Document DGBmN9KmbzVLJ9qRx52LomQaa
G
Snell
Font D. Snail, Inc. General Laboratoriea Hanover Road Florham Park New Jerter 07932
(201) 377-8700
December 26, 1973
Mr. William B, Papageorge Manager, Product Acceptability Monsanto Industrial Chemicals Company 800 N. Lindbergh Boulevard St. Louis, Missouri 63166
Dear Bill:
Thanlc you for your help in regard to defining PCB practices In our study for BPA under Contract No. 68-01-2106.
Attached you will find a draft copy of our report entitled, "Market Input/Output Profile, Process Technology Assessment And Entry Into The Environment of Polychlorinated Biphenyls (FCBs)".
Monsanto is the source of much of the information assembled. Please review the report and comment at your earliest convenience. We are grateful for your continued cooperation.
Stephen F. Nagy Project Manager
Enclosure
dt
cc: Tom Xopp (EPA) H.K. Weiss
w*7 Inc4.
A SubttdPWV of
8002'ALLEN a HAMILTON Inc.
HONS 209446
O
Snell
Fcmar D, Snslt. Inc. Gananl laboratories Hanover Road Florham Park New Jeney 07932
(201) 377-8700
December 20, 1973
Mr. Thomas Kopp, Project Officer Environmental Protection Agency 401 M Street. S.W. Room 707-A, East Tower Washington, D. C. 20460
Reference:
Contract No. 63-01-2106. Task Order No. 2, Market Input/Output Profile, Process Technology Assessment, and Entry into the Environment of Polychlorinated Bi phenyls (PCBs)
Dear Tom'.
We are pleased to be of service to you in your environmental management activities related to PCBs.
There is need for an integrated definition of the movement of this com modity through our economy and its entry into the environment.
Our report pursuant to the Taak Order is attached. The detailed findings of the study are presented in separate report sections dealing with:
. production quantities; . the PCB production process; . end-use market data and manufacturing
processs; , entry of PCBs into the environment and . control steps .
A Subsidiary ol 8002 1 ALLEN a HAMILTON Inc
HONS 209447
Mr. Thomas Kopp. Project Officer Environmental Protection Agency December 20. 1373 Page Two
Specific recommendations have been developed for related further focused study and some environmental management alternatives have been defined.
We look forward to providing continued assistance to EPA in defining control criteria for PCBs.
V ery truly yours.
Stephen F. Nagy Project Manager
dtI
FOSTER D . SNELL.Inc.
I CiT* 0 Snell, Inc
HONS 209448
DRAFT "This Report Is Not Meant To Be An Exhaustive Study.
It Was Prepared In Response To A Specific Inquiry For Rapid Retrieval And Assembly Of Information"
MARKET INPUT/OUTPUT PROFILE, PROCESS TECHNOLOGY ASSESSMENT AND ENTRY INTO THE
ENVIRONMENT OF POLYCHLORINATED BIPHENYLS (PCBs)
TASK ORDER NUMBER 1
PREPARED BY FOSTER D . SNELL . INC , FOR UNITED STATES
ENVIRONMENTAL PROTECTION AGENCY UNDER CONTRACT NUMBER 68-01-210G
DECEMBER 197 3
HONS 209449
TABLE OF CONTENTS
' SECTION I
FINDINGS AND CONCLUSIONS
'
SECTION II
RECOMMENDATIONS
SECTION III
INTRODUCTION
SECTION IV
PRODUCTION QUANTITIES
EXHIBIT I
Composition of Different Liquid PCB Products
EXHIBIT II
PCB Manufacture and Sales Monsanto Industrial Chemicals Co.
EXHIBIT III
End-Used of Aroclors
SECTION V
MANUFACTURING PROCESSES
EXHIBIT IV
Patent Digest
EXHIBIT V
Process Flow and Environmental Controls at Monsanto's Sauget Plant
EXHIBIT VI
Shipping of Aroclor Plasticizers
EXHIBIT VII
Example of Current Aroclor Labeling Practice
EXHIBIT VIII
Excerpts From NEMA's Proposed Environmental Controls
EXHIBIT IX '
Disposal Services Listed in Section 4 of NEMA'S Official
Standards Proposal
2 I-i Ii-i III-I rV-1 IV-11
V-l V-6
HONS 209450
TABLE OF CONTENTS (continued)
SECTION VI
MANUFACTURING PROCESSES IN WHICH PCBs ARE USED
EXHIBIT X
Historical Distribution of PCB Types and End-Use
`
Page VI-1
VI-17
EXHIBIT XI EXHIBIT XII EXHIBIT XIII
EXHIBIT XIV EXHIBIT XV EXHIBIT XVI
PCB Use in the Electrical Industry
Transformer Trends (1967-1974)
Fluorescent Lamp Ballast Shipments (1963-1972)
PCB Losses in Capacitor Manufacture
Transformer Imports
Excerpts From Broadhurst On PCB Technology in Open Systems and Heat Transfer
EXHIBIT XVII
PCB Levels Associated With Various Products/Processes
SECTION VII
THE ENTRY OF PCBs INTO THE ENVIRONMENT AND MANAGEMENT STEPS
VB-1
EXHIBIT XVIII EXHIBIT XIX
EXHIBIT XX SECTION VIII
PCB Service Life Functions
Example of the Use of PCB Service Life Functions: Estimate of Capacitor PCBs In-Service
Historical Pattern of PCB Channels To The Environment
BIBLIOGRAPHY
VII-12 VI1I-1
HONS 209451
ABSTRACT
The Office of Toxic Substances of the United States Environmental Protection Agency issued a task order to Foster D. Snell, Inc. under Contract No. 68-01-2106 to prepare a broad report on a rapid response basis on the "Market Input/Output Profile. Process Technology Assessment And Entry Into The Environment Of Polychlorinated Biphenyls (PCBs)".
The study scope included literature review, patent analysis and strategic interviews.
The Monsanto Industrial Chemicals Company is the sole use producer of PCBs under the "Aroclor" trademark. Production capacity is about 48 million lbs annually. Imports appear to constitute 2% or less of domestic usage.
In recent years the use of PCBs has been voluntarily confined by Monsanto, essentially completely to transformer and capacitor applications. Roughly 500 million lbs. of PCBs are currently in-service, over 95% in transformers and capacitors.
Recommendations include in-depth study of the market, technical and environmental aspects of PCB use in transformers and capacitors. PCB management steps recommended for further evaluation are: banning use of the commodity in non-electrical applications and the granting of exemptions case-by-case; formal sanctioning of the National Standard Guidelines For Handling and Disposal of Capacitor - And Transformer - Grade Askarels Containing Polychlorinated Biphenyls; establishment of an enforcement mechanism that also applies to import controls.
HONS 209452
SECTION I HONS 209453
SECTION I
FINDINGS AND CONCLUSIONS
This section serves as an executive summary of principal findings and conclusions related to PCB market trends, technology and environ mental control patterns and information gaps.
I, PCB PRODUCTS ARE MIXTURES OF VARIOUS HOMOLOGS OF CHLORINATED BIPHENYL
(1) Contaminants And Impurities In The Product Are Determined By The Quality Of The Starting Materials And Process Conditions
(2) The Unique Physical And Chemical Properties Of PCBs Have Made These Substances Technically Attractive In A Variety Of End Uses
(3) PCBs Have Been In Commercial Use In The U.S. Since The 1920s
(4) The Tetrachloro And Lower Chlorobiphenyls Appear Less Persistent In The Environment Than The Higher Chlorobiphenyls
2. THE MONSANTO INDUSTRIAL CHEMICALS COMPANY IS THE SOLE U.S. PRODUCER OF PCBs
3. MONSANTO'S CURRENT APPROXIMATE NAMEPLATE PRODUCTION CAPACITY IS 46 MILLION LBS. PCBs PER YEAR (36)
4 . ANNUAL STATISTICS FOR U.S. PRODUCTION AND SALES OF AROCLORS SHOW MARKED DECREASE CAUSED BY RESTRICTION OF USE TO ELECTRICAL APPLICATIONS SINCE 1971
(1) Monsanto No Longer Sells PCBs For End-Uses Other Than Capacitor And Transformer Insulating Liquids
(2) Domestic Sales Of Aroclors Are Expected To Increase At An Average Annual Rate Of 7.4% Over The Next Five Years
HONS 209454 1-1
5. THE PATTERN OF WORLD COMMERCE IN PCSs INDICATES LOWER FUTURE PRODUCTION AND RESTRICTED USAGE
(1) Import Statistics Indicate That Only About 2% Of PCBs Sold In The U.S. Were Imported In 1971 And About
' l,n In 1972
(2) Imports of PCBs Are Expected To Be Less Than 2% Of Total U.S. Sales During The Next Five Years
(3) During The Period From 1963 Through 1972 Exports Of Aroclors Were 7fl,7 Million Lbs.
(4) Exports of Aroclors Are Expected To Maintain The Same Ratio To U.S- Sales As In The Past Several Years (361 , Or 10-15%
(5) Known Foreign Producers of PCBs Include Czechoslovakia France. Germany. Italy, Japan. Spain, and the U.S.S.R.
(6) World Commerce In PCBs Is Expected To Decrease By About The Same Amount Or More Than In The U.S. Since 1970, And To Be Essentially Confined To Capacitor And Transformer Applications
6. THE MANUFACTURE OF PCBs IS NOT A COMPLEX PROCESS
(I) Currently There Is Onlv One Known Commercial Scale PCB Production Installation In The U.S.. Onerafnd Bv Mnnsantn
(2) Monsanto Has Reported Significant Environmental Controls At This Plant
7. HISTORICALLY. AROCLORS HAVE BEEN SHIPPED IN A FASHION SIMILAR TO ANY OTHER COMMODITY
. Both Monsanto and the National Electrical Manufacturers Association (NEMA) have taken special steps toward environmental controls in future transport of PCBs.
HONS 209455 1-2
8, THERE IS EVIDENCE OF RESEARCH AND DEVELOPMENT ACTIVITY TO CONTROL SPENT PCBs
Envirotech Corporation reported an energy saving method of combusting waste PCBs. In Japan chemical destruction methods have been studied.
9. DURING THE PERIOD FROM 1957 THROUGH 1973 [PROJECTED) . ACCUMULATED U,S. CONSUMPTION OF PCBs WAS ABOUT 775 MILLION LBs., INCLUDING IMPORTS
(1) During The Period From 1957 Through 1973 Approximately 234 Million Lbs. Of PCBs Were Used In ''Open11 Systems And Approximately 541 Million Were Used In "Long Lived Contained" Systems
[2} During The Period From 1957 Through 1971, Approximately 46% Of Aroclors Sold In The U.S, Were The Least Persistent Trlchloro Or Lower Chlorobiphenyls (12)
C3) An Estimate Of The Total Aroclor Used In The U.S. In Electrical Systems Since 1934 Is 752 Million Lbs.
(4) An Estimate Of The Total Aroclor Used In The U.S. In Non-Electrical Systems Since 1934 Is 367 Million Lbs.
(5) An Estimate Of The Reasonable Upper Limit On Total PCB Consumption In The U.S. Since 1934 Is 1.175 Million Lbs., Assuming A 5% Conservative Margin For Imports And Statistical Uncertainty
(6) Before 1971 There Were 10 to 15,000 Direct Purchasers Of Aroclors. While Currently There Are 25-30
. These purchasers ordered Aroclors directly from Monsanto
. Papageorge (36) reported that the order of magnitude of purchasers of Aroclor in 1971 or before in each
' end-use category is as follows:
Heat Transfer Hydraulics Lubricants Misc. Industrial
: ; : :
Transformers and
Capacitors
:
Plasticizer Applications :
2.000 3.000 "few" "several thousand"
40-50 2,000
1-3 HONS 209456
Many of these purchasers were distributors further disbursing PCBs to countless small accounts (36)
Since Monsanto's voluntary restriction of sales and other control actions, there are currently 25-30 direct customers, all in transformer and capacitor applications. These customers use PCBs askarels in the finished products (capacitors and transformers) or'ln the course of servicing.
10. 1973 USE OF PCBs BY THE U.S. ELECTRICAL INDUSTRY 1$ ESTIMATED AT 36 MILLION POUNDS AND IS EXPECTED TO INCREASE TO ABOUT 51 MILLION POUNDS BY 1978
(1) The Average Annual Growth Rate For PCB Use By The Electrical Industry During The 1963-1973 Period Is 4.6% And This Is Expected To Increase To About 7.4% Through 1978
(2) Present Production And Handling Procedures Adopted By Major Transformer And Capacitor Manufacturers (16) Minimize Environmental Contamination (50)
(3) The Capacitor And Transformer Manufacturing Industry Is A Highly Concentrated Industry
. According to the National Electrical Manufacturers Association (16). its member companies have the major share of this market to the utility industry.
- 22 transformer producers - 6 capacitor producers
. According to the Certified Ballasts Manufacturers Association (53) there are only 10 manufacturers of fluorescent lamp ballasts.
(4) .
The Consumer Sector (Principally Electric Utilities) Is Becoming Increasingly Conscious Of The Need To Reduce Environmental Contamination
(5) The Value Of Imported Transformers In 1973 Is Estimated At 50 Million And Is A Small Portion Of Total Transformer Sales
Probably only few imported transformers contain insulating oils due to shipping, handling and economic considerations.
HONS 209457 1-4
. There is indication that probably relatively insignificant numbers of askarel type trans formers are imported.
(6) Near Term Replacement Of PCBs In Most Askarel Electrical Applications Is Technically Not Feasible
11. OPEN SYSTEMS END-USES HAVE ENCOMPASSED A BROAD RANGE OF APPLICATIONS IN WIDELY DISTRIBUTED PRODUCTS AND PROCESSES
(1) The Applicability Of PCBs In Open Systems Is Wide-Ranging
(2) In Most Open Systems Situations The Concentrations Of PCBs Associated With The Product/Process Have Probably Been Low Percentages
(3) During The Next Five Years. Imports Are Expected To Be Essentially The Sole Source Of Fresh PCBs In Open System End-Uses With Investment Casting Accounting For A Major Portion
12. BASED ON A SNELL LIFE CYCLE MODEL. ABOUT 500 MILLION LBS, OF PCBs ARE IN-SERVICE, ESSENTIALLY ALL IN ELECTRICAL APPLICATIONS
(1) Nelson (3B) Estimated That The Equivalent of 80% Of The Annual PCB Usage Was Scrapped In 1970
(2) A Life Cycle Model Developed From Further Evaluation Of Nelson's (3B) Assumptions Regarding The Scrappage Rates Of PCBs. Indicates That The Equivalent Of Only About 26% Of The Annual PCB Usage Was Scrapped In 1970
. The total amount of PCBs in-service through the end of 1973 was estimated using the model. The table below presents in-service estimates by end-use category.
End-Uso
PCB Quantity In-Service Through 1973 (million lbs.)
Transformers Capacitors Heat exchangers Plasticizer applications Hydraulic fluids and lubricants Miscellaneous industrial applications
205 270
11 negligible
9 negligible
Total
495
1-5 HONS 209458
At the end of the next five years only a negligible amount of PCBs will still be in non-electrical service. SIGNIFICANT STEPS HAVE ALREADY BEEN TAKEN TO ENVIRONMENTALLY MANAGE PCBs IN PRODUCTION. CONSUMPTION AND COMMERCE (1) The Monsanto Company, The Sole U.S. Producer. Has Led Environmental Control Of PCBs (2) The Market Statistics Suggest That The Great Majority Of Open System Users Of PCB Have Found Alternatives To This Commodity, But There Has Not Been A Sense of Urgency To Eliminate PCBs Already In Service (3) The Current Buyers Of PCBs For Capacitor And Transformer Insulation Have Taken Formal Steps Toward Environmental Control (4) The Control Of PCBs Already In The Environment Is Not Feasible. Except In Highly Localized Situations (5) Regulatory Action Can Assure Enforcement Of Controlled Use Of PCBs In The Future
1-6 HONS 209459
SECTION II HONS 209460
SECTION II
RECOMMENDATIONS
In this section recommendations are presented related to further work to define the movement of FCBs through the commercial and wastage cycle. Other recommendations address FCB management strategies.
1. IN-DEPTH SURVEY OF THE ELECTRICAL INDUSTRY IS RECOMMENDED
The purpose of the proposed survey is to obtain detailed information of FCB use practices in the electrical industry, which now accounts for essentially all the PCBs consumed in the U.S. There is strong evidence that in the near-term replacement of PCBs in the current electrical uses would pose serious technological as well as institutional problems-
The scope of the proposed survey is to define in-depth
. shipping and handling of PCBs for electrical end-uses
. transformer and capacitor manufacture and use technology
. environmental protection practice
- technical - administrative
. market configurations
- production and distribution of . askarel capacitors and transformers
- use of these
- forecasts of production, distri bution and use
. research and development status
- replacement of PCBs - environmental controls
HONS 209461 II-l
. economic impact of limiting FCB use in the electrical industry with respect to specific management strategies
The proposed survey methods include literature review and telephone and visit survey of individual firms through the coordination of Industry associations.
Without economic impact assessment. the estimated level of effort required is 8-10 man-months over a four month performance period.
HONS 209462 11-2
2. EVALUATION OF SELECTED PCB MANAGEMENT OPTIONS IS RECOMMENDED Study of the following PCB management concepts is recommended: . Formal banning of the sale or purchase of PCBs for non-electrical uses, and the grant ing of exemptions on a case-by-case basis ' . Formal sanctioning of the National Standard Guidelines For Handling and Disposal of Capacitor - And Transformer - Grade Askarels Containing Polychlorinated Biphenyls . Establishing an enforcement mechanism that also applies to importing of PCBs
HONS 209463 11-3
| SECTION III i i
HONS 209464
SECTION 111
INTRODUCTION
In conjunction with its hazardous materials control activities, the Office of Toxic Substances of the United States Environmental Protection Agency (EPA) has issued the second task order to Foster D. Snell, Inc. (Snell) under Contract No. 68-01-2106 to prepare a report on the "Market Input/Output Profile, Process Technology Assessment. And Entry Into The Environment Of Polychlorinated Biphenyls (PCBs)". The report summarizes the findings developed during the six week, rapid response effort to assemble this information from literature review, market research, technology assessment and selective interviewing of industry sources.
1. PURPOSE
There is need for improved definition of the movement of PCBs through the various production/consumption/wastage steps of our complex economy, both in terms of the respective PCB quantities and processes Involved. The purpose of this study is to assimilate existing scattered information pertaining to this for an Integrated definition, and to identify further Information needs.
