Document DM9QNBzLeVkkQ1gzGbxXB61oa
| V-
r*
j; i
i-` j.
jl.i.';::'!
,i: '
!ih]j! ilh Hin '
Jj1:
Industrial Heating
i4fr Conditioning
Reznor Manufacturing Company
66 Union Street, Mercer, Pa.
Gas Unit Heaters--nine sizes: 25,000 to 250,000 Btu; Console-Type Room Heaters-- 25, 50,65 and 75,000 Btu; Duct Furnaces--50,000 to several million Btu; Gas Horizon tal Furnaces--75,000, 100,000 and 125,000 Btu.
Reznor Series DS Sectional Duct Furnaces 150,000 to Several Million Btu
Sectional assembly simplifies installa tion. Capacities totaling 2,000,000 Btu and above can be installed in custom engineered heating systems from sec tions weighing no more than 315 pounds. Unlimited number of sizes in steps of 50,000 Btu from 150,000 to several million Btu. All assembled from four basic sections--150, 200, 250 and 300,000 Btu.
Units are compact, highly efficient, lightweight heat exchangers, each with a full complement of combustion controls. For assembly with components for airmoving, cooling, cleaning and humidifi cation selected to meet the exact re quirements of each job. May also be used as booster units to supplement other warm air heating equipment.
Designed for installation as an integral part of the ductwork, all sections are equipped for either suspended or base mounting. Because air flow through the heater may be in either direction, sec tions can always be turned to provide easy access to controls and burners. To provide for seasonal operation of less than the total capacity, each section is complete with controls and built-in
draft diverter. The unit shown above is a 450,000 Btu
duct furnace (one 150,000 and one 300,000
Btu section mounted side-by-side). Be
cause sections can be mounted in a single bank or in a double bank, overall dimen
sions depend on the manner of installa tion. All sections are 37 in. high and 24 in. deep. Width varies according to capacity.
Gas and electrical controls are nor mally installed on the front of the heater, but can be relocated to the side if pre ferred. Controls include main and pilot shut-off valves, electric valve, pressure regulator, safety pilot and adjustable limit control. All controls supplied by leading manufacturers. All electrical components Underwriters' Laboratory ap proved.
Aluminized steel is the standard heat exchanger material; stainless steel heat exchangers are also available.
Built-in draft diverter is reversible so that flue connection may face in either direction. Flue collar on snap-out plate for easy adaption to vertical or hori zontal discharge.
Specifications--DS Duct Furnace Sections
Section
DS-150 DS-200 DS-250 DS-300
Btu Input
150.000 200.000 250.000 300.000
Btu Output
120,000 160,000 200,000 240,000
EDR
519 692 864 1038
Thruput-cfm
Minj- Maxiroumt mumtt
1200 1600 2000 2400
1S00 2400
3000 3600
High
37' 37' 37' 37'
Deep*
24' 24' 24' 24'
Wide*'
21H* 27 H' 35W' 40Ji'
Weight
190 lbs 235 lbs 275 lbs 315 lbs
' fCr'totaldtplk of multiple banks, aid depths ofsections, then aid If ifsections will be installed back-to-back,
or aid enouoh space to allow for removal of burners if units are to be snstxMei front-to-fronl or front-to-back. For total width of multiplesections, aid widths ofsections. For total width of duel on multiple sections sub-
tract tyi* from total overall width,
1282
A..lt
C_ ondltoni.nq
Industrial Heating Duct Furnaces
^ Unit Heaters
Reznor Manufacturing Company
66 Union Street, Mercer, Pa.
Check your local phone directory for your nearest Reznor distributor or district office
Methods of Installation--DS Series Duct Furnaces
This schematic diagram shows how Reznor Series
DS. Duct Furnaces may be combined in the duct system with' other com ponents. All components .shown (except the blower or other air-impelling
equipment) are optional, to be used only as re
quired by the specific job to be done. It is recom mended that cooling and humidifying equipment be installed downstream
Multiple-section single bank installation with common Multiple-section, double-bank installation with com
air supply and distribution ducts.
mon air supply and distribution ducts.
Reznor Gas Unit Heaters
Completely automatic heating for all commercial and in dustrial buildings ... as the basic system or to supplement other types of equipment. Eight sizes--25,000 to 200,000 Btu with choice of propeller fan or centrifugal blower plus 250,000 Btu twin-fan model. Aluminized steel heat exchangers. Cast iron universal burners. Built-in draft diverter. For complete details, dimensions and specifications write for Bulletin B-55-UH.
Reznor Series D Duct Furnaces
For residential and small commercial applications requiring a heat exchanger for use in a custom engineered system. Four sizes: 50, 75, 100 and 125,000 Btu. For installation with any combination of equipment for air moving, cooling, cleaning and humidification. Burner access and controls completely enclosed on same side of handsomely-styled cabinet. All models 22 in. wide by 23 in. high; depth varies with capacity. Complete with combustion controls and built-in draft diverter. For suspended or base mounting. Bulletin B-55-D.