Document DGV0MOqRnd1Mma8bDYNK4xKb5

DESIGN REPORT PART IV - POuER OIL SYSTEM POLYETHYLENE UNIT - PLANT CA WF-6038 C/a & / ' /-/2T-5 * . . .v C/ -^-2- 11 S'- /H >/ * t 6 -C7-SJ ( i &' i-55 // Written by: i* + Mr. F. F. Calloway^ y ' - - sr* jr~ / z_ - 3h- Supervised by: Mr. R. A. Prosser Reviewed by: Mr. G. J.. Hanks, Jr. Mr. C. G. Kncxvles GAR PROCESS ENGINEERING AND DEVELOPMENT DEPARTMENT CARBIDE AIID CARBON CH5KIC.-.LS CCLPANY SOUTH CHARLESTON. VEST VIRGINIA NOTE?PER II, 1952 0-1*7240 TABLE OF CONTENTS PAQE INTRODUCTION: SECTION I - PROCESS ......................................................... 1 LIST OF MAJOR EQUIPMENT.............................................................................. EQUIPMENT LIST.................................................................................................... LINE LIST............................................................................................................. VALVE LIST ............................................................................................................. MAJOR EQUIPMENT SPECIFICATIONS 3 1* 22 1*1* 6038E-U01 thru -1*10 and -1*71......................................................... 6038E-U01A thru -HlOA and -L71A.................................................... 6038E-U01B thru -l*10B.......................................................................... 6038E-U01C thru -2*10C.......................................................................... 6038E-U01E thru -U10E, -1*73 and -i*73A........................................ 6038E-U21 thru -1*25, -U76; -1*21A thru -1*2$A, -1*21B thru -1*25B, -1*21M thru -l*2$M and -1*78........................................ 6038E-1*31 thru -1*35 and -1*75......................................................... 6038E-2*31A thru -U35A.......................................................................... 6038E-1*1*1 thru -1*50.............................................................................. 6038E-U62.................................................................................................... 6038E-U63.................................................................................................... 6038E-U61*.................................................................................................... VALVE AND PIPING SPECIFICATIONS 73 73 76 78 79 81 85 85 87 89 91 93 l..................................................................................................................... ................... .h 5..................................................................................................................... 21..................................................................................................................... 125-lb Hydraulic Oil Service.............................. 300-lb Hydraulic Oil Service......................................................... . 2000-lb Hydraulic Oil Service ................... .......... Specifications for Protective Covering ................................... 95 96 97 98 99 101 103 105 SECTION II - EIECTRICAL.............................................................................. 106 Poirer Oil Control Circuit Block Diagram of Interlock System DRAWINGS Building Plan, H3B-B1587 .................................................................. Plot Plan, H3B-B1358-2 Circuit Diagram, H3B-B1359-1 Intensifier Control Relay Assembly (Electrical) SK-56U58 (Replaces SK-50889)................................................. 110 Ill 112 113 017241 TABLE OF CONTENTS (CCNT'D) PxiGE D.iiJUIHGS (CONTD) Intensifier Control Schematic Wiring Diagram (Electrical) SK-50890 ................................... ;................................................................ llL Block Diagram, Electrical Connections - Polyethylene Unit (Electrical) SK-50891 .......................................................................... 115 Flair Diagram, H3B-R1044 .................................................... ......................... 116 017242 1 DESIGN REPORT PART IV - PGKER CEL SYSTEM POLYETHYLENE UNIT - PLANT CA WP-6038 INTRODUCTION This report contains two sections. Section I covers the equipment, instruments, piping, and valves necessary for the installation of the Power Oil System for the Polyethylene Unit at the Seadrift Plant, Section II contains detailed specifications for all special components of the electrical control system which coordinates the Power Oil System and the High Pressure Pumping System, Section II also contains a block diagram of the cornslete interlock system for the entire Polyethylene Unit and detailed wiring diagrams for the control circuit on the Power Oil System, The Paver di System consists of five hydraulic pumping units. Each unit comprises two pairs of Vickers variable delivery piston pumps, one 700-hp double shaft extension synchronous motor for each pair of pumps, two six-inch solenoid-operated four-way valves, and one hydraulic paver unit complete with accessories. Each of the five hydraulic pump ing units operates in conjunction with five high pressure intensifiertype pumping units covered in Design Report, Part III, WP-6037. The five hydraulic pumping units arc housed in the north side of the High Pressure Pump Building. This side of the Pump Building shall be completely enclosed and shall contain unit heaters of capacity sufficient to keep the inside temperature above the outside ambient during cold weather or at anytime the motors arc shut down. Equipment layout and process pipng shall follow the pattern established in Design Report, Part m, '.VP-6037, covering the High Pressure Pumping System. Special provisions shall be taken m designing the equipment foundations and piping supports to withstand the sometimes severe vibratory loads of the hydraulic oil piping. The pipe supports shall utilize wooden blocks similar to those shown on C&GCC Drawing .-253l60 with anchors si".liar to C&CuC Drawing A--258138. The sub-floors in both the Paver Oil Room and the High Pressure pump Room shall be sloped to floor drains for the collection of oil leakage. These drains shall be run to a common header and thence to an under ground tank located in the yard area at the west end of the High Pressure Pump Building, An underground storage tank for clean hydraulic oil will be located in this same area. The operating floor in the Paver Oil Room shall be made of galvanized steel grating in conformance with CcCC Standard S-148. 017243 2 INTRODUCTION (CONTD) Peep-holes through the fire wall similar to those on C&CCC Drawing A-253140 shall be located at eye level ana arpraximately in the center of the bay at each unit. An instrument panel for ten alarm signal lights, 6C38E-421K through 6038E-425K and 6038E-421R through c038E-425R, shall be located in the Power Oil Roots approximately centered along the north wall. Lighting intensity in the Paver Oil Room shall conform with that given or CCC Standard EL-149 for Compressor Rccm and fixtures shall coniorm generally with C&CCC Standard EL-105 for hazardous locations. Yard lighting shaJl be in conformance with CiCCC Standards EL-103 or EL-104 with the choice dictated by the particular area to be lighted. Elec trical grounding shall conform with C&CCC Standard EL-5. The paver supply to the 700-hp motors shall be interlocked with the Auxiliary Gas Supply System as described on page 3 of Design Report, Part VIII, VifP-6043, for said system. The paver supply to the 700-hp motors shall also be interlocked with the respective supercharge pump motor (6G38E-421B, etc.) and coolant pump motor (6038E-431A, etc.) so that it may not be started unless both auxiliary pumps are running and will stop if either auxiliary pump stops. Start - stop switches for each of the supercharge pump motors and each of the co lant pump motors shall be provided as follows: (1) One switch for each motor located on the north wall of the Power Oil Room opposite each pumping unit. (2) One switch for each motor located on a panel on the fire wall in the High Pressure Pump Room opposite each unit. The motors may be operated from either location. Start - stop switches for the 700-hp ...otors shall be provided as f ollcws: (1) One emergency stop switch to stop both motors located in the Reactor Control Room on the respective Reaction Cell Panel, (2) One emergency stop switch to stop both motors located on the north wall of the Paver Oil Room opposite each unit. 0) Cnc start - stop switch for each motor located on a panel on the fire wall in the High Pressure Pump Room opposite each unit. These r switches are to be wired so that each motor may be started indepen dently but both motors will be stopped by either switch. 017244 3 LIST OF MAJOR EQUIPMENT FIart Diagram K35--RIOlilj 6038E-401, -4014 thru -410, -410A 6038E-40IB thru -410B Hydraulic Oil Pumps 700-hp Synchronous Motors ^ 6038E-401C thru -410C Hydraulic Oil Pump Base Plates 6038E-4013 thru -410E 6" Solenoid-Operated Four-tVay Valves ' 6038E-421 thru -425 Supercharge Pumps 6038E-421A thru -425A 6038E-42IB thru -425B Hydraulic Oil Reservoirs 50-hp Electric Motors ^ 6038E-421C thru -425C 2" Solenoid-Operated Four-'.Vay Valves 6038E-421M thru -425M Pilot Oil Pumps 6033E-431 thru -435 Sp Coolang Oil Pumps 6038E-431A thru -435A Electric Motors 6038E-441 thru -450 Oil Coolers 6038E-461 Overhead Crane (Not shown on flcr.v diagram) 6038E-462 Clean Oil Storage Tank 6038E-463 Dirty Oil Storage Tank 6038E-464 'i 6038S-471, -471A Centrifugal Oil Separator Hydraulic Oil Pumps 6038E-473, -473A 6" Sclenoid-Oporatcd Four-way Valves 603SE-475 6038E-476 Cooling Oil Pump Supercharge Pump 6038E-477 2" Solenoid-Operated Four-fray Valve 6C38E-478 Pilot Oil Pump 017245 h EQUIPMENT UST Flow Diagram H3B-R1044 Unless H3B Department is to direct purchase, all items Trill be billed from information provided in this design report. 60383-401 THRU -110 - HYDRAULIC OIL PUMPS Ten (10) Vickers Model No. FV-2500-FHE variable delivery piston pumps for clockwise rotation. For complete specifications, see page 73. K3B Department to direct purchase. Item No. Property Mo 603SE-401 6038E-402 60383-403 6038E-404 6033E-405 6038E-406 6038E-407 6038E-408 60383-409 6038E-410 CA-6306-118 CA-6306-119 CA-6306-120 CA-6306-121 CA-6306-122 Grt-6306-123 CA-6306-124 CA-6306-125 CA-6306-I26 CA-0306-127 6038E-401A THRU -410a - KiDRAUUC OIL PUMPS Ten (10) Vickers Model No. FV-2500-FHE-LK variable delivery piston pumps for caunter-clockwise rotation. For complete specifications, see page 73. H33 Department to direct purchase. Item No. Property No 6038E-40U 6038E-402A 6038E-403A 6C36E-4.Q4A 6038E-405A 603SE-406A 603SS-407A 6038E-408A 6033E-4C9A 603S3-410A CA-6306-128 CA-6306-129 CA-6306-130 C.-.-6306--131 CA-6306-132 CA-6306-333 C--6306-134 CA--6306-135 1.-6306-136 CA-6306-137 017246 5 6038E-401B THRU -410B - SYNCHRONOUS MOTORS Ten (10) 700-hp, 720-rpm, 4160-volt, 3-phase, 60-cycle synchronous motors. For complete specifications, see page 76. H3B Department to direct purchase. Item No Property No. 6038E-401B 6038D-402B 6038E-403B 6038E-404B 6038S-405B 60383-406B 6C3SE-407B 6038E-408B 6038E-409B 6038E-410B CA-6213-208 CA-6213-209 CA-6213-210 CA-6213-211 CA-6213-212 CA-6213-213 CA-6213-214 CA-6213-215 CA-6213-216 CA-6213-217 6038Z-A01C THRU -41QC - HYDRAULIC CEL PUMP BASE FLATES Ten (10) hydraulic pump and motor base plates. Underside of base plate to be packed with sound absorbent material to minimize noise. For complete specifications, see page 78. H3B Department to direct purchase. 603SE-401D THRU -41QD - HYDRAULIC OIL ACCUMULATORS Ten (10) Vickers Model Al-2050-10 hydraulic oil accumulatorsj 3,000 lb per sq in. working pressure, gas-oil capacity 2,050 cubic inches. Refer tu detailed specifications on page 81, reference number (16). H3B Department to direct purchase. Item No. Property No. Location 603C2-401D 6038E-402D 6038E-403D P038E-404D 6G38S-405D 6038E-406D 603SZ-407D 603 SE-408D 6C38E-4C9D O03SE-41QD 0^-6476-105 CA-6476-106 CA-6476-107 CA-6476-108 CA-6476-109 ^ A--6476--110 CA "6476-Hl CA-6476-I12 CA-6476-113 CA--6476--114 H-421 H-431 H-422 H-432 H-423 H-433 H-424 H-434 H-425 H-435 017247 6 60385-401E THRU -41CE - FOUR-WAY VALVES Ten (10) six-inch pilot-operated, four-way valves, Vickers Model No, E0-10968-E. For complete specifications, see page 79. H3B Department to direct purchase. Item Nc. Property No 603SE-401E 6038E-402E 6038E-403E 6038E-404E 6038E-405E 6038E-4O6E 603SE-407E 6038E-408E 6038E-409E 6038E-410E CA-630S-33 CA-6308-34 CA-6308-35 CA-6308-36 CA-6306-37 CA-6308-38 CA-6308-39 Cfi-6308-40 CA-6308-41 CA-6308-42 6Q38E-401E-1 THRU -41CE-1 - SQIENaiD-OPElATED PILOT FOUR-WAY VALVES ^ Ten (10) 1/4" solenoid-operated pilot four-way valves, Vickers Model No. DG4S4-Q22-20, and sub-plates, Vickers Model No. DGSM-02-10. See specifications for Items 6038E-401E thru -410E. These will be located on the fire '.Tall in the Power Oil Room opposite the respective units. H3B Department to direct purchase. 6038E-40IS-2 THRU -410E-2 - SOIENOID AND BRACKET ASSEMBLIES (Not shown on flow diagram) Ten (10) solenoid and bracket assemblies for Items 6038E-401E-1 thru -41CE-1. To be used as spares. See specifications for Items 6038E-402E thru -410E. H3B Deportment to direct purchase. 6038E-401F THRU -410F - SIGHT FLQ.V INDICATORS Ten (10) Wa. W. Nugent Company 3" Figure 1366T cast iron sight flow indicators with 3" IPS threaded ends, and painted finish. Locations follow: Item No. Location 603SE-401F 6038E-402F 6038E-403F 6038E-404F 6038E-405F H-461 H-461 K^462 H-462 H-463 017248 7 603SE-401F THRU -41QF - SIGHT FLOW INDICATORS (CONT'D) Item No. Locat: 6038E-406F 6038E-407F 6038E-408F 6038E-409F 6038E-410F H-463 H-464 H-464 H-465 H-465 6038E-401 THRU -^41QG - PRESSURE GAUGES Ten (10) Vickers Model No. GS-3000 pressure gauges. Items 6038E-401G, -403G, -405G, -407G, and -409G located on H-401 thru -405 respectively. Items 6038E-402G, -404G, -4060, -408G, and -410G located on H-411 thru -415 respectively. Refer to detailed specifications on page 81, reference number (15). H3B Department to direct purchase. 6.33E-401H THRU -410H - SIGHT FLGff INDICATORS Ten (10) sight flow indicators, duplicates of Items 6O38E-401F thru -410F. Locations f ollcw: Item No. Location 6038E-401H 6038E-402H 6038E-403H 6038E-404H 6038E-405H 6038E-406H 6038E-407H 6038E-408H 6038E-n409H 6038E-410H H-451 K-451 HwV52 H-452 H-453 H-453 H-454 H-454 H-455 H-455 6038E-40U THRU -410J - THERMOCCPHE YELL aSSE&BLIES Ten (10) thermocouple assemblies. Tc be connected to Item 6037E-352, For connections and switch designations see Item 6037E-352, Design Report, Part III, High Pressure Pumping System. Specifications Type Thermocouple Assemblies Embedded bayonet thermocouple per Drawing TE-2678-L. 017249 8 603SE-AQU THRU -410J - THERMOCOUPLE 'TELL ALSEMBUES (CONTD) Specifications (Cont'd) Element Adapter Insertion depth, "X" dimension Flexible metal amor Copper-< cnstantan Stainless steel, TA-2670, 3/8-24 NF-3 threads 14-1/2" 28" long Assembly per Drawing A3E-E121 to include tube adapter and thermocouple head. Manufacturer Revere Corporation 1S-8 Cr-Ni steel separable socket 12" below 1" mounting thread to be supplied by purchaser per Drawing A3E-E151-\^ type 1. for field installation supply adapter for 3/8 NF-3 thread to 3/4" pipe thread. Installation Notes: Head to be mounted on end of rigid conduit at a distance of not more than two feet from point of temperature measurement. Locations are given in the following table: Item No, Location Nameplate 603SE-401J 6038E-4Q2J 6038E-403J 6C33E-404J 6038E-4Q5J 6038E-406J 6033E-407J 6033E-408J 6038E-409J 603SE-410J H-401 H-411 H-4G2 H-412 H-403 H-413 H-404 H-414 H-405 H-415 Discharge West Nc. 1 Vickers Discharge East Nc. 1 Vickers Discharge West No. 2 Vickers Discharge East No. 2 Vickers Discharge West No. 3 Vickers Discharge East No. 3 Vickers Discharge West No. 4 Vickers Discharge East No. 4 Vickers Discharge West No. 5 Vickers Discharge East No. 5 Vickers 6038Z-4JU-1 -- IHZRhGCOUFLE IFLJXYIRE (Not shown on flow diagram) Scecifications Type Insulation Length Manuaacpurer No. 20 3&S gage copper-constantan Polyvinyl each vrire; weatherproof braid overall To be supplied later Industrial Pyrometer and Supply Company Installation Note: To connect thermocouples. Items 6038E-40U thru -410J, to indicating potentiometer. Item 6037E-352. 017250 9 6038E-A01K THRU -4J-0K - FORGE ASSEMBLIES To be fabricated in the field per Drawing D-199612 using No. 70 orifice nipples and 0 - 100 psi range pressure gauges. To pass 20 scfh air with 50 psi upstream and atmospheric pressure downstream. Install in line AA-402 to Items 6038E-40IB thru -41GB per Drawing D-199612 far air purge on collector rings of electric motors. 6038E-401L THRU -410L - PRESSURE GAUGES Ten (10) Vickers Model No. GS-3000 pressure gauges. Install on Items 6037E-301 thru -305 and 6037S-301A thru -305A respectively. Refer t`o detailed specifications on page 81, reference number (15). H3B Department to direct purchase. 6038S-A01M THRU -410M - LIMIT SWITCHES (Not shown on flow diagram) Ten (10) Micro Switch Company Model EX-AR explosi .jn-preaf limit switches. M.unt on high pressure intensifiers, Items 6037E-301, -301A thru -305, -305A, under supervision of the Operating Department. Refer to Section II for wiring diagram. 6038E-A01N THRU -41CN - LX'IT SWITCHES (Not shown on flow diagram) Ten (10) Micro Switch Company Model EX-AR-30 explosion-proof limit switches. Mount on high pressure intensifiers. Items 6037E-301, -301/* thru -305, -305A, under supervision of the Operating Department. Refer to Section II for wiring diagram. 603SE-4Q1-0 THRU -410-0 - NOT USED 6038E-401P THRU -410P - SEE ELECTRIC/*! SECTION 6038E-411 THRU -420 - NOT USED 6038E-421 THRU -425 - SUPERCHARGE PUMPS Five (5) Vickers Model No. VF3-60-60-M pumps, to be located on Items 603SE-421A thru -4254. For complete specifications, see page 81. H3B Department to direct purchase. Item No. Property No. 6038S-421 6038E-422 6038E-423 6033E-424 6038E-425 CA-6306-138 CA-6306-139 CA-6306-140 CA-6306-141 c*.--6306--142 017251 10 6038E-421A THRU -425A - HYDRAULIC OIL RESERVOIRS Five (5) 700 gallon atmospheric working pressure hydraulic oil reservoirs. For complete specifications, see page 31. H3B Department to direct purchase. Iter. No. Property No. 6038E-421A 6038E-422A 6038E-423A 6038E-424A 6038E-425A CA-6392-262 CA-6392-263 CA-6392-264 CA-6392-265 CA-6392-266 6038E-42L3 THRU -425B - 50-HP ELECTRIC MOT CHS Five (5) 50-np, 1200-rpn, 440-vult, 3-phase, 60-cycle explosin-preof motors for Class I, Group D installation. To be supplied with Items 6G38E-421 thru -425. H3B Department to direct purchase. Iter. Ho. Property No. 6038E-421B 6038E-422B 6038E-423B 603SE-424B 6038E-425B CA-6213-218 CA-6213-219 CA--6213-220 CA-6213-221 CA-6213-222 603SE-421C THRU -425C - SOIZNCID-OPEr^TSD FOUH-VAiY VALVES Five (5) Vickers Model No. DF5S4-160C-20, 2" solenoid-operated four-way valves. Refer to detailed specifications on page 81, reference number (5). H33 Department to direct purchase. Item No. Property No. 6C3SE-421C 6038E-422C 6038E-423C 6038E-424C 6038E-^25C 6038E-421E THRU -425D - VENTURI FILTERS CA-6308-43 CA-6308-44 CA-6308-45 CA-6308-46 CA-63OS-47 Five (5) Vickers Model No. 0F1-16-30, 2'1 Venturi filters. Install in 2" lines HH-461 thru HH-465 respectively. Refer tc detailed specifi cations ,on page 81, reference number (13)* H3B Department tc direct purchase. 