Document DMBN9XRdgXvZpZe6rNDyOJmpn

Monsanto '" wi Charlee E. Cutchena April 7, 1972 PCB Survey WIRIMt TO : D. S> Jennings confidential cc< D. W. Brubaker C. R. Campbell aD. E. Danly B. T. Dean l/C. J. Fountain J. E. Lipe ) J* N. Maloney C. E. Rannefeld J. J. Vick S. L. Waltera A. J. Zablaekl A survey of Che north ditch drainage make-up area reveals that a rather larga atctlon of plane proparty la contaminated with PCS. A nap locating eha aanpllng polnta around tho yarn plant la attachad. Tha analyaaa ara llatad In tha following tabla; Sample Date Type Location PCB aa Aroclor 1254 No. 1972 62 3/10 water River, acroaa fron old O.F. 63 3/14 water South outfall 64 3/3 water Roof of Yarn Plant 0.1 0.2 0.4 63 3/14 water North Ditch 0.7 66 3/6 aoll SW corner of 710 at substation 112 67 3/6 aoll S of Tarn Plant near 711 and plant fence 82 68 3/6 soil E of Yarn Plant and W of garage 69 3/6 soil NE corner of Yarn Plant at RR track 70 3/6 aoll NE corner of 601 and W of Texturlaer 82 78 N.D. *N.D. Datactlon Unit for aoll sanplaa waa 10 ppb. Tha watar aanpla fron tha roof of tha yarn plant waa taken at varloua polnta on the roof laeaedlately after a large rain, t.e. It waa not concen trated via evaporation. Tha PCB waa Aroclor 1248 which la In coneraat to the Aroclor 1254 found In all other aanplea Hated In thla report. Since the water aanple contained a relatively high level of Aroclor 1248, one would expect the roof-ear aanple to contain a rather high level. An attract waa nade to analyte a aanple of roof-tar for PCB. A clear PCB pattern could not be obtained becauaa of escaaalve Interference, but there were certain lndlcatlona that the aanple contained PCB. The beet eatlnate la 100 ppn calculated aa Aroclor 1234. The water aanplea fron the north ditch - on the average - contain approxlnately 0.7 nob Aroclor 1234. The retlo of PCB concentratlona (water/ mud) In the north ditch la much greater than In the old aouth outfall. Thla auggeata aourcea of PCB exlat other than the mud In the north ditch. The mud In the north ditch la an ordar-of-magnltude higher In PCB content relative to the aoll In the drainage nake-up area, but the larger contact aurfaee of nake-up area poeelbly more than offaeta thla difference. Taking Met* RCW. ' lM MUNS 099898 Charles R. Cucchsns to D. 3. Jennings April 7, 1972 ...Survey -a these things into consideration, one would not expect a new north ditch to solve the PCB abatement problem because it la expected that a new ditch would become contaminated quickly. Significant progress has been made in clean-up procedures which results In lower detection limits and fewer interferences. The detection limit for water samples In this series of analyses was 0.02 ppb. /bps Attachment Charles 1. Cutchens HONS 099699