The study outputs are designed to aid EPA in understanding the historical and current commercial status of PCBs and to provide technical support to decision making regarding the control of these substances.
2. APPROACH AND SCOPE
The rapid response effort to this task order is based upon literature search and review, selective Interviews with industry sources, patent summarization and technology assessment, and market research.
To obtain pertinent references on polychlorinated biphenyls, in addition to the Snell and EPA (Washington) libraries, the following places were visited: The Chemist's Club (N.Y.) , Commerce Department Library (N.Y.) , Custom's Bureau (N.Y.). the Tariff Commission (N.Y,). and the Engineering Society Library (N.Y.). The card catalogs of the libraries were reviewed and the following indices were perused:
Business Periodicals Engineering
II1-1
HONS 209465
. Applied Science and Technology . Funk and Scott . Predicasta . Chemical Marketing Abstracts . Chemical Engineering . Government Reports , Search
The useful citations obtained are contained within the bibliography accompanying the report.
In addition. personal communication was established with the following sources:
. Monsanto Industrial Chemicals Corporation . National Electric Manufacturers Association (NEMA) . Edison Electric Institute (EE1) . Selected transformer and capacitor manufacturers . Other industry sources
.
The cooperation of the Monsanto Industrial Chemicals Company, the sole U.S. producer of PCBs. is acknowledged.
111-2
HONS 209466
SECTION IV HONS 209467
SECTION IV
PRODUCTION QUANTITIES
In this section market statistics are presented regarding the sources of polychlorinated biphenyl (PCB) products.
1. PCB PRODUCTS ARE MIXTURES OF VARIOUS HOMOLOGS OF CHLORINATED BIPHENYL
Whenever aromatic hydrocarbons such as biphenyls are chlorinated, the product is a mixture of compounds, including isomers. The Inter departmental Task Force on PCBs Cl) summarized the composition of the different liquid chlorinated biphenyl products usod predominantly in the U.S., as shown in the first page of Exhibit 1. The second page of the exhibit shows typical percent composition of the materials currently marketed.
Cl) Contaminants And Impurities In The Product Are Determined By The Quality Of The Starting Materials And Process Conditions
Fractionation of samples of some PCBs of foreign manufacture indicated the presence of tetra and pentachlorodibenzofurans and hexa-and heptachloronaphthalenes (l, 20}
Papageorge (36) indicated that, within the limits of detectability. PCBs produced by the Monsanto Industrial Chemicals Company have not been found to contain these impurities.
- Monsanto uses biphenyl feedstock of high purity
- Monsanto neutralizes the reaction mass with lime rather than caustic soda (used in Europe)
IV-l
HONS 209468
(2) The Unique Physical And Chemical Properties Of PCBs Have Made These Substances Technically Attractive In A Variety Of End Uses
. The most important physical properties of PCBs are low vapor pressures (high boiling points). low water solubility, and high dielectric constants. They are miscible with most organic solvents and compatible with many types of polymers. Although some Individual PCB compounds are crystalline, commercial mixtures have been either liquids or resins.
. The chemical properties that make PCBs desirable in dustrial materials are: excellent thermal stability, strong resistance to both acidic and basic hydrolysis, general Inertness and resistance to oxidation.
. Specific data on these properties are summarized in the Encyclopedia of Chemical Technology (11).
(3) PCBs Have Been In Commercial Use In The U.S. Since The 1920s
This represents over 40 years of industrial application.
Early applications of PCBs were primarily as insulating fluid In the electrical industry and as heat transfer fluid (14).
In the early 1960s several new applications were promoted (14) ,
(4) The Tetrachloro And Lower Chlorobiphenyls Appear Less Persistent In The Environment Than The Higher Chloroblphenyls
. Nelson (38) summarizing the findings of several workers found evidence supporting this conclusion.
. Tucker of Monsanto (12) also concluded this and made the following correlation based on the homolog distribution of PCBs sold by the company from 1957 to 1971.
IV-2
HONS 209469
PCB Chlorine Homolog
0 1 2 3 4 5 6 7 8
Percent Homolog in Monsanto U.S.
Sales 1957-1971
0.1 1.3
14.8 29.9 21.9 16.1 10.5
4.2 1.1
Percent Homolog in Laboratory Aged Aroclor 1254, (Similar to PCBs Found in Environmental
Samples)
.1 .1 .5 1 21 48 23 6 Not Detectable
IV-3
HONS 209470
2. THE MONSANTO INDUSTRIAL CHEMICALS COMPANY IS THE SOLE U.S. PRODUCER OF PCBs
There is no evidence in the literature that other companies have produced PCBs domestically in appreciable commercial quantities. There is evidence, however, that PCBs have been imported.
The tradename used by Monsanto for these products is Aroclor. Some principal Industrial purchasers of Aroclors use the product under their own trade names.
1V-4
HONS 209471
3. MONSANTO'S CURRENT APPROXIMATE NAMEPLATE PRODUCTION CAPACITY IS 48 MILLION LBS. PCBs PER YEAR (36)
Until 1971 these materials were produced at two locations.
Plant Location
Anniston. Alabama
Sauget. Illinois (Wm. G. Krummrich Plant)
Capacity (Million lbs.)
48
48
The Alabama plant was dismantled in April, 1971. Nameplate production capacity of the two facilities was approximately 96 million lbs. (36).
The 1973 projected production at the Illinois plant is approximately 43 million lbs. (37). This represents about 90% utilization of capacity.
1V-5
MO NS 209472
4. ANNUAL STATISTICS FOR U.S. PRODUCTION AND SALES OF AROCLORS SHOW MARKED DECREASE IN USAGE CAUSED BY RESTRICTION TO ELECTRICAL APPLICATIONS SINCE 1971
These data, appearing In Exhibit 11, specify Aroclor as well as end-use categories. Export data are also presented.
(1) Monsanto No Longer Sells PCBs For End-Uses Other Than Capacitor And Transformer Insulating Liquids
, This voluntary restriction by the essentially sole source of PCBs for U.S. consumption was motivated by appreci ation of the difficulties involved in imposing workable environmental controls in the other end-use categories (12, 36, 37).
. Sales for heat transfer were phased out in 1972 while sales for other non-electric uses were discontinued in 1971.
(2) Specific End-Uses. Including Those For Which Sales Were Phased Out By Monsanto Are Correlated With Aroclor Type In Exhibit 111
(3) Domestic Sales Of Aroclors Are Expected To Increase At An Average Annual Rate Of 7.4% Over The Next Five Years
. Papageorge (36) indicated that for planning purposes Monsanto preliminarily expects a 6% annual growth rate in sales, all for capacitor and transformer applications.
. Growth in Aroclor sales will depend on the outlook for askarel (PCB) type capacitors and transformers (36).
. Selective interviews with industry sources and correlations with Predicast projections (42) indicate the following annual growth projections through 1978
- askarel use in capacitors: - - askarel use in transformers:
- PCBs:
6\ 10 %
7.4 %
See Section VI for in-depth discussion.
IV-6
HONS 209473
5. THE PATTERN OF WORLD COMMERCE IN PCBs INDICATES LOWER FUTURE PRODUCTION AND RESTRICTED USAGE
(1) Import Statistics Indicate That Only About 2% of PCBs
Sold In The U.S. Were Imported In 1971 And About
1.4% In 1372
*
According to U.S. Tariff Commission records 354, 593 lbs. PCBs were imported in 1972, and 640. 610 lbs. in 1971 (39).
Before 1971 this information was lumped in a general chlorinated hydrocarbons category in these records.
Pursuant to Customs Bureau Directive CIE 36-72, July 14, 1972 the field offices of the Customs Bureau have been specifically monitoring the inflow of PCBs, and this information is forwarded to EPA (40). The information is not public.
It should be noted that the quality of Import statistics as well as the effectiveness of monitoring PCB inflow can be influenced by
- how the imported chemicals are labeled and represented
- whether or not PCBs are a principal component or lesser ingredient of imported chemicals
- whether or not PCBs are an integral part of transformers and capacitors or products with these as components, or in rubbers, plastics and adhesives. These are the principal pro ducts with which imported PCBs are thought to be associated (38) .
- the extent to which the above information is available during the importation cycle.
IV-7
HONS 209474
(2) Imports of PCBs Are Expected To Be Less Than 2% of Total U.S. Sales During The Next Five Years
This is the same order of magnitude as the 1971 and 1972 imports.
The decline in world commerce is expected to be reflected also in imports.
(3) During The Period From 1963 Through 1972 Exports of Aroclors Were 78.7 Million Lbs.
This represents 15% of U.S. sales of Aroclors over this period, which were 522.4 million lbs.
Exports of Aroclors to Canada are estimated to have been about 7% of U.S. sales, or about one-half the total exports (38).
(4) Exports of Aroclors Are Expected to Maintain The Same Ratio To U.S. Sales As In The Past Several Years (36), Or 10-15%
(5) Known ForeiRn Producers of PCBs Include Czechoslovakia France, Germany, Italy, Japan. Spain, and The U.S.S.R.
. Several tradenames have been reported (11.38)
- France: Pyralene and Phenoclor (Prodelec)
- Germany: Clophen (Farbenfabriken Bayer)
- Japan: Kannechlor (Kanegafuchi Chemical); Santotherm (Mitsubishi-Monsanto)
- Italy: Fcnclor (Caffaro)
- Spain: (Eleclro-Quimica de Flex)
- U.S.S.R.: Sovol
IV-8
HONS 209475
Producers in France, Germany, Japan. Italy and Spain are the most likely sources of imported materials.
Possible new producers may be located in Argentina. Brazil, East Germany and India (1).
Historical use and loss patterns of PCBs are expected to be broadly similar in all industralized countries (38).
Total production of PCBs outside the U.S. have been roughly estimated to equal the U.S. production Cl), corresponding to an annual rate of up to 80 million lbs.
The combined PCB output of the Western European producers. Prodelec, Bayer. Caffaro and ElectroQuimica de Flex, was 75 million lbs. in 1971.
In 1970 it was reported that Japan was producing PCBs at an annual rate of 26 million lbs. (38) .
- capacitors: - transformers: - heat transfer: - plastics:
- carbonless paper: - export:
40-50% 15% 10-15% 5% 15% 5-10%
The use and production of PCBs was recently banned in Japan, but manufacture of PCB bearing products (such as air conditioners with askarel capacitors) by Japanese interests for export may be taking place in Taiwan (36). There is evidence of exemptions to the ban (36).
World-wide, the non-U.S. production of PCBs has also probably decreased
- due to the Japanese action noted above
- due to the recent agreement of the Organization for Economic Cooperation and Development (OECD) to limit sales principally to use in transformers and capacitors and some minor essential heavy industrial applications (31).
IV-9
HONS 209476
Farbenfabriken Bayer stopped marketing PCBs for plasticizer uses before the OECD agreement (41) .
World Commerce In PCBs Is Expected To Decrease By About The Same Amount Or More Than In The U.S. Since 1970, And To Be Essentially Confined To`Capacitor And Transformer Applications
, Japan will not produce PCBs
. The 1970 Aroclor production was 85 million lbs. Estimated 1973 production is 43 million lbs*, accounting for a 50% reduction
. Western Europe will produce 30-40 million lbs. annually
. In the long run the remaining world producers will also show a pattern of reduced PCB production in the wake of developments in the U.S., Western Europe and Japan.
1V-10
HONS 209477
Components Given as % Chlorine* Biphenyl MonO'Chlorobiphenyl Di-chlorobiphenyl Tri-chlorobiphenyl Tetra - chlorobiphenyl Penta-chlorobiphenyl Hexa-chlorobiphenyl
1221 1232 21 32 14.8 56.5 26.9 a^55
1.42 .06
EXHIBIT I Cl) EPA
COMPOSITION OF DIFFERENT LIQUID PCB PRODUCTS
Monsanto Aroclors (1)
MCS
MCS
1043
1242
1016
1248
32 42 42 48
.04 .02 .02
22.2
.72 .93
74.4
15.6
19.4
3.3 54.5 64.5
22.5
15.0
^55
6.7**
.16**
1254 54
60
1260 60
70
The last two digits of each Aroclor type indicate the percent chlorine content, except for MCS 1016 and 1043.
* * Includes higher than penta-chlorinated isomers.
HONS 209478
Homolog No. of Cl/Biphenyl
0 1 2 3 4 5 6 7 8
EXHIBIT 1 (2) EPA
COMPOSITION OF DIFFERENT LIQUID PCB PRODUCTS (continued)
Homolog Distribution of Aroclors Currently Marketed (12)
Percent Composition* 1221 1016 1242 1254
11 51 32
4 2 <0.5 ND** ND ND
<0.1 1
20 57 21
1 <0.1 ND ND
<0.1 1
16 49 25
8 1 <0.1 ND
<0.1 <0.1 <0.5
I 21 48 23
6 ND
* Percent (w/w) by GC/Mass using area correction factors ** None detected, <0.01% = ND
MONS 209479
1957
1957 thru 1964
(Thousands of Pounds)
1958
1959
1960
EXHIBIT II (1) EPA
PCB MANUFACTURE AND SALES MONSANTO INDUSTRIAL CHEMICALS CO.
1961 1962 1963 1964
U.S. PRODUCTION DOMESTIC SALES U.S. EXPORT SALES
(1) 32299
(2)
(1) 26061
(2)
(1) 31310
(2)
37919 35214
(2)
36515 37538
(2)
38353 38043
(2)
44734 38132
3647
50833 44869
4096
DOMESTIC SALES BY CATEGORY
Heat Transfer Hydraulics/Lubricants Misc. Industrial Transformer Capacitor Plasticizer Appl. Petroleum Additives
1612 704 12955 17028
(1)
1549 755
5719 14099
3939 -
_
2685 1569 5984 16499 4573
"
2523 1559 7921 16967
6244 "
4110 2114 6281 15935 9098
157 3915 1681 7984 15382 8924
582 3945 1528 7290 15606 9181
929
4374 1692 7997 19540 10337
"
DOMESTIC SALES BY PCB GRADE
Aroclor 1221 Aroclor 1232 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1262 Aroclor 1268 Aroclor 1016
23 196 18222 1779 4461 7587
31 -
-
16 113 10444 2559 6691 5982 184 72
-
254 240 13598 3384 6754 6619 359 102
-
103 155 18196 2827 6088 7330 326 189
-
94 241 19827 4023 6294 6540 361 158
-
140 224 20654 3463 6325 6595 432 210
-
.
361 13
18510 5013 5911 7626
414 284
-
(1) Production figures and Plasticizer Applications figures unavailable during year indicated. (2) U.S. Export Sales figures unavailable during year indicated. (3) Sources: References 1, 36. 37.
596 13
23571 5238 6280 8535 446 190
-
HONS 209480
1965 thru 1972 (Thousands of Pounds)
1965
1966
1967
1968
u.s. production DOMESTIC SALES U.S. EXPORT SALES
60480 51796
4234
6 5849 59078
6852
75309 62466
8124
82854 65116 11231
DOMESTIC SALES BY CATEGORY
Heat Transfer Hydraulics/Lubricants Misc. Industrial Transformer Capacitor Plasticizer Appl. Petroleum Additives
1237 4616 1841 8657 23749 1169G -
1766 4258 1779
8910 28884 13481
--
2262 4643 1426 11071
29703 13361
"
2529 5765 1283 11585 29550 14404
-
DOMESTIC SALES BY PCB GRADE
Aroclor 1221 Aroclor 1232 Aroclor 1242 Aroclor 1248 Aroclor 1254 Aroclor 1260 Aroclor 1262 Aroclor 1268 Aroclor 1016
369 7
31533 5565 7737
5831 558 196 -
528 16
39557 5015 7035 5875 768
284 -
442 25
43055 4704 6696 6417 840 287 -
136 90
44853 4894 8891 5252
720 280
-
1969
763B9 67194 10624
3050 8039 1079 12105 25022 16460 1439
507 273 45491 5650 9822 4439 712 300
EXHIBIT 11 (2) EPA
PCB MANUFACTURE AND SALES MONSANTO INDUSTRIAL CHEMICALS CO.
1970
85054 73061 13651
1971
34994 34301
9876
1972
38600 26408
6388
Est. 1973
43000 36000
5400
3958 7403 1627 13828 26708 19537
3060 1552 1155 11134 14141 3259
752 -
(25676 (
-
36000
1476 260 48588 4073 12421 4890 1023 330
-
2215 171
21981 213
4661 1725
1 3334
176 72 8 807 3495 . 305 -
-
20902
100
-
1100 -
6000 -
-
29000
HONS 209481
End-Use Sales Existing
Capacitors
1016 XX
Transformers
Sales Phased-Out
Heat transfer
Hydraulics/ lubricants
. hydraulic fluids . vacuum pumps . gas-transmission
turbines
Plaslicizers
. rubbers . synthetic resins . carbonless paper
EXHIBIT III (1) EPA
END-USES OF AROCLORS
1221
1232
1242
1248
1254
1260
12621268
X XX
x-
past
X XX x
past
X
XXX X X XX
XX
XXXXX X XXX
X
X X
*ONS 209482
EXHIBIT VIII (17) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
(3) Nonreclaimable contaminated transformer askarels, arced askarels. askarels from manufacturing spills, and sump accumulation, etc., rich in PCBs and askarels from holding basins, drip and drain pans, washings, sample jars and containers, etc.
b. Burnable Solid Waste Material Containing PCBs, These materials can be disposed of by hightemperature incineration and consist of cellulosic materials, rags, pressboard, wood, sawdust, fuller's earth in bulk or in cloth bags, blotter papers, nitrile or cork gaskets, etc.
c. Nonburnable Solid Waste Materials Containing or Contaminated With PCBs. These materials may consist of coil structures, steel, copper, aluminum filter units of the steel mesh construction type, askarel drums, cans, etc.
Materials of this nature should be allowed to drain with the liquid collected in drip pans, etc. Further removal of adhering PCBs can be accomplished by washing or solvent extraction with kerosene or other approved washing liquids such as perchloroethylene or trichloroethylene. Accumulated liquids can be disposed of as indicated in par. F.2.a. Solid materials may be handled as normal scrap.
3. Shipment of Scrap Liquids for Disposal
All liquid scrap material should be placed in appropriate metal transport drums, properly labeled, for shipment to a company offering an acceptable disposal service.