017252 11 6038E-42IE THRU -4255 - VENTURI FILTERS Five (5) Vickers Model No. QF1-06-20, 3/4" Venturi filters. Install in 3/4" lines HH-421 thru -425 respectively. Refer to detailed speci fications cn page 81, reference number (12). H3B Department to direct purchase. 6038E-421F THRU -425F - PRESSURE GAUGES Five (5) Vickers Model No. GS-1200 pressure gauges. Install in 2" lines HH-461 thru HH-465 respectively. Refer to detailed specifications on pare 81, reference number (11). H3B Department to direct purchase. 6038E-421G THRU -425G - PRESSURE CL.UGES Five (5) Vickers Model No. GS-1200 pressure gauges. Install in 3/4" linesHH-421 thru HH-425 respectively. Refer to detailed specifications on page 81, reference number (11). H3B Department to direct purchase. 6038S-421H THRU -42:"" - SIGHT FLO1.' IHDI&JCBS Five (5) >/m. W. Nugent Company 1-1/2" Figure 1366T plain sight flowindicators with polished brass finish. Install in lines HHH-441 thru HHH-445 respectively. 6038E-42U THRU --425J - LiQj-D LEVEL aLARHS (Not shewn on flow diagram) Five (5) liquid level alarms, to be mounted in hydraulic oil reservoirs. Items 6038S-^421i thru -4254. Specifications Type Model Operating conditions Liquid gravity Construction Manufacturer IAouid Level Alarm A-25-ST-EP 54C, atmospheric pressure 0.85 at 54C 3ronze body with 2-1/2" thread for horizontal mounting. Stainless steel float rod and float. Explosionproof cover. Jo Bell Froducts, Inc. Furnish as par Specification. 017253 12 6038E-421K THRU -425K - ALARM SIGNAL (Not shewn on flow diagram) Five (5) lights actuated by Items 6038E-42U thru -425J respectively with specifications as follows: Type Located Nameplates Two lights in parallel Off - indicating normal Oh - red, indicating abnormal Panel in Power Oil Roam Low Oil - No. 1 thru No. 5 respectively 6038E-42.1L - AL-'.RM HCRN (Not shown on flow diagram) . - One (1) liom to bo actuated by any one of the following: Items 6038E-42U and R thru -425J and R and 6037E-358 thru--361. Horn to be installed with re-set and located in the High^Fressure Pump Room 6038E-422L THRU 425L - NOT USED 6038E-421LI THRU -*425M - FI LOT OIL PUMPS Five (5) Vickers Model No. V-124-10-LH pumps to be located on Items 6Q38E-421A thru -^425A. For complete specifications, see page 81. H33 Department tu direct purchase. Item No. Property No. 6038E-421M 6038E-422M 6038E-A23M 6038S-424M 6038E-425M CA-6306-148 CA-6306-149 CA-6306-150 CA-6306-151 CA-6306-152 6038E-421N - SIGNAL UGHT (Net shown on flaw diagram) Type Located Service Nameplate actuated by Two lights in parallel Off - indicating normal On - red, indicating abnormal Master panel in High Pressure Pump R,am To indicate low oil level in any of the hydraulic oil reservoirs Low Vickers Oil Items 6038E-421J thru -425J 6038E-422N THRU -425N - NOT USED 6C38E-421-0 THRU -425-0 - NOT USED 017254 13 6038E-421P - RE-SST BUTTON (Not shown on flow diagram) To functi n so as to permit silencing of horn, Item 6038E-421L, with lights left burning to indicate source of tr.-uble. Note: lights to c ntinue burning until trouble has been c orrected at which time alarm circuit will re-set itself automatically. 6038E-422P THRU -425P - NOT USED 6038E-421Q - PQVER-CN LIGHT (Not shown ^n flow diagram) One (1) light t: indicate whether or not paver is on the level alarm systems. Items 6038E-42U and R thru -425J and R. Type Two lights in parallel On - green, indicating normal Off - indicating abnormal 6038E-422G THRU -425Q - NOT USED 6Q38E-421R THRU -425R - LIQUID IEVEL ALARL5 (Net shown on flow diagram) Five (5) alarms duplicating Items 6036E-42U thru -425J. To be mounted on Items 6038E-421A thru -425A and serve as high level alarms and actuate alarm lights. Items 6038E-421S thru -425S respectively. Any of these alarms will also actuate alarm horn. Item 6038E-421L, and alarm light. Item 6033E-421T. 6038E-42IS THRU -425S - .-.L--Rl1! LIGHTS (Not sham cn flow diagram) Five (5) lights duplicating Items 603SE-42IX thru -425K and actuated by Items 6038E-42IR thru -425R respectively. Located Nameplates panel in Power Oil Roam High Oil - No. 1 thru No. 5 respectively 6038E-421T - SIGNAL UGHT (Not shown on flow diagram) Duplicate of Item 6Q38E-421N. Located Service Nameplate Actuated by 6038E-422T THRU -425T - NOT USED Has ter panel in High Pressure Pump Room To indicate high oil level in any of the hydraulic oil reservoirs High Vickers Oil Items 6038E-421R thru -425R 6038E-426 THRU -430 - NOT USED fat?.`/J/U Ttf/?k 0fl 017255 lh 6038E-431 THRU -435 - CEL PIMPS Five (5) pumping units to be billed from t.is design report per speci fications on page 85. Item No. Property No. 6038E-431 6038E-432 6038E-433 6038E-434 6038E-435 CA-6306-143 CA-6306-144 CA-6306-145 CA-6306-I46 CA-6306-147 6038E-431A THRU -435A - EIECTRIC UOTCRS Five (5) electric motors to drive pumps. Items 6038E-431 To be billed from this design report per specifications Item No. Property No. 603SZ-431A 6038E-432A 6038E-433A 6038E-434A 6038E-435A CA-6213-223 CA-6213-224 CA-6213-225 CA-6213-226 CA-6213-227 6038E-431B THRU -4353 - BASE PLATES Five (5) base plates for pumps and motors. Items 603SE-431 and -431A torn 6038E-435 and -435A. Included with pump specifications on page 6038S-431C THRU -435C - CIL FILTERS Five (5) filters with following specificatiais: Cuno Engineering Corporation Auto-Klcan No, AK-233, Type EGIF-3 Material Filter clement Connections Standard Material - stainless steel Length - 8" Spacing - 0.008" Inlet and outlet - 2" flanged Drain - 3/4" IPS Locations and property numbers follow: Item No. Location Property No 6038E-431C 6038E-432C 6038E-433C 6038S-434C 6038E-435C HHH-481 HKH-482 HHH-483 HHH-484 HHH-485 CA-6311-27 CA-6311-28 CA-6311-29 CA-6311-30 CA-6311-31 017256 15 60385-436 THRU -440 - NOT USED 60385-441 THRU -<50 - CELL COOLERS Ten (10) oil coolers in accordance with detailed specifications an wage 87. H3B Department to direct purchase. Item No. Property No. 6038E-441 60385-442 60385-443 6C3SE-444 60385-445 60385-446 60385-447 60385-448 6038E-449 60385-450 CA-6376-327 CA-6376-328 CA-6376-329 CA-6376-330 CA-6376-331 CA-6376-332 CA-6376-333 CA-6376-334 CA-6376-335 CA-6376-336 6 / 6038E-441A. -443A. -445A. -447A. AND -449A - STRAINERS Five (5) strainers as follows: Leslie cast iron or equivalent Working pressure Size Connections Screen 250 psi at 450eF 3" Screwed Lionel with 0.0451 perforations Install in WWWW-401 thru YfiTVJW-405 respectively. 6038E-451 THRU -460 - NOT USED 6038E-461 - OVERHEAD CRANE (Not shewn on flew diagraa) Property Nos. s Crane - CA-&SSO-8 Crane Hoist - CA-6514-8 One (1) double girder, overhead, handpewer, traveling crane of five (5) ton capacity for standby service. To have anti-friction bearings, hand-operated trolley, and hand-operated chain hoist of five (5) tons capacity. Runway and rails shall be furnished by Purchaser and installation shall be similar to C&CCC SK-54208B (not included in this report). Crane shall serve entire length of Power Oil Room. 017257 16 6038E-462 - CLEAN OIL STORAGE TANK Property No. C/.-o392-2^7 One (1) 72" CD x 26 - 0" overall length, 50 psi working pressure vessel. For complete specifications, see page 89. This will be installed undcrgro md with coating per Protective Covering Specifi cations on page 105. H3B Department to direct purchase. 6038E-462A - SLIP GAUGE One (1) slip gauge fabricated in accordance with SK-27349 (not included in this report). Install in oil storage tank, Item 6038E-462. 6038E-462B - PRESSURE GAUGE One (1) pressure gauge as follows: Ashcroft No, 1219k with white dial. Dial size Range Connection located Mounted 0 --eu' psx Bottom AA-406 Equipment 6038E-462C - PRESSURE REDUCING REGULATOR e, c ntrol downstream pressure in air line 1" AA-406. X S os cificati ans Type Connection, size' ^ Orifice size Pressure, upstream dorms trean Material Manuf acturer 603BE-462D - RELIEF VaLVE 630 1" IP size 1/2" diameter 90 psi 17 tc 30 psi \ Cast iron ''Fisher Governor Company \ One (1) 1" Lunk Figure 1045 relief valve set at line AA-406. psi. Install on 6038E-462E - (EL FiUER Property No. CA-6311-3h One (1) filter as follows: Cuno Engineering Corporation *.uto-Klean No. AK-220, Type EGL 017258 17 Revised 1/4/54 6038E-462E - OIL FILTER (COHT'D) Material Filter element Inlet and outlet Standard Material - stainless steel Length - 6" Spacing - .015" 1-1/2" IPS Note: Install in HH-491. 6038E-462F - POSITIVE DISPLACEMENT METER To meter flow in hydraulic oil supply line HH-491. Specifications Type Connections Flow conditions Register Model No. Manufacturer Positive Displacement Meter 1" female pipe thread 20 to 25 gpm of oil at 25 psig; 300 SSU viscosity Vertical type in gallons ER-23 Pittsburgh Equitable Meter Company Furnish as per Specification. 6038E-U63 - DIRTY OIL STORAGE TANK Property No. CA-6392-268 One (l) 4' - 0" OD x 12' - 6" overall length 50 psi working pressure vessel. For complete specifications. Bee page 91. This will be installed underground with coating per Protective Covering Specifi cations on page 105* H3B Department to direct purchase. 6038E-463A - PRESSURE INDICATOR RECEIVER Property Ho. CA-6332-492 (R) To indicate level in dirty oil storage tank. Item 6O38E-463. Mounted Nameplate Panel in High Pressure Pump Room Dirty Oil Tank Liquid Level Specifications Range, scale Pressure element Manufacturer 0 to 50 inches of water Receiver hydron The Foxboro Company Furnish as per General Specification Forms A3E-F1 through A3E-F20 incl. Installation notes: Connect to transmitter 6038B-463A-1. 017259 18 Revised 1/4/54 6038E-463A-1 - FLOW TRANSMITTER Property No- CIA-633^-28^ (A) Spec Ifications' Range Manometer: material, body material, element Connections Manufacturer 0 to 50 inches of vater Dry type for 750 psi working pressure Steel Z-nickeil 1/4 inch HPT The Foxboro Company Furnish as per General Specification Forms A3E-F1 through A3E-F20 incl. Installation notes: Install with gas blovback. Connect to receiver 6038E-463A. 6038E-463B - PRESSURE GAUGE One (l) pressure gauge as follows: Ashcroft Ho. 1279A with white dial. Dial size Range Connection Located Mounted 4-1/2 0 --erpsi Bottom AA-407 Equipment 6038E-U63C - RELIEF VALVE & Duplicate of Item 6038E-462D. Set at 30' pslg. Install on AA-407* 6saSE-ii6-;D - rmiGoiinE repocuto BEOUiAian -> - DupliCfltr* nf ftem ~hTmi Li'ftl diiLm-ct-rnnm proflgirra in AA-40'fT' 6038E-463E - OIL FILTER Property Ho. CA-6311-33 One (l) filter as follows: Cuno Engineering Corporation Auto-KLean No. AK-220, Type EGL. Material Filter element Inlet and outlet Note: Install in HH-404. Standard Material - stainless steel Length - 8" Spacing - .015" 1-1/2" IPS 017260 6038E-464 - CEN'iRIFUGAL OIL SEPARATOR (Not shown on flow diagram) Property No. CA-6311-32 Motor Property No. CA-6213-228 One (l) Model No. 45-25P DeLaval Portable Uni-Matic Centrifugal Oil Purifier. Included as accessories are two (2) 20 ft lengths of 3/4" oil resistant TP > ** --o --V.- -- T. !> ~ " 19 Revised 5/12/54 6038E-U65 - PRESSURE REDUCING REGULATOR Install in line PP-4o8. (A) Specifications Type Connections, size Orifice, size Pressure, upstream downstream, range Material, 'body- inner valve Manufacturer 630 1-inch IPS 1/8 inch diameter 600 lb per sq in. 46 to 95 lb per sq in. Cast steel/cast iron 18-8 Cr-Hi steel Fisher Governor Company 6038E-465A - PRESSURE GAUGE Ashcroft 1279A, 4-1/2" white dial, range 0-100, bottom connection. Install in line FP-408 downstream of Item 6038E-465. (A) 6038E-465B - RELIEF VALVE (A) 1" Lunkenheimer Figure 1045 relief valve set at 50 psi. Install in line PP-4o8 downstream of 6038E-465. 6038E-466 - HYDRAULIC OIL ACCUMULATOR (Not shown on flow diagram) Property No. CA-6476-115 Duplicate of Item 6038E-401D. To be used as spare. Refer to detailed specifications on page 8l, reference number (l6). H3B Department to direct purchase. 6038E-467 - VENTURI FILTER (Not shown on flow diagram) Duplicate of Item 6038E-421D. To be used as spare. Refer to detailed specifications on page 8l, reference number (13). H3B Department to direct purchase. 6038E-468 - VENTURI FU'lllt (Not shown on flow diagram) Duplicate of Item 6038E-421E. To be used as spare. Refer to detailed specifications on page 8l, reference number (12). H3B Department to direct purchase. 6038E-469 AND -469A - PRESSURE GAUGES (Hot shown on flow diagram) Duplicate of Item 6038E-421F. Two (2) pressure gauges to be used as spares. Refer to detailed specifications on page 8l, reference number (11). H3B Department to direct purchase. 017261 19A Added 5/12M 6038E-470 THRU -klOC INCL. - PRESSURE GAUGES (Not shown on flow diagram) Duplicate of Item 6038E-^01G. Four (k) pressure gauges to be used as spares. Refer to detailed specifications on page 8l, reference number (15) H3B Department to direct purchase. 6038E-U7I ~ HYDRAULIC OIL PUMP (Not shown on flow diagram) Property No. CA-6306-153 Duplicate of Item 6038E-J4OI. To be used as spare. For complete specifications see page 73 H3B Department to direct purchase. oil161 20 6038E-471A - RURAL IIC OIL PULiP (Not shewn on flew diagram) Property No. CA-630^154 Duplicate of Item 6038E-401A. To be used as spare. For complete speci fications, see page 73* H3B Department to direct purchase* 6038E-473 AND -473A - SOLEHQID-OFERATED FOUR-WAY VALVES (Not shown on flat Property Nos, CA-6308-48 diagram) CA-6308-49 Duplicate of Item 6C38E-401E. To be used as spares. For complete speci fications, see page 79. H3B Department to direct purchase. 6038E-473-1 AND -473A-1 - SOLENGED-OPSRATED PILOT FOUR-Y.'AY VAL75S (Not shown on flow diagram) Duplicate of Item 6038E-401E-1. To be used as spares. See specifications for Items 6038E-401E thru -41QE. H3B Department to direct purchase, 6038E-474 - NOT USED 6038E-475 - OIL PUHP (Not shewn on flow diagram) Property No, Ca^o306-155 Duplicate of Item 6038E-431. To be used as spare. For complete speci fications, see page 85. 6038E-476 - SUPERCHARGE PUMP (Not shown on f low diagram) Property No, CA-6306-156 ` Duplicate of Item 6038E-421 but with half-coupling only. To be used as spare. For complete specifications, see page 81. H3B Department to direct purchase. 6038E--477 -- SCLZaQID-QFERjtTZD FOUR-WRY VAL7E (Not shown on flow diagram) Property No. 04-6306-50 Duplicate of Item 6038E-421C. To be used as spare. Refer to detailed specifications on page 21, reference number (5). H3B Department to direct purchase. 017263 21 Revised 5/12M 6038E-U78 - PILOT OIL POMP Property Ro. CA-6306-157 Duplicate of Item 6038EA2IM but with half-coupling only. To be used as spare. For complete specifications Bee page 81. H3B Department to direct purchase. 6038E-U79 ARP -480 - SEE ELECTRICAL SECTION 6038E-481 THRU -485 - SEE ELECTRICAL SECTION 6038E-U86 THRU -U95 - SEE ELECTRICAL SECTIOR 6038E-496 - 5T0RAULIC OIL (Rot shown on flow diagram) Ten-thousand (10,000) gallons, in transport truck lots, of Standard Oil Company's "Esstic 55" hydraulic oil. To be delivered at a date to be specified by the Operating Department. 6Q38E-497 - OIL PURIFIER Property Ro. Purifier - CA-63H-57 Pump - CA-6306-238 Motor - CA-6213-329 One (l) oil purifier to be used for purification of the oil in any of the five hydraulic oil systems. Purifier to be as follows: Manufacturer - Honan-Crane Corporation Service - Purification of Esstic 55 hydraulic oil at 115 F Model - 2036M8-AP equipped with insulation but without heaters. Pump - 5 gpm pump with kkO volt, 3 phase, 60 cycle motor for Class I Group D service to be furnished. Pump to be provided with relief valve and to be self-priming and suitable for a negative suction of 10 feet. Dolly - 28" x Uo" dolly with rubber tires and drawbar with handle shall be provided to mount purifier, pump and motor. Cartridges - Cranite filled. Ertra cartridges - Provide six (6) sets (of 8 cartridges each) to be used a6 spares. 6038E-498 ARP -498A - OIL FILTERS Property Ros. CA-6311-58 and 6311-59 repsectively (A) Two (2) oil filters for use in initial flushing and cleaning of oil lines before startup. These will be transferred to the Torrance California Plant when required there. 017264 22 LINE LIST Flow Diagram H3B-R10UU Note: All underground steel lines to have coating per Protective Covering Specifications. Number From to Size Material Handled Spec. H-U01 6038E-U01, 6038E-U01E, -U01A, HH-U31 H-U06 3", 6" Hydraulic Oil 200C# * Hydraulic Oil H-U02 6038E-li03, -U03A, HH-ii32 6038E-hD3E, H-U07 3", 6" Hydraulic Oil 2000# Hydraulic Oil H-U03 6038E-U05, 6038E-U05E, -U05A, HH--U33 H-Ii08 3", 6 Hydraulic Oil 2000# Hydraulic Oil H-iiOir 6038E-U07, 6038E-U07E, -U07A, HH-U3U H-U09 3% 6" Hydraulic '"11 2000# Hydraulic Oil H-U05 6038E-U09, -U09A, HK-ii35 6038E-U09E, H-U-0 3", 6" Hydraulic Oil 2000# Hydraulic Oil H-ii06 H-I4.OI H-U21, 11-hSl lA", 3" Hydraulic Oil 2000# & ^SirHydraulic Oil H-U07 H-U02 K-U22, H-1j52 lA", 3" Hydraulic Oil 2000# & 125# Hydraulic Oil H-l:08 K-U03 H-U23, H-153 lA'S 3" Hydraulic Oil 2000# & 125# Hydraulic Oil H-lj.09 H-hOii H-h2ii, HA5b lA", 3" Hydraulic Oil V 'Special supports and anchors as noted in introduction for this and all similar main oil lines. 