To : A. F. Gallagher From : C. G. Rooks Date ; October 31, 1974 Subject : VCM Monitoring - Area Samples
Additional sampling has been conducted in the same locations as reported in the letter of October 30. A summary of the data collected from 10/28 - 10/31 is presented below.
Sample Pt.
No. of 0-1 2-5 6-10 11-25 >25. %4l0 %*25
LocationSamples ppm ppm ppm ppm ppm ppm ppm
(1) Center of G 6 H Aisle in V-ll
360
245 62 25
19 9 92.2 97.5
(2) LR Control' 360 Room Storage Room
335 15
7
3 0 99.2 100.0
(3) Ambient Air to MED Trailer
360
326 28
1
2 3 98.7 99.2
(4) V-ll Charge 360 Panel
153 142 27
28 10 89.4 97.2
A further breakdown of data is given in the attached table.
C. G. Rooks Process Engineer
cw
cc: EMS, GWP, RWS, FMW, FJS