4. Shipment of Burnable Solid Waste Matcritil Containing PCBs for Disposable
Material of this type should be placed in open head drums with suitable closures and with the drum properly labeled for shipment to a company offering an acceptable disposal service.
HONS 209483
EXHIBIT VIII (18) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
Liquid and Solid Waste Disposal Service Organizations
a. General. Disposal of askarels and askarel-soaked materials should be accomplished by means in which there is no significant release of askarel to the en vironment. At present, disposal is accomplished by carefully-controlled incineration of liquids and soaked software, and by controlled landfill burial of apparatus and other hardware from which askarel has been previously drained and washed.
Present knowledge Indicates that proper incineration must involve a suitable balance between dwell time and temperature in the incinerator plus oxygen availability and, finally, suitable scrubbers to remove the HCl which will be formed; e.g., (I) 2-second dwell time at 2000F and 3 percent excess oxygen in stack gas; (2) 2 1/2-second dwell time at 2700F and 2 percent excess oxygen in stack gas.
These facilities should meet the applicable require ments of the State in which they are located and should control effluents within the limits set forth in thi6 document.
Controlled landfill or deep-well disposal can be used where permitted by Federal, State and local regula tions .
b. Costs. In addition to the normal costs of collecting scrap liquids and solids for disposal, additional costs borne by the owner of such scrap include shipping containers, cost of transport to the disposal service organization, and a disposal fee usually based upon a per gallon or per pound charge.
c. Disposal Services. Organizations offering disposal services are listed in Section 4. including their loca tion, facilities available, types of material handled, and disposal procedures used. Specific shipping directions, disposal procedures and costs should be obtained from the organization.
HONS 209484
EXHIBIT VIIIC19} EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
SPECIFIC GUIDELINES
A. Transformer Manufacturers. Service Shops, - Housekeeping
It is necessary to assume that in filling equipment with askarel and during further handling of this equipment an askarel spill may occur. Therefore, it is necessary to provide facilities and a procedure for clean-up to prevent contamination.
1. Askarel Filling Area
a. The location of the askarel filling area should be adjacent to the test area and final shipping area to minimize the danger of damage of units during handling.
b. The main manufacturing area for filling equipment with askarel should be provided with impervious surface floors or suitable basins so constructed that any inadvertent leakage or spills are prevented from reaching streams, sanitary, or storm sewers. All askarel handling equipment such as pumps, hoses, etc. shall be of the askarel resistant type.
c. Drip pans shall be provided for hose connections and filling valves.
2. Special Containers for Scrap Materials
a. Drums labeled "SCRAP ASKAREL" should be avail able for handling all spilled and waste askarel from sumps, failed units, drip pans, sample jars, etc.
b. Open-head drums with suitable closures and labeled "SCRAP BURNABLE ASKAREL WASTE" should be available for handling contaminated cellulose insul ation, rags, paper pressboard. wood, gaskets, saw dust, etc.
HONS 209485
EXHIBIT VIII (20) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
c. Separate containers for handling steel, copper, and aluminum, each adequately marked, shall be provided for the components of contaminated core and coil assemblies. These containers are required for the various materials when repairing or scrapping assemblies.
d. Containers for supplies of material for absorbing small askarel spills or clean-up of larger spills should be provided.
Conditioning of Askarels
a. Askarel Conditioning Equipment. The conditioning unit should be located either in the storage tank area or the main transformer manufacturing area for filling with askarel.
b. Fuller's Earth. Conditioning of new askarel or recycled askarel requires fuller's earth treatment. The spent fuller's earth in cartridges or bags, when replaced should be allowed to thoroughly drain over drip pans to remove as much liquid askarel as possible. The cartridge units of steel mesh construction should be placed in the "STEEL CONTAMINATED WITH ASKAREL" container for disposition. Cloth bags filled with fuller's earth should be placed in the "SCRAP BURNABLE ASKAREL WASTE" container for disposition.
Teardown of Units for Repair or Scrap
a. Drain all askarel from the unit either into a holding tank for reuse or into the drum labeled "SCRAP ASKAREL" for disposition, and then allow sufficient time for all of the askarel to drain from the core and coils.
HONS 209486
EXHIBIT VIII (21) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
b. Remove the core and coil assembly from the transformer. Sufficient absorbent material should be placed on the floor to absorb any askaret fluid that still drips from the trans former.
c. Place all materials in the appropriate salvage containers during the dismantling for later disposition.
d. All used materials. Including rags, sawdust, tape. etc., regardless of quantity, shall be put into the appropriate containers for disposition.
Transformer Labeling
1. New Transformers
All new transformers that contain PCBs shall have a label of adequate durability permanently and prominently attached to the tank by the manufacturer, giving adequate warning and instructions.
2. In-service Transformers
The transformer manufacturer should make available suitable labels with a similar warning as shown in par. B.l for use on existing transformers.
Transformer Users - Shipping, Installation. Maintenance, Sampling. Apparatus Disposal
1. Ceneral
Askarel-filled transformers are delivered to customers as sealed units from which there is no escape of askarel under normal operation. While certain types of equipment failures can permit loss of some askarel to the environment, such cases are extremely rare.
HONS 209487
EXHIBIT VIII (22) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
2. Transportation and Receiving
Immediately upon receipt of the equipment and following any transportation or handling accident which could affect the integrity of the tank, bushings or radiators, the transportation vehicle, tank and fittings should be examined for any leakage or spillage that may have occurred in shipping. If leakage is evident, the cause should be corrected and the spillage soaked up with absorbent materials such as sawdust, followed by a clean-up of the affected area with rags soaked with kerosene or other approved solvent such as perchloroethylene or tri chloroethylene. All materials used should be collected for proper disposition as described in Section 3 Part I. par. F. "Disposal Procedures and Services."
3. Installation and Periodic Inspection
Following installation, the unit should again be inspected for any damage or leakage. It is recommended that periodic in-service inspections be made for any leaks.
4. Filling, Filtering, or Drying Askarel
Most askarel units are shipped with the proper amount of askarel but if it becomes necessary to top off a unit, the manufacturer's instructions should be followed.
If it is necessary to dry or fuller1 s-earth treat an askarel unit, the manufacturer's instructions should be followed. When filtering or conditioning askarel, all of the precautions previously described for drip pans, proper disposal of filter media, etc., apply.
5. Sampling
U is common practice to sample askarel from a transformer for periodic maintenance testing. As previously described, such samples should be taken in a manner to avoid any contamination of the environment. Washings should be collected for proper disposal. Field and laboratory test samples, washings, etc. should also be collected for proper disposal.
HONS 209488
EXHIBIT VIII (23) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
6. Transformer Disposal
'
The ultimate disposal of an askarel-filled transformer may be accomplished in either of two ways:
a. Complete drainage and dismantling with the proper disposal of the askarel and askarel-soaked com ponents as described earlier in Section 3, Part I, par. F, "Disposal Procedures and Services."
b. Disposition of askarel transformers by means of junk or scrap dealers should be avoided unless a transformer is first drained, followed by soaking the interior with a suitable solvent. Accumulated liquids and washings are to be disposed of as described earlier.
HONS 209489
EXHIBIT IX (1) EPA
* DISPOSAL SERVICES LISTED IN SECTION 4 OF NEMA'S OFFICIAL STANDARDS PROPOSAL (16)
SECTION 4 DISPOSAL SERVICES
Chem-Trol Pollution Services, Inc. 4616 Lake Avenue Blasdell, New York 14219 Phone 716-626-5850 This organization has facilities and services capable of handling: 1. Liquids Askarels alone or mixed with solvents or oils. Disposal by high temperature incineration. 2. Solids (Software) Askarel-soaked compounds, rags cartons, absorbing earths, etc. Disposal by incineration or scientific landfill. 3. Solids (Hardware) Capacitors, transformer tanks, cores, askarel-soaked metals. Disposal by scientific landfill. Has solvent extraction capability.*
* Disposal Services Listed in Section 4 Of The National Electrical Manufacturers Association (NEMA) Official Standards Proposal (16) For Handling And Disposal Of Capacitor - And Transformer - Grade Askarels Containing PCBs.
HONS 209490
EXHIBIT IX (2) EPA
DISPOSAL SERVICES LISTED IN SECTION 4 OF NEMA'S OFFICIAL STANDARDS PROPOSAI (16) (continued)
Monsanto Company 800 No. Lindbergh Boulevard St. Louis. Missouri 63166 Phone 314-694-3352
This organization has facilities and services capable of handling askarel liquids alone or mixed with other oils or solvents by hightemperature incineration. Liquid is pumped through a gun with atomizing steam into incinerator. Temperatures are maintained at 2000-2500F with auxiliary natural gas. Exit gases are quenched to 160F by contact with water. Gas is then passed through a high-energy venturi scrubber for removal of particulates. Before exhausting to air (110F). gases are passed through a packed column scrubber to remove HC1.
Nuclear Engineering Company Eastern Division P.O. Box 146 Morehead, Kentucky 40351 Phone 606-784-6611
Disposal Division Sheffield. Illinois Phone 815-454-2624
This organization provides containerization, transportation and disposal services of all liquids and solids (including hardware). Disposal is in controlled chemical and scientific landfill area. AEC licensed for radioactive waste disposal. Has two West Coast locations in states of Washington and California in addition to above.
HONS 209491
EXHIBIT IX (3) EPA
DISPOSAL SERVICES LISTED IN SECTION 4 OF NEMA'S OFFICIAL STANDARDS PROPOSAL (16) (continued)
Ro)lins-Pur)e. Inc. Box 3349 Wilmington, Delaware Phone 302-478-5150
19899
This organization has facilities and services capable of handling:
1, Liquids
Askarel alone or mixed with solvents or oils. Disposal is by high temperature incineration.
2. Solids (Software)
Askarel-soaked compounds, rags, cartons, absorbing earths, etc. Disposal is by incineration at combustion temperatures up to 2500F. Incineration gases are scrubbed, and entrained solids re moved before exhausting to air.
Disposal facilities are available at the following locations:
Logan:
Rollins-Purle, Inc. Route 322 Logan Township Bridgeport, New Jersey
08014
Baton Rouge:
Rollins-Purle. Inc.
Scenic Highway s W, Cheatham Lane
Scotlandville East Baton Rouge Parish Louisiana 70007
Houston:
Rollins-Purle. Inc. Tidal Road 6 Highway 134 Deer Park, Texas 77536
HONS 209492
SECTION VI HONS 209493
t
SECTION VI MANUFACTURING PROCESSES IN WHICH PCBs ARE USED
in this section the end-uses of PCBs are discussed both in marketing and technical terms to define the principal channels of movement of these substances through our economy. Emphasis is placed upon the capacitor and transformer applications because currently essentially all PCBs are sold in the U.S. for these uses, and because of the reported technical problems involved in finding replacement materials. Other end-uses, for which the sole U.S. supplier has discontinued sales, are discussed in broader terms.
Based on this information, a crude accounting of PCBs' entry into the environment is developed.
1. DURING THE PERIOD FROM 1857 THROUGH 1973 (PROJECTED) . ACCUMULATED U.S. CONSUMPTION OF PCBs WAS ABOUT 775 MILLION LBS., INCLUDING IMPORTS
This is based on sales of Aroclors during the same period in the U.S. and the conservative assumption that imports accounted for 2% of total domestic consumption.
Exhibit X summarizes the distribution of U.S. production during this period to the Aroclor types and principal end-uses.
(l) During The Period From 1957 Through 1873 Approximately 234 Million Lbs. Of PCBs Were Used In "Open11 Systems And Approximately 541 Million Were Used In "Long Lived Contained" Systems
. "Open" systems include the following end-use categories:
- hydraulics/lubricants, where losses can be relatively continuous due to leaks, maintenance problems and where make-up is required
- plasticizer applications, where PCBs can gradually evaporate from large surface areas
- miscellaneous industrial applications where PCBs occur often at low levels in widely distributed products and processes.
VI-1
HONS 209494
Of the roughly 2% of U.S. consumption that is imported only a fraction is likely to be imported in the form of or destined for open systems.
"Long Lived Contained" systems include the following end-use categories:
- electrical systems, capacitors and transformers which are sealed, have long service life and low failure rate
- heat transfer equipment, where exchangers are also sealed and have relatively long life and low failure rale
Currently essentially all PCBs sold in the U.S. are for long lived, contained electrical systems due to the voluntary restriction on sales by Monsanto.
(2) During The Period From 1957 Through 1971, Approximately 46% Of Aroclors Sold In The U.S. Were The Trichloro Or Lower Chlorobiphenyls (12)
. The trichloro and lower chlorobiphenyls are markedly less persistent in the environment than the higher homologs. See page IV-3.
. The pattern of historical end-uses in Exhibit III
suggests that much of the less persistent PCBs were
consumed in open systems.
.
. Currently the relatively low to moderately persistent Aroclor 1016 is the principal product consumed (capacitors); the moderately persistent Aroclor 1254 is purchased in appreciably lesser amounts (transformers) Small quantities of Aroclor 1221 and Aroclor 1242 are also used.
(3) An Estimate Of The Total Aroclor Used In The U.S. In Electrical Systems Since 1934 Is 752 Million Lbs.
. This is based on Boquist's (44) estimate of 690 million lbs. through 1971, adjusted for 1972 and projected 1973 consumption.
VI - 2
HONS 209495
- Assume conservatively that prior to I960 the ratio was 70:30 of electrical system usage to other usage (44) . This is reasonable since many of the open system applications of PCBs were promoted in the early 1960's.
- From 1960 through 1973 approximately 436 million lbs. Aroclors were consumed in electrical systems.
- Then, about 314 million lbs. Aroclors were used in electrical systems from 1934 to 1960.
Based on the above reasoning, about 135 million lbs. Aroclors were used in applications other than electrical from 1934 to 1960.
(4) An Estimate Of The Total Aroclor Used In The U.S. In Non-Electrical Systems Since 1934 Is 367 Million Lbs.
. This is based on the 135 million lbs. estimate for the 1934 to 1960 period, and sales figures of approximately 232 million lbs. since 1960.
. Open system usage and heat-transfer applications are accounted for.
(5) An Estimate Of The Reasonable Upper Limit On Total FCB Consumption In The U.S. Since 1934 Is 1,175 Million Lbs.
. This represents 567,000 tons.
. The figure is based on the above Aroclor consumption estimates, adjusted upward by 5% for possible Imports,
. and statistical uncertainty prior to 1957.
(C) Before 1971 There Were 10 To 15.000 Direct Purchasers of Aroclors, While Currently There Are 25-30
, These purchasers ordered Aroclors directly from Monsanto
VI - 3
HONS 209496
i
Papageorge (36) reported that the order of magnitude of purchasers of Aroclor in 1971 or before in each end-use category is as follows:
Heat Transfer Hydraulics Lubricants Misc. Industrial
Transformers and
Capacitors
:
Plasticizer Applications :
2 .000 3,000 "few" "several thousand"
40 - SO 2.000
Many of these purchasers were distributors further disbursing PCBs to countless small accounts (36)
Since Monsanto's voluntary restriction of sales and other control actions, there are currently 25-30 direct customers, all in transformer and capacitor applications. These customers use PCBs as askarels in the finished products (capacitors and transformers) or in the course of servicing.
VI - 4
HONS 20949?
2, 1973 USE OF PCBs BY THE U.S. ELECTRICAL INDUSTRY IS ESTIMATED AT 36 MILLION LBS. AND IS EXPECTED TO INCREASE TO ABOUT 51 MILLION LBS. BY 1978
PCBs alone or as mixtures with chlorinated benzenes are used as dielectric liquids known as Askarels, in transformers and capacitors. Besides their electrical functions, these impregnating liquids serve cooling and arc quenching functions.
Transformers are devices for converting electrical power from one voltage and current level to another, and the conducting parts of these devices must be separated from each other by a suitable insulating medium such as oils, PCBs or others.
Capacitors are devices for storing electrical energy through the physical separation of charged metal surfaces by an insulating medium.
Because of the nonflammability of PCBs, their vapors, and their arc-formed gaseous products, transformers filled with PCBs are relatively free of fire and explosion hazards and may be used in locations where failures of oil-insulated transformers would present a potential danger to life and/or property. In addition to improving the safety aspect of capacitors, PCBs also have the advantage of reliability, long life and small size.
Exhibit XI summarizes U.S. PCB sales to the electrical industry for the 1963-1973 period and estimates of 1978 sales.
(1) The Average Annual Growth Rate For PCB Use By The Electrical Industry During The 1963-1973 Period la 4,6% And This Is Expected To Increase At About 7.4% Per Year Through 1978
. PCB use in transformers has grown at the rate of 5.1% per year for the 1963-1973 period equalling the rate of growth of the value of transformer shipments shown in Exhibit XII for the same period. Industry sources (51) indicate that future PCB use will increase at a rate of about IQ* per year and could account for about 19 million pounds per year of PCBs sold for transformer use by 1978.
VI - 5
HONS 209498
- There will be an increased demand for power and distribution transformers emanating from expansions and maintenance of the electrical utilities industry.
- Demand for specialty transformers with PCB is basically derived from industrial and commercial construction
.. Transformers are located inside public, commercial or industrial buildings, on the roof tops of such buildings or in close proximity to such buildings.
.. Because PCBs are used, they require no special enclosures other than that necessary to prevent accidental hazardous, mechanical or electrical contact with the equipment.
- Generation and use of electrical energy will probably be at a higher rate in the future in spite of general fuel shortages-
PCB-insulated transformers share only about 5% of the total market.
- About 125.000 such transformers have been put into service in the United States since 1932 and current production is at the rate of about 5,000 units per year (45).
.. The amount of Askarel used in various types of transformers ranges from 40 to 500 gallons (516 to 6,450 lbs.) with an average of about 235 gallons (3,032 lbs.) .
. . The principle PCBs used are those designated as Aroclor 1254 and 1242 (54% and 42% chlorine respectively) .
PCB use in capacitors has grown at a slower rate than its use in transformers and over the 1963-1973 period averaged 4.4% per year. Industry sources (50) indicate growth will be somewhat higher over the next five years amounting to about 6% annually and account for 32 million lbs. per year sold for capacitor use by 1978. Reasons given were:
VI - 6
HONS 209499
Creeter emphasis by lighting manufacturers to provide more controlled lighting distribution spurred on by OSHA enforcement as it pertains to illumination standards for better working con ditions .
Strong demand by new construction of industrial
and commercial building.
'
Greater public awareness of safety and security requirements giving impetus to more emergency lighting systems and a trend to relamp streets.