2000# & 125# Hydraulic Oil 017265 23 LINE LIST - H3B-R10UU (C0NTD) Number From H-lilO H-U05 0 H-U25, H-U55 H-Iill 6038E-U02, 6038E-U02E, -U02A, HH-UUl H-ia6 H-U12 6038E-L0L, 6038E-UOUE, -U0I4A, HH-UU2 H-U17 6038E-U06, 6038E-U06E, -UO&, HH--Uli3 H-U18 H-UlU 6038E-U08, 6038E-U08E, -U08a., hh-UUU H-U19 H-U15 6038E-L10, 6038E-L10E, -UlQA., HH-UU5 H-U20 H-U16 K-101 H-U31, K-hSl H-U17 H-1j12 H-U32, H-US2 H-I418 H-U13 K-U33, K-153 H-HL9 H-UlU H-U3U, H-BU Size Material Handled SpecT 1/h", 3" Hydraulic Oil 200C# & 125,7 Hydraulic Oil 3", 6" Hydraulic Oil 200C# Hydraulic Oil 3", 6" Hydraulic Oil 2000# Hydraulic Oil 3", 6" Hydraulic Oil 2000# Hydraulic Oil 3", 6" Hydraulic Oil 2000# Hydraulic Oil ' 3", 6 Hydraulic Oil 200C# Hydraulic Oil 1/U", 3" Hydraulic Oil 2000# & 1250 Hydraulic Oil 1/U", 3" Hydraulic Oil 200C# & 1250 Hydraulic Oil 1/U", 3" Hydraulic Oil 2000# & 1250 Hydraulic Oil 1/U", 3" Hydraulic Oil 2000# & 125# Hydraulic Oil on*6 2k LINE LIST - H3B-H10W* (CONT'D) Number From "To-------------------- Size Material Handled Spec. H-U20 H-hl5 H-U35, H-U55 1/U", 3" Hydraulic Oil 2000# -& 125# Hydraulic Oil H-U21 6038E-U01E. H-I4Q6, HH-L&L 6038E-U01, -U01A, HH-hll 6", 3" Hydraulic Oil 200C# Hydraulic Oil K-U22 6038E-U03E. K-U07, HH-L52 6038E-U03, -U03A, HK-U12 6", 3" Hydraulic Oil 2000# Hydraulic Oil H-U23 6038E-LO5E. H-U08, HH-U53 6038E-UO5, -kO$k, HK-Iil3 6", 3" Hydraulic Oil 2000# Hydraulic Oil H-U2U 6038E-U07E. H-U09, HH-U5U 6038E-U07, -U07A, HH-LlL 6% 3" Hydraulic oil 200C# Hydraulic Oil H-U25 6038E-U09E. li-UlO, HH-L55 6038E-1409, -109A, HH-U15 6", 3" Hydraulic Oil 2000# Hydraulic Oil K-U26 NOT USED H-U27 NOT USED H-U28 NOT USED K-U29 NOT USED H-U30 NOT USED H-U31 6038E-U02E. HH-L51 6038E-U02, -U02A, HH-hll 6", 3" Hydraulic Oil 200C# Hydraulic Oil H-U32 6038E-liOiiE, H-L17, HH-uJ>2 6038E-U0U, -UOhA, HH-U12 6% 3'' Hydraulic Oil 2000# Hydraulic Oil H-h33 6038E-UO&, K-I1I8, HH-U53 6038E-ii06, -h061, HH-hl3 6% 3" Hydraulic Oil 200C# Hydraulic Oil 017267 25 LINE LEST - H3B-310U1* (CONT'D) Number From H-U3U 6038E-U08E. H-I119, hh-i524. To 6OU8E-UO8, -U08A, HH-Ulli Size 6", 3" H-Ij35 6038E-ia0E. H-I420, HH-U55 6038E-U0, -hlQA, HH-JT15 6", 3" H-U36 NOT USED H-U37 HOT USED H-U38 NOT USED H-U39 NOT USED H-UiO NOT USED H-ua 6038e-U H-UU2 ,6038E-Uiii H-iiii3 0383--UU6 h-im 6038E--UU8 H-U15 6038E-150 H-Uii6 NOT USED H-UU7 NOT USED K-Lii8 NOT USED E-hk9 NOT USED H-a50 NOT USED 6038E-U01, -UOIA, -1*02, -h02A 6038E-U03, -U03A, -UOU, -UOijA 6038E-U05, -Uo5a, -U06, -Uo& 6038E-U07, -h07A, -U08, -U08A 6038E-U09, -U09A, -UlO, -IOjQA 1-1/2", 2", 3" 1-1/2", 2, 3" 1-1/2", 2", 3" 1-1/2", 2", 3" 1-1/2", 2", 3" Material Handled Spec. Hydraulic Oil 2000# Hydraulic Oil Hydraulic Oil 200C# Hydraulic Oil Hydraulic Oil Hydraulic Oil Hydraulic Oil Hydraulic Oil Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 017268 26 LINE LIST - H3B-710UU (CONT'D) Number Fron H-U51 6038E-L01, -U02, H-U06, H-U16 To 6038E-U2U H-U52 6038E-U03, -kOk, H-U07, H-L17 6038E-U22A H-U53 6038E-U05, -hO 6, H-U08, H-U18 6038E-U23A H-U5U 6038E-U07, -Uo8, H-U09, H-U19 6038E-L2hA K-U55 6038E-U09, -hlO, K-UlO, K-U20 6038E-U2SA H-U56 MOT USED H-U57 HOT USED H-U58 HOT USED H-U59 NOT USED H-U60 NOT USED H-ua 6036E-U0LL, -U02A 6038e-L2Li H-U62 6038E-U03A, -UOiiA 6038E-U22A Size Material Handled Spec. 1/U", 3" Hydraulic Oil 1250 & 200C0 Hydraulic Oil 1/U", 3" Hydraulic Oil 125# & 2OCC0 Hydraulic Oil 1/U", 3" Hydraulic Oil lA", 3" Hydraulic Oil 1250 & 20000 Hydraulic Oil 125# & 2000# Hydraulic Oil 1/U", 3n Hydraulic Oil 1250 & 20000 Hydraulic Oil 1/U", 3" Hydraulic Oil 1/U", 3" Hydraulic Oil 125if & 20000 Hydraulic Oil 125," & 2000# Hydraulic Oil 017269 27 LINE LIST - H3B-ElOUi (CONT'D) Number From H-U63 6038E-U05A, -U06A To 6038E-U23A H-U61* 6038E-U07A, -I4D6A 6038E-U2U H-U65 6038E-U09A, -hlQA 6038E-U25A H-U66 NOT USED H-U67 NOT USED H-U68 NOT USED H-L69 NOT USED H-U70 NOT USED H-U71 6038E-U01E H-ii72 6038E-li03E H-L73 6038E-U05E H-U7U 6038E-L07E H-U75 6038E-U09E H-L76 NOT USED 6037E-301 H3B-R10L3 6037E-302, H3B-R10U3 6037E-303, H3B-R10B 6037E-30U, H3B-R10U3 6037E-305, H3B-H10U3 Size Material Handled Spec. l/U", 3" Hydraulic Oil 125# & 200C# Hydraulic Oil i/U, 3" Hydraulic Oil 125# & 200C# Hydraulic Oil l/U", 3" Hydraulic Oil 125# & 200C# Hydraulic Oil 6" Hydraulic Oil 2000# Hydraulic Oil 6" Hydraulic Oil 2000# Hydraulic Oil 6" Hydraulic Oil 2000# Hydra'Hi c Oil . 6" Hydraulic Oil 2000# Hydraulic Oil 6" Hydraulic Oil 2000# Hydraulic Oil 017270 2P LINE LIST - H3B-RlOUi (CCNT'D) Number From ------ To-------------------- Size Material Handled Spec. H-U77 NCT USED H-U78 NOT USED H-U79 NOT USED H-U80 NOT USED H-U81 6038E-U02E 6037E-30IA, H3B-R10ii3 6" Hydraulic Oil 2000# Hydraulic Oil H-L82 6038E-h0liE 6037E-302A, K3B-R10U3 6" Hydraulic Oil 200C# Hydraulic Oil H-U83 6O38E-I1O6E H-U8U 6038E-U08E H-U85 6038E-L10E 6037E-303A, H3B-R10U3 6037E-30ljA, H3B-HLOU3 6037E-305A, H3B-R10U3 6" 6" 6" Hydraulic Oil Hydraulic Oil Hydraulic Oil 2000# Hydraulic Oil 2000# Hydraulic Oil 2000# Hydraulic Oil H-U86 NOT USED H-U87 NOT USED H-U88 NOT USED H-U89 NOT USED H-U90 NOT USED H-U91 (Header) 6038E-U21A.'"' iA", Hydraulic Oil 3A", 2", 31. 125# Hydraulic Oil Lines to enter tank above oil level. o LINE LIST - H3B-R10U (CONT'D) 29 Revised 5/12/5^ Number H-492 From (Header) H-i+93 (Header) H-U9I+ (Header) H-495 (Header) To 6038E-U22A* 6038E-423A* 6038EA2UA* 6038EA25A* Size iA" . 3A", 2", 3" iA% 3A% 2", 3" iA", 3A\ 2% 3" lA", 3fr", 2", Material Handled Spec. Hydraulic Oil 125# Hydraulic Oil Hydraulic Oil 125# Hydraulic Oil Hydraulic Oil 125# Hydraulic Oil Hydraulic Oil 125# Hydraulic Oil H-^96 H-497 NOT USED NOT USED H-U98 H-L99 NOT USED NOT USED HH-kOl NOT USED AA-U02 WW-L03 6C&7A-922, H3B-R1051* NOT USED (Header) lA", 1", 3/8' Cu Air 96 HH-L04 HH-J+05 6038E-463 Charging Line 6038E-46U 6038E-U62 1-1/2" 2", 1-1/2" Hydraulic Oil Hydraulic Oil 12 125# Hydraulic Oil AA-k06 60U7A-922, H3B-R1054 AA-k07 and 6038E-I162 1" Air 96 AA-407 AA-406 6038E-k63 1" Air 96 PP-k>8 6043P-861 PP-k09, J+10 Lines to enter tank above oil level. 1/2", 1" Hydrogen Methane 55 (A) 017272 30 Revised 5/12/54 LIRE LIST - H3B-R1044 (C0NTD) Number Prom To Size Material Handled Spec. PP-409 PP-408 6038E-462 1" Hydrogen Methane 52 (A) PP-410 PP-408 6038E-463 1" Hydrogen Methane 52 (A) EE-411 H-421, -431 6038E-441 and H-491 1-1/4", 2", 3" Hydraulic Oil 125# 4 2000# Hydraulic Oil HH-412 H-422, -432 6038E-443 and H-492 1-1/4", 3" Hydraulic Oil 125# 4 2000# Hydraulic Oil HH-413 H-423, -433 6038E-445 and H-493 HH-414 H-424, -434 6038E-447 and H-494 HH-415 H-425, -435 6038E-449 and H-495 H5-416 NOT USED 1-1/4", 2% 3" 1-1/4% 2", 3" 1-1/4% 2", 3" Hydraulic Oil Hydraulic Oil fydraulic Oil 125# 4 2000# Hydraulic Oil 125# & 2000# Hydraulic Oil 125# & 2000# Hydraulic Oil HH-417 NOT USED HH-418 NOT USED HH-419 NOT USED HE-420 NOT USED HH-421 6038E-421M (Header) 3/4", 1" Hydraulic Oil HH-422 6038E-422M (Header) 3/4", 1" Hydraulic Oil Dotted portion on flow diagram piped by Vickers and assembled on 6038E-421A thru -425A. 300# Hydraulic Oil* 300# Hydraulic Oil* 017273 31 LINE- LIST - H3B-R10U1* (CONT'D) Number From ' HH-U23 6038E-U23M To-------------------(Header) HH-U2U 6038E-U214M (Header) HH-U25 6038E-U23M (Header) HH-U26 6038E-U02E-1 6038E-U02E HH-U27 6038E-UOI4E-I 6038E-U01aE HH-U28 6038E-U06E-1 6038E-U0& HH-U29 6O38E-I4D8E-I 6038E-U08E HH-U30 6O38E-I4IOE-I 6038E-I4IOE HH-U31 6038E-U21C H-U01 HH-U32 6038E-U22C K-U02 Size Material Handled Spec. 3A", 1" Hydraulic Oil 30C# * Hydraulic Oil 3A", 1" Hydraulic Oil 3000 * Hydraulic Oil 3A", 1" Hydraulic Oil 3000 * Hydraulic Oil 3A" Hydraulic Oil 3000 Hydraulic Oil 3A" Hydraulic Oil 30C# Hydraulic Oil 3A" Hydraulic Oil 3000 Hydraulic Oil 3A" Hydraulic Oil 3000 Hydraulic Oil 3/k" Hydraulic Oil 3000 Hydraulic Oil 2", 3n Hydraulic Oil 3OC0 & 20000 Hydraulic Oil 2", 3" Hydraulic Oil 300# & 20000 Hydraulic Oil ^Dotted portion on flow diagram piped by Vickers and assembled on 6038E-L2IA thru -b2$k. 01727^ 32 LINE HST - H3E-rJLDUi (CCUT`D) Number Frc-m HK-U33 6038E-U23C To-------------------H-U03 Size 2*', 3" HH-U3U 6038E-U2UC H-UOU 2", 3" HH-U35 6038E-U25C H-U05 2", 3" HH-U36 6038E-U02S-1 6038E-L02E 3/U" HK-U37 6038E-U0ijE-l 6038E-UOJ4E 3/U" HH-U38 6038E-U06E-1 6038E-UO& 3/U" HH-U39 6038E-U08E-1 6038E-U08E 3/U" HH-UUQ 6038E-Ii10E-1 6O38E-UIOE 3/U" HH-UUl 6038E-U21C H-Ull 2", 3" HH-UU2 6038E-U22C H-U12 2", 3" Material Handled Spec. Hydraulic Oil 300# & 2000# Hydraulic Oil Hydraulic Oil 30 Qr & 200C# Hydraulic Oil Hydraulic Oil 300# & 2000# Hydraulic Oil Hydraulic Oil 300# Hydraulic Oil Hydraulic Oil 300# Hydraulic Oil Hydraulic Oil 30C# Hydraulic Oil Hydraulic Oil 30C# Hydraulic Oil Hydraulic Oil 300# Hydraulic Oil Hydraulic Oil 300# & 2000# Ptydraulic Oil Hydraulic Oil 300# & 2000# Hydraulic Oil 017275 33 LINE LIST - H3B-R10UU (CONT'D) Number From HH-UU3 6038E-U23C To H-U13 HH-UUU 6038E-U21iC H-iilii HH-UU5 6038E-U25C H-Ul5 HH-UU6 6038E-L01E-1 6038E-U0IE HH-UU7 6038E-U03E-1 6038E-U03E HH-UU8 6038E-L05E-1 6038E-U05E HH-UU9 6038E-U07E-1 6038E-U07E HH-150 6038E-U09E-1 6038E-U09E HH-U51 6038E-U21A and HH-U71 H-U21, -U31 HH-U52 6038E-U22A and HK-U72 H-U22, -U32 Size 2% 3" 2", 3" 2", 3*' 3/U" 3/U" 3/U" 3/U" 3/U" 2", 3" 2", 3" Material Handled Spec. Hydraulic Oil 3C0# & 2000# Hydraulic Oil Hydraulic Oil 300# & 2000# Hydrauli* Oil Hydraulic Oil Hydraulic Oil 300# & 2000# Hydraulic Oil 300# Hydraulic Oil Hydraulic Oil 300# Hydraulic Oil Hydraulic Oil Hydraulic Oil 300# Hydraulic Oil 3m Hydraulic Oil Hydraulic Oil 300# Hydraulic Oil Hydraulic Oil 123#, 300# & 2000# Hydraulic Oil Hydraulic Oil 125#, 30c# & 200c# Hydraulic Oil 017276 LINE LIST - H3B-R10UU (CONTD) Number Erom To Size Material Handled Spec. HH-U53 6038E-U23A and HH-U73 H-U23, -U33 2", 3" Hydraulic Oil HH-U5U 6038E-U214A and HH-U7U H-ii2it, -U3L 2", 3" Hydraulic Oil HH-U55 6038E-L25A and HH-U?5 H-U25, -L35 2", 3" Hydraulic Oil 123#, 300# & 2000# Hydraulic Oil 123,#, 30C# & 2000# Hydraulic Oil 125#, 30C# & 2000# Hydraulic Oil HH-U56 6038E-U0IE-1 6038E-U01E 3/U" Hydraulic Oil 3m Hydraulic Oil hh-U57 6038E-L03E-1 6038E-U03E 3/U" Hydraulic Oil 300# Hydraulic Oil HH-U5B 6038E-U05E-1 6038E-U05E 3/U" Hydraulic Oil 300# Hydraulic Oil HH-U5? 6038E-U07E-1 6038E-U07E 3/U" Hydraulic Oil 300# Hydraulic Oil HH-U60 6038E-U09E-1 6036E-U09E 3/U'1 Hydraulic Oil 300# Hydraulic Oil HH-U61 Piped by Vickers and assembled on 6038E-U21A. HK-U62 Piped by Vickers and assembled on 6038E-U22A. HH-U63 Piped by Vickers and assembled on 6038E-U23A HH-U6U Piped by Vickers and assembled on 6038e-U21iA. HK-U65 Piped by Vickers and assembled on 6Q38e~U25A. 017277 35 LINE LIST - H35-RlOl4.il (CONT'D) Number From To " Size Material Handled Spec. HH-U66 Piped by Vickers and assembled on 6038E-U21A. HH-U67 Piped by Vickers and assembled on 6038e-Ii22A. HH-U68 Piped by Vickers and assembled on 6038E-U23A. HH-U69 Piped by Vickers and assembled on 6038E-U2UA. HH-U70 Piped by Vickers and assembled on 6038E-U25A. HH-U71 Piped by Vickers and assembled on 6038E-U21A . HH-U72 Piped by VickErs and assembled on 6038E-U22A. HH-U73 Piped by Vickers and assembled on 6038E-U23A. HH-U7U Piped by Vickers and assembled on 6038E-U21jA. HH-li75 Piped by Vickers and assembled on 6038E-U25A. HH-U76 NOT USED HH-U77 NOT USED HH-U78 NOT USED HH-U79 NOT USED HH-I48O NOT USED HH-U81 6038E-U01, -I4OIA HH-U82 6038E-JiC3, -U03A HK-U83 6038E-U05, -U05a HH-U8U 6038E-U07, -U07A 6038E-U01C 6038E-U03C 6038E-b05c 6038E-1407C 1/1" 1/U" 1/U" 1/U" Oil (Drain) Oil (Drain) Oil (Drain) Oil (Drain) 125# Hydraulic Oil 125T Hydraulic Oil 12# Hydraulic Oil 12# Hydraulic Oil 017278 36 LINE LIST - H3B-HL0Ui (GD'TT'D) Number From HH-U85 6038E-U09, -U09A To 6038E-a09C HH-U86 NOT USED HH-U87 NOT USED HH-U88 NOT USED HH-U89 NOT USED HH-U90 NOT USED HTI-U91 6038E-U62 Header HH-ii92 6038E-k63 HH-U93 NOT USED HH-U9U NOT USED HH-U95 NOT USED HH-U96 NOT USED HH-U97 NOT USED HH-U98 NOT USED HH-li99 NOT USED HHH-ItOl 6038E-U02, -U02A. HHH-U02 6038E-aoa, -UOlA HKH-U03 6038E-U06, -h06k Drain 6D38E-U02C 6038E-UOUC 60382-^060 Size iA" MS't-srx&X H&ncLLsd. Spec. Oil (Drain) 12# Hydraulic Oil 1-1/2" Hydraulic Oil 1-1/2" Water 12# Hydraulic Oil l/U" Oil (Drain) l/k Oil (Drain) 1/h" Oil (Drain) 12# Hydraulic Oil 12# Hydraulic Oil 12# Hydraulic Oil 017279 37 LINE LIST - H3B-R10UU (CONT'D) Number From ----- To--------------------- HHH-UOl; 603.8E-U08, -UoQti 6038E-U08C Size 1/ii" HHH-U05 6038E-U10, -U1QA 6038E-U10C l/U" HHH-U06 NOT USED Material Handled Spec. Oil (Drain) 125# Hydraulic Oil Oil (Drain) 125# Hydraulic Oil HHH-U07 NOT USED HHH-U08 NOT USED HHH-U09 NOT USED HHK-UlO NOT USED HHH-lOl Header Floor Drain 1/2", Oil (Drain) 3A", 1", 2" 1 HHH-102 Header Floor Drain 1/2", Oil (Drain) 3A", 1", 2" 1 HHH-i03 Header Floor Drain 1/2", Oil (Drain) 3A", 1", 2" 1 HHH-iali Header HHH-1415 Header Floor Drain Floor Drain 1/2", Oil (Drain) 3A", 1", 2" 1/2", Oil (Drain) 3A", 1", 2" 1 1 HTIH-U.6 NOT USED HHH-lil? NOT USED HHH-14.8 NOT USED HHH-U19 NOT USED HHH-U20 NOT USED 017280 38 LINE LIST - H3B-K10U1* (CCNT'D) Number From To Size Material Handled Spec. HHH-U21 NOT USED HHH-U22 HOT USED HHH-U23 NOT USED HHH-U2U NOT USED HHH-U25 NOT USED HKH-U26 NOT USED HHK-U27 NOT USED HHH-U28 NOT USED HHH-U29 NOT USED HHH-h30 NOT USED HHH-h31 Piped by Vickers and assembled on 6038E-U23A. KKH-U32 Piped by Vickers and assembled on 6038E-U22A. HHH-U33 Piped by Vickers and assembled on 6O30E-U23A. HHH-li3li Piped by Vickers and assembled on 6038E-U2U. HHH-U35 Piped by Vickers and assembled on 6038E-U25A. KHH-U36 NOT USED HHH-U37 NOT USED HHH-U38 NOT USED HKH-U39 HOT USED HEH-UiO NOT USED HHK-UU HK-U91 6038E-U21A 1-1/2" Hydraulic Oil 125# Hydraulic Oil HHH-Ui2 HH-lj.91 6038E-U22A 1-1/2" Hydraulic Oil 12$# Hydraulic Oil 017281 39 LINE LIST - H3B-R10Ui (CONT'D) Number From HHH-Ui3 HH-U91 To 6038E-U23A HHH-hUi HH-U91 6038E-li2LA HHH-UjS HH-U91 6038E-U25A HHH-U;6 NOT USED HHH-Ui7 NOT USED HHH-U48 NOT USED HHH-hlj.9 NOT USED HHH-hSO NOT USED HHH-U51 6038E-U2U 6038E-U31 HHH-U52 603 8E-U22A 6038E-U32 HHH-153 6038E-U23A. 6038E-U33 HHH-15U 6038E-U2ijA 6038E-U3U HKH-U55 6038E-U25A 6038e-1*35 HHH-U56 NOT USED HHH-U57 NOT USED hhh-158 NOT USED e CM Size 1-1/2" 1-1/2" 1-1/2" Material Handled Spec. Hydraulic Oil 125# Hydraulic Oil Hydraulic Oil 125# Hydraulic Oil Hydraulic Oil 125# Hydraulic Oil 2", 3" Hydraulic Oil 2", 3" Hydraulic Oil 2", 3" Hydraulic Oil Hydraulic Oil 2", 3" Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 017282 iiO LINE LIST - H3B-H10U* (CONT'D) Number From HHH-U59 NOT USED HHH-U60 NOT USED HHH-U61 6038E-hi|l To 6038E-U2IA HHH-U62 6O38E-I4I43 6038E-U22A HHH-L63 6038E-LLS 6038E-U23A HHH-U6U 6038E-UU7 6038E-U21jA HHH-U65 6038E-UL9 6038E-U25A HHH-U66 NOT USED HHK-U67 NOT USED HHH-U68 NOT USED HHH-U69 NOT USED HHH-U70 NOT USED HHH-U71 NOT USED HHH-U72 NOT USED HHH-U73 NOT USED HHK-U7U NOT USED HHK-U75 NOT USED HHH-L76 NOT USED HHH-U77 NOT USED Size Material Handled Spec. 2, 3" Hydraulic Oil 2", 3" Hydraulic Oil 2", 3" Hydraulic Oil 2", 3" Hydraulic Oil 2", 3" Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 017283 Ill LINE LIST - H3B-R10Ui (CONT'D) Number From HHH-U78 NOT USED HHH-U79 NOT USED HHH-U80 NOT USED HHH-U81 6038E-U31 To 6038E-U1* HHH-U82 6038s-h32 6038E-IM HHK-U83 6038E-1433 6038E-U16 HHH-U8U 6038E-U3U 6038E-UU8 HHK-U85 6038E-U35 6038E-hS0 HHH-U86 NOT USED HHH-U87 NOT USED HHH-U88 NOT USED HHH-U89 NOT USED HHH-U90 NOT USED HHH-U91 NOT USED HHH-U92 NOT USED HHH-U93 NOT USED HHE-U9U NOT USED HHH-U95 NOT USED HHK-U96 NOT USED Size Material Handled Spec. 1-1/2", 2", 3" Hydraulic Oil 1-1/2", 2", 3" Hydraulic Oil 1-1/2", 2", 3" Hydraulic Oil 1-1/2", 2", 3" Hydraulic Oil 1-1/2", 2", 3" Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 017284 U2 LINE LIST - H3B-KL0Ul (CONTD) Number tf'rom HHH-li97 HHH-U98 NOT USED NOT USED HHH-U99 NOT USED To WWWW-ljQl 60U7W-902, H3B-R1Q5U WWWW-U02 60h7W-902 H3B-R105U wwww-U03 60U7W-902, H3B-R105U wwww-LOU 60U7W-902, H3B-R105U WJWW-UOJ? 60U7U-902, H3B-R1051i IMJU-U06 NOT USED WWWW-U07 NOT USED WWWW-14D8 NOT USED WWWW-U09 NOT USED WWWW-hlD NOT USED T-JlJlJW-Ull 6038E-lijl, -UU2 UJNW-U12 6038E-UB, -m '.MM403 6038E-U5, -hk6 ww.ju-iai* 6038E-Uli7, -U18 WWHi-MjlS 6038E-Iili9, -U50 6038E-Uil, -hh2 6038E-143, -kith 6038E-U5, 6038E-I4i7, -UU8 6038E-UU9, -150 60U7W-903, H3B-R105U 60U7W-903, H3B-H105U 601*71.-903, H3B-R1051* 60U7W-903, H3B-R105U 60l*7W-903, H3B-R105U Size Material Handled Spec. 2", 3" 2", 3" 2", 3" 2", 3" 2", 3" Cooling Cycle Water Cooling Cycle Water Cooling Cycle Water Cooling Cycle Water Cooling Cycle Water 1, 21 1, 21 1, 21 1, 21 1, 21 2", 3" 2", 3" 2", 3" 2", 3" 2", 3" Cooling Cycle Water Cooling Cycle Water Cooling Cycle Water Cooling Cycle Water Cooling Cycle Water 1, 21 1, 21 1, 21 1, 21 1, 21 017285 LEE LIST - H3B-RlOJii (CONT'D) Number From VMJW-ia6 NOT USED WVJUVJ-Lil7 NOT USED wjwi-MOS NOT USED WJMil9 NOT USED vjimw-U20 NOT USED To--------------- HHHK-U21 6038E-U21A Drain HHHH-U22 6038E-L22A Drain HHHH-U23 6038E-lj23A Drain HHHH-U2L 6038E-U2I4A Drain HHHH-U25 6038E-U25A Drain Size Material Handled Spec. 1-1/2" Oil 1-1/2" Oil 1-1/2" Oil 1-1/2" Oil 1-1/2" Oil 125# Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 125# Hydraulic Oil 017286 Mi VALVE LIST Flour Diagrc. H3B-R1Q44 Number 4001 4002 4003 4004 4005 4006 4007 4003 4009 4010 4011 4012 4013 4014 4015 4016 4017 401S 4019 4020 4021 4022 Location 6C38E-401A 603SE-403A 6038E-405A 6038E-407A 6033E-409A H-406 H-4C7 H-408 H-409 H-410 6038E-402A 6038S-404A 6038S-406A 6038E-408A 60383-41CA H-416 K-417 H-418 H-419 H-420 6C38E-401 6038B-403 Service Check Check Check Check Check Check Check Check Check Check Check Check Check Check Check Check Check Check Check Check Check Check Size 1/2" 1/2" 1/2" 1/2" 1/2" 1/4" 1/4" 1/4" 1/4" 1/4" 1/2" 1/2" 1/2" 1/2" 1/2" 1/4" 1/4" 1/4" 1/4" 1/4" 1/2" 1/2" C&CCC No. 201 201 201 201 201 Vickers C2-300* Vickers C2-800* Vickers C2-800* Vickers C2-800* Vickers C2-800* 201 201 201 201 201 Vickers C2-800* Vickers C2-800* Vickers C2-800* Vickers C2-800* Vickers C2-800* 201 201 017287 VALVE LIST - H3B-R1044 (CONT'D) Number Location Service Size C&CCC No. 4024. 60382-407 Check 1/2" 201 4C25 60332-409 Check 1/2" 201 4026 K-406 Check 1/4" Vickers C2-800* 4027 K-407 Check 1/4" Vickers C2-800* 4028 H-408 Check 1/4" Vickers C2-800* 4029 H-409 Check 1/4" Vickers C2-800# 4030 H--410 Check 1/4" Vickers C2-800# 4031 60382-402 Check 1/2" 201 4C32 60382-404 Check 1/2" 201 4033 6038E-406 Check 1/2" 201 4034 6C38E-408 Check 1/2" 201 4C35 4036 6033E-410 K-416 Check Check 1/2" 1/4" 201 Vickers C2-8C0# 4037 4038 4039 H-417 H-418 K-a9 Check Check Check 1/4" 1/4" 1/4" Vickers C2-800* Vickers C2-800# Vickers C2-800# 4040 H-420 Check 1/4" Vickers 02-800# 4041 6C3S2-401A Shutoff 3/4" 1 4042 6038E-403A Shutoff 3/4" 1 4043 4044 603S2-405A 603S2-4C7A Shutoff Shutoff 3/4" 3/4" 1 1 017288 4045 603 3^-4+09A Shutoff 3/4" 1 4046 H-406 Relief 1/4" Vickers 0-175-C-10 + H-4C7 Relief 1/4" Vickers C-175-C-10 + * Reference lie. (21) on H3B-B1359-1, purchased -with 603SE-421 etc. + Reference No. (20) on H3B-31359-1, purchased with 60382-421 etc. h.6 VALVE LIST - H33-R10U (CONT'D) Number Location Service Size C&CCC No. 4048 K-408 Relief 1/4" Vickers C-175-C-10 + 4049 H-409 Relief 1/4" Vickers C-175-C-10 + 4050 E-410 Relief 1/4" Vickers C-175-C-10 + 4051 6033E-402A Shutoff 3/4" 1 4052 6C38E-404A Shutoff 3/4" 1 4053 6038E-406A Shutoff 3/4" 1 4054 6C3SE-408A Shutoff 3/4" 1 4055 6C38E-410A Shutoff 3/4" 1 4056 K-416 Relief 1/4" Vickers C-175-C-10 + 4057 H-417 Relief 1/4" Vickers C-175-C-10 4055 H-41S Relief 1/4" Vickers C-175- -10 + 4C59 4060 11-418 11-420 Relief Relief 1/4" 1/4" Vickers C-175-C-10 + Vickers C-175-0-10 + 4061 6038E-401 Shutoff 3/4" 1 4062 603SE-403 Shutoff 3/4" 1 4063 6C33E-405 Shutoff 3/4" 1 4064 4065 603SE-407 6038E-409 Shutoff Shutoff 3/4" 3/4" 1 017289 4066 H-4C1 Pressure gauge 1/4" Vickers #134641* 4067 K-402 Pressure gauge 1/4" Vickers #134641* 4065 H-403 Pressure gauge 1/4" Vickers #134641* 4069 H-404 Pressure gauge 1/4" Vickers #134641* 4070 H-405 Pressure gauge 1/4" Vickers #134641* 4071 603SE-402 Shutoff 3/4" 1 + Reference No. (2C) on K3B-B1359-1, purchased with 6038E-421 etc. * Reference Nc. (18) on H3B-31359-1, purchased with 6038E-A21 etc. L? VALVE LIST - H3B-H1044 (CONT'D) Number Location Service Size CfitCCC No. 4072 6033E-404 Shutoff 3/4" 1 4073 60382-406 Shutoff 3/4" 1 4074 6033E-408 Shutoff 3/4" 1 4075 6038E-410 Shut off 3/4" 1 4076 K-411 Pressure Gauge 1/4" Vickers #134641* 4077 M--412 Pressure Gauge 1/4" Vickers #134641* 4078 H-413 Pressure Gauge 1/4" Vickers #134641* 4079 H-414 Pressure Gauge l/4" Vickers 4134641* 4C3C H-415 Pressure Gauge 1/4" Vickers #134641* 4C31 H-441 Control 1-1/2" 1 4062 H-442 Control 1-1/2" 1 4CS3 4034 4035 4086 4087 4088 4039 K-443 H-444 H-445 ivU'I1 ;&t UESB Control Control Control s92/rePt* ^//UTQPP JSMT6PF //uTt>PF 1-1/2" 1-1/2" 1-1/2" *" 1 1 1X r / i i 4091 K-441 Control 1-1/2" i 4092 H-442 Control 1-1/2" i 4093 4094 4095 H-443 H--4-4-^ K-445 Control Control Control 1-1/2" 1-1/2" 1-1/2" -L 1 i * Refers nee No. (18) on H3E-B1359-1, purchased v.ith 6G38E-421 etc. 017290 VALVE LIST - H3B-R1044 (CONT'D) Kunber 4096 4097 4098 4C99 4100 4101 4102 4103 4104 4105 4106 4107 4106 4109 4110 4111 4112 4113 4114 4115 4116 4117 4118 4119 Location NOT USED H-441 H-442 H-443 H-444 H-445 msa NOT1 UDb&NOT USED NOT USED NOT USED H-441 K-442 H-443 K-444 H-445 NOT USED NOT USED NOT USED NOT USED Service 5//UT0FF S/ZuraFF SJteZdFF Control Control Control Control Control Control Control Control Control Control Size J#/" */T