Document DGVroDBZDadJq0Y5ryBBpKx7d

frS ***) i . OPERATING DEPARTMENT HEAD 2. D. R. HALEY 3. K. H. TOWNBENA a. J. I... WYATT . PLAINTIFF'S EXHIBIT UC-1872 SHARE AUDIT PROCEDURE DEPT. JfeC6.)L&y_______ _________ ____ date__ .......... ........ ...................... DEFICIENCY exists YES---------- NO y^~ NAME OF PROCEDURE AEMJA&_LAMfAlJttfMtJLgTAcUR TvBss R E F E RENCE? ... .L.R&CAP- HlttUL&.L__________ NUMBER Or-" PERSONNEL INTERVIEWED:________________________________ - *N A. AWARE OF PROCEDURE'? B UNDERSTAND PROCEDURIr? C. FOLLOW PROCEDURE? D. IF NO, WHY NOT? E. REMEMBER HAVING RECEIVED TRAINING? 1.LAST YEAR 2.TWO YEARS AGO 3.THREE YEARS AGO UP TO BATE PROCEDURE IN APPROPIATE MANUAL? * ANY REI AT I ON TO A/I REPORTS IN LAST 6 MONTHS? SHOULD EXISTING PROCEDURE BE MODIFIED??IF YES EXPLAIN) SHOULD RETRAINING BE CONDUCTED? SHOO: if ANOTHER AUDIT BE CONDUCTED? vfb when?.... 3....M&dtT.d.*.____ AUDITED BY_1 APPROVED BJiY: BRE 0403 HEARING PROTECTION INSPECTION AND AUDIT UNIT/AREA/BLDG. INSPECTION BY /? BCfi V FFV__________ DATE A. AREA AND EQUIPMENT REQUIREMENTS YES 1. Are noise signs present if ^90 dB(A)? 2. Noise signs easy to spot. t/" 3. Noise signs legible. 4. Ear plug boxes near signs. 5. Sufficient ear plugs in boxes. 6. Ear muffs available. 7. Noisy stationary and portable equipment have signs 8. Noisy field operations (sandblasting) have signs. 1L NO SEE COMMENT (D HL A A B. PERSONNEL REQUIREMENTS 1. Know where noise areas are. 2. Know of available hearing protection devices. 3. Carry hearing protectors on their person. 4. Are wearing protectors (if needed). 5. Are properly trained. C. COMMENTS is t/ / / t/ i s / ~---f-Z.---/ / *---Lt-fi $16/4$: &i c$c fj> vnv; frl Tc stem pmm. BRc STF/m vm. frt TC STFFn PH'S. / ($) SIGNS AT AKF FAPFP.______________________ R) hSl WEST Bay WAS JF/iffy r/)FSF ARE Fib)Pines 6F A HFtM PrKEb A)0)SF SURVE/Y AbID rhE OFPFTFP NOISE MF?S UhlL RF FoRtAcoM/MG BRE 0404 fc ,r'-. . 4~ ' ^2ii> :}.jka%. ,sCjl**yi*wr>:: i BRE 0405 NOISE INSPECTION AND AUDIT UNIT/AREA/BLDG INSPECTION BY ft EM ME fry A. MEASUREMENTS 1. Is sound pressure level <90 dB(A)? 2. Is sound pressure level <115 dB(A)? 3. If >115 is action plan to reduce written? 4. Is calculated TWA <100%? 5. If TWA > 100% are engineering controls planned? 6. If TWA >100% are administrative controls used? 7. If TWA >100% is personal protection used? 8. Is area free of noisy leaks? 9. Is sound measurement equipment reliable? DATE f" / ? YES SEE NO COMMENT M_______ M 2 B. RECORDKEEPING 1. Are noise maps up-to-date? 2. Is noise data in computer records? 3. Is instrument calibration data adequate? C. COMMUNICATIONS 1. Is department head aware of problems? 2. Are attempts being made to solve problems? D. EQUIPMENT 1. Is old noisy equipment insulated properly? 2. Is new equipment specified for<90 dB(A)? ^_____________________ ___________ iX l/' jUl BRE 0406 NOISE INSPECTION AND AUDIT E. COMMENTS Page 2 9 BRE 0407 DETECTOR TUBES UNIT/AREA/BLDG INSPECTION AMD AUDIT ffry &DATE / -/ ? INSPECTION BY A. CHECK THE FOLLOWING TUBES FOR EXPIRATION DATE ITEM NO. DESCRIPTION MEASURABLE TUBE CONCEN STORE NO. TRATION CODE NO. QUANTITY CLOSEST LEXPIRED EXPIRATION eft BOXES DATE COMMENTS 1 ACETALDEHYDE(FORMALDEHYDE) 91 2-20 PPM 63141-005 2 ACETIC ACID 81 1-80 PPM 63141-003 0 Ava-ss y* 3 ACETIC ANHYDRIDE 4 ACETONE 5 AMMONIA 81 .5-40 PPM 63141-003 151 .01-2% 63141-023 3L 1-60 PPM 63141-007 1 0 Jan z 6 BUTANE 104 50-1400PPM 63141-009 7 CARBON MONOXIDE 8 CHLORINE 9 ETHYL ACETATE 10 ETHYL ALCOHOL 11 FORMIC ACID 12 HYDROGEN SULFIDE ILL 5-50 PPM 63141-011 8LA .3-16 PPM 63141-013 0 0CT-<63 l 141 .04-1.5% 63141-017 0 Joti-'x'f $7 112 .05-5% 63141-015 0 h------- :--r 81 1-80 PPM 63141-003' 4LL .5-60 PPM 63141-021 0 NOV z 13 ISOPROPYL ACETATE 14 METHYL CHLOROFORM 15 METHYL ETHYL KETONE 16 MONOETHANOLAMINE 17 TOLUENE 18 CHLOROTHENE 19 BUTYL ACETATE 2 O^hyL ISOPROPYL ETHER 21 BUTYL ESTERS 151 .05-0.75% 63141-023 135 100-500PPM 63141-025 152 .02-0.6% 63141-027 3L 2-30 PPM 63141-007 122 10-600PPM 63141-029 135 100-500PPM 63141-025 142 0.01-0.8% 161 0.04-1.0% 142 0.01-0.8% 0 K 0 T' * 5 3 Jan'S3 3 &\ 6 B. NO. OF DETECTOR TUBE PUMPS IN UNIT C. LAST CALIBRATION DATE ON PUMPS D. IS DEPARTMENT DOING MONTHLY AUDIT COMMENTS: _________________________ Z 5FF-?2 BRE 0408