Increased requirements for new motor and generator production for air conditioners, pumps, compressors and other general industrial and consumer equipment and appliances.
Overall, kvar production will increase, but the total unit capacitor growth will not be equal because of
improvements in capacitor design (use of polypropylenecellulose combinations).
(2) Present Production And Handling Procedures Adopted By Major Transformer And Capacitor Manufacturers (16) Can Minimize Environmental Contamination (50) .
Specific control measures instituted by major manufacturers prevents the inadvertent loss of PCBs to the environment at all stages from initial receipt of askarel through ultimate disposal of rejected units.
- All shipments of askarel are made in closed containers such as rail tank car, truck tanks, marine or barge tanks or sealed drums.
- Transfer from shipping containers to processing systems are via closed piping, with appropriate valves, pumps, etc., provision is made for trapping and dis posing of fluid lost by leakage or spills from the transfer system and from storage containers.VI
VI - 7
HONS 209500
. Capacitor manufacturing involves several additional product handling steps generating waste fluid which must be incinerated and about 5% scrap reject units which are disposed in dry-land fill sites (50) .
* Metal-cellulose or metal-cellulose/polypropylene laminates are sealed in metal containers which have a weep hole at the top.
- The containers are placed in an impregnation-chamber heated under vacuum and dipped into a vat containing PCB and the PCB is sucked into the container through the weep hole.
- The capacitors are then raised and excess PCB is allowed to run off by gravity, and the weep holes are sealed by applying solder.
- The outside of the capacitors are degreased with a suitable solvent which is then disposed of by incineration.
. Exhibit XIV illustrates magnitudes of losses of PCB and disposal practices in one capacitor plant before and after controls (38). The exhibit also presents evidence that air pollution from capacitor manufacture is probably not signi ficant (50).
The Capacitor And Transformer Manufacturing Industry Is A Highly Concentrated Industry
. According to the National Electrical Manufacturers Association (16). its member companies have the major share of this market to the utility Industry.
.
- 22 transformer producers - 6 capacitor producers
. According to the Certified Ballasts Manufacturers
Association (53) there are only 10 manufacturers of fluorescent lamp ballasts.VI
VI - 9
HONS 209501
- Manufacturing equipment and operating procedures safeguard against loss of askarel to the environment.
.. Enclosure systems of sealed piping, properly gasketed joints, valves, containers and pro cessing chambers should be used where askarel temperature may exceed 5SC.
.. All wiper rags, clothing, waste fluids are collected and properly disposed.
- Scrap capacitors generated either during manufacture or failure In the field should be disposed of in super vised dry land-fill sites which meet State requirements
- Askarel or askarel containing fluids can be incinerated at designated facilities- See Exhibit IX.
The flow of askarel through a typical transformer manu facturing plant is essentially a closed system (SO).
- Bulk askarel, on receipt, is pumped to a storage tank.
- Askarel is transferred to the transformer filling operation (transformers can be filled directly or under vacuum) and any overflow is drained off and sent to a separate storage tank. The drained askarel is filtered through filter clay and reused.
- Transformers are then sealed, wiped clean, and shipped to customer.
Transformers that fail in the field are returned to the manu facturer or authorized repair stations (50) .
- The askarel or other insulating fluid is drained and sent to approved incinerators.
- The transformer is repaired, filled with new askarel or other insulating oil under strict supervision and returned to service.
VI - 8
HONS 209502
(4) The Consumer Sector (Primarily Electric Utilities) Is Becoming Increasingly Conscious Of The Need To Reduce Environmental Contamination
. Industry contacts (54) Indicate that steps are being taken to eliminate transformer fluids from entering plant effluent streams by building confining walls around transformer stations. While certain types of equipment failures can permit loss of some askarel to the environment, such cases are extremely rare and are limited to approximately 0.021 of the units in service per year (1.16).
. Utilities are beginning to return failed capacitors to the manufacturers, (54). Capacitor life expectancy for lighting applications is more than 10 years and more than 20 years in electrical utility applications so that losses due to in-service failure are limited to approximately 0.02% of the askarel put into service per year (1.1B) .
(5) The Value Of Imported Transformers In 1973 Is Estimated At 50 Million And Is A Small Portion Of Total Transformer Sales
The annual average rate of growth of Imports (current dollars) for the period 1967 - 1973 is 12.2% but comprises only 3.4% of 1973 U.S. value of shipments. See Exhibit XV.
Sweden is the primary supplying nation to the U.S. although other supplying nations and major companies include the following:
VI - 10
MONS 209503
Major Foreign Companies Exporting Transformers To The U.S. [46)
Country
Firm
Britain
F erranti-Packard Hawker-Siddely
France
Cognel
Italy Japan
Legnano
Fuji Hitachi Mitsubishi Sumitomo Toshiba
Sweden
ASEA
Switzerland
Brown-Boveri
Probably only few Imported transformers contain insulating oils due to shipping, handling and cost considerations, and the number of aekarel type transformers imported is probably relatively Insignificant.
VI - 11
HONS 209504
(6) Near Term Replacement Of PCBs In Moat Askarel Electrical Applications Is Technically Not Feasible
Although significant research effort has been, and continues to be spent, in finding replacement liquids for PCB. no substitutes have been found which provide the safety, reliability and economics of PCB.
- Mineral oil-insulated transformers can be substituted for PCB insulated transformers on a technical basis but other considerations must be taken into account (1)
.. Safety building codes specify nonflammable oils which eliminates use of mineral oil.
.. Serious economic constraints would occur by using insulated buses (with transformers located out- ' doors) and protective vaults costing 15,000 to $50,000 more per transformer if space is avail able (1) .
- Dry-type transformers cannot be directly substituted for PCB-insulated transformers (1),
.. Reliability of dry-types is much less showing a 7% per year failure rate compared to 0.2% for liquid-insulated units. (1).
.. PCB-insulated transformers have a much greater overload capability and many can sustain a 100% overload for 8 hours and a 200% overload for 2 hours thus maintaining continuity of electric service during periods of temporary malfunction of related equipment (1) ,
., Some dry types are larger by 10 to 30%, putting space constraints on their use (1).
.. Dry types are noisier by 5-10 db (1).
. . Open dry types cannot bo used in certain corrosive or hazardous atmospheres (1).
VI - 12
HONS 209505
Replacement of PCB use In capacitors with other liquids would have serious consequences in terms of size, reliability, failure rate and safety.
- Reverting to an oil-paper dielectric system would increase the average capacitor volume by approximately 600%, the weight by 500% and cost by 400% (44) .
- The chemical. thermal and oxidative stability of PCBs in the presence of capacitor tissues and plastic films and the favorable stress distribution between solid and liquid have made it possible to design low-cost capacitors of more than 10 years life in lighting applications and more than 20 years in electric utility applications (1). First-year failure rstes have been reduced to less than 0.2% (1).
- The relative nonflammability of PCBs significantly re duces the fire hazard that might otherwise accompany those failures that result in the rupture of the case.
VI - 13
HONS 209506
3. OPEN SYSTEMS END-USES HAVE ENCOMPASSED A BROAD RANGE OF APPLICATIONS IN WIDELY DISTRIBUTED PRODUCTS AND PROCESSES
With Monsanto's voluntary restriction of sales to capacitor and trans former applications and considering the low volume of imported PCBs. the use of these commodities in open systems has necessarily dramatically de clined. Soma PCB use probably still exists in these applications from past stockpiles, recycling and. in low quantities from imports, while the input of PCBs to open systems have been severely restricted suddenly, the scrapping of these materials from these sources is likely to be more gradual due to dwindling inventories and the natural decontamination of facilities.
(1) The Applicability Of PCBs In Open Systems Is Wide-Ranging
. The technology of use of PCBs in open systems and also in heat transfer is summarized in Exhibit XVI.
. In terms of PCB quantities consumed, before 1971 the decreasing order of Importance of these applications was as follows:
- plasticizers - hydraulics/lubricants - heat transfer - miscellaneous Industrial
. Petroleum additives and pesticide extenders were experi mental or short lived applications (36).
(2) In Most Open Systems Situations The Concentrations Of PCBs Associated With The Product/Process Have Probably Been Low Percentages
Exhibit XVII presents Snell's Judgments regarding PCB levels associated with various reported end-uses.
In heat transfer and vacuum pumps pure PCBs have been used.
The likelihood of direct contact by the general population has been significant in the carbonless paper application.
VI - 14
HONS 209507
PCB levels may have been 3 to 5% in this product (5).
Gradually declining use of PCB bearing paper can be expected as inventories are depleted and no more PCBs are used (36).
Evidence of this Is that In 1972, 95% of recycled paper board samples examined contained less than S ppm PCBs. Data on the same type of material manufactured in 1970 and 1971 show that only 18% of the samples contained less than 5 ppm (3).
(3) During The Next Five Years, Imports Are Expected To Be Essentially The Sole Source Of Fresh PCBs In Open System End-Uses With Investment Casting Accounting For A Major Portion
In these applications the use of PCBs are projected to be minimal compared to 1970 levels.
Imported PCBs in finished products are expected to decline as the use and production of PCBs is reduced or eliminated in Japan and Western Europe.
There is evidence that tha Yatea Manufacturing Company, Chicago, Illinois, is the principal open system importer of PCBs (55).
- the material is "Deka". decachloroblphenyl manufactured by Caffaro (Italy)
- 500,000 lbs. may be Imported annually
- about 30% Deka is used in formulating wax for Investment casting
- Yates distributes to 25 customers
- an environmental control program is ready to be initiated.VI
VI - 15
HONS 209508
.. Yates will accept spent wax from casters freight free, potentially representing about 98% of the quantities sold by Yates
.. Yates will pretrsat the recovered melt .. Caffaro will reprocess the recovered material .. The 1 1/2 to 2% wax retained in the mold can
be destroyed by the castors under an oxidizing atmosphere at 1600 to 1800F for 1 1/2 to 2 hours .. Yates is currently conducting long range toxicity studies Deka can be replaced by some benzene derivatives.
VI - 16 ! MOMS 209509
Aroclor
1221 1232 1242 1248 1254 1260 1262 1268 1016 Total
End-Use Category
.
Heat Transfer Hydraulics/Lubricants Miscellaneous Industrial Transformer Capacitor Plasticizer Applications Petroleum Additives Total
EXHIBIT X EPA
HISTORICAL DISTRIBUTION OF PCB TYPES AND END-USE
U.S. Consumption of Aroclors
1957 Through 1973 (Projected)
(000) Lbs.
Percent of Total
7.530 2,040 419.810 59.210 115.560 91,550 7,220 2,880 53,240 759,000
1.0 0.3 55.3 7.8 15.2 12.1 1.0 0.4 7.0
20,280 60,990 21.790 509.910 144.490
1.440 759.000
2.7 8.0 2.9 67.2 19.0 0.2
MONS 209510
EXHIBIT XI
EPA PCB USE IN THE ELECTRICAL INDUSTRY
U.S. Produced PCB Use In Transformers and Capacitors (1963-1978est.) (Thousand Pounds)
Year1
Transformer Use
Capacitor Use
Total
1963 1964 1965 1966
1967 I960 1969 1970 1971 1972 1973 (est.) 197B(est.)2
7.290 7,997 8,657
B.910 11,071 11,585 12,105 13.828 11,134 11.310 (12,000) (19 .320)2
15,606 19.540 23,749 28.884 29,703 29.550 25,022 26.708 14.141 14.366 (24.000) (32,120) 2
22.896 27,537 32,406 37.794 40,774 41,135 37,127 40,536 25.275 25,676 (36.000) (51,440)
PCB Manufacture and Sales; Monsanto Company Foster D. Snell, Inc. and Industry Estimates
HONS 209511
EXHIBIT XII EPA
TRANSFORMER TRENDS (1967-1974) (52)
(Million Dollars)
Year
Total Value of Shipments
Specialty Transformers
Power and Distribution Transformers
Power
Transformers
Regulators n.s.k.
1967 1966 1969 1970 1971 1972 1973 1974(est.)
1,134 1,253 1,296 1.389 1.344 1.397 1,460 1,550
206 228 271 287 270 279 295 310
790 657 886 902 903 950 1,010 1,050
121 15 154 14 128 11 115 25 146 26 154 14 160 15 170 20
MONS 209512
Year
1963 1964 1965 1966 1967 1968 1969 1970 1971 1972
Total Shipped (1,000 units)
36,091 40,641 48,217 51.617 45,206 51,102 53,117 60,917 45.522 54,960
EXHIBIT XJ1I EPA
FLUORESCENT LAMP BALLAST SHIPMENTS (1963-1972) (53)
Value ($1,000)
91,699 96,364 106,593 130.149 117,024 133,027 152.713 163,711 144,529 160.740
HONS 209513
EXHIBIT XIV EPA
PCS LOSSES IN CAPACITOR MANUFACTURE
A. MATERIAL BALANCE (381
I. PRODUCTS
Capacitors are produced ranging in size from fluorescent lamp ballasts to 100 KVA units, with motor start units for air conditioners as the main product.
II. PCS LOSSES BEFORE CONTROLS
During I960 the purchases of Aroclor 1242 were 3.7 x 105kg. 3.2 x 104 kg was lost in manufacture. Approximately 8.6% of Aroclor 1242 was lost. During 1989 the purchases of Aroclor 1254 were 1.5 x 104 kg. 2,3 x lO^kg was lost in manufacture. Approximately 15.3% of Aroclor 1254 was lost. The losees were approximately evenly distributed between scrap from units that failed and loss in purification and degreasing operations. Some of the scrap wae used as an antidusting agent in a parking lot and some mixed with a residual fuel oil and burned. No special precautions were practiced during disposal.
1U. PCB LOSSES AFTER CONTROLS During 1971 the purchases of Aroclor 1242 were 4.2 x 10S kg, and no Aroclor
1254 was purchased. Losses were reduced to 1.9 x 104 kg. or approximately 4.5%, mostly due to failures of units. All scrap fluids were disposed of by burial in sealed containers.
B. AIR EMISSIONS (SO)
Sampling of ventilation stacks in one capacitor plant where Aroclor 1016 had been used for about a year showed PCB levels of about 0.03 to 0.09 ppm by volume. Five stacks were sampled, using a 10-min sampling time per hour for a 25-hr period. A detailed description of the total ventilation system was not reported. Samples of air taken 2-3 miles from the plant showed no detectable PCB levels. Sampling waa done by methods suggested in the NEMA proposal (16) .
HONS 209514
YEAR
1967 1968 1969 1970 1971 1972 1973 1974 (est.)
EXHIBIT XV EFA
TRANSFORMER IMPORTS
VALUE OF IMPORTS (Million Dollars) 25 38 40 40 36 48 50 52
HONS 209515
EXHIBIT XVI (1)
EPA EXCERPTS FROM BROADHURST (19) ON PCB TECHNOLOGY IN OPEN SYSTEMS AND HEAT TRANSFER '
I. HYDRAULIC APPLICATIONS
Hydraulic fluids are liquids used as force transmitters.
Since most commercial hydraulic fluid mixtures are proprietary, it is difficult to obtain information with respect to their composition.
PCBs are useful in hydraulic fluids as lubricating additives in extreme pressure applications and aa pour point depressants. Although It is true that the pour point of oils may be lowered by extensive dewaxing, the use of additives is much cheaper. There are other inexpensive additives which are often used for these applications and which appear to be adequate. For example. TCP (tricresyl phosphate) is chemically stable as an additive in lubricants, and. although quite toxic, it ia more biodegradable than the PCBs.
.
An important requirement for many applications of hydraulic fluids ia good heat and fire resistance. PCBs have excellent fire resistance characteristics.
Aircraft hydraulic fluids are an example of an application where excellent heat and fire resistance are necessary in view of moderately high operating tempera tures and frequent accidents Involving ruptured hydraulic components in the proxim ity of hot metallic surfaces. Also the Fiberglas acoustic blankets in the jet engines become soaked with leaking hydraulic fluid within aa little as one year of use. Fire resistance in phosphate ester type hydraulic fluids has been related to PCB content. Phosphate ester hydraulic fluids have been used extensively for commercial aircraft. PCBs have been assumed to be useful as "snuffers" in that they tend to extinguish a fire supported by other constituents.
The market value of used phosphate ester type hydraulic fluids is sufficiently high that they are being recycled.
19. Broadhurst. Martin G.. Use and Replaceability of Polychlorinated Biphenyls. Environmental Health Perspectives: 81-102, October 1972.
HONS 209516
EXHIBIT XVI (2) EPA
EXCERPTS FROM BROADHURST (19) ON PCB TECHNOLOGY IN OPEN SYSTEMS AND HEAT TRANSFER (continued)
Considerable research is being done in connection with fire resistant hydraulic fluids for military aircraft Some of the hydraulic fluids being tested do not con tain PCB additives, but do contain TCP. It is possible that under appropriate process ing. PCBs may be replaced by TCP and perhaps certain other additives to obtain satisfactory lubrication.
It is possible that PCBs are also used in phosphate ester and other halogenated hydraulic fluids for Industrial applications at high temperatures,
11. VACUUM PUMP APPLICATIONS
PCBs are used In pure form as a diffusion pump oil In commercial applications. They are useful as booster pump fluids.
Except for certain applications where alternative liquids may be Incompatible with the vapors being pumped. the advantage of using PCBs in diffusion pump oils appears to be mostly an economic one, TCP is used as a commercial diffusion pump fluid and la also inexpensive. Its vapor pressure la lower than that of the PCBs making it leaa desirable In booster pumps, but in many applications TCP may be a suitable replacement. PCB diffusion pump oils can be decomposed after use by Incin eration ,
111, HEAT TRANSFER APPLICATIONS
The main advantage of the PCBs as heat transfer fluids Is their fire resistance. The other advantages of PCBs are low pour points and viscosities and good thermal stability up to 600F.
Increased risk from fire and explosion Is a major disadvantage with most PCB replacement fluids. Other non-flammable fluids are; 1. fluorocarbons, which have low toxicity, high thermal stability, and in spite of high cost are used as con vective or evaporative coolants. 2. water, which is quite corrosive, has a high temperature limit of 374C and requires extremely expensive high pressure systems for its use above the atmospheric boiling temperatures and 3. molten salts and metals which, because of their resistance to radiation damage, are useful in reactor applica tions ,
HONS 209517
EXHIBIT XVI (3) EPA
EXCERPTS FROM BROADHURST (19) ON PCB TECHNOLOGY IN OPEN SYSTEMS AND HEAT TRANSFER (continued)
Several liquids are more stsble at high temperatures than the PCBs. Few of these liquids are non-flammable- The phosphate esters, silanes, and aromatic ethers have high fire points (around 600F) , but they are flammable and it is not clear how high the fire point must be for a fluid to be safe in a high temperature system, especially in the event of leakage Into a furnace. The details of specific heat transfer applications are necessary to evaluate the suitability of PCB replacement fluids.