ay Ci-CCC No. / / ) 1 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" -n 1 1 1 1 1 / / 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1 1 1 -Jtm I 017291 VALVE LIST - K3B-R2044 (COIN'D) Nunber Location 4120 NOT USED 4121 H-461 4122 K-462 4123 H-463 4124 H-464 4125 4126 H-465 NOT USED 4127 4128 4129 1*130 4131 NOT USED NOT USED NOT USED NOT USED H-461 4132 H-462 4133 4134 H-463 H-464 4135 H-465 4136 NOT USED 4137 NOT USED 4138 NOT USED 4139 NOT USED 4140 NOT USED 4141 H-461 4142 H-462 4143 H-463 Service Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Check Check Check h9 Size C&CCC No. 1/4" 1/4" 1/4" 1/4" 1/4" Vogt 1871 Vogt 1871 Vogt 1871 Vogt 1871 Vogt 1871 1/4" 1/4" 1/4" 1/4" 1/4" Vogt 1871 Vogt 1871 Vogt 1871 Vogt 1871 Vogt 1871 3" Powell 1561 3" Powell 1561 3" Powell 1561 017292 VALVE LIST - H3I-R1044 (CCNT'D) Nunber Location 4144 11-464 4145 4146 K-465 NOT USED 4147 NOT USED 4148 NOT USED 4149 NOT USED 4150 NOT USED 4151 H-451 4152 H-452 4153 H-453 4154 K-454 4155 4156 H-455 NOT USED 4157 NOT USED 4158 .. NOT USED 4159 NOT USED 4160 NOT USED 4161 H-451 4162 H-452 4163 H-453 4164 H-454 4165 H-455 4166 4167 NOT USED 'NOT USED Service Check Check Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff 50 Size 3" 3" CccCCJ No. Pot,ell 1561 Powell 1561 1/4" 1/4" 1/4" 1/4" 1/4" Vogt 1871 Vogt 1871 Vogt 1871 Vogt 1871 Vogt 1871 1/4" 1/4" 1/4" 1/4" 1/4" Vogt 1871 Vogt 1871 Vogt 1871 Vogt 1871 Vogt 1871 017293 51 VALVE LIST - H3B-R1044 (CONT'D) Number Location Service Size C&CCC No. 4168 NOT USED 4169 4170 NOT USED NOT USED 4171 H-451 Check 3" Powell 1561 4172 4173 4174 H-452 H-453 H-454 Check Check Check 3" Powell 1561 3" Powell 1561 3" Powell 1561 4175 4176 H-455 NOT USED Check 3" Powell 1561 4177 NOT USED 4178 NOT USED 4179 4180 NOT USED NOT USED 4181 H-406 Relief 3" Vickers Mo. CF-24-F-10* 4182 H-407 Relief 3" Vickers No. CF-24-F-10* 4183 H-408 Relief 3" Vickers No. CF-24-F-10-:;- 4184 H-409 Relief 3" Vickers No. CF-24-F-10* 4185 H-410 Relief 3" Vickers Ho. CF-24-F-10* 4186 H-406 Relief 3" Vickers No. CF-24-F-10*- 4187 H-407 Relief 3" Vickers No, CF-24-F-10* 4188 H-408 Relief 3" Vickers No. CF-24-F-1CH- 4189 H-409 Relief 3" Vickers No. CF-24-F-10* 4190 H-410 Relief 3" Vickers No. CF-24-F-lOv- 4191 H-416 Relief 3" Vickers No. CF-24-F-10* Reference* No. (3) on H3B-B1359-1, purchased with 6038E-421, etc. 0*17294 52 VALVE LIST - H3E-R1044 (CONT'D) Number Location Servi Size C&CCC No. 4192 K-417 Relief 3" Vickers No. CF-24-F-1D* 4193 4194 4195 H-41S H-419 H-420 Relief Relief Relief 3" Vickers No. CF-24-F-10* 3" Vickers No. CF-24-F-10* 3" Vickers No. CF-24-F-10* 4196 4197 H-426 H-417 Relief Relief 3" Vickers No. CF-24-F-10* on Vickers No. CF-24-F-lOtt 4198 H-418 Relief 3" Vickers No. CF-24-F-lO::- 4199 K-419 Relief 3" Vickers No. CF-24-F-10* 4200 H-420 Relief 3" Vickers No. CF-24-F-10* 4201 HE-461 Relief 2" Vickers No. CF-16-B-10+ 4202 HH-462 Relief 2" Vickers No. CF-16-B-10+ 4203 HH-463 Relief 2" Vickers No. CF-16-B-1C+ 4204 HH-464 Relief 2" Vickers No. CF-16-3-10+ 4205 HE-465 Relief 2" Vickers No, CF--16--D--10+ 4206 NOT USED 4207 NOT USED 4208 4209 NOT USED NOT USED 017295 4210 NOT USED 4211 HH-421 Relief 3/4" Vickers No. CT-06-E-1O-::-: 4212 HK-422 Relief 3/4" Vickers No. CT-06-D-10-:h 4213 H: 1-423 Relief 3/4" Vickers Nc. CT-C6-B-10-::-: 4214 HH-424 Relief 3/4" Vickers No. CT-06-B-1D-5H 4215 HH-425 Relief 3/4" Vickers No# Cx-06-B-IO-JK * Reference No. (3) cn H33-B1359-1, purchased vdth 6038E-ii21, etc. + Reference lie. (8) on K3B-B1359-1, purchased ?.d.th 60383-1*21, etc. Reference No. (10) cn H3B-31359-1, purchased ivith 6038E-4ZL, etc. 53 VALVE LIST - H32-R1044 (COIIT'D) lumber Localion Service Size C&CCC No. 4216 HOT USED 4217 4218 NOT USED NOT USED 4219 4220 NOT USED NOT USED 4221 4222 4223 4224 4225 4226 4227 4228 6037E-3C1 6037E-302 6037E-303 60372-304 6037E-305 NOT USED NOT USED NOT USED Pressure Gauge Pressure Gauge Pressure Gauge Pressure Gauge Pressure Gauge 1/4" 1/4" 1/4" 1/4" 1/4" Vickers No. 134641-::Vickers No. 134641-* Vickers No. 134641* Vickers No. 134641* Vickers No. 134642 4229 4230 HOT USED NOT USED 4231 4232 4233 4234 4235 4236 6037E-301A 6037E-302A 6037E-303A 6037E-304A 6037E-305A NOT USED Pressure Gauge Pressure Gauge Pressure Gauge Pressure Gauge Pressure Gauge 1/4" 1/4" 1/4" 1/4" 1/4" Vickers No. 134641-::Vickers No. 134641-::Vickers No. 134641* Vickers No. 134641* Vickers No. 134641* 4237 NOT USED 4238 4239 NOT USED NOT USED 017296 * Reference So. (18) on H3B-31359-1, purchased v,ath 6038E-1*21, etc BL VALVE LIST - H33-R1044 (COST'D) Number 4240 4241 4242 4243 4244 4245 4246 4247 4243 4249 4250 4251 4252 4253 4254 4255 4256 4257 4253 4259 4260 4261 Location NOT USED HH-411 HH-412 HH-413 HH-414 HH-415 HOT USED NOT USED NOT USED NOT USED NOT USED HH-411 HH-412 HH-413 HH-414 HH-415 NOT USED NOT USED NOT USED NOT USED NOT USED HH-42L Service Size C&CCC No. Flow Control Flow Control Flow Control Flow Control Flow Control 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" Vickers No. FGY-10-50-10+ Vickers No. FGY-10-50-10+ Vickers No. FGY-10-50-10+ Vickers No. FGY-10-50-10+ Vickers No. FGY-10-50-10+ FI or.' Control Flow Control Flow Control Flow Control Flow Control 1-1/4" 1-1/4" 1-1/4" 1-1/4" 1-1/4" Vickers No. FGY-10-50-10+ Vickers No. FGY-10-50-10+ Vickers No. FGY-10-50-10 Vickers No. FGY-10-50-1O Vickers No. FGY-10-50-1O Pressure Gauge 1/4" Vickers No. 8071* * Reference No. (7) on H3B-B1355-1, purchased with 6038E-ii21, etc. * Reference Mo. (19) on H33-B1359-1 purchased with o038E-Ii21, etc. 017297 55 VALVE LIST - H3B-R10UL (CONT'D) Number 1262 ii.263 1261 h265 1266 1267 1268 1269 U2 70 1271 1272 1273 U27U 1275 U276 1277 1276 1279 1280 1281 Location . HH-122 HH-123 : HH-121 HH-125 NOT USED NOT USED NOT USED NOT USED NOT USED HH-161 HH-162 HH-163 HH-161 HH-165 NOT USED NOT USED NOT USED NOT USED NOT USED HH-131 Service Size Pressure Gauge lA" Pressure Gauge lA" Pressure Gauge lA" Pressure Gauge lA" Pressure Gauge iA" Pressure Gauge iA" Pressure Gauge iA" Pressure Gauge iA" Pressure Gauge iA" Check 2" C&CCC No. Vickers No. 8071* Vickers No. 8071* Vickers No. 8071* Vickers No. 8071* Vickers No. 8071* Vickers No. 8071* Vickers No. 8071* Vickers No. 8071* Vickers No. 8071* Vickers No. DF10P1-16-5-20 + * Reference No. (19) on H3B-B1359-1, purchased with 6038E-121, etc. + Reference No. (1) on H33-B1359-1, purchased with 603BE--121, etc. must be installed with ports of valve in horizontal plane. 017298 VALVE :LIST - H3B--RlOiiii (CONT'D) 56 Number Location Service Size C&CCC No. ii282 HH-U32 Check 2" Vickers No. DF10P1-16-5-20 + U283 HH-U33 Cheok 2" Vickers No. DF10P1-16-5-20 + U28U HH-U3U Check 2 Vickers No. DF10P1--16-5-20 + U283 4286 HK-U35 NOT USED Check 2" Vickers No. DF10P1-16-5-20 + 4287 4288 NOT USED NOT USED 4239 NOT USED 4290 NOT USED 4291 4292 4293 4294 4295 4296 4297 KH-441 HH-442 HH-443 HH-444 HK-445 NOT USED NOT USED Check Check Check Check Check 2" Vickers No. + DF10P1-16-5-20 2" Vickers No, + DF10P1-16-5-20 2" Vickers No. + DF10P1-16-5-20 2" Vickers No. + DF10P-16-5-20 2 Vickers No. + DF1CP1-16-5-20 4298 NOT USED 4299 NOT USED 4300 NOT USED 4301 HH-451 Check 2" Vickers No. DF10P1-16-5-20 + + Reference No. (1) on H3B-31359-1, purchased vith 60382-421, etc. must be installed vith ports of valve in horizontal plane. 017299 57 VALVE LIST - E3E-R1044 (CONT'D) Number Location Service Size CscCCC No. 4302 HH-452 Check 2" Vickers No. DF10P1-16-5-20 + 4303 HH-453 Check 2" Vickers No. DF10P1-16-5-20 + 4304 HH-454 Check 2" Vickers No. DF10P1-16-5-20 + 4305 HH-455 Check 2" Vickers No. DF1CP1-16-5-20 + 4306 NOT USED 4307 NOT USED 43CS NOT USED 4309 4310 NOT USED NOT USED 4311 KE-451 Check 2" Vickers No. DF10P1-16-5-20 + 4312 HH-452 Check 2" Vickers No. DF10P1-16-5-20 + 4313 HH-453 Check 2" Vickers No. DF10 Pl-16-5-20 + 4314 HK-454 Check 2" Vickers No. DF10P1-16-5-20 + 4315 4316 HH-455 NOT USED Check 2" Vickers No. DF10P1-16-5-20 + 4317 NOT USED + Reference IJc. (1) on H3B-31359-1, purchased rath 6C38E-421,etc. must be installed rith ports of valve in horizontal plane. 017300 VALVE LIST - K3B-R1044 (CONT'D) Number 4318 4319 4320 4321 4322 4323 4324 4325 4326 4327 4323 4329 4330 4331 4332 4333 4334 4335 4336 4337 4338 4339 Location NOT USED NOT USED NOT USED HH-451 KrI-452 HH-453 HH-454 HU-455 NOT USED NOT USED NOT USED NOT USED NOT USED HH-451 KK-452 HH-453 HH-454 HH-455 NOT USED NOT USED NOT USED NOT USED Service Check Check Check Check Check Shutoff Shutoff Shutoff Shutoff Shutoff 58 Size C&wCC Nc, 2" Lunk 624 2" Lunk 624 on A. Lunk 624 2" Lunk 624 2" Lunk 624 2" Nordstrom 1924 2" Nordstrom 1924 2" Nordstrom 1924 Nordstrom 1924 2" Nordstrom 1924 017301 59 VALVE LIST - H33-R1G44 (COKT'D) Lumper 4340 4J4i" tm *> Location NOT USED lH1-4j'-T Service 'Siiutorr ctVm+nff 4343- HTT-473 -4345 - .stmturr-Shntofr-` 4346 HH-471 4347 4348 KK-472 KH-473 4349 Mi-474 4350 HH-475 -4332- -4-353 -4354~ 43554356 ' S-491 H-492- H-493- H-494 Snare + Relief Valve Relief Valve Relief Valve Relief Valve Relief Valve cu,,* ~.rr* Ehuteff amiufr~ Shutoff" Shutof-rRelief Valve Size C&CCC No. Su" Supplied by ViokeP9-\ with 6030E*421A, ctc.\ -2**- -Supplied b.y VlUkdX'iT with tOjdL-^-U, eti; l 2~ "~ 2P-- -Supplied by Vickeii v:iLL 603SE-421A, etc. / Supplied by victors-- / gi&h 60355 421A, etc. / / -2**-- Supplied by Viikuto / -with 601 CE~ 4S1Aj otai 1-1/1*" Vickers No. CT-10-3-10*- 1-1/4" Vickers No. CT-10-3-10* 1-l/ii" 1-1/1" 1-1/1" Vickers No. CT-10-3-10* Vickers No. CT-I0-B-1Q* Vickers No. CT-1G-B-1G*- -3"- dwi'dj ti uui -3*- 'NeidsUum 1925 Nurds U'Ui:rt925 X^)*/^ 3**5" l-l/ii" .NordPt-roia 19S5J Jtopdstrum Vickers Mo. CT-1C-3-10-!:- * Reference I:o. (22) on K33-B1359-1, p'+ Not shorn on flor diagram.. ed T.ith 6038E-421, etc. 077302 60 VALVE LIST - K33-R1044 (CONT'D) Number 4357 4358 4359 4360 4361 4362 4363 4364 4365 4366 4367 4368 4369 4370 4371 4372 4373 4374 4375 4376 4377 4378 4379 4380 Location Service Size COCCC No. NOT USED NOT USED NOT USED NOT USED SHUTO FF Cutoff SH^toff /" /" /" SH<JTo FF /" -IlUx UoELI Itiulii/M-HrOl iddidid t tiU'i UOiil/idvJyu idM.6 2-> -Ner-ussu-- iduJioU>- 2^OT=USE& 2/u'idV} ' VCd mil uezd 5H^toff Stf&croFf //* TOFF S/fu.TaF/* *F/u FoF/F S/*dTo FF ToF^ J>/SicT /" ... * " >A" - - /" //" 2 r NUx USLJ _ _ ^JiJjdv) 6~5 -scr-^usfi&r. _ Wfff "HSgD MdidtfJ NOT USED j".. y -a: NOT USED.___ NOT USED NOT USED NOT USED 017303 VALVE LIST - H3B-R1044 (CONT'D) Humber 4381 4382 4363 4384 4385 4386 4387 4388 4389 4390 4391 4392 4393 4394 4395 4396 4397 4398 4399 4400 4L01 4402 4403 kkOk Location PP-408 PP-408 PP-408 PP-408 PP-408 PP-408 PP-4o8 PP-408 PP-409 PP-410 PP-410 HH-492 HH-492 HH-492 HOT USED NOT USED NOT USED NOT USED NOT USED NOT USED AA-402 AA-402 AA-402 AA-402 Service Shutoff Shutoff Instrument Pressure Gauge Vent Shutoff Shutoff Shutoff Pressure Gauge Pressure Gauge Vent Shutoff Check Shutoff Shutoff Shutoff Shutoff Shutoff Size 1/2" 1/2" 1/2" 1/2" 1/2" 1" 1" 1" 1/2" 1/2" 1" 1-1/2" 1-1/2" 1-1/2" 1/4" 1/4" 1/4" 1/4" 61 Revised 5/12/54 C&CCC No. 55 55 115 115 55 55 55 55 196 196 1 1 213 24 (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) 1 1 1 1 017304 VALVE LIST - H33-R10Ui (CONT'D) Number hko$ bii06 4407 4408 4409 4410 4411 4412 4413 4415 4416 4417 441S 4419 4420 4421 4422 4423 4424 4425 4426 4427 4428 Location AA-U02 NOT USED NOT USED NOT USED NOT USED NOT USED A4-402 AA-402 A-i-402 AA-402 iu',-402 NOT USED NOT USED NOT USED NOT USED NOT USED HHH-441 HHN-442 me:-443 IESi-444 HUE-445 NOT USED NOT USED NOT USED Service Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Size 1/li" C&CCC No* 1 1/1;" 1/4" 1/4" 1/4" 1/4" -L 1 1 l 1 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" l 1 1 1 1 017305 VALVE LIST - K3B-H1G44 (COHT'D) Number 4429 4430 4431 4432 4433 4434 4435 4436 4437 4438 4439 4440 4441 4442 4443 4445 4446 4447 444S 4449 4450 4451 4452 Location NOT -USED NOT USED HHH-461 KHK-462 HKK-463 HE-:-464 HKH-465 HOT USED HOT USED HOT USED HOT USED HOT USED '.'.r".7.--401 TTTTr-402 T7WW7T-403 TJVWT7-4C4 VJTTvTTT--405 HOT USED HOT USED NOT USED HOT USED HOT USED 6038E-iuilA 6038E-Ui3A Service Check Check Check Check Check Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff 63 Size C&CCC No. 2" 201 2" 201 2" 201 2" 201 2" 201 3" cr 3" 5 3" ? 3" 3 Oil 5 . 1-1/4" 1-1/4" l 1 017306 VALVE LIST - H3B-R1G44 (CONT'D) Number 4453 4454 4455 a 56 4457 4458 4459 4460 4461 Location 6038E-liU5A 6038E-Uii7A 6038E-Lii9A NOT USED NOT USED NOT USED NOT USED NOT USED v.t.v.t;-401 Service Shutoff Shutcff Shutoff Control 4462 T7W-4C2 Control 4463 777777-403 Control 4464 V,r;.T.T;-404 Control 4465 4466 4467 4463 *44*0 V* 4471 tat;1 .-405 NOT USED NOT USED NOT' USED NOT USED 7.7T~ -401 Control Control 4472 7.770-402 Control 4473 T772T7-4C3 Control Size 1-1/4" 1-1/4" 1-1/4" C&CCC No. 1 1 1 2" Powell Fig. 957 or equal 2" Poire11 Fig. 957 or equal 2" Poirell Fig. 357 or equal 2" Powell Fig. 957 or equal 2" Poire11 Fig. 957 or equal 2" Powell Fig. 957 or equal 2" Powell Fig. ?57 or equal 2" Powell Fig. 957 or equal 017307 VALVE LIST - H33-R1C44 (CONT'D) Number 4474 Location 7MJY7-4C4 Service Control 4475 '.7TTA7-405 Control 4476 4477 4478 4479 4430 4431 4482 4483 4484 4485 4486 4437 4438 4489 4490 4491 4492 4493 4494 4495 NOT USED NOT USED NOT USED NOT USED NOT USED HHH-481 HHH-4S2 HHH-483 HHH-484 HHK-485 NOT USED ' NOT USED NOT USED NOT USED NOT USED HUE-481 HHK-4S2 HHH-483 HHH-484 HHH-485 Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff 65 Size 2" 2" Cl-CCC No. Powell Fig. 957 or equal Powell Fig. 957 or equal 1/2" 1/2" 1/2" 1/2" 1/2" 1 1 1 1 1 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1 1 ]_ 1 1 017308 VALVE LIST - H3B-R1044 (COST'D) Number Location Service 4496 HOT USED 4497 NOT USED 4498 NOT USED 4499 NOT USED 450C NOT USED 4501 HHH-411 Shutoff 4502 H2I-412 Shutoff 4503 4504 NHH-413 HIiH-414 Shutoff Shutoff 4505 4506 4507 4503 4509 4510 he:-415 KMK-4I1 HKK-412 KHK-413 HSH-414 HHH-415 Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff 4511 HHK-4S1 Check 4512 HHH-482 Check 4513 HHH-4S3 Check 4514 HHH--484 Check 4515 HHK-4S5 Check 4516 :-:-::-4ii Shutoff 4517 ee:-412 Shutoff 4518 Knn-413 Shutoff 4519 rlEI-414 Shutoff 66 Size C&CCC No. 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 2" 2" 2" 2" 2" 3/4" 3/4" 3/4" 3/4" 1 1 1 1 1 1 x 1 1 1 201 201 201 201 201 1 1 1 1 017309 VALVE LIST - H3B-R1044 (CONT'D) Number 4520 4521 4522 4523 4524 4525 4526 4527 4528 4529 4530 4531 4532 4533 4534 4535 4536 4537 4538 4539 4540 4541 4542 4543 Location HKH-415 ,~7.'T:-411 : 7H7OT-412 77-413 TJUT7U-414 TT.T.T.-415 HOT USED NOT USED NOT USED NOT USED EOT USED IEEI-451 HZI-452 KHK-453 HUE-454 HHK-455 NOT USED NOT USED NOT USED NOT USED NOT USED HKHE-421 HIITH-422 KHHH-423 Service Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutof: Shutcff Shutoff Shutoff r-T H1 67 Size 3/4" 3" 3" 3" 3" 3" C&CCC No. 1 5 5 5 5 5 3" Nordstrom 1925 3" Nordstrom 1925 3" Nordstrom 1925 3" Nordstrom 1925 3" Nordstrom 1925 1-1/2" 1-1/2" 1 1 1 OM3-'0 6" VALVE LIST - H3B-R1044 (CONT'D) Number Location Service Size CiCCC No. 4544 HHHH-424 Shutoff 1-1/2" 1 4545 4546 HUHH-425 NOT USED Shutoff 1-1/2" 1 4547 NOT USED 4540 NOT USED 4549 NOT USED 4550 4551 4552 o--1 1 Y NOT USED 6038E-462E Shutoff Drain 1-1/2" 3 A" ]_ 1 4553 HK-491 Shutoff 1-1/2" 1 ---ra -406---------- 1" 1 4556 pp-*4=406- Pressura-Gauge----1/2"------- Shutoff 1" 1 4557 6038E-462 Shutoff 1" 1 4558 1-11-405 Shutoff 2" 1 4559 NOT USED 4560 HK-405 Shutoff l-l A" 4561 HH-405 Check 1-1/2" 2Cl 4562 60381-463 Shutoff 4" 5 4563 IEi-404 Shutoff 1-1/2" 1 4564 6C38E-463 Instrument 1/2" 109 4565 6038E-463 Instrument 1/2" 109 4566 fi jCh*------ EH-492 --*- 'i m4i'*.rUiH/* Shutoff messure uauge 1-1/2" 1 l/2 "------1Q9- 017311 69 VALVE LIST - H3E-R1044 (CONT'D) Number / aAfi 4569 Location Service nfi-407 ------------ fthu+.rif f----- Spare Check 4570 Spare Check 4571 Spare Relief 4572 Spare Relief 4573 Spare Relief 4574 Spare Relief 45 '5 Spare FI or,- Control 4576 Spare Flow Control 4577 Spare Relief 4578 4579 NOT USED Spare Relief 45SG NOT USED Size 1" 2" 2" 3" 3" 3" 3" 1-1/4" 1-1/4" 2" C&CCC No. 1 Vickers No. DF10P1-16-5-20 + Vickers No. DF1CF1-16-5-20 + Vickers No. CF-24-F-10# Vickers Ho. CF-24-F-1CH!- Vickers No. CF-24-F-10* Vickers No. CF-24-F-10* Vickers No. FGY-1C-5C-10 ++ Vickers No. FGY-10-5C-1C ++ Vickers No. CF-16-3-10** 3/4" Vickers No. CT-C6-B-10 *-** + Reference No. (1) on H3B-B1359-1, purchased v.ith 6033E-421, etc.] not shown on flow diagram must be installed v.ith ports of valve in horizontal plane. ++ Reference No. (7) on K3B-B1359-1, purchased with 6C383-4ZL, etc.; not- shown on flew diagram. * Reference No. (3) or. K3B-D1359-I, purchased with 6C38E-421, etc.; not shown on flow diagram. Reference No. (8) on K3B-31359-1, purchased with 6G33E-421, etc.; not shov-n on flcv. diagram. Reference No. (1C) on H3B-B1359, purchased with 6C38E-421, etc.; not shown on flow diagram. 017312 VALVE LIST - H33-R10liii (CONT'D) Number 2*581 2*582 1583 2*582* 1*585 1*586 1*567 1*588 1*589 1*590 1*591 1*592 1*593 1*591* 1*595 1*596 1*597 1*598 1*599 1*600 1*601 1*602 1*603 1*601* Location H-i*5l H-l*5l H--1*52 H--1*52 H--2*53 H--1*53 H-U51* H--1*51* H--1*55 H--1*55 NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED H-i*6l H-i*6l H-lj62 H-i*62 Service Vent Vent Vent Vent Vent Vent Vebt Vent Vent Vent Vent Vent Vent Vent 70 Size 1/1*" 1/li" 1/1*" 1/1*" 1/1*" 1/1*" 1/1*" 1/1*" 1/1*" 1/1*" C&CCC No. 1 1 1 1 1 1 1 1 1 1 1/1*" l/i* 1/1*" iA" I 1 1 1 017313 71 VALVE LIST - H33-R10Uli (COI.T'D) Number Location 160$ H-U63 U606 H-U63 lt607 H-l*61* U608 H-l*61* U609 H-U65 U610 H-U65 h6ll Spare I4612 Spare 1*613 Spare 1*611* Spare ij6l5 L616 Spare Spare 1*617 Spare I16I8 NOT USED 1*619 - NOT USED 1*620 1621 NOT USED 6038E-I163 1*622 IVW-lll 1*623 vviv--l*u Service Size Vent lA" Vent lA" Vent lA" Vent lA" Vent lA" Vent iA" Fressure Gauge Pressure Gauge iA" iA" Pressure Gauge iA" Pressure Gauge iA" Relief Valve iA" Check Check iA" iA" Shutoff Control Control ii" 2" 2" C&CCC No. 1 1 1 1 1 Vickers #13k6H>"Vickers #13ii6H* Vickers #13l62l* Vickers #13il52l* Vickers #C-175-C-10 + Vickers #C2-800** Vickers #C2-800** 5 Powell Fig. 957 or equal Powell Fig. 957 or equal * Reference No,(18) on H3B-B1359-1* purchased with 6038E-U21, etc,j not shown on flow diagram. + Reference No. (20) on H3B-B1359-1> purchased with 6038E-U21, etc.; not shown on flow diagram. ** Reference No. (21) on H3B-B1359-1, purchased with 6038E-U21, etc.; not shown on flow diagram. 017314 VALVE LIST - H3B-R10ii2i (CONT'D) Number h62h L625 U626 1(627 U628 Ii629 li630 L631 1(632 L6 33 h63h U635 I1636 1(637 1(638 U639 L6L0 li6la 1(6L2 1(6 u3 1j61(1( l(6h5 Location VH7-102 W7-U12 VJW-103 WY-U13 wv-iai( WlY-lOl* w,v-ia5 ww-iii5 NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED 6038E-1(63E -XUijO^ C 6038E-1(63 -AA-llO(r Service Control Control Control Control Control Control Control Control Drain Shutoff Check Vent 72 Size 2n 2" 2 2" 2" 2" 2" 2 it C&LfCC No Pcurell Fig. 957 or equal Powell Fig. 957 or equal Powell Fig. 957 or equal Powell Fig. 957 or equal Powell Fig. 957 or equal Powell Fig. 957 or equal Powell Fig. 957 or eaual Powell Fig. 957 or equal 3/h" 1" l(ii 1" 1 1 20li 1 017315 73 Sheet 1 of 3 6038E-U01 thru -4lC, -U71 6038S-ii01A thru -U.CA, -U7Li Rovisod August 22, 19$2 SPECIFICATIONS FOR HYDRAULIC OIL PUMPS ITEMS 60382-U01 THRU -lilO, --U71 IT5I5 6033E-U0L. THRU -uLGA, -U7IA I tens 6038E-UOI thru -LuO, and -U71 Eleven (11) Vickers Model No. PV-2500-FHE veriable delivery piston pumps with specifications of each to be as listed below. Clockwise rotation facing drive shaft. (R) Items 6C38e4tj1.. thru -UlOA, and -u7lA Eleven (11) Vickers Model No. PV-2$00-FHE variable delivery piston pines m-ith specifications of each to be as listed below. Countercleclr.