often lowest cost way to distribute electrical power. Monsanto will be happy to send you a copy of the pamphlet "Care and Grooming of Askarel Transformer Fluid" or request a copy from the transformer manufacturer of your choice. And if you do . . . ASK HIM to check the facts on askarel transformers described on the pre ceding pages.