IV. PLASTICIZER APPLICATIONS
PCBs sre attractive as plasticizers because of their high compatablUty factor. The PCBs are permanently thermoplastic, chemically stable, non-oxldlzing, non corrosive, have excellent solvating powers, and are fire resistant. They are not normally attacked by acids, slkslles. or water. They are insoluble in water, glycerol, and glycols, and are soluble in organic solvents.
V. ADHESIVES APPLICATIONS
The more resinous chlorinated polyphenyls can be Included in this category, Hot melt adhesive compositions based on phenolic resins are used In brake linings, clutch faces, and grinding wheels. Chlorinated polyphenyls and aryl phosphates (non-reactive plasticizers) also improve flow properties of phenolic resins prior to curing as well as imparting some flame proofing characteristics to the composition. PCBs have also been used In laminating adhesive formulations involving polyurethanes and polycarbonates to prepare safety and acoustical glasses.
Polyarylene sulfides, treated with chlorinated biphenyls, are employed to
laminate ceramics and metals. An ethylene-propylene copolymer blended with
PCB has been used in a hot melt adhesive having Improved toughness and resistance
to oxidative and thermal degradation. It has excellent adhesion to polyethylene
films. Similar adhesives, used to bond polyethylene-to itself or other plastics.
were prepared from styrene, alpha-methylstyrene or methylmethacrylate.
Washable wall coverings and upholstering materials, made from films of polyvinyl
chloride, are claimed to be improved by the addition of PCB to the adhesive formula
tion. PCBs can also be applied in the preparation of polyvinyl alcohol adhesive
compositions which are used to manufacture envelopes, in self-adhering films
and in preparation of coatings of pressure-rupturable capsules for adhesive
tape.
.
HONS 209518
EXHIBIT XVI (4) EPA
EXCERPTS FROM BROADHURST (19) ON PCB TECHNOLOGY IN OPEN SYSTEMS AND HEAT TRANSFER (continued)
VI. TEXTILE COATINGS APPLICATIONS
-
A textile coating for ironing board covers can be formed from a mixture of chlorinated biphenyl, cellulose acetobutyrate, and aluminum metal particlea. PCBs alao can be used as a de-lustering agent for rayons. Poly-alpha-olefins, (i. e., polypropylene) films, when coated with a mixture of PCBs. UV light abaorbers. and antioxidants show increased stabilization to oxidative degradation on exposure to sunlight snd weathering. Polyamide (nylon-type) yarns were found to be flame proofed when treated with PCB. Chlorinated biphenyla can also be uaed as ingredients in some sealing formulations employed to waterproof canvas.
VII. SURFACE COATINGS APPLICATIONS
In paints and varnishes. the hard resinous PCBs impart increased hardness to films, and the softer resins give flexibility. In nitrocellulose lacquers. PCBs ' either alone or in combination with other plasticizers and resins impart increased weatherability, luster, adhesion, and decreased burning rates.
PCB and other plasticizers can be used in combination with poly (organosiloxanes) to prepare film casting solutions. These polymeric films could be employed in electrical coatings, Insulating tapes, and protective lacquers.
Plastic vessels, i. e. bottles, manufactured from polyethylene, polyvinyl chloride, polyvinylidene chloride or similar resins coated with an epoxy lacquer (which contains PCB) make the vessels pliant, impervious, and resistant to aromas, acids, and alkalis.
Paints at atomic energy installations are needed for (a) contaminated area (b) tolerance to high energy radiation, and (c) to meet clean condition standards. Paints for (a) should be glossy and smooth and should not transmit contaminants. For this purpose, the vinyl polymers are preferred over epoxy lacquers. The best plasticizers for use in thia area are claimed to be the PCBa. The extent, if any, of their use in this application is unknown.
.
The PCBs are usually compatible with epoxy resins, and they give good final hardness and impact resistance equal to the unmodified resin. They also aid
in the acceptance by the resin of larger amounts of fillers. Epoxy resins in combina tion with PCB can be used as protective coatings for metals, i. e., encapsulating electrical capacitors, for ferrite magnet cores, for corrosion resistant resistors, for pigmented metal coatings for winter camouflage coatings, and for pipes snd blocks.
HONS 209519
EXHIBIT XVI (5) EPA
EXCERPTS FROM BROADHURST (19) ON PCB TECHNOLOGY IN OPEN SYSTEMS AND HEAT TRANSFER (continued)
VIII. SEALANTS APPLICATIONS
PCBs can be used as plasticizers in the formulation of putties from copolymers
or ethylene-vinyl acetate or styrene. The products are non-hardening, and
resistant to moisture and frost and show good weather ability. A non-sticky, non
hardening putty was also prepared from polysulfide mixtures which employs PCB as
the plasticizer. This putty gave good bonding to building materials and had good
extrudability and shape retention. Elastic pavement or concrete sealing compo
sitions, used for traffic markings, were prepared from coal-tar-polysulfide mixtures
which are plasticized with PCB- A sealant, effective for concrete and asphalt
-
applications, can be formulated from a mixture of polysulfide, chlorinated rubber,
and polyisocyanate, and plasticized with PCB.
IX. PRINTING APPLICATIONS
Chlorinated biphenyls have been employed as part of the formulations used to prepare pressure-sensitive record and colored copying papers. They have been used to coat papers used in thermographic duplicating processes as well as in xerographic transfer processes. Solvent-free printing on polyolefin plastics can be accomplished by heating a mixture.of low molecular weight material, chlorinated biphenyl or terpene resin, and suitable pigments and dyes. Printing plates can be prepared from compositions containing a liquid resin such as epoxy, polyester, urethane, acrylic or vinyl with an excess of curing agent and PCB as the plasticizer. The extent, if any. of current uses of PCBs in printing application is unknown.
X. FIRE RETARDANT AND FLAME-PROOFING APPLICATIONS
For increased effectiveness in flame retardant applications, the PCBs can be admixed with various metal oxides. Some flame retardant compositions based upon these mixtures are used in: polyolefin yarns: organopolysiloxane sealants: thermoplastic poly; fireproof panels made from starch which can be used for doors, floors, ceilings, and partitions; polyamides; and in fireproof fiberboards.
XI. MISCELLANEOUS APPLICATIONS
Catalyst carrier for polymerization of olefins .
MONS 209520
EXHIBIT XVI (6) EPA
EXCERPTS FROM BROADHURST U9) ON PCB TECHNOLOGY IN OPEN SYSTEMS AND HEAT TRANSFER (continued)
Conversion of water-permeable soil to a non-permeable state. Soil is made non-permeable by applying to the soil a composition consisting of an ethoxylene-based resin, polyamide, camphor, and PCB as plasticizer. The compo sition has a density greater than water, and it hardens under water. It can be applied to river banks, where it flows down the bank, and after hardening, prevents penetration of water (soil erosion-retardant) .
Combined insecticide and bactericide formulations. The composition contains aldrin or dieldrin, naphthalene hydrocarbons, malathion, methoxychlor. lindane, chlordane. terpineol. and chlorinated biphenyl as active agents.
Inhibitors of microbial growth in enamel clay formulations.
Plastic sound insulating materials for railway cars.
Plastic (PVC) decorative articles which give the impression of internal scintillation.
Increasing the density of carbon plates by impregnation with PCB.
Graphite electrodes with low thermal expansion coefficients and high bending strengths.
Increasing the coke yield from coal pitch. The coke is very hard, dark, and brilliant.
As a metal quencher or tempering agent for steel. alloys. and glass.
As an aid to fusion cutting of stacked metallic plates without adherence. The cutting is done with an electric arc or oxy-gas torch.
MONS 209521
Reported Applications
. Hydraulic . Vacuum pumps . Heat transfer . Plasticizers . Adhesives . Textile coatings . Surface coatings , Sealants . Printing . Fire retardants and
flame proofing . Carbonless copy paper
EXHIBIT XVII EPA
PCB LEVELS ASSOCIATED WITH VARIOUS PRODUCTS/PROCESSES
XX
Trace
PCB Levels. Percent Ranges
Low Medium High
Pure Form
X X X
X X X X X X
Likelihood of Direct Contact by the General Population
Low Low Low Medium Medium Medium Medium Medium Low
Medium High
HONS 209522
SECTION VII HONS 209523
SECTION VII
THE ENTRY OF PCBs INTO THE ENVIRONMENT AND MANAGEMENT STEPS
In this section the input/output dynamics of PCB consumption in the major end-use categories are examined. Patterns of entry into the environment are defined. Environmental control actions are summarized, and criteria for further management steps are developed.
1. ABOUT 500 MILLION LBS. OF PCBs ARE IN-SERVICE. BASED ON A SNELL LIFE CYCLE MODEL
Rough models of the entry of PCBs into the environment from both open and long-lived contained systems have been developed. notably by Nisbet and Sarofim (13). Continuation of this work has been published by Nelson (38).
(1) Nelson (38) Estimated That The Equivalent of 80% of The Annual Aroclor Sales Was Scrapped In 1970
During 1970 about 58 million lbs. of PCBs became scrap (80% of 73 million lbs.. the 1970 domestic sales of Aroclors).
Nelson (38) distributed this scrappage to principal routes of environmental entry as follows;
- 2 to 4 million lbs. lost to the atmosphere through evaporation from plasticizer applications
- 8 to 10 million lbs. attributed to leaks and disposal of hydraulic, heat ex change end transformer fluids, mostly entering coastal and fresh waters
VII-1
MONS 209524
- about 44 million lbs. attributed to disposal in dumps and landfills in capacitors. plastics and miscellaneous products; Nelson 38) further dis~ tributed this solid waste portion aa follows:
.. 10-20% burned. at various
'
efficiencies and possibly in
conjunction with the produc
tion of highly toxic by-products
such as dichlorobiphenyl furanes
and dioxanes
.. about 2% vaporized
.. long-term environmental storage of the remaining 34 to 39 million lbs. of PCBs in solid wastes in dumps and landfills
Based on correlation of Aroclor type with principal end-use as well as pattern of scrappage, Nelson (38) postulated that prior to Monsanto's elimination of sales for open system applications
- PCBa entering the environment through the air route have been most likely Aroclors 1248 through 1260 from plastics and Aroclor 1242 from burning of refuse containing capacitors.
- PCBs entering the environment through the water route have been most likely Aroclors 1242 through 1260 from hydraulic.lubricant and transformer applications.
- PCBs stored in the environment in dumps and landfills have been most likely Aroclor 1242 from capacitors.
VII-2
HONS 209525
(2) A Life Cycle Model. Developed From Further Evaluation Of Nelson's (38) Assumptions Regarding The Scrappage Rates Of PCBs, Indicates That The Equivalent Of Only
About 26% Of The Annual Aroclor Sales Was Scrapped ]n 1970
. The PCB service life functions in Exhibit XV11I
are the basis of the Snell model.
'
- These functions disaggregate annuel usage.
- Each major end-use category is characterized in terms of
.. PCB scrappage aa percent of annual sales
.. corresponding spproximste in-rservice life of PCB
. Assuming that in-service lives of PCBs in the major end-uses have been and will be reasonably constant, the following information can be generated
- estimates of the total amount of PCBs in-service, based on annual sales figures
- estimates of the amount of PCBs scrapped as a function of time and through the principal channels of entry into the environment, especially where a channel is characteristic of an end-use category
- projection of the disappearance of the current open-system inventory of PCBs in-service
- testing the consequences of various PCB control scenarios after further refinement of the model
Vll-3
HONS 209526
During 1370 about 19 million lbs. of PCBs became
scrap using the Snell model, corresponding to
about 2G%of the annual Aroelor sales. (Nelson (38)
estimated that these figures were 58 million lbs.
and 80V respectively). Entry into the environ
ment probably followed the pattern defined by
Nelson (38), presented in summary form under
1. (1) above.
'
2 to 4 million lbs. to air about 3 million lbs. to water 12 to 14 million lbs. to land
.. roughly 20% burned
.. roughly 80% in long term environmental storage in dumps and landfills
The total smount of PCBs in-service through the end of 1973 was estimated using the procedure exemplified in Exhibit XIX. The table below pre sents in-service estimates by end-use category.
End-Use
PCB Quantity In-Service Through 1973 (million lbs.)
Transformers Capacitors Heat exchangers Plasticizer applications Hydrsulic fluids and lubricants Miscellaneous industrial
applications
205 270
11 insignificant
9 insignificant
Total
495
Assuming continuation of the current pattern of Aroelor sales through 1978, at the end of the next five years essentially no PCBs will be in non-electrical service
Minimizing environmental burden from the roughly 20 million lbs. of PCBs still in non-electrical service is probably unfeasible logistically
Exhibit XX summarizes the historical pattern of PCB channels to the environment.
Vll-4
MONS 209527
2. SIGNIFICANT STEPS HAVE ALREADY BEEN TAKEN TO ENVIRONMENTALLY MANAGE PCBs IN PRODUCTION, CONSUMPTION AND COMMERCE
Major control actions and strategy considerations are summarized below.
(1) The Monsanto Company, The Sole U.S- Producer, Has Led Environmental Control of PCBs
These steps fall into the general categories of process control, product improvement, sales restrictions, establishment of a waste disposal service, and "good will".
Principal reported environmental controls at the existing production facility are summarized in Section V, and in Exhibit V.
Product improvement is represented by Aroclor 1016, a varisnt of Aroclor 1242 and its replace ment in new capacitors. The 1016 material con tains a typical concentration of 0.4% by weight of the higher boiling (more persistent) chlorobiphenyl homologs, whereas the 1242 product contained about 7% of these (16). R6D efforts to find or develop equivalent, but readily biodegradable replacementa for Aroclors in electrical service have not been successful (36) .
Sales restrictions include:
- discontinuation of sales to end-uses other than capacitors and transformers (longlived closed systems)
- restriction on sales to non-electrical manufacturers (36)
- requirement of a letter of intent by pur chasers to follow good manufacturing practices (36).
Vll-5
HONS 209528
. The waste disposal service includes destruction of waste PCB liquids in the incinerator described in Section V and the acceptance of used containers for controlled recycle. The following are key features of the container recycling service
- acceptance by Monsanto
- decontamination by an affiliatedcontractor
- firing of containers
- refurbishing for resale for non-food uses
- incineration by Monsanto of the decontamination solvents
. "Good will" includes general cooperativeneaa and an organizational awareness of product acceptability and stewardship.
- Aa a service to open system customers, the firm has prepared a liat of possible replace ments for PCBs in adhesives and coatings (14) .
- The company has aet up an educational pro gram for customers. showing means for avoiding losses during the handling and use of PCBs (14).
The Market Statistics Suggest That The Great Majority Of Open Svatem Users Of PCBs Have Found Alternatives To This Commodity. But There Has Not Been A Sense Of Urgency To Eliminate PCBs Already In Service
. Countless PCB bearing "open" processes and products currently In use, pre-date the voluntary elimination of sales to open system customers by Monsanto.
- With time, PCBs from these sources will disappear from active usage. This will lead to a corresponding gradual lessening in environmental burden
VII-6
HONS 209529
- There may be appreciable quantities of carbonless copy paper with PCBs in widely distributed, albeit gradually declining inventories (36)
- The literature and limited interviews Indicate that there has not been a sense of urgency on the part of uaere for the controlled replacement of PCB fluids in non-food processing
. The same sources also indicate that PCBs were not handled with greater care in processing than other plasticizers, or analogous materials in the various end-usea
- open system formulation and processing facilities may be still contaminated with PCBs from past practice
- a limited number of facilities may still be processing PCBs from past inventories or imports
- it is reasonable to assume that the general environment of industrial areas will be burdened with a gradually declining input of PCBs from discontinued past practices
(3) The Current Buyers Of PCBs For Capacitor And Transformer Insulation Have Taken Formal Steps Toward Environmental Control
A number of purchasers hsve discontinued the use of these materials (51), including
- Allis Chalmers - Wagner Electric - Esco Manufacturing - Others
VI1-7
HONS 209530
Manufacturers through their industry association, the National Association of Electrical Manufacturers (NEMA), have developed the "Proposed American National Standard Guidelines For Handling and Disposal Of Capacitor - And Transformer-Grade Askar els Containing Polychlorinated Biphenyls, C 107,1 - { ) (16) .
- See Exhibits VIII and IX for excerpts of the principal proposed technical procedures
- The prime users of askarel capacitors and transformers were represented by an indus try delegation, coordinated by the Edison Electric Institute (43)
Nelson (36) reported a case study of environmental losses at a capacitor manufacturing facility before and sfter controls were instituted. See Exhibit XIV. The major sources of PCB losses were
- Aroclor handling and filtration - capacitor degreasing - capacitor rejection
Although askarel capacitors are long-lived closed systems, in use these are universally distributed.
- the feasibility of PCB control in capacitor manufacture can depend on whether or not best available environmental controls for organic chemicals of the same general class are sufficient
- PCB control at the point of capacitor use could represent complex logistics , but the require ment of "turning in" faulty or useless capacitors for central disposal (as in exchange for replace ment capacitors) could be workable
- the feasibility of PCB control in the capacitor disposal phase can depend on
.. whether or not conventional (landfill or other) solid waste disposal practices are suitable
VII-8
HONS 209531
.. the extent to which improper disposal practices, such as poorly controlled burning of capacitors, are significant and can be controlled
. The environmental control of askarel transformers is less complex than that of capacitors
- the number of transformers manufactured annually and already installed is signifi cantly less than the number of capacitors
- PCB control during transformer manufacture is less complex than that during capacitor manufacture because the former is a simpler process
- PCB control during transformer use is expected to be practicable because users are overwhelm ingly industrial, concentrated in the electrical industry and in numbers that can be "traced"
- PCB control in the transformer or waste askarel disposal phase is expected to be feasible for the same reasons
. It has been estimated that the future environmental losses of PCBs from electrical applications can be held below 0.031 of the PCBs In-service (44) with proper control of scraps.