-.'ise rotation facing drive shaft. (P.) OPERATING E..TA Maximum delivery Maximum discharge pressure Sneed Fluid Drive Supercharge '.pressure range to U5C gallons per minute 2,000 lb rer sa in. 720 rpn Tcrosso 52 or equivalent oil Synchronous motor 225 lb per sq in. GO GEIEHA-E DESIGN The pur.p is to be a variable delivery axial piston punp of suitable design and materials to permit 2ii hours per day continuous operation under the above operating conditions. Pump should be capable of change to opposite direction of rotation by minor field alteration. Pumps ..'ill bo mounted in pairs for direct drive by double shaft extension synchronous motors. Handwheel control of pump deliverge is to be -Tovidcd, with a lock screw to serve f or locking the control at any desired setting. An indicator calibrated for the per cent delivery should be included with this control. Each pump except as noted below is to bo equipped math a Thomas Flexible Coupling for connecting to 700 hp motor. Motor half of coupling to (R) be berod to fit motor shaft. Purchaser will supply pump manufacturer with certified motor print for this purpose. Sparc pumps 603SE-u71, and -U71A arc each to be provided 7d.th the pump half of the above-mentioned Thomas coupling. Formy-four (ah) Vickers I5h960 Flanges complete with insert, gaskets, (R) studs, lockwnshors, and nuts shall be supplied with these pumps. Flanges to be machined for socket welding of Schedule 160 steel pipe, size as determined from suction connection. 017316 7h Sheet 2 of 3 6038E-U01 thru -ulO, -U71 6038E-U01A thru 4aa'., -y7L* Revised August 22, 1952 INSPECTION AUD TESTINS (R The Pierchaser or his agent shall have the privilege of inspection at all times during the nanufacturc and testing of the equipment. No parts shall be repaired orithout the rjritten approval of the Purchaser or his agent. All pressure tests of the equipment or of its parts shall be witnessed by the Purchaser or his agent, .'.dvancc notice of at least tv:, days of such testing shall be given. TESTS Pump is to pass a performance tost at the Manufacturer's shop before shipment. The conditions of the test, which are to be mutually acceptable to the Purchaser and to the Manufacturer, arc to be of sufficient severity to insure the meeting of the pump operating requirements without excessive oil leakage or loss of efficiency. The conditions of the test are to be such as to guarantee the pumps meeting the requirements for standard of quality. CERTIFICATE OF TEST Manufacturer shall provide Purchaser -.vitli a certificate covering the results :f the tests. 3tv q The Manufacturer agrees to replace without charge, fob factory shipping point, his optica, to all or.; credit for any articles of his manufacture which under recommended 'esc and service, in his judgment prove to be defective in material or worimianship vrithin a period of one year from the date the material is placed in service. Warranties on materials supplied by others than the pump manufacturer arc to be assigned to the Purchaser. 017317 75 Sheet 3 of 3 6038E-u01 thru -110, -U71 6033S-UGL; thru -idLOA, -1*711 Revised August 22, 19%2 DRAFTINGS Five copies of Nanufacturor1 s outline dimension drawings shall be furnished for npp~ oval and shall be approved before fabrication is staxtod. (..) Eleven copies of certified drawings shall be furnished. EXPEDITING (A) Ex editing -.ill be perf.orr.ed by Brorna and Root, Inc., Houston, Texas. ccrres?o:de.:;e (a) All correspondence pertaining to this equipment, including drawings, test notices, etc., shall be addressed to fir. J. C. Sillin, Brovn and R.:t, Inc., P. 0. Box 3, H'uston 1, Toxa.s. 017318 76 Sheet 1 of 2 6038E-U013 thru -JJLOB Revised November 5 1952 SPECIFICATIONS FCR SrECHEOr'CUS MOTCRS ITEM 6038S-U013 THRU -Ul03 Ten (10) 700-hpj 720-rpn, ljl60-volt, 3-phase, 60-cycle, 100% power factor U0C rise continuous sleeve bearing synchronous horizontal motors rith standard torque (U0% starting, bO pull-in, 1$0% pull-out at normal load inertia). Supply manually operated motor field rheostats suitable for back of panel mounting. Press on drive half-coupling supplied by purchaser. In-rush current not to exceed 500fu of noriaal. Further detailed specifications for each arc as f ollcr.;s: SERVICE Motor vri.ll be coupled to two variable delivery constant speed hydraulic oil pumps. Motor is to be provided with a double shaft extension for coupling to pumps. Shaft extensions are to be equal. Field winding is to be for 125 volts separate excitation. Exciter lead shall not enter through end bell. TP 1 **77 1 VT) :uoi..u Drip-proof type housing. :SED COLLECTOR SINGS Collector rings are to be enclosed in vapor-tight box. Box is to be of suitable working pressure for maintaining of adequate higher pressure of neutral atmosphere around the rings. BEARINGS Ring-oiled sleeve bearings shall have a length not less than the shaft diameter. DIIS'.ISIOIS Overall length, tip to tip of shaft (including extension) - 79-7/8" Shaft extension, each end - 10-1/2" Dimension across feet transverse to shaft - U5" max. Centerline of shaft to bottom of feat - 38" Shaft ciiamct-r - U.375" Rotor shall be symmetrical insofar as practical. The junction box for the lALbO-vclt wiring and exciter wiring should not extend beyond limits of motor housing. L*"\ --- T~ ir\ 017319 The pump loading capacity will be adjusted to the load capacity of the motors. 77 2 of 2 6033E-U013 thru -hlOB Revised Ncrrembcr 5, 1952 GUARANTEE The lianufacturer shall guarantee the above equipment against defects in material or workmanship for a period of one year. In the event of mechanical defect or failure within this period the Manufacturer shall repair or replace the equipment or parts thereof, as may be required, fob shipping point. DFu'-.'MNGS Five copies of Manufacturer's outline dimension drawings shall be furnished for approval and shall be approved before fabrication is started. (A) Eleven copies of certified drawings shall be furnished. EXPEDITING CO Expediting v.*ill be performed by Brown and Root, Inc., Houston Texas, C ORRES PONDZECE (A) All correspondence pertaining to this equipment, including drav.ings, test notices, exc,, shall be addressed to Lir. J. G. Sillin, Brown and Root, Inc., P. 0. Box 3, Houston 1, Texas. 017320 76 Sheet 1 of 1 603SE4i01C thru -iaoc Revised August 22, 1952 SPECIFICATIONS FOR HYDRAULIC OIL PUHP BASE PLATES ITEMS 60385-hQlC THRU -hlOC Ten (10) hydraulic oil pumps and motor base plates each to be suitable for mounting a 700 hp double shaft extension synchronous motor (DO connected through flexible couplings to drive two hydraulic oil pumps (see "Specifications for Hydraulic Oil Pumps, Item 6038E-ii01"). Base plates to be of welded steel construction, suitably reinforced. Base plates to be sloped to permit collection of oil leakage from pumps and connecting piping, and should be provided v/ith suitable collecting troughs. Sufficient machined surfaces shall be provided on the base plate for accurate alignment and assembly of the pumps and motors. They shall be smooth finished and have a good worlonan- like appearance, Kotor and pumps to be aligned on base p.late. Base plates to be shipped less pumps and motors, Manufacturer shall advise Purchaser whether he will need one of the 700 hp motors to properly align pumps and motor on base plates or (R) whether a certified motor print will surfice, DRAWINGS (A) Five copies of Manufacturer's outline dimension drawings shall be furnished for approval and shall be approved before fabrication is started. Eleven copies of certified drawings shall be furnished. EXPEDITING (/.) Expediting vd.ll be performed by Brown and Root, Inc,, Houston, Texas. C CRRES PC. PENCE (i) All correspondence pertaining to this equipment, including drawings, test notices, etc,, shall bo addressed to Mr, J. C. Sillin, 3rown and Root, Inc., P. 0. Box 3, Houston 1, Texas. 017321 79 Sheet 1 of 2 6033E-U01E thru -ItLOE, -U73 and -u73A 6038E-U01E-2 thru -.101-2 Revised October 28, 1952 SIECIFIC. Oh'S FOR 30LZN0ID-OPER;;TZD FOIE-KAY VALVES ITEUS 6038E-UOIE THRU -hlOZ, -h73 AIID -h73A 6038E-g01E-2 THRU -ifLCE-2______________ Twelve (12) double-solenoid, pilot-operated, four-way valves; 6" la-way Model E0-10963-E; l/L" pilot U-way Model DGUSU-022-20; sub-plate DGSH-C2-10. Specifications follow: OPERATE*} COMPETECHS Working pressure Fluid Power supply Maximum operating volume 2,000 psi Teresso 52 or an equivalent oil 110-volt, 60-cycle, a.c. ApprozaLmately 900 gpm }E - 'ZEAL DESIGN Valve is to be indirectly operated by pilot valves actuated by solenoids. Valve to have following characteristics: Fosition 1 - Pressure Port connected to Port A Port B connected to Tank Position 2 - Pressure Port connected to Port B Tort A connected to Tank Reversals of'the valve aro to be shock-free and essentially instantaneous. The valve is to be furnished with sealing elements and suitable forged steal flanges. Alloy steel bolt studs are to be furnished as per ASTM Spec. A-193-U6T, Grade 3ii or 37. Steel lockwashers and nuts to be furnished. Hating flanges to be machined for socket welding of Schedule l60 steel pipe. oQ3SS-dCLE-2 THRU -ilOE-2 (A) Supply ten (10) solenoid and bracket ssenblies for the l/U" pilot u-way valve. These assemblies will be used as spares. TESTS Valve must pass a satisfactory performance test and a U,000 lb hydrostatic test at the Manufacturer*s shop before shipment. The conditions of test, which are to be mutually acceptable to the Purchaser and to the Manufacturer, are to be sufficiently severe to insure the meeting of the operating requirements. 017322 80 Sheet 2 of 2 6038E-UOIS thru -iilOE, -U73- and -U73A 6038E-a0IE-2 thru -ulCE-2 Revised October 2G, 1952 CERTIFICATE CF TESTS Manufacturer shall provide Purchaser with a certificate covering the results of tests. The Manufacturer agrees to replace, fob factory shipping point, or at his option, to allow credit for any articles of his manufacture which under recommended use and service, in his judgment, prove to be defective in material or workmanship within a period of one year from the date the material is placed in service. DE.V.7ITGS Five copies of Manufacturer* s outline dimension drav.dngs shall be furnished far approval and shall be approved before fabrication is starred. Eleven copies of certified bran-ings shall be furnished. EEEEDITITCExpediting '.rill be performed by 3rown and Root, Inc., Houston, Texas. C CERES PCX DEUCE All correspondence pertaining to this equipment, including drawings, test notices, etc., shall be addressed to hr. J. C. Sillin, Brcrm and Root, Inc., F.C. Box 3, Houston I, Texas, 017323 81 Sheet 1 of 4 603SE-421 thru -425, -476 6038E-421A thru -425A 6038E-421B thru -425B 6038E-421M thru -425M, -478 Revised September 15, 1952 SPECIFICATIONS FOR SUPERCHARGE PUUP TAKK UNITS AMD LJSCEILAHEOUS ACCESSCRIES ITELB 6038E-421 THRU -425, -476 ITE1E 6C38E-421A THRU -425A ITEMS 6038E-421B THRU -425B ITEIS 6038E-421H THRU -425M. -478 Reference Drawing H3B-51359-1 Five (5) supercharge pump tank units completely assembled for connecting to (R) Customer's cicing each to include pumps, motor, tank, anc accessories in accorcance v;ith the following specifications. Inching pressure range to 425 psig; pilot oil pressure range to 325 psig. IIEL5 603SS-421 THRU -425 Five (5) Vickers VF3-60-60-M pumps mounted on Items 6038E-421A. thru -425A described below. Fluid pumped - Tsresso 52 or an equivalent oil. Each pu :p to be equipped with a Falk ''Steelflex'1 coupling for connecting to motor drive described below. Motor half of coupling to be bored for motor shaft. (R) ITEIS 6038E-42IM THRU -425M (A) Five (5) Vickers V-124-10-LH pumps mounted on Items 6G38E-421A thru -425A. Fluid pumped - Teresso 52 or an ecuivalent oil. Each pump to be equipped with a Falk "Steelflex" coupling for connecting to motor. Motor half cf coupling to be bored for motor shaft. ITEMS 603SS-421A THRU -425A Five (5) atmospheric working pressure hydraulic oil reservoirs with a capacity of 70C gallons. Tank to have two 3" and one 2" connection in each end, one 1-1/2- connection in too for filling, and openings for cleanout. Exact locations of end connecti ns to be given on approval drawings. An oil level sight gage is to be provided. Tank top to be provided with a means of collecting oil leakage, and piping away cf same. (R) Cleaning - Before testing, the inside of tank is to be sand-blasted po remove all. rust and scale. After testing, tank is to be wiped oup, and. coated with turbine oil. Protection is to be provided so thap water '..all wot enter the tank subsequent to cleaning and oiling, during handiwng and transit. 017324 82 Sheet 2 of 4 6038E-421 thru -425, -476 6038E-421A thru -425A 6038E-421B thru -425B 603SE-421M thru -425U, -478 Revised September 15, 1952 ITSIS 60385-421A THRU -425A (CONT'D)- Tests - After complete fabrication, tank is to be set level and filled v.-itli kerosene. Allow to set for several hours until inspection is made and there is assurance that no leaks are present. Any leaks discovered arc to be repaired after wliich the kerosene test must be repeated, ITEM 603SE-476 One (1) V..ckers VF3-60-6Q-1I pump only, duplicate of Items 6033E-421 thru -425, but -,:ith half coupling oily. ITEM 6038S-478 One (1) Vickers V-124-10-LH pump only, duplicate of Items 6038E-421M thru -425K, but eith half coupling only. ITEIS 6033E-421B THRU -425B Five (5) 50-hp. 440-volt, 3-phase, 60-cycle, explosion-proof motors for Class I, Group D service to be supplied by Vickers, Incorporated for driving Supercharge Units. Motors to be mounted on tank unit. ACCESSORIES AND Provided v/ith the tank unit are to be suitable pump suction piping and Purolator type filters, hydraulic valves for the control of the pressure and flow from the previously mentioned pumps as well as accumulator, valves, filters, and other items necessary to provide a satisfactory hydraulic circuit for driving a pair of double-acting pressure intensifies when combined Y.uth the hydraulic oil pumps and solenoid-operated four-way valves described in accompanying specifi cations, see "Specifications for Hydraulic Pumps, Items 6038E-401, etc. and "Specifications for Solenoid-Operated Four-Aay Valves, Items 6038E-4C1E, etc." Pining on Tank Unit All piping shall he schedule 160 seamless steel -iSTLI A-106 Grade A, Fipe fittings shall be forged steel socket weld type ASTM A-105, Grade 1 for schedule 160 pipe. Ells to be Vogt Figures C-232, etc., or equivalent. Tees to be Vogt Figures C-246, etc., or equivalent. Completely assembled unit (excluding tank) shall be hydrostatically tested at 15C0 psi and shewn to be free of leaks. The piping arrange ment shall be subject to the Purchaser's approval. 017325 83 Sheet 3 of 4 6038E-421 thru -425, -476 6038E-421A thru -425A 6C38E-42IB thru -425B 603SE-421M thru -425M, -478 Revised October lk, 1952 ACCESS CRIES AND ARRANGKENT (CCNT'D) A detailed listing of accessories follows: (reference nuntoers are shown on H3B-B1359-1) (R) Ref. No. No. Rco*d. Description Model No. (1) 22 (2) 42 (3) 24 (4) 66 (5) 6 (6) 22 (7) 12 (8) 6 (9) 18 (10) (ID (12) (13) (14) 6 12 6 6 12 (15) 24 (16) 11 (17) 1 (18) (19) (20) (21) (22) 24 10 11 22 6 Vickers Check Valves Vickers Flanges - bored for Schedule 160 pipe Vickers Relief Valve Vickers Flanges - 44 bored for Schedule 160 pipe 22 blank Vickers Solenoid-Operated 4-way valves Vickers Flanges - bored for Schedule 160 pipe Vickers Flew Control Valves and Sub plates Vickers Relief Valves Viclcers Flanges - bored for Schedule 160 pipe Vickers Relief Valves Vickers Pressure Gauges Vickers Venturi Filters Vickers Venturi Filters Vickers Flanges - bored for Schedule 160 pipe Vickers Pressure Gauges Vickers Hydraulic (Oil) accumulators Vickers Precharging Hose Assembly Vickers Needle Valves Vickers Needle Valves Vickers Relief Valves Vickers Check Valves Vickers Relief Valves DF10P1-16-5-20 (2") FL-l6-TS-20-Spec CF-24-F-10 (3") FL-24-TS-20-Spec (44 required) FL-24-0S-20 (22 required) (R) DF5S4-160C-20 (2") FL-l6-TL-20-Spec (16 required) FL-16-TS-20-Spec (6 required) FGY-10-50-10 (1-1/4n) CF-16-3-10 (2") FL-l6-TS-20-Spec CT-06-3-10 GS-1200 GF1-06-20 (3/4") 0F1-16-30 (2") FL-16-TS-20-Spec GS-3000 4L-2050-10 129312 1346a 8071 C-175-C-10 (1/4") C2-800 (1/4") CT-10-B-10 (A) Valves are to be furnished with sealing elements. Alloy steel bolt studs are to be furnished as per aSTli Specification A-193-46T, Grade B4 or B7. .11 studs shall be marked as required by theTISTIl Specifi cation. Steel lockwashers and nuts to be furnished. Flanges mo be machined for socket welding of Schedule 160 steel pipe. (R) 017326 8h Sheet 4 of 4 6038E-421 thru -425, -476 6038E-421n. thru -4254 6038E-421B thru -4253 6038E-42BJ thru -425M, -476 Revised September 15, 1952 GUARANTEE The Manufacturer agrees to replace without charge, fob factory shipping point, or at his option to allow credit for any articles of his manufacture which under recommended use and service, in his judgment, prove to be defective in material or 'workmanship -within a period of one year from the date the material is placed in service. DRAWINGS Five copies of Manufacturer*s outline dimension drawings shall be furnished for approval and shall be appro-zed before fabrication is started. Eleven copies of certified drawings shall be furnished. EXPEDITING Expediting vd.ll be performed by Brown and Root, Inc., Houston, Texas. CORRESPONDENCE All correspondence pertaining to this equipment, including drawings, test notices, etc., shall be addressed to Mr. J. C. Siliin, Brown and Root, Inc., P. 0. Box 3, Houston 1, Texas. 017327 85 Sheet 1 of 2 6038E-U31 thru -Li35> and -Ii75j 6038E-i;31A thru -U35A November 5, 1952 SPECIFICATIO-5 FCR OIL PEJPS EU IPS - ITEMS 6038S-U31 THRU -U35, AID -U75 MCTCRS - ITEIS 6Q38E-U31A THRU -U35A Five (5) punning units comprising centrifugal pimps, motors, and bases for mumps and motors. Pumps are to be ball bearing, single-stage '.7ith bronze impeller and mechanical shaft seal, to be directly connected to an electric motor by means of Falk flexible coupling, including the coupling. One (1) Dumn as above without base plate or motor but with half coupling. The pumps are to be designed to meet the following Performance Specifications and Guarantee: PEEFCRI.AHCE SPECIFICATIONS Fluid Net positive suction head Discharge head Capacity Motor C harac teris tics Operation Cil temperature Connections TTA n ^ TT-'-'T* Teresso 52 Oil 1 ft above pump suction 75 ft above suction head 100 gpm 3600-rpm, UiO-volt, 3-phase, 60-cycle for operation in Class I, Group D hazardous atmosphere To be non-overloading under all conditions of operation 2h hours uer day I30F Sizes 1-1/2" and larger Manufacturer shall guarantee the pump to operate satisfactorily and continuously in accordance with the specifications contained herein. If the pump fails to meet the guarantee, the Manufacturer agrees to furnish a new pump or redesign the pump furnished so that the guaranteed operating conditions will be met without cost to the Purchaser, fob factory shipping point. The Manufacturer shall guarantee the pump to be free from all defects in design, worlaaanship, and/or material and shall agrea to replace at his own expense, any part of the equipment proving defective within one year of the date of acceptance, provided that the defect existed at the time of acceptance or was caused by poor design, workmanship and/or material. 