American Society of Heating and Ventilating Engineers Guide, 1937 boiler connection, and also in any case where the connection is less than y2 in. I.P.S. Each steam or vapor boiler should have at least one water gage glass and two or more gage cocks located within the range of the visible length of the glass. The water gage fittings or gage cocks may be direct connected to the boiler, if so located by the manufacturer, or may be mounted on a separate water column. No connections, except for combustion regu lators, drains or steam gages, should be placed on the pipes connecting the water column and the boiler. If the water column or gage glass is con nected to the boiler by pipe and fittings, a cross, tee or equivalent, in which a cleanout plug or a drain valve and piping may be attached, should be placed in the water connection at every right-angle turn to facilitate cleaning. The water line in steam boilers should be carried at the level specified by the boiler manufacturer. Safety valves should be capable of discharging all the steam that can be generated by the boiler without allowing the pressure to rise more than - 5 lb above the maximum allowable working pressure of the boiler. This should be borne in mind particularly in the case of boilers equipped with mechanical stokers or oil burners where the amount of grate area has little significance as to the steam generating capacity of the boiler. Where a return header is used on a cast-iron sectional boiler to distribute the returns to both rear tappings, it is advisable to provide full size plugged tees instead of elbows where the branch connections enter the return tappings. This facilitates cleaning sludge from the bottom of the boiler sections through the large plugged openings. An equivalent clean out plug should be provided in the case of a single return connection. Blow-off or drain connections should be made near the boiler and so arranged that the entire system may be drained of water by opening the drain cock. In the case of two or more boilers separate blow-off connec tions must be provided for each boiler on the boiler side of the stop valve on the main return connection. Water service connections must be provided for both steam and water boilers, for refilling and for the addition of make-up water to boilers. This connection is usually of galvanized steel pipe, and is made to the return main near the boiler or boilers. For further data on pipe connections for steam and hot water heating systems, see Chapters 32 and 33 and the A.S.M.E. Boiler Construction Code for Low Pressure Heating Boilers. Smoke Breeching and Chimney Connections. The breeching or smoke pipe from the boiler outlet to the chimney should be air-tight and as short and direct as possible, preference being given to long radius and 45-deg instead of 90-deg bends. The breeching entering a brick chimney should not project beyond the flue lining and where practicable it should be grouted up from the inside of the chimney. A thimble or sleeve grout usually is provided where the breeching enters a brick chimney. Where a battery of boilers is connected into a breeching each boiler should be provided with a tight damper. The breeching for a battery of boilers should not be reduced in size as it goes to the more remote boilers. Good connections made to a good chimney will usually result in a rapid response by the boilers to demands for heat. 458 Chapter 25--Boilers ERECTION. OPERATION. AND MAINTENANCE The directions of the boiler manufacturer always should be read before the assembly or installation of any boiler is started, even though the contractor may be familiar with the boiler. All joints requiring boiler putty or cement which cannot be reached after assembly is complete must be finished as the assembly progresses. The following precautions should be taken in all installations to prevent damage to the boiler: 1. There should be provided proper and convenient drainage connections for use if the boiler is not in operation during freezing weather. 2. Strains on the boiler due to movement of piping during expansion should be prevented by suitable anchoring of piping and by proper provision for pipe expansion and contraction. 3. Direct impingement of too intense local heat upon any part of the boiler surface, as with oil burners, should be avoided by protecting the surface with firebrick or other refractory material. 4. Condensation must flow back to the boiler as rapidly and uniformly as possible; Return connections should prevent the water from backing out of the boiler. 5. Automatic boiler feeders and low water cut-off devices which shut off the source of heat if the water in the boiler falls below a safe level are recommended for boilers mechanically fired. , , Boiler Troubles A complaint regarding boiler operation generally will be found to be due to one of the following: 1. The boiler fails to deliver enough heat. The cause of this condition may be: (o) poor draft; (5) poor fuel; (c) inferior attention or firing; (d) boiler too .small; (e) improper piping; (/) improper arrangement of sections; (g) heating surfaces covered with soot; and (ft) insufficient radiation installed. 2. The water line is unsteady. The cause of this condition may be: (a) grease and dirt in boiler; (6) water column connected to a very active section and, therefore, not showing actual water level in boiler; and (c) boiler operating at excessive output. 3. Water disappears from gage glass. This may be caused by: (a) priming due to grease and dirt in boiler; (b) too great pressure difference between supply and.return piping preventing return of condensation; (c) valve closed in return line; (d) connection of bottom of water column into a very active section or thin waterway; and (e) improper connections between boilers in battery permitting boiler with excess pressure to push returning condensation into boiler with lower pressure. 4. Water is carried over into steam main. This may be caused by: (a) grease and dirt in boiler; (b) insufficient steam dome or too small steam liberating area; (e) outlet con nections of too small area; (d) excessive rate of output; and (e) water level carried higher than specified. 5. Boiler is slow in response to operation of dampers. This may be due to: (a) poor draft due to air leaks into chimney or breeching; (6) inferior fuel; (c) inferior attention; (d) accumulation of clinker on grate; (e) boiler too small for the load. 6. Boiler requires too frequent cleaning of flues. This may be due to: (o) poor draft; (b) smoky combustion; (c) too low a rate of combustion; and (d) too much excess air in firebox causing chilling of gases. 7. Boiler smokes through fire door. This may be due to: (a) defective draft in chimney or incorrect setting of dampers; (6) air leaks into boiler or breeching; (c) gas outlet from firebox plugged with fuel; (d) dirty or clogged flues; and (e) improper reduction in breeching size. Cleaning Steam Boilers All boilers are provided with flue clean-out openings through which the 459 b