Document DGzqKQZYj7D9BXnQrVLmV3an

in^eh-office memo TENHECO CHEMICALS, INC. To J. T. Sweeney At Flemington from C. Champion At Flemington suhject VCM Exposure Data - Flemington Plant Bendix Monitoring System Period; August 30, 1975 to September 5, 1975 date September 9, 1 Copy to W. D. Bord P. A. Lobo R.A, Lojewski -WOliringoff F, X, Ritter M, K, Rosen G. I, Rozand F. Toca Attached are area data summaries, summaries of excursions above 5, 25 and 100 ppm VCM and a listing of all excursions observed at or above 100 ppm VCM. Also included in this report and in all future reports is a summary of readings exceeding 1 ppm. Points #9 and 20 in the Reactor Building were removed from normal service on 9/2/75 and 9/5/75 respectively. These points are currently being used to define a clean air source for the proposed capsule in the Reactor Building. The Plant has been in operation seven days for this report period running at about 70% utilization. The following summaries are taken from a tabulation of 25% of the data or one set of readings per hour. The Reactor Building showed 552 readings > 1 ppm, 4 excursions "> 25 ppm and no reading 7 100 ppm. The Pilot Plant showed 317 readings > l ppm, 2 excursions 7" 25 ppm and no readings 7 100 ppm. The General Area showed 139 readings 7 1 ppm 9 excursions 7 25 ppm and no readings 7 100 ppm. The Lift Station showed 86 readings > 1 ppm, 2 excursions ^ 25 ppm and no readings 7 100 ppm. The Parshall Flume showed 12 readings 7 1 ppm and no excursions 7 25 ppm. All readings greater than or equal to 100 ppm are tabulated in Table IV. Nine readings at or above 100 ppm occurred during this report period reflecting four separate incidents. Three incidents occurred in the Reactor Building affecting the center aisle, stripper #1 platform, knock-out pots, day tank area and the west wall between the old styrene tanks. One incident occurred in the General Area affecting the tank car unloading area. No incidents occurred in the Pilot Plant during this report period. WCC;ms U- C-, cCtoww'^aM.y. Cjlftt) W. C. Champion COLORITE 006398 I REACTOR DUILDINC $-3oPeriod .Covered )/?-5~-7r 1 Monitoring' Point AJ . 1' Center Aisle Column fl2, 1st fir 2 Center Aisle Column jf-i, 1st fir 3 Center Aisle Column ij6, 1st i:lr f,24 il Slurry Trims lev lump, 1st fir 5 Slurry Trans lor Pump, 1st fir 6 Delbamer Tanks, 1st f.Lr 7 it'L Recovery Compressor Wall, 1st fir 8 jil Recovery Vacuum Seal Pump, 1st fir 9 * V'CM Day Tank Pumps, outside 10 Center Aisle .Column t'2, 2nd fir 11 Center Aisle Column i|4, 2nd fir 12 Ceiiler Aisle Column 116, 2nd fir 13 Stripper ii'2 Platform, manhole, 2nd fir 14 Panel Hoard Column i(7, 2nd fir IS Stripper Hat form, manhole, 2nd fir 16 Knock-Uut Pots, 2nd fir 17 West Wall lie tween bid Styrene Tanks, 2nd fir 18 South Wall Near Cclatin Make-Up Area, 2nd fir 19 Stairwell in Hallway, 2nd fir 20 Outside, near left side dopr to weigh tank 766. . rv6|:: as J/ti46Vt>5s% /S6o5 ~17//Z6tfi&1ta _7//T6c6ll M * ISo ... '.Total *' ' OU --0.7 0.6 0.6 o.5 0.6 1.3 c 0/..9 _ <WU3?..0/ /3 0.6 J.* U1.3. /6 2?./ 0.6 I.IZ >1 >5 Ill. I . J/O* 7. . /V <36, <& 76 /8 *33933.. 5? 50 5a 73. 19 1 <3 1 8 7 / 8 9 5 7 O. i 8 6 A3 3 Jd3- >35 O o o o o* o / o o A / o o o o o o o o o >/oo o o o o o o oonnaoo * <ooo o o o o o COLORITE 0 0 6 3 9 9 }' * I *1 R.A, Lojc 4/15/7 ' , lAULti II i ' * \. . PILOT PLANT iod Covered. S-3o/9-S*)S Period Dryer Lift Station (future) Pilot Laboratory Centrifuge NPU Reactor l-'ursliall flume Cooling Tower lump Switches Reactor "B,f x- "C" Reactors ... .---- --- ..... t*.------- --25-------r--- m---- / ***** . . > .' /6fc : O.X ' / Kb ~3Z 8b aU o-a ` O SOO O n <3 a , . . ' .- - M Kb 6.9, ... a <W-__ i * 0 0 /(,(* 6.8 . Mi 1--- -- a Kb :: "it /7 /./ . 19. s4 L 4 0 0 KL ll --m-- __ /=__ 4>9 SS 5 ~ r... 0 0 Total /66O /so itg cc / 0 0 0 a 0 0 0 0 0 COLORITE 006400 *. . , ii. -**i. J R.A. Lojewsk 4/15/75 I' I ABLE III .GENERAL AREA 'Period Covered , Monitoring Point *t :. ` Al ! _________ >7>JL>3S'>/PP 1 2 . Truck Loading Quality Control Laboratory) west- 3 4 Quality Control Laboratoryj east Lunchroom S 6 7 8, 190.` IJulU leading Tower Dryer Room hugging Seat Maintenance Shop . VCM Pumps Tank Cur Unloading Total JU, _ /d i7(>Ll /d /(*(o fLL /Uo O.'Sl 0.3 B <po.al .- o <0O.1.l o o <<o0..1t .. oo ?} 67 j-r SI oM J39 o 6 o o o o o 7%4T 63 *. oO.... a .o .O o.* o oo o -__ Qoa- 8o /o fO COLORITE 006401 % * > Vi l 1 i `i il r * R.A, LoJ 4/15/ F x CAlfCs | n< s AT ir>r> ppm n e Ra~f i? T) AT F -3o-l -3l-~jg' .... 0//O Onf* Of3 ofaf Of Of30 ; oi4l oi4 3 Area UJ/JUA #tW. OkHsryf{ri77**S jilft 0**T&t/)*Si cosiv*tr*2 / o?^ $( S^O<j m STAi?P4. w/ /jc*f7TrtA+Jn**., KtJ6CK OO-f PoTS ei 2>p Vest -pty Tfr**C aA/9 OtrTstbg /jfSk&j Ca/7 j/SX* CMW?^y $ t>p *t /}ctwy cost/?cj#i.k f /%. %#k7>o T/ HC. iWttvst $44, ">/? /M' %40f.r 9-5-?T ia*/^ TtihiH CA& u*jkaA'b***p. R-A.lW*?/75 COLOR!TE 006402