017328 86 Sheet 2 of 2 6038E-431 thru -h33 and -h70i 6038E-U31 thru -4t35A November 5, 1902 INSPECTION AND testing The Purchaser or his agent shall have the privilege of inspection at all times during the manufacture and testing of the equipment. Five copies of certified hydrostatic test reports shall be furnished. DPJT.TNGS Five copies of Manufacturer's outline dimension drawings shall be furnished for approval and shall be approved before fabrication is started. Ten copies of certified drawings shall be furnished. OPERATING INSTRUCTIONS AND PERFORMANCE CIRVES Eleven copies of certified operating instructions and performance curves shall be furnished. INSTALLATION INSTRUCTIONS AND REPAIR PARTS LISTS Seven copies of certified installation instructions and repair parts lists shall be furnished. EXPEDITING Expediting will be performed by Brown and Root, Inc., Houston, Texas. CORRESPONDENCE All correspondence pertaining to this equipment, including drawings, test notices, etc., shall be addressed to lir. J. C. Sillin, Brown and Root, Inc., P.0. Box 3, Houston 1, Texas. 017329 87 Sheet 1 of 2 6038E-Wj1 thru -150 Revised December 9, 1952 . SPECIFICATIONS FOR OIL COOLERS ITEf.E 603 8E-151 THRU -150 Ten (10) single-pass shell four-pass tube oil coolers Tilth removable bundles, two piece channel, and shell supports all in conformance with T.E.M.A. Standards and equivalent to U-69 construction. Coolers to operate continuously in accordance with the following performance data: (R) PERFORMANCE DATA Shell Side Tube Side Fluid Quantity of fluid Specific gravity Viscosity Temner ature in Temperature out Number of passes Maximum allowable pressure drop Heat transferred Operating pressure Working pressure Hydraulic oil 100 gpm 0.85 300 SSU 128*F I03F One 10 psi 500,000 btu/hr 27 psi 75 psi Water 100 gpm maximum -- -- 95 F (R) 105 F Four () 2 psi 500,000 btu/hr 25 psi 75 psi CONNECTIONS Shell and channel connections to be Manufacturer1s standard but Purchaser shall have the privilege of specifying orientation on approval drawings. GUARANTEE The Manufacturer shall guarantee the equipment to operate satisfactorily and continuously in accordance with the specifications contained herein. If the equipment fails to meet the guarantee, the Manufacturer agrees to furnish new equipment or redesign the equipment furnished so that the guaranteed operating conditions will be met without cost to the Purchaser fob factory shipping point. The Manufacturer* shall guarantee the equipment to be free from all defects in design, workmanship, and/or material. He agrees to replace at his own expense any part of the equipment proving defective within one year of the date of acceptance provided the defect existed at the time of acceptance or was caused by faulty design, workmanship, and/or material. 017330 88 Sheet 2 of 2 6038E-Uhl thru -U50 Revised December 9, 1952 DRAWINGS Five copies of Manufacturer's outline dimension drawings shall be furnished for approval and shall be approved before fabrication is started. Ten copies of certified drawings shall be furnished. (R) INSPECTION AND TESTING The Purchaser or his agent shall have the privilege of inspection at all times during the manufacture and testing of the equipment. (A) Advance notice of at least one week that fabrication is to begin shall be given. Ail pressure tests of the equipment or of its parts shall be witnessed by the Purchaser or his agent. Advance notice of at least three days of such testing shall be given. EXPEDITING (A) Expediting will be performed by Brown and Root, Inc., Houston, Texas. CORRESPONDENCE (A) All correspondence pertaining to this equipment, including drawings, test notices, etc., shall be addressed to Mr. J. C. Siilin, Brown and Root, Inc., p.O. Box 3, Houston 1, Texas. 017331 89 Sheet 1 of 2 6033E-U62+ ' Revised June 19, 1952 ' . SPECIFICATIONS FOR PRESSURE VESSEL its;.: 6o385-U62 One (1) 72" OD x 2ot - 0" overall length pressure vessel with ASI.E flanged and dished heads to be fabricated in accordance with these specifications and the following design data: DESIGN DATA Working pressure Drawing Construction ?G psig C&COC HJB-B1080 Class B ocr C&CCC Standard Specifications DTD-101, PVF-101, PVN-lOO, end FT'-101 Stress relief, radiography, and magnetic particle inspection not required. Joint efficiency 80$ CONTECTICl'S Nozzle No. Size ' -X. 1 20" B 1 2" C, D 2 1-1/2" E ]_ 3" '7? lpC# 150 15C# 15 Of? Type ASA welding neck ASA welding neck ASA welding neck ASA welding neck Facing 1/16" raisod face 1/16" raised face 1/16" raised face 1/16" raised face -"-Supply one 20", 150 psi ASA blind flange. i-TSD-L-LS OF CONS'T'-UCTION Per PVF-101, Table 11, Group 1 and following: 1 - Shell and heads - ASTI A-2C-ii9T, Grade C, Firebox Quality. 2 - Nozzles - ASTH A-181-U9, Grade 1, 3 - Pipe - ASTM A-10O-U3T, C-radc A. k - Bolts and nuts - PVT-100, Class 1. 5 - Gaskets - U. S. Rubber lie. ):399 or equal. inspection testing The Purchaser or his agent shall have the privilege of inspection at all tir.es during the manufacture and testing of the equipment. Advance notice of at least one week that fabrication is to begin shall be given. (11) All pressure tests of the equipment or of its parts shall be witnessed by the Purchaser or his agent. Advance notice of at least two days of such testing shall be given. -Item was E-b62, 017332 90 DRA.1NGS Sheet 2 of 2 6038E-U62 Revised June 19, 1952 (A) Five copies of Manufacturer*s shop drawings shall be furnished for approval, and shall be approved by Purchaser before fabrication is started. Eleven copies of certified drawings shall be furnished. EXPEDITING (A) Expediting will be performed by Brown and Root, Inc., Houston, Texas. CORRESPONDENCE (l) 111 correspondence pertaining to this equipment, including drawings, test notices, etc., shall be addressed to lir. J. C. Sillin, Brown and Root, Inc., ?. 0. Box 3, Houston 1, Texas. 017333 91 Sheet 1 of 2 6038E-U63* Revised June 19, 1952 SPECIFICATION FOR PRESSURE VESSEL ITEM 6Q38E-U63 One (1) U* - 0" OD by 12 - 6" long horizontal pressure vessel with ASIE flanged and dished heads to be fabricated in accordance with these specifications and the following design data: DESIGN DATA Working pressure Drawing Construction 50 psi C&CCC H3B-C1081 Class B per C&CCC Standard Specifications PVD-101, PVF-101, PVH-100, and F7W-101 Stress relief, radiography, and magnetic particle inspection not required. Joint efficiency 80j CONNECTION No. Size NT Type Facing Shell 1 20" 150if 2 h" 150? ASA welding neck with cover 1/16" raised face ASA welding neck 1/16" raised face Cover 1 1 2 3" 15<# 2" 150? 1-1/2" 150^ ASA '.veiling neck ASA welding neck ASA welding neck 1/16" raised faceVl6" raised face 1/16" raised face :`i/.T'~iruALS OF CONSTRUCTION Per fvf-ioi. Table 11, Group 1 and following: 1 - Snell and heads - ASTM A-2G5-U9T, Grade C, Firebox Quality, 2 - Nozzles - AST:; A-131-U9, Grade 1. 3 - Pipe - ASTM A-IO0-U8T, Grade A. a - Bolts and nuts - PVM-100, Class 1. 5 - Gaskets - U. S. Rubber No. u399 or equal. --Iter. was E-U63. 017334 92 Sheet 2 of 2 o038E-U6>* Revised June 19, 1952 IISFECTIO'1 AND TESTING The Purchaser or his agent shall have the privilege of inspection at all times during the manufacture and testing of the equipment, (K) advance notice of at least one week that fabrication is to begin shall bo given. All pressure tests of the equipment or of its parts shall be witnessed by the Purchaser or his agent. Advance notice of at least two days of such testing shall be given. DRA'.YIHGS Five copies of Manufacturer's shop drawings shall be furnished for approval, and shall be approved by Purchaser before fabrication is started. Eleven copies of certified drawings shall be furnished, EXPEDITING r Expediting will be performed by Brorm and Root, me., Houston, Texas, COR RESPONDSI :CE (..) All correspondence pertaining to this ecuipmeat, including drawings, test notices, etc., shall be addressed to Nr. J. G, Sillin, Brown and Root, Inc,, ?, 0. Box 3, Houston 1, Texas, 017335 93 Sheet 1 of 2 6038E-U6U November 5, 1952 SPECIFICATION F3R III PIP.IFIER item 6o38e-U6U GENERAL DESIGN One (1) portable centrifugal oil purifier, DeLaval Model No. U5, complete with constant efficiency, corrosion-resistant, disc-type bowl, hinged covers, inspection ports, test cocks, built-in intake and discharge pumps, and an automatically and thermostatically controlled heater. To be mounted on a portable steel platform with four rubbertired wheels and drawbar. To be direct-driven by a 1/2 hp UiO-volt, 3-phase, 60-cycle electric motor. Heater, motor and starters to be designed for use in Class I, Group D, hazardous locations. SERVICE To purify Teresso 52 hydraulic oil for use with hydraulic pumps. C .No0:. To be supplied with two (2) 20 ft lengths of 3/u" oil-resistant flexible hose for use in the transfer of oil to and from purifiers. GUARANZE _ The Manufacturer shall guarantee the unit to Operate satisfactorily i : accordance with the recommended service. In the event the unit fails to meet this guarantee, the Manufacturer agrees to furnish, without cost to the Purchaser, a new unit or alter the unit furnished so that the guaranteed operating performance will be obtained. The Manufacturer shall also guarantee the unit to be free from all defects in design, workmanship, and/or material, and shall agree to replace, at his own expense, fob factory shipoing point, any part of the equipment proving defective within one year of acceptance date, provided that the defect existed at the time of acceptance, or was caused by poor design, workmanship, and/or material. DRAWINGS Five copies of Manufacturer's outline dimension drawings shall be furnished for approval and shall be approved before fabrication is started. Ten copies of certified drawings shall be furnished. 017336 9h INSTALLATION IISTP.XTIONS A! REPAIR PARTS LISTS Sheet 2 of 2 603SE-U6ii November 5, 1952 Seven copies of certified installation instructions and repair parts lists shall be furnished. EXPEDITING Expediting will be performed by Brown and Root, Inc., Houston, Texas. ccrrespcrdence All correspondence pertaining to this equipment, including drawings, test notice:., etc., snail be addressed to J. C. Sillin, Bream and Root, Inc., F.O. Box 3, Houston 1, Texas. 011331 SPECIFICATIONS FOR OIL FILTERS Sheet 1 of 2 6038K&98 and A98A Revised May 7, 195^ ITEMS 6038E-h98, -49SA Two (2) Hlleo Bvflov Oil niters. Model HFC-18-7F, complete with cover-lifting device, Internal relief valves, Inlet and outlet pressure gauges and Type FW-718 cellulose disc cartridges. The filter shall aeet- the following specifications: (R) OPERATING CONDITIONS Service - Continuous filtering of hydraulic fluid Fluid - Standard Oil Company1s Esstic 55 Fluid gravity - 0,85 at Viscosity - U30 SSU at 100*F; 120 SSO at 150*F Operating temperature - 100F to 150*F Minimum size particle to pass - 0.001" Volume of fluid - 300 gpm Permissible pressure drop across filter - 30 psl (R) DESIGN Working pressure - 75 psl Materials: head and sump - Manufacturer's standard filter elements - Cellulose cartridge. Connections: inlet and outlet - 6b flanged DRAWINGS <H) Five copies of Manufacturer's outline dimension drawings shall he furnished for approval and shall he approved before fabrication is started. Eleven copies of certified drawings shall he furnished. INSTALLATION AND OPERATING INSTRUCTIONS Seven copies of certified Installation and operating instructions shall he furnished. EXTRAS TO BE FURNISHED (A) A total of two (2) extra sets of 18 Type FW-718 cellulose disc cartridges shall he furnished. 017338 Sheet 2 of 2 6036E-496 and -U9&A Revised May 7, 195^ OOARAHTEE Manufacturer guarantees the units to operate satisfactorily and continuously in accordance with the operating conditions contained herein. If units fall to meet the guarantee the Manufacturer agrees at his own expense fob shipping point, to furnish nev units or to redesign the units furnished so that they operate satisfactorily in accordance with the operating conditions in this specification. Manufacturer guarantees the units to be free from all defects in design, workmanship and/or material and agrees to repair or replace at his own expense, fob shipping point, any part of the equipment proving defective within one year of the date of acceptance, provided the defect existed at the time of acceptance or was caused by poor design, workmanship and/or material. 017339 Vj^jV^AN^PIPINC^PECIFICATIOh^ 95 NO. 1 >rish Revised July 25, 1951 Maximum Pressure: Temperature Range: 125 psi (1) 32*F to 450*F (1) 0*C to 232*C PIPING Item______________________________Sine, incl.__________ Specification Construction To 2$" 3" to 8" 10" to 30" Pipe - Material Thickness To l" 2" to 30" To 6" 8" to 12" 14" to 30" F ittings - Elbows, Elbows T ees Unions tees, etc. To 2^" 3" to 8" 10" to 24" 30" 10" to 30" To 2^" Flanges - Type F acing To 8" 10" to 30" To 30" Gaskets To 8" 10" to 30" Dope - Threads and Gaskets Bolts and Nuts - Screwed. Screwed and flanged. Welded and flanged. (2) Galvanized steel: Galvanized steel: Schedule 40. Schedule 20. Schedule 10. ASTMA-120, butt-welded. ASTM A-120, lap-welded. Cast iron: ASA 125 lb. , screwed. Cast iron: ASA 125 lb. , flanged. (2) Cast iron: ASA 125 lb., flanged. (2) Shop fabricated from pipe; reinforced if necessary. Shop fabricated from pipe; reinforced if necessary. Petro or equal. Cast iron: ASA 125 lb. , screwed. Cast steel: ASA 150 lb. , slip-on. Manufacturer's standard. U.S. No. 4009 "Rainbow" or equal; 1/16", full face. U. S. No. 4009 "Rainbow" or equal; 1/8", full face. Red lead. Square head machine bolts, hex nuts. VALVES Service Size, incl. Carbide Number Make and Figure Number Materials Body Trim Type of Ends Shut-off V-Port Control Cock (3) Check Gauge Column Gauge Glass N O CD i"to 2^" 3" to 8" 10" to 30" 3" to 8" " to 2^" 3" to 12" 1" to 2" " to 2*" 3" to 30" li" i" GA-1 GA-5 GA-6 GA-50 GL-104 GL-102 CO-411 CO-412 CK-201 CK-204 GA-17 GC-603 Lunk. 2125 Powell 1444 Crane 465^ Powell 1793 Lunk. 1021 Lunk. 1123 Crane 334 Crane 329 Crane 34 Crane 373 Lunk. 2152 Lunk. 460 Br Br Cl Br Cl Br Cl Br Cl NA Cl Br Cl Cl Cl Br Br Br Cl Br Br Br Br Br Screwed Flanged Flanged Flanged Screwed Flanged Screwed Flanged Screwed Flanged Flanged Screwed Valve Stem Packing To 3" 4" up Garlock 117 or equal. Garlock 150 or equal. 017340 Notes: (1) Pressure and temperature limits are reduced for pipe in sizes over 20", for cast iron fittings and valves in sizes over 12". At 150*F pipe is rated for following maximum pressures: 24"-113 psi; 30"-122 psi. For ratings of fittings and valves refer to manu facturer's catalog. VALVE AND PIPING SPECIFICATION PIPING Revised July 25, 1951 Maximum Pressure: Maximum Temperature: 125 psi 406*F 208* C Item______________________________Site, incl.__________ Specification Construction To 2" Screwed. Pipe To 2" Red Brass: Std. IPS, ASTM B43. Fittings - Elbows, Tees, etc.To 2" Unions To 2" Red brass: ASA 125 lb., screwed. Red brass: Crane Fig. 523^ or equal. Flanges - Type F acing To 2" To 2" Red brass: ASA 125 lb., screwed. Manufacturer's standard. Gaskets Dope - Threads Gaskets - U.S. No. 4899 or equal: 1/16" thick. White lead. Graphite and oil. Bolts and Nuts - Square head machine bolts, hex nuts. 96 NO. 4 VALVES Service Shut-off Control Check Valve Stem Packing Size, incl. i" to 2" i" to 2" to 2" To 2" Carbide Number GA-1 GL-108 CK-210 Make and Figure Number Materials Body Trim Lunk. 2125 Crane 70 Lunk. 554 Br Br Br Br Br Br Garlock 117 or equal. Type of Ends Screwed Screwed Screwed 017341 VALVE AND PIPING SPECIFICATION 97 NO. 5 Revised July 25, 1951 Maximum Pressure: Temperature Range: 125 psi 32*F to 450*F 0*C to 232*C PIPING Item ^izc. incl. Specification Construction To $" 1" - 24" Pipe - Material Thickness Tol|" 2" - 24" To 6" 8" to 12" 14" - 24" Fittings - Elbows, tees. etc. To |" Elbows, stub ends 1" - 24" Tees 1" - 24" Flanges - Type Facing Unions 1" - 24" To 2" Gaskets Dope - Threads Gaskets Bolts and Nuts Screwed. Welded and flanged. Steel: ASTM A-53, Grade A. butt-welded. Steel; ASTM A-106, Grade A, seamless. Schedule 40. Schedule 20. Schedule 10. Forged steel: 2000 lb. (min.) screwed. Steel: butt-welding, seamless, to match pipe. Shop fabricated from pipe; reinforced if necessary. Forged steel: ASA 150 lb. , slip-on or lap-joint type. Manufacturer's standard. Petro or equal. U.S. No. 4899 or equal; 1/16" thick. Red lead. Graphite and oil. Square head machine bolts, hex nuts. VALVES Service Shut-off Control Check Gauge Glass Gauge Column Valve Stem Packing Size, incl. " to 2" 2$" to 3" 4" to 24" i" to 2" 2" to 3" 4" to 12" " to 2" 2" to 3" 4" to 16" i" 1* To 3" 4" up Carbide Number GA-1 GA-17 GA-59 GL-109 GL-110 GL- 143 CK-210 CK-222 CK-203 GC-603 GA-17 Make and Figure Number Material Body Trim Lunk. 2125 Br Lunk. 2152 Br Powell 1503-P-140.CS Lunk. 73 Br Lunk. 70 Br Powell 1531-P-140CS Lunk. 554 Br Lunk. 1305 Br Powell 1561 -P- 140 CS Lunk. 460 Br Lunk. 2152 Br Br Br CrS NA NA CrS Br Br CrS Br Br Garlock Ilf-or equal. Garlock 150 or equal. Type of Ends Screwed Flanged Flanged Screwed Flanged Flanged Screwed Flanged Flanged Screwed Flanged 017342 PIPING Item Pipe t Elbows Tees fa Crosses Reducers Flange fa Spigot Fitting Gaskets Clamps fa Rods Caulking Bolts and Nuts VALVE AND PIPING SPECIFICATION Revised July 25, 1951 Maximum Pressure: 86 psi 98 NO. 21 Size, incl._________Specification 3" to 12" 14" to 24" 30" to 54" Cast iron: centrifugally cast , cement lined, Class 150, bell and spigot, Federal Spec. WWP-421, 18 ft. lengths. Cast iron: centrifugally cast, cement lined, Class 100, bell and spigot, Federal Spec. WWP-421, 18 ft. lengths. Cast iron: pit cast, cement lined. Class 100, bell and spigot, ASA A-21. 2. 3" to 12" 14" to 54" Cast iron, cement lined: AWWA Std. Class D, with bells only and underwriters lugs. Cast iron, cement lined: AWWA Std. Class B, with bells only and AWWA lugs. 3" to 12" 14" to 54" Cast iron, cement lined: AWWA Std. Class D, with bells only. Cast iron, cement lined: AWWA Std. Class B, with bells only. 3" to 12" 14" to 54" Cast iron, cement lined: AWWA Std. Class D, bell and spigot. Cast iron, cement lined: AWWA Std. Class B, bell and spigot. 