- small losses from product failure in-service would occur
- with time, an increasing portion of askarels will be Aroclor 1016 . This will minimize the entry into the environment of the more per sistent homologs of PCB,
(4) The Control Of PCBs Already In The Environment Is Not Feasible. Except In Highly Localized Situations
. PCBs are universally distributed in the environment, with reported higher concentrations near industrial areas (26).
VII-9
MONS 209532
. Highly localized situations may include
- landfills and open dumps
- some contaminated production facilities (discontinued or on-going production}
- spill sites
'
- some sludges
. While appreciable decontamination activities in the general environment are not feasible, monitoring can indicate hazard as well as record dissipation of PCBa to acceptable levels.
(5) Regulatory Action Can Assure Highly Controlled Use Of PCBs In The Future
. One alternative is to simply ban the production and remaining uses of PCBs in the U ,S.. as in Japan. where need for exemptiona has arisen. The economic impact of such action should be thoroughly investi gated. considering the technological and institutional dependence in the U.S. on askarel type capacitors and transformers
. Another alternative is to establish specific controls such as
- the Food and Drug Administration's actions to prevent PCBs contamination of animal feed, foods, and food packaging materials
- the Environmental Protection Agency's actions to include PCBs on the Toxic Substances List and to promulgate Toxic Effluent Guidelines
- the actions of the U.S. Customs Bureau to monitor FCB imports
- the actions of the Occupational Safety and Health Administration to limit worker ex posures to PCBs
VII-JO
HONS 209533
the actions of the Organization for Economic Cooperation and Development to limit inter national use of PCBs
.. through exchange of statistical data
.. through controls on production; distribution, imports/exports
.. through controls on end-uses, such as limitstion to electrical and other systems where non flammability is essential
A logical regulatory extension of the pattern of recent voluntary controls is
- formal banning of the sale or purchase of PCBs for non-electrical uses, and the granting of exemptions on a case-by-case basis
- formal sanctioning of the National Standard Guidelines For Handling and Disposal of Capacitor - And Transformer - Grade Askarels Containing Polychlorinated Biphenyls
- establishing an enforcement mechanism that also applies to importing of PCBs
Vfl-U
HONS 209534
Historical PCB End-Use Category . Transformers
. Capacitors
. Heat exchangers . Plasticizer
applications
. Hydraulic fluids and lubricants
Miscellaneous industrial applications
Annual Sales Outlook 10% growth
6% growth
No sales No sales
No sales
No sales
Historical PCB Scrappage As Percent of Annual Sales
3 - 4% 8%
20% 60%
25%
90%
EXHIBIT XVIII EPA
PCB SERVICE LIFE FUNCTIONS
Corresponding In-Service Life of PCBs, Years
Remarks
30 Askarel transformers have 30 year or longer lifetime (45. 54)
12 Capacitors life in electric utility service is about 20 years (45) . This is about 10 years in lighting use (45) . Capacitors are sometimes scrapped as part of the parent product, such as lamp ballasts.
5
1.7 Roughly 15% vaporization is considered during service life (48). Plastics have a short useful life.
4 In 1968 about 30% of the annual usage of indus trial lubricating oils and about 20% of the annual usage of hydraulic fluids were waste (49)
1.1
MONS 209535
EXHIBIT XIX EPA
EXAMPLE OF THE USE OF PCB SEHVICE LIFE FUNCTIONS: ESTIMATE OF CAPACITOR PCBs IN-SERVICE
The in-service life of PCBs in capacitors is estimated to be about 12 years, overall. See Exhibit XVU1.
The table below presents Aroclor sales during the last 12 years for capacitor applications.
Year
Sales of Capacitor Aroclors. Million Lbs.
1973 1972 1971 1970 1969 1968 1967 1966 1965 1964 1963 1962
24.0 17.1 14.1 26.7 25.0 29.6 29.7 28.9 23.7 19.5 15.6 15.4
270
Roughly 270 million lbs- of PCBs are in capacitor service through the end of 1973-
Refined estimates could be obtained through consideration of the typical life cycles of the different types of askarel capacitors with corresponding disaggregation of Aroclor sales data.
MONS 209536
Historical PCB End-Use Category
. Transformers
. Capacitors
. Heat exchangers
. Plasticizer applications
. Hydraulic fluids and lubricants
. Miscellaneous industrial applications
. All categories: ratio of importance based on Nisbet and Sarofim's work (9)
EXHIBIT XX EPA
HISTORICAL PATTERN OF PCB CHANNELS TO THE ENVIRONMENT
Interface With The Environment Of Scrap PCBs
Air
Water
Land (dumps, landfills, etc.)
X XX XX
X XXX
X
XXX
X
XX XXX
X XX XX
X XXX
1 2 10
Note: XXX = Principal channel; XX == secondary channel; X = non-negligible channel
MOWS 209537
SECTION VIII MONS 209538
SECTION VIII
BIBLIOGRAPHY
1. Interdepartmental Task Force on PCBs Report 1TF-PCB-72-1; Polychlorinated Biphenyls and the Environment. May 1972. 189 pp. (COM-72-10419).
2. Quinby, Griffith E.: Polychlorobiphenyls (PCBs) and Related Chlorophenyls: Effects on Health and Environment. 1. Bibliography -- 1881-1971. Oak Ridge, Tennessee; Oak Ridge National Laboratory (Report ORNL-E1S-72-20), Toxicology Infor mation Response Center Report TIRC-1; 1972. 140 pp. PB-209, 944.
3. Department of Agriculture Ad Hoc Group on PCBs; Agriculture's Responsibility Concerning Polychlorinated Biphenyls (PCBs). Washington, Department of Agriculture, 1972. 39 pp.
4. Crump-Wiesner, Hans J. et al.: Distribution of Polychlorinated Biphenyls in the Aquatic Environment, Washington, United States Geological Survey, 1972. 24 pp.
5. Fine, Sam D.: Final Environmental Impact Statement Rule Making on Polychlorinated Biphenyls. Washington, Department of Health, Education, and Welfare, Food and Drug Administration. 1972. 29 pp.
G. Criteria Document For PCBs. Unpublished. Environmental Pro tection Agency, 1973.
7. Council on Environmental Quality: Toxic Substances. Washington. Government Printing Office, 1971. 25 pp.
8. Jay, Pierre: PCB - Uses in Askarel For Electrical Industry. Solna, Sweden; National Swedish Environment Protection Board; 1970. 25 pp.
9. - National Environmental Research Center: Position Paper on Poly chlorinated Biphenyls (PCBs). Washington. Environmental Protection Agency. 1973. 170 pp. Unpublished.
V11I-1
HONS 209539
10. Rlsebrough, Robert: More Letters In the Wind. Environment 12:16-26, January-February, 1970.
11. Hubbard, H.L.: Chlorinated Biphenyl and Related Compounds. IN: Klrk-Othmer Encyclopedia of Chemical Technology. Second Edition. Volume S. New York, Interscience Publications. 1964. pp, 289-97.
12. Monsanto Company: Status Report to the Interdepartmental Task Force on PCBs. Presented May 15, 1972. Washington. ca. 100 pp.
13. Nisbet. I.C.T. and Sarofim, A.F.: Rates and Routes of Transport of PCBs in the Environment. Presented at International Scientific Meeting on PCBs. Quail Roost Conference Center, Rougemont, North Carolina. December 20-21, 1971,
14. Anon.: Pollution Cop's Lot Not 'Appy.' Chemical Week 108: 19-20, April 21, 1971:
15. Weiss. Hans K. (Foster D. Snell, Inc.): Market Study of Chlor inated Diphenyls, Confidential Report, 1966.
16. National Electrical Manufacturers Association: Proposed American National Standard Guidelines for Handling and Disposal of Capacitorand Transformer - Grade Askarels Containing Polychlorinated Biphenyls, C 107.7-( ). NEMA Official Standards Proposal. Pub. Nos. CP-P1-1973 and TR-P6-1973. January 25. 1973. 23 pp.
17. Department of the Interior. Water Resources Scientific Information Centsr WRS1C 73-201: PCB in Water, a Bibliography. (96 references with abstracts). January 1972. 144 pp.
18. Koppers Co,, Inc., Tar Products Division: Halowax Chlorinated Naphthalenes. No date,
19. Broadhurst, Martin G.: Use and Heplaceability of Polychlorinated Biphenyls. Environmental Health Perspectives 81-102, October 1972. National Bureau of Standards Report COM-72-51054..
20. Vos, J. G. et al.: Identification and Toxicological Evaluation of Chlorinated Dlbenzofuran and Chlorinated Naphthalene in Two Commercial Polychlorinated Biphenyls. Food and Cosmetics Toxicology 8:625-33, 1970.
V11I-2
HONS 209540
21. Zitko, V. (Fisheries Research Board of Canada): Absence of Chlorinated Dibenzodioxins and Dibenzofurans from Aquatic Animals. Bulletin of Environmental Contamination and Toxicology 7:105-10, 1972.
22. Anon.: Who Have Been the Users (Industrial) of Dangerous Poly
chlorinated Biphenyls? Chemical Engineering 79: 37, January 10,
1972.
'
23. Anon.: Multiple Hearth Incineration. Water Q Wastes Engineering 9: 46, December 1972.
24. Anon.: Monsanto Will Take Steps to Prevent Environmental Buildup of PCBs. Chemical S Engineering News 48:11, July 20, 1970.
25. Anon.: Environmentally Hazardous Polychlorinated Biphenyls Are Even More Widespread----- Chemical Engineering 79:18, October 2, 1972.
26. Anon.: Monsanto Releases PCB Data. Chemical fi Engineering News 46: 15. December 6. 1971.
27. Edwards, R.: The Polychlorobiphenyls, their Occurrence and Significance. A Review. Chemistry and Industry 47: 1340, 1971.
28. Anon.: Chemical Pollution. Polychlorinated Biphenyls. Science 175: 155, 1972.
29. Anon.: Research Heightens Concern Over PCBs. Chemical 6 Engineering News 50; 27-8, April 17, 1672,
30. Anon.: Prevalence. Impact of PCBs Probed. Chemical 6 Engineering News 50: 28-30, September 11, 1972.
31. Anon.: An International Agreement Limits PCB Use. Chemical 6 Engineering News 51; 2-3, February 26, 1673.
32. Carnes. R.A. at al.: Polychlorinated Biphenyls in Solid Waste and Solid-Waste Related Materials. Archives of Environmental Contamination Toxicology 1: 27-36, 1973.
33. Tas. Albert C. and de Vol, R. H.: Characterization of Four Major Components in a Technical Polychlorinated Biphenyl Mixture. Environmental Science S Technology 5: 1216-18, 1971.
VIII-3
MONS 209541
34. Gustafson, Carl G.: PCBs - Prevalent and Persistent. Environmental Science 6 Technology 4: 814-19, 1970.
35. Polychlorinated Biphenyls - Contamination of Animal Feeds. Foods, and Food Packaging Materials. Federal Register 38: 18096-104, July 6, 1973.
36. Papageorge, W.P. (Monsanto Industrial Chemicals Company):
Personal Communication. December 7, 1973.
37. Papageorga, W.P. (Monsanto Industrial Chemicals Company): Polychlorinated Biphenyl (PCB). A Presentation to the Effluent Standards and Water Quality Information Advisory Committee, November 29, 1973. 7 pp.
36. Nelson, N.: PCBs - Environmental Impact. A Review by the Panel on Hazardous Toxic Substances. Environmental Research 5; 249 362, September 1972.
39. United States Tariff Commission, TC Publication 601: Imports of Benzenold Chemicals and Products. United States General Imports of Intermediates Dyes. Medicinals, Flavor and Perfume Materials, and other Finished Products Entered in 1972 under Schedule 4, Part 1, of the Tariff Schedules of the United Ststes. Washington. U.S.T.C., 1973. 98 pp.
40- Customs Bureau Personnel in New York and Washington: Personal Communications, December 1973.
41. Tse. F. Y. et al.: Review of Dielectric Media - Liquid Insulation. Insulation/Circuits, January 1971.
42. Industry Statistics on Electric Power Equipment. Predicasts, Quarterly Issues 47-54, 1972 and 1973.
43. Cawley, J. (Edison Electric Institute, New York): Personal Commun ication, November 28, 1973.
44. Boqulst, E.R. IWestinghouse): The Need for Continued Use of Polychlorinated Biphenyls as Electrical Insulating Liquids. Pre sented to the National Industrial Pollution Control Meeting,
- January 10, 1972. IS pp.
V1II-4
HONS 209542
45. . McAllister, John F. et al. (General Electric Co.): Benefits of PCB Use. Private Communication to Dr. Edward J. Burger, Jr., Executive Office of the President, Office of Science and Technology December 30, 1971. 36 pp.
46. Anon.: Foreign Companies Exporting Transformers to the United States. Electrical World. June 29, 1970, p. 59.
47. Monsanto Chemical Co. , Organic Chemicals Division Technical Bulletin O/PL-306A: Aroclor Plasticizers. No date.
48- Anon.: Jepanese Develop Method to Decompose PCB. Chemical Marketing Reporter 203:27, April 9, 1973.
49. National Industrial Pollution Control Council, Electric and Nuclear Sub-Council: The Use and Disposal of Electrical Insulating Liquids, Sub-Council Report. Washington, N.I.P.C.C., 1971. 22 pp.
50- Livltz, N. et al.: Control Technology for Polychlorinated Biphenyls (PCBs). Argonne National Laboratory, report to Control Systems Laboratory, EPA, (April 1973).
51. Electrical Industry, Selected Sources: Confidential Communications, December 1973.
52. Department of Commerce: U.S. Industrial Outlook 1974 with Projections to 1980. Washington, Department of Commerce, 1973. p, 349.
53. Current Industrial Reports; Fluorescent Lamp Ballasts, Second Quarter 1973. Department of Commerce Series MQ-36C (73)-2, August 1973.
54. Onlshi, Harry (Commonwealth Edison Company, Maywood, Illinois); Personal Communication. December 19, 1973.
55. Salomon, Paul (Yates Manufacturing, Chicago): Personal Commun ication, December 19, 1973.
V1I1-S
HONS 209543
EXHIBIT Vill (4) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
2. Liquid
Operating procedures should be such as to minimize or eliminate contact with aakarels. Use of eye protection is recommended. The use of porous gloves which can absorb and retain askarals is to be avoided. Barrier creams or re sistant gloves should be used if contact is unavoidable. Use of enclosed transfer and handling equipment, processing equip ment. and mechanical washers reduces direct contact.
Safety glasses with side shields or a face shield should be worn when handling aakarels.
D. Manufacturing Housekeeping
Manufacturing equipment and operating procedures should safe guard against loss of askarals to the environment through proper containment and disposal procedures.
Enclosed systeme of sealed piping, properly gasketed joints, valves, containers, and processing chambers should be used for any portion of the operation where askarel temperatures may exceed S5C. Enclosure should preferably extend to all other portions of the system Insofar as practicable.
Containment provisions should be established around all askarel proceaslng areaa to ensure against Inadvertent loss to sewer systems by spillage, leakage, or other uncontrolled conditions or events.
Spills of askarel should be removed promptly by means of absorptive material, such as sawdust, or trapped and removed by pumping or other suitable means.
Waste fluids containing askarel not suitable for reconditioning or reuse should be collected (by means of traps, drip pans, trsys, etc.) from the vsrious parts of the manufacturing and processing area (including washers or other cleaning devices). Disposal should be made in accordance with Part V of this section.
Wiper rags, clothing and other extraneous materials saturated with aakarels should be collected within the containment area for properly controlled laundering or disposal (see Fart V of this section).
HONS 209544
EXHIBIT VIII IS) EPA
EXCERPTS FHOM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
E, Disposal of Askarel Wastes
Methods for disposal of liquids and saturated solids generated by the manufacturing operation should be in accordance with those outlined in Part V of this section and should include (but not be limited to) the following wastes:
1. Contaminated liquid askarel which is unsuitable for reclaiming as a dielectric fluid.
2. Liquid askarel from solvent operations or water/ detergent type washers.
3- Saturated earth or other absorbent media from filtering operations.
4. Saturated sawdust or other absorptive materials from spills.
5. Saturated filtera from vapor control devices and other filters.
6. Ssturated wastes (paper, rags, etc.).
7. Saturated, spent gasket materials.
8. Askarel-contaminated vacuum pump oils. 9. Askarel-contaminated steam jet vacuum system
condensates.
F. Miscellaneous Procedures
1. Spills by leakage from finished capacitors should be cleaned up promptly by means of absorbent media which should then be moved to containers provided for that purpose within the containment area and later disposed of properly.
HONS 209545
EXHIBIT VIU(6) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued) 2. Askarel wastes should never be disposed -of down effluent drains or sewers. The utmost care must be exercised to prevent accidental loss by these avenues to the environment. 3. Capacitors failing tests or otherwise designated for disposal must be controlled and handled in accordance with the intent of the procedures above, finally being disposed of by one of the means outlined in Part V of this section.
HONS 209546
EXHIBIT VIII (7) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
IV. CONTROL OF WATER EFFLUENTS
...Existing drain systems in capacitor manufacturing plants are probably contaminated as a result of past practices, and askarel traces may continue to show up in effluent streams for some time. However, the level should continue to decrease with the proper containment of askarel wastes and no further discharges into drain systems. Other sections of this report provide that no askarel wastes of any kind be disposed of in sny water effluent streams and that accidental spills be prevented from getting into such streams.
A. Concentration Limits
The 1972 EPA proposals are to keep PCB levels in rivers and lakes below 0.01 parts per billion. Plant effluent streams should be managed and controlled in a manner consistent with this goal,
B. Monitoring Streams
On a regular basis consistent with plant situations, all effluent streams should be analyzed. The procedures for per forming the necessary analyses are contained in Section S, Analysis of Water and Sediment for Polychlorinated Biphenyls. This procedure or its equivalent should be used,
C. Methods For Minimizing Effluent Stream Contamination
The ideal approach is to totally isolate all effluent streams that could be contaminated with askarels during manufacturing processes and prevent them from being discharged from the plant. Carbon adsorption, limestone beds, and solvent extraction are techniques which can be applied to reduce the askarel content of effluent streams. These techniques may be most useful in cleaning up water used in plant processing and to permit re cycling ,
HONS 209547
EXHIBIT V1U (6) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
V. SCRAP DISPOSAL PROCEDURES The manufacture and use of capacitors involve processes which
produce askarel-saturated solids and liquids containing or composed entirely of askarel. which should be disposed of as wastes. Specific sources of these materials appear throughout thia document but may be placed into three categories:
1. Capacitor units impregnated with askarel, production and field rejects.
2. Manufacturing process liquid wastes containing askarel,
3. Solid waeta purposely or accidently eaturated with askarel. Disposal should be done in a manner which is consistent with proper concern for the environment and which minimizes any release of askarels to the environment.
