Document DG8B8Qg4NdKpdLXB8X2NQ48a4

72 CHAPTER 4 1957 Guide The curves in Fig. 4 may be approximated very closely by the empirical formula:1 /= r 0,..00005555^1 + /e ^20,000- + --10JY""JI 1 Equation 8 is applicable to all liquids, and to gases when the pressure loss is less than 10 percent of the initial pressure. When the loss in head is high, the formula to be used for gases is Pi1 -- pi flVf Pi* ffd Pin which may be arranged to give the loss in pressure, tt!\ s(13) -?v / flVJ ' (14) Fluid Flow 73 Table 1. Values of e fob Diffebent Kinds of Pipb Type op Pipe Smooth drawn tubing................... Commercial steel or wrought iron. . Asphalted cast-iron....................... Galvanized iron.............................. Cast-iron...................................... Wood stave...................... Concrete................................... Riveted steel............................ e 0.00015 n D004 1/. UWOi) U.UWO LO U.UUiJ V \J\JO 1>U If. uo i ms vaiue oi /vr,, may oe used in .Equation 10 for laminar flow, and in Equation 12 or Fig. 4 for turbulent flow. The error in the approximation is somewhat greater for laminar than, for turbulent flow. In the former case, the relative error may be as.much as 10 percent, while in the latter it almost always is less than 3 percent. FLOW OF COMPRESSIBLE FLUIDS In the flow of compressible 'fluids, the large density variations make impracticable the use of the Bernoulli equation, (Equation 7). In certain special cases, however, the exact equations for compressible flow may be stated. If flow occurs with no friction or other internal irreversibility, Equation 6 becomes Fig. 5. Comparison of Velocity Profiles fob 3 Different Reynolds Numbebs but fob Same Average Velocity Pressure Loss in Non-Circular Pipes The formulas for friction loss in pipes are based on the use of pipes of fj circular cross-section. The same' formulas may be extended to non- J^' circular sections, by suitable modification. In the basic formula, Equation ft 8,. the internal diameter d is to be replaced by the hydraulic diameter k dH defined by the equation: |v 4 X area of cross-section dH = wetted perimeter of cross-section (15) For. example, in a rectangular duct, 1 ft by 2 ft, the cross-section area j is 2- sq ft, and the perimeter 6 ft. Then the hydraulic diameter will be .J dH = (4 x 2)/6 = 1V ft. In the case of a round pipe, dH = ird (16) i In computing the Reynolds number, and from that the friction factor, the | hydraulic diameter is not to be used. A better approximate procedure | is to replace the length in the Reynolds number by the shortest dimension | plus one-fourth of the hydraulic diameter. Thus, in a duct of dimension I a x b where a < b, Nn,, lr the purposes of calculating friction factors, is| NB. = (a + 0.25dH)Fp/p (17) | If, in addition, the flow is adiabatic, VP * = Pin' so that Equation 18 becomes or by integration,. 1- dp*+2! pi pyi (19) (20) , (21) This extension to compressible flow of Bernoulli's equation reduces to the more familiar form if the pressure change is small. The ratio of specific heats, fc, is used extensively in fluid dynamics; values of k for various gases are given in Table 2. Table 2. Ratio of Specific Heat at Constant Pressube to Specific Heat at Constant. Volume fob Compressible Fluids Compressible Fluid Helium and other monatomic gases Air and other diatomic gases AAmmmmoomnioa _a--__n__dJ h^- yWd*vrvo/>gueion gaaea.........................-................................................... sulfide........................ * * v ' VOQT_' Carbon dioxide, methane, natural gas, superheated steam, Sumlfouirstdisotexiadme, deothwynletnoea, aqcueatyliletyneo.f..9..7...p..e..r.c..e...n..t............................................ Ratio i = cp/cT 1.66 1.40 1.34 1.28 to 1.32 1.24 to 1.26