3" to 12" 14" to 54" Cast iron, cement lined: Class 250 pipe, length to be specified. Fig. 125 lb. Std. Cast iron, cement lined: Class 100 pipe, length to be specified. Fig. 125 lb. Std. 3" to 8" 10" to 54" U.S. No. 4009 "Rainbow" or equal, full face. U.S. No. 4009 "Rainbow" or equal, full face. 1/16" thick, 1/8" thick, 14" to 36" 3" to 12" Carbide Std. P-109, P-110. Carbide Std. P-105, P-106. All Lead and Oakum. All Square head machine bolts, hex nuts. O'l'tt43 99 Sheet 1 of 2 12$ lb Hydraulic Oil Revised November 3, 1952 VALVE AND FIFING SPECIFICATIONS 12$ LB HYDRAULIC OIL SERVICE Operating Temperature Range 'Maximum Pressure Pipe, Fittings, and Flanges Valves 06C to 1006C 12$ psi gauge Steel Steel ana bronze PIPING Item Size (Incl.) Specification Pipe Construction 1/U" 1/2" to 3" 1/2" to 3" Pipe Fittings 1/U" 1/2" x 3/h" 1" to 3" Couplings Yielded into Lines 1-1/2" to 3" Flanges Flange Facing Gaskets Dope Bolting 1/2" to 3"* All* All* All Valve Stem Packing All 3/8" CD x C,C3$" wall seamless steel tubing Schedule 80 seamless steel pipe, ASTI! Spec. A-106, Grade A Fielded and flanged. Fielding rings, if used for sizes 1" and over are to be Wedge Protectors Inc. Type P-UkoA. Do not seal-weld valves. Fieatherhead steel fittings Elbows and tees shall be forged steel socket-weld type, ASTM Spec. A-10$, Grade I for Schedule 80 pipe, Vogt Figs. B-232, etc., or equivalent. Elbows, tees, reducing tees, and straight-through reducers shall be conventional welding fittings; to bo AST:'! Spec. A-106, Grade A, seamless stacl fittings for Schedule 80 pipe. 3/lt" 3000 lb forged steel couplings with outside end reduced to the required pipe size. ASA 1$0 lb forged steel welding neck flanges bored for Schedule 80 pipe. Ring joint groove facing, ASA-Bl6e-1939 Soft Armco iron rings None Bolt studs shall be alloy steel to AST!: Spec. A-193-U6T, Grade B7 or 37a, with two nex nuts each, and threaded full length in accordance with C&CCC Standard Specification T7::-10C, Class I. Lock washers shall be used on all bolt studs. Garlock No. 117 -"-Mote: '.There special flanges arc required for mating to hydraulic equipment, these flanges and the necessary gaskets shall be supplied by the hydraulic equipment manufacturer bored far socket welding. 0173,14 VALVES 100 Sheet 2 of 2 125 lb Hydraulic Oil Revised May 6, 195^ Service Sizes (Incl.) Make Fig. No. C&CCC Type Ends Shutoff Control Check l/V to 2" 2" 3" lA" to 2" l/V' to 2" 3" Lunk 2125 Nordstrom 192^ Nordstrom 1925 Lunk 2125 Crane 3*+ Powell 1561 1 - 1 201 - Screwed Screwed Flanged Screwed Screwed Flanged All other valves to be Vickers, Inc., valves as specified in the Valve List. NOTE All pipe is to be hammered and blown clear after welding and is to be pickled by the following procedure: (1) Prepare solution of 50$ water and 50$ muriatic acid by weight.. Add 0.1$ to 0.2$ by weight of inhibitor to dampen action of acid on steel pipe while retaining action on welding scale. Use Alkyl Pyridine - HB (methyl ethyl pyridine residues) from C&CCC sale's. Dissolve ATkyl Pyridine - HB in 32% hydrochloric~acid Tcammercial hydrochloric; i.e. muriatic) before dilution with water. (R) (R) (2) Fill pipe section with solution and let stand until welding scale is noted to be diseolved (15 minutes to 1 hour depending upon amount of scale. 15 minutes usually sufficient.) (3) Wash pipe thoroughly with water. Dry with air. Flush with alcohol or acetone immediately for complete drying. (M Oil inside of all pipe thoroughly with hydraulic oil following drying. 017345 101 Sheet 1 of 2 300 Lb Hydraulic Oil Revised November 3, 1932 VALVE AND PIPING SPECIFICATIONS 300 LB HYDRAULIC OIL SERVICE Operating Temperature Range Maximum Pressure Pipe, Fittings, and Flanges Valves 0 to 100C 300 psi gauge Steel Steel and Bronze PIPING Item Pipe Construction Size (Incl.) 1/L" 1/2" to 3" 1/2" to 3" Pipe Fittings 1/1" 1/2" and 3/1" 1" tc, 3" Couplings '/elded 1-1/2 to 3" into Lines Flanges 1/2" to 3"* Flange Facing Gaskets Dope Bolting All* All-::- All Valve Stem Pack- All ing Specifications 3/8" OD x 0.035" wall seamless steel tubing Schedule 80 seamless steel pipe, AST"' Spec. A-106, Grade A 7/elded and flanged. 'Jelding rings, if used for sizes 1" and over are to be ".'edge Protectors, Inc. Type P-LU6A, Do not seal-weld valves. V.eatherhead steel fittings Elbows and tees shall be forged steel socket-weld type, ASTM Spec. A-105, Grade I for Schedule 80 pipe, Vogt Figs. B-232, etc., car equivalent. Elbows, tees, reducing tecs, and straight-through reducers shall be conventional welding fittings; to be AST!' Spec. A-106, Grade A, seamless steel fittings far Schedule 80 Dipc. 3/h" 3000 lb forged steel couplings with outside end reduced to the required size. ASA 300 lb forged steel welding neck flanges bored for Schedule 30 oiDe. Ring joint groove facing, ASA-Sl6c-i939 Soft Armco iron rings None Bolt studs shall be alloy steal to ASTI! Spec. A-193-U6T, Grade B7 or 37a, with two hex nuts each, and threaded full length in accordance with C&CCC Standard Specification PVlI-100, Class I, Lock washers shall be used on all bolt studs. Garlock No. 117 -Note: ..acre special flanges arc required for mating to hydraulic equipment, taese flanges and the necessary gaskets shall be supplied by the hydraulic equipment manufacturer bored for socket welding. 017346 VALVES Sheet 2 of 2 300 Lb Hydraulic Oil Revised May 6, 1954 Service Sizes (Incl.) Make Fig. No. C&CCC Type Ends Shutoff Control Check l/h" to 2" 2" to 3" 1" to 2" 1/2" to 2" 3" Vogt 9851-9858 Nordstrom 2025 Vogt 3435-3438 Lunk 62k Powell 3061 55 - 171 212 241 Screwed Flanged Screwed Screwed Flanged All other valves to be Vickers, Inc. valves as specified in the Valve List. NOTE All pipe is to be hammered and blown clear after welding and is to be pickled by the following procedure: (1) Prepare solution of 50# water and 50# muriatic acid by weight. Add 0.1# to 0.2# by weight of inhibitor (R) to dampen action of acid on steel pipe while retaining action on welding scale. Use Alkyl Pyridine - HB (R) (methyl ethyl pyridine residues) from C&CCC sales'. Dissolve Alkyl Pyridine - HB in 32# hydrochloric acid {commercial hydrochloric; i.e. muriatic) before dilution with water. (2) Fill pipe section with solution and let stand until welding scale is noted to be dissolved (15 minutes to 1 hour depending upon amount of scale. 15 minutes usually sufficient.) (3) Wash pipe thoroughly with water. Dry with air. Flush with alcohol or acetone immediately for complete drying. (k) Oil inside of all pipe thoroughly with hydraulic oil following drying. 017347 103 Sheet 1 of 2 2000 lb Hydraulic Oil Revised November 3, 1952 VALVE AND PIPING SPECIFICATIONS 2000 LB HYDRAULIC OIL SERVICE Operating Temperature Range Maximum Pressure Pipe, Fittings, and Flanges Valves 0 to 100C 2000 psi gauge Steel Forged steel PIPING Item Pipe Construction Sizes (Incl.) 1/U" 1/2" to 6" 1/2" to 6" Pipe Fittings l/U" 1/2" and 3/U" 1" to 6" Couplings 7/eldcd into Lines Flanges Flange Facing Gaskets Dope Bolting 1-1/2" to 6" 1/2" to 6''-::All-;:All# All Valve Stem Packing All Specification 3/8" OD x 0,035" wall seamless steal tubing Schedule 160 seamless steel pipe, ASTI: Spec. A-106, Orade A Welded and flanged. Welding rings, if used for sizes 1" and over are to be Wedge Protectors Inc. Type F-UU6A., Do not seal-weld valves. Wcatherhcad steel fittings Elbows and tees shall be forged steel sockct-wcld type, ASTM Spec. A-105, Grade I, for Schedule 160 pipe, Vogt Figs, C-232, etc., or equivalent. Elbows, toes, reducing tees, and straightthrough reducers shall be conventional welding fittings. To be ASTM Spec. A-106, Grade A, seamless steel fittings for Schedule 160 pipe. 3/U" 3000 lb forged steel couplings with outside end reduced to the required size. ASA 1^00 lb forged steel welding neck flanges bored for Schedule 160 eipc. Ring joint groove facing, ASA-Bl6c-1939 Soft Armco iron rings Mono Bolt studs shall be Alloy steel to ASTM Spec. A-193-U6T, Grade B-7 or B7a, with two hex nuts each, and threaded full length in accordance vith C&CCC Standard Specification PVM-100, Class I. Lock washers shall be used on all bolt seuds. Garlock No, 11? -::-Notc: T7here special flanges are required for mating to hydraulic equipment, these flanges and the necessary gaskets shall be supplied by the hydraulic equipment manufacturer bored for socket welding. 017348 VALVES Sheet 2 of 2 2000 Lb Hydraulic Oil Revised. May 6, 195** Service Sizes (Incl.) Make Fig. No. Type Ends Shutoff or Control 1/V' to 2" Vogt 1871-1879 Screwed All other valves to be Vickers, Inc. valves as specified in the Valve List. NOTE All pipe is to be hammered and blown clear after welding and is to be pickled by the following procedure: (1) Prepare solution of 50# water and 50# muriatic acid by weight. Add 0.1# to 0.2# by weight of inhibitor (R) to dampen action of acid on steel pipe while retaining action on welding scale. Use Alkyl Pyridine - HB (R) (methyl ethyl pyridine residues) from C&CCC sale's. Dissolve Alkyl Pyridine - HB in 32# hydrochloric acid {commercial hydrochloric; i.e. muriatic) before dilution with water. (2) Fill pipe section with solution and let stand until welding scale is noted to be dissolved (15 minutes to 1 hour depending upon amount of scale. 15 minutes usually sufficient.) (3) Wash pipe thoroughly with water. Dry with air. Flush with alcohol or acetone immediately for complete drying. (4) Oil inside of all pipe thoroughly with hydraulic oil following drying. 017349 105 } Sheet 1 of 1 November 5, 1952 PROTECTIVE COVERING SPECIFICATIONS FOR UNDERGROUND STEEL LINES AND TANKS This special protection shall apply only to short runs of piping where lines are placed underground between various units of the plant or within a unit. Extended pipe lines shall be protected with the standard Barrett pipe line enamel. The special protection desired shall be applied in the field as follows: 1) Clean all metal parts thoroughly, 2) Apply one coat of Barrett Superservice cement 3/8" thick, 3) Cover with a wrapper of 15 pound tarred felt, U) Apply a second coat of Barrett Superservice cement l/ii" thick, 5) Cover with a wrapper of 15 pound tarred felt. This protection shall also be applied to all rods, clamps, and steel anchors, 017350 PIPING VALVE AND PIPING SPECIFICATION Issued April 30, 1953 Maximum Pressure: 125 psi Temperature Range: 32*F to 450*F 0*C to 232*C 105 R NO Item Construction Pipe - Material Thickness Fittings - Elbows, tees, etc. Unions Flanges - Type F acing Gaskets Dope - Threads Gaskets Bolts and Nuts Size, incl. To 2f' To 2" To 2j" To 2j" To 2i" To 2j" To 2j" - _ - - Specification Screwed. Galvanized steel: ASTM A-120, butt-welded. Schedule 40. Galvanized malleable iron: ASA 150 ib. , screwed. Petro or equal. Cast iron: ASA 125 lb. , screwed. Manufacturer's standard. U. S. No. 4899 or equal; 1/16" thick. White lead. Graphite ar.d oil. Square head machine bolts, hex nuts. VALVES Service Size, incl. Carbide Make and Number Figure Number Shut-off i" to 2j" GA-1 Lunk. 2125 Control Check i" to 2j" i" to 2" GL-108 CK- 210 Crane 70 Lunk. 554 Valve Stem Packing To 2i" Garlock 117 or equal. Materials Body Trim Br. Br. Br. Br. Br. Br. Type of Ends Screwed Screwed Screwed 017351 EUBCTRICAL REPORT SECTiai II 1C6 5 if 5 * Frcparod by H2B Electrical Department . G. 0. u'ardrop . J. C. Norton . J. R. Cooper . J. F. Paden 017352 107 PGhER OIL SISTEM SECTION II This part oi the design report covers the "High Pressure Intensifier Con trols ," \(id.ch electrically controls the oil flow from the power oil units to the high pressure pumping units. Part III, YJP-6037. The pumping u its consist of two cylinders each, physically arranged as "'.Vest" and "East," In operation the east cylinder is the lead cylinder and is 90 ahead of and is also timed by the west cylinder. Limit switches are mounted on the cyl.nd.ers and are operated by mechanical guides. These switches control, through special relay assemblies SK-5Q889, the main control solenoid valves. The valves control the direction of the oil flow. Inching switches are provided for each cylinder for maintenance purposes. These switches control the oil flow from the supercharge oil pump to the pumping units through the inching valve end the main control valves. For wiring diagram see SK-50890. 017353 LIST OF EQUIPMENT 108 Revised 6/16/53 6038E-U01E-1 THRU -hlCE-l Solenoid-operated l/hn pilot four-tray valves. Main control valves for pumping units. See Section I for specifications. Operating coils Operating positions Two - "A" and "B" Two - No. 1 - "A" coil energized No. 2 - "B" coil energized 6038E-U01M THRU -LlOM Limit switches - see Section I for specifications. See SK-50890 for wiring diagram. 6038E-b01N THRU -UlON Limit switches - see Section I for specifications. See SK-50890 for wiring diagram. 6038E-U01P THRU -lilQP Inching switches. General Electric Company Type SB-1, or equal, oil immersed, manually-operated, 6-pole, 3-position, with contacts arranged in accordance with SK-50890. Note: Mount one on west side of each cylinder of pumping units. 6038E-U21C THRU -U25C Solenoid-operated 2" four-way valves. Inching valves for pumping units, see Section I for specifications. Operating coils Operating positions See SK-50890 far wiring diagram. Two - "A" and "B" Three - No. 1 - No*coil energized No. 2 - nAn coil energized No. 3 - "BM coil energized 6o3SE-Ii79. 4i79A. -18C AND -U8QA Spare relay mounting chassis. Each chassis to include the following: (1) Two (2) Cinch Jones molded octal socket number 8 AM. To mount in 1" hole on chassis. (2) One (1) Cinch Jones 6 point Barrier Type Terminal Strip Catalogue No. 6--llt2 (R) 017354 109 Revised 6/16/53 6038E-U79. -U79A. -U80 AMD -liBQA (CONT'D) (3) Two (2) push-button Micro Switch Catalogue No. BZ-2RQ1 (U) Ttk> (2) 600 volt, two micro-farad condensers, Sprague Products Co. Catalogue No. BP-206. (5) One (1) removable chassis wired in accordance with SK-56U58. Note: Enclosure not required. Panels are to be delivered to the Plant CA Operating Department. 6038E-1i81 THRU -185 (R) Relay assemblies in accordance with SK-56U58. Each assembly to include the following: (1) Two (2) removable chassis duplicating 6038E-ij79 etc. (2) Two (2) Electro-Seal Corporation Advance Type 96ii-B relays with octal plug base, drawing A-1180-06, series 18E. Supplied by Electro-Seal Corporation, 9U6 North Avenue, Des Plaines, Illinois. (3) Master terminal strip fastened to enclosure. Use Cinch Jones 12 point Barrier Type Terminal Strip, Catalogue No. 12-11*2 or equal. (U) Suitable enclosure (not oil immersed). 6038E-Ji86 THRU -L95 (R) Spare relays. Ten (10) Electro-Seal Corporation Advance Type 96U-B relays with octal plug base, drawing A-1180-06, series 18E. 017355 (i<On*> m >- - - SVOOC dp ~!~>oa ;L V-' k E MO H\QH PRESSURE 1HTEHS1FTERS CONTR.QV. RELLhY ASSEMBLY . THIS SKETCH SUPERCEDES SK.^OEBS NJITH SKME TlTUE. ' /* ------------------- L-c- engineering department CARBIDE AND CARBON CHEMICALS COMPANY H LVlSOfi Of Utfl.1 CttUK AID CATBCK CUSPufiAT4M SOUlH CliAhtXSlON, WljX VA. DR*moEHH\E M* Afro dau anemia. \ 017359 !LOCS PRESSURE CONTROL SYSTEM AND EMERGENCY BLOWDOWN SYSTEM PER DESIGN REPORT I'M V, MMJIOH 9WM, V/P- 604 0. INTERLOCKED TO THE 700 HP PUMPS SPECIFIED IN PART IT, POWER OIL SYSTEM, WP- 6038 FOR ELECTRICAL CONNECTION DIAGRAM, SEE SK-50B9Z. 5-80KW. ELECTRIC DOWTHERM HEATERS PER DESIGN REPORT PART ZT, DOWTHERM SYSTEM, WP-6040. FOR WIRING DIAGRAM, SEE SK-50893. 017360 DEPARTMENT OF COVSTM'CTIO.V AND DESIGN CARBIDE AND CAVUION CHEMICALS COMrANT A MlltNni or V**imr rARMc i AtM rofm>tTWR SOUTH CIIARIXSTOX. WEST VIRGINIA Raant c* BLOCK DIAGRAM OF ELECTRICAL CONNECTIONS-POLYETHELENE UNIT DRAWN SHivr* TRACED tatio* CTK'D DATE 10-10-St SCAIT SK-50891 T S K -5 0 8 9 0 HIGH PRESSURE INTENSIFIER CONTROLS SCHEMATIC WIRING DIAGRAM (<>0 rt DRAWN .A IV P fT TRACED 0 MOOAC C H T D DATI t - n - i t SCALE REVISED 6 - 1 6 - 3 3 oo ZZ U UI U'* o o' v> w * ui x _j mn o 1o0 n*i*n vs ui t * -i _i -*->->lllfl till U*I U<I H/ c> * z ui < 0 o * ui _ - * Z * Ui ZZ oo o 111- f- *' *1 *1 oX z3 2_ OO * J -I a S * >- >- , , o *" u O ',,_ l-l- _j ->I *M W to vt u o -- UI 4 3o M 2 X *Ui*_J- * SSS2>-u, uzU. Xuu.ko^VS-tIoV-hooi oM 5>uwu< tf) Vi H * oxKJ tI^--/-IluOlliEO. 05,, 5 0t: > 10 t ooM5" tt tt o c ' I- I-- Z tc z z ; ui * > oo2z"* !"< Z:cu 5- OOI-W-,, <auQ-n. * 2 w. ZSCUM J >> M VI DESIGN REPORT CHARGE POLYETHYLENE UNIT, 'PLANT CA PART IV, POWER OIL SYSTEM WP-663B-------------------------------- 1 of'l Jan. 15, 1953 Change No. 1 (A) in right hand margin indicates an addition, (R) indicates a revision EQUIPMENT LIST 6038E-U61 - OVERHEAD CRANE Change Property No. of Crane to CA-6550-8. (R) The following pages are attacted and should be inserted in the subject Design Report; p. 100 125# Hydraulic Oil Specifications revised l/Hi/53. p. 102 300# Hydraulic Oil Specifications revised l/lii/53. p. 10li 2000# Hydraulic Oil Specifications revised l/lii/53. By FFC Approved RAP r 017361 lESIiN ROTBT CHAH3B ytLIETHIIZHE TNIT - PLANT.01 tUtt IV - P00E8 0IL SISTEM IP-0031 Sheet 1 of 1 April 1, 1953 Change No* 2 Please find attached, pages 100, 102, and ltU revised April 1, 1953 "which are te he inserted in the report* BT FTC APffiOVED HAP am 017364 DESIGF HEPCET CHANGE POLTETHYIEHE TWIT - PUNT CA PART IV - POWER OIL SYSTEM WP-^038 1 of 1 May 8, 1953 Formal Change No* 3 (A) in right hand margin Indicates an addition, (R) indicates a revision* Reference Drawing H3B*R10UU (Revised 5-7-53, attached)* EQUIPMENT LIST ^Q38E4i21U THRU -125U - OIL FILTERS Five (5) filters with the following specifications: p. 13 (A) Cuno Engineering Corporation Anto-Klean No* AK-232, Type EGF-2 Material - Standard Element: - Material - Stainless Steel Length - 6* Spacing - 0*012* Connections - 2" ASA 125 psi flanges inlet and outlet* Locations and property numbers follow: Item No* 6038E-L21U 6038E-L22U 6038E-L23U 6038E-U2UU 6038E-L25U Location HHH-Ull HHH-U12 HHH-U13 HHH-UlU HHH-U15 Property No* CA-6331-52 CA-6311-53 CA-6311-5U CA-6311-55 CA-6311-56 017365 l/i,086 <1*087 iAt068 t/(i089 tA096 i/U097 /U098 / U099 /Ulo6 ll07 vb HHH-Ull HHH-iOl HHH-U12 HHH-142 HHH403 HHH-U13 HHH-UlU HHH-UlU HHH-id.5 HHH405 Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff VALVE LIST 3/U" 3/U* 3/U* 3/1*3/1*" 3/U* 3/U" 3/U" 3/U* 3/U* C&CCC No* 1 P* U7 C&CCC No* 1 P* U7 C&CCC No* 1 P. U7 C&CCC No. 1 P. U7 C&CCC No. 1 P* US C&CCC No* 1 P* U8 C&CCC No. 1 P* U8 C&CCC No* 1 P* U8 C&CCC No* 1 P* U8 C&CCC No* 1 P* U8 By FFC Avrrrrm** (R) (R) (R) (R) (R) (R) (R) (R) (R) (R) DESIGN REPORT CHANGE POLYETHYLENE UNIT - PLANT CA PART IV - POWER OIL SYSTEM WP-6038 1 of 2 June 16, 1953 Formal Change No. h (A) in right hand margin indicates an addition, (R) indicates a revision. Reference Drawing H3B-R10kh (revised 6-16-53, attached). Attachments: Table of Contents, Page 87 and 88 - Specifications for 6038E-UL1 thru -U50 Revised 12-9-52. Page 108 - Revised 6-16-53. Page 109 - Revised 6-16-53. Page 113 - SK-56U58 (to replace SK-50889, 50889 if* voided). Page HU - SK-50890 (revised 6-16-53) EQUIPMENT LIST 6038E-li2lL - ALARM HORN p. 12 (R) Actuated by Items 6038E-L21J and R thru -U25J and R and 6037E-358 and 359. 6038E-U97 - OIL PURIFIER Property No. Purifier - CA-6311-57 Pump - CA-6306-238 Motor - CA-6213-329 p. 21 (A) One (l) oil purifier to be used for purification of the oil in any of the five hydraulic oil systems. Purifier to be as follows: Manufacturer - Honan-Crane Corporation Service - Purification of Esstic 55 hydraulic oil at 115F Model - 2036M8-AP equipped with insulation but without heaters. Pump - 5 gpm pump with uUO volt, 3 phase, 60 cycle motor for Class I Group D service to be furnished. Pump to be provided with relief valve and to be self-priming and suitable for a negative suction of 10 feet. Dolly - 28" x UO" dolly with rubber tires and drawbar with handle shall be provided to mount purifier, pump and motor. Cartridges - Cranite filled. Extra cartridges - Provide six (6) sets (of 8 cartridges each) to be used as spares. 