A. Disposal of Capacitor Units Scrap capacitor units can be generated during manufacturing
processes or during field service, Production rejects are those capacitore which are rejected
after the impregnation process in the course of production by the capacitor manufacturer. They may be rejected for mechanical or electrical reasons, or because of obsoleecence.
Field rejects are those units which are rejected or which, for other reasons, are to be scrapped after shipment from the plant where they were manufactured.
HONS 209548
EXHIBIT Vin (9) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
l. Production Rejects
Rejected capacitors in capacitor manufacturing plants represent a concentration of sskarel. It ia important that their disposition be made in a manner consistent with proper concern for the environment. Therefore, capacitors should be disposed of only in supervised dry landfill sites which meet all applicable State requirements.
Care should be exercised to insure that no loss of liquid will occur during transportation to the disposal site.
Incineration of scrap capacitors in facilities designed to accept such solids should provide an alternate means of disposal as such services become available in the future.
2. Field Rejects
Small capacitors (defined aa containing less than 2 pounds of sakarel) are practically always used as components in othsr electrical or electromechanical equipment. Typical examples of large quantity usage of such capacitors are in fluorescent lamp ballasts and residential sir conditioning equip ment. Failure of such capscitors may result in scrapping of the device of which it is a part (ss in a fluorescent bsllast) or re placement and scrapping of the individual capacitor (aa in a room sir conditioner). However, the majority of such capacitors do not fail in service, but are scrapped as a result of wearing out or obsolescence of the devices in which the capacitors sre used as components. Thus, the matter of disposal is characterized by a low concentration of amall quantities of askarel throughout the country and, indeed, throughout the world. Fortunately, the nature of the devices and equipment in which such capacitors are used is such that they are normally disposed of in dry land fills as a matter of convenience. Since it is impractical at present to exercise any meaningful control over the disposition of the bulk of such devices and equipment, it ia imperative that aakarel used for Impregnating small capacitors be limited to the recently intro duced type which contains a typical concentration of 0.4 percent
of the higher boiling homologs.*
Monsanto Method T-02302
HONS 209549
EXHIBIT VIII (10) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
Large capacitors (those incorporating more than 2 pounds of aakarel) should be disposed of according to the procedure for production rejects. See par. A.l.
B. Disposal of Liquid Wastes
All waste askarel or liquid wastes containing aakarel should be disposed of in accordance with one of the following procedures:
1 Incineration
Present knowledge indicates that proper Incineration must involve a suitable balance between dwell time and temperature in the incinerator plua oxygen availability and. finally, suitable scrubbers to remove the HC1 which will be formed: e.g., (1) 2-second dwell time at 2000? and 3 percent excess oxygen in stack gas; (2) 1 1/2-second dwell time at 2700F and 2 percent excess oxygen in stack gas.
These facilities should meet the applicable requirements of the State in which they are located and should control effluenta within the limits set forth in this document.
2. Toxic and Hazardous Waste Disposal Sites
Certain landfill sites have been classified by State and Federal Governments as suitable for the disposal of toxic and hazardous liquids. Where such approved sites exist, they may be used for the disposal of liquid wastes described in this doc ument. (See Section 4).
3. Packaging and Shipment
a. Transportation to the disposal facility should be in containers which will prevent leakage and accidental loss of askarel to the environment.
b. Containers should be labeled as to contents and precautions relative to loss to the environment.
HONS 209550
EXHIBIT vm (11) EPA
EXCEHPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
c. Containers used for this purpose should not be used for any other materials or retired from service until they are completely cleaned. Any solvents used in cleaning these containers will be contaminated with askarel and should be disposed of according to the same procedures herein described.
C. Disposal of Solid Wastes All solid wastes which have been saturated with askarel
should be disposed of by the following procedure: 1. The saturated wastes should be placed into leak proof containers and transported to a supervised dry landfill site meeting State requirements. Alter natively, they can be disposed of by incineration in State-approved facilities. 2. Solid absorbents used for spills csn be disposed of uncontained in the supervised dry landfill site: transport to the site should be in closed containers. Alternatively, incineration can be used In accordance with par. B (See Section 4 lor facilities).
HONS 209551
EXHIBIT VIII (12) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTHOLS (continued)
VI. LABELING
Capacitor units vary greatly in size and in end use or application. Small capacitor unlta are frequently applied as a component of another piece of equipment such as a fluorescent lighting ballast, a roadway or area lighting luminaire; a motor, etc. In such applications a label on the capacitor unit referencing approved disposal procedure would not normally be visible when the piece of equipment is disposed of.
For the foregoing reasons the method of providing disposal instruc tions for small capacitors and large capacitors is treated separately.
1. Small Units (incorporating Leaa Than 2 Pounds of Askarel) Small capacitors are defined as those which contain aakarel
in quantities up to about two (2) pounds each and in which the free liquid does not exceed 0.4 pounds. They are hermetically sealed in metallic cases. Such capacitors are applied aa a com ponent of a larger piece of equipment. Attaching a label to auch equipment referencing this Guideline or describing disposal pro cedures would be of limited practical value. 2. Large Capacitor Units (Incorporating More Than 2 Pounds of
Askarel) The capacitor manufacturer should affix a label in a conspicuous place, referencing this document or describing disposal procedures, consistent with it.
HONS 209552
EXHIBIT yin (13) EPA
EXCERPTS FROM NEKA'S PROPOSED ENVIRON MENTAL CONTROLS (continued)
SECTION 3 TRANSFORMER GUIDELINES
GENERAL GUIDELINES
A, Definitions - Types of Transformer Askarels
The term askarel generally describes a broad class of non flammable synthetic chlorinated hydrocarbon Insulating liquids widely used in transformers, reactors, and accessory equipment operated at power frequencies. Askarels of various compositional types are in use (for the general properties and types, aee ASTM Specification for Chlorinated Aromatic Hydrocarbons (Askarels) for Transformers, D 2283).
The following trademarks are used by electrical manufacturers to designate the askarels used in their products:
. Asbestol . Chlorextol . Inerteen . No-Flamol . Pyranol . Saf-T-Kuhl
B. Safety Precautions
1. Vapors
Breathing vapor or fumes from heated askarels should be avoided. Provisions shall be made for adequate ventilation and regulation of manufacturing operations to avoid open ex posure of hot askarels (55C or higher). The gases produced when askarel is decomposed by very high temperatures (such as that of an electric arc) in the presence of air or organic
HONS 209553
EXHIBIT VIII (14) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
insulating materials contain a high percentage of hydrogen chloride, and small percentages of other gases.* If exposure to high concentrations of askarels or its arced products is necessary under emergency conditions, an approved gaa mask of the organic canister-type or self-contained breathing apparatus must be worn. Such exposure should be under the surveillance of other pereonnel capable of reecue in case of accident. If the odor of askarel or its arced products is detected by the person wearing protective equipment, he should Immediately go into fresh air.
2. Liquid
Operating procedures should require avoidance of contact with any askarels. The use of porous gloves which can absorb and retain askarels is to be avolced. Resistant gloves and aprons of the neoprene, polyethylene, viton type should be used if con tact is unavoidable. In case of spillage on the clothing, the clothing should be removed as soon as practical, the skin washed and the clothing laundered.
Safety glasses with side shields or a face shield should be worn when handling askarels.
Hands should be washed with warm water and soap before eating, drinking, smoking or using toilet facilities.
C. Transport Container Marking
Any container such ss tank cars, tank trucks, drums, cans, etc., used to transport transformer aekarele. new or used, should be labeled ...
D. Receiving. Handling and Storage of Askarels
Askarels are shipped in tank cars, tank trucks, steel drums, metal cans and test sample containers. When received, all containers should be inspected for leaks.
HONS 209554
EXHIBIT VIII (15) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
1. Storage Tanks
Storage tanks should be erected ao that Inspection can be made for leaks or spills. Construction should be such that inadvertent leakage or spills are prevented from reaching streams and sanitary or storm sewers.
2. Tank Cars and Tank Trucks
All bulk shipment equipment should be Inspected for leaks Immediately upon receipt. Drain pans must be provided to pre vent spillage from unloading hoses and connections. Askarel liquid collected in drain pans should be placed in "SCRAP ASKAREL" drums for disposition.
3. Steel Drums. Cans, and Test Sample Containers
On delivery, all such shipments should be carefully in spected for leaks. The containers should be stored indoors in an area especially selected for this purpose. A curb should enclose the srea to provide a basin for containing the askarel from one or more containers should the containers be damaged. The area must not have a drain which is connected to a sanitary or storm sewer.
If an indoor storage area is not possible, the containers should be stored under a lean-to.
E. Water Effluents - Sampling. Concentration Limits and Analytical Procedures
...Existing drain systems from manufacturing plants, repair shops and installation sites may be contaminated as a result of past practices.
1. Concentration Limits
The 1972 EPA proposals are to keep PCB levels in rivers and lakes below 0.01 parts per billion. Plant effluent streams should be managed and controlled in a manner consistent with this goal.
HONS 209555
EXHIBIT VIII (16) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
2. Monitoring Streams
All plant effluent stream a should be monitored on a regular basis, consistent with plant situations. The pro cedures for performing the necessary analyses are contained in Section 5. "Analysis of Water and Sediment for Polychlorinated Biphenyls." This procedure or its equivalent shall be used.
3, Methods for Minimlilng Effluent Stream Contamination
The ideal approach is to totally isolate all effluent streams that could be contaminated with askarela during manufacturing processee and prevent them from being discharged from the plant.
F. Disposal Procedures and Services
1. Sources of Materials Requiring Special Handling and Disposal Procedures
Liquids containing PCBs and solids containing or con taminated with PCBs may be obtained from any of the following sources: transport containers, transformer manufacturing pro cesses. in-test failures, liquids contaminated beyond reclamation, in-service transformer leake and failures, askarel-filled trans formers scrapped for any reason, etc.
2. Classification for Disposal of Materials Containing PCBs
In general, there are three types of materials requiring disposal: liquids, burnable solid materials containing PCBs and nonburnable solid materials contaminated with PCBs.
a. Liquids. Liquids containing PCBs requiring dis posal by high-temperature incineration may consist of the following:
(1) PCBs contaminated with mineral oil.
(2) Mineral oil contaminated with PCBs.
HONS 209556
EXHIBIT HI (2) EPA
END-USES OF AROCLORS (continued)
End-Use
1016
Miscellaneous Industrial
. ashesives . wax extenders . dedusting agents . inks . cutting oils . pesticide extenders
1221 X
1232 X
1242
X X
1248 X
1254
X X X X X X
1260 X
1262
1268 X
Note: Source:
X denotes use of a given Aroclor in a specific end-use, while XX denotes principal use References 16. 36. 37. 38
HONS 209557
SECTION V
HONS 209556
SECTION V
MANUFACTURING PROCESSES
The basic United States patents for the manufacture of chlorobiphenyls are . U. S . 1.692.397 and 1. B92,39B (December 27. 1932). R. L. Jenkins (to Swann Research. Inc.: reassigned to Monsanto Chemical Co.). . U.S. 3.029.295 (April 10. 1982), Robert Thermet and Ludovic Farvi (to Societe d1 Electro-Chimle D'Electrometallurgie et dea Acieriea Electrlques d' Ugine). . U.S. 1.692,400 (December 27. 1932), R. L. Jenkins and J. A. Sikarski (to Swann Research. Inc.; reassigned to Monsanto Chemical Co.) ,
For a digest of selected process patents including recent developments see Exhibit IV. 1. THE MANUFACTURE OF FCBs IS NOT A COMPLEX PROCESS
PCBs can be prepared by chlorinating biphenyl with anhydrous chlorine in the presence of iron filings or farric chloride as catalyst (11. 34).
. The product is a mixture of several PCBs snd can be purified and fractionated by distillation
. The by-product is hydrogen chloride, which is neutralized before distillation
. The degree of chlorination is principally determined by the time of contact of biphenyl with anhydrous chlorine: 12 to 36 hours usually
. Reaction temperature is about 150C. and pressure is near atmospheric
V-l HONS 209559
. The degree of chlorination Is measured by
- the specific gravity of the mixture, or
- the ball and ring eoftenlng point when the product is more viscous
. Overall, a batch or semi-continuous cascade process can be used.
. These processing fundamentals are featured both in U.S. and Western European installations.
Currently There Is Only One Known Commercial Scale PCB Production Installation In The U.S.
This facility is the William G. Krummrich plant of the Monsanto Industrial Chemicals Co. at Seuget, Illinois. The facility is specifically designed for chloroblpheny Is produ ction
The technology is not complex and other chemical firms snd laboratories in the U.S. have the technical potential to produce PCBa
Process flow in the Krummrich plant is summarized in Exhibit V.
- reported yields are high. 97\ or better (36)
- there are 6 reactors, 3 batch and 3 cascade
- batch size is about 2,500 gallons
- a new distillation column was installed in 1371 at an estimated cost of almost one million dollars (37)
.. the gas fired unit enables production of Aroclors with minimized frectlona of the highly chlorinated, persistent material
V-2 HONS 209560
-. the heel cut residues, representing about 2% of throughput, are drummed, diluted and incinerated
- transformer Aroclors can be diluted to 60-70% PCB with chlorobenzenes before shipping
- overall, the process hsa been simplified (except for environmental controls). since fewer Aroclors are manufactured Including elimination of flaked product
Monsanto Has Reported Significant Environmental Controls At The Krummrich Plant
In Exhibit V a summary ia provided of these controls
The in-house goal has been reduction of PCBs in water discharges to less than one pound par day (36).
The goal for air emissions is also less than one pound per day (36).
An incinerator was erected at Sauget to process both Monsanto's own wastes and as a service to industry.
- the unit, costing $1,500,000, is sized to process about 10 million lbs. per year (14).
- controlled destruction takes place 0 2400F. 0 2% excess O , over 1.5 sec. under an oper ating permit from the Illinois EPA (36).
- exhausts are passed through a high-energy venturi scrubber, then a packed column with weak muriatic acid; exhausts are monitored as well as discharges of neutralized scrubber liquor (36).
- the service charge is 3 per lb. (14, 36).
- there is a current backlog of roughly 250.000 lbs. of material to incinerate and about 20 million lbs. have been destroyed to date (36).
- the company no longer reprocesses contaminated materials
HONS 209561 V-3
2. HISTORICAI-I.y AROCLORS HAVE BEEN SHIPPED IN A FASHION SIMILAR TO ANY OTHER COMMODITY The liquid chlorinated biphenyls have been packed and shipped in galvan-
ized-steel drums or in tank cars constructed of nonrusting metals such as aluminum or tin-coated metal. The resinous products have been packed and shipped in open-top galvanized-steai drums, snd the high-melting solid products are packed and shipped in bags. The railroad shipping classification is Resin Synthetic NOIBN.
Exhibit VI summarizes the historical shipping practices based on the description in Monsanto's technical bulletin on plasticizers (47) .
It is reasonable to assume that the containers associated in the paat with the distribution of Aroclora to Monsanto's open system customers have been a significant, but novr declining, solid waste source of the environmental burden of PCBa.
Currently, Monsanto emphasizes the use of consigned tank cars for distribution to its 25-30 remaining customers, capacitor and transformer manu facturers (36) . Shipping in 55 gallon steel drums still takes place for "topping" purposes. Exhibit VD is a sample of the type of label used for currently marketed Aroclors. providing explicit instructions for safeguards and usea.
The National Electrical Manufacturers Association (NEMA) haa developed standard guidelines for shipping and handling of Aroclors. See Exhibits VUI and IX.
HONS 209562 V-4
3, THERE IS EVIDENCE OF RESEARCH AND DEVELOPMENT ACTIVITY
TO CONTROL SPEN'TPCBs
~
The Monsanto Incinerator la evidence of this, featuring a proprietary John Zink burner design (36) .
Envirotech Corporation (23) reported that PCBs can be almost totally decomposed in multiple hearth Incineration.
. A recent research project showed that PCB (Therminol FR-1) in waste sludges can be over 99.9% decomposed in a BSP multiple hearth furnace when operated at an exhaust gas temperature of 1100F.
. The study shows that multiple hearth inciner ation can achieve more efficient PCB destruction in combination with sewage aludge than other types of incineration methods.
. A BSP furnace operating in the normal 1509-1700F. range but with an exhaust gas temperature of only U00F. can decompose 99.9% of PCB in waste sludges 500F. or more lower than previous norms.
. The majority of the heat required in a BSP furnace is normally supplied by the organic content of the waste sludges and the considerably lower exhaust temperature in the BSP furnace allows fuel savings of 60% in removing PCBs from the environment.
A Koochl University team In Japan has developed a caustic soda solution to completaly decompose polychlorinated biphenyl (48) .
. High pressure is said to turn the chlorine into aodlum chloride within a short time.
. A pilot plant capable of decomposing 30 liters/hr. of PCB will be completed In 1973 at Koochi University and the group will continue experiments, also using alcohol and other solvents.
HONS 209563 V-5
EXHIBIT IV (1) EPA
PATENT DIGEST
PROCESSES FOR THE PREPARATION OF PCBs
'
3.717.685 February 20. 1973 Russell G. Hay, Vincent A. Notaro, Charles M. Selwitz Gull Research 6 Development Company PROCESS FOR PREPARING CHLORINATED AROMATICS
A process for preparing a chloroaromatic compound which involvea heating an aromatic compound in the presence of a nitrate ion. a nitrite ion, NO or N02, HCl, water, oxygen, a strong acid and a paraffin or a cycloalkane.
3,717,884 February 20. 1973 Vincent A. Notaro, CharleaM. Selwitz Gulf Research 8 Development Company PROCESS FOR PREPARING CHLORINATED AROMATICS
A process for preparing a nuclear polychloro alkyl aromatic compound which involves heating an alkyl aromatic In the presence of a nitrate ion, a nitrite ion, NO or N02, HCl, water, oxygen and a strong acid, wherein the molar ratio of HCl to aromatic compound la initially at a level of about 4; 1 to about 10:1 and auch ratio is maintained at approximately such level during the course of the reaction.