017366 DESIGN REPORT CHANGE POLYETHYLENE UNIT - PLANT CA PART IV - POWER OIL SYSTEM VP-6036 VALVE LIST 1*31*1 thru 1*31*5 - CANCEL l*35l thru 1*355 - GAN3EL 1*361 1*362 HHH-1*1*1 HHH-LL2 Shutoff Shutoff 1" 1 1" 1 1*363 1*361* HHH-1*1*3 HHH-l*i*l* Shutoff Shutoff 1" 1 1" 1 1*365 hhh-1*1*5 Shutoff 1" 1 2 of 2 June 16, 1953 Formal Change No. 1* P. 59 P. 59 P 60 p. 60 p. 60 p. 60 p. 60 (R) (R) (R) (R) (R) (R) (R) By FFC Approved RAP vb 017367 DESIGN REPORT CHANGE KgvETHTLENE UNIT - PLANT CA PART IV - POWER OIL SYSTEM WP-6038 Sheet 1 of 1 August 20, 1953 Formal Change No. 5 (A) in right-hand margin indicates an addition, (R) indicates a revision. Reference Drawings H3B-R10l*l*-3 (revised 8-19-53, attached) Attachment: p. 105A - Valve and Piping Specification No. 96 EQUIHIENT LIST / {/o38E-1*1*1B thru -1*50B - RELIEF VALVES (A) p. 15 Ten (10) relief valves as follows: Lunkenheimer - Fig. No. 658 Size 1/2" Set at lT"psi Install in lines MWW-1*01 thru -1*05 inside shutoff valves to coolers 6038&-i*i*l thru -1*50 respectively. LINE LIST 0-1736 ^AA-1*02 - Change spec to 96. 7CA^1*06 - Change spec to 96. - Change spec to 96. ''1*366 1*367 ^1*368 1*369 1*370 1*371 1*372 *373 -1*371* *'-'1*375 WWIWMjOl WrtWW-UOl WWWB-1*02 WWWW-1*02 WWWW-1*03 1MWW*03 FflWW-liOli WiK-hOh mm-hos mm-hos Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff Shutoff VALVE LIST 1/2" 1/2" 1/2* 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" 1/2" ^X1 1 1 1 1 1 1 1 1 1 (B) p. 29 (R) p. 29 <R) p. 29 (A) p. 60 (A) p. 60 (A) p. 60 (A) p. 60 (A) p. 60 (A) p. 60 (A) p. 60 (A) p. 60 (A) p. 60 (A) p. 60 It Bv vw* DESIGN REPCRT CHANGE POLTETHIINE UNIT - PLANT CA PART IV - POWER OIL SYSTEM WP-6036 Sheet l.of 1 October 19, 1953 Formal Change No. 6 (A) in right hand margin indicates an addition, (R) indicates a revision. Parts revised or wanted emphasized are underlined. Reference Drawing H3B-R101A (Not issued at this time). EQUIPMENT LIST J 603S5-U01J THRU -UlOJ - THERMOCOUPIZ ASSEMBLIES (R) p. 8 Correct the drawing number for the separable socket from A3E-El51-Ji type 1 to A3E-lgl-9 type 1. 6038E-h63A - PRESSURE INDICATOR RECEIVER Property too. CA-6332A92 (R) P. 17 (Note change in title.) Change specifications to read as follows: v Type - Pressure Indicator Receiver 7 6038E-i*63A-l - FLOW TRANSMITTER Property No. CA-6332^2ig Range Manometer Material, body element Connections Manufacturer 0 to 50 inches of water Dry type for 750 psi WP Steel Z-nickel lA inch NPT The Faxboro C 01153any (A) p. 18 Install with a gas blowback. Connect to receiver 6038EA63A. Changed by: RGZ Approved by: RAP 017369 ^ DESIGN REPORT CHANGE POLYETHYLENE UNIT - PIANT CA PART IV - POWER OIL SYSTEM WP-6O3B * Sheet 1 of 1 January 195^ Formal Change No. 6 (A) In right hand margin indicates an addition (R) indicates a revision. Parts revised or wanted emphasized are underlined. Reference Drawing H3B-R1044 (Not issued at this time). Attachments: Pages 17 and 18 EQUIPMENT LIST 6038B-40U THRU -4lOJ - THERMOCOUPLE ASSEMBLIES (R) p. 8 Change drawing number for the separable socket from A3E-E151-^> type 1 to A3E-E151-9, type 1. v'' HH-404 Change spec, to 12. LINE LIST (R) p. 29 Changed by: RGZ Approved by: RAP /am 017370 v tn - DESIGN REPORT CHARGE POLYETHYLENE UNIT - PLANT CA-510 PART IV - POWER OIL SYSTEM WP-603B Sheet 1 of 2 May 12, 1954 Formal Change No. 8 IhiB change covers Informal Design Report Changes Nos. 5 and 6. (A) In right hand margin Indicates an addition, (R) Indicates a revision. Parts revised or wanted enphasized are underlined. Attachments: Page6 19, 19A, 21, 29, 30, 6l revised 5-12-54 Pages 94a, 94b - added 5-12-54 Page 100 - p. 2 of 125# Hydraulic Oil Specs. - revised 4-6-54 Page 102 - p. 2 of 300# Hydraulic Oil Specs. - revised 4-6-54 Page 104 - p. 2 of 2000# hydraulic Oil Specs. - revised 4-6-54. equipment LIST </ 6038E-441B THRU -450B - RELIEF VALVES (r) p. 15 Change set pressure to 25. Psi. S 6038E-462B - PRESSURE GAUGE (R) p. 16 Change range to 0-100. / 6038E-462C - PRESSURE REDUCING REGULATOR (r) p. 16 Cancel. y 6038E-462D - RELIEF VALVE (r) p. 16 Change set pressure to 0 psi. 1/ 6038E-463B - PRESSURE GAUGE (r) p. 18 Change range to 0-100. *y 6038E-463C - RELIEF VALVE Change set pressure to 0 psi. ^ 6038E-463D - PRESSURE REDUCING REGULATOR (r) p. 18 (r) p. 18 Cancel. 017371 DESIGN REPORT CHARGE POLYETHYLENE UNIT - PLANT CA-510 PART IV - POWER OIL SYSTEM WP-6o3fe LINE LIST y kk-koG and -1+07 - Cancel. HH-492 - Change spec, to read: 12, 54 VALVE LIST ^ 4554 - Cancel. ^ 4555 - Cancel. 4556 - Change location to: PP-409. 4567 - Cancel. 4568 - Cancel. 4643 - Change location to: PP-410. 4645 - Change location to: PP-409 Sheet 2 of 2 May 12, 1954 Formal Change Ho. 6 (R) p. 29 (R) p. 3^ (R) p. (R) P* (R) P. (R) P. (R) P. (R) P- \^ r\J 'S ' 8> 80 80 Changed by: FFC Approved by: RAP 017372 DESIGN REPORT 930-6039 DATA - NOT A FULL REPORT 017373 TO: FROM: OFFICE M3MO ERCWN & ROOT, INC Mr. Ed Haas A. J. Huddleston DATE March 1. 195A 017374 Sheet 1 of 2 July 18, 1953 WP-6039 SPECIFICATION FOR BOO? ETHATTST AND SUPPLY AIR FANS ITEMS 60395-100 THRU lQAg 6039E-110 THRU 11L. SERVICES Pans 6039E-100 through 104. to supply Tent air to Product Roam 110; 6039E-110 through 113 to exhaust air from Control Room 108; 6039E-114 to supply air to Electrical Control Room 101. CONSTRUCTION; Pans shall be of the low type roof supply and exhaust units, equipped with removable weather-proof hood, hinged "for access to fan motor and drives from roof. Pan units shall be rigidly braced and shall be constructed of best quality galvanized sheet steel having minimum gauge thickness, as follows*. TOP SIDES Item 6039E-100 thru 104 Item 6039E-110 thru 113 Item 6039E-114 18 Ga. 16 Ga. 18 Ga. 18 Ga. 20 Ga. 18 Ga. Galvanized bolts and nuts shall be used throughout. Items 6039E-110 through 113 shall be furnished with automatic tight closing, weighted, louver dampers to open by force of discharge air when fan is energized and to close when fan is de-energized. Pan units shall be furnished with removable bird screens over cutlet and/or inlet and shall be of 1/2n mesh galvanized wire. Fan unit shall be factory coated, both inside and out, with weather protective coating similar and equal to Insul-Mastic 4010 or Nokorode Seal-Kote. Coating shall be a mini mum of 1/16 inch thickness, spray applied in accordance with manufacturers re commendations. The outer surface of fan unit shall have an aluminum gray finish. PAH WHEELSi Pan wheel shall be of the axial flow air foil type, rigidly constructed of a spark-proof nonferrous metal. DRIVES Belt driven units shall have heavy duty, spark-resistant adjustable V-belt drives with integral fan and motor base. Fan bearings shall be self-aligning, heavy duty ball bearing, designed for continuous operation. Motors shall be explosion proof for Class I, Group D, Division 2 installation and shall be of the size and having the electrical characteristics as listed in performance schedule below. MOUNTING Fans shall be suitable for curb mounting on roof. PERFORMANCE; 01737'. The fans as complete units, including hood shall be of the capacities as listed in the following performance schedules Sheet 2 of 2 July 18, 1953 tfP-6039 ITEM HO. CAPACITY C.F.M. MOTCB HoPc MOTCB . R.P.M. MIH. EIECTF TO PAN. DRIVE CHAR. DIAM. DUTY 6039E-100^ 15000/7500 6039E-101 n 6039E-102^ n 6039E-10X 6039E-1Q4 n n < n n B 6039E-U0^ 6039E-111^ 65n75^ 1/2 n 6039E-112^/ B n 6039E-113 6039E-H4X It 3850 . \1 )V2 1800/900 n n n ft 1750 n it tt 1140 Belt 440/3/60 n It n 11 nn tt 11 it 11 nn nn tt n Direct n 36" Supply tt n nn n it " ^ ti 30" Exhaust nM n It n tt 22" Supply ALTERNATE? Pan supplier shall quote as an alternate, the furnishing of Items 6039E-100 through 104 as direct drive fan units having the capacities in C.F.M# as listed in performance schedule above* GUARANTEES See attached sheet for details concerning guarantee, drawing distribution, inspection and service0 017376 Sheet 1 of 1 July 18, 1953 WP-6039 SPECIFICATION FCR ROOF VENTILATING SETS ITEMS 6Q39E-115. 116. 117 SERVICES Fans to be located on roof of product area and are to supply ventilation air to area belov product room 110 and electrical control room 101, CONSTRUCTIONS Fans shall be self-contained packaged S.W.S.I., counter-clock vise, T.H.D. ventilating units, consisting of centrifugal fan, weather-proof housing and hood, motor and spark-resistant adjustable V-belt drive. Fans shall have nonferrous metal spark-proof wheel, inlet cone and inlet ring. Unit shall be similar and equal to utility sets as manufactured by Sturtevant, American Blower and Trane Company. Unit shall have self-aligning bearings equipped with bronze bushings. Fan unit shall be factory coated, both inside and out, with weather protective coating similar and equal to Insul-Mastic 4010 or Nokorode Seal-Kote. Coating shall be a 0f 1/16 inch thickness, spray applied in accordance with manufacturers recommendations. The outer surface of fan unit shall have an aiiiwrirnmi gray finish. MOTCBS s Fan motors shall be 1 H.P., 1750 R.P.M. for 440 volt, 3-phase, 60 c^cle electrical service. They shall be explosion proof, suitable for Class 1, Group D, Division 2 installation, FAN PERFORMANCE; Units shall deliver 3,060 CFM each against total static pressure of 5/8" W.Go Minimum fan wheel size shall be 16" diameter. GUARANTEE; See attached sheet for details concerning guarantee, drawing distribution, inspection and service. 017377 Sheet 1 of 1 July 18, 1953 HP-6039 SPECIFICATIONS FOR UTILITY TEST SETS ITBfrE 6039E - 118. 119 & 120 SERVICES Fans to ventilate vacuum cleaning roan 103, toilet and janitor rooms 104 and 105, and space belev office 107. CONSTRUCTIONS Fans shall be self-contained packaged ventilating units, consisting of centrifugal fan, housing and motors. Fans shall have spark-proof vheels of nonferrous metal and nonferrous inlet cone. Units shall be direct driven and shall be similar and equal to utility sets as manufactured by Sturtevant, American Blower and Trane Company. MOTORSs Fan motors shall be of size as indicated in performance schedule below and shall be explosion proof suitable for Class I, Group 0, Division 2 installa tions. PERFORMANCES Vent sets shall be quiet in operation and have operating characteristics as listed below. FAN HO. C TOTAL STATIC PRESS "W,,G. 6039E-118 / 430 / 1/8" 6039B-119 / 400 6039E-12Q- 900 1/4" 1/4"/ MIN. MOTOR H.P. 1/6/ 1/6/ 1/4 MOTOR ELEC. R.P.M. SERV. MIN. WHEEL DIAM. 1725 110/1/60 6 1725 110/1/60 6 860 110/1/60 9 GUARANTEES See attached sheet for details concerning guarantee, drawing distribution in spection and service. 017378 PROJECT REACTION & EXTRUSION BUILDING NO. 102 POLYETHYLENE UNIT SEAORIFT PUNT PROJECT /40-E PLANT C V. 0. HO. VP-6039 ACCOUNT DESCRIPTION 2 CONCRETE SUBSTRUCT'BEt All concrete below elevation of firet or grade tine floor. Ineludea slab at finiah grade line. Includes walla of reaction cells below grade line. 5 CONCRETE SUPERSTRUCTURE* Allconcrete above elevation of grade line floor* 6 SPECIAL FLOORING! 9 STRUCTURAL STEELi Allstructural steely including interior & exterior stairs, hand rails, ladders, atair treads, thresholds, toe plates, walkways, platforaa, skylights, hatch fraaing, steel doors and steel sash, door & saah steel linteli, plate and grating floors. Includes sand blasting if required. Also includes labor only in painting of a 11 steel. 10 VALLS-EXTERI ORi AlI exterior walla, except poured reinforced concrete walla. Include* sills, sash, door frases, easing & doors other than steel. Includes glazing, plastering, coping & ornasental trio. 11 FIRE PROOFING* Tile, gypsua, concrete, and , plastering, when applied for fireproofing / purposes only. ~ OPENED* I2-3U3I ISSUED! S-U-53 ENGINEERING! BAR CONSTRUCTION! BAR N. 0. NO. VP-6039 PUNT CA SHEET I of 3 PROJECT REACTION i EXTRUSION BUILDING NO. 102 POLYETHYLENE UNIT SEADRIFT PUNT PROJECT 140-E PUNT CA W. 0. NO. MP-&033 ACCOUNT 20 26 DESCRIPTION WALLS-INTER I OR PARTITION! CoaparabI construct ion & aatarials to that covered undar Account 10* - PAINTINGt Walla, callings, floors, sash A doors. Includes material only for structural staal, equipaent, or piping. Labor to ba charged to specific accounts covering staal, equipaent, or piping to ba painted. 35 ROOPi Built up or other type roof. DOES NOT include ventilators. Includes gutters, flashing, down spouts & scuppers. 39 PLUMBING! All pluabing service for building, including wash fountains, water coolers, toilet and shower partitions. ISEWERSe^-ATT process and sanitary sewer lines tojeslifioi ea. MANHOLS-SfWERl *3 BUILDING LIGHTINGt Includes telephone conduit & lead wire. 44 POWER FOR BUILDINGt Includes controlIsra for aotora on unit heaters, ouap pumps, ventilating fans or other power units for building use only. OPENED! 12-31-51 ISSUED! 4-14-53 ENGINEERING! 6&R CONSTRUCTION! BAR W. 0. NO. WP-4033 PUNT CA SHEET 2 of 3 -J* / 017380 PROJECT REACTION A EXTRUSION BUILOINO NO. 102 POLYETHYLENE UNIT 8EADRIFT PUNT PROJECT 140-E PUNT CA V. 0. NO. WP-6033 ACCOUNT *5 46 50 56 64 66 153 155 153 160 162 DESCRIPTION HEATING A VENTIUTIONi include* piping, hatting unit*, ventilating fan* A blower*, duct* A louvre*. AIR CONDITIONING* All sateriala A Installation incident to air conditioning. FIRE PROTECTION* Sprinkler eyatsr, CO2 flooding aystss, ho** rack*, ho*e reel*, engine*, foaaite equipment and fire line piping in building. FILL* Include* grading of outside fill. FINAL JOB CLEANUP* NI8CELUNE0US OPERATING EQUIPMENT* Office furniture *nd equipment, auxiliary operating squipsent, safety equipment, locker*. ' PAVEMENTS* Concrete tec*** drives A sidewalks. DUCTS A CHUTES* Do** NOT include heating, ventilating and air conditioning duct*. __ . / LIGHT FEEDERS* Fro* substation to lighting panel. Include* lighting panel. FIRE AURM 8YSTEM* INSTRUMENTS* Include* only those instruaents installed for building us* only. OPENEDi 12-31-51 ISSUED1 4-14-53 ENGINEERING* BAR CONSTRUCTION! BAR W. 0. NO. VP-6033 PUNT CA SHEET 3 of 3 PROiECT REACT I ON A EXTRUSION BUI L0IN6 JO. 102 POLYETHYLENE WIT SEAMIFT PUNT . PROJECT NO. 40-E PUNT CA W. 0. NO. HP-COM ACCOUNT DESCRIPTION AOOENOUN NO. I TO ACCOUNT BREAKDOWN DATED 4-14-53 PLEASE CANCEL THE FOLLOWING ACCOUNTSI 40 SEWERS* 41 NANHOLESi OPENED* 12-31-51 ISSUED* 4-14-52 AOOENOUN NO. I 5-6-53 ENGINEERING* BAR CONSTRUCTION* BAR N. 0. NO. WP-6033 PUNT CA SHEET I of I 017382 TOl LOCATION. TITLE a. a. 1^039 WORK ORDER MX BUDGET CLASSIFICATION NO. REQUEST Na THE FOLLOWING WORK IS TO IE DONE MO CHARGES TO THIS ORDER DISTRIBUTION OF CHARG1 COPIES TO: CS 4821 authorized by ,CTUAL C0ST DEC 311051;;; DATE OPENED_____________ _ DATE COMPLETED______________ DATE CLEARED______________ H. F. THOMPSON LOCATION REQUEST NO. TITLE carbide and carbon chemicals company A DIVISION or UNION CARBIDE AND CARBON CORPORATION ENGINEERING DEPARTMENT ESTIMATE OF COST PLANT WORK ORDER NO. >SQ?9 BUDGET DESCRIPTION LABOR MATERIAL TOTAL fill la a vlll to iaitonatioft la mllalU. APPROVED 017384 DATE TOTAL ^B^R, EXPENSE ya % or LABOR BUS*TOTAL ENGINEERING ] % OR SUB-TOTAL SUB-TOTAL CONTINGENCIES Ifl % OR SUB-TOTAL _____________ liMM fllMVW^ GlVA 1 1-- V* T- T-J ""DTt>TAl-----------------------BOOB ESTIMATED BY _ . . .--------- DATE fltUIUUf CHECKED BY DATE U*LfaH HECT 1 F I .> _ ' is!M ' VP Ho.. ifSBLjexet Dvg na. A2gfeSZ.3 LTrtXAA. -1226545. J236SUL Filters for Alar iBiujH*- aw v' ' 'ife-A 1 ' CARBIDE V&AHBGH CEZXXCAZB .CO* ^V X fi * ` -6XADBIFT PLATO811,1 of Material Ho. " ' . ' ' 4 ' Shoot 1 of 1 - Prepared tr AIK - ato Cbeoked by Sfi_ Dot* - Reaction Bnlldlng tiorT Ho. Soto To bo 3 Senate Purchased byt Plold Req'd. Unit Description 1 Finish and install rcnlaoaohla trroo air Aoct. Bay* 15 */ 0 filtaro in ai wnlltlnlBff lta mm lAmtmA 5 bolou. If Pllt-r. ahall a *!** ftta, fllt-rt* 5 6 filters ss nanafaotursd tv fmano rmnlnii 7 Fiberglass Ccrp. Prloo Anoint . * R 22 16" X 200 x 2* Unit 60-WR-121 lo 11 _12. n _ik ___11 _ Jl _1L Ifl | 20 21 i ! i1 ___________________________________________________ I_____ 1i 1! 1 1 | it j .21 017385 9U Ta LOCATION. TITLE ; - WORK: ORDER AUTHORIZATION ENGINEERING DEPARTMENT CARBIDE & CABBnW r.HEMTCAT.S COMPANY COMPANY NAM MR. J. H. WARE WORK ORDER NO. I16OO CLINTON DRIVE PROJECT wnwggTTrtKKwrinifBiM NO. WP-6039 JiQzfi___ HOUSTON. TEXAS REQUEST NO__ . THE fetlBWIM WORK l TO BE POKE AND CMMII TO THU PAPER REACTION AND EXTRUSION BUILDING POLYETHYLENE UNIT SEADRIFT PLANT DISTRIBUTION OF CHARGES: ACCOUNT ITEM PCS. DESCRIPTION ACCOUNT ITEM PCS. DESCRIPTION 2 CONCRETE SUBSTRUCTURE h$ HEATING & VENTILATION 5 CONCRETE SUPERSTRUCTURE I16 AIR CONDITIONING 6 SPECIAL FLOORING 50 FIRE PROTECTION 9 STRUCTURAL STEEL 56 FILL 10 WALLS-EXTERIOR 6U FINAL JOB CLEANUP 20 WALLS-INTERIOR PARTITION 66 MISC. OPERATING EQUIP, 26 PAINTING 153 PAVEMENTS 35 ROOF 159 LIGHT FEEDERS 39 PLUMBING 160 FIRE ALARM SYSTEM 2i3 BUILDING LIGHTING Wi POWER FOR BUILDING NOTE: THIS WORK WILL BE PERFORMED BY BROWN & ROOT, INC. ORIGINAL AUTHORIZATION 12/31/51 750,000.00 DECREASED AUTHORIZATION 93,900.00 SEP 2 2 1953-- TOTAL AUTHORIZATION 656,100.00 COPIES TO: Mr. H. E. Thompson Mr. J. T. Donahoe Mr. ff, D. Kinsey Dr. C. M. Blair Mr. S, V. Clarke Mr. W, S. Brackett Mr. R, N. Shepard Mr. C, B. Mastin'^ Mr. F, J. Crumbaker CS 4821 AUTHORIZED BV 017386 AMOUNT AUTHORIZED 656.ioo.oo ACTUAL COST. SEE ABOVE DATE OPENED, DATE COMPLETED DATE CLEARED THOMPSON CARBIDE AND CARBON CHEMICALS COMPANY * ENGINEERING DEPARTMENT ESTIMATE OF COST LOCATION REQUEST NO. TITLE SEADRIFT, TEXAS 510-39A WORK ORDER NO. VJP-6039 REACTION AND EXTRUSION BUILDING POLYETHYLENE UNIT SEADRIFT PLANT PLANT 510 | -udoet PROJECT NO. 40-E Account ITEM PCS. DESCRIPTION 2 5 6 9 10 20 26 35 39 43 44 45 46 5o 56 61* 66 153 159 160 CONCRETE SUBSTRUCTURE CONCRETE SUPERSTRUCTURE SPECIAL FLOORING STRUCTURAL STEEL WALLS-EXTERIOR WALLS-INTERIOR PARTITION PAINTING ROOF PLUMBING BUILDING LIGHTING POWER FOR BUILDING HEATING & VENTILATION AIR CONDITIONING FIRE PROTECTION FILL FINAL JOB CLEANUP MISCELLANEOUS OPERATING EQUIPMENT PAVEMENTS LIGHT FEEDERS FIRE ALARM SYSTEM LABOR MATERIAL TOTAL 26,850 74,150 320 26,730 1,170 980 1,000 5,320 9U0 8,670 2,000 3,300 250 1*90 4o ii,690 200 3,400 1,000 600 42,890 69,740 47,870 122,020 400 720 111,710 138,440 2,800 3,970 740 1,720 6,700 7,700 7,790 13,110 1,560 2,500 12,400 21,070 5,500 7,500 19,280 22,580 .2,220 2,470 11,430 11,920 100 140 3,130 7,820 1,290 1,490 5,100 8,500 3,160 4,160 830 1,430 017387 1 CARBIDE AND CARBON CHEMICALS COMPANY LOCATION ENGINEERING DEPARTMENT SEADRIFT, TEXAS ESTIMATE OF COST H< *_____________PLANT 510 REQUEST NO. 510-39A WORK ORDER NO. WP-6039 UDorr PROJECT NO. liO-E TITLE REACTION AND EXTRUSION BUILDING POLYETHYLENE UNIT SEADRIFT PLANT DESCRIPTION LABOR MATERIAL TOTAL ORIGINAL AUTHORIZATION 12/31/51 750,000.00 DECREASED AUTHORIZATION 2 2 1953 93,90Q.0( TOTAL AUTHORIZATION , . (656 100 0 NOTE: THIS WORK WILL BE PERFORMED BY BROWN & ROOT, INC. APPROVED DATE total 162.100 266.900 ^9.000 KXPKNSI ENGINEER INQ % OF LASOR ___ y/ijw SUB'TOTAL 5L6.300 6 % OP SUB-TOTAL 32.800 CONTINGENCIES r BB SUB.YOTAL 10 3 % OP BUB-TOTAL GRAND TOTAL 579.100 57,900 iv,io(j 656.100 ESTIMATED SY CHECKED BY B&R ____ __bate 7-15-53_________ DATE SHEET OP 017388