3,655.523 April 11, 1972 Harold O. Seeburger, Lee H. Horsley The Dow Chemical Company METHOD FOR SEPARATING A 2- AND 4-CHLOROBIPHENYL FROM THE CORRESPONDING HYDROXY BIPHENYL COMPOUNDS
2-Chlorobiphenyl, 4-chloroblphenyl or mixtures thereof may be separated from a mixture with the corresponding hydroxybiphenyl compound by adding to the mixture of such compounds an azeotropic agent which is a glycol, glycol monoalkyl or phenyl ether, glycerol, glycerol alkyl ether, alkanolamlne or dialkylenetriam In e having e boiling point within about 45C. of the helobiphenyl compound at atmos pheric pressure, and then fractionally distilling the mixture thus formed at a pressure of up to about 200 mm. Hg. absolute.
HONS 209564
EXHIBIT IV (2) EPA
PATENT DIGEST (continued)
3.547.790 December 15. 1970 Bobby F . Dannels and Alvin F . Shepard Hooker Chemical Corporation AROMATIC CONDENSATION PRODUCTS
'
A process for producing aromatic condensation products comprises passing an electric current between a cathode and an anode in contact with liquid phase hydrogen fluoride, wherein the hydrogen fluoride is also In contact with an aromatic compound having a hydrogen atom substituted In at least one position of the aromatic ring, The polymer products have excellent heat resistance and electrical insulation propertiea and can be coated on other types of polymers to modify the surface characteristics thereof. The polymers can be converted to sulfonated polymer products.
3.539,622 November 10, 1970 Richard F. Heck Hercules Incorporated PROCESS FOR PRODUCING DIARYL COMPOUNDS
'
A process for producing a diaryl compound which comprises an aryl mercuric salt In which the aryl group contains a benzene ring to which the mercury Is directly attached with a palladous salt at a temperature In the range of 20 to 150C.
3,145.237 August 16, 1964 Robert van Helden, Govert Verberg. and Bob Balder Shell Oil Company POLYNUCLEAR AROMATIC COMPOUNDS
The process for the intermolecular condensation of aromatic compounds, which comprises contacting an aromatic compound having a labile hydrogen atom attached to an aromatic nucleus, in liquid phase, with a salt selected from the group consisting of the salts of the palladium and platinum group metals with an acid selected from the group consisting of mineral acids, aliphatic monocarboxylic acids and sulfonic acids, under substantially anhydrous conditions, at a temperature of from about 40 to 200C.. in the presence of a member of the group consisting of the oxides and salts of the alkali metals and alkaline earth metals.
HONS 209565
EXHIBIT IV (3) EPA
PATENT DIGEST (continued)
3,072,728 January 8, 1963 Milton Kosmin and Richard L. Wasson Monsanto Chemical Company METHOD OF PREPARING HALOGENATED DIPHENYL COMPOUNDS
A process for the preparation of individual, preselected halogensted diphenyls or diphenyl ethers which calls for the reaction of o-chlorophenol. l-chloro-2-nitrobenzene and potassium hydroxide to form 2-chlorophenyl 2-nitxophenyl ether. This product is then reduced to 2-chlorophenyl 2-amlnophenyl ether. The latter ether must be diazotlzed, after which the diazonium salt is finally converted to the desired bis (2-chlorophenyl) ether,
3.068.297 December 11. 1962 Harold I. Weingarten Monsanto Chemical Company ISOMERIZATION OF HALOBIPHENYLS
The invention relates to an improved process for effecting the conversion of by-product hologenated biphenyls to more useful liquid dielectric compositions having an improved dielectric constant. The by-product dihelogenated biphenyl compositions, particularly those rich in 2, 2'-dlhaloblphenyl can be lsomerlzed in the presence of aluminum chloride and anhydrous hydrogen chloride at temper atures from about 50C., to about 250C. and more preferable still from about 70C. for a time of from about 15 minutes to about 10 hours or more and preferable from about 1 hour to about 5 hours.
3.029.295 April 10. 1962 Robert Thermet and Ludovlc Parvi Soclete d'Electro-Chimie d'Electro-Metallurgic et des Aclerlea Electriques d'Ugine PREPARATION OF POLYCHLORINATED DIPHENYL DERIVATIVES
A method of preparation, in a single stage of chlorinated diphenyl derivatives having a degree of chlorination up to 100% by passing a gaseous stream containing a chlorine gas ingredient and a diphenyl ingredient as essential ingredients through a fluldlztble bed of divided material, maintaining the temperature in the bed at a value of at least as high as the boiling point of a desired diphenyl derivative, and regulating the rate of throughflow of said gaseous stream so as to maintain said bed in a state of stationary dense fluidization. This Invention relates to a method of producing poly chlorinated diphenyl derivatives. and more specifically the higher chlorinated derivatives of diphenyl, such as decachlorodiphenyl and products of approaching composition.
HONS 209566
3.007,975 November 7, 1961 John T . .Maaaengale and Theodore H. Fairbanks American Viscose Corporation 4,4'BIS-(CHLOROMETHYL)-BIPHENYL
EXHIBIT IV (4) EPA
PATENT DIGEST (continued)
'
A process of preparing 4,4'-bls-(chloromethyl)-biphenyl which comprises reacting biphenyl, formaldehyde and hydrogen chloride in the presence of a catalyst system comprising zinc chloride and water in a weight ratio at the start of the reaction of about 1.5 to 4 parts of zinc chloride to 1 part of water and wherein said zinc chloride is present in a ratio of 1.2 to 2.55 moles of zinc chloride per mole of biphenyl present at the start of the reaction.
1,892,400 December 27, 1932 Russell L. Jenkins and Joseph A. Sikarski Swann Research, Inc. DIPHENYL RESIN AND METHOD OF PRODUCING THE SAME
This invention related to diphenyl resins, and in particular to a process by which resins having predetermined properties may be produced. Thlt process for the production of diphenyl by thermal synthesis, preheated benzol vapors are pumped through a bath of a molten salt or molten metal, such as lead, said bath being main tained at the diphenyl forming temperature of about 850C.
1,892,398 December 27, 1932 Ruasell L. Jenkins Swann Research, Inc. NONCRYSTALLINE HIGHLY CHLORINATED DIARYL RESIN
The invention relates to the production of non-crystslllne highly chlorinated diaryl resins wherein various percentages of complex high boiling compounds which are formed as a by-product in the thermal synthesis method of producing diphenyl are mixed with the diphenyl before chlorination. The diphenyl is separated from the product of the diphenyl reaction by distillation.
HONS 209567
EXHIBIT IV (5) EPA
PATENT DIGEST (continued)
1,882,387 December 27, 1832 Russell L. Jenkins Swann Research. Inc. PROCESS FOR THE PRODUCTION OF CHLORINATED DIARYLS
*
This invention relatea to a method for the production of chlorinated diary is and has for its object the provision of means whereby varying amounts of chlorine may be substituted in diphenyl, or other diaryls or substituted diaryls, to produce compounds having physical properties ranging all the way from light oils to solids or aemi-sollds at ordinary temperatures. In the process for the catalytic production of chlorinated diphenyl. inducing and maintaining a thermosyphonic flow of the reacting mass through the catalyst by means of the action of the presence of the catalyst.
HONS 209568
EXHIBIT V (1) EPA
PROCESS FLOW AND ENVIRONMENTAL CONTROLS AT MONSANTO'S SAUGET PLANT
1. Process Flow*
DISTILLED BIPHENYL-> REACTORS-WIOLDING AND----------- DISTILLATION-- HOLDING--> BLENDING AND
AND ANHYDROUS
NEUTRALIZATION
UNIT
TANKS
SHIPPING
CHLORINE
TANKS
. Biphenyl purity is controlled
. Batch or . Flexible, closed
cascade
tankage
. Gas fired
. Product . Dilution with
storage
chlorobenzenes
. Scrap iron catalyst
. Lime neutralization
. First cut is recycled to reactor
. Flexible closed tankage
. Drumming or tank car filling
. Heart cut is product
* Source: References 11, 38
. Heel cut is drummed,
diluted and incinerated
HONS 209569
EXHIBIT V (2) EPA
PROCESS FLOW AND ENVIRONMENTAL CONTROLS AT MONSANTO'S SAUGET PLANT (continued)
2. Environmental Controls**
Drainage is directed to trenches and piping, and then to one of two 3,000-gallon settling basins. Pads are curbed. This insures PCB containment in case of accidental spill or equipment failure.
When small quantities of PCB's are collected into the settling basins in the manufacturing area they are later pumped into drums, and eventually incinerated.
- In the incinerator area itself, drainage is directed to trenches and piping which flow into a 10,000-gallon basin.
- Recovered PCB's are periodically pumped to storage, or incinerated.
In the manufacturing area, rupture disc lines and atmospheric vents have been rerouted through catch tanks, or redirected to settling basins. This insures that if a rupture does occur, PCB's will be contained in a controlled area.
Nitrogen blanketing on storage tanks has been provided to eliminate . any "breathing" of the tanks and resultant PCB escape.
Mist eliminators have been installed in vapor lines.
HONS 209570
** Source: References 14, 36, 37
EXHIBIT V (3) EPA
PROCESS FLOW AND ENVIRONMENTAL CONTROLS AT MONSANTO'S SAUGET PLANT (continued)
Underground sewers have been replaced with aboveground sewers, and others repaired or combined, to enable monitoring of the effluent from the department. In addition, this prevents any unknown buildup of PCB's in the sewer systems or any contamination of PCB's Into other sewers.
Among the housekeeping responsibilities operators have assumed are these:
- All pumps are checked for leakage on every shift. Drip pans that collect leaks are emptied into scrap PCB drums.
- All leaks are reported and documented so that corrections can be made and settling basins observed.
- "Floor Dry" is used to absorb any liquid PCB's that have spilled or leaked. If it becomes necessary to flush PCB's to the settling basin, a minimum amount of water is used.
.
- Sampling drums and scrap-PCB drums are quickly palletized, labeled, and transferred to the incineration area.
HONS 209571
EXHIBIT V (4) EPA
PROCESS FLOW AND ENVIRONMENTAL CONTROLS AT MONSANTO'S SAUGET PLANT (continued)
Systems to monitor effluent have been developed - PCB content In the parts-per-billion range can be determined. - The minimum detection level in wastewater is 100 ppb + 25%. - Monitoring is continuous. Loading and shipping safeguards have been established to minimize accidental PCB loss during transportation. Specific written instruc tions are on every container shipped.
HONS 209572
Freight Classification Aroclor 1221, 1232, 1242, 1248, 1254, 1260, 1262
Rail Classification Aroclor 1268, 4465, 5442, 5460
Truck Classification Aroclor 1268 Aroclor 4465, 5442, 5460
Standard Containers Aroclor 1221
Aroclor 1232
Aroclor 1242,1248, 1254. 1260, 1262
Aroclor 1288
Aroclor 4465 Aroclor 5442 Aroclor 5460 (flaked)
EXHIBIT VI EFA
SHIPPING OF AROCLOR PLASTICIZER! (47)
Synthetic Resin,-Liquid, NOIBN
Synthetic Resin, Other Than Liquid, NOIBN
Synthetic Resin, Powder, NOI Synthetic Resin. Lumps or
Solid Mass, NOI
Tank car, 520 lb. eteel drum, 50 lb. can Tank car, 550 lb. steel drum, 50 lb. can Tank car, 600 lb. steel drum, 50 lb. can 200 lb. fiber drum, 25 lb. fiber drum 500 lb. steel drum, 50 lb. can 450 lb- steel drum, 50 lb. can 50 lb. bag
HONS 209573
EXHIBIT VII (I) EPA
EXAMPLE OF CURRENT AROCLOR LABELING PRACTICE
lonsantoDIELECTRIC FLUID BY
lateral non KopUntenn buMiiNMi M
IIdcaufuiMDl iMKftn
<^\>
CAUTION!
CONTAINS CHLORINATED HYDROCARBONS
Read and follow all IMPORTANT safeguard instructions shown on this container.
WASTE DISPOSAL
INIi prior Monsanto notification used poiycMarinated biphenyl fluids may be returned freight pre paid for proper indntration at 3< per pound.
Ship to: Supervisor Dept 831 MONSANTO COMPANY SAUGET, ILLINOIS 62201
MONSAffTO COMPANY, ST. LOUIS, MISSOURI 63166, USA
811.03-280.19/53
HONS 209574
EXHIBIT Vn (2) EFA
EXAMPLE OF CURRENT AROCLOR LABELING PRACTICE
ENGLISH IMPORTANT
CHLORODIPHENYLS(42 V. - 54 V.) (or60 */.) (PCB)
This product contains POLYCHLORINATED BIPHENYL S (PCB's) which some studies have shown may be
persistent, an environmental contaminant and, possibly, Injurious to certain forms of bird, aquatic and animal
life.
PREVENT ANY ENTRY INTO THE ENVIRONMENT THROUGH SPILLS, LEAKAGE, DISPOSAL.
VAPOURISATION, RE-USE OF CONTAINERS OR OTHERWISE,
SPILLS, LEAKAGES AND WASTE PRODUCT MUST BE COLLECTED.
Use of this product musl be restricted to applications which can be controlled so that entry into the
environment does not occur and to applications in which it cannot come into contact with food, animal
feedstuffs or pharmaceuticals.
.
HARMFUL SUBSTANCE IF TAKEN INTERNALLY OR IF IN PROLONGED CONTACT WITH THE SKIN.
CAUSES IRRITATION OF SKIN AND EYES.
DURING SHIPMENT AVOID SPILLS AND LEAKAGE INTO INLAND WATERWAYS AND THE SEA.
Store away from food, animal feedstuffs and pharmaceuticals.
Keep container tightly closed.
,
.
Do not eat or smoke when using.
-
Avoid brealhing vapours, mist or fumes.
Do not wear contaminated clothing.
Wash product from skin with soap and water.
Wash eyes by flushing with water.
THIS COPY, THIS SIZE, IN SEVEN LANGUAGES IS PAINTED ON 30 AND 55 GALLON DRUMS USED FOR PCB SHIPMENTS.
Rons 209575
EXHIBIT VIU (1) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS
SECTION 2 CAPACITOR GUIDELINES
I. INTRODUCTION
There are two general classes of askarals used by the electrical industry. The higher chlorinated grades are the more persistent In nature. Because of their high degree of nonflammability, they are used in transformers where personnel safety is of paramount importance.
Capscltor-grade askarel has a lower degree of chlorination (cooposed primarily of the 3-chlorlne lsomsrs of biphenyl) and a higher degree of biodegradability. It is used in capacitors where the extreme degree of nonflammability required in transformers is of less importance.
II. CAPACITOR-CRAPE ASKAREL
In September of 1871, a new grade of capacitor lmpregnant, Aroclor 1018. was made available to the Industry. This new grade contains a typical concentration of 0.4 percent by weight of the higher boilings homologs of the chlorinated biphenyls. Aroclor 1018 replaces Aroclor 1242 which previously was the major capacitor lmpregnant and contained around 7 percent of the higher boiling homologa (the more persistent in nature). This 0.4 percent level of the higher boiling homologa should be the maximum concentration acceptable in any cap acitor lmpregnant, Aroclor 1242 and 1254, previously used as irapregnants, do not meet this requirement and should no longer be used in capacitors designed and manufactured for alternating-current applic ations,
Aroclor 1016 has the same UL nonflammability rating as Aroclor 1242.
Excerpts From The National Electrical Manufacturers Association (NEMA) Official Standards Proposal (16) For Handling And Disposal Of Capacitor And Transformer-Grade Askarels Containing FCBs.
HONS 209576
EXHIBIT VIII (2) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
PLANT HOUSEKEEPING AND EMPLOYEE SAFETY
A. Material
Aekarai for use in capacitors should consist of homologs and isomers of chlorinated biphenyl with the concentration of the higher boiling homologs at about 0.4 percent.* Arodor 1018 is consldsred to be the standard lmpregnant meeting these require ments.
Commonly used eolvents Include benzene, kerosene, acetone, trlchloroethane, trichloroethylene and perchloroethylene. Typical vapor pressure data for Aroclor 1018 are:
0C 25C 150C 200C
* 0.001 mm = 0.008 mm = 4.3 mm - 28.0 mm
At 25C and 760 mm Hg pressure, saturated air contains approximately 0.09 mg/liter.
1 mg/liter
= 90.0 ppm (v/v)
1 ppm (v/v)
= 0.011 mg/liter
B. Bulk Fluid Shipment, Receiving, and Transfer
Shipment of askarel from point of manufacture to point of receiving should be done in closed containers such as rail, tank cars, truck tanks, marine or barge tanks, or sealed drums. Con tainers should be labeled as to contents and carry a label cautioning against loss of fluid to the open environment. Containers used to transport asksrel should not be used for storage or to transport other material without being completely cleaned of all traces of askarel.
Monsanto Method T-02302
HONS 209577
EXHIBIT VIII (3) EPA
EXCERPTS FROM NEMA'S PROPOSED ENVIRONMENTAL CONTROLS (continued)
(Cleaning procedures must take cognizance of precautions against excessive exposure and of the need for propel disposal of contaminated cleansing solvents and materials). Transfer from shipping containers to processing systems should be through closed piping or tubing with appropriate valves, pumps, etc. Provision should be made for trapping and disposing of fluid lost by leakage or spills from the transfer system and from the storage containers.
Drums to be retired from use should be cleaned before crushing, delivery to scrap dealers, or other disposal. Contaminated cleaning fluids and materials should be disposed of as lndicatsd in Part V.
C. General Safety Precautions
1. Vapors
Breathing vapor or fumes from heated askarel ahould be
avoided. Provisions should be made for adequate ventilation
and regulation of manufacturing operations to avoid open ex
posure to askarel (especially at S5c or higher). Ths gases
produced when askarel Is decomposed by very high temperatures
(such as that of an electric arc) in the presence of air or organic
insulating materials contain a high percentage of hydrogen chloride,
and amall percentages of carbon dioxide, carbon monoxide and
oxygen. Minute concentrations of this combination of gasee are
very unpleasant and Irritating, thus giving ample warning of
their presence. If exposure to high concentrations of askarel
.
is necessary tinder emergency conditions, an approved gas mask
or self-contained breathing apparatus should be worn. Such
exposure should be under the surveillance of other personnel
capable of rescue In case of sn accident. If the odor of askarel
Is detected by the person wearing protective equipment, he should
Immediately go Into fresh air. All gas masks, respirators snd re
placement parts should have Bureau of Mines approval and be
maintained on a regular schedule In accordance with the manu
facturer's recommendation.
HONS 209578